Article

Application of Additively Manufactured Pentamode Metamaterials in Sodium/Inconel 718 Heat Pipes

Laboratory of Aero-Thermal Protection Technology for Aerospace Vehicles, China Academy of Aerospace Aerodynamics, Beijing 100074, China
*
Author to whom correspondence should be addressed.
Submission received: 15 April 2021 / Revised: 18 May 2021 / Accepted: 29 May 2021 / Published: 2 June 2021
(This article belongs to the Special Issue Material Design and Defect Control for Metal Additive Manufacturing)

Abstract

:
In this study, pentamode metamaterials were proposed for thermal stress accommodation of alkali metal heat pipes. Sodium/Inconel 718 heat pipes with and without pentamode metamaterial reinforcement were designed and fabricated. Then, these heat pipes were characterized by startup tests and thermal response simulations. It was found that pentamode metamaterial reinforcement did not affect the startup properties of sodium/Inconel 718 heat pipes. At 650–950 °C heating, there was a successful startup of heat pipes with and without pentamode metamaterial reinforcement, displaying uniform temperature distributions. A further simulation indicated that pentamode metamaterials could accommodate thermal stresses in sodium/Inconel 718 heat pipes. With pentamode metamaterial reinforcement, stresses in the heat pipes decreased from 12.9–62.1 to 10.2–52.4 MPa. As a result, sodium/Inconel 718 heat pipes could be used more confidently. This work was instructive for the engineering application of alkali metal heat pipes.

1. Introduction

Heat pipes, combining the advantages of high conductivity and inherent safety, are attractive devices for thermal management of hot structures, such as large-scale heat exchangers, thermal protection of hypersonic vehicles, heat radiation of space reactors and so on [1,2,3,4]. For these applications, alkali metal heat pipes were feasible for source temperatures above 600 °C. Power throughputs of 15 kW/cm2 were possible for sodium heat pipes operated at 880 °C [5].
The feasibility of alkali metal heat pipes has been demonstrated by various researchers. Rosenfeld and his co-workers [6,7] evaluated sodium/Inconel 718 heat pipes for use as heat exchangers by 10 year life tests. For over 87,000 h at nearly 700 °C, no significant degradation of screen wicks or Inconel 718 walls were observed, providing strong evidence for chemical compatibility between sodium and Inconel 718 alloy. Camarda [8,9] fabricated sodium heat pipes for thermal protection of hypersonic vehicles. He verified that sodium heat pipes cooled leading edges sufficiently enough, allowing the use of nickel-based superalloys. Then, a leading edge-like heat pipe was fabricated, which reduced stagnation temperatures from 1926 to 900 °C [10,11]. Dussinger and his co-workers [12] fabricated alkali metal heat pipes as space radiators. Their experimental results implied that the capacity of potassium heat pipes was 5–15 kW, being larger than that of cesium heat pipes. However, severe temperature gradients were generated in the startup process of the above-mentioned alkali metal heat pipes, which might lead to thermal stresses and undesirable deformations.
The purpose of this study was to accommodate thermal stresses in alkali metal heat pipes. With thermal stress accommodation, undesirable deformations of heat pipes were reduced. Consequently, alkali metal heat pipes could be used more confidently in high temperature conditions. This study was meaningful for the development of advanced heat pipes, especially for that of advanced heat pipe spreaders [13,14,15].
In this study, additively manufactured pentamode metamaterials were proposed for thermal stress accommodation of alkali metal heat pipes. Sodium/Inconel 718 heat pipes with and without pentamode metamaterial reinforcement were designed and fabricated at the China Academy of Aerospace Aerodynamics (CAAA). Then, these heat pipes were characterized by startup tests and thermal response simulations. Finally, thermal stresses in fabricated sodium/Inconel 718 heat pipes were analyzed.

2. Experimental

Figure 1 shows the illumination of a heat pipe operation [16]. In Figure 1, the startup process was as follows: Heat was absorbed by the evaporator of the heat pipe. The working fluid evaporated, leading to an internal pressure between the evaporator and the condenser. Then, vapor flew down to the condenser and gave up heat. Finally, the liquid working fluid returned to the evaporator via a capillary wick. During the startup processes, severe temperature gradients and thermal stresses were produced, which was detrimental to the engineering applications of the alkali metal heat pipes.
Concepts of pentamode metamaterials were proposed as early as 1995. In 2012, additive manufacturing enabled the realization of such light-weighted materials. Compared with traditional materials, the mechanical properties of pentamode metamaterials were linked to their macro-topology. With macro-topology adjustment, a negative thermal expansion and negative Poisson’s ratio were achieved [17,18,19]. Thus, thermal stresses and strains in structures might be accommodated by pentamode metamaterial reinforcement.

