On the Efficacy of PCM to Shave Peak Temperature of Crystalline Photovoltaic Panels: An FDM Model and Field Validation

Department of Energy, Information Engineering and Mathematical Models, DEIM, Viale delle Scienze, Ed.9, Palermo 90128, Italy
*
Author to whom correspondence should be addressed.
Energies 2013, 6(12), 6188-6210; https://0-doi-org.brum.beds.ac.uk/10.3390/en6126188
Submission received: 12 July 2013 / Revised: 11 November 2013 / Accepted: 14 November 2013 / Published: 28 November 2013

Abstract

:
The exploitation of renewable energy sources and specifically photovoltaic (PV) devices have been showing significant growth; however, for a more effective development of this technology it is essential to have higher energy conversion performances. PV producers often declare a higher efficiency respect to real conditions and this deviation is mainly due to the difference between nominal and real temperature conditions of the PV. In order to improve the solar cell energy conversion efficiency many authors have proposed a methodology to keep the temperature of a PV system lower: a modified crystalline PV system built with a normal PV panel coupled with a Phase Change Material (PCM) heat storage device. In this paper a thermal model analysis of the crystalline PV-PCM system based on a theoretical study using finite difference approach is described. The authors developed an algorithm based on an explicit finite difference formulation of energy balance of the crystalline PV-PCM system. Two sets of recursive equations were developed for two types of spatial domains: a boundary domain and an internal domain. The reliability of the developed model is tested by a comparison with data coming from a test facility. The results of numerical simulations are in good agreement with experimental data.

1. Introduction

The intense exploitation of fossil fuels has caused an increase in the concentration of carbon dioxide from 280 to 370 ppm and a consequent estimated global warming from 0.4 to 0.8 °C [1]. The global effort to fight the effects of global climate change has been oriented to reduce energy consumptions through new technologies [2] and to ensure a more efficient exploitation of Renewable Energy Sources (RES) [3].
Among RES, solar energy is the most important and available natural resource. During the last decade there was a widespread use of photovoltaic (PV) systems not only for decentralized production in advanced countries but also in developing countries, where the most likely alternative to produce electricity is related to the use of poor fuels (coal and lignite, peat, etc. which are very polluting) and biomass [4].
A key element of a wider dissemination of PV systems is represented by high power conversion efficiency. Concerning this point, the energy produced by a PV cell depends, apart from materials, on other two important parameters: the amount of the incident radiation and the temperature of the PV cell.
The performances of a PV panel in fact are defined by manufacturers according to the “peak power”, which identifies the maximum electric power supplied by the PV panel when it receives an insolation of 1 kW/m2 with air mass 1.5 and the cell temperature is maintained at 25 °C (Standard Test Conditions). These parameters are only observed under reference conditions, because solar radiation has a variable intensity and the panel is subjected to significant temperature variations, with temperature values much higher than 25 °C. In real conditions performances of a PV panel are different from those declared under the nominal conditions and the conversion efficiency decreases when the temperature of the cell increases [5].
The wind speed greatly influences heat exchange between the PV panel and the external environment, mitigating its temperature; however, the wind is often too weak, especially in densely populated urban areas [6,7,8], to provide the desirable cooling of the solar cell. Obviously, there are other parameters that can affect PV panel cooling [9,10]. Furthermore, releasing heat to the air in summertime will cause side effects like intensified heat islands in case of large numbers of installations.
Among other measures aimed to increase the energy conversion, Phase Change Materials (PCMs) have been receiving increased attention, due to their capacity to store large amounts of thermal energy in narrow temperature range. A PCM is a substance with a high heat of fusion which, by melting and solidifying at a certain temperature, is capable of storing and releasing large amounts of energy. Heat is absorbed or released when the material changes from solid to liquid and vice versa. PCMs represent a possible solution that may reduce peak loads and thermal energy consumption in buildings due to their good insulation properties and thermal inertia effects related to the phase change phenomenon [11,12,13]. Despite the higher conductivity, compared to usual insulation materials used in buildings, PCM have been proved efficient in reducing peak heat fluxes by as much as 38% [14]. Indeed this property makes them ideal for passive heat storage in different building applications such as in the envelope of the building, in radiant floor heating systems, in free cooling systems, in photovoltaic elements and in building integrated PV [15,16,17,18,19,20,21,22,23,24,25,26].
The idea to couple the PCMs with the photovoltaic technology arises from the features of these materials to absorb large amounts of heat (keeping the temperature almost constant) when the heat is not required and overheating would cause a drop in the efficiency of photovoltaic cells. The absorbed heat should be then released to the surrounding air during night when the panel does not produce electrical power. The application of PCM coupled to a PV panel may represent an innovative technological solution to smooth daily temperature fluctuations and improve energy efficiency of the panel, however, PCMs are generally characterized by low thermal conductivity.
The capability of PCM to ensure a thermal regulation for a PV system can be better understood by analyzing heat transfer process across a multi-layered system in which one of the layers is composed by a material that changes phase during the day.
The aim pursued by the authors in this paper was to investigate a method to increase the energy performance of a photovoltaic panel by decreasing the operating temperature by means of PCM. This application has recently been suggested by other authors that have carried out some numerical studies. In this paper, a finite difference model capable of forecasting the variable temperature profile of a crystalline PV-PCM system is described; the adopted numerical scheme is presented in detail, also discussing the equations of the model and the resolution system using the FDM approach (finite difference method). In order to validate the numerical model, we performed a comparison with data derived by a real-time monitoring apparatus.

2. General Description of the PV-PCM Configuration

Considering a PV panel coupled with PCM system, the energy balance must take into account the presence of the phase-change material. Schematically, the energy exchanges in a crystalline PV-PCM system can be exemplified as shown in Figure 1.
Figure 1. PV-PCM cross-section (thicknesses not presented at real scale, for clarity of representation).
Figure 1. PV-PCM cross-section (thicknesses not presented at real scale, for clarity of representation).
Energies 06 06188 g001
Due to the presence of a simple geometry, it was possible to adopt a one-dimensional approach, considering only a heat flow orthogonal to the PV plane. The simplification of the thermal problem, compared to a more accurate representation in 2D or 3D [27], does not lead to unacceptable errors in the evaluation of the temperature field. The hypothesis of heat flow mono-dimensionality is in fact justified by ratio thickness/surface which is close to 0.02 m−1 in case of a crystalline PV-PCM system. The thermo-physical characteristics of each component are also constant in the other two directions and neglecting the effects relative to the edges of the panel, the overall energy balance remains practically unchanged. Furthermore the PCM is confined in small vacuum plastic bags of about 250 mL in volume. This configuration, because of high viscosity of the material in liquid phase, allows us to completely exclude the establishment of natural or buoyant convection. In Figure 1, hrad and hconv respectively represent the external radiative and convective coefficients.
Let us refer to a particular geometry, assuming the system composed by:
  • A tempered glass sheet with a thickness of 3.2 mm (glass layer);
  • 1 mm of PET plastic panel on which are “printed” the silicon cells; the silicon cells are considered having negligible thickness (plastic layer);
  • An optional layer of air interposed between the panel and the heat storage system representing a possible imperfect contact (air layer);
  • A plastic layer that takes into account the bag that contains the PCM (bag layer);
  • About 5 cm of PCM (PCM layer).
Figure 1 represents the section of the geometry along the thickness of the crystalline PV-PCM system where it is possible to identify all the layers involved: the glass panel, the PET panel, the layer of air due to the imperfect contact of the envelope of PCM with the PV, the thickness of the envelope containing the PCM and the PCM layer itself.
The crystalline PV-PCM system is presented as a multi-layer plate exposed to solar radiation and exchanging heat with the external environment by convection and radiation. Depending on the properties of the PCM and on the amount of energy captured from the panel, the PCM layer can partially or totally melt during the maximum insolation, rejecting the same amount of energy initially stored (and possibly solidifying again) during the night. The first hypothesis considers the phase change perfectly isothermal. This hypothesis is not very far from reality because many PCMs are characterized by isothermal phase changes, while some paraffin and eutectic mixtures have a very short range of temperature during transition. However, the assumption of isothermal phase change represents a simplification of the real phenomenon where there are three phases: solid, mushy, and fluid [28,29]. In the following model proposed by the authors, an approach that takes into account the liquid fraction is adopted, neglecting the mushy phase. In case of non-isothermal transition, if the cp value is known at any temperature; the problem is reduced to a heat conduction case.

2.1. Energy Balance of PV System

In order to evaluate the energy production of the PV panel and the resulting radiative and convective exchanges with surrounding environment, the improved five parameters model of Lo Brano et al. has been used [28,29,30].
As concerns the thermal exchanges with surrounding environment (Figure 2), the following assumptions were made:
The net radiative power is:
Energies 06 06188 i001
where, εglass and εPET are respectively the emissivity of the glass and PET external surfaces; σ is the Boltzmann constant; Tsky is the fictive sky temperature calculated with the correlation of Swinbank [31]; TPET is temperature of the PET external surface of the PV panel [K]; Troof is the temperature of the external surface of the roof. In the proposed algorithm, the value of Troof is equal to the external air temperature Tair.
The heat rate “generated” (or, more appropriately, absorbed by incident radiation and not converted into electricity) in the silicon layer is:
Energies 06 06188 i002
where G is the solar radiation (W/m2); V is the voltage generated by the panel; R is a pure resistive electrical load; and τα is the product of transmission coefficient of glazing and absorption coefficient of silicon.
Figure 2. Sketch of energy exchanges of PV panel with surrounding environment.
Figure 2. Sketch of energy exchanges of PV panel with surrounding environment.
Energies 06 06188 g002

3. 1-D Thermal Model Based on Explicit Finite Difference Method

If we consider a one-dimensional approach with constant thermo-physical properties and without internal heat generation, assuming that the heat transfer is only due to conduction, the problem can be described by a system of equations involving two heat diffusion equations and an energy balance related to the PCM [25,26,27,32,33,34,35,36]:
Energies 06 06188 i003
where α and λ are the thermal diffusivity and the thermal conductivity respectively; the superscripts s and l refer to the solid and liquid phase; l is the specific solidification latent heat; and x = X(t) is the time function that identifies the position of the phase change boundary [37].
The balance relating to the system of Equations (3) refers to the energy balance of a homogeneous, continuous, isotropic system in one-dimensional geometry; the application of the finite difference method requires the discretization of the system both in space and time. However, in case of phase change of the medium, it is easier to use equations that are function of enthalpy variation, thus allowing us to reduce the above system to a single equation. The following model adopts the enthalpy approach, although other methods may be used, in order to allow for a simpler implementation into an algorithm.
If we assume that Tm is the temperature of the phase change and the liquid fraction is defined as:
Energies 06 06188 i004
The total enthalpy I can be expressed as sum of the sensible component S and the latent component Lf:
I = S + L · f
Then, rearranging the previous expressions:
Energies 06 06188 i005
dS = CdT
where C is the average heat capacity of an uncompressible substance (for small temperature variations the specific heat capacity can be assumed as constant).
In this case the previous system equation can be merged in a unique expression:
Energies 06 06188 i006
In the following paragraphs the enthalpy balance is separately written for superficial and internal nodes for different initial conditions, in order to explain the dependence of phase change from the position of node.
Equation (8) allows one to assess the enthalpy balance of the domain that pertains superficial and internal nodes. The finite difference approximation of the total enthalpy can be written as:
Energies 06 06188 i007
where the subscript n identifies the position of the examined nodal point and the superscript p denotes the time dependence; p + 1 denotes the present time while p denotes the previous time interval. To ensure the convergence of Equation (9) the condition should be fulfilled [38]:
Energies 06 06188 i008

3.1. Application of Enthalpy Balance

The thickness of the control volume associated with a generic border node 0 is halved respect to the thickness of a generic internal node; hence, using the enthalpy notation of Equation (8) and assuming that on the external surface there is a generic heat flux q (that takes into account the radiative exchange with surrounding environment) and a convective heat transfer process, we can state that:
Energies 06 06188 i009
where:
Energies 06 06188 i010
and then:
Energies 06 06188 i011
where A is the surface of the control volume (m2); ρ0 is the density of the control volume pertaining the superficial node 0 (kg·m−3); c0 is the specific heat at constant pressure pertaining the superficial node 0 (J·kg−1·K−1); Δx/2 is the thickness of the superficial domain 0 (m); Energies 06 06188 i012 is a function of thermal conductivities pertaining the superficial node 0 and the internal node 1 (W·m−1·K−1); Energies 06 06188 i013 is the temperature of the superficial node at the present time (K); Energies 06 06188 i014 is the temperature of the superficial node at the past time or previous time step (K); h is the convective heat transfer coefficient (W·m−2·K−1) calculated with the correlation of Furushima [39]; Energies 06 06188 i015 is the air temperature at the past time (K); Energies 06 06188 i016 is the temperature of the first internal node (after the superficial one) at the past time (K); qp is the external heat flux at the past time (W·m−2); l is the specific latent heat (J·kg−1). A similar total enthalpy balance may be also written for a generic internal node, assuming the presence of a generic conductive heat flow coming from the previous and the next node.
Furthermore, the enthalpy/energy balance is written considering also the presence of the energy flow due to the absorption of solar irradiance by the silicon layer. Given the thinness of this layer, (about 0.3 mm) and the high thermal conductivity of this material, the silicon layer is considered as a virtual surface that separates the glass layer and the support material of the cells (plastic). For this purpose, the discretisation of the system is operated so that this separation surface (silicon) does not coincide with the position of any node; otherwise would be impossible to describe any extensive property pertaining this node and its domain. The energy deposition due to the absorption of solar irradiance is taken into account by considering two conductive heat flows: one that goes to the glass layer and the other that goes to the plastic layer. The paths among the point of origin of this energy deposition (the virtual surface of silicon), the glass (node n) and the plastic (node n + 1) layers are then equal to half of the distance between two nodes. For this reason, only in this case, the arrows do not extend between two nodes but originate from the separation surface (silicon).
Denoting by qn+1→n the flow that is originated in the separation border between the nodes n + 1 and n (Figure 3), we can write the total enthalpy balance in explicit discretized form; this method allows to calculate the state of a system at the successive time step “t + 1”, once calculated the state of the system at the current time “t”.
Figure 3. Scheme of spatial discretization of PV-PCM system.
Figure 3. Scheme of spatial discretization of PV-PCM system.
Energies 06 06188 g003
Starting from the approach followed by [40], where a simple implicit computational model for isothermal phase change was presented, the authors developed a modified algorithm based on an explicit finite difference formulation of the heat equation. The explicit approach followed by the Authors has been proved numerically stable and convergent if the Fourier number is less than 0.5 (which is our case). In contrast with the method by Zivkovic et al. [40], our approach is generally less numerically intensive compared with the implicit method. A forward difference at time t and a first-order central difference for the space derivative at position x was used. In order to use the method for the PV-panel system, two sets of recursive equations have been developed for two types of spatial domains: a boundary domain characterized by a length equal to Δx/2 with a representative node placed on the surface, and an internal domain with length equal to Δx with a representative node placed in the middle. The novelty concerning the definition of a boundary domain allows us to directly consider the radiative and convective heat transfer occurring on the surface in the recursive equation. Furthermore, the presence of a generic local heat flux q is always considered to properly simulate the eventual presence of an active surface.
In the crystalline PV-PCM model such a heat flux will be not null only at one border between two consecutive nodes, where is located the surface of silicon; the flux q will be obviously null elsewhere. In the hypothesis of only conductive heat flux coming from the previous and next nodes, it is possible to write that for the n-th domain:
I n p + 1 I n p Δ t = ρ n c n A Δ x Δ t ( T n p + 1 T n p ) + l ρ n A Δ x Δ t ( f n p + 1 f n p ) = λ ¯ n 1 n A Δ x ( T n 1 p T n p ) + λ ¯ n n + 1 A Δ x ( T n + 1 p T n p ) + q n 1 n λ n λ n 1 + λ n A + q n n + 1 λ n λ n + λ n + 1 A
and then:
ρ n c n ( T n p + 1 T n p ) + l ρ n ( f n p + 1 f n p ) = λ ¯ n 1 n Δ t Δ x 2 ( T n 1 p T n p ) + λ ¯ n + 1 n Δ t Δ x 2 ( T n + 1 p T n p ) + q n 1 n λ n Δ t Δ x ( λ n 1 + λ n ) + q n n + 1 λ n Δ t Δ x ( λ n + λ n + 1 )
As already written above, the proposed model takes into account the liquid fraction neglecting the mushy phase. For the resolution of Equations (13) and (15), representing the enthalpy balance for control volumes associated with superficial and internal nodes at the time p + 1, respectively, we should distinguish four different cases:
  • Case I: No phase change;
  • Case II: phase change;
  • Case III: Just started phase change;
  • Case IV: Just ending phase change.

3.1.1. Case I: Fully Solid or Fully Liquid (No Phase Change)

Energies 06 06188 i017
In this case there is not any phase change and the time variation of the liquid fraction is null. The Equations (13) and (15) can be solved by iterative method in terms of temperature:
For the superficial node:
Energies 06 06188 i018
For internal nodes:
Energies 06 06188 i019

3.1.2. Case II: Phase Change

Energies 06 06188 i020
When the phase change is occurring, it is possible to make some observations. First of all, if the phase change is isothermal, during this process the temperature is locked to the value Tm as long as the liquid fraction is between 0 and 1. Obviously, during the process the variation of sensible enthalpy is null. When the phase change is starting the superficial temperature is Tm, and the unknown value is represented by the liquid fraction. In this case it is possible to state:
Energies 06 06188 i021
In this condition the liquid fraction is:
  • For the superficial node:
    Energies 06 06188 i022
  • For the internal nodes:
    Energies 06 06188 i023

3.1.3. Case III: Just started Phase Change

Energies 06 06188 i024
Energies 06 06188 i025
Energies 06 06188 i026
An additional term has to be evaluated to consider the sensible heat that the control volume has adsorbed/released to pass from the initial temperature Energies 06 06188 i027 to the phase change temperature Energies 06 06188 i028 during the examined time step. The value of c to be considered depends on the type of transition. If the medium is melting the value of c is the specific heat of liquid phase. In case of solidification, the value of c is the specific heat of solid phase.
3.
For the superficial node:
Energies 06 06188 i029
4.
For the internal nodes:
Energies 06 06188 i030

3.1.4. Case IV: Just Ending Phase Change

Energies 06 06188 i031
Energies 06 06188 i032
Energies 06 06188 i033
An additional term has to be evaluated to consider the sensible heat that the control volume has adsorbed/released to pass from the initial temperature Energies 06 06188 i027 to the phase change temperature Energies 06 06188 i028 during the examined time step.
  • For the superficial node:
    Energies 06 06188 i034
  • For the internal nodes:
    Energies 06 06188 i035
When the phase change is just ending, the superficial temperature is again free to float; the last subtractive term in Equation (31) and (32) accounts for the necessary latent heat to end the phase changing.
Concerning the numerical method, the explicit approach followed by the authors can occasionally result in stability problems. In these cases, the response is affected by fluctuations that disrupt and eventually make the solution completely unreliable. There are several criteria that ensure the stability of the method, and in our case, in the definition of the time step and for the size of the domain, we considered the following condition: Energies 06 06188 i036.

4. Deployment of the Algorithm

The previous equations described above allow us to develop an algorithm for the automatic calculation using software. In order to simplify the description of the calculation procedure, the iterative equations used and solved for each time step Δt have been rewritten in the following general form: for the superficial node:
Energies 06 06188 i037
For a stable and convergent solution in the algorithm the next steps are executed:
1. The coefficients A, B, C, D are calculated for each node taking into account the value of thermo-physical properties of the medium calculated at the previous time step:
Energies 06 06188 i038
2. All nodal temperatures are calculated with an iterative approach; eventually, the values of thermo-physical properties are updated to make them coherent with the calculated thermal field. In our practical application we used only values referring with the liquid or solid phase (even because the range of temperature is enough narrow). Nevertheless, if the tabular values of each property are known, our algorithm can use them.
3. Only for PCM nodes, the phase of each domain are evaluated; possible conditions are: fully solid, fully liquid, starting of melting, phase changing, end of melting, starting of solidification, end of solidification.
4. Once calculated the conditions, a check is performed over temperatures, verifying that the correct equations were used. If one or more checks failed, the correct equations are used and all nodal temperatures are recalculated (back to step 2).
5. When phase change is starting, ending or occurring Energies 06 06188 i028, therefore the condition is:
Energies 06 06188 i039
6. Once all nodal temperatures are calculated with right equations, liquid fraction for under transition PCM domains are calculated.
Figure 4 and Figure 5 show the condition evaluation and liquid fraction calculation flow charts for rising temperature case:
Figure 4. Flow diagram of (a) temperature calculation and (b) liquid fraction calculation (rising temperature).
Figure 4. Flow diagram of (a) temperature calculation and (b) liquid fraction calculation (rising temperature).
Energies 06 06188 g004
Figure 5. Flow diagram of (a) temperature calculation and (b) liquid fraction calculation (decreasing temperature).
Figure 5. Flow diagram of (a) temperature calculation and (b) liquid fraction calculation (decreasing temperature).
Energies 06 06188 g005
The algorithm presented was deployed in a software that uses a common programming language like VB.NET.

5. Description of Experimental Setup

In order to perform the comparison between measured and calculated data, an experimental system (Figure 6) was built up and situated on the top of the Energy Department of University of Palermo, (38°07' N, 13°22' E). The test facility consists of a silicon PV panel, a precision resistance set, a first class (ISO 9060) Delta Ohm pyrometer mod. LP PYRA 02 AV (DeltaOhm, Padova, Italy) linked to an Advantech ADAM 6024 (Advantech America, Mipitas, CA, USA) data acquisition module. A Davis Vantage PRO2 Plus Weather station (Davis Instruments Corp., Hayward, CA, USA) was used to collect the measurements of air temperature, relative humidity, wind speed and direction, horizontal global solar irradiance and atmospheric pressure.
Figure 6. Experimental set-up.
Figure 6. Experimental set-up.
Energies 06 06188 g006
A Kyocera KC175GHT-2 PV panel (Kyocera Solar Inc., Scottsdale, AZ, USA) was coupled with a PCM layer in the bottom part using a perforated metal mesh, bolted into the frame of the panel. A galvanized hexagonal iron wire mesh with a distance of mesh holes of 54 mm and a wire thickness equal to 0.9 mm was used. The PCM was encapsulated by a double package of plastic bag (Figure 7); the thickness of the two envelopes is equal to 0.4 mm.
Figure 7. The encapsulated PCM and its installation
Figure 7. The encapsulated PCM and its installation
Energies 06 06188 g007
Concerning the heat exchange mechanism, the PCM on the upper side is in contact with the back of the photovoltaic panel; on the lower side the PCM radiatively and convectively exchanges with the external environment. The solar radiation that affects the photovoltaic panel, producing power energy and at the same time heating the panel, constitutes the flow of incoming energy into the system. No other forced heat exchange mechanism is present in the system.
The silicon temperature was measured using thermocouples (type T, copper-constantan [2]) installed into little holes (red circles in Figure 8) made in the PET rear film of the panel. All data were collected every 30 min and stored for further calculations and ex-post processing.
Figure 8. Little holes in the PET film of the PV panel to measure the temperature.
Figure 8. Little holes in the PET film of the PV panel to measure the temperature.
Energies 06 06188 g008
In order to measure the electrical power produced by the PV panel, the electrical circuit has been closed to precision resistances Vishay RH250, (Vishay Intertechnology Inc., Malvern, PA, USA) with a tolerance of ±1% and a temperature coefficient of ±50 ppm/°C. Since the resistances never exceeded a temperature of 150 °C, their nominal values were considered known within the precision of ±1.625% [28,29,30].

6. Analysis of Results

The crystalline PV-PCM system above described was monitored during the summer season, when the system is subjected to the higher solar irradiance values, because we want verify the reliability of the proposed calculation algorithm. Several numerical simulations were performed on different days and the results were compared with measured data in terms of silicon layer temperature.
As concerns the PCM, Rubitherm RT-27 packages (Rubitherm Technologies GmbH, Berlin, Germany) were used, whose chemical composition was alkane hydrocarbons with the general formula CnH2n+2. The melting points of pure paraffins depend on the number of carbon atoms, this number is between 14 and 40 and melting temperature range is between 6 and 80 °C. In the experimental application that was tested by the authors, the paraffin used was characterised by a relatively low phase transition starting temperature (26 °C), that could be interesting for the typical Sicilian summer and autumn thermal regimes. The thermo-physically characteristics of the adopted PCM are listed in Table 1.
Table 1. Thermo-physical characteristics of the PCM.
Table 1. Thermo-physical characteristics of the PCM.
CharacteristicValueUnits
Transition phase26–28°C
Solid density0.87kg/L
Liquid density0.75kg/L
Heat Storage Capacity179kJ/kg
Specific enthalpy of phase change1.8–2.4J/kg
Thermal Conductivity0.2W/mK
Figure 9 and Figure 10 represent the climatic conditions registered in two typical short periods of the summer season in Palermo, relating respectively with a couple of partially cloudy days and with a set of three consecutive sunny days.
Figure 9. Trends of climatic parameters in Palermo, 26–27 June 2010.
Figure 9. Trends of climatic parameters in Palermo, 26–27 June 2010.
Energies 06 06188 g009
Figure 10. Trends of weather parameters in Palermo, 30 June–2 July 2010.
Figure 10. Trends of weather parameters in Palermo, 30 June–2 July 2010.
Energies 06 06188 g010
Figure 11, Figure 12, Figure 13 and Figure 14 show the comparison between the measured temperatures and those calculated by the proposed algorithm. In detail Figure 11 and Figure 13 represent the comparison of the measured and calculated temperatures of the PV system without PCM layer, the other Figure 12 and Figure 14 show the comparison of the trend temperatures of the PV-PCM system. In both cases, the proposed algorithm good represent the operative conditions of the system.
The high temperatures measured for the PV cell and shown in Figure 12 and Figure 14 testify to a poor performance of the paraffin as a heat storage medium. Due to the low capability of the PCM to discharge the surplus heat during the night, (as consequence of its low thermal diffusivity) the paraffin is revealed to be efficient in cooling the panel only for few days after the installation; this result, although controversial in literature [13,41,42] has been verified experimentally in previous works.
Figure 11. Temperature trend of the measured and simulated PV system together with measured power output, in Palermo, 26–27 June 2010.
Figure 11. Temperature trend of the measured and simulated PV system together with measured power output, in Palermo, 26–27 June 2010.
Energies 06 06188 g011
Figure 12. Temperature trend of the measured and simulated PV-PCM system together with measured power output, in Palermo, 26–27 June 2010.
Figure 12. Temperature trend of the measured and simulated PV-PCM system together with measured power output, in Palermo, 26–27 June 2010.
Energies 06 06188 g012
Figure 13. Temperature trend of the measured and simulated PV system, together with measured power output, in Palermo, 30 June–2 July 2010.
Figure 13. Temperature trend of the measured and simulated PV system, together with measured power output, in Palermo, 30 June–2 July 2010.
Energies 06 06188 g013
Figure 14. Temperature trend of the measured and simulated PV-PCM system together with measured power output, in Palermo, 30 June–2 July 2010.
Figure 14. Temperature trend of the measured and simulated PV-PCM system together with measured power output, in Palermo, 30 June–2 July 2010.
Energies 06 06188 g014
It may be observed that a flat power profile occurred during the hours with highest irradiance; this is due to the reaching of saturation conditions of the PV panel, where significant changes in solar irradiance do not induce variations in the power output. This particular operating condition was voluntarily selected for our study; in fact, under saturation conditions, the temperature of the PV panel experiences wider fluctuations being inhibited any further increase in power output delivery.
The finite differences calculation model of the PV panel coupled with a PCM thermal storage system has achieved excellent results both for sunny and partially cloudy days. The average percentage gap is calculated as [(TcalculatedTmeasured)/Tmeasured], while the absolute value is calculated as [│TcalculatedTmeasured│/Tmeasured].
Looking at the graphs represented before, it is possible to see as the calculated temperature trend’s is in good agreement with measured temperatures, validating the reliability of the calculation model.
The calculated temperatures at night are significantly lower than the comparable measured: this is an indication of an incorrect estimate irradiative heat exchange, which were estimated under the assumption of the sky always clear. Table 2 shows that the differences between the measured and calculated values are acceptable.
Table 2. Comparison between measured and calculated operative temperature of PV-PCM system.
Table 2. Comparison between measured and calculated operative temperature of PV-PCM system.
Gaps27–28 June30 June–2 July
Operative temperatureRelative Average gap4.85%4.90%
Absolute Relative Average gap8.37%4.92%
Maximum negative gap−6.43 °C−0.11 °C
Maximum positive gap7.55 °C6.01 °C

7. Conclusions

The heat exchange between the crystalline PV-PCM system and the surrounding environment is governed by several variables such as the thermo-physical properties of all the materials making up the system, the geometry, the weather conditions, the heat transfer coefficients (radiative and convective). The aim of this paper was to develop a simplified numerical model, relying upon the assumption of a one-dimensional geometry and was proposed for a PV system coupled with a PCM-based heat storage. The model is based on two sets of recursive equations that apply to two distinct types of spatial domains: internal domains with a length equal to Δx and a representative node located in the middle, and a boundary domain with halved length (Δx/2) and a representative node placed on the surface. The method assumes the phase change to be strictly isothermal and updates, at each time step, the liquid fraction of domains and the temperature of corresponding nodes. A comparison was performed between the numerical results achieved by the proposed algorithm and the experimental data obtained in-situ at a test facility. Despite the adoption of a simplified approach, relying upon the assumption of a one-dimensional geometry, the analysis revealed that the proposed thermal model is reliable under different climatic conditions; both in the cases of sunny and partially cloudy days; in fact, the relative average gap between calculated and measured silicon temperature remained below 5%.
Data monitored in our experimental setup have demonstrated that the dominant thermal process is that one related to the discharge of the surplus heat during the night. A better thermal contact would improve the heat transfer between the rear surface of the PV and the heat storage device. However, the main limit of this system is related to the heat transfer between the PCM heat storage and the surrounding environment. The cyclic transition of the PCM during the summer happens only one day and after the PCM remained in liquid phase. These observations thus frustrate the use of paraffin to shave the peak temperature of a photovoltaic panel and decisively disprove the results shown in other scientific works.
In order to improve the accuracy of the simulation, the authors are working on a more sophisticated calculation scheme using the Crank-Nicolson approach [43]. Although this method is more complex to implement in software, this approach should allow us to obtain a good simulation using less computation time. Finally, the presented method can be used even for other PCM configurations such as those one employed in civil structures to improve the thermal performance of buildings envelope. In addition, the model described in the paper can be effectively used in other contexts in which the PCM is uses to smooth the peak temperature due to solar radiation.

Nomenclature:

A
is the surface of the control volume (m2)
C
average heat capacity of an uncompressible substance (J/kg·K)
cp
specific heat coefficient(J/kg·K)
f
liquid fraction
G
solar irradiance (W/m2)
h
convective heat transfer coefficient (W/m2·K)
hconv
convective coefficients (W/m2·K)
hrad
radiative coefficients
I
total enthalpy (J/kg)
l
specific latent heat (J/kg)
L
latent heat component (J/kg)
n
position of the node (m)
P
net radiative power (W/m2)
q
generic heat flux (W/m2)
R
resistive electrical load (Ω)
S
sensible heat component (J/kg)
T
generic temperature; cell temperature of the PV panel (K)
Tair
external air temperature (K)
Tsky
sky temperature (K)
TPET
temperature of the PET external surface of the PV panel (K)
Troof
temperature of the external surface of the roof (K)
V
voltage generated by the PV panel (V)
x = X (t)
time function that identifies the position of the phase change boundary (m)
Δx/2
thickness of the superficial domain (m)
Δt
time step (s)
α
thermal diffusivity (m2/s)
εglass
emissivity of the glass layer of the PV panel
εPET
emissivity of the PET external surface of the PV panel
λ
thermal conductivity (W/m·K)
σ
Boltzmann constant 5.67 × 10−8 (W/m2·K4)
τα
product of transmission coefficient of glazing and absorption coefficient of silicon

Subscripts:

i
initial time step
l
liquid phase
m
melting phase
s
solid phase
p + 1
present time interval
p
the previous time interval
t
current time step
t + 1
successive time step
0
superficial node

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Schneider, K.; Erez, J. The effect of carbonate chemistry on calcification and photosynthesis in the hermatypic coral Acropora eurystoma. Limnol. Oceanogr. 2006, 51, 1284–1293. [Google Scholar] [CrossRef]
  2. Cardona, E.; Piacentino, A. A measurement methodology for monitoring a CHCP pilot plant for an office building. Energy Build. 2003, 35, 919–925. [Google Scholar] [CrossRef]
  3. Cellura, M.; Campanella, L.; Ciulla, G.; Guarino, F.; Lo-Brano, V.; Cesarini, D.N.; Orioli, A. The redesign of an Italian building to reach net zero energy performances: A case study of the SHC Task 40—ECBCS Annex 52. ASHRAE Trans. 2011, 117, 331–339. [Google Scholar]
  4. International Energy Agency. World Energy Outlook 2011; Paris OECD International Energy Agency: Paris, France, 2011. [Google Scholar]
  5. Ciulla, G.; Lo Brano, V.; Marvuglia, A.; Orioli, A. A Photovoltaic Panel Coupled with a Phase Changing Material Heat Storage System in Hot Climates. In Proceeding of the 25th International Conference on Passive and Low Energy Architecture: Towards Zero Energy Building, PLEA 2008, Dublin, Ireland, 22 October 2008.
  6. Lo Brano, V.; Orioli, A.; Ciulla, G.; Culotta, S. Quality of wind speed fitting distributions for the urban area of Palermo, Italy. Renew. Energy 2011, 36, 1026–1039. [Google Scholar]
  7. Lopes, A.; Saraiva, J.; Alcoforado, M.J. Urban boundary layer wind speed reduction in summer due to urban growth and environmental consequences in Lisbon. Environ. Model. Softw. 2011, 26, 241–243. [Google Scholar] [CrossRef]
  8. Memon, R.A.; Leung, D.Y.C.; Liu, C.H. Effects of building aspect ratio and wind speed on air temperatures in urban-like street canyons. Build. Environ. 2010, 45, 176–188. [Google Scholar] [CrossRef]
  9. Mirzaei, P.A.; Carmeliet, J. Influence of the underneath cavity on buoyant-forced cooling of the integrated photovoltaic panels in building roof: A thermography study. Prog. Photovolt. Res. Appl. 2013. [Google Scholar] [CrossRef]
  10. Corbin, C.D.; Zhai, Z.J. Experimental and numerical investigation on thermal and electrical performance of a building integrated photovoltaic thermal collector system. Energy Build. 2010, 42, 76–82. [Google Scholar] [CrossRef]
  11. Tyag, V.; Buddhi, D. PCM thermal storage in buildings: A state of art. Renew. Sustain. Energy Rev. 2007, 11, 1146–1166. [Google Scholar] [CrossRef]
  12. Halawa, E.; Bruno, F.; Saman, W. Numerical analysis of a PCM thermal storage system with varying wall temperature. Energy Convers. Manag. 2005, 46, 2592–2604. [Google Scholar] [CrossRef]
  13. Liu, H.; Awbi, H.B. Performance of phase change material boards under natural convection. Build. Environ. 2009, 44, 1788–1793. [Google Scholar] [CrossRef]
  14. Zhang, M.; Medina, M.A.; King, J.B. Development of a thermally enhanced frame wall with phase-change materials for on-peak air conditioning demand reduction and energy savings in residential buildings. Int. J. Energy Res. 2005, 29, 795–809. [Google Scholar] [CrossRef]
  15. Zhou, D.; Zhao, C.Y.; Tian, Y. Review on thermal energy storage with phase change materials (PCMs) in building applications. Appl. Energy 2012, 92, 593–605. [Google Scholar] [CrossRef] [Green Version]
  16. Izquierdo-Barrientos, M.A.; Belmonte, J.F.; Rodríguez-Sánchez, D.; Molina, A.E.; Almendros-Ibáñez, J.A. A numerical study of external building walls containing phase change materials (PCM). Appl. Therm. Eng. 2012, 47, 73–85. [Google Scholar] [CrossRef]
  17. Huang, M.J.; Eames, P.C.; Norton, B. Thermal regulation of building-integrated photovoltaic using phase change materials. Int. J. Heat Mass Transf. 2004, 47, 2715–2733. [Google Scholar] [CrossRef]
  18. Jeon, J.; Jeong, S.G.; Lee, J.H.; Seo, J.; Kim, S. High thermal performance composite PCMs loading xGnP for application to building using radiant floor heating system. Solar Energy Mater. Solar Cells 2012, 101, 51–56. [Google Scholar] [CrossRef]
  19. Chintakrinda, K.; Weinstein, R.D.; Fleischer, A.S. A direct comparison of three different material enhancement methods on the transient thermal response of paraffin phase change material exposed to high heat fluxes. Int. J. Therm. Sci. 2011, 50, 1639–1647. [Google Scholar] [CrossRef]
  20. Huang, M.J.; Eames, P.C.; Norton, B. Phase change materials for limiting temperature rise in building integrated photovoltaics. Solar Energy 2006, 80, 1121–1130. [Google Scholar] [CrossRef]
  21. Hasan, A.; McCormack, S.J.; Huang, M.J.; Norton, B. Evaluation of phase change materials for thermal regulation enhancement of building integrated photovoltaics. Solar Energy 2010, 84, 1601–1612. [Google Scholar] [CrossRef]
  22. Maiti, S.; Banerjee, S.; Vyas, K.; Patel, P.; Ghosh, P.K. Self-regulation of photovoltaic module temperature in V-trough using a metal-wax composite phase change matrix. Solar Energy 2011, 85, 1805–1816. [Google Scholar] [CrossRef]
  23. Weinlaeder, H.; Koerner, W.; Heidenfelder, M. Monitoring results of an interior sun protection system with integrated latent heat storage. Energy Build. 2011, 43, 2468–2475. [Google Scholar] [CrossRef]
  24. Ho, C.J.; Tanuwijava, A.O.; Lai, C.M. Thermal and electrical performance of a BIPV integrated with a microencapsulated phase change material layer. Energy Build. 2012, 50, 331–338. [Google Scholar] [CrossRef]
  25. Pascal, B.; Eclache, P.; Kuznik, F. Phase-change materials to improve solar panel’s performance. Energy Build. 2013, 62, 59–67. [Google Scholar] [CrossRef] [Green Version]
  26. Ciulla, G.; Lo Brano, V.; Messineo, A.; Peri, G. A numerical solution that determines the temperature field inside phase change materials: Application in buildings. J. Civ. Eng. Manag. 2013, 19, 518–528. [Google Scholar] [CrossRef]
  27. Huang, M.J.; Eames, P.C.; Norton, B. Comparison of a small-scale 3D PCM thermal control model with a validated 2D PCM thermal control model. Solar Energy Mater. Solar Cells 2006, 90, 1961–1972. [Google Scholar] [CrossRef]
  28. Lo Brano, V.; Orioli, A.; Ciulla, G. On the experimental validation of an improved five-parameter model for silicon photovoltaic modules. Solar Energy Mater. Solar Cells 2012, 105, 27–39. [Google Scholar] [CrossRef]
  29. Ciulla, G.; Lo Brano, V.; Moreci, E. Forecasting the cell temperature of PV modules with an adaptive system. Int. J. Photoenergy 2013. [Google Scholar] [CrossRef]
  30. Lo Brano, V.; Ciulla, G. An efficient analytical approach for obtaining a five parameters model of photovoltaic modules using only reference data. Appl. Energy 2013, 111, 894–903. [Google Scholar] [CrossRef]
  31. Swinbank, W.C. Long-wave radiation from clear skies. Q. J. R. Metereol. Soc. 1963, 89, 339–348. [Google Scholar] [CrossRef]
  32. Mirzaei, P.A.; Haghighat, F. Modeling of phase change materials for applications in whole building simulation. Renew. Sustain. Energy Rev. 2012, 16, 5355–5362. [Google Scholar] [CrossRef]
  33. Fan, L.W.; Khodadadi, J.M. Thermal conductivity enhancement of phase change materials for thermal energy storage: A review. Renew. Sustain. Energy Rev. 2011, 15, 24–46. [Google Scholar] [CrossRef]
  34. Voller, V.R.; Cross, M. Accurate solutions of moving boundary problems using enthalpy method. Int. J. Heat Mass Transf. 1981, 24, 545–556. [Google Scholar] [CrossRef]
  35. Voller, V.R. A heat balance integral method based on an enthalpy formulation. Int. J. Heat Mass Transf. 1987, 30, 604–607. [Google Scholar] [CrossRef]
  36. Voller, V.R. Fast implicit finite-difference method for the analysis of phase change problem. Numer. Heat Transf. 1990, 17, 155–169. [Google Scholar] [CrossRef]
  37. Lamberg, P.; Lehtiniemi, R.; Henell, A.M. Numerical and experimental investigation of melting and freezing processes in phase change material storage. Int. J. Therm. Sci. 2004, 43, 277–287. [Google Scholar] [CrossRef]
  38. Incropera, F.P.; de Witt, D.P. Fundamentals of Heat and Mass Transfer, 5th ed.; John Wiley & Sons: New York, NY, USA, 2002. [Google Scholar]
  39. Furushima, K.; Nawata, Y.; Sadatomi, M. Prediction of Photovoltaic (PV) Power Output Considering Weather Effects. In Proceedings of the ASME International Solar Energy Conference, Denver, CO, USA, 8–13 July 2006; pp. 7–13.
  40. Zivkovic, B.; Fujii, I. Analysis of isothermal phase change of phase change material within rectangular and cylindrical containers. Solar Energy 2001, 70, 51–61. [Google Scholar] [CrossRef]
  41. Ciulla, G. Un Modello di Simulazione del Comportamento Termico ed Elettrico di Pannelli Fotovoltaici Piani; Miglioramento Della Resa Energetica per mezzo di Materiali a Cambiamento di Fase (in Italian). Ph.D. Thesis, University of Palermo, Palermo, Italy, February 2009. [Google Scholar]
  42. Saitta, M. Materiali a Cambiamento di Fase Accoppiati a Moduli Fotovoltaici: Un’analisi Numerica (in Italian). Master’s Thesis, University of Palermo, Palermo, Italy, July 2010. [Google Scholar]
  43. Crank, J.; Nicolson, P. A Practical Method for Numerical Evaluation of Solutions of Partial Differential Equations of the Heat-Conduction Type. In Mathematical Proceedings of the Cambridge Philosophical Society; Cambridge University Press: Cambridge, UK, 1947; Volume 43, pp. 50–67. [Google Scholar]

Share and Cite

MDPI and ACS Style

Lo Brano, V.; Ciulla, G.; Piacentino, A.; Cardona, F. On the Efficacy of PCM to Shave Peak Temperature of Crystalline Photovoltaic Panels: An FDM Model and Field Validation. Energies 2013, 6, 6188-6210. https://0-doi-org.brum.beds.ac.uk/10.3390/en6126188

AMA Style

Lo Brano V, Ciulla G, Piacentino A, Cardona F. On the Efficacy of PCM to Shave Peak Temperature of Crystalline Photovoltaic Panels: An FDM Model and Field Validation. Energies. 2013; 6(12):6188-6210. https://0-doi-org.brum.beds.ac.uk/10.3390/en6126188

Chicago/Turabian Style

Lo Brano, Valerio, Giuseppina Ciulla, Antonio Piacentino, and Fabio Cardona. 2013. "On the Efficacy of PCM to Shave Peak Temperature of Crystalline Photovoltaic Panels: An FDM Model and Field Validation" Energies 6, no. 12: 6188-6210. https://0-doi-org.brum.beds.ac.uk/10.3390/en6126188

Article Metrics