Next Article in Journal
An Overview of Experiences Made and Tools Used to Inform the Public on Ambient Air Quality
Previous Article in Journal
Changes of Extreme Precipitation and Possible Influence of ENSO Events in a Humid Basin in China
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Reduction in Indoor Airborne Endotoxin Concentration by the Use of Air Purifier and Its Relationship with Respiratory Health: A Randomized Crossover Intervention Study

1
Department of Public Health, Hyogo College of Medicine, Nishinomiya 663-8501, Japan
2
Japan Environment and Children’s Study Programme Office, National Institute for Environmental Studies, Tsukuba 305-8506, Japan
3
Hyogo Regional Centre for Japan Environment and Children’s Study, Hyogo College of Medicine, Nishinomiya 663-8501, Japan
*
Author to whom correspondence should be addressed.
Submission received: 28 September 2021 / Revised: 12 November 2021 / Accepted: 16 November 2021 / Published: 18 November 2021

Abstract

:
Endotoxins are biological components of particulate matter that cause adverse respiratory system effects. Recently, air purifiers have been widely used; however, their effects on endotoxins are not fully understood. We conducted a randomized crossover intervention study to evaluate the effects of air purifiers on indoor endotoxins and occupants’ respiratory health. Thirty-two healthy subjects were randomly assigned to two groups; each group spent four weeks using either a true or sham (filter removed) air purifier. Subsequently, the subjects spent an additional four weeks using the alternative air purifier. The indoor endotoxins in fine (PM2.5) and coarse (PM10–2.5) particulate matter were continuously collected, and pulmonary function was tested repeatedly during the study period. Household characteristics were assessed using a questionnaire. The geometric mean of the PM2.5 endotoxin concentrations was 0.13 EU/m3, which was significantly lower with true purifiers compared with sham purifiers, after adjusting for household characteristics (0.17 EU/m3). In addition, the PM2.5 endotoxin concentrations were significantly greater in reinforced concrete houses than in wooden houses. The PM10–2.5 endotoxin concentrations were significantly greater in homes with two or more household members, and in those with pets. No association was found between endotoxin concentration and respiratory health among the subjects.

1. Introduction

Indoor air pollution is a serious problem. Therefore, air purifiers are widely used to improve indoor air quality. Air purifiers equipped with filters reduce indoor particulate matter (PM) concentrations [1,2,3,4,5]. Air purification has also been reported to benefit cardiovascular health, reduce stress hormone levels, and reduce asthma and allergy symptoms [6,7,8,9]. Endotoxins are lipopolysaccharides from Gram-negative bacteria [10] and are known to cause airway inflammation, which induces the production of cytokines and proteins [11,12]. Endotoxins are suspended as components of airborne PM [13]. Consequently, many studies have been conducted to clarify the effects of endotoxins on human health. Exposure to airborne endotoxins is associated with an increased prevalence of asthma [14] and exacerbation of asthma symptoms [15,16,17,18]. In contrast, an additional study reported that exposure to endotoxins was related to a decreased risk of atopy sensitization, and had a protective effect [19]. Numerous studies have reported exposure to endotoxins in occupational environments, such as in the livestock industry [20,21,22] and textile factories [23,24].
A study in Taiwan reported that the range of indoor airborne endotoxin concentrations was 0.02–8.13 EU/m3 [14]. In Danish homes, the range of indoor endotoxin concentrations was 0.078–8.32 EU/m3 [25]. On the other hand, a study conducted in California found that the range of indoor endotoxin concentrations was 0.063–7.5 EU/m3 [26]. In this way, indoor endotoxin concentrations vary depending on the region and home characteristics. Regarding the aerodynamic diameter of PM, in our previous study [27], the indoor endotoxin concentrations were higher in PM2.5 than in PM10–2.5. The use of air purifiers may effectively reduce indoor PM concentrations [28,29,30,31]. However, the effectiveness of air purifiers on indoor concentrations of endotoxins is not well documented. In our previous observational study, we found that PM2.5 endotoxin concentrations were significantly lower in homes using air purifiers [27]. However, the air purifier model and usage patterns were not specified in the study. In addition, the relationship between the use of an air purifier and the health condition of the occupants was not identified. Currently, the association between indoor endotoxin concentrations and the respiratory systems of healthy subjects is relatively unknown.
Therefore, we performed a crossover intervention study to evaluate the relationship between air purifier usage, indoor endotoxin concentrations in ordinary homes, and the respiratory function of healthy adults residing in those homes. We previously reported the effects of air purifiers on indoor air pollutant concentrations and the respiratory health of occupants in each household [32]. In the present study, we focused on indoor endotoxin concentrations and clarified the effects of endotoxin concentration using an air purifier.

2. Materials and Methods

2.1. Study Design and Subjects

This crossover intervention study was conducted to evaluate the effectiveness of the use of air purifiers for indoor air pollution. The details of this study have been reported in the previous paper showing the relationship between the indoor environment and air purifiers [32]. In summary, the study was conducted between November 2018 and February 2019 in ordinary homes in the Hanshin area of Western Japan (Figure 1). A total of 32 healthy subjects were randomly assigned to one of two groups. All the subjects used the same model of air purifiers. This air purifier is equipped with a dust collection and deodorizing filter, but does not have other functions, such as adsorption, plasma or photocatalytic oxidation. During the study period, the deodorizing function was not used, and only the dust collection function was used. The air flow rate was fixed at 0.5 m3/min during the study period. The airflow of the air purifier was the same with and without the filter, and we consider that there was no difference in air movement in the home and dispersion of PM endotoxins. The air purifier was placed in a living room where the subject spent a lot of time, and the size of the living room was 10 m2 × 36 m2. One group used a true air purifier (EP-NZ30, Hitachi, Tokyo, Japan) and the second group used a sham air purifier that operated with the filter removed. The subjects spent four weeks of the first intervention using one of each air purifier in the living room. Subsequently, both groups spent four weeks of daily life without an air purifier as a washout period. For the next four weeks, each group used the alternate air purifier to the one that was used in the first four weeks. At the study baseline, household characteristics, such as the number of household members and structure of the house, were obtained using a questionnaire. This study adopted a single-blind method. The Ethics Review Board of Hyogo College of Medicine approved the study protocol (registration No. 2898), and all subjects provided written informed consent according to the Declaration of Helsinki. This study protocol was registered in the University Hospital Medical Information Network (UMIN), which is a network organization of 42 national university hospitals nationwide in Japan (number: UMIN000031902).

2.2. Indoor Endotoxin Measurements

The airborne endotoxins were extracted from PM in the indoor air. The airborne PM was collected on a quartz filter weekly using a small vacuum pump (MP-∑300N IIT; Sibata Scientific Technology, Soka, Japan) adjusted to a flow rate of 1.5 L/min. As our previous study showed that endotoxins were detected in both PM2.5 and PM10–2.5 collected from indoor air [27], we used an impactor (ATPS-20H; Sibata Scientific Technology, Soka, Japan) to differentiate the PM into one of the following two categories: the first, PM with a mean aerodynamic diameter less than 2.5 µm (PM2.5), and the second, PM with mean aerodynamic diameter between 2.5 and 10 µm (PM10–2.5). The quartz fiber filters (Whatman Inc., Florham Partk, NJ) used for the collection were sterilized by dry heat at 250 °C for 2 h prior to use and stored at −30 °C until analysis. We analyzed endotoxins using the kinetic Limulus amebocyte lysate assay (Pyrostar ES-F test, Wako Pure Chemical Industries, Ltd., Osaka, Japan). This procedure involved the use of a toxinometer (ET-6000, Wako Pure Chemical Industries, Ltd., Osaka, Japan) in our previous study [27]. Blank filters were used during each intervention period. The endotoxin concentrations were expressed in endotoxin units (EU/m3) per cubic meter of collected air. The detection limit was 0.001 EU/mL, which corresponded to a 0.0022 EU/filter.
We also measured the mass concentrations of PM2.5 and PM10–2.5, to evaluate endotoxin concentrations per milligram of PM2.5 and PM10–2.5. We collected PM2.5 and PM10–2.5 on a Teflon-coated glass fiber filter with the same methods as endotoxin, and measured them using an electronic microbalance with a sensitivity of 0.1 µg (UMX-2, Mettler-Toledo Inc., Columbus, OH, USA). The temperature and humidity in homes were measured using a HOBO data logger (Onset Computer Corp., Bourne, MA, USA). Data were recovered from the data loggers at the end of each intervention period. The average value for each week was then calculated.

2.3. Spirometry and Exhaled Nitric Oxide Measurements

Pulmonary function and fractional exhaled nitric oxide (FeNO) levels were measured weekly when the subjects arrived at the laboratory to replace the endotoxin collection pump. Pulmonary function tests were conducted using a spirometer (Microspiro HI-205T. Chest, M.I., Inc., Tokyo, Japan), which was calibrated to a volume of 3 L using a syringe. Forced vital capacity (FVC), forced expiratory volume in one second (FEV1.0), FEV1.0/FVC, maximal mid-expiratory flow (MMEF), peak expiratory flow rate (PEF), and the ratio of the maximum expiratory flow rate at 50% of the FVC to the maximum expiratory flow rate at 25% of the FVC ( V ˙ 50/ V ˙ 25) were used as the parameters to quantify pulmonary function.
We also measured FeNO, which is a biomarker of airway inflammation [33,34,35], using NObreath (Bedfont Scientific, Maidstone, UK). The measuring instrument was calibrated to zero monthly according to the manufacturer’s specifications. This instrument is designed to operate in environments containing NO concentrations less than 350 ppb NO; consequently, FeNO measurements were conducted after measuring the concentration of NO in the indoor air in the laboratory.
These tests were performed by qualified inspectors in accordance with the American Thoracic Society guidelines [36,37,38].

2.4. Statistical Analysis

Because the data for endotoxins, PM concentrations, and FeNO were roughly lognormally distributed, the values were converted to common logarithms for statistical analysis. The log-transformed data were confirmed to be normally distributed by Kolmogorov–Smirnov test. Endotoxin and PM concentrations were expressed as geometric means with 95% confidence intervals (CIs). Characteristics of the subjects and parameters of pulmonary function were calculated as arithmetic mean ± standard deviation. The endotoxin concentrations per milligram of PM2.5 and PM10–2.5 were expressed as EU/mg. The t-test was used to compare differences in indoor endotoxin concentrations between the true and sham air purifiers. Mixed-effects models with a compound symmetry covariance structure were used to quantify the relationship between endotoxin concentrations and household characteristics. We considered and analyzed the use of air purifiers, household members, the presence of pets, the structure of the house, architectural style, floor type, temperature, and humidity as fixed effects. The relationships between endotoxin concentrations in homes and the respiratory function parameters were analyzed using a mixed-effects model with unstructured covariance matrix, which is suitable for repeated measures, to evaluate endotoxin concentration measurements for the week prior to a pulmonary function test. This analysis was adjusted for age, sex, body mass index, intervention period, temperature, and humidity.
SPSS 22 software (IBM Co., Armonk, NY, USA) was used for all analyses. Statistical significance was assessed using a p-value of <0.05.

3. Results

For one of the 32 subjects, the endotoxin concentrations could not be measured because the pump had multiple errors at all times. Consequently, 31 participants completed the study. There were 9 men and 22 women, with ages ranging from 31 to 60 years. The average age was 41.1 ± 7.6 years, and the average body mass index (BMI) was 21.8 ± 3.2 kg/m2 (Table 1). For the household characteristics of the subjects, according to the questionnaire, ten subjects lived alone and five kept pets.
A total of 248 endotoxin samples were collected for PM2.5 and PM10–2.5. These samples were from 31 homes, each of which received weekly sampling during the study period. Of the collected filters, 14 samples in PM2.5 and 11 samples in PM10–2.5 were excluded from the analysis because of pump errors or filter contamination. Endotoxin concentrations were not detected in any of the blank filters. The geometric mean of the PM2.5 endotoxin concentrations was 0.13 EU/m3 for the true air purifiers. This value was significantly less than the corresponding value, 0.17 EU/m3, for the sham air purifiers (p = 0.002, Table 2). In contrast, the PM10–2.5 endotoxin concentrations decreased slightly during the use of the true air purifier; however, the difference was not significant. Similarly, the PM2.5 mass concentrations when using the true air purifier were significantly less than the same while using the sham air purifier; however, there were no differences observed for the PM10–2.5 mass concentrations. For the endotoxin concentrations per milligram of particulate matter, both the PM2.5 and PM10–2.5 endotoxin concentrations decreased slightly while using the true air purifier, but no significant difference was found.
Table 3 presents the relative percentage change in endotoxin concentrations, corresponding to differences in household characteristics and meteorological factors. The PM2.5 endotoxin concentrations during the use of the true air purifier were significantly less than those observed while using the sham air purifier (−14.0% (95% CI: −18.8, −9.3). Regarding the structure of the house, the PM2.5 endotoxin concentrations were significantly higher in reinforced concrete houses than in wooden houses (34.1% (95% CI: 6.9, 61.2)). The PM10–2.5 endotoxin concentrations were slightly lower with the use of the true air purifier, but no significant difference was observed. The PM10–2.5 endotoxin concentrations were also significantly lower in single-person households than in houses with two or more household members. In addition, the PM10–2.5 endotoxin concentrations were significantly higher in homes with pets than in those without pets. Neither the PM2.5 nor PM10–2.5 endotoxin concentrations were observed to be related to indoor temperature and humidity during the intervention period.
The results of pulmonary function and FeNO measurements are shown in Table 4. The FeNO levels were higher in males than in females during both intervention periods. For the parameters of pulmonary function, V ˙ 50/ V ˙ 25 was higher in females than in males during both intervention periods, but all the other parameters were higher in males (Table 4).
Table 5 presents the correlations between endotoxin concentrations, changes in pulmonary function parameters, and FeNO levels. The FVC decreased slightly when the PM2.5 and PM10–2.5 endotoxin concentrations increased (−0.02 (95% CI: −0.11, 0.07), −0.02 (95% CI: −0.07, 0.04) per increase of 1 log endotoxin (EU/m3), respectively). However, the difference was not statistically significant. Similarly, FEV1.0, V ˙ 50/ V ˙ 25, and FeNO decreased slightly with an increase in the PM2.5 and PM10–2.5 endotoxin concentrations; however, a significant difference was not found. In addition, FEV1.0/FVC and MMEF showed a slight increase when subjected to an increase for each endotoxin concentration, but the difference was not statistically significant. Consequently, the endotoxin concentrations in indoor PM2.5 and PM10–2.5 did not show any statistically significant differences in pulmonary function and FeNO levels.

4. Discussion

This study aimed to evaluate the reduction in indoor endotoxin concentrations in ordinary homes using an air purifier, and the effect of endotoxins on the respiratory functions of occupants therein. The results indicated that the PM2.5 and PM10–2.5 endotoxin concentrations decreased when an air purifier was used. This reduction was statistically significant for the PM2.5 endotoxin concentrations. However, no significant relationship was found between endotoxin concentrations, pulmonary function, and FeNO concentration among the occupants.
Several studies have demonstrated that endotoxin concentrations depend on suspended particle diameter [39,40]. In our previous study, the PM2.5 endotoxin concentrations in homes were greater than the PM10–2.5 endotoxin concentrations [27]. This is consistent with the results of the present study. Padhi et al. also reported that the PM2.5 endotoxin concentrations in homes were higher than the PM10 endotoxin concentrations [41]. Our study showed that the use of an air purifier reduced the endotoxin concentrations for both the PM2.5 and PM10–2.5 components; however, the difference was only significant for the PM2.5 component. This finding may indicate that endotoxin concentrations and air purifier effects depend on particle size.
We observed that the PM2.5 endotoxin concentrations decreased significantly with the use of an air purifier. Although the difference was as small as 0.04 EU/m3, it was shown that the PM2.5 endotoxin concentrations, which had been considerably low in the home, were further reduced by using an air purifier. This result is compatible with our previous observational study, in which the PM2.5 endotoxin concentrations decreased with the use of an air purifier; however, there was no significant effect of air purifier usage on PM10–2.5 endotoxin concentrations. In contrast, Niu et al. reported that endotoxin concentrations varied prior to and after filter cleaning, and that filter replacement may reduce the increase in endotoxins of large sizes, but not smaller sizes [42]. From these results, the relationship between endotoxin concentrations and the use of an air purifier has not been consistently found; consequently, additional studies are needed to clarify this relationship.
In the present study, the PM2.5 endotoxin concentrations were greater in reinforced concrete houses than in wooden houses. Tran et al. reported that endotoxin concentrations depend on the material comprising houses in Ho Chi Minh City, Vietnam [43]. This suggests that the structure of the house may affect the endotoxin concentrations. Presumably, the difference in endotoxin concentrations, which depend on the structure of the house, was attributed to the absence of air exchange between the indoor and outdoor environment. Regarding household members, the PM10–2.5 endotoxin concentrations were significantly less in single-person households. This result is similar to that of our previous study [27], in which the PM10–2.5 endotoxin concentrations were significantly greater in homes with two or more children. These results suggest that PM10–2.5 endotoxin concentrations are related to human activity. In a previous study [27], the PM2.5 endotoxin concentrations were significantly greater in homes with pets, but for the PM10–2.5 endotoxin concentrations, this effect was not significant. Conversely, the present results indicated that the PM10–2.5 endotoxin concentrations were significantly greater in homes with pets, even when considering the use of an air purifier. Several studies have investigated the presence of pets as an endotoxin source [44,45]. This is consistent with this study’s results.
Endotoxins have been reported to cause adverse effects in the respiratory system. However, the present study found no relationship between endotoxin concentration and the subject’s respiratory system. Rooij et al. noted that increasing endotoxin levels emitted from livestock farmers caused the prevalence of respiratory symptoms in neighboring populations; however, the endotoxin levels were not significantly associated with lung function [22]. Nonnenmann et al. observed no association between exposure to endotoxins via personal inhalation, lung function, and FeNO among dairy workers [21]. Our results concur with these results. High personal endotoxin exposure levels have been reported to decrease FEV1 among children with asthma [46]. As children are known to be more susceptible to air pollution than adults [47], they may also be more sensitive to endotoxin exposure. However, healthy adults may be less susceptible to infection. The reason for no effect being observed may be that the endotoxin concentrations in this study were considerably lower than those in the previous study. The low concentrations are observed regardless of the use of the true or sham air purifier. Recent studies have shown that indoor endotoxin concentrations are not associated with lung function in schoolchildren; however, indoor O3 and PM10 concentrations alter the association between airborne endotoxin and lung function in schoolchildren [48]. This finding may indicate that the interaction between airborne endotoxins and air pollutants affects the lung function of children, so it is necessary to analyze not only the endotoxin concentrations, but also the other air pollutants present in indoor environments.
The limitations of this study are as follows: Firstly, the sample size was relatively small. If the number of samples was larger, the statistical detection would increase. However, such an intervention study would be expensive and effort intensive, as it would require preparing air purifiers, setting up environmental measuring instruments, and measuring pulmonary function. Secondly, we measured the endotoxin concentrations once a week for a total of two months during the winter season. As airborne endotoxin concentrations vary seasonally [49], further study should be conducted throughout the year. Thirdly, because the size of the living room where the air purifier was installed was different in each home, the effectiveness of air purification also varied. However, it is impossible to prepare a space with the same conditions when conducting an intervention study for ordinary households. By contrast, a positive attribute of this study is that the subjects were healthy adults. Furthermore, because we repeated the endotoxin measurement and the respiratory function test, we could accurately evaluate the relationship between the effect of the air purifier and respiratory function. Therefore, we believe that the results of this study can be generalized.

5. Conclusions

Recently, the use of air purifiers in ordinary homes has increased. The use of an air purifier is effective for reducing indoor air pollutants in the living rooms or bedrooms where people generally reside. Our results showed that the indoor endotoxin concentrations were not very large, but the use of an air purifier further reduced the indoor endotoxin concentrations. However, the respiratory function of the subjects remained unaffected when using an air purifier.

Author Contributions

Conceptualization, Y.Y. and M.S.; methodology, Y.Y. and M.S.; software, Y.Y.; validation, Y.Y. and K.T.; formal analysis, Y.Y. and M.S.; investigation, Y.Y. and K.T.; resources, S.F.N. and K.T.; data curation, Y.Y. and M.S.; writing—original draft preparation, Y.Y. and M.S.; writing—review and editing, Y.Y., N.O., H.H. and M.S.; visualization, Y.Y.; supervision, M.S. and S.F.N.; project administration, Y.Y. and M.S.; funding acquisition, Y.Y. and M.S. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by JSPS KAKENHI (grant number: JP17K09169).

Institutional Review Board Statement

The study was conducted according to the guidelines of the Declaration of Helsinki, and approved by the Ethics Review Board of Hyogo College of Medicine (Registered No. 2898).

Informed Consent Statement

Informed consent was obtained from all the subjects involved in the study.

Data Availability Statement

The data set is available from the corresponding author, upon reasonable request.

Acknowledgments

The authors would like to thank all the participants for their time and effort to participate in this study.

Conflicts of Interest

The authors declare no conflict of interest.

Abbreviations

PMparticulate matter
PM2.5fine particulate matter ≤2.5 µm in aerodynamic diameter
PM10–2.5coarse particulate matter between 2.5 and 10 µm in aerodynamic diameter
FEV1.0forced expiratory volume in one second
FVCforced vital capacity
MMEFmaximal mid-expiratory flow
PEFpeak expiratory flow rate
V ˙ 50 / V ˙ 25the ratio of the maximum expiratory flow rate at 50% of the FVC to the maximum expiratory flow rate at 25% of the FVC
FeNOfractional exhaled nitric oxide
GMgeometric mean
SDstandard deviation
BMIbody mass index
CIconfidence interval

References

  1. Reisman, R.E.; Mauriello, P.M.; Davis, G.B.; Georgitis, J.W.; DeMasi, J.M. A double-blind study of the effectiveness of a high-efficiency particulate air (HEPA) filter in the treatment of patients with perennial allergic rhinitis and asthma. J. Allergy Clin. Immunol. 1990, 85, 1050–1057. [Google Scholar] [CrossRef]
  2. Cui, X.; Li, Z.; Teng, Y.; Barkjohn, K.J.; Norris, C.L.; Fang, L.; Daniel, G.N.; He, L.; Lin, L.; Wang, Q.; et al. Association Between Bedroom Particulate Matter Filtration and Changes in Airway Pathophysiology in Children with Asthma. JAMA Pediatr. 2020, 174, 533–542. [Google Scholar] [CrossRef] [PubMed]
  3. Du, L.; Batterman, S.; Parker, E.; Godwin, C.; Chin, J.-Y.; O’Toole, A.; Robins, T.; Brakefield-Caldwell, W.; Lewis, T. Particle concentrations and effectiveness of free-standing air filters in bedrooms of children with asthma in Detroit, Michigan. Build. Environ. 2011, 46, 2303–2313. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  4. Batterman, S.; Godwin, C.; Jia, C. Long Duration Tests of Room Air Filters in Cigarette Smokers’ Homes. Environ. Sci. Technol. 2005, 39, 7260–7268. [Google Scholar] [CrossRef] [PubMed]
  5. Ciuzas, D. Indoor Air Quality Management by Combined Ventilation and Air Cleaning: An Experimental Study. Aerosol Air Qual. Res. 2016, 16, 2550–2559. [Google Scholar] [CrossRef] [Green Version]
  6. Liu, S.; Chen, J.; Zhao, Q.; Song, X.; Shao, D.; Meliefste, K.; Du, Y.; Wang, J.; Wang, M.; Wang, T.; et al. Cardiovascular benefits of short-term indoor air filtration intervention in elderly living in Beijing: An extended analysis of BIAPSY study. Environ. Res. 2018, 167, 632–638. [Google Scholar] [CrossRef]
  7. Li, H.; Cai, J.; Chen, R.; Zhao, Z.; Ying, Z.; Wang, L.; Chen, J.; Hao, K.; Kinney, P.L.; Chen, H.; et al. Particulate matter exposure and stress hormone levels: A randomized, double-blind, crossover trial of air purification. Circulation 2017, 136, 618–627. [Google Scholar] [CrossRef]
  8. Jia-Ying, L.; Zhao, C.; Jia-Jun, G.; Zi-Jun, G.; Xiao, L.; Bao-Qing, S. Efficacy of air purifier therapy in allergic rhinitis. Asian Pac. J. Allergy Immunol. 2018, 36, 217–221. [Google Scholar] [CrossRef]
  9. James, C.; Bernstein, D.I.; Cox, J.; Ryan, P.; Wolfe, C.; Jandarov, R.; Newman, N.; Indugula, R.; Reponen, T. HEPA filtration improves asthma control in children exposed to traffic-related airborne particles. Indoor Air 2020, 30, 235–243. [Google Scholar] [CrossRef]
  10. Ulevitch, R.J.; Tobias, P.S. Receptor-Dependent Mechanisms of Cell Stimulation by Bacterial Endotoxin. Annu. Rev. Immunol. 1995, 13, 437–457. [Google Scholar] [CrossRef]
  11. Thorne, P.S. Inhalation toxicology models of endotoxin- and bioaerosol-induced inflammation. Toxicology 2000, 152, 13–23. [Google Scholar] [CrossRef]
  12. Poole, J.A.; Romberger, D.J. Immunological and inflammatory responses to organic dust in agriculture. Curr. Opin. Allergy Clin. Immunol. 2012, 12, 126–132. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  13. Walters, M.; Milton, D.; Larsson, L.; Ford, T. Airborne environmental endotoxin: A cross-validation of sampling and analysis techniques. Appl. Environ. Microbiol. 1994, 60, 996–1005. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  14. Yen, Y.-C.; Yang, C.-Y.; Wang, T.-N.; Yen, P.-C.; Ho, C.-K.; Mena, K.D.; Lee, T.-C.; Chen, K.-S.; Lin, Y.-C.; Chen, P.-S. Household airborne endotoxin associated with asthma and allergy in elementary school-age children: A case–control study in Kaohsiung, Taiwan. Environ. Sci. Pollut. Res. 2020, 27, 19502–19509. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  15. Kljaic-Bukvic, B.; Blekic, M.; Aberle, N.; Curtin, J.A.; Hankinson, J.; Semic-Jusufagic, A.; Belgrave, D.; Simpson, A.; Custovic, A. Genetic variants in endotoxin signalling pathway, domestic endotoxin exposure and asthma exacerbations. Pediatr. Allergy Immunol. 2014, 25, 552–557. [Google Scholar] [CrossRef]
  16. Khan, M.S.; Coulibaly, S.; Matsumoto, T.; Yano, Y.; Miura, M.; Nagasaka, Y.; Shima, M.; Yamagishi, N.; Wakabayashi, K.; Watanabe, T. Association of airborne particles, protein, and endotoxin with emergency department visits for asthma in Kyoto, Japan. Environ. Health Prev. Med. 2018, 23, 41. [Google Scholar] [CrossRef]
  17. Lai, P.S.; Sheehan, W.J.; Gaffin, J.M.; Petty, C.R.; Coull, B.A.; Gold, D.R.; Phipatanakul, W. School Endotoxin Exposure and Asthma Morbidity in Inner-city Children. Chest 2015, 148, 1251–1258. [Google Scholar] [CrossRef] [Green Version]
  18. Park, J.-H.; Gold, D.R.; Spiegelman, D.L.; Burge, H.A.; Milton, D.K. House Dust Endotoxin and Wheeze in the First Year of Life. Am. J. Respir. Crit. Care Med. 2001, 163, 322–328. [Google Scholar] [CrossRef]
  19. Smit, L.A.; Heederik, D.; Doekes, G.; Lammers, J.-W.J.; Wouters, I.M. Occupational Endotoxin Exposure Reduces the Risk of Atopic Sensitization but Increases the Risk of Bronchial Hyperresponsiveness. Int. Arch. Allergy Immunol. 2010, 152, 151–158. [Google Scholar] [CrossRef]
  20. O’Shaughnessy, P.; Peters, T.; Donham, K.; Taylor, C.; Altmaier, R.; Kelly, K. Assessment of Swine Worker Exposures to Dust and Endotoxin during Hog Load-Out and Power Washing. Ann. Occup. Hyg. 2012, 56, 843–851. [Google Scholar] [CrossRef] [Green Version]
  21. Nonnenmann, M.W.; de Porras, D.G.R.; Levin, J.; Douphrate, D.; Boggaram, V.; Schaeffer, J.; Ms, M.G.; Ms, M.H.; Reynolds, S. Pulmonary function and airway inflammation among dairy parlor workers after exposure to inhalable aerosols. Am. J. Ind. Med. 2017, 60, 255–263. [Google Scholar] [CrossRef] [PubMed]
  22. de Rooij, M.M.T.; Smit, L.A.M.; Erbrink, H.J.; Hagenaars, T.J.; Hoek, G.; Ogink, N.; Winkel, A.; Heederik, D.J.; Wouters, I. Endotoxin and particulate matter emitted by livestock farms and respiratory health effects in neighboring residents. Environ. Int. 2019, 132, 105009. [Google Scholar] [CrossRef] [PubMed]
  23. Ghani, N.; Khalid, A.; Tahir, A. Cross-sectional study on the endotoxin exposure and lung function impairment in the workers of textile industry near Lahore, Pakistan. J. Pak. Med. Assoc. 2016, 66, 803–814. [Google Scholar] [PubMed]
  24. Paudyal, P.; Semple, S.; Gairhe, S.; Steiner, M.F.; Niven, R.; Ayres, J.G. Respiratory symptoms and cross-shift lung function in relation to cotton dust and endotoxin exposure in textile workers in Nepal: A cross-sectional study. Occup. Environ. Med. 2015, 72, 870–876. [Google Scholar] [CrossRef] [Green Version]
  25. Frankel, M.; Bekö, G.; Timm, M.; Gustavsen, S.; Hansen, E.W.; Madsen, A.M. Seasonal Variations of Indoor Microbial Exposures and Their Relation to Temperature, Relative Humidity, and Air Exchange Rate. Appl. Environ. Microbiol. 2012, 78, 8289–8297. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  26. Delfino, R.J.; Staimer, N.; Tjoa, T. Personal endotoxin exposure in a panel study of school children with asthma. Environ. Health 2011, 10, 69. [Google Scholar] [CrossRef] [Green Version]
  27. Yoda, Y.; Tamura, K.; Shima, M. Airborne endotoxin concentrations in indoor and outdoor particulate matter and their predictors in an urban city. Indoor Air 2017, 27, 955–964. [Google Scholar] [CrossRef] [Green Version]
  28. Wheeler, A.J.; Gibson, M.D.; MacNeill, M.; Ward, T.J.; Wallace, L.A.; Kuchta, J.; Seaboyer, M.; Dabek-Zlotorzynska, E.; Guernsey, J.R.; Stieb, D.M. Impacts of Air Cleaners on Indoor Air Quality in Residences Impacted by Wood Smoke. Environ. Sci. Technol. 2014, 48, 12157–12163. [Google Scholar] [CrossRef]
  29. Ma, H.; Shen, H.; Shui, T.; Li, Q.; Zhou, L. Experimental Study on Ultrafine Particle Removal Performance of Portable Air Cleaners with Different Filters in an Office Room. Int. J. Environ. Res. Public Health 2016, 13, 102. [Google Scholar] [CrossRef] [Green Version]
  30. Fermo, P.; Comite, V.; Falciola, L.; Guglielmi, V.; Miani, A. Efficiency of an Air Cleaner Device in Reducing Aerosol Particulate Matter (PM) in Indoor Environments. Int. J. Environ. Res. Public Health 2019, 17, 18. [Google Scholar] [CrossRef] [Green Version]
  31. Park, J.-H.; Lee, T.J.; Park, M.J.; Oh, H.N.; Jo, Y.M. Effects of air cleaners and school characteristics on classroom concentrations of particulate matter in 34 elementary schools in Korea. Build. Environ. 2020, 167, 106437. [Google Scholar] [CrossRef] [PubMed]
  32. Yoda, Y.; Tamura, K.; Adachi, S.; Otani, N.; Nakayama, S.F.; Shima, M. Effects of the Use of Air Purifier on Indoor Environment and Respiratory System among Healthy Adults. Int. J. Environ. Res. Public Health 2020, 17, 3687. [Google Scholar] [CrossRef] [PubMed]
  33. Barnes, P.J.; Belvisi, M.G. Nitric oxide and lung disease. Thorax 1993, 48, 1034–1043. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  34. Maziak, W.; Loukides, S.; Culpitt, S.; Sullivan, P.; Kharitonov, S.A.; Barnes, P.J. Exhaled Nitric Oxide in Chronic Obstructive Pulmonary Disease. Am. J. Respir. Crit. Care Med. 1998, 157, 998–1002. [Google Scholar] [CrossRef] [Green Version]
  35. Clini, E.; Bianchi, L.; Pagani, M.; Ambrosino, N. Endogenous nitric oxide in patients with stable COPD: Correlates with severity of disease. Thorax 1998, 53, 881–883. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  36. Miller, M.R.; Crapo, R.; Hankinson, J.; Brusasco, V.; Burgos, F.; Casaburi, R.; Coates, A.; Enright, P.; van der Grinten, C.P.M.; Gustafsson, P.; et al. General considerations for lung function testing. Eur. Respir. J. 2005, 26, 153–161. [Google Scholar] [CrossRef] [Green Version]
  37. American Thoracic Society; European Respiratory Society. ATS/ERS Recommendations for Standardized Procedures for the Online and Offline Measurement of Exhaled Lower Respiratory Nitric Oxide and Nasal Nitric Oxide, 2005. Am. J. Respir. Crit. Care Med. 2005, 171, 912–930. [Google Scholar] [CrossRef]
  38. Dweik, R.A.; Boggs, P.B.; Erzurum, S.C.; Irvin, C.G.; Leigh, M.W.; Lundberg, J.O.; Olin, A.-C.; Plummer, A.L.; Taylor, D.R. An Official ATS Clinical Practice Guideline: Interpretation of Exhaled Nitric Oxide Levels (FeNO) for Clinical Applications. Am. J. Respir. Crit. Care Med. 2011, 184, 602–615. [Google Scholar] [CrossRef] [Green Version]
  39. Heinrich, J.; Pitz, M.; Bischof, W.; Krug, N.; Borm, P.J.A. Endotoxin in fine (PM2.5) and coarse (PM2.5–10) particle mass of ambient aerosols. A temporo-spatial analysis. Atmos. Environ. 2003, 37, 3659–3667. [Google Scholar] [CrossRef]
  40. Monn, C.; Becker, S. Cytotoxicity and Induction of Proinflammatory Cytokines from Human Monocytes Exposed to Fine (PM2.5) and Coarse Particles (PM10–2.5) in Outdoor and Indoor Air. Toxicol. Appl. Pharmacol. 1999, 155, 245–252. [Google Scholar] [CrossRef]
  41. Padhi, B.K.; Adhikari, A.; Satapathy, P.; Patra, A.K.; Chandel, D.; Panigrahi, P. Predictors and respiratory depositions of airborne endotoxin in homes using biomass fuels and LPG gas for cooking. J. Expo. Sci. Environ. Epidemiol. 2016, 27, 112–117. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  42. Niu, M.; Shen, F.; Zhou, F.; Zhu, T.; Zheng, Y.; Yang, Y.; Sun, Y.; Li, X.; Wu, Y.; Fu, P.; et al. Indoor air filtration could lead to increased airborne endotoxin levels. Environ. Int. 2020, 142, 105878. [Google Scholar] [CrossRef]
  43. Tran, T.N.; Tran, T.T.T.; Nguyen, D.K.T.; Doyen, V.; Michel, O.; Bouland, C. An unequal endotoxin distribution in typical house types of Ho Chi Minh city. Asian Pac. J. Allergy Immunol. 2020. [Google Scholar] [CrossRef]
  44. Thorne, P.S.; Cohn, R.D.; Mav, D.; Arbes, S.J.; Zeldin, D.C. Predictors of Endotoxin Levels in U.S. Housing. Environ. Health Perspect. 2009, 117, 763–771. [Google Scholar] [CrossRef] [PubMed]
  45. Mendy, A.; Wilkerson, J.; Salo, P.M.; Cohn, R.D.; Zeldin, D.; Thorne, P.S. Exposure and Sensitization to Pets Modify Endotoxin Association with Asthma and Wheeze. J. Allergy Clin. Immunol. Pract. 2018, 6, 2006–2013. [Google Scholar] [CrossRef]
  46. Rabinovitch, N.; Liu, A.H.; Zhang, L.; Rodes, C.E.; Foarde, K.; Dutton, S.J.; Murphy, J.R.; Gelfand, E.W. Importance of the personal endotoxin cloud in school-age children with asthma. J. Allergy Clin. Immunol. 2005, 116, 1053–1057. [Google Scholar] [CrossRef] [PubMed]
  47. Hoek, G.; Pattenden, S.; Willers, S.; Antova, T.; Fabianova, E.; Braun-Fahrländer, C.; Forastiere, F.; Gehring, U.; Luttmann-Gibson, H.; Grize, L.; et al. PM10, and children’s respiratory symptoms and lung function in the PATY study. Eur. Respir. J. 2012, 40, 538–547. [Google Scholar] [CrossRef] [Green Version]
  48. Yen, Y.-C.; Yang, C.-Y.; Ho, C.-K.; Yen, P.-C.; Cheng, Y.-T.; Mena, K.D.; Lee, T.-C.; Chen, P.-S. Indoor ozone and particulate matter modify the association between airborne endotoxin and schoolchildren’s lung function. Sci. Total. Environ. 2020, 705, 135810. [Google Scholar] [CrossRef]
  49. Hwang, S.H.; Park, D.J.; Park, W.M.; Ahn, J.K.; Yoon, C.S.; Park, D.U. Seasonal variation in airborne endotoxin levels in indoor environments with different micro-environmental factors in Seoul, South Korea. Environ. Res. 2016, 145, 101–108. [Google Scholar] [CrossRef]
Figure 1. Location of Hanshin area in Japan. The map was obtained from the internet (https://nureyon.com/japanese_archipelago-1?pattern=12 (accessed on 27 September 2021)).
Figure 1. Location of Hanshin area in Japan. The map was obtained from the internet (https://nureyon.com/japanese_archipelago-1?pattern=12 (accessed on 27 September 2021)).
Atmosphere 12 01523 g001
Table 1. Study subject characteristics.
Table 1. Study subject characteristics.
Characteristics(n = 31)
Sex
male9
female22
Age (years)
mean ± SD41.1 ± 7.6
range31–60
BMI (kg/m2)
mean ± SD21.8 ± 3.2
range16.6–31.6
Household members
One10
Two or more21
Presence of pet
Yes5
No26
Structure of house
Reinforced concrete25
Wood6
Architectural style
Apartment21
Detached house10
Type of floor
Wooden flooring21
Others10
SD, standard deviation; BMI, body mass index.
Table 2. Comparison of measurement results of each concentration using the true and sham air purifiers.
Table 2. Comparison of measurement results of each concentration using the true and sham air purifiers.
True Air PurifiersSham Air Purifiers
nGM (95% CI)nGM (95% CI)p
Endotoxin (EU/m3) data data
PM2.51150.13 (0.12, 0.15)1190.17 (0.15, 0.19)0.002
PM10–2.51180.09 (0.07, 0.10)1190.10 (0.09, 0.12)0.297
Endotoxin (EU/mg PM)
PM2.510918.5 (16.7, 20.4)11719.1 (17.2, 21.1)0.663
PM10–2.511044.2 (37.6, 51.8)11646.8 (39.6, 55.4)0.619
GM, geometric mean; CI, confidence interval; p, p-value.
Table 3. The percent changes in endotoxin concentrations related to household characteristics and meteorological factors.
Table 3. The percent changes in endotoxin concentrations related to household characteristics and meteorological factors.
PM2.5 EndotoxinPM10−2.5 Endotoxin
Percent Change (95%CI)pPercent Change (95%CI)p
Air purifier (true/sham)−14.0 (−18.8, −9.3)<0.001−3.8 (−9.4, 1.7)0.177
Household members
(one/two or more)
−2.8 (−20.7, 15.0)0.748−29.2 (−52.2, −6.1)0.015
Presence of pet (yes/no)6.4 (−19.1, 31.8)0.61141.6 (12.4, 70.7)0.007
Structure of house
(reinforced concrete/wood)
34.1 (6.9, 61.2)0.0161.6 (−31.6, 34.9)0.920
Architectural style (apartment/house)−12.9 (−40.6, 14.8)0.34814.4 (−19.8, 48.6)0.395
Type of floor
(others/wooden flooring)
−4.4 (−20.1, 11.4)0.5766.9 (−11.7, 25.6)0.453
Temperature (°C)0.7 (−0.9, 2.2)0.394−0.3 (−2.1, 1.5)0.759
Relative humidity (%)0.3 (−0.2, 0.9)0.1900.4 (−0.2, 1.0)0.188
CI, confidence interval; p, p-value.
Table 4. Summary of pulmonary function and exhaled nitric oxide measurement (mean ± SD).
Table 4. Summary of pulmonary function and exhaled nitric oxide measurement (mean ± SD).
1st Term2nd Term
MaleFemaleMaleFemale
FVC (L)3.79 ± 0.383.02 ± 0.343.85 ± 0.433.01 ± 0.33
FEV1.0 (L)3.17 ± 0.442.46 ± 0.293.21 ± 0.432.45 ± 0.29
FEV1.0/FVC (%)83.4 ± 6.082.0 ± 7.183.3 ± 4.881.6 ± 7.0
MMEF (L/s)3.43 ± 1.012.71 ± 0.803.52 ± 1.032.73 ± 0.88
PEF (L/s)7.95 ± 2.565.13 ± 1.228.72 ± 2.155.29 ± 1.19
V ˙ 50/ V ˙ 252.75 ± 0.893.70 ± 2.982.82 ± 0.893.48 ± 1.26
FeNO (ppb) *13.0 ± 2.510.3 ± 2.114.5 ± 2.510.6 ± 2.6
* Geometric mean. SD, standard deviation; FEV1.0, forced expiratory volume in one second; FVC, forced vital capacity; FEV1.0/FVC, forced expiratory volume in one second/forced vital capacity; MMEF, maximal mid-expiratory flow; PEF, peak expiratory flow rate; V ˙ 50/ V ˙ 25, maximal expiratory flow rate at 50%/25% of the average vital capacity; FeNO, fractional exhaled nitric oxide.
Table 5. Associations between PM2.5 and PM10–2.5 endotoxin concentrations, changes in pulmonary function parameters, and FeNO concentration levels.
Table 5. Associations between PM2.5 and PM10–2.5 endotoxin concentrations, changes in pulmonary function parameters, and FeNO concentration levels.
PM2.5 EndotoxinPM10−2.5 Endotoxin
Percent Change (95%CI)pPercent Change (95%CI)p
FVC (L)−0.02 (−0.11, 0.07)0.671−0.02 (−0.07, 0.04)0.509
FEV1.0 (L)−0.04 (−0.11, 0.03)0.297−0.01 (−0.06, 0.03)0.607
FEV1.0/FVC (%)1.58 (−0.45, 3.16)0.1270.16 (−1.05, 1.38)0.788
MMEF (L/s)0.12 (−0.12, 0.35)0.3250.01 (−0.13, 0.16)0.840
PEF (L/s)0.27 (−0.25, 0.79)0.307−0.21 (−0.58, 0.16)0.263
V ˙ 50/ V ˙ 25−0.16 (−0.64, 0.32)0.516−0.24 (−0.51, 0.03)0.078
LogFeNO−0.12 (−0.27, 0.03)0.123−0.07 (−0.19, 0.04)0.216
The percent relative change in each parameter corresponding to a 1 log endotoxin increase.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Yoda, Y.; Tamura, K.; Otani, N.; Hasunuma, H.; Nakayama, S.F.; Shima, M. Reduction in Indoor Airborne Endotoxin Concentration by the Use of Air Purifier and Its Relationship with Respiratory Health: A Randomized Crossover Intervention Study. Atmosphere 2021, 12, 1523. https://0-doi-org.brum.beds.ac.uk/10.3390/atmos12111523

AMA Style

Yoda Y, Tamura K, Otani N, Hasunuma H, Nakayama SF, Shima M. Reduction in Indoor Airborne Endotoxin Concentration by the Use of Air Purifier and Its Relationship with Respiratory Health: A Randomized Crossover Intervention Study. Atmosphere. 2021; 12(11):1523. https://0-doi-org.brum.beds.ac.uk/10.3390/atmos12111523

Chicago/Turabian Style

Yoda, Yoshiko, Kenji Tamura, Naruhito Otani, Hideki Hasunuma, Shoji F. Nakayama, and Masayuki Shima. 2021. "Reduction in Indoor Airborne Endotoxin Concentration by the Use of Air Purifier and Its Relationship with Respiratory Health: A Randomized Crossover Intervention Study" Atmosphere 12, no. 11: 1523. https://0-doi-org.brum.beds.ac.uk/10.3390/atmos12111523

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop