Article

Material Viscoelasticity-Induced Drift of Micro-Accelerometers

1
School of Mechatronics Engineering, University of Electronic Technology and Science of China, Chengdu 611731, China
2
Institute of Electronic Engineering, China Academy of Engineering Physics, Mianyang 621900, China
*
Authors to whom correspondence should be addressed.
Submission received: 21 August 2017 / Revised: 7 September 2017 / Accepted: 12 September 2017 / Published: 14 September 2017

Abstract

:
Polymer-based materials are commonly used as an adhesion layer for bonding die chip and substrate in micro-system packaging. Their properties exhibit significant impact on the stability and reliability of micro-devices. The viscoelasticity, one of most important attributes of adhesive materials, is investigated for the first time in this paper to evaluate the long-term drift of micro-accelerometers. The accelerometer was modeled by a finite element (FE) method to emulate the structure deformation and stress development induced by change of adhesive property. Furthermore, the viscoelastic property of the adhesive was obtained by a series of stress–relaxation experiments using dynamic mechanical analysis (DMA). The DMA curve was imported into the FE model to predict the drift of micro-accelerometers over time and temperature. The prediction results verified by experiments showed that the accelerometer experienced output drift due to the development of packaging stress induced by both the thermal mismatch and viscoelastic behaviors of the adhesive. The accelerometers stored at room temperature displayed a continuous drift of zero offset and sensitivity because of the material viscoelasticity. Moreover, the drift level of accelerometers experiencing high temperature load was relatively higher than those of lower temperature in the same period.

1. Introduction

In packaging of microelectromechanical systems (MEMS), polymer-based materials, such as epoxy and silicone, are widely used for mounting the die chip on the substrate because of their numerous advantages compared with other joining methods [1,2]. However, this type of adhesive packaging, like other packaging themes, involves residual thermal stress/packaging stress due to the mismatch of coefficients of thermal expansion (CTE) of different structural materials [3]. The stress existing in structures and interfaces forms a stable equilibrium of micro-devices based on deformation compatibility conditions [4]. The formed equilibrium, however, is prone to be upset by the temperature load and/or the shift of material properties, such as elastic module and Poisson’s ratio. The temperature aspects are always related to the thermal effects’ influence on device performance, which has been studied intensively, while the material properties of the polymer-based materials in current studies are often neglected or simply assumed to be linear–elastic [5,6,7,8,9,10]. This assumption could give a relatively accurate evaluation of device performance in the low- and medium-precision application fields, but could not be used to predict the long-term stability or drift in areas requiring high precision, because the polymers actually exhibit viscoelasticity presenting elastic and viscous characteristics simultaneously [11,12], and they also possess the features of time and temperature dependence. The viscoelasticity-related issue has become one of the most critical steps for assessing the packaging quality and output performance of highly precise MEMS sensors [13,14]. Applying the viscoelastic property to model the MEMS devices could give a better agreement with the results observed in experiments than the previous elastic model [15]. The packaging stress in the MEMS was influenced not only by the temperature change, but also by its change rate due to the time-dependent property of polymer adhesives [16]. Besides, the viscoelastic behavior influenced by moisture was recognized as the cause of the long-term stability of micro-sensors in storage [17,18]. Current works on the viscoelastic effects mainly focus on the viscoelasticity-induced reliability issues of MEMS sensors, but the underlying mechanism of stress development over time and temperature is still open to further investigation.
This study aims to deeply investigate the effects of viscoelastic behavior of epoxy-based adhesive on the long-term stability of micro-capacitive accelerometers packaged in a ceramic shell by the adhesively bonding method. Section 2 gives an introduction to the working principle of micro-accelerometers, and theoretically determines the zero offset and sensitivity by the deformation of the sensitive structure of the accelerometer. In Section 3, the accurate viscoelastic property of the adhesive is obtained by a series of stress–relaxation tests by dynamic mechanical analysis (DMA), and the master curve is acquired by the proper shift function and fitted with the Prony function to implement finite element analysis (FEA). In Section 4, the obtained curve is introduced into the physical model of the accelerometer to study the deformation law of sensitive components subjected to four different time and temperature cycles, and then the zero offset and sensitivity of the accelerometer can be determined by the deformed structure. The simulation and experiments are also given in this section. The discussion and conclusion are provided in Section 5 and Section 6, respectively.