2.1. Design of Heat Pipes With and Without Reinforcement

Heat pipes with dimensions of Φ25 × 500 mm were designed at our company. For the working fluid, 99.9% pure sodium was used. Inconel 718 and GH4169 (two kinds of nickel-based superalloys) were candidate materials of heat pipe walls and pentamode metamaterials. For additive manufacturing, only Inconel 718 powders were commercially obtained. Hence, Inconel 718 was used as the raw material of the heat pipes. The chemical compositions of Inconel 718 are listed in Table 1. Annular gaps with dimensions of 0.5 mm × 0.5 mm (width × height) were used as capillary wicks.
Figure 2 shows the illumination of the designed heat pipes with and without pentamode metamaterial reinforcement. In Figure 2a, the designed heat pipes included an Inconel 718 wall, two endcaps, capillary wick (annular gaps), sodium, and pentamode metamaterial reinforcement. The Inconel 718 wall and endcaps were 1.5 mm in thickness. The capillary wick was 36 annular gaps, distributed evenly on the inner surface of the heat pipe wall. The topology of reinforcement was a lattice structure based on cubic unit cells with struts so as to form metamaterials. The cubic unit cells were 7 mm × 7 mm × 7 mm (length × width × height). The struts were 0.5 mm in diameter. Moreover, sodium/Inconel 718 heat pipes without pentamode metamaterial reinforcement were also designed, as seen in Figure 2b. In Figure 2b, the Inconel 718 wall, endcaps, and capillary wick were identical to that in Figure 2a.

2.2. Fabrication of Heat Pipes with and without Reinforcement

Sodium/Inconel 718 heat pipes were fabricated by the following process: (1) Inconel 718 walls with and without pentamode metamaterial reinforcement were additively manufactured by selective laser melting (Realizer SLM 125, Germany), and annular gaps were in situ formed on the inner surface of the heat pipe walls; (2) endcaps were machined using bulk Inconel 718 alloy; (3) Inconel 718 walls and endcaps were ultrasonically cleaned by acetone, ethanol, and de-ionized water, and then overnight dried in a 70° C oven; (4) an endcap was welded into the Inconel 718 wall, obtaining heat pipe shells for sodium charging; (5) sodium charging was performed via a vacuum/argon facility [20]; and (6) the other endcap was equipped on heat pipe shells, and then seal welded in a vacuum environment.
Four models of sodium/Inconel 718 heat pipes were fabricated, as seen in Table 2. In Table 2, HP1 and HP3 were with pentamode metamaterial reinforcement, while HP2 and HP4 were without pentamode metamaterial reinforcement. The amounts of 16 and 20 g sodium were charged into the heat pipes, with a corresponding charging ratio of 8 and 10%, respectively. The densities of HP1–HP4 were 2.02–2.04 g/cm3, being very close to each other. Pentamode metamaterial reinforcement displayed a negligible impact on model weight.
To ensure the amount of sodium charging, all the fabricated heat pipes (HP1–HP4) were weighted and inspected by X-ray. Then, these heat pipes were heated in a 600 °C oven, redistributing charged sodium uniformly in the wicks. Figure 3a shows an optical image of a fabricated heat pipe (HP1) and its cross section.

2.3. Characterization

2.3.1. Startup Tests

Thermocouples (TCs) were used for the axial temperature checking of heat pipes. In this study, 6 K-type TCs were spot welded at regular intervals of 90 mm, as seen in Figure 3b. The diameter of these TCs were 250 μm. Before the startup tests, they were calibrated with an accuracy of ±7.5 °C.
Figure 4 shows a schematic diagram of the 30 kW calorifier and startup tests. In Figure 4, the calorifier was Φ300 mm × 300 mm. The porous Al2O3 container was 50 mm in thickness. A graphite oven was used as a radiator. During the startup tests, the graphite oven was heated to temperatures of 650–950 °C. Then, the evaporator of the heat pipe (250 mm long from one endcap) was inserted into the oven to check the thermal response of all the TCs.
In this study, sodium/Inconel 718 heat pipes were tested as follows: (1) heated at a temperature of 650 °C; (2) heated at a temperature of 750 °C; (3) heated at a temperature of 850 °C; and (4) heated at a temperature of 950 °C.

