Article

Linear Models for the Prediction of Animal Zone Ammonia in a Weaned Piglet Building

1
Department of Agroforestry Engineering, University of Santiago de Compostela, Escola Politécnica Superior de Enxeñaría, Campus Terra, s/n, 27002 Lugo, Spain
2
Departamento Producción Animal, Centro de Investigaciones Agrarias de Mabegondo (CIAM), Agencia Gallega de Calidad Alimentaria (AGACAL), 15318 A Coruña, Spain
3
Xunta de Galicia, Oficina Agraria Comarcal Lalín, Rúa Areal, 27, 36500 Pontevedra, Spain
*
Author to whom correspondence should be addressed.
Submission received: 20 August 2021 / Revised: 17 September 2021 / Accepted: 22 September 2021 / Published: 25 September 2021
(This article belongs to the Special Issue Papers from AgEng2021)

Abstract

:
Measuring ammonia inside livestock buildings poses many challenges that hinder the incorporation of this variable into environmental control systems. The aim of this study was to measure various microclimate variables inside a weaned piglet building and analyse their interactions with NH3 concentrations for setpoint temperatures of 26 and 25 °C, in order to control NH3 concentrations based on other easily measurable variables. The experimental test was conducted on a conventional farm in Northwest Spain. NH3 concentrations in the animal zone were best correlated with CO2 concentrations in the animal zone (R = 0.91 and R = 0.55) and velocity of air extracted through the fan (R = 0.72 and R = 0.65) for setpoint temperatures of 26 and 25 °C, respectively. Similarly, strong correlations were found with relative humidity in the animal zone and temperature of inlet air. Because NH3 concentration in the animal zone is related to the performance of the ventilation system, strong positive correlations were found between NH3 concentration and temperature of inlet air whereas negative correlations were found between NH3 concentration and ventilation rates. Linear regression models based on CO2 concentrations in the animal zone and temperature of inlet air are recommended, because they provide a good fit for both setpoint temperatures using variables that can be readily measured.

1. Introduction

In recent years, the gradual intensification of animal production has brought about many new environmental problems. At the same time, there has been a growing public awareness of the need to protect and respect animals, which has led to market initiatives for pork production systems with increased animal welfare [1]. In the near future, animal welfare, food safety and respect for the environment will be major challenges for pig production. In this context, indoor climate control in livestock buildings becomes crucial to the welfare, health and productivity of animals. Among other parameters, indoor climate control includes temperature, relative humidity, and air velocity and quality, which is defined in terms of microorganisms including pathogens, concentration of airborne contaminants such as dust, ammonia (NH3), carbon monoxide (CO), carbon dioxide (CO2) [2] or hydrogen sulphide (H2S) and methane (CH4). Therefore, indoor climate in livestock buildings deserves particular attention because it affects animal health and welfare, animal production, workers’ health and the environment. Indeed, a well-designed environmental control system is the most efficient tool to ensure optimal production in livestock housing [3].
From among all the gases found in livestock buildings with the potential adverse effects of emissions, NH3 requires an in-depth analysis [4] because of the impact of high NH3 concentration levels on animal health and production [5,6,7] and farm workers’ health [6].
Generally, the responses of pigs to their environment are complex and difficult to assess, and there is relatively little information available on their reaction to air pollutants [8]. Yet, it has been shown that ammonia can affect animal health and productivity, and the effects depend on concentration levels and exposure times [9,10,11]. A number of authors have shown that exposing pigs to NH3 concentrations of 6 and 13 ppm [12] or up to 37 ppm [13] does not affect production efficiency. Such disparate concentrations suggest that more research is needed in order to find more conclusive values [8]. Hence, no official NH3 exposure limits have been established for the occurrence of adverse health effects on pig growth [7] even though several studies have recommended maximum NH3 levels in swine buildings between 7 and 15 ppm [14,15] or even 20 ppm [13,16]. In any case, several studies have reported measured ammonia concentration levels below those values [17,18].
Measuring gaseous emissions from livestock buildings, particularly under commercial conditions, is a challenging task that is subject to various uncertainty sources [19].
Actually, gas concentrations vary according to the airflow pattern and depend greatly on the ventilation system, among other variables [4,20,21], i.e., the temperature, the feeding of animals, their metabolism and the housing system. Ammonia concentrations can be measured with a variety of sensors, among which semiconductor, infrared, photoacoustic and electrochemical detectors. However, all of them show weaknesses for real-time monitoring of ammonia and many of them show a limited useful life, and require continuous maintenance and frequent calibration. In addition, the effect of sensor location is affected by the time and duration of measurements due to variations in the level of animal activity through time across different life stages [22] and to daily and seasonal variations in gas concentrations [17,23]. As a result, considerable efforts have been made to: (1) understand the mechanisms of ammonia emission [4,20,24], (2) solve measurement accuracy issues [19,22,25] and (3) reduce ammonia emissions [22,26]. Because current knowledge and measurement techniques can only provide reasonable estimates of ammonia emissions, there is a need for improved measurement techniques that allow for more accurate emission rate inventories [22]. Thus, it is essential to accurately measure NH3 concentration inside the building. Nevertheless, electrochemical sensors are often used in real-time monitoring of gaseous emissions in livestock buildings [15,17,25] because of their small size and fast response times [27].
The aims of this paper are to analyse the interactions between microclimate variables, focusing on NH3 concentration, and to develop its prediction from other more easily measurable microclimate variables, such as humidity, temperature, CO2 concentration or air velocity inside the building.

2. Materials and Methods

2.1. Experimental Test

2.1.1. Animals and Housing

An experimental test was conducted on a commercial pig farm located in northwest Spain (ETRS89. 43°10′12′′ N, 8°19′30′′ W). The farm housed weaned piglets of 20 kg live weight and was the largest in the study area, with a maximum capacity of 4985 sows.
The weaner room, with an area of 69.26 m2 and a volume of 164.50 m3, consisted of twelve 2.55 × 1.97 m pens on both sides of a central aisle. The room could hold a maximum of 300 piglets, with an area of 0.20 m2 per piglet. The piglets, which were Large White × Landrace hybrids weaned at 3 weeks of age, entered the room on February 25 and exited the room on April 8. The floor was completely slatted over a pit with a depth of 45 cm. The negative pressure ventilation system was composed of a helical extractor fan, model EU50, EXAFAN ©, Zaragoza, Spain, of 500 mm of diameter, 230 VAC, 50 Hz, 1330 rpm and 480 W with a maximum volume of 8746 m3h−1. Fan speed was adjusted by changing the voltage using a temperature-based digital controller, which allowed ventilation rates between 25% and 100% and bandwidth temperatures of ±1.5 °C. Additionally, the ventilation rate was modulated with a manual system that reduced the area of the air outlet through the fan and provided volumes of between 1.03 and 10.58 m3h−1 per piglet. Fresh air entered the room through two 0.70 m2 windows with manually controlled air deflectors. The radiant floor heating system was composed of two 1.20 × 0.50 m polyester spreader plates for water, with 19 l capacity, placed at the center of each pen. The average temperature of the plates was 30.60 °C, with a mean difference between inlet and outlet temperature of 5.80 °C. The heating system was controlled with a manual valve.

2.1.2. Variables and Measurement

The following microclimate variables were measured (Figure 1): Temperature of air in external corridor (TCA), velocity of the air extracted through the ventilation system (VEX), and temperature, relative humidity, air velocity and CO2 and NH3 concentrations in the animal zone (T, RH, VIN, CO2, NH3). TCA was recorded using a BetaTherm 100K6A1B Thermistor sensor (Campbell Scientific ©, Loughborough, UK), with a measurement range of −5–95 °C and ±0.5 °C accuracy from −5 °C to 90 °C. The sensor was placed at 1.80 m height outside the room, in the external corridor (Figure 1). VEX was measured using an active air speed transmitter (Delta Ohm HD2903TTC310, Selvazzano Dentro, Italy) with a measurement range of 0.20–20 ms−1 and an accuracy of ±0.4 ms−1 + 3% of measurement (Figure 1). The transmitter was installed in a 0.55 × 0.55 m duct with a length of 1.20 m, fixed to the fan outlet, according to the method proposed by [28], and was adapted to the hotwire probe used.
The sensors located in the animal zone were placed in a pen that was representative of room conditions. Sensors were arranged inside a protection cage at 0.2 m height above the slats to reduce the risk of destruction by the animals (Figure 1). T and RH were measured using a Temperature/RH smart sensor (ONSET® S-THB-M002, Bourne, MA, USA) with a measurement range of −40–75 °C and accuracies of ±0.2 °C for temperature and ±2.5% for humidity. To measure VIN, a hotwire probe (Delta Ohm HD103T.0, Selvazzano Dentro, Italy) with a measurement range of 0–5 ms−1 and ±0.06 ms−1 accuracy was used. CO2 was measured using a transmitter (Delta Ohm HD37BTV.1, Selvazzano Dentro, Italy) with a measurement range of 0–5000 ppm and 50 ppm ±4% accuracy. Finally, NH3 was measured by using an electrochemical sensor MGS 150 (Murco ©, Dublin, Ireland), with a measurement range of 0–100 ppm and accuracy from −40 to +40 °C < 1 ppm. The 10-min averages of the measured values were stored at 1-sec intervals in a HOBO® data logger (Bourne, MA, USA), and a CR-10X Campbell Scientific (Loughborough, UK). The electrochemical sensors used were suitable for use in livestock housing. Nevertheless, the sensors showed some problems, among which saturation after long exposures, need for regular maintenance and low sensitivity. The first two issues were minimized by using the equipment in short periods, with the required maintenance tasks. However, sensitivity is inherent to the sensor and affects mainly measurements of low concentrations. In order to improve data accuracy, each day with the same TS was considered as a repeated measurement. Under this consideration, two standard days were prepared, one for each TS (26 and 25 °C), by calculating the hourly average for every day, which resulted in values more indicative of daily variation.

2.2. Data Analysis

Data were collected at setpoint temperatures (TS) of 26 and 25 °C between March 2 and 17 March 2013, which corresponded to days 5 to 22 after weaning. We chose this study period because of the type of sensor used, which saturates and loses reliability for continuous measurements performed in long periods (more than 20 days). The 10-min averages of the measured values were transformed into hourly averages (H) because the dynamics of the processes associated with the distribution of heat and diffusion of gases did not allow us to establish good linear relationships at shorter times. In order to obtain the daily evolution of the variables, the hourly mean values were calculated for every day (D) in the study period.
A statistical analysis was carried out using IBM SPSS Statistics V22.0 (SPSS: Chicago, IL, USA)for Windows. To demonstrate the effect of TS on NH3, an independent-samples T test was conducted. For that purpose, once the Box-cox transformation was applied, the normality of concentrations of NH3 was checked through the Kolmogorov-Smirnov statistic. Results were higher than 0.05 for both setpoint temperatures (0.20 and 0.07 for TS of 26 ° and 25 °C respectively). Thus, concentrations of NH3 for both temperatures derive from normal populations. After that, we worked with two different datasets based on TS, TS = 26 °C or TS = 25 °C [17].
The correlations between the seven study variables were assessed by examining the correlation matrices and testing the significance between variables (NH3, CO2, T, TCA, RH, VIN, VEX).
From the resulting correlation table, we selected the variables with the highest and most significant values of r with variable (NH3) in order to perform a regression analysis for both groups (26 and 25 °C setpoint temperatures), thus excluding the variables with low or non-significant correlations. Following these criteria, a simple regression analysis was performed between NH3, CO2, RH, TCA, VEX for TS = 26 °C and NH3 and VEX for TS = 25 °C.
Data analysis was performed by using multiple regressions, in which the dependent variable was NH3. The maximum number of independent variables that could be included in the regression model was nine. However, this did not mean that the effect of all the parameters was necessarily significant.
In Forward Stepwise Regression, variables are added sequentially into the model. The first variable added into the model is the one that shows the strongest correlation (+ or −) with the dependent variable. This variable is added into the equation only if it meets the entry criteria (significance of the term and criteria of global adjustment). Next, the independent variable with the highest partial correlation (out of those that are not already in the equation) is added into the model. The process ends when there are no more variables left that meet the entry criteria. In this work, we used an SPSS procedure that performed all possible subset regressions.

3. Results and Discussion

3.1. Concentration of NH3 for TS 26 and 25 °C

For both setpoint temperatures, daily mean NH3 concentrations (Figure 2) were well below the strict safe exposure limits set by [11] at 10 ppm, and most of the time below the 7 ppm established by [16]. Piglets were in a clean environment, with concentrations below 6 ± 0.5 ppm [12], for 85.32% and 66.67% of the time for 26 and 25 °C, respectively, and exceeded this limit only for 14.68% (26 °C) and 33.33% (25 °C) of the time.

3.2. Correlations between the Study Variables for TS 26 and 25 °C

Except for VIN, stronger correlations were found for TS = 26 °C than for TS = 25 °C (Table 1), which suggests an important effect of TS on the dynamics of mass and energy flows that occur in the building. A strong correlation was found between NH3 and CO2 concentrations, with values of 0.91 and 0.55 for 26 and 25 °C, respectively. These values are in agreement with the values reported by other authors [29,30,31].
The difference between the correlations found for the concentrations of NH3 and CO2 for the two TS was evident and was related to the performance of the ventilation system. The lowest TS (25 °C) showed lower correlations because the ventilation system was much more efficient in removing NH3 than CO2, due to the dynamics of the gases in the building, caused by the difference in density between both gases. CO2 accumulates in lower layers of the building and is more difficult to extract, whereas NH3 is on the upper layers, and thus easier to extract.
The correlation between T and NH3 was near zero for both TS, which is in contrast with the findings reported by other authors [30]. Such a null correlation was due to the capacity of the climate control system which was composed of ventilation and heating to keep temperature in the animal zone (T) almost constant at the desired values.
For both TS, a negative correlation was found between NH3 and TCA, with higher values for 26 °C (−0.80) than for 25 °C (−0.29), which is in agreement with [20]. This effect can be explained by the ventilation rates [32]. When the outdoor temperatures drop, there is a decrease in the ventilation rate inside the building, with the consequent increase in NH3 concentration. This has been confirmed in our study, with correlations between ventilation (VEX) and NH3 of −0.72 and −0.65 for 26 and 25 °C, respectively.
For VIN, which indirectly characterizes ventilation, correlations with NH3 were −0.35 for 25 °C and almost null for 26 °C. Higher values of NH3 during the night are indicative of a low ventilation rate, which suggests that the system could not extract all the NH3 produced.
Correlations between RH and NH3 were in the range 0.78 and 0.16 for TS = 26 °C and TS = 25 °C, respectively. The value obtained for 26 °C was similar to the value reported by [30], and intermediate with respect to the values reported by [24,33].

3.3. Linear Regression Models of NH3 from Mean Hourly Data

Statistical significance shows the predictor variables included in the analyses that are significant at 95% confidence level. To check for collinearity in the model, two indicators were used: tolerance (T’) and variance inflation factor (VIF). A multicollinearity problem occurs when tolerance is < 0.10 and VIF is higher than 10. Therefore, no multicollinearity was found among variables.
To study independence and lack of correlation between residuals (the difference between observed values and predicted values), we used the Durbin-Watson statistic, which varies from 0 to 4. When the DW statistic takes values in the range of 1.5 to 2.5, the residuals are assumed to be independent [34]. Therefore, no autocorrelation was observed in the models in accordance with the DW statistic, as shown in Table 2. All the models are significant and suggest a significant linear relationship. The significance of each variable is explained for each model. The result of the analysis of variance (ANOVA) indicates whether the model is significant as a whole. The sum of squares of the regression indicates which part of the variability of the dependent variable explains the model, and the sum of squares of the residuals indicates which part does not explain it. The F statistic indicates the predictive function of the regression model, determining whether every regression coefficient is significantly different to 0. The F test analyses the combined influence of explicative variables, instead of individually evaluating each explicative variable. The F statistical indicator presents an associated p value, which indicates the probability of the relationships between data being caused through chance. A small p value is required, normally less than or equal to 0.05, in order to determine that the relationships of the model are not caused by coincidence. The p-value is lower than 0.05 for all the models so every model is significant (Table 3).
The first model proposed in our study, model 26H-1, predicted the interactions between CO2 and NH3 concentrations (Table 2) and yielded an adjusted R2 value of 0.83, with a standard error (SE) of the estimate of 0.97 ppm. Model 26H-2 considered RH as the independent variable and yielded an R2 of 0.60 with an SE of 1.49 ppm. Despite the poorer fit of model 26H-2 with respect to the first model, model 26H-2 is interesting because it reveals that keeping humidity at low levels ensures low concentrations of NH3.
Model 26H-3, for the relationship between TCA and NH3, yielded an R2 of 0.64 and improved the prediction of NH3 slightly as compared to model 26H-2. This finding is interesting because model 26H-3 incorporates an easily measurable variable, TCA. Model 26H-3 considerably improves the model proposed by [35] who, using non-continuous measurements, reported values between 0.95 and 0.97 for dairy cattle. Such an improvement could be explained in terms of the differences between forced ventilation and natural ventilation.
Model 26H-4 included VEX as the independent variable and showed poorer results (R2 = 0.52) that were in agreement with the values reported by [36] and below those reported by [37].
Incorporating TCA, model 26H-5, or VEX, model 26H-6, into model 26H-1 slightly improved the predictions, with R2 values of 0.86 and 0.84, respectively. Model 26H-8 yielded the best results, with an R2 of 0.87 and an SE of 0.86 ppm, Yet, as with the previous models, model 26H-8 is not interesting from a practical standpoint because only the models requiring fewer, easily measurable variables can be incorporated into microclimate control in the building in terms of ammonia concentration. The standardized coefficients suggest that RH has a slightly greater effect on the prediction of NH3 than TCA.
As regards the regression models for TS = 25 °C, model 25H-1, with VEX as the independent variable, showed an R2 of 0.42, which is lower that the value reported by [37]. Incorporating new variables into the model produced slight improvements, such that the best results were obtained with model 25H-4, which yielded an R2 of 0.53. Yet, the main drawback of model 25H-4 is the need to incorporate four variables into the control system. For a setpoint temperature of 25 °C, the standardized coefficients suggest that VEX is the variable with the greatest impact on the dependent variable, which implies that ventilation is essential in the determination and prediction of NH3 concentrations, which is in agreement with the findings reported by [37].

3.4. Linear Regression Models of NH3 from Mean Daily Data

Models built from mean daily data (Table 4) using a single variable did not improve the results for TS = 26 °C, even though the SE was considerably lower. On the contrary, models built from mean daily data improved considerably for TS = 25 °C. No multicollinearity was found among variables neither autocorrelation was observed in the models in accordance with the DW statistic. All the models are significant and suggest a significant linear relationship (Table 5).
Overall, the accuracy of the models built from mean daily data (Table 4) did not improve for TS = 26 °C, even though these models showed a notably lower SE. Conversely, for TS = 25 °C, the goodness of fit increased considerably and the SE decreased. For both TS, the models incorporating VEX, TCA or CO2 as the single control variable produced remarkable results, which did not sensibly improve by adding new variables to the model. Consequently, these models provide an efficient and inexpensive method for the control of NH3 concentrations insofar as they use a single variable that can be readily measured.

3.5. Research Limitations

This study was performed on a single farm without considering the heterogeneity of the air inside the building. Yet, measurements of CO2 and NH3 concentration, relative humidity and temperature were carried out at a location that was representative of the environment in the animal zone.

4. Conclusions

The following conclusions can be drawn from the analysis of microclimate variables, particularly NH3 concentration and its prediction from other inexpensive, easily measurable microclimate variables:
NH3 concentration in the animal zone correlates positively with CO2 concentration and relative humidity in the animal zone for setpoint temperatures of 26 and 25 °C. In addition, because NH3 concentration is directly related to the performance of the ventilation system, the correlation coefficients are strong and negative for air velocity extracted through the ventilation system and positive for temperature of air in the external corridor, which is not environmentally controlled and, therefore, shows a linear relation with outdoor temperature.
For a setpoint temperature of 26 °C, the variables that yield the best linear models are temperature of air in external corridor and CO2 concentration, both for daily and hourly data. For 25 °C, the velocity of the air extracted through the ventilation system gains relevance and can be compared to the temperature of air in the external corridor.
Based on these differences, linear regression models based on CO2 concentration in the animal zone and temperature of air in external corridor using mean daily values are recommended, because these models provide good fits for both setpoint temperatures using variables that require simpler measuring technology.

Author Contributions

Conceptualization, M.D.F. and M.R.R.; methodology, T.A. and M.D.F.; validation, T.A., M.D.F. and J.A.O.; formal analysis, Á.C. and T.A.; investigation, M.D.F., R.B., J.A.O. and M.R.R.; data curation, T.A. and J.A.O.; writing—original draft preparation, T.A. and M.R.R.; writing—review and editing, T.A. and M.R.R.; supervision, Á.C. and M.D.F. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by Consellería de Educación, Universidade e Formación Profesional and Consellería de Economía, Emprego e Industria da Xunta de Galicia, grant number ED431B 2018/12-GPC.

Data Availability Statement

Publicly available datasets were analyzed in this study. This data can be found here: https://www.dropbox.com/sh/njbugesrtr7omks/AADbL7geDiaj-shRA48S9hSva?dl=0.

Acknowledgments

The authors are grateful to the regional government Xunta de Galicia for funding this research through the “Program of consolidation and structuring of competitive research units” (ED431B 2018/12).

Conflicts of Interest

The authors have declared that no competing interests exist.

References

  1. De Greef, K.H.; Vermeer, H.M.; Houwers, H.W.J.; Bos, A.P. Proof of principle of the comfort class concept in pigs: Experimenting in the midst of a stakeholder process on pig welfare. Livest. Sci. 2011, 139, 172–185. [Google Scholar] [CrossRef]
  2. Park, J.H.; Peters, T.M.; Altmaier, R.; Sawvel, R.A.; Anthony, T.R. Simulation of air quality and cost to ventilate swine farrowing facilities in winter. Comput. Electron. Agric. 2013, 98, 136–145. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  3. Garcimartín, M.A.; Ovejero, I.; Sanchez, E.; Sanchez-Giron, V. Application of the sensible heat balance to determine the temperature tolerance of commercial poultry housing. World’s Poult. Sci. J. 2007, 63, 575–584. [Google Scholar] [CrossRef]
  4. Rong, L.; Aarnink, A.J.A. Development of ammonia mass transfer coefficient models for the atmosphere above two types of the slatted floors in a pig house using computational fluid dynamics. Biosyst. Eng. 2019, 183, 13–25. [Google Scholar] [CrossRef]
  5. Wang, X.; Wang, M.; Chen, S.; Wei, B.; Gao, Y.; Huang, L.; Liu, C.; Huang, T.; Yu, M.; Zhao, S.H.; et al. Ammonia exposure causes lung injuries and disturbs pulmonary circadian clock gene network in a pig study. Ecotoxicol. Environ. Saf. 2020, 205, 111050. [Google Scholar] [CrossRef]
  6. Xie, Q.; Ni, J.Q.; Su, Z. A prediction model of ammonia emission from a fattening pig room based on the indoor concentration using adaptive neuro fuzzy inference system. J. Hazard. Mater. 2017, 325, 301–309. [Google Scholar] [CrossRef]
  7. Kim, K.Y.; Ko, H.J.; Kim, H.T.; Kim, C.N.; Byeon, S.H. Association between pig activity and environmental factors in pig confinement buildings. Aust. J. Exp. Agric. 2008, 48, 680–686. [Google Scholar] [CrossRef]
  8. Michiels, A.; Piepers, S.; Ulens, T.; Van Ransbeeck, N.; Sacristán, R.D.P.; Sierens, A.; Haesebrouck, F.; Demeyer, P.; Maes, D. Impact of particulate matter and ammonia on average daily weight gain, mortality and lung lesions in pigs. Prev. Vet. Med. 2015, 121, 99–107. [Google Scholar] [CrossRef]
  9. Gustafsson, G.; Banhazi, T.; Jeppsson, K.H. Control of emission from livestock buildings and the impact on health, welfare and performance of animals: A review. In Livestock Housing: Modern Management to Ensure Optimal Health and Welfare of Farm Animals; Aland, A., Banhazi, T., Eds.; Wageningen Academic Publishers: Wageningen, The Netherlands, 2013; pp. 261–280. [Google Scholar]
  10. Banhazi, T.M.; Seedorf, J.; Rutley, D.L.; Pitchford, W.S. Identification of risk factors for sub-optimal housing conditions in Australian piggeries: Part 1. Study justification and design. J. Agric. Saf. Health 2008, 14, 5–20. [Google Scholar] [CrossRef]
  11. Cargill, C.; Murphy, T.; Banhazi, T. Hygiene and air quality in intensive housing facilities in Australia. Anim. Prod. Aust. 2002, 24, 387–393. [Google Scholar]
  12. Lee, C.; Giles, L.R.; Bryden, W.L.; Downing, J.L.; Owens, P.C.; Kirby, A.C.; Wynn, P.C. Performance and endocrine responses of group housed weaner pigs exposed to the air quality of a commercial environment. Livest. Prod. Sci. 2005, 93, 255–262. [Google Scholar] [CrossRef]
  13. Wathes, C.M.; Demmers, T.G.M.; Teer, N.; White, R.P.; Taylor, L.L.; Bland, V.; Jones, P.; Armstrong, D.; Gresham, A.C.J.; Hartung, J.; et al. Production responses of weaned pigs after chronic exposure to airborne dust and ammonia. Anim. Sci. 2004, 78, 87–97. [Google Scholar] [CrossRef]
  14. Costa, A. Ammonia concentrations and emissions from finishing pigs reared in different growing rooms. J. Environ. Qual. 2017, 46, 255–260. [Google Scholar] [CrossRef]
  15. Banhazi, T.M.; Seedorf, J.; Rutley, D.L.; Pitchford, W.S. Identification of risk factors for sub-optimal housing conditions in Australian piggeries: Part 2. Airborne pollutants. J. Agric. Saf. Health 2008, 14, 21–39. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  16. Donham, K.; Thorne, P.; Breuer, G.; Powers, W.; Marquez, S.; Reynolds, S. Exposure Limits Related to Air Quality and Risk Assessment. Iowa Concentrated Animal Feeding Operations Air Quality Study; Iowa State University and The University of Iowa Study Group: Iowa City, IA, USA, 2002; p. 164. [Google Scholar]
  17. Rodríguez, M.R.; Losada, E.; Besteiro, R.; Arango, T.; Velo, R.; Ortega, J.A.; Fernandez, M.D. Evolution of NH3 Concentrations in Weaner Pig Buildings Based on Setpoint Temperature. Agronomy 2020, 10, 107. [Google Scholar] [CrossRef] [Green Version]
  18. Zong, C.; Li, H.; Zhang, G. Ammonia and greenhouse gas emissions from fattening pig house with two types of partial pit ventilation systems. Agric. Ecosyst. Environ. 2015, 208, 94–105. [Google Scholar] [CrossRef]
  19. Calvet, S.; Gates, R.S.; Zhang, G.; Estelles, F.; Ogink, N.W.; Pedersen, S.; Berckmans, D. Measuring gas emissions from livestock buildings: A review on uncertainty analysis and error sources. Biosyst. Eng. 2013, 116, 221–231. [Google Scholar] [CrossRef] [Green Version]
  20. Rosa, E.; Mosquera, J.; Arriaga, H.; Montalvo, G.; Merino, P. Ammonia emission modelling and reduced sampling strategies in cage-based laying hen facilities. Biosyst. Eng. 2021, 204, 304–311. [Google Scholar] [CrossRef]
  21. Tabase, R.K.; Millet, S.; Brusselman, E.; Ampe, B.; De Cuyper, C.; Sonck, B.; Demeyer, P. Effect of ventilation control settings on ammonia and odour emissions from a pig rearing building. Biosyst. Eng. 2020, 192, 215–231. [Google Scholar] [CrossRef]
  22. Takai, H.; Nimmermark, S.; Banhazi, T.; Norton, T.; Jacobson, L.D.; Calvet, S.; Hassouna, M.; Bjerg, B.; Zhang, G.; Pedersen, S.; et al. Airborne pollutant emissions from naturally ventilated buildings: Proposed research directions. Biosyst. Eng. 2013, 116, 214–220. [Google Scholar] [CrossRef] [Green Version]
  23. Calvet, S.; Cambra-López, M.; Estelles, F.; Torres, A.G. Characterization of gas emissions from a Mediterranean broiler farm. Poult. Sci. 2011, 90, 534–542. [Google Scholar] [CrossRef] [PubMed]
  24. Ni, J.Q.; Liu, S.; Diehl, C.A.; Lim, T.T.; Bogan, B.W.; Chen, L.; Heber, A.J. Emission factors and characteristics of ammonia, hydrogen sulfide, carbon dioxide, and particulate matter at two high-rise layer hen houses. Atmos. Environ. 2017, 154, 260–273. [Google Scholar] [CrossRef]
  25. Ogink, N.W.; Mosquera, J.; Calvet, S.; Zhang, G. Methods for measuring gas emissions from naturally ventilated livestock buildings: Developments over the last decade and perspectives for improvement. Biosyst. Eng. 2013, 116, 297–308. [Google Scholar] [CrossRef]
  26. Calvet, S.; Hunt, J.; Misselbrook, T.H. Low frequency aeration of pig slurry affects slurry characteristics and emissions of greenhouse gases and ammonia. Biosyst. Eng. 2017, 159, 121–132. [Google Scholar] [CrossRef] [PubMed]
  27. Zhang, S.R.; Wang, J.H.; Dong, D.M.; Zheng, W.G.; Zhao, X.D. A review of contact sensors used for monitoring malodorous gas in animal facilities. Adv. Mat. Res. 2013, 629, 655–661. [Google Scholar] [CrossRef]
  28. Hinz, T.; Linke, S. A comprehensive experimental study of aerial pollutants in and emissions from livestock buildings. Part 1. Methods. J. Agric. Eng. Res. 1998, 70, 111–118. [Google Scholar] [CrossRef]
  29. Philippe, F.X.; Laitat, M.; Canart, B.; Vandenheede, M.; Nicks, B. Comparison of ammonia and greenhouse gas emissions during the fattening of pigs, kept either on fully slatted floor or on deep litter. Livest. Sci. 2007, 111, 144–152. [Google Scholar] [CrossRef]
  30. Jeppsson, K.H. Diurnal variation in ammonia, carbon dioxide and water vapour emission from an uninsulated, deep litter building for growing/finishing pigs. Biosyst. Eng. 2002, 81, 213–224. [Google Scholar] [CrossRef] [Green Version]
  31. Duchaine, C.; Grimard, Y.; Cormier, Y. Influence of building maintenance, environmental factors, and seasons on airborne contaminants of swine confinement buildings. Am. Ind. Hyg. Assoc. J. 2000, 61, 56–63. [Google Scholar] [CrossRef]
  32. Groot Koerkamp, P.W.G.; Metz, J.H.M.; Uenk, G.H.; Phillips, V.R.; Holden, M.R.; Sneath, R.W.; Short, J.L.; Hartung, J.; Seedorf, J.; Schröder, M.; et al. Concentrations and emissions of ammonia in livestock buildings in Northern Europe. J. Agric. Eng. Res. 1998, 70, 79–95. [Google Scholar] [CrossRef]
  33. Choi, H.L.; Kim, K.Y.; Kim, H. Correlation of air pollutants and thermal environment factors in a confined pig house in winter. Asian-Australas. J. Anim. Sci. 2005, 8, 574–579. [Google Scholar]
  34. Pardo, A.; Ruiz, M.Á. Análisis de Datos con SPSS 13 Base; McGraw-Hill/Interamericana de España, SL.: Madrid, Spain, 2005. [Google Scholar]
  35. Pereira, J.; Misselbrook, T.H.; Chadwick, D.R.; Coutinho, J.; Trindade, H. Effects of temperature and dairy cattle excreta characteristics on potential ammonia and greenhouse gas emissions from housing: A laboratory study. Biosyst. Eng. 2012, 112, 138–150. [Google Scholar] [CrossRef]
  36. Sousa, P.; Pedersen, S. Ammonia Emission from Fattening Pig Houses in Relation to Animal Activity and Carbon Dioxide Production. Agric. Eng. Int. CIGR J. 2004, 6, 13. [Google Scholar]
  37. Blanes-Vidal, V.; Hansen, M.N.; Pedersen, S.; Rom, H.B. Emissions of ammonia, methane and nitrous oxide from pig houses and slurry: Effects of rooting material, animal activity and ventilation flow. Agric. Ecosyst. Environ. 2008, 124, 237–244. [Google Scholar] [CrossRef]
Figure 1. View of the room in which measurements were taken and location of sensors for measurements of: (A) carbon dioxide concentration (CO2), ammonia concentration (NH3), relative humidity (RH), temperature (T) and air velocity (VIN) in the animal zone; (B) temperature in the external corridor (TCA) and (C) velocity of the air extracted through the ventilation system (VEX).
Figure 1. View of the room in which measurements were taken and location of sensors for measurements of: (A) carbon dioxide concentration (CO2), ammonia concentration (NH3), relative humidity (RH), temperature (T) and air velocity (VIN) in the animal zone; (B) temperature in the external corridor (TCA) and (C) velocity of the air extracted through the ventilation system (VEX).
Agronomy 11 01927 g001
Figure 2. Evolution of hourly mean values, throughout the measuring period, of NH3 concentration (A), CO2 concentration (B) and temperature of air in external corridor (C) for each setpoint temperature.
Figure 2. Evolution of hourly mean values, throughout the measuring period, of NH3 concentration (A), CO2 concentration (B) and temperature of air in external corridor (C) for each setpoint temperature.
Agronomy 11 01927 g002aAgronomy 11 01927 g002b
Table 1. Correlation matrix based on hourly data for the NH3 with CO2, RH, VIN, VEX, TCA, T for TS 26 ° and 25 °C.
Table 1. Correlation matrix based on hourly data for the NH3 with CO2, RH, VIN, VEX, TCA, T for TS 26 ° and 25 °C.
TSCO2RHVINVEXTCAT
26 °C0.91 **0.78 **0.01−0.72 **−0.80 **0.03
25 °C0.55 **0.16 *−0.35 **−0.65 **−0.29 **−0.08
* p ≤ 0.05. **p ≤ 0.01.
Table 2. Non-standardized coefficients (B), standardized coefficients (β), constants (CTE), correlation coefficients (R), adjusted determination coefficients (R2), standard errors (SE), collinearity statistics (T’ and VIF) and Durbin Watson statistics (DW) for the estimation of NH3 from multiple regressions with the variables: CO2, RH, TCA and VEX for hourly data (H) and TS 26 or 25 °C.
Table 2. Non-standardized coefficients (B), standardized coefficients (β), constants (CTE), correlation coefficients (R), adjusted determination coefficients (R2), standard errors (SE), collinearity statistics (T’ and VIF) and Durbin Watson statistics (DW) for the estimation of NH3 from multiple regressions with the variables: CO2, RH, TCA and VEX for hourly data (H) and TS 26 or 25 °C.
ModelVariableBβCTERR2SET’VIFDW
26H-1CO20.00 **0.91−6.340.910.83 **0.971.001.001.70
26H-2RH0.30 **0.78−13.440.780.60 **1.491.001.001.72
26H-3TCA−0.26 **−0.748.630.800.64 **1.411.001.001.80
26H-4VEX−10.59 **−0.727.960.720.52 **1.631.001.002.01
26H-5CO20.00 **0.711.650.930.86 **0.890.432.341.80
TCA−0.39 **−0.270.432.34
26H-6CO20.00 **0.80−4.150.920.84 **0.940.501.981.70
VEX−2.34 **−0.160.501.98
26H-7TCA−0.74 **−0.505.780.850.71 **1.260.452.281.85
RH0.16 **0.400.452.28
26H-8CO20.00 **0.632.910.870.87 **0.860.333.071.80
TCA−0.36 **−0.250.422.38
VEX−1.92 **−0.130.502.02
25H-1VEX−14.57 ** −0.6512.550.650.42 **1.811.001.001.81
25H-2VEX−11.20 ** −0.504.70 0.710.50 **1.690.78 1.291.90
CO20.00 **0.320.78 1.29
25H-3VEX−10.18 ** −0.495.290.720.51 **1.650.73 1.371.88
CO20.00 **0.310.78 1.29
VIN−58.33 ** −0.160.91 1.11
25H-4VEX−9.80 ** −0.43 0.72 1.401.90
CO20.00 **0.409.860.730.53 **1.630.58 1.74
VIN−62.25 ** −0.17 0.90 1.11
RH−0.11 ** −0.14 0.71 1.40
** p ≤ 0.01.
Table 3. ANOVA test for all models: sum of squares (SS), degree of freedom (df), mean square (MS), F-statistic (F) and p-value (p) for setpoint temperature of 26 and 25 °C for hourly data (H).
Table 3. ANOVA test for all models: sum of squares (SS), degree of freedom (df), mean square (MS), F-statistic (F) and p-value (p) for setpoint temperature of 26 and 25 °C for hourly data (H).
ModelSSdfMSFp
RegressinResidualRegressinResidualRegressinResidual
26H-1495.54101.271107495.540.94523.560.00
26H-2359.90236.911107359.902.21162.540.00
26H-3384.70212.101107384.701.98194.070.00
26H-4311.11285.701107311.112.67116.520.00
26H-5513.5083.312106256.750.79326.660.00
26H-6503.1893.632106251.590.88284.840.00
26H-7428.31168.502106214.151.59134.720.00
26H-8518.5678.253105172.850.75231.940.00
25H-1563.76786.541239563.763.29171.310.00
25H-2670.93679.3652238335.472.85117.520.00
25H-3701.91648.383237233.972.7485.520.00
25H-4720.57629.734236180.152.6767.510.00
Table 4. Non-standardized coefficients (B), standardized coefficients (β), constants (CTE), correlation coefficients (R), adjusted determination coefficients (R2), standard errors (SE), collinearity statistics (T’ and VIF) and Durbin Watson statistics (DW) for the estimation of NH3 from multiple regressions with the variables (V): CO2, RH, TCA and VEX for mean daily data (D) and TS 26 °C or 25 °C.
Table 4. Non-standardized coefficients (B), standardized coefficients (β), constants (CTE), correlation coefficients (R), adjusted determination coefficients (R2), standard errors (SE), collinearity statistics (T’ and VIF) and Durbin Watson statistics (DW) for the estimation of NH3 from multiple regressions with the variables (V): CO2, RH, TCA and VEX for mean daily data (D) and TS 26 °C or 25 °C.
ModelVariableBβCTERR2SET’VIFDW
26D-1CO24 × 10−3 **0.82−7.140.820.66 **0.781.001.001.50
26D-2RH0.37 **0.70−17.340.690.46 **0.991.001.001.55
26D-3TCA−1.12 **−0.8920.300.890.79 **0.621.001.001.56
26D-4VEX−19.78 **−0.7911.850.790.60 **0.871.001.001.86
26D-5CO210−3 *0.3111.700.910.82 **0.580.372.711.74
TCA−0.81 **−0.650.372.71
26D-6CO22 × 10−3 *0.541.040.890.76 **0.660.571.752.32
VEX−10.83 **−0.430.571.75
26D-7RH0.12 *0.2310.570.910.82 **0.580.631.601.78
TCA−0.94 **−0.750.631.60
26D-8RH0.22 **0.41−2.580.870.72 **0.720.771.312.52
VEX−14.81 **−0.600.771.31
26D-9TCA−0.91 **−0.7310.330.910.81 **0.590.382.661.82
VEX−0.60 **−0.020.452.23
RH0.13 *0.240.621.61
25D-1VEX−18.97 **−0.8514.800.850.71 **1.041.001.001.73
25D-2TCA−2.55 **−0.8433.130.840.70 **0.871.001.001.49
25D-3VEX−17.49 **−0.794.880.870.73 **0.820.871.152.02
CO23 × 10−3 *0.180.871.15
25D-4CO26 × 10−3 **0.3713.340.920.83 **0.650.991.021.72
TCA−2.41 **−0.800.991.02
* p ≤ 0.05. ** p ≤ 0.01.
Table 5. ANOVA test for all models: sum of squares (SS), degree of freedom (df), mean square (MS), F-statistic (F) and p-value (p) for setpoint temperature of 26 and 25 °C for mean daily data (D).
Table 5. ANOVA test for all models: sum of squares (SS), degree of freedom (df), mean square (MS), F-statistic (F) and p-value (p) for setpoint temperature of 26 and 25 °C for mean daily data (D).
ModelSSdfMSFp
RegressinResidualRegressinResidualRegressinResidual
26D-128.6513.5412228.650.6246.550.00
26D-220.2321.9512220.230.9920.280.00
26D-333.728.4712233.720.3987.560.00
26D-426.0116.1812226.010.7435.370.00
26D-535.206.9822117.600.3352.930.00
26D-633.099.1022116.550.4338.200.00
26D-735.167.0222117.580.3352.580.00
26D-831.4110.7822115.700.5130.590.00
26D-935.177.0232011.720.3533.410.00
25D-140.9515.7612240.950.7257.160.00
25D-240.4016.3212240.400.7454.470.00
25D-343.0213.7022121.510.6532.980.00
25D-447.049.6722123.520.4651.060.00
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Arango, T.; Besteiro, R.; Ortega, J.A.; Castro, Á.; Rodríguez, M.R.; Fernández, M.D. Linear Models for the Prediction of Animal Zone Ammonia in a Weaned Piglet Building. Agronomy 2021, 11, 1927. https://0-doi-org.brum.beds.ac.uk/10.3390/agronomy11101927

AMA Style

Arango T, Besteiro R, Ortega JA, Castro Á, Rodríguez MR, Fernández MD. Linear Models for the Prediction of Animal Zone Ammonia in a Weaned Piglet Building. Agronomy. 2021; 11(10):1927. https://0-doi-org.brum.beds.ac.uk/10.3390/agronomy11101927

Chicago/Turabian Style

Arango, Tamara, Roberto Besteiro, Juan A. Ortega, Ángel Castro, Manuel Ramiro Rodríguez, and María D. Fernández. 2021. "Linear Models for the Prediction of Animal Zone Ammonia in a Weaned Piglet Building" Agronomy 11, no. 10: 1927. https://0-doi-org.brum.beds.ac.uk/10.3390/agronomy11101927