2. Structure and Principle

The simplified model of the capacitive accelerometers is shown in Figure 1. The sensitive component is a silicon-based structure supported elastically by four folded beams and bonded to a Pyrex glass substrate. The whole structure is packaged onto a ceramic shell with an epoxy-based adhesive through a curing process. When an acceleration, a, is applied in the sensitive direction, the movement of the proof mass induced by inertial force generates a gap change of sensing capacitors formed by a fixed finger on the silicon substrate and a movable finger on the proof mass [19,20]. The changed gap shifts the differential capacitance of capacitors, C1 and C2, and the output of the micro-accelerometer can be simply expressed as:
V o u t   =   G C 1     C 2 C 1   +   C 2 V b
where Vout is the output voltage of accelerometer, G is the amplification coefficient of the sensing circuit and Vb is the amptitude of carrier voltage.
Half of the sensitive component is selected to derive the analytical expressions of performance, zero offset and sensitivity of the micro-accelerometer. The folded beams anchored to separated sides are represented by two springs with different stiffness constants, k1 and k2, due to fabrication errors [21] (Figure 2). The output of the accelerometer, according to Equation (1), is directly proportional to the differential capacitance, which is dependent on the relative position between the fixed fingers and movable fingers. Therefore, the positions of finger anchors (3, 4) and the proof mass determine the performance parameters of the micro-accelerometer, and are influenced by the stress state of the whole structure. Ideally, the free state of packaged accelerometers should show no internal stress, but the packaging process with a fluctuating temperature leads to thermal stress in the chip due to different thermo–mechanical properties of the structural materials. Thus, the zero offset or bias of the micro-accelerometer can be expressed as [22]:
B i a s = K u m m
where K denotes the total stiffness of the folded beams, K = k1 + k2, m is the proof mass and um is the displacement of the proof mass center. Furthermore,
u m   =   k 1     k 2 k 1   +   k 2 ( P 1 x     l 1 Δ T α silicon )
where P1x denotes the longitudinal displacements of the point connecting the folded beams and the anchors; l1 is half the length of the proof mass; ∆T is the temperature change between curing temperature and room temperature; and αsilicon is the CTE of silicon.
The sensitivity of the micro-accelerometer can be expressed as:
S e n s i t i v i t y   =   ( 1 d 1     1 d 2 ) G m K
where d1 and d2 denote narrow and wide gaps once the curing process is completed, respectively. The sensitivity is mainly determined by the narrow gap, because d1 is much smaller than d2.
The Equations (3) and (4) represent the zero offset and sensitivity of the packaged micro-accelerometer, respectively. Both parameters are constant when the structure has no deformation or movement, because the silicon, glass, circuit and internal environment are almost invariant. The micro-accelerometer after storage, however, exhibited an obvious drift of performance parameters. That is to say, the structural equilibrium sustained by the residual thermal stress was upset by some factors related to the structural material properties.

3. Material Property

The sensor of the micro-accelerometer consists of four different materials including silicon, Pyrex glass, ceramic material and packaging adhesive. Silicon, Pyrex glass and the ceramic material were used broadly and have very stable material properties with linear elasticity. The Poisson ratio and CTE of the adhesive were assumed as constant values, because they have little impact on the packaging stress [23]. The material properties are listed in Table 1.
The packaging adhesive, a typical epoxy-based polymer, however, exhibits both elastic and viscous behaviors, that is, viscoelasticity. The elasticity responding to stress is instantaneous, while the viscous response is time-dependent and varies with temperature, which consequently has significant impact on the stress distribution in the micro-accelerometer. To measure the viscoelastic characteristics, therefore, is one of most critical steps before evaluating the stability of micro-accelerometers because of the time- and temperature-dependent feature of the adhesive. The common measuring method is through stress relaxation or creep tests [24]. Hence, a series of stress–relaxation tests were performed using dynamic mechanical analysis (TA instrument DMA Q800, New Castle, DE, USA). A rectangular specimen (35 mm × 10 mm × 2 mm) was prepared and cured by the same process as in the accelerometers, and then mounted on the instrument operating in a single cantilever mode. The experimental temperature range was set from 25 to 125 °C with an increment of 10 °C and an increase rate of 5 °C/min, and at each test point, 5 min was allowed for temperature stabilization and 0.1% strain was applied on the specimen for 20 min, followed by a 10 min recovery. The test results are shown in Figure 3.
The relaxation data, for normalization, were modeled by the master curve, which translates the curve segments at different temperatures to a reference temperature with logarithmic coordinates according to a time–temperature superposition [25]. The master curve can be fitted by a third-order polynomial function, such as:
l o g a T ( T )   =   C 1 ( T     T 0 )   +   C 2 ( T     T 0 ) 2   +   C 3 ( T     T 0 ) 3
where aT are the offset values at different temperatures (T1) and C1, C2 and C3 are constants.
The reference temperature was set at 25 °C, and then the three coefficients of the polynomial function were determined to be C1 = 0.223439, C2 = −0.00211 and C3 = 5.31163 × 10−6 (Figure 4).

4. Simulation and Experiments

The master curve in Figure 4 shows the relaxation behaviors of polymer adhesives under certain strain loads. This relaxed strain or stress results from the effective modulus of viscoelasticity, which can be described as a Prony series [26]:
E ( t )   =   σ ( t ) ε 0   =   E   +   i = 1 N E i exp ( t τ i ) ,   τ i   =   η i E i
where E(t) is the relaxation modulus; σ(t) is the stress; ε0 is the imposed constant strain; and E is the fully relaxed modulus. Ei and τi are referred to as a Prony pair; Ei is the elastic modulus; ηi is the viscosity; and τi is the relaxation time of ith Prony pair. N is the number of Prony pairs.
For this study, the master curve needs to be transformed into Prony series for modeling and experiments (Figure 5). The coefficients of Equation (6) with nine Prony pairs are listed in Table 2, where E0 is the instantaneous modulus when time is zero.
The simulation introduced the Prony series modulus into the whole finite element model (FEM) in ABAQUS software to acquire the output of the micro-accelerometers over time and temperature. The thermal experiment was carried out in an incubator with an accurate temperature controller. Each thermal test involved three micro-accelerometers mounted at a cube fixture (Figure 6). The full loading history used in both simulation and experiment is shown in Figure 7. The red-marked points represent the starting or ending points of a loading step. The analysis started at the curing temperature (60 °C, 0) at which the internal stress of the structure is zero. Then, the model was cooled to room temperature (25 °C, 1) with a rate of −5 °C/min and kept at that temperature for 60 min (2), and then the temperature was raised to a higher temperature with 60 min holding, followed by a temperature decrease to room temperature (3) with the same change rate and holding (4). The high temperature points were 50, 75 and 125 °C for the three groups of tests, respectively. The accelerometers in each group were subjected to three high–low temperature steps. The devices kept at room temperature after curing and cooling were also simulated and tested.
To investigate the time and temperature dependence of device performance, 40 FEM and packaged accelerometers were simulated and tested over the loading history of Figure 7, where the high temperature points were set to 50, 70 and 125 °C. Each thermal cycle was applied to ten accelerometers, and the remaining ten were kept at 25 °C for comparison. The zero offset and sensitivity of the accelerometers are shown in Figure 8. This shows great agreement between experimental and simulation data with small deviation, which is mainly caused by fabrication errors and temperature fluctuation, because the experimental data are the average value of each ten sensors’ results. Both the zero offset and sensitivity of the micro-accelerometers stored at room temperature decreased gradually over time, due to the thermal stress relaxation induced by the viscoelasticity of the polymer adhesive. For the 50 and 75 °C thermal cycles, higher temperature led to a higher offset and sensitivity, and the data of room temperature in each cycle also showed a decrease of offset and sensitivity. However, the 125 °C condition exhibited an increase of offset and sensitivity tested at room temperature.

5. Discussion

The observed output drift in the simulation and experiments indicates that the viscoelasticity of adhesive was the main cause of the deviation of zero offset and sensitivity. The underlying mechanism can be attributed to the time- and temperature-dependent stress and deformation states of the sensitive components of the micro-accelerometers. The residual compressive stress and tensile stress existed in the glass and the ceramic substrate, respectively, and because the CTE of ceramic material is larger than glass, the top and bottom interfaces of the adhesive layer exhibit different stress statuses. When the sensors were stored at room temperature, the residual stress in the adhesive gradually changed due to its relaxation induced by the viscoelastic property, and the stress in the chip experienced a corresponding shift to influence the deformation of sensitive components.
The stress relaxation of the adhesive at room temperature resulted in an expansion of the glass layer because of the compressive stress in it, so the distance of points P1 and P2 was extended (Figure 2), which led to a broadened gap d1 and a reduced displacement of proof mass based on Equation (3). The sensitivity and zero offset, therefore, decreased over time. In the thermal cycle experiments, the stress state in the chip changes with the loading process, including time and temperature effects. Take the experiment at 125 °C as an example; the key points of temperature change are marked in Figure 9. The displacement of point P1 is selected to explain the structural deformation of the sensitive components over time, and the temperature during heating and cooling processes (Figure 10). The detailed information can be concluded in the following steps:
  • Step 1—curing process: The initial state or stress-free state of the sensor appeared at 60 °C where the curing process started, and the P1 was located at position 0 in Figure 10a.
  • Step 2—cooling to room temperature: The point P1 moved to the center, the proof mass generated a positive movement along x direction and gap d1 decreased (Figure 10b). Thus, the offset and sensitivity both increased at this stage compared with those in Figure 10a.
  • Step 3—room temperature retention: The compression of glass decreased due to stress relaxation, and P1 slightly moved in the negative x direction, which led to the decrease of um and increase of d1 (Figure 10c). The offset and sensitivity decreased.
  • Step 4—starting point of high temperature: The model expanded, and the point P1 moved in the negative x direction substantially, which caused the decrease of um and increase of d1 (Figure 10d). Therefore, the offset and sensitivity continued to decrease.
  • Step 5—ending point of high temperature: During the thermal treatment process, the tension on the glass decreased due to stress relaxation, and P1 slightly moved in the positive x direction to result in a higher offset and sensitivity (Figure 10e).
  • Step 6—cooling to room temperature again: The model shrank, and the shrinkage included both the thermal part in step 4 and additional shrinkage value generated by strong viscoelasticity at 125 °C. Hence, the point P1 moved to the right position 1 (Figure 10f). Consequently, the offset and sensitivity at this stage were larger than those of Figure 10b.
  • Step 7—room temperature retention again: The offset and sensitivity decreased, due to stress relaxation, but they were still larger than those in Figure 10c. This indicated that the offset level is influenced by thermal treatment, so higher-temperature dwells lead to greater offset and sensitivity (Figure 10g).
For the accelerometers exposed to thermal cycles of 50 and 75 °C, the displacement pattern of point P1 is the same as that of 125 °C, but with a smaller value, because of the smaller expansion of structures.

6. Conclusions

The viscoelasticity effects of the epoxy-based die attach adhesive on the output performance of MEMS capacitive accelerometers over time and temperature were studied by simulation and experimental methods. The zero offset and sensitivity gradually decreased due to stress relaxation when accelerometers were kept at room temperature after adhesive packaging. In the same period, the high-temperature load slowed down the process of stress relaxation, and was not advantageous in improving the long-term stability related to viscoelasticity of packaging adhesives. Furthermore, the drift of bias and sensitivity can be attributed to the residual stress development induced by the viscoelastic behavior of adhesion materials. To aid in an in-depth understanding of the viscoelastic behavior of materials, future work will concentrate on developing the theoretical model of viscoelasticity of materials in the tri-layered assembly. Furthermore, the viscoelasticity difference induced by preparation and process will be studied to find out the solution to the drift of micro-devices.

Acknowledgments

This work was supported in part by NSAF (No. U1530132), National Natural Science Foundation of China (No. 51505068) and Fundamental Research Funds for the Central Universities (Grant Nos. ZYGX2015J085 and ZYGX2016J112).

Author Contributions

Wu Zhou, Peng Peng and Xiaoping He conceived and designed the idea and experiments; Peng Peng performed the experiments; Huijun Yu and Bei Peng analyzed the data; Wu Zhou and Peng Peng wrote the paper.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Higgins, A. Adhesive bonding of aircraft structures. Int. J. Adhes. Adhes. 2000, 20, 367–376. [Google Scholar] [CrossRef]
  2. Narisawa, M. Silicone resin applications for ceramic precursors and composites. Materials 2010, 3, 3518–3536. [Google Scholar] [CrossRef]
  3. Walwadkar, S.S.; Cho, J. Evaluation of die stress in MEMS packaging: Experimental and theoretical approaches. IEEE Trans. Compon. Packag. Technol. 2006, 29, 735–742. [Google Scholar] [CrossRef]
  4. Nysæ ther, J.B.; Larsen, A.; Liverød, B.; Ohlckers, P. Measurement of package-induced stress and thermal zero shift in transfer molded silicon piezoresistive pressure sensors. J. Micromech. Microeng. 1998, 8, 168. [Google Scholar] [CrossRef]
  5. Zarnik, M.S.; Rocak, D.; Macek, S. Residual stresses in a pressure-sensor package induced by adhesive material during curing: A case study. Sens. Actuators A Phys. 2004, 116, 442–449. [Google Scholar] [CrossRef]
  6. Song, J.; Huang, Q.A.; Li, M.; Tang, J.Y. Influence of environmental temperature on the dynamic properties of a die attached MEMS device. Microsyst. Technol. 2009, 15, 925–932. [Google Scholar] [CrossRef]
  7. Zhang, Z.; Wan, Z.; Liu, C.; Cao, G.; Lu, Y.; Liu, S. Effects of adhesive material on the output characteristics of pressure sensor. In Proceedings of the International Conference on Electronic Packaging Technology & High Density Packaging, Xi’an, China, 16–19 August 2010. [Google Scholar]
  8. Chuang, C.H.; Huang, Y.H.; Lee, S.L. The influence of adhesive materials on chip-on-board packing of MEMS microphone. Microsyst. Technol. 2012, 18, 1931–1940. [Google Scholar] [CrossRef]
  9. Joo, J.W.; Choa, S.H. Deformation behavior of MEMS gyroscope sensor package subjected to temperature change. IEEE Trans. Compon. Packag. Technol. 2007, 30, 346–354. [Google Scholar] [CrossRef]