2.3.2. Thermal Response Simulation

An engineering method, named as the flat-front model, was used to simulate the thermal response of sodium/Inconel 718 heat pipes. In this model, all the nodes were divided according to heating characteristics, and the flat-front position was determined by the local energy conservation theory. Details about the flat-front model and its simulation can be found elsewhere [21].
Based on the flat-front model, an in-house software, named as thermal analysis heat pipe (TAHP), was developed for the thermal response simulation [22]. During the thermal response simulation, both thermal radiation and convective cooling were considered. Emissivity (ε) of thermal radiation was assumed to be 0.9 (emissivity of Al2O3 scale formed on the heat pipe surfaces). Film coefficient (h) of convective cooling was assumed to be 20 W·m−2·°C−1 (film coefficient of Inconel 718).
The thermal response of the sodium/Inconel 718 heat pipes indicated that the simulated results agreed well with the startup results, identifying the validity of the flat-front model. Then, an endcap surface was fixed supported, calculating the thermal stresses and deformation of sodium/Inconel 718 heat pipes. Finally, the stress concentration in the heat pipes was analyzed, and the effects of pentamode metamaterial reinforcement were discussed.

3. Results and Discussion

3.1. Startup Results

HP1 and HP2 were heated at 850 °C, and their optical images are shown in Figure 5. In Figure 5a, we can see that HP1 displayed a bright evaporator, bright adiabatic, and dark condenser, indicating the existence of asymmetric heating. In contrast, HP2 displayed a bright evaporator, bright adiabatic, and bright condenser, as seen in Figure 5b. Therefore, HP2 displayed a more uniform temperature distribution. This was most probably caused by the startup of HP2, transferring heat efficiently from the evaporator to the adiabatic and the condenser [23].
Figure 6 shows the startup results of HP1 and HP2 at 850 °C heating. In Figure 6a, HP1 was heated for 600 s. In the initial 0–150 s, the temperatures of TC1–TC4 increased greatly to 700–750 °C. The temperatures of TC5 and TC6 were about 600 and 22 °C, being significantly lower than that of TC1–TC4. In the following 150–600s heating, TC1–TC6 displayed temperature differences (ΔT) of 450–800 °C, indicating that startup failures occurred for HP1. In Figure 6b, the successful startup of HP2 is shown. In the initial 0–130 s, all the TC temperatures increased greatly to an identical value of ~600 °C. Then, these temperatures increased gradually to ~830 °C in the following tests. For sodium charging of 8%, it appeared that sodium/Inconel 718 heat pipes without pentamode metamaterial reinforcement showed better startup properties.
In Figure 6a, a noticeable bump occurred in the TC1 measurement. A possible explanation was that excessive gas remained in HP1 (as seen in Section 3.3.1). In the initial 0–80 s of heating, the heat was absorbed by sodium evaporation. An internal pressure formed between the evaporator and the condenser. However, this pressure was lower than the remaining gas pressure. Sodium vapor could not flow from the evaporator to the condenser. The temperatures of TC1–TC4 increased greatly, especially for that of HP1. In the following 80–600 s of heating, the internal pressure was higher than the remaining gas pressure. Sodium vapor flew from the evaporator to the condenser. The temperatures of TC1–TC4 became close to each other. Therefore, a noticeable bump occurred in the TC1 measurement.
Figure 7 shows the startup results of HP3 and HP4 at 850 °C heating. In Figure 7, the successful startup of both HP3 and HP4 is shown. After 200–300 s of heating, the two heat pipes displayed uniform temperatures of 800–830 °C. It was noted that the startup time of HP3 was longer than that of HP4. This was probably caused by pentamode metamaterial reinforcement, which might increase the startup temperature and elongate the startup time of sodium/Inconel 718 heat pipes [23,24]. Details of this phenomenon are discussed in Section 3.3.1.
HP2, HP3, and HP4 were heated at 650, 750, 850, and 950 °C, respectively. Their startup properties are shown in Figure 8. At 650–950 °C heating, the temperature difference (ΔT) of HP2–HP4 was kept at 30–50 °C, but power throughputs increased from 1.6 to 4.8 kW. As HP2–HP4 displayed similar startup properties, it was concluded that pentamode metamaterial reinforcement had negligible impact on the startup properties of heat pipes.
Figure 9 shows optical images of tested HP1–HP4. In Figure 9, we can see that all tested heat pipes still kept their integrity. Structure failures or sodium leakage were not found. At 650–950 °C heating, thermal stresses in sodium/Inconel 718 heat pipes would be lower than the strength of the Inconel 718 alloy.

3.2. Simulation Results

HP3 and HP4 were selected for the thermal response simulation because of their identical sodium charging ratio. According to the flat-front model and heating characteristics, hex-dominant mesh was applied for HP3 and HP4. The maximum grid size was 5 × 10−3 m. The parameters of the thermal response are listed in Table 3. Figure 10 shows thermal stresses (Mises) in sodium/Inconel 718 heat pipes at 850 °C heating. For the HP3 startup, an area of stress concentration was produced in the heat pipe wall. Then, this area moved directly to the endcap around the condenser. Maximum stresses of 29.2 MPa appeared in the location of TC6. For the HP4 startup, an area of stress concentration was also produced and then moved to the endcap. The maximum stresses located in TC6 were 40.7 MPa, being higher than that in HP3. Thus, it was concluded that pentamode metamaterials could accommodate thermal stresses in sodium/Inconel 718 heat pipes. A further investigation indicated that this accommodation was related to pentamode metamaterial reinforcement (as seen in the zoomed-in images in Figure 10), which are discussed in Section 3.3.2.
Figure 11 shows Mises stresses located in TC6 of the sodium/Inconel 718 heat pipes. Mises stresses were unidirectional. At 650 °C heating, Mises stresses in HP3 were 10.2 MPa. At 750, 850, and 950 °C heating, Mises stresses in HP3 increased to 16.0, 29.2, and 52.4 MPa, respectively. On the other hand, Mises stresses in HP4 were 12.9–62.1 MPa, being about 30% higher than that in HP3. With stress accommodation, sodium/Inconel 718 heat pipes with pentamode metamaterial reinforcement (HP3) could be used more confidently.
Figure 12 shows the axial deformation of HP3 and HP4 at 650–950 °C heating. The direction of the axial deformation was from the evaporator to the condenser (from TC1 to TC6). In Figure 12, we can see that pentamode metamaterial reinforcement did not affect axial deformation of sodium/Inconel 718 heat pipes. At 650 °C heating, the axial deformation of HP3 was 5.07 mm. As the heating temperature rose, the axial deformation of HP3 increased linearly to 8.01 mm. Moreover, the axial deformation of HP4 was almost the same as that of HP3. This was beneficial for engineering applications of sodium/Inconel 718 heat pipes with pentamode metamaterial reinforcement.

3.3. Discussion

3.3.1. Startup Temperatures

According to previous studies [23,25], the saturation pressure of sodium heat pipes was calculated by the following equation:
lg P s = A B T
where P s is the saturation pressure of sodium (×105 Pa); T is the operating temperature of the sodium heat pipes (K); and A and B are constant, equal to 4.544579 and 5242.1, respectively. The startup temperatures (T*) of the sodium heat pipes were determined by the following equation [25]:
T * = 2 π d 2 K n P s D v 1.051 κ
where d is the effective molecular diameter of sodium, equal to 3.567 × 10−10 m; Kn is the Knudsen number, equal to 0.01; Dv is the vapor passage diameter or equivalent vapor passage diameter, m; and κ is the Stefan–Boltzmann constant, equal to 5.67 × 10−8 W·m−2·K−4. The calculated startup temperatures of HP2–HP4 were 417, 426, and 417 °C, respectively. These temperatures were lower than the heating temperatures in Section 2.3.1. As a result, there was a successful startup of sodium/Inconel 718 heat pipes in the startup tests.
During the process of startup tests, heat was absorbed by evaporation of liquid sodium. This evaporation resulted in an internal pressure between the evaporator and the condenser, which caused the vapor to flow down to the condenser and give up heat. However, pentamode metamaterial reinforcement could slow down the vapor flow from the evaporator to the condenser. Consequently, the startup temperature of HP3 became higher than that of HP2 and HP4, and the startup time was elongated. A further examination implied that excessive gas remained in the shell of HP1, leading to startup failures of the sodium/Inconel 718 heat pipe.

3.3.2. Effects of Pentamode Metamaterial Reinforcement

Table 4 lists the high temperature strength of Inconel 718 alloy [26]. At heating temperatures of 650–950 °C, the strength of the Inconel 718 alloy was 109–970 MPa. These values are greater than the thermal stresses in Section 3.2. Therefore, all tested heat pipes still kept their integrity.
According to Equation (1), we know that sodium pressure (Ps) in this study was about 4.6 × 104 Pa, being lower than atmosphere pressure (1.0 × 105 Pa). Consequently, a pressure of 5 MPa was put on the outside walls of HP3 and HP4, illuminating the effects of pentamode metamaterial reinforcement. Elastic strains of HP3 and HP4 were transiently simulated in the in-house software of thermal analysis heat pipe (TAHP), as seen in Figure 13. In Figure 13, the elastic strains of HP4 were 2.37 × 10−4 mm/mm. With pentamode metamaterial reinforcement, elastic strains of HP3 reduced to 1.99 × 10−4 mm/mm. Moreover, uniform strains were produced in the reinforcement. With elastic strain reduction, stresses in the heat pipes were accommodated.
The effects of pentamode metamaterial reinforcement were probably as follows: During startup tests, heat was transferred from the evaporator to the condenser. Stress concentration and elastic strains were produced in an area of the heat pipe walls. This area moved from the evaporator to the condenser. With pentamode metamaterial reinforcement, elastic strains occurred not only in the heat pipe walls but also in the reinforcement, as seen in the zoomed-in images in Figure 10. Because Poisson’s ratio of pentamode metamaterials was negative, strain areas in the reinforcement were larger than that in the heat pipe walls [19,27,28]. Therefore, stresses in the heat pipes were accommodated. On the other hand, strain variation did not affect the deformation of heat pipes, as HP3 and HP4 showed identical axial deformation.

3.3.3. Future Applications

According to above analysis, it was demonstrated that pentamode metamaterial reinforcement could accommodate thermal stresses in sodium/Inconel 718 heat pipes; hence, this was a solution to the thermal-structure problems of alloys. Other potential applications (using different topological structures and different heat pipes) included: limiting thermal distortions of hot structures [28], cooling of space reactors, and thermal management of hypersonic vehicles. Recently, heat pipes with pentamode reinforcement were designed for space reactor cooling.

4. Conclusions

In this study, pentamode metamaterials were proposed for thermal stress accommodation of alkali metal heat pipes. Sodium/Inconel 718 heat pipes with and without pentamode metamaterial reinforcement were designed and fabricated. These heat pipes were characterized by startup tests and thermal response simulations. Based on the experimental and theoretical results, the following conclusions were drawn:
(1)
Pentamode metamaterial reinforcement displayed a negligible impact on model weight. The densities of HP1–HP4 were 2.02–2.04 g/cm3, being very close to each other.
(2)
The startup temperatures of HP2–HP4 were 417, 426, and 417 °C, being lower than the heating temperatures. During the startup tests, there was a successful startup of these heat pipes.
(3)
Excessive gas remained in the shell of HP1, leading to startup failures of sodium/Inconel 718 heat pipes.
(4)
Pentamode metamaterials could accommodate thermal stresses in sodium/Inconel 718 heat pipes. With pentamode metamaterial reinforcement, thermal stresses in the heat pipes reduced from 12.9–62.1 to 10.2–52.4 MPa.
(5)
With thermal stress accommodation, sodium/Inconel 718 heat pipes could be used more confidently.

Author Contributions

Conceptualization, L.H. and X.L.; methodolody, K.S.; software, J.Y.; validation, B.A.; investigation, C.L. All authors have read and agreed to the published version of the manuscript.

Funding

This reaearch received no external funding.

Institutional Review Board Statement

The study was conducted according to the guidelines of the Declaration of Helsinki, and approved by the Institutional Review Board.

Informed Consent Statement

Informed consent was obtained from all subjects involved in the study.

Data Availability Statement

The data presented in this study are available on request from the corresponding author.

Acknowledgments

Authors thank Xuejun Zhang for his suggestion and written permission on this article.

Conflicts of Interest

The authors declare no conflict of interest.

Nomenclature

D v vapor passage diameter or equivalent vapor passage diameter, m
HPheat pipe
h film coefficient of convective cooling, 20 W/(m2·°C)
K n Knudsen number
P s saturation pressure of heat pipe, Pa
T operating temperature, K or °C
T * startup temperature of sodium heat pipes, K or °C
T C s thermocouples
t time, s
Δ T temperature difference, K/°C
ε emissivity of heat pipe surface, 0.9
κ Stefan–Boltzmann constant, 5.67 × 10−8 W·m−2·K−4
Subscripts
s saturation
v vapor

References

  1. Alario, J.P.; Prager, R.C. Space Shuttle Orbit Heat Pipe Application; NASA CR-128498; AIAA Committee: Reston, VA, USA, 1972. [Google Scholar]
  2. Niblock, G.A.; Reeder, J.C.; Huneidi, F. Four space shuttle wing leading edge concepts. J. Spacec. Rocket 1974, 11, 314–320. [Google Scholar] [CrossRef]
  3. Anderson, W.G.; Bonner, R.W.; Dussinger, P.M.; Hartenstine, J.R.; Sarraf, D.B. Intermediate temperature fluids life tests-experiments. In Proceedings of the 5th International Energy Conversion Engineering Conference and Exhibit (IECEC), St. Louis, MO, USA, 25–27 June 2007. [Google Scholar]
  4. El-Genk, M.S.; Jong, T.S. An analysis of the effect of external heating on the SP-100 system radiator heat pipes. In Proceedings of the 23rd Intersociety Energy Conversion Engineering Conference, Denver, CO, USA, 31 July–5 August 1988. [Google Scholar]
  5. Tournier, J.M.; El-Genk, M.S. Startup of a horizontal lithium-molybdnum heat pipe from a frozen state. Int. J. Heat Mass Transf. 2003, 46, 671–685. [Google Scholar] [CrossRef]
  6. Rosenfeld, H.J.; Ernst, D.M.; Lindemuth, J.E.; Sanzi, J.L.; Geng, S.M.; Zuo, J. An Overview of Long Duration Sodium Heat Pipe Tests R.; Thermacore International, Inc.: Lancaster, PA, USA, 2004. [Google Scholar]
  7. Rosenfeld, J.H.; Minnerly, K.G.; Dyson, C.M. Ten Year Operating Test Results and Post-Test Analysis of a 1/10 Segment Stirling Sodium Heat Pipe Phase III Final Report, R.; Thermacore, Inc.: Lancaster, PA, USA, 2012. [Google Scholar]
  8. Camarda, C.J. Analysis and Radiant Heat Tests of a Heat-Pipe-Cooled Leading Edge; NASA TN D-8468; AIAA Committee: Reston, VA, USA, 1977. [Google Scholar]
  9. Camarda, C. Aerothermal Tests of a Heat Pipe Cooled Leading Edge at Mach 7; NASA TP-1320; AIAA Committee: Reston, VA, USA, 1978. [Google Scholar]
  10. Boman, B.L.; Citrin, K.H.; Garner, E.C.; Stone, J.E. Heat Pipes for Leading Edges of Hypersonic Vehicles; NASA CR-181922; AIAA Committee: Reston, VA, USA, 1989. [Google Scholar]
  11. Boman, B.; Elias, T. Tests of a sodium/Hastelloy X wing leading edge heat pipe for hypersonic vehicles. In Proceedings of the AIAA/ASME 5th Joint Thermophysics and Heat Transfer Conference, Seattle, WA, USA, 18–20 June 1990. [Google Scholar]
  12. Dussinger, P.M.; Anderson, W.G.; Sunada, E.T. Design and testing of titanium/cesium and titanium/potassium heat pipes. In Proceedings of the 3rd International Energy Conversion Engineering Conference, San Francisco, CA, USA, 15–18 August 2005. [Google Scholar]
  13. Ai, B.C.; Yu, J.J.; Chen, S.Y.; Lu, Q.; Han, H.T.; Hu, L.F. Fabrication and testing of lithium/C-103 alloy heat pipe for sharp leading edge cooling. Heat Mass Transf. 2018, 54, 1359–1366. [Google Scholar] [CrossRef]
  14. Steeves, C.A.; He, M.Y.; Kasen, S.D.; Valdevit, L.; Wadley, H.N.G.; Evans, A.G. Feasibility of metallic structural heat pipes as sharp leading edges for hypersonic vehicles. J. Appl. Mechan. 2019, 76, 1–9. [Google Scholar] [CrossRef] [Green Version]
  15. Chu, M.; Lu, Q.; Han, H.T.; Hu, L.F.; Yu, J.J.; Ai, B.C. Fabrication of sodium/Inconel/718 heat pipes for combustor cooling. Micrograv. Sci. Technol. 2019, 31, 783–791. [Google Scholar] [CrossRef]
  16. Glass, D.E.; Camarda, C.J. Fabrication and testing of a leading edge-shaped heat pipe. J. AIAA 1999, 36, 921–923. [Google Scholar] [CrossRef] [Green Version]
  17. Lee, J.H.; Singer, J.P.; Thomas, E.L. Micro-/nanostructured mechanical metamaterials. Adv. Mater. 2012, 24, 4782–4810. [Google Scholar] [CrossRef] [PubMed]
  18. Zadpoor, A.A. Mechanical meta-materials. Mater. Horiz. 2016, 3, 371–378. [Google Scholar] [CrossRef] [Green Version]
  19. Yan, C.; Hao, L.; Hussein, A.; Young, P.; Raymont, D. Advanced light-weight 316L stainless steel cellular lattice structures fabricated via selective laser melting. Mater. Des. 2014, 55, 533–541. [Google Scholar] [CrossRef] [Green Version]
  20. Lu, Q.; Han, H.T.; Hu, L.F.; Chen, S.Y.; Yu, J.J.; An, B.C. Preparation and testing of nickel-based superalloy/sodium heat pipes. Heat Mass Trans. 2017, 53, 3391–3397. [Google Scholar] [CrossRef]
  21. Faghri, A. Heat Pipe Science and Technology; Second Version; University of Connecticut: Storrs, CT, USA, 2016; ISBN 978-0-9842760-1-1. [Google Scholar]
  22. Deng, D.Y.; Chen, S.Y.; Ai, B.C.; Qu, W.; Yu, J.J. Calculation investigation of high-temperature heat pipe startup of sharp leading edge. Acta Aerodyn. Sin. 2016, 34, 646–651. (In Chinese) [Google Scholar]
  23. Chen, S.Y.; Han, H.T.; Shi, J.T.; Lu, Q.; Hu, L.F.; Ai, B.C. Applications of sodium/GH4099 heat pipes for nose cap cooling. Micrograv. Sci. Technol. 2019, 31, 417–424. [Google Scholar] [CrossRef]
  24. Cao, Y.; Faghri, A. A numerical analysis of high-temperature heat pipe startup from the frozen state. J. Heat Transf. 1993, 115, 247–254. [Google Scholar] [CrossRef]
  25. Dickinson, T.J. Performance Analysis of a Liquid Metal Heat Pipe Space Shuttle Experiment. Master’s Thesis, The Graduate School of Engineering of the Air Force Institute of Technology, Wright-Patterson AFB, Montgomery County, OH, USA, December 1996. [Google Scholar]
  26. Yan, M.G.; Liu, B.C.; Li, J.G.; Wu, S.P.; Hua, J.; Xu, B.L.; Li, C.G.; Zeng, F.C.; Wu, X.R.; Zhou, X.R.; et al. China Aeronautical Material Handbook, 2nd ed.; Published by China Standard Committee: Beijing, China, 2002; pp. 323–360. ISBN 7-5066-2439-7. (In Chinese) [Google Scholar]
  27. Campanelli, S.L.; Contuzzi, N.; Ludovico, A.D.; Caiazzo, F.; Cardaropoli, F.; Sergi, V. Manufacturing and characterization of Ti6Al4V lattice components manufactured by selective laser melting. Materials 2014, 7, 4803–4822. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  28. Razavykia, A.; Brusa, E.; Delprete, C.; Yavari, R. An overview of additive manufactury technologies-a review of technical synthesis in numerical study of selective laser melting. Materials 2020, 13, 3895. [Google Scholar] [CrossRef] [PubMed]
Figure 1. Illumination of a heat pipe operation, reference [16].
Figure 1. Illumination of a heat pipe operation, reference [16].
Materials 14 03016 g001
Figure 2. Illumination of designed heat pipes: (a) with pentamode metamaterial reinforcement, (b) without pentamode metamaterial reinforcement.
Figure 2. Illumination of designed heat pipes: (a) with pentamode metamaterial reinforcement, (b) without pentamode metamaterial reinforcement.
Materials 14 03016 g002
Figure 3. An optical image of a fabricated heat pipe (a) and the thermocouples’ location (b).
Figure 3. An optical image of a fabricated heat pipe (a) and the thermocouples’ location (b).
Materials 14 03016 g003
Figure 4. Schematic diagram of 30 kW calorifier and startup tests.
Figure 4. Schematic diagram of 30 kW calorifier and startup tests.
Materials 14 03016 g004
Figure 5. Optical images of heat pipes at 850 °C heating: (a) HP1, (b) HP2.
Figure 5. Optical images of heat pipes at 850 °C heating: (a) HP1, (b) HP2.
Materials 14 03016 g005
Figure 6. Startup results of heat pipes at 850 °C heating: (a) HP1, (b) HP2.
Figure 6. Startup results of heat pipes at 850 °C heating: (a) HP1, (b) HP2.
Materials 14 03016 g006
Figure 7. Startup results of heat pipes at 850 °C heating: (a) HP3, (b) HP4.
Figure 7. Startup results of heat pipes at 850 °C heating: (a) HP3, (b) HP4.
Materials 14 03016 g007
Figure 8. Startup properties of HP2–HP4 at 650–950 °C heating.
Figure 8. Startup properties of HP2–HP4 at 650–950 °C heating.
Materials 14 03016 g008
Figure 9. Optical images of tested HP1–HP4.
Figure 9. Optical images of tested HP1–HP4.
Materials 14 03016 g009
Figure 10. Thermal stresses (Mises) in sodium/Inconel 718 heat pipes at 850 °C heating: (a) HP3, (b) HP4.
Figure 10. Thermal stresses (Mises) in sodium/Inconel 718 heat pipes at 850 °C heating: (a) HP3, (b) HP4.
Materials 14 03016 g010
Figure 11. Mises stresses located in TC6 of sodium/Inconel 718 heat pipes.
Figure 11. Mises stresses located in TC6 of sodium/Inconel 718 heat pipes.
Materials 14 03016 g011
Figure 12. Axial deformation of HP3 and HP4 at 650–950 °C heating.
Figure 12. Axial deformation of HP3 and HP4 at 650–950 °C heating.
Materials 14 03016 g012
Figure 13. Elastic strains under a pressure of 5 MPa: (a) HP3, (b) HP4.
Figure 13. Elastic strains under a pressure of 5 MPa: (a) HP3, (b) HP4.
Materials 14 03016 g013
Table 1. Chemical compositions of Inconel 718.
Table 1. Chemical compositions of Inconel 718.
ElementNiFeCrCuMoNb
Weight Percent (%)50–55remainder17–21≤0.32.8–3.34.75–5.5
ElementCMnPSSiTi
Weight Percent (%)≤0.08≤0.35≤0.015≤0.015≤0.350.65–1.15
ElementAlCoB
Weight Percent (%)0.20–0.80≤1.00≤0.006
Table 2. Fabricated heat pipes with and without pentamode metamaterial reinforcement.
Table 2. Fabricated heat pipes with and without pentamode metamaterial reinforcement.
ModelsModel Weight
(g)
Charged Sodium
(g)
Charging Ratio
(%)
Density
(g/cm3)
Pentamode Metamaterials
HP1500.31682.04With
HP2495.01682.02Without
HP3498.220102.03With
HP4497.220102.03Without
Table 3. Parameters of thermal response simulation.
Table 3. Parameters of thermal response simulation.
ModelHP3/HP4Heating time600 s
Evaporator250 mmEmissivity0.9
Adiabatic50 mmFilm coefficient20 W/m−2 °C−1
Condenser200 mmGrid size≤5 × 10−3 m
Heating temperatures650 °C/750 °C/
850 °C/950 °C
Mesh typeHex dominant
Table 4. High temperature strength of Inconel 718 alloy [26].
Table 4. High temperature strength of Inconel 718 alloy [26].
Temperature (°C)Strength (MPa)Temperature (°C)Strength (MPa)
201200850299
6001040900180
650970950109
750710
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Hu, L.; Shi, K.; Luo, X.; Yu, J.; Ai, B.; Liu, C. Application of Additively Manufactured Pentamode Metamaterials in Sodium/Inconel 718 Heat Pipes. Materials 2021, 14, 3016. https://0-doi-org.brum.beds.ac.uk/10.3390/ma14113016

AMA Style

Hu L, Shi K, Luo X, Yu J, Ai B, Liu C. Application of Additively Manufactured Pentamode Metamaterials in Sodium/Inconel 718 Heat Pipes. Materials. 2021; 14(11):3016. https://0-doi-org.brum.beds.ac.uk/10.3390/ma14113016

Chicago/Turabian Style

Hu, Longfei, Ketian Shi, Xiaoguang Luo, Jijun Yu, Bangcheng Ai, and Chao Liu. 2021. "Application of Additively Manufactured Pentamode Metamaterials in Sodium/Inconel 718 Heat Pipes" Materials 14, no. 11: 3016. https://0-doi-org.brum.beds.ac.uk/10.3390/ma14113016

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop