Article

Kinetics of Microcystin-LR Removal in a Real Lake Water by UV/H2O2 Treatment and Analysis of Specific Energy Consumption

by
Sabrina Sorlini
1,*,
Carlo Collivignarelli
1,
Marco Carnevale Miino
2,
Francesca Maria Caccamo
2 and
Maria Cristina Collivignarelli
2,3
1
Department of Civil, Environmental, Architectural Engineering and Mathematics, University of Brescia, 25123 Brescia, Italy
2
Department of Civil Engineering and Architecture, University of Pavia, 27100 Pavia, Italy
3
Interdepartmental Centre for Water Research, University of Pavia, 27100 Pavia, Italy
*
Author to whom correspondence should be addressed.
Submission received: 24 November 2020 / Revised: 16 December 2020 / Accepted: 18 December 2020 / Published: 21 December 2020
(This article belongs to the Special Issue Removal of Cyanobacteria and Cyanotoxins in Waters)

Abstract

:
The hepatotoxin microcystin-LR (MC-LR) represents one of the most toxic cyanotoxins for human health. Considering its harmful effect, the World Health Organization recommended a limit in drinking water (DW) of 1 µg L−1. Due to the ineffectiveness of conventional treatments present in DW treatment plants against MC-LR, advanced oxidation processes (AOPs) are gaining interest due to the high redox potential of the OH radicals. In this work UV/H2O2 was applied to a real lake water to remove MC-LR. The kinetics of the UV/H2O2 were compared with those of UV and H2O2 showing the following result: UV/H2O2 > UV > H2O2. Within the range of H2O2 tested (0–0.9 mM), the results showed that H2O2 concentration and the removal kinetics followed an increasing quadratic relation. By increasing the initial concentration of H2O2, the consumption of oxidant also increased but, in terms of MC-LR degraded for H2O2 dosed, the removal efficiency decreased. As the initial MC-LR initial concentration increased, the removal kinetics increased up to a limit concentration (80 µg L−1) in which the presence of high amounts of the toxin slowed down the process. Operating with UV fluence lower than 950 mJ cm−2, UV alone minimized the specific energy consumption required. UV/H2O2 (0.3 mM) and UV/H2O2 (0.9 mM) were the most advantageous combination when operating with UV fluence of 950–1400 mJ cm−2 and higher than 1400 mJ cm−2, respectively.
Key Contribution: UV/H2O2 showed higher kinetics in free MC-LR removal and allowed it to minimize the specific energy consumption operating with UV fluence higher than 950 mJ cm−2.

Graphical Abstract

1. Introduction

Microcystin-LR (MC-LR) is a hepatotoxin produced by cyanobacteria such as Microcystis aeruginosa, Planktothrix, Nostoc and Anabaea and represents one of the most common and most toxic cyanotoxins for human health [1,2,3]. Cyanobacteria growth is enhanced in the presence of particular conditions such as mild temperature of water (25–35 °C), low flow rates, high concentration of nitrogen and phosphorous [4,5]. Therefore, lakes in areas with a temperate and warm climate represent a perfect habitat for their growth.
Cyanotoxins can interact and alter different parts of human metabolism with consequent effects on health of varying severity. For example, all cyanobacteria genera can produced cyanotoxins belonging to the group of Lipopolysaccharides, which have only a potential irritating effect on the tissues they have come into contact with [6]. On the other hand, the microcystins and nodularins, belonging to the group of cyclic peptides, have the liver as their main target of action being able to cross cell membranes mainly through the bile acid transporter [2,6]. Several studies highlighted the effects on liver tissue in humans exposed chronically to MC-LR [7,8,9].
The effect of microcystins was also studied by Zhou et al. [10]. They identified that the incidence rate of colorectal cancer was significantly higher in the population who drank water with high concentration of microcystins (e.g., river water) than those who drank tap water [10]. This harmful effect on intestinal cells was also confirmed by subsequent studies [11]. Alosman et al. [12] also pointed out that, aside the liver, MC-LR can cause also cardiogenic complications even if standardized animal models would be needed before the cardiotoxicity of the toxin can be defined with certainty.
The ingestion/inhalation of contaminated water in recreation (e.g., watersports) and, above all, the consumption of contaminated drinking water (DW) represent the main routes of exposure of humans to the toxin [2,6]. The effects due to secondary exposure, such as those due to the presence of MC-LR in plants and vegetables irrigated with water rich in toxins, are also being studied and quantified [13,14].
Considering the harmful effect of MC-LR revealed in literature results, the International Agency for Research on Cancer (IARC) classified this cyanotoxin as possible carcinogenic to humans (Group 2B) [6]. Based on this classification, the World Health Organization (WHO) included the MC-LR within the parameters to be monitored in DW, recommending a temporary limit of 1 µg L−1 for total MC-LR (free plus cell-bound) [2]. The European Union implemented this recommendation by including the MC-LR in the revision of the Drinking Water Directive in 2018, providing for a limit of 1 µg L−1 [15]. At the current date (15 December 2020) the proposed revision of the directive has not yet been approved so there is currently no unitary legislation at the European Union level about the presence of this toxin in DW.
However, several EU countries where the presence of cyanotoxins within surface water bodies is more widespread have already legislated on the matter providing national limits. For example, in 2012, Italy introduced a limit of 1 µg L−1 as equivalent MC-LR referring to the sum of the concentrations of the different microcystins congeners present in DW [16]. In France, in 2001 a decree set the limit of 1 µg L−1 for MC-LR in DW [17]. Instead, in 2007, this limit was referred to the sum of the microcystins quantified in the sample [17,18].
Even some non-European countries promoted laws or guidelines in order to minimize the risks for human health related to cyanobacteria and cyanotoxins in DW. For example, Canada established legislative limits for DW, with a seasonal maximum acceptable concentration of 1.5 µg L−1 for total microcystins [19], and provided a draft of guidelines for recreational water quality a maximum acceptable concentration of 10 µg L−1 for total microcystins [20]. Australia has provided non-mandatory guidelines suggesting that the concentration of total microcystins in DW should not exceed 1.3 µg L−1 expressed as microcystin-LR toxicity equivalents [21].
There are two possible approaches to address the problem of the presence of MC-LR in waters: (i) remove the cyanobacteria that produce them or (ii) directly eliminate the free toxin [1]. The conventional treatments present in a drinking water treatment plant (DWTP; e.g., coagulation, flocculation, sedimentation and filtration) allow one to implement the first of the two approaches [22,23,24,25]. However, these treatments are not able to remove the MC-LR already secreted by cyanobacteria and present in the water in dissolved form [26]. On the contrary, adsorption on AC is confirmed to be a viable solution for the removal of low molecular weight substances such as cyanotoxins in general and specifically MC-LR [27,28,29].
Recently, even advanced oxidation processes (AOPs) are gaining interest in the removal of MC-LR due to the high redox potential of the hydroxyl radicals (OH) or sulfate radicals (SO4•−) developed in the process, which allows one to overcome some limitations given by the limited oxidizing power of other oxidizing agents towards MC-LR, such as H2O2 [30,31].
UV/H2O2 represents one of the AOPs. The main advantages are given by the absence of chemical sludge production (as opposed for instance to the Fenton process [32]), by the absence of toxic DBPs formation (unlike processes that involve chlorine and ozone [33,34,35,36]), and by the great ease of finding the oxidants used (as opposed to processes involving the use of nanostructured metals [37]).
In literature, several examples of application of this process for the removal of MC-LR are reported. UV lamps are used that emit at 254 nm of wavelength [38], close to the wavelength of maximum absorption of the MC-LR (235–238 nm [38,39]) or at 268 nm of wavelength [40]. However, most of the experiments involved the use of synthetic waters, thus only partially evaluating the combined effect of the presence of scavenger substances in the process such as the carbonates. On the contrary, this paper aims to evaluate the effectiveness of UV/H2O2 on a real lake water studying kinetics of free MC-LR removal to understand the influence of UV fluence, H2O2 dosage and initial MC-LR concentration on the process effectiveness. Moreover, the total specific energy consumption of UV/H2O2 for MC-LR removal has been evaluated and compared with UV alone to find the optimal operational conditions.

2. Results and Discussion

2.1. Effect of the Oxidant

The effectiveness of the H2O2, UV and UV/H2O2 processes for MC-LR removal was investigated. Figure 1 shows the degradation of MC-LR as a function of the UV fluence using different oxidants.
H2O2 alone did not allow us to remove the toxin even with high contact time. This result is confirmed by Liu et al. [40] who observed an almost absent removal of dissolved MC-LR (0.1 µM) using H2O2 (0.1 mM) at pH nearly 7. On the contrary, the photolysis treatment with UV-C was found to be weakly effective in removing MC-LR (about 50%), with UV fluence equal to or lower than 1000 mJ cm−2. The toxin removal enhanced to 80% using the maximum UV fluence tested (2000 mJ cm−2).
The UV/H2O2 combination ensured removal yields higher than 90% with UV fluence equal to 2000 mJ cm−2 and H2O2 concentration of 0.9 mM. This result can be attributed to the production of OH radicals capable of almost completely oxidizing the MC-LR due to their high redox potential [41]. He et al. [38] confirmed the higher effectiveness of UV/H2O2 with respect with UV alone, obtaining more than 90% of MC-LR removal after 80 mJ cm−2 of fluence dose (H2O2: 1.76 mM) compared to around 20% obtained with UV alone. On the contrary to He et al. study [38], in the present work, a lower MC-LR removal was obtained using the same fluence dose, probably due to the higher initial pH that may have favored the scavenging effect on OH production [42].

2.2. Influence of H2O2 Dosage

The influence H2O2 dosage on the kinetics of MC-LR removal was studied. As shown in Figure A1 in the Appendix A, all results were well fitted by applying the first-order kinetics model to calculate the MC-LR removal kinetic constants (Figure 2a and Table A1 in Appendix A). As already shown in Figure 1, the H2O2 dosage generally allowed a better removal yield of the MC-LR. However, this result appeared to be dependent on the concentration of H2O2 dosed in the reaction. In fact, the UV/H2O2 combination ensured an efficacy in removing the toxin directly proportional to the quantity of chemical oxidant dosed. The half-life time (HLT) of the MC-LR was reduced from 64.2 (UV alone) to 57.8 min (−10%), 52.5 min (−18%) and 41.3 min (−36%) in the case of UV/H2O2 (0.15 mM), UV/H2O2 (0.30 mM) and UV/H2O2 (0.90 mM), respectively.
This relation was even more evident by comparing the apparent constant rate of the process (expressed as kfluence) as a function of the H2O2 dosage. In Figure 2b it can be observed that, for low dosages of H2O2 (≤0.3 mM), the increase of removal kinetics can be perfectly linearly fitted (R2 = 1). The increase in the kinetics of MC-LR removal was attributable to the increase in OH production due to the initial higher concentration of H2O2 as already seen for anatoxin-a removal [43]. This result is in agreement with He et al. [38] who studied MC-LR removal from synthetic DW using UV/H2O2. They highlighted that, with initial H2O2 concentrations below 1 mM, the MC-LR degradation rate constant seemed to increase proportionally with the chemical oxidant concentration following a linear relation [38].
However, considering also a higher H2O2 dosages (0.9 mM), the best fitting has been obtained with a quadratic function (R2 > 0.99). In fact, when the H2O2 concentration reached high level (1 mM for [38] or more than 3 mM for [42]), the production of OH could be inhibited due to scavenging effect and the removal of MC-LR could remain almost constant or decrease [38,42].
Compared to results obtained by He et al. [38] and Loaiza-González [44], in the present work, lower removal kinetics were obtained using the same concentration of oxidizing agent. This could be related with the presence in the real lake water of higher concentrations of carbonates (Table A3 in Appendix A), which have a high scavenger effect, unlike chlorides and sulphates [38].
Furthermore, the amount of oxidant consumed in the UV/H2O2 process and the H2O2 efficiency in removing MC-LR were evaluated. By increasing the initial concentration of H2O2, the consumption of oxidant also increased (Figure 3a). This can explain the kinetics detailed in Figure 2b: for constant UV fluence, higher H2O2 consumption means higher OH production and therefore higher MC-LR removal. However, as the H2O2 consumed increased, the removal efficiency of the MC-LR decreased, in terms of MC-LR degraded for H2O2 dosed (Figure 3b). This result was also observed by Penru et al. [45] in the application of the UV/H2O2 for the removal of organic matter and it was attributed to the scavenging effect of hydroxyl radicals that can limit the oxidative power of the process.