  10. Peng, P.; Zhou, W.; Yu, H.; Peng, B.; Qu, H.; He, X. Investigation of the thermal drift of MEMS capacitive accelerometers induced by the overflow of die attachment adhesive. IEEE Trans. Compon. Packag. Manuf. Technol. 2016, 6, 822–830. [Google Scholar] [CrossRef]
  11. Guillemenet, J.; Bistac, S.; Schultz, J. Relationship between polymer viscoelastic properties and adhesive behaviour. Int. J. Adhes. Adhes. 2002, 22, 1–5. [Google Scholar] [CrossRef]
  12. Obaid, N.; Kortschot, M.T.; Sain, M. Understanding the stress relaxation behavior of polymers reinforced with short elastic fibers. Materials 2017, 10, 472. [Google Scholar] [CrossRef] [PubMed]
  13. Srikanth, N. Warpage analysis of epoxy molded packages using viscoelastic based model. J. Mater. Sci. 2006, 41, 3773–3780. [Google Scholar] [CrossRef]
  14. Zhang, X.; Park, S.; Judy, M.W. Accurate assessment of packaging stress effects on MEMS sensors by measurement and sensor-package interaction simulations. J. Microelectromech. Syst. 2007, 16, 639–649. [Google Scholar] [CrossRef]
  15. Krondorfer, R.H.; Kim, Y.K. Packaging effect on MEMS pressure sensor performance. IEEE Trans. Compon. Packag. Technol. 2007, 30, 285–293. [Google Scholar] [CrossRef]
  16. Park, S.; Liu, D.; Kim, Y.; Lee, H.; Zhang, S. Stress evolution in an encapsulated MEMS package due to viscoelasticity of packaging materials. In Proceedings of the IEEE 62nd Electronic Components and Technology Conference (ECTC), San Diego, CA, USA, 29 May–1 June 2012. [Google Scholar]
  17. Kim, Y.; Lee, H.; Zhang, X.; Park, S. Optimal material properties of molding compounds for MEMS package. IEEE Trans. Compon. Packag. Manufac. Technol. 2014, 4, 1589–1597. [Google Scholar]
  18. Kim, Y.; Liu, D.; Lee, H.; Liu, R.; Sengupta, D.; Park, S. Investigation of stress in MEMS sensor device due to hygroscopic and viscoelastic behavior of molding compound. IEEE Trans. Compon. Packag. Manufac. Technol. 2015, 5, 945–955. [Google Scholar] [CrossRef]
  19. Zhou, W.; Yu, H.; Peng, B.; Shen, H.; He, X.; Su, W. Modeling the microstructure curvature of boron-doped silicon in bulk micromachined accelerometer. Materials 2013, 6, 244–254. [Google Scholar] [CrossRef] [PubMed]
  20. Zhou, W.; Chen, L.; Yu, H.; Peng, B.; Chen, Y. Sensitivity jump of micro accelerometer induced by micro-fabrication defects of micro folded beams. Meas. Sci. Rev. 2016, 16, 228–234. [Google Scholar] [CrossRef]
  21. Dai, G.; Li, M.; He, X.; Du, L.; Shao, B.; Su, W. Thermal drift analysis using a multiphysics model of bulk silicon MEMS capacitive accelerometer. Sens. Actuators A Phys. 2011, 172, 369–378. [Google Scholar] [CrossRef]
  22. He, J.; Xie, J.; He, X.; Du, L.; Zhou, W. Analytical study and compensation for temperature drifts of a bulk silicon MEMS capacitive accelerometer. Sens. Actuators A Phys. 2016, 239, 174–184. [Google Scholar] [CrossRef]
  23. Suhir, E. Predictive analytical thermal stress modeling in electronics and photonics. Appl. Mech. Rev. 2009, 62, 933–944. [Google Scholar] [CrossRef]
  24. Chae, S.H.; Zhao, J.H.; Edwards, D.R.; Ho, P.S. Characterization of the viscoelasticity of molding compounds in the time domain. J. Electron. Mater. 2010, 39, 419–425. [Google Scholar] [CrossRef]
  25. Hu, M.; Xia, Y.; Daeffler, C.S.; Wang, J.; McKenna, G.B.; Kornfield, J.A.; Grubbs, R.H. The linear rheological responses of wedge-type polymers. J. Polym. Sci. Part B Polym. Phys. 2015, 53, 899–906. [Google Scholar] [CrossRef]
