Personalized Evaporative Cooler to Reduce Energy Consumption and Improve Thermal Comfort in Free-Running Spaces

Research Group in Thermal Engineering, Department of Energy and Fluidmechanics, School of Engineering, Universidad de Valladolid, Paseo del Cauce No.59, 47011 Valladolid, Spain
*
Author to whom correspondence should be addressed.
Sustainability 2019, 11(22), 6451; https://0-doi-org.brum.beds.ac.uk/10.3390/su11226451
Received: 18 October 2019 / Revised: 5 November 2019 / Accepted: 12 November 2019 / Published: 16 November 2019
(This article belongs to the Special Issue The Application of Renewable Energy in Sustainable Architecture)
The need to reduce energy consumption in buildings is imperative, but we must maintain individual thermal comfort of the occupants to ensure their well-being and productivity. Personal conditioning systems (PCS) have been suggested as a strategy to achieve both energy efficiency and thermal comfort, as they are considered to be low-energy consumers, allow increasing set-point temperatures, and give occupants the chance to control their own personal environment. While most warm-environment PCS are based on air-movement devices, the potential of using desk direct evaporative coolers (dDEC) has been scarcely explored. This work presents the results of the characterization of a dDEC and its potential for improving the indoor temperature and thermal comfort in a free-running office space. The study proposes adapted corrective power (CPa) and cooling fan efficiency for evaporative systems (CFEe) indexes. Results show that the dDEC achieves thermal comfort with a local effect, and it is recommended to be positioned directly on the desk surface, orientated to the occupant, and at a certain distance. Under these conditions, the CPa reaches −2.8 °C, involving better CFEe than the desk fans studied in the literature. Speed has little effect on the local air conditions, though it does improve the perception of thermal comfort. The relative humidity of the air does not exceed the recommendable limits, but renovation of the indoor air enables better conditions. View Full-Text
Keywords: desk direct evaporative cooler; personalized cooling system; adapted corrective power; predicted mean vote; free-running buildings desk direct evaporative cooler; personalized cooling system; adapted corrective power; predicted mean vote; free-running buildings
Show Figures

Figure 1

MDPI and ACS Style

Tejero-González, A.; Esquivias, P.M. Personalized Evaporative Cooler to Reduce Energy Consumption and Improve Thermal Comfort in Free-Running Spaces. Sustainability 2019, 11, 6451. https://0-doi-org.brum.beds.ac.uk/10.3390/su11226451

AMA Style

Tejero-González A, Esquivias PM. Personalized Evaporative Cooler to Reduce Energy Consumption and Improve Thermal Comfort in Free-Running Spaces. Sustainability. 2019; 11(22):6451. https://0-doi-org.brum.beds.ac.uk/10.3390/su11226451

Chicago/Turabian Style

Tejero-González, Ana, and Paula M. Esquivias. 2019. "Personalized Evaporative Cooler to Reduce Energy Consumption and Improve Thermal Comfort in Free-Running Spaces" Sustainability 11, no. 22: 6451. https://0-doi-org.brum.beds.ac.uk/10.3390/su11226451

Find Other Styles
Note that from the first issue of 2016, MDPI journals use article numbers instead of page numbers. See further details here.

Article Access Map by Country/Region

1
Back to TopTop