2.3. Influence of Initial MC-LR Concentration

Investigations on UV/H2O2 effectiveness were repeated keeping the H2O2 dosage constant and varying the initial concentration of MC-LR. The tests were conducted on real water with the addition of MC-LR to obtain a concentration of 0.8 µg L−1, 50 µg L−1 and 100 µg L−1. Increasing the initial MC-LR concentration from 0.8 to 50 µg L−1, the removal yields enhanced from 25% to 87.5% (Figure 4). Further increasing the initial MC-LR concentration to 100 µg L−1 did not result in an enhancement in toxin removal yields.
As shown in Figure A2 in Appendix A, all results were well fitted by applying the first-order kinetics model to calculate the MC-LR removal kinetic constants (Table A2 in Appendix A). By increasing the initial concentration of toxin from 0.8 to 50 µg L−1, HLT decreased by about 82% (from 288.8 to 52.5 min). The further increase in the initial MC-LR concentration to 100 µg L−1 did not lead to a change in the removal kinetics.
Comparing the apparent rate constant of the process as a function of the initial toxin concentration (Figure 5), the experimental points were well fitted by a second degree polynomial function that predicted an increase of MC-LR degradation kinetics when the initial concentration moved from 0 to 80 µg L−1. On the contrary, as the initial MC-LR increased after 80 µg L−1, a lowering of the kinetics of removal was detected. This result was confirmed in the literature by several studies where the lower kinetics, obtained with high MC-LR concentration, are linked to the increase of the internal optical density, which decrease the fraction of light absorbed by H2O2 limiting OH production [38,40,42]. On the contrary, with initial MC-LR concentration lower than 80 µg L−1, the obscuration of UV rays can be considered absent.

2.4. Energy Consumption

The specific energy consumption required to remove MC-LR by one order of magnitude (EEO) was assessed considering both the consumption given by the presence of UV (EEO, UV) and the use of H2O2 (EEO, oxidant). As shown in Figure A3 in Appendix A, electrical energy per order (EEO) was reported as a function of H2O2 dosage with tested UV fluence.
The results show that the total specific energy consumption (EEO, total) followed two different behaviors depending on the UV fluence considered and the H2O2 dosed (Figure A4 in the Appendix A). As the dosage of H2O2 increased, EEO, total decreased with high UV fluences (1000 mJ cm−2, 1500 mJ cm−2 and 2000 mJ cm−2) while, in the presence of lower UV fluences (50 mJ cm−2, 300 mJ cm−2 and 600 mJ cm−2), EEO, total increased even significantly as the concentration of the chemical oxidant dosed increased (Figure A4 in Appendix A).
In fact, significant H2O2 dosages in the presence of low UV radiation did not produce a significant increase in the effectiveness in removing MC-LR. On the contrary, by keeping the H2O2 dosage constant and increasing the fluence dose, the removal of MC-LR was more effective due to a greater production of OH radicals. Therefore, the specific energy consumption in relation to the MC-LR removed was lower.
By analyzing the behavior of EEO, total as a function of UV fluence (Figure 6), the optimal dosage of H2O2 that minimized the total specific energy consumption related with MC-LR removed was identified. Operating at low fluence rates (lower than 950 mJ cm−2), UV alone allowed it to minimize the EEO, total. Operating between 950 and 1400 mJ cm−2, UV/H2O2 (0.3 µg L−1) combination minimized specific consumption while, for UV fluence higher than 1400 mJ cm−2, the combination UV/H2O2 (0.9 µg L−1) was the most advantageous due to higher MC-LR removal.
However, EEO values strongly depend on the removal yields of the toxin and therefore on the production of OH radicals. In addition to the concentration of oxidants used, the production of hydroxyl radicals also depends on many other aspects including the hydrodynamics of the reactor and its configuration [46]. Therefore, a direct comparison with other research is difficult to make. However, although there are not many literature data on EEO related to the removal of MC-LR and most of those reported do not evaluate the energetic consumption related to the use of oxidants, the values obtained are of the same order of magnitude as those reported by Schneider and Bláha (2020) [47].

3. Conclusions

The kinetics of the UV/H2O2 process was compared with those of UV and H2O2 showing the following result: UV/H2O2 > UV > H2O2. The UV/H2O2 combination allowed the removal of up to 93% of MC-LR (MC-LR0: 50 µg L−1; H2O2: 0.9 mM; UV fluence: 2000 mJ cm−2 and fluence rate: 0.2 mW cm−2). Within the range of H2O2 concentrations tested (0–0.9 mM), the results showed that H2O2 concentration and the removal kinetics followed a quadratic relation. By increasing the initial concentration of H2O2, the consumption of oxidant also increased but, in terms of MC-LR degraded for H2O2 dosed, the removal efficiency decreased. The initial concentration of MC-LR can significantly influence the kinetics of removal. The results showed that as the MC-LR0 increased, the removal kinetics increased, up to a limit concentration (80 µg L−1) in which the presence of high amounts of the toxin slowed down the process. About the specific energy consumption, UV alone minimized the specific energy consumption required when operating with UV fluence lower than 950 mJ cm−2. Operating between 950 and 1400 mJ cm−2, UV/H2O2 (0.3 mM) was the most advantageous combination while for UV fluence higher than 1400 mJ cm−2, the use of UV/H2O2 (0.9 mM) was the solution that involved lower energy consumption in relation to the quantity of MC-LR removed.

4. Materials and Methods

4.1. Water Preparation

In this study, powdered MC-LR (type ALX–350–012–C500; purity ≥ 95%; Enzo Life Sciences Farmingdale, NY, USA) was stored at −20 °C and used to prepare a 50 mg L−1 solution by adding 10 mL ethanol (≥99.8%) to 0.5 mg powdered MC-LR.
In order to better simulate conditions of treatment of a real DW, raw water was collected from Iseo Lake, in Peschiera Maraglio of Monteisola, in Northern Italy (province of Brescia, Lombardy) at 40 m depth and 40 m from the shore. Characteristics of raw water are reported in Table A2 in Appendix A. To separate dissolved MC-LR from cells, lake water samples were filtered using a 0.45 μm (pore size) glass fiber filter [48,49] and the permeate (MC-LR = 0.1 µg L−1) was spiked with the MC-LR solution to obtain toxin concentrations of 0.8 µg L−1, 50 µg L−1 and 100 µg L−1. Spiked waters were stored at 5 °C.

4.2. The Lab-Scale System

The batch system used for experimental tests was composed as described in Figure 7. A low-pressure mercury UV lamp, which emits at 254 nm of wavelength, was used. A black lampshade avoided the dispersion of the light beams to the sides and allowed it to concentrate the radiation on the reactor. The intensity of the irradiation given by the UV-C rays incident on the reactor was 0.2 mW cm−2. A 50 mL Petri dish (diameter 5.45 cm, height 3.525 cm and thickness 0.25 cm), without lid, was used as a reactor. Inside the reactor, the water (depth 2.60 cm) was kept in constant stirring due to a magnetic stirring apparatus.

4.3. Experimental Set-Up and Analytical Methods

This study was carried out testing the following processes:
  • H2O2 alone;
  • UV alone;
  • UV/H2O2 combination.
Tests were conducted at room temperature (22 ± 2 °C) and aimed to study the kinetics of MC-LR removal and investigate the effects of H2O2 dosage and initial MC-LR concentration.
Hydrogen peroxide (30%, w/v) was purchased from Carlo Erba Reagents S.r.l (Cornaredo, Lombardy, Italy) and, during tests, the residual concentration was measured using the triiodide method [50].
Before each experiment, to ensure a stable radiation, the UV lamps were allowed to warm up for 15 min. Fluence rate was measured with iodide/iodate actinometry method [51] and was equal to 0.2 mW cm−2.
pH value was monitored by means a portable multiparameter instrument (WTW 3410 SET4, Xylem Analytics Germany Sales GmbH, Weilheim, Germany).
After each fluence interval, samples were collected and catalase from Micrococcus lysodeikticus solution (Sigma Aldrich, St. Louis, MO, USA) was used to quench H2O2 reaction in samples before analysis according to Liu et al. [52]. The residual MC-LR concentration was measured with enzyme-linked immunosorbent assay (ELISA) kit, purchased from Eurofins Abraxis (Warminster, PA, USA). LOD and LOQ were equal to 0.1 µg L−1 and 5.0 µg L−1, respectively. The treated samples were diluted with Milli-Q water in order to obtain measurable values.

4.4. MC-LR Degradation

The results were elaborated according to a pseudo-first order kinetic as reported in Equation (1) [38]:
C = C0 × e−kfluence × F
where C0 represents the initial concentration of MC-LR and C is the current i-th value. kfluence represents the apparent rate constant of the process (cm2 mJ−1) and F is the UV fluence (mJ cm−2). ktime (min−1) was calculated considering the fluence rate of the system (0.2 mW cm−2), and consequently half-life time (HLT) of MC-LR during treatments was found using the following equation [14]:
HLT = ln(2) × ktime−1

4.5. Hydrogen Peroxide Consumption

Considering the amount of H2O2 consumed and the MC-LR removed, the H2O2 efficiency (mg mmol−1) was calculated according to Equation (3) [45]:
H2O2 efficiency = MC-LRremoved × H2O2consumed−1

4.6. Energy Consumption

When the concentration of the contaminant is very low, the amount of electric energy required to reduce the contaminant concentration by one order of magnitude can be considered independent of the initial concentration [46,53]. The water depth and the distance between the lamp and the water surface could affect the order of magnitude of the removal [46]. Although the lamp was not submerged into the reactor, in this work these two effects were neglected considering: (i) the low level of water inside the reactor and (ii) the presence of the black lampshade that avoided the dispersion of UV rays conveying them onto the reactor. Therefore, the energy consumption of the UV system was evaluated following the kinetic model of the electrical energy per order (EEO) according to Equation (4) [46,54,55]:
EEO,UV = (P × t × 103) × (V × log10(C0 C−1))−1
where P is the nominal power (kW) of the system, t (h) is the processing time and V (L) is the volume of water. The nominal power (P) was assumed equal to the energy input to the system, considering a fluence rate of 0.2 mW cm−2 and assuming a UV-C production yield of the lamp equal to 35%.
In view of the application on a larger scale, it is important to know not only the energy consumption necessary to produce UV-C but also the energy consumption due to the dosage of the oxidizing reagent (H2O2). In this work also, the chemical energy consumption associated to H2O2 was evaluated according to Equation (5) [56]:
EEO,oxidant = (CH2O2 × CF) × (log10(C0 C−1))−1
where CH2O2 is the concentration of H2O2 (g m−3) and CF is a conversion factor equal to 6.67 × 10−3 kWh g−1 [56,57,58]. Therefore, total energy consumption can be calculated as reported in Equation (6):
EEO,total = EEO,UV + EEO,oxidant

Author Contributions

Conceptualization, S.S., M.C.M. and M.C.C.; Data curation, S.S., C.C. and M.C.M.; Investigation, S.S. and C.C.; Methodology, S.S., C.C. and M.C.C.; Resources, S.S. and C.C.; Supervision, S.S., C.C. and M.C.C.; Validation, S.S., C.C. and M.C.C.; Visualization, F.M.C.; Writing—original draft, S.S., M.C.M., F.M.C. and M.C.C.; Writing—review and editing, S.S., M.C.M. and M.C.C. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Acknowledgments

The authors wish to thank Trojan Technologies for providing the lab-scale system used in the experimentation and Acque Ovest Bresciano 2 S.r.l. (Acque Bresciane S.r.l.) for having made their laboratories available for the analysis of MC-LR concentration. The Author thank also Eng. Francesca Gialdini and Eng. Michela Biasibetti for their technical support to the research.

Conflicts of Interest

The authors declare no conflict of interest.

Abbreviations

AOPsAdvanced oxidation processes
DWDrinking water
DWTPDrinking water treatment plant
HLTHalf-life time
IARCInternational Agency for Research on Cancer
LODLimit of detection
LOQLimit of quantification
MC-LRMicrocystin-LR
UVUltraviolet
WHOWorld Health Organization

Appendix A

Figure A1. Normalized MC-LR concentration decay following a first-order kinetics model in UV alone and UV/H2O2 processes. The colored lines represented curve fitting. Conditions: [MC-LR]0 = 50 µg L−1; pH = 7.5 and fluence rate = 0.2 mW cm−2.
Figure A1. Normalized MC-LR concentration decay following a first-order kinetics model in UV alone and UV/H2O2 processes. The colored lines represented curve fitting. Conditions: [MC-LR]0 = 50 µg L−1; pH = 7.5 and fluence rate = 0.2 mW cm−2.
Toxins 12 00810 g0a1
Figure A2. Normalized MC-LR concentration decay following a first-order kinetics model in UV/H2O2 processes with different initial MC-LR concentration. The colored lines represented curve fitting. Conditions: H2O2 dosage = 0.3 mM; pH = 7.5 and fluence rate = 0.2 mW cm−2.
Figure A2. Normalized MC-LR concentration decay following a first-order kinetics model in UV/H2O2 processes with different initial MC-LR concentration. The colored lines represented curve fitting. Conditions: H2O2 dosage = 0.3 mM; pH = 7.5 and fluence rate = 0.2 mW cm−2.
Toxins 12 00810 g0a2
Figure A3. Electrical energy per order (EEO) as function of H2O2 dosage with different UV fluence. Conditions: MC-LR0 = 50 µg L−1; pH = 7.5 and fluence rate = 0.2 mW cm−2.
Figure A3. Electrical energy per order (EEO) as function of H2O2 dosage with different UV fluence. Conditions: MC-LR0 = 50 µg L−1; pH = 7.5 and fluence rate = 0.2 mW cm−2.
Toxins 12 00810 g0a3
Figure A4. Total electrical energy per order (EEO), by different UV fluences, as a function of H2O2 dosage.
Figure A4. Total electrical energy per order (EEO), by different UV fluences, as a function of H2O2 dosage.
Toxins 12 00810 g0a4
Table A1. Kinetic constants and half-life times (HLT) of MC-LR during degradation by UV and UV/H2O2 using a first-order kinetics model. Conditions: MC-LR0 = 50 µg L−1; pH = 7.5; fluence rate = 0.2 mW cm−2 and N = number of total data.
Table A1. Kinetic constants and half-life times (HLT) of MC-LR during degradation by UV and UV/H2O2 using a first-order kinetics model. Conditions: MC-LR0 = 50 µg L−1; pH = 7.5; fluence rate = 0.2 mW cm−2 and N = number of total data.
UVUV/H2O2
(0.15 mM)
UV/H2O2
(0.30 mM)
UV/H2O2
(0.90 mM)
R2 (-)0.9770.9740.9850.963
kfluence (cm2 mJ)0.00090.0010.00110.0014
ktime (min−1)0.01080.01200.01320.0168
HLT (min)64.257.852.541.3
n (-)127167
Table A2. Kinetic constants and half-life times (HLT) of MC-LR during degradation by UV/H2O2, with different initial MC-LR concentration, using a first-order kinetics model. Conditions: H2O2 dosage = 0.3 mM; pH = 7.5; fluence rate = 0.2 mW cm−2 and N = number of total data.
Table A2. Kinetic constants and half-life times (HLT) of MC-LR during degradation by UV/H2O2, with different initial MC-LR concentration, using a first-order kinetics model. Conditions: H2O2 dosage = 0.3 mM; pH = 7.5; fluence rate = 0.2 mW cm−2 and N = number of total data.
UV/H2O2
(0.8 µg L−1)
UV/H2O2
(50 µg L−1)
UV/H2O2
(100 µg L−1)
R2 (-)0.9400.9900.956
kfluence (cm2 mJ)0.00020.00110.0011
ktime (min−1)0.00240.01320.0132
HLT (min)288.852.552.5
n (-)3165
Table A3. Characteristics of the raw water before filtration.
Table A3. Characteristics of the raw water before filtration.
ParameterUnit of MeasureAverage Value
pH-7.5
Dissolved oxygenmg L−19.5–9.7
TurbidityNTU2–3
Absorbance UV at 254 nm1 cm−10.010–0.020
Suspended solidsmg L−10–1
Conductivity at 20 °CµS cm−1260–270
Alkalinitymg HCO3 L−1120–130
Bacteria colony count at 22 °CCFU mL−180–90
Total coliforms at 37 °CMPN 100 mL−165–75
EnterococcusMPN 100 mL−12–4
Escherichia coliMPN 100 mL−18–10
Pseudomonas aeruginosaCFU 250 mL−12–4
Clostridium perfringensCFU 100 mL−11–3
Cyanobacterial algaecells L−11,700,000–2,000,000
Total algaecells L−13,500,000–3,600,000

References

  1. Sorlini, S.; Collivignarelli, M.C.; Carnevale Miino, M. Technologies for the control of emerging contaminants in drinking water treatment plants. Environ. Eng. Manag. J. 2019, 18, 2203–2216. [Google Scholar]
  2. WHO. WHO Guidelines for Drinking-Water Quality: Fourth Edition Incorporating the First Addendum; World Health Organization: Geneve, Switzerland, 2017; pp. 1–631. [Google Scholar]
  3. Leblanc, P.; Merkley, N.; Thomas, K.; Lewis, N.I.; Békri, K.; Renaud, S.L.; Pick, F.R.; McCarron, P.; Miles, C.O.; Quilliam, M.A. Isolation and Characterization of [D-Leu1]microcystin-LY from Microcystis aeruginosa CPCC-464. Toxins 2020, 12, 77. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  4. Sorlini, S.; Collivignarelli, M.C.; Abba, A. Control Measures for Cyanobacteria and Cyanotoxins in Drinking Water. Environ. Eng. Manag. J. 2018, 17, 2455–2463. [Google Scholar] [CrossRef]
  5. Kim, S.; KimiD, S.; Mehrotra, R.; Sharma, A. Predicting cyanobacteria occurrence using climatological and environmental controls. Water Res. 2020, 175, 115639. [Google Scholar] [CrossRef] [PubMed]
  6. IARC. IARC Monographs on the Evaluation of Carcinogenic Risks to Humans|Ingested Nitrate and Nitrite, and Cyanobacterial Peptide Toxins; International Agency for Research on Cancer: Lyon, France, 2010; Volume 94, pp. 1–464. [Google Scholar]
  7. Greer, B.; Meneely, J.P.; Elliott, C.T. Uptake and accumulation of Microcystin-LR based on exposure through drinking water: An animal model assessing the human health risk. Sci. Rep. 2018, 8, 1–10. [Google Scholar] [CrossRef] [Green Version]
  8. Yang, S.; Chen, L.; Wen, C.; Zhang, X.; Feng, X.; Yang, F. MicroRNA expression profiling involved in MC-LR-induced hepatotoxicity using high-throughput sequencing analysis. J. Toxicol. Environ. Heal. Part A 2018, 81, 89–97. [Google Scholar] [CrossRef]
  9. Sun, Y.T.; Zheng, Q.; Huang, P.; Guo, Z.; Xu, L.H. Microcystin-lr induces protein phosphatase 2a alteration in a human liver cell line. Environ. Toxicol. 2013, 29, 1236–1244. [Google Scholar] [CrossRef]
  10. Zhou, L.; Yu, H.; Chen, K. Relationship between microcystin in drinking water and colorectal cancer. Biomed. Environ. Sci. 2002, 15, 166–171. [Google Scholar]
  11. Wen, C.; Zheng, S.; Yang, Y.; Li, X.; Chen, J.; Wang, X.; Feng, X.; Yang, F. Effects of microcystins-LR on genotoxic responses in human intestinal epithelial cells (NCM460). J. Toxicol. Environ. Heal. Part A 2019, 82, 1113–1119. [Google Scholar] [CrossRef]
  12. Yang, F.; Cao, L.; Massey, I.Y.; Yang, F. The lethal effects and determinants of microcystin-LR on heart: A mini review. Toxin Rev. 2020, 1–10. [Google Scholar] [CrossRef]
  13. Xiang, L.; Li, Y.W.; Wang, Z.R.; Liu, B.L.; Zhao, H.M.; Li, H.; Cai, Q.Y.; Mo, C.H.; Li, Q. Bioaccumulation and Phytotoxicity and Human Health Risk from Microcystin-LR under Various Treatments: A Pot Study. Toxins 2020, 12, 523. [Google Scholar] [CrossRef] [PubMed]
  14. Araújo, M.K.C.; Chia, M.A.; Arruda-Neto, J.D.D.T.; Tornisielo, V.L.; Vilca, F.Z.; Bittencourt-Oliveira, M.D.C. Microcystin-LR bioaccumulation and depuration kinetics in lettuce and arugula: Human health risk assessment. Sci. Total Environ. 2016, 566, 1379–1386. [Google Scholar] [CrossRef] [PubMed]
  15. EC Proposal for a Directive of the European Parliament and of the Council on the Quality of Water Intended for Human Consumption (Recast). Available online: https://eur-lex.europa.eu/resource.html?uri=cellar:8c5065b2-074f-11e8-b8f5-01aa75ed71a1.0016.02/DOC_2&format=PDF (accessed on 1 December 2020).
  16. IMH Interministerial Decree. Scheme for the introduction. In Annex I, Part B, of the Legislative Decree 2 February 2001, n. 31, of the “Microcystin-LR” Parameter and its Parameter Value (in Italian); Italian Ministry of Health: Rome, Italy, 2012. [Google Scholar]
  17. Arnich, N. FRANCE: Regulation, Risk Management, Risk Assessment and Research on Cyanobacteria and Cyanotoxins. In Current Approaches to Cyanotoxin Risk Assessment, Risk Management and Regulations in Different Countries; Chorus, I., Ed.; Federal Environment Agency (Umweltbundesamt): Dessau-Roßlau, Germany, 2012; pp. 63–70. [Google Scholar]
  18. Government of France. Order of 11 January 2007 Relating to the Quality Limits and References for Raw Water and Water Intended for Human Consumption Mentioned in Articles R. 1321-2, R. 1321-3, R. 1321-7 and R. 1321-38 of Public Health Code; Government of France: Paris, France, 2007. (In French)
  19. Government of Canada. Guidelines for Canadian Drinking Water Quality; Water and Air Quality Bureau, Healthy Environments and Consumer Safety Branch, Health Canada; Government of Canada: Ottawa, ON, Canada, 2020; pp. 1–28.
  20. Government of Canada. Guidelines for Canadian Recreational Water Quality—Cyanobacteria and their Toxins; Government of Canada: Ottawa, ON, Canada, 2020.
  21. Australian Government. Australian Drinking Water Guidelines; Australian Government: Canberra, Australia, 2011; pp. 1–1172.
  22. Luo, Z.; Li, P.; Cai, D.; Chen, Q.; Qin, P.; Tan, T.; Cao, H. Comparison of performances of corn fiber plastic composites made from different parts of corn stalk. Ind. Crop. Prod. 2017, 95, 521–527. [Google Scholar] [CrossRef]
  23. Czyżewska, W.; Piontek, M. The Efficiency of Microstrainers Filtration in the Process of Removing Phytoplankton with Special Consideration of Cyanobacteria. Toxins 2019, 11, 285. [Google Scholar] [CrossRef] [Green Version]
  24. Lürling, M.; Kang, L.; Mucci, M.; Van Oosterhout, F.; Noyma, N.P.; Miranda, M.; Huszar, V.L.; Waajen, G.; Marinho, M.M. Coagulation and precipitation of cyanobacterial blooms. Ecol. Eng. 2020, 158, 106032. [Google Scholar] [CrossRef]
  25. Lama, S.; Muylaert, K.; Karki, T.B.; Foubert, I.; Henderson, R.K.; Vandamme, D. Flocculation properties of several microalgae and a cyanobacterium species during ferric chloride, chitosan and alkaline flocculation. Bioresour. Technol. 2016, 220, 464–470. [Google Scholar] [CrossRef] [Green Version]
  26. Jeong, B.; Oh, M.S.; Park, H.M.; Park, C.; Kim, E.J.; Hong, S.W. Elimination of microcystin-LR and residual Mn species using permanganate and powdered activated carbon: Oxidation products and pathways. Water Res. 2017, 114, 189–199. [Google Scholar] [CrossRef]
  27. Drogui, P.; Daghrir, R.; Simard, M.-C.; Sauvageau, C.; Blais, J.F. Removal of microcystin-LR from spiked water using either activated carbon or anthracite as filter material. Environ. Technol. 2011, 33, 381–391. [Google Scholar] [CrossRef]
  28. Mashile, P.P.; Mpupa, A.; Nomngongo, P.N. Adsorptive removal of microcystin-LR from surface and wastewater using tyre-based powdered activated carbon: Kinetics and isotherms. Toxicon 2018, 145, 25–31. [Google Scholar] [CrossRef]
  29. Villars, K.; Huang, Y.; Lenhart, J.J. Removal of the Cyanotoxin Microcystin-LR from Drinking Water Using Granular Activated Carbon. Environ. Eng. Sci. 2020, 37, 585–595. [Google Scholar] [CrossRef]
  30. Moon, B.R.; Kim, T.K.; Kim, M.K.; Choi, J.; Zoh, K.D. Degradation mechanisms of Microcystin-LR during UV-B photolysis and UV/H2O2 processes: Byproducts and pathways. Chemosphere 2017, 185, 1039–1047. [Google Scholar] [CrossRef] [PubMed]
  31. Park, J.A.; Yang, B.; Jang, M.; Kim, J.H.; Kim, S.B.; Park, H.D.; Park, H.M.; Lee, S.H.; Choi, J.W. Oxidation and molecular properties of microcystin-LR, microcystin-RR and anatoxin-a using UV-light-emitting diodes at 255 nm in combination with H2O2. Chem. Eng. J. 2019, 366, 423–432. [Google Scholar] [CrossRef]
  32. Park, J.A.; Yang, B.; Kim, J.H.; Choi, J.W.; Park, H.D.; Lee, S.H. Removal of microcystin-LR using UV-assisted advanced oxidation processes and optimization of photo-Fenton-like process for treating Nak-Dong River water, South Korea. Chem. Eng. J. 2018, 348, 125–134. [Google Scholar] [CrossRef]
  33. Zhu, G.; Lu, X.; Yang, Z. Characteristics of UV-MicroO 3 Reactor and Its Application to Microcystins Degradation during Surface Water Treatment. J. Chem. 2015, 2015, 1–9. [Google Scholar]
  34. Sorlini, S.; Biasibetti, M.; Collivignarelli, M.C.; Crotti, B.M. Reducing the chlorine dioxide demand in final disinfection of drinking water treatment plants using activated carbon. Environ. Technol. 2015, 36, 1499–1509. [Google Scholar] [CrossRef]
  35. Sorlini, S.; Collivignarelli, M.C.; Canato, M. Effectiveness in chlorite removal by two activated carbons under different working conditions: A laboratory study. J. Water Supply Res. Technol. 2015, 64, 450–461. [Google Scholar] [CrossRef]
  36. Sorlini, S.; Biasibetti, M.; Gialdini, F.; Collivignarelli, M.C. How can drinking water treatments influence chlorine dioxide consumption and by-product formation in final disinfection? Water Sci. Technol. Water Supply 2016, 16, 333–346. [Google Scholar] [CrossRef]
  37. Li, W.Y.; Liu, Y.; Sun, X.L.; Wang, F.; Qian, L.; Xu, C.; Zhang, J.P. Photocatalytic degradation of MC-LR in water by the UV/TiO2/H2O2 process. Water Supply 2015, 16, 34–43. [Google Scholar] [CrossRef]
  38. He, X.; Pelaez, M.; Westrick, J.A.; O’Shea, K.E.; Hiskia, A.; Triantis, T.; Kaloudis, T.; Stefan, M.I.; De La Cruz, A.A.; Dionysiou, D.D. Efficient removal of microcystin-LR by UV-C/H2O2 in synthetic and natural water samples. Water Res. 2012, 46, 1501–1510. [Google Scholar] [CrossRef]
  39. Wang, X.; Utsumi, M.; Yang, Y.; Li, D.; Zhao, Y.; Zhang, Z.; Feng, C.; Sugiura, N.; Cheng, J.J. Degradation of microcystin-LR by highly efficient AgBr/Ag3PO4/TiO2 heterojunction photocatalyst under simulated solar light irradiation. Appl. Surf. Sci. 2015, 325, 1–12. [Google Scholar] [CrossRef]
  40. Liu, J.; Ye, J.S.; Ou, H.; Lin, J. Effectiveness and intermediates of microcystin-LR degradation by UV/H2O2 via 265 nm ultraviolet light-emitting diodes. Environ. Sci. Pollut. Res. 2017, 24, 4676–4684. [Google Scholar] [CrossRef] [PubMed]
  41. Collivignarelli, M.C.; Pedrazzani, R.; Sorlini, S.; Abbà, A.; Bertanza, G. H2O2 Based Oxidation Processes for the Treatment of Real High Strength Aqueous Wastes. Sustainability 2017, 9, 244. [Google Scholar] [CrossRef] [Green Version]
  42. Li, L.; Gao, N.Y.; Deng, Y.; Yao, J.J.; Zhang, K.J.; Li, H.J.; Yin, D.D.; Ou, H.S.; Guo, J.W. Experimental and model comparisons of H2O2 assisted UV photodegradation of Microcystin-LR in simulated drinking water. J. Zhejiang Univ. A 2009, 10, 1660–1669. [Google Scholar] [CrossRef]
  43. Vlad, S.; Anderson, W.B.; Peldszus, S.; Huck, P.M. Removal of the cyanotoxin anatoxin-a by drinking water treatment processes: A review. J. Water Heal. 2014, 12, 601–617. [Google Scholar] [CrossRef] [PubMed]
  44. Loaiza-González, J.M.; Salazar, M.C.L.; Rubio-Clemente, A.; Rodriguez, D.C.; Peñuela, G.; Salazar, C.L.; Rodríguez, D.C.; Peñuela, G.A. Efficiency of the removal of microcystin-LR by UV-radiation and hydrogen peroxide. Revista Facultad de Ingeniería Universidad de Antioquia 2019, 9–19. [Google Scholar] [CrossRef] [Green Version]
  45. Penru, Y.; Guastalli, A.R.; Esplugas, S.; Baig, S. Application of UV and UV/H2O2 to seawater: Disinfection and natural organic matter removal. J. Photochem. Photobiol. A Chem. 2012, 233, 40–45. [Google Scholar] [CrossRef]
  46. Keen, O.; Bolton, J.; Litter, M.; Bircher, K.; Oppenländer, T. Standard reporting of Electrical Energy per Order (EEO) for UV/H2O2 reactors (IUPAC Technical Report). Pure Appl. Chem. 2018, 90, 1487–1499. [Google Scholar] [CrossRef] [Green Version]
  47. Schneider, M.; Bláha, L. Advanced oxidation processes for the removal of cyanobacterial toxins from drinking water. Environ. Sci. Eur. 2020, 32, 1–24. [Google Scholar] [CrossRef]
  48. Grützmacher, G.; Böttcher, G.; Chorus, I.; Bartel, H. Removal of microcystins by slow sand filtration. Environ. Toxicol. 2002, 17, 386–394. [Google Scholar] [CrossRef]
  49. Jeon, Y.; Li, L.; Calvillo, J.; Ryu, H.; Domingo, J.W.S.; Choi, O.; Brown, J.; Seo, Y. Impact of algal organic matter on the performance, cyanotoxin removal, and biofilms of biologically-active filtration systems. Water Res. 2020, 184, 116120. [Google Scholar] [CrossRef]
  50. Klassen, N.V.; Marchington, D.; McGowan, H.C. H2O2 Determination by the I3- Method and by KMnO4 Titration. Anal. Chem. 1994, 66, 2921–2925. [Google Scholar] [CrossRef]
  51. Rahn, R.O.; Bolton, J.; Stefan, M.I. The Iodide/Iodate Actinometer in UV Disinfection: Determination of the Fluence Rate Distribution in UV Reactors. Photochem. Photobiol. 2006, 82, 611–615. [Google Scholar] [CrossRef] [PubMed]
  52. Liu, W.; Andrews, S.; Stefan, M.I.; Bolton, J.R. Optimal methods for quenching H2O2 residuals prior to UFC testing. Water Res. 2003, 37, 3697–3703. [Google Scholar] [CrossRef]
  53. Collivignarelli, M.C.; Abbà, A.; Miino, M.C.; Arab, H.; Bestetti, M.; Franz, S. Decolorization and biodegradability of a real pharmaceutical wastewater treated by H2O2-assisted photoelectrocatalysis on TiO2 meshes. J. Hazard. Mater. 2020, 387, 121668. [Google Scholar] [CrossRef] [PubMed]
  54. Malpass, G.R.P.; Miwa, D.; Mortari, D.; Machado, S.; Motheo, A. Decolorisation of real textile waste using electrochemical techniques: Effect of the chloride concentration. Water Res. 2007, 41, 2969–2977. [Google Scholar] [CrossRef] [PubMed]
  55. Farkas, J.; Náfrádi, M.; Hlogyik, T.; Pravda, B.C.; Gajda-Schrantz, K.; Hernádi, K.; Alapi, T. Comparison of advanced oxidation processes in the decomposition of diuron and monuron–efficiency, intermediates, electrical energy per order and the effect of various matrices. Environ. Sci. Water Res. Technol. 2018, 4, 1345–1360. [Google Scholar] [CrossRef] [Green Version]
  56. Zhang, R.; Yang, Y.; Huang, C.-H.; Zhao, L.; Sun, P. Kinetics and modeling of sulfonamide antibiotic degradation in wastewater and human urine by UV/H2O2 and UV/PDS. Water Res. 2016, 103, 283–292. [Google Scholar] [CrossRef]
  57. Yao, H.; Sun, P.; Minakata, D.; Crittenden, J.C.; Huang, C.-H. Kinetics and Modeling of Degradation of Ionophore Antibiotics by UV and UV/H2O2. Environ. Sci. Technol. 2013, 47, 4581–4589. [Google Scholar] [CrossRef]
  58. Sun, P.; Tyree, C.; Huang, C.-H. Inactivation of Escherichia coli, Bacteriophage MS2, and Bacillus Spores under UV/H2O2 and UV/Peroxydisulfate Advanced Disinfection Conditions. Environ. Sci. Technol. 2016, 50, 4448–4458. [Google Scholar] [CrossRef]
Figure 1. Degradation of MC-LR as a function of UV fluence in H2O2 alone, UV and UV/H2O2 processes. The colored curves represent exponential decay curve fitting. Error bars represent the confidence interval (n = 3). In case of the H2O2 alone treatment, the samples were taken at the time interval corresponding to the same UV fluence of the other tests. Conditions: MC-LR0 = 50 µg L−1; pH = 7.5 and fluence rate = 0.2 mW cm−2.
Figure 1. Degradation of MC-LR as a function of UV fluence in H2O2 alone, UV and UV/H2O2 processes. The colored curves represent exponential decay curve fitting. Error bars represent the confidence interval (n = 3). In case of the H2O2 alone treatment, the samples were taken at the time interval corresponding to the same UV fluence of the other tests. Conditions: MC-LR0 = 50 µg L−1; pH = 7.5 and fluence rate = 0.2 mW cm−2.
Toxins 12 00810 g001
Figure 2. (a) First-order kinetic constant (ktime) and half-life time (HLT) during degradation by UV and UV/H2O2. (b) First-order kinetic constant (kfluence) as a function of the H2O2 dosage. Conditions: MC-LR0 = 50 µg L−1; pH = 7.5; fluence rate = 0.2 mW cm−2 and n: number of data.
Figure 2. (a) First-order kinetic constant (ktime) and half-life time (HLT) during degradation by UV and UV/H2O2. (b) First-order kinetic constant (kfluence) as a function of the H2O2 dosage. Conditions: MC-LR0 = 50 µg L−1; pH = 7.5; fluence rate = 0.2 mW cm−2 and n: number of data.
Toxins 12 00810 g002
Figure 3. (a) H2O2 consumption as a function of H2O2 dosage. (b) H2O2 efficiency as a function of H2O2 consumption. Conditions: MC-LR0 = 50 µg L−1; pH = 7.5 and fluence rate = 0.2 mW cm−2.
Figure 3. (a) H2O2 consumption as a function of H2O2 dosage. (b) H2O2 efficiency as a function of H2O2 consumption. Conditions: MC-LR0 = 50 µg L−1; pH = 7.5 and fluence rate = 0.2 mW cm−2.
Toxins 12 00810 g003
Figure 4. Degradation of MC-LR as a function of UV fluence in UV/H2O2 processes with different initial toxin concentration. The colored curves represent exponential decay curve fitting. Error bars represent the confidence interval (n = 3). Conditions: H2O2 dosage = 0.3 mM; pH = 7.5 and fluence rate = 0.2 mW cm−2.
Figure 4. Degradation of MC-LR as a function of UV fluence in UV/H2O2 processes with different initial toxin concentration. The colored curves represent exponential decay curve fitting. Error bars represent the confidence interval (n = 3). Conditions: H2O2 dosage = 0.3 mM; pH = 7.5 and fluence rate = 0.2 mW cm−2.
Toxins 12 00810 g004
Figure 5. First-order kinetic constant (kfluence) as a function of the initial MC-LR concentration (MC-LR0). Conditions: H2O2 dosage = 0.3 mM; pH = 7.5 and fluence rate = 0.2 mW cm−2.
Figure 5. First-order kinetic constant (kfluence) as a function of the initial MC-LR concentration (MC-LR0). Conditions: H2O2 dosage = 0.3 mM; pH = 7.5 and fluence rate = 0.2 mW cm−2.
Toxins 12 00810 g005
Figure 6. Total electrical energy per order (EEO), by different H2O2 dosage, as a function of UV fluence. Conditions: MC-LR0 = 50 µg L−1; pH = 7.5 and fluence rate = 0.2 mW cm−2.
Figure 6. Total electrical energy per order (EEO), by different H2O2 dosage, as a function of UV fluence. Conditions: MC-LR0 = 50 µg L−1; pH = 7.5 and fluence rate = 0.2 mW cm−2.
Toxins 12 00810 g006
Figure 7. Scheme of the reactor used in test with UV, H2O2 and UV/H2O2.
Figure 7. Scheme of the reactor used in test with UV, H2O2 and UV/H2O2.
Toxins 12 00810 g007
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Sorlini, S.; Collivignarelli, C.; Carnevale Miino, M.; Caccamo, F.M.; Collivignarelli, M.C. Kinetics of Microcystin-LR Removal in a Real Lake Water by UV/H2O2 Treatment and Analysis of Specific Energy Consumption. Toxins 2020, 12, 810. https://0-doi-org.brum.beds.ac.uk/10.3390/toxins12120810

AMA Style

Sorlini S, Collivignarelli C, Carnevale Miino M, Caccamo FM, Collivignarelli MC. Kinetics of Microcystin-LR Removal in a Real Lake Water by UV/H2O2 Treatment and Analysis of Specific Energy Consumption. Toxins. 2020; 12(12):810. https://0-doi-org.brum.beds.ac.uk/10.3390/toxins12120810

Chicago/Turabian Style

Sorlini, Sabrina, Carlo Collivignarelli, Marco Carnevale Miino, Francesca Maria Caccamo, and Maria Cristina Collivignarelli. 2020. "Kinetics of Microcystin-LR Removal in a Real Lake Water by UV/H2O2 Treatment and Analysis of Specific Energy Consumption" Toxins 12, no. 12: 810. https://0-doi-org.brum.beds.ac.uk/10.3390/toxins12120810

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop