No syntax errors found.                               CIF dictionary
Please wait while processing .... Interpreting this report
Datablock: 1_new
Bond precision: C-C = 0.0052 A Wavelength=1.54184
Cell: a=5.9496(1) b=12.4570(2) c=12.8656(1)
alpha=112.445(2) beta=95.687(2) gamma=103.040(2)
Temperature: 100 K
Calculated Reported
Volume 840.20(3) 840.20(3)
Space group P -1 P -1
Hall group -P 1 -P 1
Moiety formula C13 H20 N4 O, 2(Br), H2 O C13 H20 N4 O, 2(Br), H2 O
Sum formula C13 H22 Br2 N4 O2 C13 H22 Br2 N4 O2
Mr 426.15 426.15
Dx,g cm-3 1.684 1.684
Z 2 2
Mu (mm-1) 6.209 6.209
F000 428.0 428.0
F000' 426.15
h,k,lmax 7,15,16 7,15,16
Nref 3640 3443
Tmin,Tmax 0.083,0.830 0.126,1.000
Tmin' 0.013
Correction method= # Reported T Limits: Tmin=0.126 Tmax=1.000 AbsCorr = MULTI-SCAN
Data completeness= 0.946 Theta(max)= 78.980
R(reflections)= 0.0391( 3276) wR2(reflections)= 0.1146( 3443)
S = 1.126 Npar= 203

The following ALERTS were generated. Each ALERT has the format
       test-name_ALERT_alert-type_alert-level.
Click on the hyperlinks for more details of the test.

Alert level C PLAT417_ALERT_2_C Short Inter D-H..H-D H1D ..H26 . 2.14 Ang. x,y,z = 1_555 Check PLAT911_ALERT_3_C Missing FCF Refl Between Thmin & STh/L= 0.600 3 Report
Alert level G PLAT154_ALERT_1_G The s.u.'s on the Cell Angles are Equal ..(Note) 0.002 Degree PLAT398_ALERT_2_G Deviating C-O-C Angle From 120 for O22 103.6 Degree PLAT432_ALERT_2_G Short Inter X...Y Contact Br1 ..C21 3.31 Ang. 1-x,1-y,1-z = 2_666 Check PLAT912_ALERT_4_G Missing # of FCF Reflections Above STh/L= 0.600 195 Note PLAT978_ALERT_2_G Number C-C Bonds with Positive Residual Density. 3 Info
0 ALERT level A = Most likely a serious problem - resolve or explain 0 ALERT level B = A potentially serious problem, consider carefully 2 ALERT level C = Check. Ensure it is not caused by an omission or oversight 5 ALERT level G = General information/check it is not something unexpected 1 ALERT type 1 CIF construction/syntax error, inconsistent or missing data 4 ALERT type 2 Indicator that the structure model may be wrong or deficient 1 ALERT type 3 Indicator that the structure quality may be low 1 ALERT type 4 Improvement, methodology, query or suggestion 0 ALERT type 5 Informative message, check


It is advisable to attempt to resolve as many as possible of the alerts in all categories. Often the minor alerts point to easily fixed oversights, errors and omissions in your CIF or refinement strategy, so attention to these fine details can be worthwhile. In order to resolve some of the more serious problems it may be necessary to carry out additional measurements or structure refinements. However, the purpose of your study may justify the reported deviations and the more serious of these should normally be commented upon in the discussion or experimental section of a paper or in the "special_details" fields of the CIF. checkCIF was carefully designed to identify outliers and unusual parameters, but every test has its limitations and alerts that are not important in a particular case may appear. Conversely, the absence of alerts does not guarantee there are no aspects of the results needing attention. It is up to the individual to critically assess their own results and, if necessary, seek expert advice.

Publication of your CIF in IUCr journals

A basic structural check has been run on your CIF. These basic checks will be run on all CIFs submitted for publication in IUCr journals (Acta Crystallographica, Journal of Applied Crystallography, Journal of Synchrotron Radiation); however, if you intend to submit to Acta Crystallographica Section C or E or IUCrData, you should make sure that full publication checks are run on the final version of your CIF prior to submission.

Publication of your CIF in other journals

Please refer to the Notes for Authors of the relevant journal for any special instructions relating to CIF submission.


PLATON version of 13/07/2021; check.def file version of 13/07/2021
Datablock 1_new - ellipsoid plot


Download CIF editor (publCIF) from the IUCr
Download CIF editor (enCIFer) from the CCDC
Test a new CIF entry