Next Article in Journal
Examining Negative Emotional Symptoms and Psychological Wellbeing of Australian Sport Officials
Previous Article in Journal
Effects of Pre-Workout Multi-Ingredient Supplement on Anaerobic Performance: Randomized Double-Blind Crossover Study
Previous Article in Special Issue
Quality Assessment of Three Types of Drinking Water Sources in Guinea-Bissau
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Behavior of Pseudomonas aeruginosa and Enterobacter aerogenes in Water from Filter Jugs

1
Department of Environment and Health, Italian National Institute of Health, 00161 Rome, Italy
2
Department of Biomedical, Metabolic and Neural Sciences, Section of Public Health, University of Modena and Reggio Emilia, 41125 Modena, Italy
3
Department of Public Health and Infectious Diseases, Microbiology Section, “Sapienza” University of Rome, 00161 Rome, Italy
*
Author to whom correspondence should be addressed.
Int. J. Environ. Res. Public Health 2020, 17(21), 8263; https://0-doi-org.brum.beds.ac.uk/10.3390/ijerph17218263
Submission received: 28 September 2020 / Revised: 31 October 2020 / Accepted: 5 November 2020 / Published: 9 November 2020

Abstract

:
Careless use conditions of filter jugs were applied to simulate and evaluate the behavior of two ubiquitous aquatic bacterial species, Pseudomonas aeruginosa and Enterobacter aerogenes. According to a reference protocol, nine different jugs of popular brands sold in the Italian market were used for the test. Separately, a suspension of the two bacteria was spiked in water used for filling the jugs. The concentration of the test organisms and total aerobic microbial count (TAMC) was measured daily in the filtered water along a period corresponding to the cartridge lifetime. Results showed a different trend of bacterial behavior. E. aerogenes was detectable exclusively on the first day after jug filling, while P. aeruginosa confirmed its persistence over time in all the jugs and its ability to potentially colonize surfaces and cartridges. The TAMC was detected at a concentration range from 102 to 107 CFU/100 mL in all the tests, high values that were not far from those raised in bottled flat natural mineral water weeks after bottling.

1. Introduction

In recent years, there has been an increasing demand for various household water treatment devices in European markets. Filter jugs have become alternatives to natural mineral water [1]. Water filter jugs are household water treatment devices not connected to the drinking water (DW) supply system. They are meant to be used exclusively with DW and therefore are not designed to make non-potable water potable. The improvement of the organoleptic properties of water (chlorine taste in particular) and the removal of limescale, hardness and certain metals such as lead are some of the claims made by manufacturers regarding water filter jugs [2]. Jugs employ spare cartridges that typically contain a granular mixture of ion-exchange resin and activated carbon. The resin determines the partial softening of water, while the activated carbon removes chlorine and some organic compounds. In some cases, cartridges have a silver-based compound with bactericidal properties, tending to lose their filtering capacity according to the volume of treated water and contact time with water. The cartridge lifetime is given by the manufacturers, generally corresponding to one month [3].
Some consumers show scarce confidence in tap water quality, often due to a perception of unpleasant tastes (e.g., residual chlorine). For this reason, they are able to consume natural mineral water or filtered water if they prefer [4], despite the well-consolidated European Directives [5,6] defining the criteria, parameters and values for evaluating water characteristics, guaranteeing appropriate hygienic quality. In Italy, guidelines for household water treatments are published in accordance with the Italian Decree of the Ministry of Health 25/2012 [7].
The World Health Organization has stated that “water entering the distribution system must be microbially safe and ideally should also be biologically stable” [8]. The “biological stability” requirement is scarcely defined in terms of what it actually means and how it can be achieved. Intuitively, biological stability would mean no changes occurring in the concentrations and composition of the microbial community in the water during distribution [9]. The production and distribution of biologically stable drinking water should be a priority not only for water suppliers but also for producers and users of household equipment for the treatment of drinking water. Consumers should be aware of water changes that could affect microbiological quality according to the treatment and the conservation of water in a filter pitcher.
Drinking water treatments ensure a high-quality finished product through a combination of processes aimed at removing chemical and microbiological contaminants. Drinking water is characterized by large biodiversity and conditions favoring mainly the survival of environmental microorganisms able to form biofilms. Bacterial growth is generally positively influenced by higher water temperatures, lower chlorine residuals and oligotrophy [10]. A core bacterial community can be easily observed in water and biofilms along a drinking water distribution system, independently of the water supply characteristics. Gram-negative aerobic bacteria belonging to genera Pseudomonas, Acinetobacter and other related genera usually prevail. Members of the genera Klebsiella, Enterobacter and Citrobacter, belonging to the coliform group, can be isolated at variable concentrations and successfully colonize water systems [11].
Pseudomonas aeruginosa is an opportunistic environmental pathogen characterized by a high degree of adaptability, capable of growing in oligotrophic waters and surviving in disinfected water. It is easily detectable in water stagnation conditions [12] and can colonize water storage tanks, faucet aerators and household devices for the treatment of drinking water [11]. Moreover, this bacterium is involved during the early stages of biofilm formation in plumbing systems due to the production of lipopolysaccharide and extracellular glycoproteins that can adhere to surfaces and facilitate the aggregation of microorganisms present in flowing water [13].
A large number of microbial cells is generally counted on surfaces in contact with drinking water [14]. Coliforms do not typically adhere first to water pipe surfaces; however, in the presence of an existing biofilm, they are able to remain attached and multiply [15].
Coliforms are used as microbial indicators for evaluating water quality and the efficiency of water treatments [16,17]. Belonging to the genus Enterobacter, coliforms have a strong potential for growth in aquatic environments, and drinking water can host the bacterium.
Several studies on the release of silver from pitcher filter cartridges have recently been performed [18,19], though specific controls and studies related to microbiological populations in filtered water are limited. No alerts involving water jugs have been reported via the Rapid Alert System for Food and Feed (RASFF) [20] and the Rapid Alert System for dangerous nonfood products (RAPEX) [21].
In this context, on a specific request of the Italian National Board of Health, an experimental protocol was implemented with the aim of evaluating the behavior of two ubiquitous bacterial species able to colonize surfaces: P. aeruginosa and Enterobacter aerogenes. The performance of the total aerobic microbial count (TAMC) at room temperature (around 20 °C) was taken into account.

2. Materials and Methods

A water filter jug comprises a container (jug), funnel, cartridge with an active filtering medium, lid and, often, a cartridge exchange indicator.
Tests were carried out on nine filter jugs of popular brands present in the Italian retail market. Water filter jug containers are made of styrene–acrylonitrile copolymers. Filtering cartridges comprise a polypropylene (PP) housing, a polyethylene terephthalate (PET) screen located inside the cartridge intended to prevent the release of filter medium particles and a filter medium comprising ion-exchange resin(s) and activated carbon. The entire filter medium or only the activated carbon is usually treated with silver. All the filter cartridges tested had a similar structure and composition with a mixture of granular silver-modified activated carbon and weak-base ion-exchange resins as the filtration matrix. The filter capacity of the water jugs ranged from 1.2 to 1.6 L, while their nominal capacity ranged from 120 to 150 L.

2.1. Contact Test Protocol

The validated test protocol was performed to simulate incorrect conditions of the use of filter jugs, providing the “worst case” in their management. The test period for each jug was 5 weeks in order to use 125% of the claimed cartridge capacity corresponding to the maximum treatable water volume. The test filters were set-up according to the manufacturers’ instructions for use.
After the first week of conditioning with drinking water, each pitcher was subjected to (intradaily and interdaily) contact cycles with tap water, except for the first day of each week, when they were filled with artificially contaminated water (spiked water). The spiked water consisted of tap water with sodium thiosulfate (1 mL/L of a solution at 10% w/v) added with one of the tested microorganisms. The filter pitchers were separately tested for the colonization ability of each microorganism. Contemporaneously, the spiked water was used as a positive control of bacteria vitality, and its bacterial concentrations were monitored in parallel with the jug-filtered water for the whole testing period. Positive controls were stored in the same conditions as water from the filter jugs.
Each intradaily contact cycle consisted of 4 consecutive contact tests, each including water filling, stagnation (30 min) and emptying. All water derived from the 4 intradaily emptying steps was collected in a single sterile container (intradaily composite sample) and mixed. During the interdaily contact cycle, jugs were kept in darkness at room temperature and the filtering cartridge remained in contact with water until the next day when the water derived from its emptying (interdaily water sample) was analyzed. This series of cycles was repeated for the first 5 days of each week followed by a stagnation period of 48 h (interweekly break). During stagnation, the tested pitcher remained in contact with the last filling water of the fifth day and the jug was kept in darkness at room temperature until the first day of the following week when the jug was emptied and the water was analyzed (interweek water sample). The whole process was replicated for 4 weeks for each jug.

2.2. Sampling and Analysis

For each jug, water was sampled and analyzed as follows:
-
Five days a week for 4 weeks, 300 mL were collected from the intradaily composite sample after mixing for the analysis of E. aerogenes or P. aeruginosa (100 mL in triplicate); 3 mL was also collected and analyzed for TAMC (1 mL in triplicate);
-
Four days a week for 4 weeks, 300 mL were collected from the interdaily water sample after mixing for the analysis of E. aerogenes or P. aeruginosa (100 mL in triplicate); 3 mL was also collected and analyzed for TAMC (1 mL in triplicate);
-
Once a week for 4 weeks, 300 mL were collected from the interweekly water sample after mixing for the analysis of E. aerogenes or P. aeruginosa (100 mL in triplicate); 3 mL was also collected and analyzed for TAMC (1 mL in triplicate);
-
Five days a week for 4 weeks, positive controls were tested for E. aerogenes or P. aeruginosa (1 mL in triplicate).

2.3. Tested Microorganisms

E. aerogenes (ATCC 13048, Biogenetics Diagnostics, Padua, Italy) and P. aeruginosa (ATCC 9027, Biogenetics Diagnostics, Padua, Italy) were the bacteria used for contact tests. They were added to spike water at a concentration ranging from 20 to 100 CFU/100 mL. The bacteria were added to jug filters one by one.

2.4. Microbiological Methods

E. aerogenes and P. aeruginosa were detected and enumerated in jug water samples and positive controls by standard miniaturized most probable number (MPN) methods (ISO 9308-2:2012 or Colilert 18/Quanti-Tray IDEXX test and ISO 16266-2:2018 or Pseudalert/Quanti-Tray IDEXX test, respectively) [22,23]. Analyzed samples were incubated at 36 ± 1 °C for 18 and 24 h, respectively. Results were expressed in MPN/100 mL. Both tests, designed on statistical criteria, are based on a bacterial enzyme detection technology that signals the presence of target bacteria through the hydrolysis of chromogenic or fluorogenic substrates incorporated into culture media.
TAMC was also simultaneously investigated. Water samples were analyzed by a pour plating technique on Water Plate Count (WPC, Thermo Fisher Scientific, Milano, Italy) according to ISO 6222:1999 [24]. WPC plates were incubated at 25 °C for 7 days. Results were expressed in CFU/mL.
Analysis of TAMC at 25 °C was also performed on tap water used for filling filter jugs.

2.5. Data Analysis

At each time, the analysis was performed in triplicate and the obtained values were averaged. The standard deviation (DS) was also calculated. Data were elaborated by analysis of variance (ANOVA) with the Bonferroni test. All statistical analyses were performed with software package IBM SPSS statistics, version 22 (IBM Corporation, Armonk, NY, USA).

3. Results

3.1. Enterobacter Aerogenes

E. aerogenes concentrations in the intradaily composite samples have similar values in all nine examined jugs, ranging from 0 to 102 MPN/100 mL, without any statistically significant differences. The microbial load was detectable exclusively on the first day of each week. In the subsequent days, the concentration values generally remained below the limit of detection. This trend was repeated and observed in all the nine tested pitchers (Figure 1, Figure 2 and Figure 3). Similarly, in the water samples of the interdaily pause, the bacterial concentrations were detectable exclusively after the first break of each week. In the subsequent days, the results showed similar values compared to the intradaily composite samples, generally with lower values or below the limit of detection (Table 1).
After the four interweekly breaks, there were no positive samples for all the pitchers, with the only exception of one water sample collected from Pitcher 3 (E. aerogenes, 8.6 MPN/100 mL) (Table 1).
Moreover, the concentration of E. aerogenes in the spiked control water showed a low increase (2.7–5.3 times compared to the initial counts) over the first 3–4 weeks, with a 53–91% bacterial load reduction at the end of the whole testing period.

3.2. Pseudomonas aeruginosa

P. aeruginosa concentration in the intradaily composite samples showed different trends in the nine filter jugs (Figure 1, Figure 2 and Figure 3). The ANOVA test showed a global statistically significant difference among the nine filter jugs (p < 0.001). P. aeruginosa concentrations resulted significantly higher in filter jugs 1 and 2 followed by the others jugs (p < 0.001, Pitcher 1 vs. Pitchers 3–9; p < 0.001, Pitcher 2 vs. Pitchers 3–9), while no significant differences in P. aeruginosa concentration were detected between Pitchers 1 and 2). The composite samples of Pitcher 1 showed a progressive increase in concentration starting from the first bacterial inoculum until half of the third week, with a maximum value of 1.9 × 103 MPN/100 mL. More stable values were observed over the following weeks (Figure 1). Water from Pitcher 2 showed the highest bacterial load (maximum of 7.5 × 104 MPN/100 mL). In this pitcher, the bacterium concentration tended to increase over the first two weeks, remaining at a constant concentration in the last two weeks (Figure 1). Pitchers 3 and 4 displayed a similar trend with a negligible concentration or no presence of bacterium until the third and fourth weeks, respectively (Figure 1 and Figure 2). P. aeruginosa was detected only on the first day of each week when the pitcher was filled with the spiked water, and a slight increase was detected only in the last week. In Pitchers 5 and 6, low concentrations, mainly below the limit of detection, were maintained for the first two weeks, except for the first day of each week. In the last two weeks, concentrations of both of the pitchers showed a small increase (Figure 2). In the remaining pitchers (Pitchers 7–9), daily composites showed a detectable bacterial load exclusively on the first day of each week due to the filling with spiked water. This trend remained constant over the entire test period (Figure 3).
Water from Pitchers 1 and 2 after the interdaily break (Table 2) had higher bacterium loads compared to the composite samples (maximum of 1.6 × 104 MPN/100 mL and 2.2 × 106 MPN/100 mL, respectively). After the interdaily break, water from Pitchers 3 and 4 showed a trend similar to the respective composites during the first three weeks. In the last week, an increase was shown, with a maximum value of 2 × 102 MPN/100 mL for Pitcher 3 and 3.3 × 102 MPN/100 mL for Pitcher 4. In the case of Pitchers 5 and 6, the results of the interdaily samples showed a trend similar to their intradaily composites, with maximum values of 1.4 × 102 and 2 × 102 MPN/100 mL, respectively. Finally, for Pitchers 7–9 after the interdaily pause, the concentrations were low and detectable only after the break of the first day of the week (Table 2).
After the interweekly break, water samples collected from Pitchers 1 and 2 showed a trend similar to the interdaily samples with generally higher values. Water from Pitchers 3–6 had no positive results until the first two weekly breaks, while low concentrations were observed in the next two interweekly breaks. Water samples from Pitchers 7–9 showed no positive changes over all the four interweekly breaks (Table 2). In the P. aeruginosa-spiked water control, the bacterial concentrations showed an almost constant growth rate over the whole testing period, with a concentration rise of 5–6 orders of magnitude and high bacterial load until the end of the test (mean value: 106 MPN/100 mL).

3.3. Total Aerobic Microbial Count at Room Temperature

For the TAMC, water samples from the nine pitchers showed the same growth trend over the entire period (Figure 1, Figure 2 and Figure 3): bacterial concentrations had a gradual increase during the five weeks, reaching concentrations of 106–107 CFU/100 mL. As observable in Figure 1, Figure 2 and Figure 3, the concentrations stabilized over time.

4. Discussion

Few studies have been conducted on the bacteriological characteristics of filtered water [25,26]. All the studies were carried out in strict compliance with the conditions of use recommended by the supplier (water periodically renewed three times a week and filtered water stored at 4 °C). The findings showed the maintenance of the microbiological quality of filtered water when there was refrigeration during the residence of water in jugs. This means that refrigeration of the jug containing the filtered water can help significantly delay the development of bacterial flora in water over time. Conversely, when jugs containing the filtered water were kept at room temperature and water was not renewed, the highest growth rates for culturable aerobic bacteria could be found. A study showed no detection of the standard indicators of fecal contamination (E. coli and enterococci) in filtered water [2].
Our study investigated two bacteria, one recognized as a good biofilm colonizer and the other less likely to form biofilms. The study was deliberately carried out by keeping the selected jugs under inappropriate conditions and simulating the worst-case scenario.
The data showed different trends of behavior for the two selected bacteria. In the nine pitchers, E. aerogenes proved its low ability to persist. Its concentrations decreased immediately after the inoculation day to values below the detection limit. This trend could be attributed to the inability of E. aerogenes to adhere to surfaces and persist in biofilms, although many genera of coliform bacteria are able to colonize granular-activated carbon filters [15,27].
P. aeruginosa is recognized as a good colonizer, able to survive in water and biofilms in poor environmental conditions (e.g., oligotrophy, different range of pH, high and low temperatures). Based on the P. aeruginosa concentration trend, the pitchers were divided into three different groups. In the first group (Pitchers 1 and 2), the microorganism was present in the filtered water, likely colonizing filters and internal surfaces, from the first week, increasing its concentration in water throughout the study period. In the second group (Pitchers 3–6), P. aeruginosa was found within the filtered water of Pitchers 3–6 only at the end of the study period, probably due to slower colonization of cartridges and surface. In the remaining pitchers (Pitchers 7–9), the water did not contain Pseudomonas other than after each filling.
Interestingly, all the selected jugs had filter cartridges with a silver-based compound. However, the filtered water had different quality characteristics with regard to Pseudomonas. It is conceivable that some jugs had a greater tendency to favor the Pseudomonas colonization of filters and surfaces.
The antimicrobial activity of the silver ion is widely used to control bacterial growth in a variety of medical applications and drinking water for disinfection purposes [28]. The efficacy of the water disinfection process depends mainly on Ag ion concentrations, contact time and specific microbial characteristics. In a study on the efficacy of silver ions (up to 100 μg/L) against P. aeruginosa in synthetic drinking water, the authors found a 4-log reduction of P. aeruginosa after a three-hour contact time [29]. A 5-log reduction in P. aeruginosa was similarly observed after a 12 h contact time, with 80 μg/L Ag, against 3 × 106 CFU/mL of P. aeruginosa. Based on these data, it is presumable that the c × t value available in the colonized cartridges’ effluents was not high enough to ensure an efficacy action by Ag ions. The exclusive conformation, as well as the porosity of the filters, could have differently supported the biofilm formation and consequently the growth of P. aeruginosa. A reduced efficacy of Ag ions on biofilm bacteria has been reported by Silvestry-Rodriguez et al., who found that silver (100 μg/L) was ineffective in reducing biofilm formation in drinking water distribution systems [30]. Data obtained from chemical analyses carried out in parallel with our microbiological analyses on the same jugs and water showed variable concentrations of silver with values ranging from 17 to 39 µg/L (≤1 µg/L in the initial water) [31]. The data confirm the ability of P. aeruginosa to adapt to oligotrophic environmental conditions, typical of many drinking water systems, and to persist and multiply in biofilm over a long period [32,33].
Studies performed on healthy human volunteers observed that colonization by P. aeruginosa (not the disease) of subjects required an oral dose of more than 1.5 million bacteria, demonstrating that P. aeruginosa generally does not infect healthy organisms, while immunocompromised persons are certainly more at risk [34,35]. The ingestion of water containing P. aeruginosa can be considered a risk for deeply immunocompromised individuals and does not seem to be a risk for the general population. The infectious dose for healthy individuals has been calculated to be in a range between 106 and 1010 CFU/mL, which, considering the pathogenic opportunistic nature of the bacterium, may become much lower in the case of immunocompromised individuals [36]. Therefore, the ascertained ability of P. aeruginosa to colonize some of the jug filters tested makes the use of water jugs a condition of risk for vulnerable population groups considering the lower infectious dose for immunosuppressed individuals.
In filtered water from all the pitchers, the TAMC was detected at concentrations ranging from 102 to 107 CFU/100 mL. Water stagnation in all the jugs caused a general deterioration of the microbiological quality with a gradual but constant increase over time. The TAMC, as a microbiological parameter, has little value as an indicator of pathogen presence [11]. In fact, most of the microorganisms growing under the term TAMC generally include members of the natural (typically nonhazardous) microbiota of water and biofilm and, in some instances, organisms from diverse pollutant sources. In distribution systems, increasing numbers of TAMC can indicate a deterioration in cleanliness, possible stagnation phenomena and the potential development of biofilms. Under these experimental conditions, the TAMC concentration is comparable to those of water maintained in static conditions in containers or bottles [37]. The high concentrations reached in this study can be explained by an increase of vital bacteria into the biofilm with periodic detachment. It has been demonstrated that plastic materials can be colonized in higher densities compared to the total bacterial cell count grown on steel and copper in bank-filtered water [38]. The presence of activated carbon inside jug filters may contribute to the fast and increased colonization of bacteria. The biofilm on the granular carbon particles is described as a monolayer facilitating an intensive contact between microorganisms and substrates dissolved in water or fixed in carbon particle pores. The granular-activated carbon, used in the household treatment devices, permits the nutrients accumulation and neutralizes residues of disinfectants, providing an ideal environment for microbial growth and consequent worsening of the microbiological quality of water [11,39].
Interestingly, a study was conducted in order to examine the possible adverse effects of jug filters on water quality [26]. This study concluded that there was no evidence of microbiologically adverse effects related to the use of filter pitchers, even in test conditions that simulate possible contamination with pathogenic microorganisms (E. coli and Salmonella). In particular, Salmonella and E. coli deliberately spiked into the feed water did not survive in the filtered water or colonize the filter media. It was found that these organisms were only present, if at all, in the first filtrate following inoculation. The TAMC levels tended to be higher in filtered water compared to the feed, particularly with high-nutrient test water. There was no indication of an “explosion” in TAMC levels. Overall, this study concluded that there was no evidence that jug water filter systems have adverse effects on microbial water quality, even when tested under conditions simulating abuse and contamination. Similarly, our results do not indicate a real health risk in these experimental conditions; however, an increase of microbial concentration was observed for P. aeruginosa and TAMC.

5. Conclusions

Our results showed a different trend of bacterial behavior. In fact, the concentrations of P. aeruginosa and E. aerogenes varied according to the specific characteristics of each type of bacterium, more or less inclined to persist on surfaces and filter cartridges. The obtained data are encouraging because, despite simulated inappropriate management of the jugs, no serious health risk emerged, although an increase of concentrations was calculated for P. aeruginosa and TAMC. On the one hand, the TAMC showed a regular increase with a rise in the concentration of 3–4 order of magnitude during the five experimental weeks and, on the other hand, a concentration increase of P. aeruginosa, a recognized opportunistic pathogen.
Finally, further studies would be useful for investigating the possible formation of biofilm in the cartridges, and to check the effects on the filtering cartridges and filtered water in the presence of contemporary microbial contamination.

Author Contributions

Study conception and design, L.B.; Analysis and interpretation of data, R.B., S.P., M.S., and L.V.; Drafting of manuscript, R.B., and S.P.; Critical revision: L.B. All authors have read and agreed to the published version of the manuscript.

Funding

This study was financially supported by the Italian Ministry of Health through the CCM (Centro Nazionale per il Controllo delle Malattie e della Salute), Project: “Verification of devices for the treatment of drinking water.”

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Hug, M.; Xavie, G.; Domene, E.; Sauri, D. Tap water, bottled water or in-home water treatment. Systems: Insights on household perceptions and choices. Water 2020, 12, 1310. [Google Scholar] [CrossRef]
  2. French Agency for Food, Environmental and Occupational Health & Safety (ANSES). Opinion of the French Agency for Food, Environmental and Occupational Health & Safety on the Assessment of the Safety and Effectiveness of Water Filter Jugs; Opinion Request No 2015-SA-0083; French Agency for Food, Environmental and Occupational Health & Safety (ANSES): Maisons-Alfort, France, 2016. [Google Scholar]
  3. Information Note no. 2014-XXX (Communicable under the Act of 17 July 1978). Review of the TN 35EA Investigation Undertaken in the Fourth Quarter of 2012 Dealing with Domestic Household Treatment Devices: Water Filter Jugs and Permanent Filtration Facilities; 27 March 2014; Directorate General for Competition Policy, Consumer affairs and Fraud Control (DGCCRF)—Ministry of Economy and Finance France: Paris, France, 2014.
  4. Doria, M.F. Factors influencing public perception of drinking water quality. Water Policy 2010, 12, 1–19. [Google Scholar] [CrossRef]
  5. European Union. Council Directive 98/83/EC. On the Quality of Water Intended for Human Consumption. Off. J. Eur. Communities 1998, 330, 32–54. [Google Scholar]
  6. European Union. Commission Directive (EU) 2015/1787 of 6 October 2015 amending Annexes II and III to Council Directive 98/83/EC on the quality of water intended for human consumption. Off. J. Eur. Communities 2015, 260, 6–17. [Google Scholar]
  7. Disposizioni Tecniche Concernenti Apparecchiature Finalizzate al Trattamento dell’Acqua Destinata al Consumo Umano [Technical Provisions Concerning Equipment for the Treatment of Water Intended for Human Consumption]; Italian Decree of the Ministry of Health 25/2012; Gazzetta Ufficiale n. 69 del 22-3-2012; Ministry of Health: Rome, Italy, 2012.
  8. World Health Organization (WHO). Guidelines for Drinking Water Quality, 4th ed.; World Health Organization (WHO): Geneva, Switzerland, 2011; 541p. Available online: http://whqlibdoc.who.int/publications/2011/9789241548151eng.pdf (accessed on 20 September 2020).
  9. Lautenschlager, K.; Hwang, C.; Liu, W.T.; Boon, N.; Köster, O.; Vrouwenvelder, H.; Egli, T.; Hammes, F. A microbiology-based multi-parametric approach towards assessing biological stability in drinking water distribution networks. Water Res. 2013, 47, 3015–3025. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  10. Nescerecka, A.; Juhna, T.; Hammes, F. Identifying the underlying causes of biological instability in a full-scale drinking water supply system. Water Res. 2018, 135, 11–21. [Google Scholar] [CrossRef]
  11. Bartram, J.; Cotruvo, J.; Exner, M.; Fricker, C.; Glasmacher, A. Heterotrophic Plate Counts and Drinking-Water Safety: The Significance of HPCs for Water Quality and Human Health; WHO Emerging Issues in Water and Infectious Disease Series; IWA Publishing: London, UK, 2003. [Google Scholar] [CrossRef]
  12. Hambsch, B.; Sacre, C.; Wagner, I. Heterotrophic plate count and consumer’s health under special consideration of water softeners. Int. J. Food Microbiol. 2004, 92, 365–373. [Google Scholar] [CrossRef]
  13. Chang, C.Y. Surface sensing for biofilm formation in Pseudomonas aeruginosa. Front. Microbiol. 2017, 8, 2671. [Google Scholar] [CrossRef]
  14. Douterelo, I.; Sharpe, R.L.; Boxall, J.B. Influence of hydraulic regimes on bacterial community structure and composition in an experimental drinking water distribution system. Water Res. 2013, 47, 503–516. [Google Scholar] [CrossRef]
  15. Kilb, B.; Lange, B.; Schaule, G.; Flemming, H.C.; Wingender, J. Contamination of drinking water by coliforms from biofilms grown on rubber-coated valves. Int. J. Hyg. Environ. Health 2003, 206, 563–573. [Google Scholar] [CrossRef]
  16. Ashbolt, N.J.; Grabow, W.O.K.; Snozzi, M. Indicators of microbial water quality. In Water Quality—Guidelines, Standards and Health. Assessment of Risk and Risk Management for Water-Related Infectious Disease; Fewtrell, L., Bartram, J., Eds.; World Health Organization: Geneva, Switzerland, 2001; pp. 289–316. [Google Scholar]
  17. Bonadonna, L.; Ottaviani, M. Metodi Analitici di Riferimento per le Acque Destinate al Consumo Umano ai Sensi del DL.vo 31/2001. Metodi Microbiologici. Rapporti ISTISAN 07/5; Istituto Superiore di Sanità: Roma, Italia, 2007. [Google Scholar]
  18. Garboś, S.; Swięcicka, D. Silver migration from silver-modified activated carbon applied as a water filtration medium in classic cartridges of jug filter systems. Food Addit. Contam. Part A Chem. Anal. Control. Expo. Risk Assess. 2012, 29, 1810–1819. [Google Scholar] [CrossRef]
  19. Garboś, S.; Swiecicka, D. Human exposure to silver released from silver-modified activated carbon applied in the new type of jug filter systems. Rocz. Panstw. Zakl. Hig. 2013, 64, 1–6. [Google Scholar]
  20. RASFF (Rapid Alert System for Food and Feed). Available online: https://webgate.ec.europa.eu/rasff-window/portal/?event=SearchForm&cleanSearch=1# (accessed on 20 September 2020).
  21. RAPEX (Rapid Alert System for Dangerous Non-Food Products). Available online: http://ec.europa.eu/consumers/safety/rapex/alerts/main/index.cfm?event=main.search (accessed on 20 September 2020).
  22. Water quality—Enumeration of Escherichia Coli and Coliform Bacteria—Part 2: Most Probable Number Method; ISO 9308-2:2012; International Organization for Standardization (ISO): Geneva, Switzerland, 2012.
  23. Water Quality—Detection and Enumeration of Pseudomonas Aeruginosa—Part 2: Most Probable Number Method; ISO 16266-2:2018; International Organization for Standardization (ISO): Geneva, Switzerland, 2018.
  24. Water Quality—Enumeration of Culturable Micro-Organisms—Colony Count by Inoculation in a Nutrient Agar Culture Medium; ISO 6222:1999; International Organization for Standardization (ISO): Geneva, Switzerland, 1999.
  25. Daschner, F.D.; Rüden, H.; Simon, R.; Clotten, J. Microbiological contamination of drinking water in a commercial household water filter system. Eur. J. Clin. Microbiol. Infect. Dis. 1996, 15, 233–237. [Google Scholar] [CrossRef] [PubMed]
  26. Drinking Water Inspectorate. Assessment of the Effects of Jug Water Filters on the Quality of Public Water Supplies; Report n. DWI 6049/2; Drinking Water Inspectorate (DWI): England, UK, 2003. Available online: http://dwi.defra.gov.uk/research/completed-research/reports/DWI70-2-147.pdf (accessed on 20 September 2020).
  27. Camper, A.K.; LeChevallier, M.W.; Broadaway, S.C.; McFeters, G.A. Bacteria associated with granular activated carbon particles in drinking water. Appl. Environ. Microbiol. 1986, 52, 434–438. [Google Scholar] [CrossRef] [Green Version]
  28. Hwang, M.G.; Katayama, H.; Ohgaki, S. Inactivation of Legionella pneumophila and Pseudomonas aeruginosa: Evaluation of the bactericidal ability of silver cations. Water Res. 2007, 41, 4097–4104. [Google Scholar] [CrossRef]
  29. Huang, H.I.; Shih, H.Y.; Lee, C.M.; Yang, T.C.; Lay, J.J.; Lin, Y.E. In vitro efficacy of copper and silver ions in eradicating Pseudomonas aeruginosa, Stenotrophomonas maltophila and Acinetobacter baumannii: Implications for on-site disinfection for hospital infection control. Water Res. 2008, 42, 73–80. [Google Scholar] [CrossRef]
  30. Silvestry-Rodriguez, N.; Bright, K.R.; Uhlmann, D.R.; Slack, D.C.; Gerba, C.P. Inactivation of Pseudomonas aeruginosa and Aeromonas hydrophila by silver in tap water. J. Environ. Sci. Health A 2007, 42, 1579–1584. [Google Scholar] [CrossRef]
  31. Veschetti, E. Results of a recent survey of the use of jug water filters. In Proceedings of the 33rd ENDWARE Meeting, Gibraltar, 21–22 May 2013. [Google Scholar]
  32. Wingender, J.; Flemming, H.C. Biofilms in drinking water and their role as reservoir for pathogens. Int. J. Hyg. Environ. Health 2011, 214, 417–423. [Google Scholar] [CrossRef]
  33. Douterelo, I.; Jackson, M.; Solomon, C.; Boxall, J. Microbial analysis of in situ biofilm formation in drinking water distribution systems: Implications for monitoring and control of drinking water quality. Appl. Microbiol. Biotechnol. 2016, 100, 3301–3311. [Google Scholar] [CrossRef] [Green Version]
  34. Mena, K.D.; Gerba, C.P. Risk assessment of Pseudomonas aeruginosa in water. Rev. Environ. Contam. Toxicol. 2009, 201, 71–115. [Google Scholar] [CrossRef]
  35. Buck, A.C.; Cooke, E.M. The fate of ingested Pseudomonas aeruginosa in normal persons. J. Med. Microbiol. 1969, 2, 521–525. [Google Scholar] [CrossRef]
  36. Al-Hiyasat, A.S.; Ma’ayeh, S.Y.; Hindiyeh, M.Y.; Khader, Y.S. The presence of Pseudomonas aeruginosa in the dental unit waterline systems of teaching clinics Intern. J. Dent. Hyg. 2007, 5, 36–44. [Google Scholar] [CrossRef]
  37. Leclerc, H.; Moreau, A. Microbiological safety of natural mineral water. FEMS Microbiol. Rev. 2002, 26, 207–222. [Google Scholar] [CrossRef]
  38. Schwartz, T.; Hoffmann, S.; Obst, U. Formation and bacterial composition of young, natural biofilms obtained from public bank-filtered drinking water systems. Water Res. 1998, 32, 2787–2797. [Google Scholar] [CrossRef]
  39. Tobin, R.S.; Smith, D.K.; Lindsay, J.A. Effects of activated carbon and bacteriostatic filters on microbiological quality of drinking water. Appl. Environ. Microbiol. 1981, 41, 646–651. [Google Scholar] [CrossRef] [Green Version]
Figure 1. Bacterial concentration trends in daily composite samples in Filter Jugs 1–3. Arrows represent weekly inoculum for both bacteria (E. aerogenes and P. aeruginosa). The y-axes show: E. aerogenes and P. aeruginosa concentrations expressed in most probable number (MPN)/100 mL (left); total aerobic microbial count (TAMC) at 25 °C expressed in CFU/100 mL (right).
Figure 1. Bacterial concentration trends in daily composite samples in Filter Jugs 1–3. Arrows represent weekly inoculum for both bacteria (E. aerogenes and P. aeruginosa). The y-axes show: E. aerogenes and P. aeruginosa concentrations expressed in most probable number (MPN)/100 mL (left); total aerobic microbial count (TAMC) at 25 °C expressed in CFU/100 mL (right).
Ijerph 17 08263 g001
Figure 2. Bacterial concentration trends in daily composite samples in Filter Jugs 4–6. Arrows represent weekly inoculum for both bacteria (E. aerogenes and P. aeruginosa). The y-axes show: E. aerogenes and P. aeruginosa concentrations expressed in MPN/100 mL (left); TAMC at 25 °C expressed in CFU/100 mL (right).
Figure 2. Bacterial concentration trends in daily composite samples in Filter Jugs 4–6. Arrows represent weekly inoculum for both bacteria (E. aerogenes and P. aeruginosa). The y-axes show: E. aerogenes and P. aeruginosa concentrations expressed in MPN/100 mL (left); TAMC at 25 °C expressed in CFU/100 mL (right).
Ijerph 17 08263 g002
Figure 3. Bacterial concentration trends in daily composite samples in Filter Jugs 7–9. Arrows represent weekly inoculum for both bacteria (E. aerogenes and P. aeruginosa). The y-axes show: E. aerogenes and P. aeruginosa concentrations expressed in MPN/100 mL (left); TAMC at 25 °C expressed in CFU/100 mL (right).
Figure 3. Bacterial concentration trends in daily composite samples in Filter Jugs 7–9. Arrows represent weekly inoculum for both bacteria (E. aerogenes and P. aeruginosa). The y-axes show: E. aerogenes and P. aeruginosa concentrations expressed in MPN/100 mL (left); TAMC at 25 °C expressed in CFU/100 mL (right).
Ijerph 17 08263 g003
Table 1. E. aerogenes concentrations from interdaily and interweekly stagnation water (9 pitchers tested for 4 weeks).
Table 1. E. aerogenes concentrations from interdaily and interweekly stagnation water (9 pitchers tested for 4 weeks).
E. aerogenes
Pitcher (n.)
Interdaily Stagnation
(16 Per Pitcher) *
Interweekly Stagnation
(4 Per Pitcher) **
Mean ± SD
(min–max)
MPN/100 mL
Mean ± SD
(min–max)
MPN/100 mL
18.9 ± 2.1 × 1010
(0.0–7.8 × 101)(0.0–0.0)
26.0 ± 1.2 × 1010
(0.0–4.3 × 101)(0.0–0.0)
34.4 ± 7.92.2 ± 4.3
(0.0–2.9 × 101)(0.0–8.6)
44.6 × 101 ± 8.1 × 1010
(0.0–2.0 × 102)(0.0–0.0)
51.8 × 101 ± 3.9 × 1010
(0.0–1.3 × 102)(0.0–0.0)
61.2 × 101 ± 3.1 × 1010
(0.0–1.0 × 102)(0.0–0.0)
73.3 × 101 ± 6.3 × 1010
0.0–2.0 × 102(0.0–0.0)
81.6 × 101 ± 3.4 × 1010
0.0–1.0 × 102(0.0–0.0)
97.1 ± 1.5 × 1010
0.0–4.3 × 101(0.0–0.0)
* interdaily breaks are 16/pitcher and analyses were performed in triplicate (N = 48). ** interweekly breaks are 4/pitcher and analyses were performed in triplicate (N = 12). SD: standard deviation.
Table 2. P. aeruginosa concentrations from interdaily and interweekly stagnation water (9 pitchers tested for 4 weeks).
Table 2. P. aeruginosa concentrations from interdaily and interweekly stagnation water (9 pitchers tested for 4 weeks).
P. aeruginosa
Pitcher (n.)
Interdaily Stagnation
(16 Per Pitcher) *
Interweekly Stagnation
(4 Per Pitcher) **
Mean ± SD
(min–max)
MPN/100 mL
Mean ± SD
(min–max)
MPN/100 mL
14.4 × 103 ± 4.4 × 1035.9 × 103 ± 3.5 × 103
(6.4–1.6 × 104)(0.0–9.1 × 103)
25.3 × 105 ± 7.0 × 1052.1 × 106 ± 2.6 × 106
(0.0–2.2 × 106)(0.0–5.6 × 106)
32.6 × 101 ± 4.9 × 1011.8 ± 2.5
(0.0–2.0 × 102)(0.0–5.3)
45.5 × 101 ± 9.5 × 1015.0 × 102 ± 1.0 × 103
(0.0–3.3 × 102)(0.0–2.0 × 103)
53.2 × 101 ± 5.3 × 1014.2 ± 8.4
(0.0–1.4 × 102)(0.0–1.7 × 101)
65.6 × 101 ± 7.6 × 1018.4 ± 1.3 × 101
(0.0–2.0 × 102)(0.0–2.7 × 101)
78.9 ± 1.7 × 1010
0.0–5.3 × 101(0.0–0.0)
81.0 × 101 ± 2.6 × 1010
0.0–1.0 × 102(0.0–0.0)
96.7 ± 1.2 × 1010
0.0–3.2 × 101(0.0–0.0)
* interdaily breaks are 16/pitcher and analyses were performed in triplicate (N = 48). ** interweekly breaks are 4/pitcher and analyses were performed in triplicate (N = 12). SD: standard deviation.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Briancesco, R.; Paduano, S.; Semproni, M.; Vitanza, L.; Bonadonna, L. Behavior of Pseudomonas aeruginosa and Enterobacter aerogenes in Water from Filter Jugs. Int. J. Environ. Res. Public Health 2020, 17, 8263. https://0-doi-org.brum.beds.ac.uk/10.3390/ijerph17218263

AMA Style

Briancesco R, Paduano S, Semproni M, Vitanza L, Bonadonna L. Behavior of Pseudomonas aeruginosa and Enterobacter aerogenes in Water from Filter Jugs. International Journal of Environmental Research and Public Health. 2020; 17(21):8263. https://0-doi-org.brum.beds.ac.uk/10.3390/ijerph17218263

Chicago/Turabian Style

Briancesco, Rossella, Stefania Paduano, Maurizio Semproni, Luca Vitanza, and Lucia Bonadonna. 2020. "Behavior of Pseudomonas aeruginosa and Enterobacter aerogenes in Water from Filter Jugs" International Journal of Environmental Research and Public Health 17, no. 21: 8263. https://0-doi-org.brum.beds.ac.uk/10.3390/ijerph17218263

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop