In addition to precise 3D coordinates, most light detection and ranging (LIDAR) systems also record “intensity”, loosely defined as the strength of the backscattered echo for each measured point. To date, LIDAR intensity data have proven beneficial in a wide range of applications because they are related to surface parameters, such as reflectance. While numerous procedures have been introduced in the scientific literature, and even commercial software, to enhance the utility of intensity data through a variety of “normalization”, “correction”, or “calibration” techniques, the current situation is complicated by a lack of standardization, as well as confusing, inconsistent use of terminology. In this paper, we first provide an overview of basic principles of LIDAR intensity measurements and applications utilizing intensity information from terrestrial, airborne topographic, and airborne bathymetric LIDAR. Next, we review effective parameters on intensity measurements, basic theory, and current intensity processing methods. We define terminology adopted from the most commonly-used conventions based on a review of current literature. Finally, we identify topics in need of further research. Ultimately, the presented information helps lay the foundation for future standards and specifications for LIDAR radiometric calibration. View Full-Text
Keywords: LIDAR; laser scanning; intensity; normalization; correction; calibration; radiometric LIDAR; laser scanning; intensity; normalization; correction; calibration; radiometric
Show Figures

Figure 1

MDPI and ACS Style

Kashani, A.G.; Olsen, M.J.; Parrish, C.E.; Wilson, N. A Review of LIDAR Radiometric Processing: From Ad Hoc Intensity Correction to Rigorous Radiometric Calibration. Sensors 2015, 15, 28099-28128. https://0-doi-org.brum.beds.ac.uk/10.3390/s151128099

AMA Style

Kashani AG, Olsen MJ, Parrish CE, Wilson N. A Review of LIDAR Radiometric Processing: From Ad Hoc Intensity Correction to Rigorous Radiometric Calibration. Sensors. 2015; 15(11):28099-28128. https://0-doi-org.brum.beds.ac.uk/10.3390/s151128099

Chicago/Turabian Style

Kashani, Alireza G., Michael J. Olsen, Christopher E. Parrish, and Nicholas Wilson. 2015. "A Review of LIDAR Radiometric Processing: From Ad Hoc Intensity Correction to Rigorous Radiometric Calibration" Sensors 15, no. 11: 28099-28128. https://0-doi-org.brum.beds.ac.uk/10.3390/s151128099

Find Other Styles

Article Access Map by Country/Region

1
Only visits after 24 November 2015 are recorded.
Back to TopTop