Using Low-Cost Sensors to Assess Fine Particulate Matter Infiltration (PM2.5) during a Wildfire Smoke Episode at a Large Inpatient Healthcare Facility

1
Environmental Health Services, BC Center for Disease Control, Vancouver, BC V5Z 4R4, Canada
2
Department of Mechanical Engineering, The University of British Columbia, Vancouver, BC V6T 1Z4, Canada
3
Air Health Sciences Division, Health Canada, Ottawa, ON K1A 0K9, Canada
4
Provincial Health Services Authority, Vancouver, BC V6H 4C1, Canada
5
Vancouver Coastal Health, Vancouver, BC V5Z 1A1, Canada
6
School of Population and Public Health, The University of British Columbia, Vancouver, BC V6T 1Z3, Canada
*
Author to whom correspondence should be addressed.
Academic Editors: Tom Cole-Hunter and Mark J. Nieuwenhuijsen
Int. J. Environ. Res. Public Health 2021, 18(18), 9811; https://0-doi-org.brum.beds.ac.uk/10.3390/ijerph18189811
Received: 5 August 2021 / Revised: 13 September 2021 / Accepted: 16 September 2021 / Published: 17 September 2021
(This article belongs to the Special Issue Low-Cost Sensors for Environmental Research and Public Health)
Wildfire smoke exposure is associated with a range of acute health outcomes, which can be more severe in individuals with underlying health conditions. Currently, there is limited information on the susceptibility of healthcare facilities to smoke infiltration. As part of a larger study to address this gap, a rehabilitation facility in Vancouver, Canada was outfitted with one outdoor and seven indoor low-cost fine particulate matter (PM2.5) sensors in Air Quality Eggs (EGG) during the summer of 2020. Raw measurements were calibrated using temperature, relative humidity, and dew point derived from the EGG data. The infiltration coefficient was quantified using a distributed lag model. Indoor concentrations during the smoke episode were elevated throughout the building, though non-uniformly. After censoring indoor-only peaks, the average infiltration coefficient (range) during typical days was 0.32 (0.22–0.39), compared with 0.37 (0.31–0.47) during the smoke episode, a 19% increase on average. Indoor PM2.5 concentrations quickly reflected outdoor conditions during and after the smoke episode. It is unclear whether these results will be generalizable to other years due to COVID-related changes to building operations, but some of the safety protocols may offer valuable lessons for future wildfire seasons. For example, points of building entry and exit were reduced from eight to two during the pandemic, which likely helped to protect the building from wildfire smoke infiltration. Overall, these results demonstrate the utility of indoor low-cost sensors in understanding the impacts of extreme smoke events on facilities where highly susceptible individuals are present. Furthermore, they highlight the need to employ interventions that enhance indoor air quality in such facilities during smoke events. View Full-Text
Keywords: indoor air quality; PM2.5; wildfire smoke; infiltration; low-cost sensors; healthcare facility indoor air quality; PM2.5; wildfire smoke; infiltration; low-cost sensors; healthcare facility
Show Figures

Graphical abstract

MDPI and ACS Style

Nguyen, P.D.M.; Martinussen, N.; Mallach, G.; Ebrahimi, G.; Jones, K.; Zimmerman, N.; Henderson, S.B. Using Low-Cost Sensors to Assess Fine Particulate Matter Infiltration (PM2.5) during a Wildfire Smoke Episode at a Large Inpatient Healthcare Facility. Int. J. Environ. Res. Public Health 2021, 18, 9811. https://0-doi-org.brum.beds.ac.uk/10.3390/ijerph18189811

AMA Style

Nguyen PDM, Martinussen N, Mallach G, Ebrahimi G, Jones K, Zimmerman N, Henderson SB. Using Low-Cost Sensors to Assess Fine Particulate Matter Infiltration (PM2.5) during a Wildfire Smoke Episode at a Large Inpatient Healthcare Facility. International Journal of Environmental Research and Public Health. 2021; 18(18):9811. https://0-doi-org.brum.beds.ac.uk/10.3390/ijerph18189811

Chicago/Turabian Style

Nguyen, Phuong D.M., Nika Martinussen, Gary Mallach, Ghazal Ebrahimi, Kori Jones, Naomi Zimmerman, and Sarah B. Henderson 2021. "Using Low-Cost Sensors to Assess Fine Particulate Matter Infiltration (PM2.5) during a Wildfire Smoke Episode at a Large Inpatient Healthcare Facility" International Journal of Environmental Research and Public Health 18, no. 18: 9811. https://0-doi-org.brum.beds.ac.uk/10.3390/ijerph18189811

Find Other Styles
Note that from the first issue of 2016, MDPI journals use article numbers instead of page numbers. See further details here.