  26. Kim, Y.K.; White, S.R. Stress relaxation behavior of 3501-6 epoxy resin during cure. Polym. Eng. Sci. 2010, 36, 2852–2862. [Google Scholar] [CrossRef]
Figure 1. Structure of capacitive accelerometer. (a) Diagram of accelerometer; (b) SEM structure.
Figure 1. Structure of capacitive accelerometer. (a) Diagram of accelerometer; (b) SEM structure.
Materials 10 01077 g001
Figure 2. Half-structure of sensitive components.
Figure 2. Half-structure of sensitive components.
Materials 10 01077 g002
Figure 3. Stress–relaxation test results.
Figure 3. Stress–relaxation test results.
Materials 10 01077 g003
Figure 4. Master curve with reference temperature of 25 °C.
Figure 4. Master curve with reference temperature of 25 °C.
Materials 10 01077 g004
Figure 5. Prony series fitted to master curve.
Figure 5. Prony series fitted to master curve.
Materials 10 01077 g005
Figure 6. Mounted accelerometers in the test.
Figure 6. Mounted accelerometers in the test.
Materials 10 01077 g006
Figure 7. Loading history for the analysis.
Figure 7. Loading history for the analysis.
Materials 10 01077 g007
Figure 8. Results comparison. (a) Bias; (b) sensitivity.
Figure 8. Results comparison. (a) Bias; (b) sensitivity.
Materials 10 01077 g008
Figure 9. The first thermal cycle process at 125 °C.
Figure 9. The first thermal cycle process at 125 °C.
Materials 10 01077 g009
Figure 10. The moving trail of point P1 at each step in the first thermal cycle at 125 °C. (a) Curing process; (b) cooling to room temperature; (c) room temperature retention; (d) starting point of high temperature; (e) ending point of high temperature; (f) cooling to room temperature again; (g) room temperature retention again.
Figure 10. The moving trail of point P1 at each step in the first thermal cycle at 125 °C. (a) Curing process; (b) cooling to room temperature; (c) room temperature retention; (d) starting point of high temperature; (e) ending point of high temperature; (f) cooling to room temperature again; (g) room temperature retention again.
Materials 10 01077 g010
Table 1. Material properties for the sensor.
Table 1. Material properties for the sensor.
MaterialYoung’s Modulus (Gpa)Poisson RatioCTE (ppm/°C)
Silicon1600.222.6
Glass62.70.23.25
Ceramic3600.226.5
AdhesiveTable 20.3760
Table 2. Prony pairs of the die attach adhesive.
Table 2. Prony pairs of the die attach adhesive.
iEi/E0 1 τ i
10.085103041.87694
20.14589981,765.85865
30.22654243.32699
40.112482083.25650
50.1590648,993.21024
60.2161731.16988
70.039235052.23180
80.000256992.77554
90.006763321.33054
1 E0 = 2744.76252 MPa.

Share and Cite

MDPI and ACS Style

Zhou, W.; Peng, P.; Yu, H.; Peng, B.; He, X. Material Viscoelasticity-Induced Drift of Micro-Accelerometers. Materials 2017, 10, 1077. https://0-doi-org.brum.beds.ac.uk/10.3390/ma10091077

AMA Style

Zhou W, Peng P, Yu H, Peng B, He X. Material Viscoelasticity-Induced Drift of Micro-Accelerometers. Materials. 2017; 10(9):1077. https://0-doi-org.brum.beds.ac.uk/10.3390/ma10091077

Chicago/Turabian Style

Zhou, Wu, Peng Peng, Huijun Yu, Bei Peng, and Xiaoping He. 2017. "Material Viscoelasticity-Induced Drift of Micro-Accelerometers" Materials 10, no. 9: 1077. https://0-doi-org.brum.beds.ac.uk/10.3390/ma10091077

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop