No syntax errors found.                               CIF dictionary
Please wait while processing .... Interpreting this report
Datablock: 7_new
Bond precision: C-C = 0.0050 A Wavelength=1.54184
Cell: a=8.10852(3) b=7.06025(3) c=12.41650(7)
alpha=90 beta=92.2991(4) gamma=90
Temperature: 100 K
Calculated Reported
Volume 710.250(6) 710.250(6)
Space group P 21 P 21
Hall group P 2yb P 2yb
Moiety formula C13 H19 N4 O, Br C13 H19 N4 O 1+, Br 1-
Sum formula C13 H19 Br N4 O C13 H19 Br N4 O
Mr 327.22 327.22
Dx,g cm-3 1.530 1.530
Z 2 2
Mu (mm-1) 3.936 3.936
F000 336.0 336.0
F000' 335.40
h,k,lmax 10,8,15 10,8,15
Nref 3058[ 1658] 2988
Tmin,Tmax 0.765,0.899 0.216,1.000
Tmin' 0.039
Correction method= # Reported T Limits: Tmin=0.216 Tmax=1.000 AbsCorr = GAUSSIAN
Data completeness= 1.80/0.98 Theta(max)= 78.780
R(reflections)= 0.0333( 2969) wR2(reflections)= 0.0830( 2988)
S = 1.054 Npar= 177

The following ALERTS were generated. Each ALERT has the format
       test-name_ALERT_alert-type_alert-level.
Click on the hyperlinks for more details of the test.

Alert level B PLAT094_ALERT_2_B Ratio of Maximum / Minimum Residual Density .... 5.83 Report
Alert level C PLAT353_ALERT_3_C Long N-H (N0.87,N1.01A) N11 - H11 . 1.06 Ang. PLAT971_ALERT_2_C Check Calcd Resid. Dens. 0.80A From Br1 2.30 eA-3 PLAT971_ALERT_2_C Check Calcd Resid. Dens. 0.97A From Br1 1.74 eA-3 PLAT987_ALERT_1_C The Flack x is >> 0 - Do a BASF/TWIN Refinement Please Check
Alert level G PLAT013_ALERT_1_G N.O.K. _shelx_hkl_checksum Found in CIF ...... Please Check PLAT033_ALERT_4_G Flack x Value Deviates > 3.0 * sigma from Zero . 0.051 Note PLAT063_ALERT_4_G Crystal Size Possibly too Large for Beam Size .. 0.81 mm PLAT142_ALERT_4_G s.u. on b - Axis Small or Missing .............. 0.00003 Ang. PLAT143_ALERT_4_G s.u. on c - Axis Small or Missing .............. 0.00007 Ang. PLAT145_ALERT_4_G s.u. on beta Small or Missing .............. 0.0004 Degree PLAT398_ALERT_2_G Deviating C-O-C Angle From 120 for O22 102.9 Degree PLAT912_ALERT_4_G Missing # of FCF Reflections Above STh/L= 0.600 13 Note PLAT978_ALERT_2_G Number C-C Bonds with Positive Residual Density. 0 Info
0 ALERT level A = Most likely a serious problem - resolve or explain 1 ALERT level B = A potentially serious problem, consider carefully 4 ALERT level C = Check. Ensure it is not caused by an omission or oversight 9 ALERT level G = General information/check it is not something unexpected 2 ALERT type 1 CIF construction/syntax error, inconsistent or missing data 5 ALERT type 2 Indicator that the structure model may be wrong or deficient 1 ALERT type 3 Indicator that the structure quality may be low 6 ALERT type 4 Improvement, methodology, query or suggestion 0 ALERT type 5 Informative message, check


It is advisable to attempt to resolve as many as possible of the alerts in all categories. Often the minor alerts point to easily fixed oversights, errors and omissions in your CIF or refinement strategy, so attention to these fine details can be worthwhile. In order to resolve some of the more serious problems it may be necessary to carry out additional measurements or structure refinements. However, the purpose of your study may justify the reported deviations and the more serious of these should normally be commented upon in the discussion or experimental section of a paper or in the "special_details" fields of the CIF. checkCIF was carefully designed to identify outliers and unusual parameters, but every test has its limitations and alerts that are not important in a particular case may appear. Conversely, the absence of alerts does not guarantee there are no aspects of the results needing attention. It is up to the individual to critically assess their own results and, if necessary, seek expert advice.

Publication of your CIF in IUCr journals

A basic structural check has been run on your CIF. These basic checks will be run on all CIFs submitted for publication in IUCr journals (Acta Crystallographica, Journal of Applied Crystallography, Journal of Synchrotron Radiation); however, if you intend to submit to Acta Crystallographica Section C or E or IUCrData, you should make sure that full publication checks are run on the final version of your CIF prior to submission.

Publication of your CIF in other journals

Please refer to the Notes for Authors of the relevant journal for any special instructions relating to CIF submission.


PLATON version of 13/07/2021; check.def file version of 13/07/2021
Datablock 7_new - ellipsoid plot


Download CIF editor (publCIF) from the IUCr
Download CIF editor (enCIFer) from the CCDC
Test a new CIF entry