Article

Combined Electro-Fenton and Anodic Oxidation Processes at a Sub-Stoichiometric Titanium Oxide (Ti4O7) Ceramic Electrode for the Degradation of Tetracycline in Water

1
Department of Chemical Sciences, University of Johannesburg, Doornfinten, Johannesburg 2028, South Africa
2
DST/Mintek Nanotechnology Innovation Centre, University of Johannesburg, Johannesburg 2028, South Africa
3
Centre for Nanomaterials Science Research, University of Johannesburg, Johannesburg 2028, South Africa
4
Institut Européen des Membranes, IEM, Univ Montpellier, CNRS, ENSCM, 34095 Montpellier, France
*
Authors to whom correspondence should be addressed.
Submission received: 24 August 2021 / Revised: 22 September 2021 / Accepted: 23 September 2021 / Published: 6 October 2021
(This article belongs to the Special Issue Application of Electrochemistry in Wastewater Treatment)

Abstract

:
The mineralization of tetracycline by electrochemical advanced oxidation processes (EAOPs) as well as the study of the toxicity of its intermediates and degradation products are presented. Electro-Fenton (EF), anodic oxidation (AO), and electro-Fenton coupled with anodic oxidation (EF/AO) were used to degrade tetracycline on carbon felt (cathode) and a sub-stoichiometric titanium oxide (Ti4O7) layer deposited on Ti (anode). As compared to EF and AO, the coupled EF/AO system resulted in the highest pollutant removal efficiencies: total organic carbon removal was 69 ± 1% and 68 ± 1%, at 20 ppm and 50 ppm of initial concentration of tetracycline, respectively. The effect of electrolysis current on removal efficiency, mineralization current efficiency, energy consumption, and solution toxicity of tetracycline mineralization were investigated for 20 ppm and 50 ppm tetracycline. The EF/AO process using a Ti4O7 anode and CF cathode provides low energy and high removal efficiency of tetracycline caused by the production of hydroxyl radicals both at the surface of the non-active Ti4O7 electrode and in solution by the electro-Fenton process at the cathodic carbon felt. Complete removal of tetracycline was observed from HPLC data after 30 min at optimized conditions of 120 mA and 210 mA for 20 ppm and 50 ppm tetracycline concentrations. Degradation products were elucidated, and the toxicity of the products were measured with luminescence using Microtox® bacteria toxicity test.

Graphical Abstract

1. Introduction

Pharmaceutical compounds have become of special interest in wastewater treatment because of their toxic effects on humans, aquatic lives, and the environment in general even at low concentrations [1,2,3,4]. Antibiotics are a class of pharmaceuticals that are extensively used to treat and prevent disease in humans and animals [5]. The concentrations of these antibiotics have been found to range between 116 and 750 ng/L in wastewater influents and 52 to 85 ng/L in effluents, worldwide [6]. The concentration of tetracycline (for example) has been found to be below 10 μg/L in surface water [2]. Tetracycline is an antibiotic used widely for human, animal, and agricultural purposes [3]. Due to the wide usage and poor absorption of tetracycline, it is excreted through feces and urine and has been found in surface water, ground water, and wastewater in many places around the world [2,7]. Occurrence of antibiotics in the environment is a probable cause of increasing presence of antibiotic resistant genes and bacteria, therefore efficient removal of tetracycline from wastewater is very important [8].
Tetracycline cannot be efficiently removed by biological treatments and techniques such as membrane filtration and adsorption do not break down the tetracycline but only transfers it from one phase to another [5]. Techniques such as advanced oxidation, namely photocatalysis, ozonation, ultrasound, sonoelectrochemistry, and various combinations of advanced technologies such as ultrasound with photocatalysis have been reported as alternative water treatment approaches to the elimination of tetracycline and other recalcitrant organic compounds in wastewater [1,7,8,9,10].
Electro-Fenton (EF) and anodic oxidation (AO) are promising water treatment processes under the class of electrochemical advanced oxidation processes (EAOPs) [11,12,13,14,15]. AO can be carried out, via water oxidation, on active or non-active anode of high overvoltage for oxygen evolution reaction, (Equation (1)) [14]. Examples of active anodes include carbon and graphite, iridium-based oxide, platinum-based oxide, etc., while non-active anodes include lead dioxide (PbO2) and boron-doped diamond (BDD) [14,15]. Ceramic Ti4O7, a sub-stoichiometric titanium dioxide of Magnéli phase, has also been identified as an efficient non-active anode for the degradation of recalcitrant substances. Pharmaceuticals like paracetamol were removed up to a maximum of 90% in 8 h, at an initial concentration of 10 ppm [16,17,18,19] whereas the removal rate of tetracycline after 120 min of treatment at the current densities of 0.5, 1.0, 2.0, and 3.0 mA cm−2 was 75.2%, 89.3%, 95.2%, and 97.6%, respectively [17]. For fluorite chemical compounds like perfluoroalkyl substances (PFAS), after 180 min of electrolysis, 93.1 ± 3.4% perfluorooctansulfonic acid (PFOS) was degraded and 90.3 ± 1.8% TOC was removed [20,21]. A titanium oxide (Ti4O7) anode generates large amounts of physisorbed hydroxyl radicals (Ti4O7 (HO·)) for the degradation and mineralization of organic contaminants. It also has the potential to become a low-cost anode compared to the well-known boron-doped diamond anode [13,18]. While in AO, hydroxyl radicals are generated at the surface, in the EF process, HO· (hydroxyl radicals) are generated in the bulk through the Fenton’s reaction (Equation (2)) where H2O2 and iron (II) are continuously electrogenerated at the cathode by the reduction of dissolved oxygen (Equation (3)) and reduction of iron (III) (Equation (4)), respectively. External oxygen is supplied continuously, and an iron source must be initially added at catalytic amount to the treated solution (homogeneous EF) [12,13].
M + H2O → M (HO·) + H+ + e
Fe2+ + H2O2 + H+ → Fe3+ + HO· + H2O
O2(g) + 2H+ + 2e → H2O2
Fe3+ + e → Fe2+
Homogeneous EF requires an external iron source and acidic pH (2.5–3) that prevents iron (III) precipitation [12]. Carbon felt has been used as a cathode material due to its good electronic conduction and high surface area. It is also very porous which then provides abundant redox reaction sites, combined with a suitable mechanical stability and a relatively low cost [22].
After the degradation process, toxicity tests can be used as an indicator of the acute toxicity of the effluents during the electrochemical treatment. The activity of the living cell could be reduced by the presence of toxic elements. Bioluminescence, which can be used to know the state of bacteria, has been reported for the determination of toxicity of samples [16].
In this study, an EF system with a carbon felt cathode was combined with an AO system with a ceramic Ti4O7 anode to form a combined EF/AO system as depicted in the scheme in Figure 1. Hydroxyl radicals are produced at both anode (Equation (1)) and cathode (Equations (2)–(4)). The oxygen was supplied to the cathode by the bubbling of air (Figure 1).
Using the combined EF/AO system, this study investigates the extent of mineralization, the toxicity of oxidation by-products, and degradation pathways resulting from the degradation of tetracycline. The work further proves the effectiveness of the coupling of the sub-stoichiometric Ti4O7 ceramic anode with carbon felt cathode for water treatment.

2. Materials and Methods

2.1. Chemicals

Tetracycline (TC), ferrous sulfate (heptahydrate), anhydrous sodium sulfate, organic solvents (HPLC grade), and all other chemicals were purchased from Sigma Aldrich (France) and used as received. All the solutions were prepared with high-purity water obtained from a Millipore MilliQ system with resistivity >18 MΩ.cm at room temperature.

2.2. Electrochemical Cell

The experiments were performed in a two-electrode cell system in an undivided cylindrical reactor of 500 mL capacity [19]. The anode is a Ti4O7 thick film deposited on the 2 faces of a Ti substrate (7.5 cm × 4 cm × 0.2 cm) by Saint-Gobain Coating Solution (France). The cathode is a carbon felt (Alfa Aesar, 25 cm × 5 cm × 0.63 cm). Tests were carried out using 230 mL of 0.045 mM (20 ppm TC) and 0.1125 mM (50 ppm TC) (corresponding to 11.88 mg/L and 29.70 mg/L TOC, respectively) in 50 mM Na2SO4 as supporting electrolyte, at room temperature. The anode was centered in the electrochemical cell and surrounded by the cathode, covering the inner wall of the cell. The bubbling of O2 started 10 min prior the experiments and was maintained throughout the experiments to keep it at a constant concentration. Continuous generation of H2O2 in situ was achieved by 2e reduction of dissolved oxygen at the carbon felt cathode.

2.3. Instrument Procedure

Hameg HM8040 was used to supply power to the cell at constant current. Mineralization of the TC in solutions was analyzed from total organic carbon (TOC) measurements (Shimadzu VCSH TOC analyzer). Reproducible TOC values, within ± 2% accuracy were found using the non-purgeable organic carbon method. The TOC values were used to calculate the mineralization current efficiency according to Equation (5):
M C E ( % ) = ( Δ T O C ) exp   n F V s 4.32 × 10 7   m l t × 100
where (ΔTOC)exp (mgC.L−1) is the TOC decay at time t (h), F is the Faraday constant (96,487 C mol−1), vs. is the solution volume (L), 4.32 × 107 is a conversion factor (=3600 s h−1 × 12,000 mg of C mol−1), m is the number of carbon atoms of TC (22 carbon atoms), I is the applied current (A), and n is the number of electron consumed per molecule of TC; taken to be 90 assuming complete mineralization of TC into CO2, NH4+ and H2O according to Equation (6).
C22H24N2O8 + 36H2O → 22CO2 + 2NH4+ + 88H+ + 90e
TOC results were also used to determine the energy consumption (EC) expressed as kWh. (g TOC−1) was removed and calculated from Equation (7).
E C ( kWh . ( g   TOC ) 1 ) = E c e l l I t V Δ ( T O C ) exp
where Ecell is the average cell voltage (V), I the applied current (A), t the duration of electrolysis (h), vs. the volume of solution treated (mL), and Δ(TOC)exp the experimental decays of TOC (mgC.L−1).
Furthermore, the amount of iron (Fe) in the solution was measured using atomic absorption spectroscopy (AAS) GBC 909 AA (Gbc Scientific; Melbourne, Australia) at a 386.0 nm wavelength and a lamp current of 7.0 mA.

2.4. Toxicity Tests

The toxicity of TC and the intermediate by-products formed during degradation was determined by a Microtox® bacteria toxicity test on a Microtox® Model 500 Analyzer (Modern Water Inc., London, UK), which measures the luminescence of marine bacteria [21]. The bacteria strain used was Vibrio fischeri NRRL B-11177. This bacterium emitted luminescence during growth relating to cellular respiration which is linked to cell activity. The acute toxicity tests results are interpreted by the MicrotoxOmni® software, whereas a screening test of 81.9% was used to characterize the inter-sample toxicity variability and identify the relative toxicity of each sample solution in this study. A 22% NaCl solution was used to allow Vibrio fischeri normal activity and thus luminescence emission. The pH of samples was adjusted to between 6.5 and 7.5 before the bacteria luminescence analysis using sodium hydroxide (0.1 M NaOH) or sulfuric acid (0.1 M H2SO4).
The inhibition rate at time t: I (t) was calculated using Equation (8):
i ( t ) % = 1 L U ( t ) L U ( 0 ) × 100
LU(0) is the initial intensity of luminescence emitted by the bacteria before the addition of the sample. LU(t) is the intensity of luminescence emitted by bacteria after t = 15 or 30 min of contact with the sample. Since the luminescence of the bacteria decreases over time (in the absence of toxicity), there is need to compensate for the errors due to the variability of the luminescence R(t) of the bacteria in a control solution (MilliQ water and NaCl) which gives the LU(0) values, Equation (9).
R ( t ) = L U 0 ( t ) L U 0 ( 0 )
The intensity of luminescence emitted by bacteria after a t = 15 or 30 min of contact with the control solution (MilliQ water and NaCl) is LU0(t); while the initial intensity of bacteria luminescence before the addition of the control solution is LU0(0). Equation (10) then depicts the corrected inhibition rate attributed to the toxicity of the sample:
I c ( t ) % = 1 L U ( t ) R ( t ) × L U ( 0 ) × 100

2.5. Tetracycline and By-Product Analysis

Tetracycline and its degradation products were analyzed by high-performance liquid chromatography coupled to mass spectrometry (HPLC-MS) with instruments and similar setting as reported in our previous work [10] as follows: HPLC was performed with a Waters 2695 pump, auto sampler with a 20 µL loop, a Waters 2695 separation module (HPLC), a Waters Micromass (Wythenshawe, Manchester, UK) and a Quattro Micro mass spectrometer equipped with electrospray ionization (ESI). For HPLC, Waters-XSelect HSST3 100 mm × 2.1 mm, 2.5 µm particles size with column temperature set at 25 °C was used. Buffer A (HPLC grade water + 0.1% formic acid) and Buffer B (HPLC grade acetonitrile + 0.05% formic acid) were used as mobile phase with a constant flow rate of 0.25 mL/min to the mass spectrometer. The following isocratic elution profile was applied: 90% A-10% B-Run = 2 min. A triple quadruple MS was operated in selected-ion-monitoring (SIR) mode with compounds being ionized in the negative electrospray ionization mode. For optimum sensitivity, the MS was adjusted to facilitate the ionization process. The detection conditions were: capillary potential 3.5 kV, cone potential 30 V, source temperature 120 °C, desolvation temperature 450 °C, cone gas flow 50 L/h, and desolvation gas flow 450 L/h. Nitrogen was used as the nebulizer gas. The limit of detection (LOD) and limit of quantification (LOQ) for 20 ppm was 0.15 and 0.45 ppm, respectively and 50 ppm was 0.18 and 0.51 ppm, respectively.
Oxalic and Oxamic acid were identified by chromatography using a Dionex Thermofisher ICS1000 system with Dionex Thermofisher VWD-3100 UV-Visible detector and a Benson Polymeric BP-OA-2000-0 column at room temperature. The eluent was H2SO4 0.05 N at 0.4 mL/min, and the analysis was performed at 210 nm.

3. Results

3.1. Effect of the Combination of Anodic Oxidation and Electro-Fenton Processes on the Mineralization of Tetracycline

EF, AO, and EF/AO experiments were carried out for the mineralization of TC at a constant applied current of 120 mA for 20 ppm TC and of 210 mA for 50 ppm TC (Figure 2a,b). For the EF experiment, CF and Pt mesh were used as the cathode and anode respectively in the presence of a 0.2 mM Fe2+ catalyst. Whereas in AO, Ti4O7 and Pt served as anode and cathode respectively without the addition of iron catalyst. Finally, EF/AO was carried out using a Ti4O7 anode and CF cathode with the addition of 0.2 mM Fe2+ catalyst. These experiments were conducted for 4 h using 0.05 mM Na2SO4 as supporting electrolyte at pH 3. After 240 min of electrolysis, TOC removal efficiency, for the solution containing 20 ppm of TC, was 41 ± 1%, 62 ± 1% and 65 ± 1% using EF, AO, and EF/AO, respectively. A similar trend was observed with 50 ppm TC where 51 ± 1%, 61 ± 2% and 68 ± 1% TOC removal was recorded using EF, AO, and EF/AO respectively (Table 1).
Regardless of the initial concentration of TC, we noted a sharp increase in the TOC removal in the first hour of electrolysis when operating with EF, AO, and EF/AO. However, the percentage of TOC removal was higher for AO and EF/AO than that of EF throughout the duration of the experiment (Figure 2a,b). There was no marked difference between the percentage of TOC removal for AO and EF/AO in the 20 ppm tetracycline. However, a better performance of the EF/AO is observed at a higher tetracycline concentration of 50 ppm. The 50 ppm concentration will need a higher number of hydroxyl radicals for degradation. Hence, the combined EF/AO generated more radicals for 50 ppm than the AO alone and this explains why the combined method performed better at higher tetracycline concentrations.
Higher removal efficiency obtained in EF/AO process can rightly be attributed to the combined effect of AO taking place at the Ti4O7 (anode) surface due to physisorbed hydroxyl radicals and the simultaneous Fenton process happening at the carbon felt cathode. Lin et al. [19] recently showed that TC removal on a Magnéli phase Ti4O7 porous anode was mainly due to reactions mediated by hydroxyl radical production. For a combined method such as AO/EF, a high mineralization rate of TC on BDD by coupling AO/EF on BDD or Pt at the anode and cathodic heterogeneous electro-Fenton process, have been reported [23]. It has been shown that the replacement of Pt anode with a cheaper Ti4O7 anode facilitated the production of physisorbed hydroxyl radicals due to its high overvoltage for oxygen evolution reaction (OER potential > 0.7 V) compared to the Pt anode (OER potential < 0.4 V) [17]. To go further considering the equipment cost of the system, it is evident that the replacement of BDD anodes by cost-effective Ti4O7 electrodes will be of great interest.

3.2. Mineralization Current Efficiency and Energy Consumption of the Coupled Process

Mineralization current efficiency (MCE) was calculated during the removal of 20 and 50 ppm TC at 120 mA and 210 mA, respectively for EF, AO, and EF/AO (Figure 3a,b). A similar trend to TOC removal in Figure 2 is observed where the MCE is highest for the combined EF/AO especially at a 50 ppm concentration (Figure 3b). This is due to the production of hydroxyl radicals at the surface of the anode which can oxidize TC more efficiently.
Regardless of the process (EF, AO, or EF/AO) and the anode materials used, the MCE progressively decayed over time at 20 ppm and 50 ppm TC concentrations (Figure 3). This decay is due to (i) the reduction in the concentration of organic matter in the solution that can lead to reduction in mass transport, (ii) the formation of more recalcitrant degradation by-products which are more difficult to for the hydroxyl radical to oxidize, and (iii) the reduction in the concentration of HO/M(HO·) in the solution as a result of the formation of scavengers which can compete with the oxidation of organic matter [24,25,26].
The combination of EF/AO was used for all the following experiments because of the interest of the coupling previously demonstrated. Additionally, investigations of the effect of different applied currents on the energy consumption (EC), at 20 and 50 ppm TC, were carried out (Table 2). The results presented in Table 2 show that, at a given time, the higher current density, the more energy consumption required. For the highest current density at 20 ppm TC, this is mainly related to the cell voltage increase because Δ(TOC)exp is almost constant (Figure 4a).
Figure 4a,b present the TOC removal for the coupled process as a function of time. There was a significance increase in TOC removal when current was increased from 80 mA to 120 mA than when increased from 120 mA to 300 mA for 20 ppm especially (Figure 4a). Figure 4b also shows a similar trend of higher TOC increase from 120 mA to 210 than from 210 mA to 300 mA. This is due to reduction in the oxidation ability of the processes due to progressive enhancement of parasitic reactions for high current values that consume the generated hydroxyl radicals without contributing efficiently to the mineralization of organics and then decrease MCE [16]. This could also be due to the loss of hydroxyl radicals because of dimerization to form H2O2 or production of hydroxyl ions upon reaction with ferrous ions. A major reason for the TOC removal trend observed with the use of 80 mA is partly due to the insufficient current to facilitate the generation of substantial oxidants for the degradation. We measured the amount of iron present in the solution at time intervals and a decrease in the concentration of iron was observed after 30 min. The reduction in iron could have been due to the iron-scavenging effect of oxalic acid by-product. Thus, in addition to the low current, the TOC removal at 80 mA is also due to the low concentration of iron in the solution. The low concentration of iron could not generate the needed amount of hydroxyl radicals. However, at higher currents more oxidants were being produced before the inhibition of iron could happen.
In the same way, an increase in applied current from 80 to 120 mA for 20 ppm (Figure 3b) or from 120 to 210 mA for 50 ppm (Figure 4d) led to an increase in MCE, indicating that the hydroxyl radicals were used efficiently in the oxidation of organic molecules, thus minimizing side reactions [27]. It is also worth noting that for 20 ppm TC, the TOC removal reaches a plateau if applying a current of 80 mA definitely because of the low production of radicals for mineralization of 20 ppm TC at this current value as explained earlier. Based on these results, an applied current of 120 and 210 mA for an efficient removal of tetracycline at 20 ppm and 50 ppm respectively seems to be the best compromise to get a high removal rate, low EC, and high MCE. The measurements done for iron for 120 mA and 210 mA, 20 and 50 ppm, respectively, have proved that more hydroxyl radicals were formed because the iron concentration was high. The current applied was able to convert the ferric ions into active ferrous ions.

3.3. Tetracycline Degradation and By-Producs Identification Using EF/AO Process

The monitoring of tetracycline concentration by HPLC-MS further proved that the current value applied to the electrochemical cell plays a major role not only for TOC removal, but also for fast organic pollutant degradation. For 20 ppm TC (Figure 5a), an applied current of 80 mA resulted in 97.5% tetracycline removal (i.e., 2.5% of residual TC) after 30 min. However, there was no TC detected after 1 h with applied currents of 80, 120, and 300 mA. A complete disappearance of the pollutant was then achieved in a very short time Yahiaoui et al. [28] and Wu et al. [29] also reported a complete disappearance of TC, however, with different approaches. For 50 ppm (Figure 5b), a complete degradation of TC was observed for 120 mA at 4 h, for 210 mA at 3.5 h, and for 300 mA at 30 min.
Three degradation by-products (P1, P2, and P3) of TC were identified during the process and summarized Table 3 for the treatment of 20 ppm of TC at 120 mA and 50 ppm of TC at 210 mA (previously identified as the optimized currents). At 30 min, P1 represents the main by-product, 81 ± 1%, whatever the initial concentration of TC. P1 has been identified by Dalmazio et al. [30] during the monitoring of the degradation of tetracycline by ozone in aqueous medium. After 30 min, P2 was identified in the solution at 20 ppm TC initial concentration at 52 ± 1% (i.e., P1 48 ± 1%), whereas P3 was identified only in the solution at 50 ppm at 50 ± 1% (i.e., P1 50 ± 1%). It should be noted that none of them were detected at 60 min of electrolysis, which proves their fast degradation as intermediate products.
The mass spectrometry in the positive ion mode, ESI(+)-MS (Table 3), shows that TC, detected in its protonated form ([1 + H]+) of m/z 445, reacted to yield two products. These products are P1 and P2 for 20 ppm and P1 and P3 for 50 ppm (Figure 6). The P1 product was identified for both 20 and 50 ppm. The isomer of TC which is P1 happened at C22, the exchange of amine group with carbonyl and formed a hydroxyl. Compound P2 from P1, produced by demethylation at C3, removal of the methanol group at C3, addition of alkoxyl group (-O-CH3) at C5, removal of carbonyl O at C8 (ketone removal), substitution of amine group with carbonyl group at C22, addition of methyl group in exchange of OH at C22, hydrolysis (reduction) of ketone at C10 to OH, oxidation at C12 from alcohol to ketone and reduction at C14 from ketone to OH. From isomer to P3, the following formations happened, substitution of secondary amine with an alkyl group at C7 (substitution of N with C), addition of carbonyl (ketone) oxygen; oxidation at C8, C10, C12, C14, same as P2 and then alkylation at C1 (addition of ethyl group). Other studies using HPLC-ESI-Q-TOF-MS/MS to determine the photodegradation products of TC in UV direct photolysis indicated that TC still contained the characteristic structure of tetra-phenyl though some of their substituent groups changed, resulting in a lower steric resistance [31].
Furthermore, short-chain carboxylic acids were identified from the degradation of the above by-products (P1, P2, and P3) from 1 h to 4 h treatment time. The carboxylic acids by-products shown in the chromatograms were oxalic and oxamic acids. After 4 h, oxalic acid was detected at 1.20 mg L−1 and 1.55 mg L−1 which represent 9.9% and 5.0% of the initial carbon content for 20 ppm TC and 50 ppm TC initial solutions, respectively. In the same way, after 4 h, oxamic acid was detected at 0.88 mg L−1 and 1.48 mg L−1 which represent 7.2% and 4.8% of the initial carbon content for 20 ppm TC and 50 ppm TC of the initial solutions, respectively. Obviously, C content of the identified carboxylic acids (i.e., oxalic and oxamic) represents only 17.1% and 9.8% of the initial C content of the solution for 20 ppm TC and 50 ppm TC, respectively. Whereas Yuan et al. (2011) found that TC initial by-products were more toxic than the short carboxylic acids which can be degraded easily biologically. These non-toxic by-products include hydroxymalonic acid, 1, 4-benzenedicarboxylic acid, propanedioic acid, 4-oxo-pentanoic acid, glycerin, some aliphatic acids, etc. which were determined by GC–MS analysis. All these identified compounds were unequivocally identified using the NIST98 library database with fit values higher than 90% [31].

3.4. Toxicity Assessment during Tetracycline Degradation Using EF/AO Process

The toxicity evolution of 230 mL of 20 ppm and 50 ppm TC treated at 120 mA and 210 mA respectively were measured by monitoring the luminescence inhibition of the marine bacteria Vibrio fischeri after 15 min and 30 min of exposure. The average values of luminescence inhibition after 15 and 30 min of exposure are given as a function of electrolysis time (Figure 7). A solution with an initial TC concentration of 20 ppm (Figure 7a) showed an initial increase in toxicity at t = 30 min after 15 min of exposure time, then a decrease which indicates that the initial by-products mix is more toxic than the following by-products for the solution at initial TC concentration of 20 ppm. The % inhibition luminescence LD50 values for 20 ppm TC at 15 min and 30 min, were 21.60 and 22.15, respectively. However, for the TC solution at 50 ppm, at t = 30 min the by-products showed less toxicity as compared to the initial TC concentration (Figure 7b). In this case the toxicity of the initial product was high compared to the final by-products, which indicates a gradual decrease in toxicity with electrolysis. It shows that toxicity decreased from 58% to 19% inhibition and from 70% to 28% for 15 min and 30 min of exposure time, respectively. Where the % inhibition luminescence LD50 for 50 ppm TC, at 15 min and 30 min was 49.02 and 60.58, respectively. The decrease in the solution toxicity proved that the intermediate products formed are less toxic than the initial TC sample. Based on Figure 7a,b we can then conclude (i) the measurements of luminescence inhibition is reliable because of the good correlation for measurements after 15 min and 30 min of exposure time for each solution (i.e., 20 and 50 ppm), (ii) in as little as 30 min of electrolysis time, the electrochemical advanced oxidation process induces a decrease of the toxicity, (iii) the toxicity of the solution increase with the TC concentration, and (iv) a threshold effect is observed between 20 and 50 ppm of TC because of the huge increase of the initial TC toxicity at 50 ppm compared to 20 ppm (i.e., 70 to 85% luminescence inhibition and 15 to 19% for 50 and 20 ppm respectively as proved by Figure 7a,b).

4. Conclusions

The mineralization of tetracycline by electrochemical advanced oxidation processes (EAOPs) using Ti4O7 as anode and carbon felt as the cathode was successful. The complete elimination of tetracycline was achieved after 30 min of electrolysis for both 20 and 50 ppm. The results for TOC removal using different EAOPs showed that EF/AO (65 ± 1% and 68 ± 1%, TOC removal at 20 ppm and 50 ppm TC, respectively) was more efficient compared to EF (TOC removal 41 ± 1% and 51 ± 1% at 20 ppm and 50 ppm, respectively) and AO (TOC removal 62 ± 1% and 61 ± 1% at 20 ppm and 50 ppm, respectively). The optimal applied current was 120 mA and 210 mA, for 20 ppm and 50 ppm, respectively when using the EF/AO process. Applied current plays a major role in degradation of organic pollutants. The higher the applied current the higher TOC removal. The identification and evolution of intermediate products, as well as the toxicity of the solution were also examined along the EF/AO process. After 30 min treatment time, P1 by-product was identified at 81 ± 1% for both 20 ppm (120 mA) and 50 ppm (210 mA) TC initial concentration. Then a mix of P1 (52 ± 1%) and P2 (48 ± 1%) and P1 (50 ± 1%) and P3 (50 ± 1%) were identified for the solution of 20 ppm and 50 ppm TC initial concentration respectively. These by-products produced smaller carboxylic acids (oxamic and oxalic) leading to a decrease in the toxicity of the initial TC solution showing that Ti4O7 can be used as an efficient and cost-effective anode in EF/AO processes for the mineralization of pharmaceuticals.

Author Contributions

Conceptualization, M.C. and O.A.A.; funding acquisition, O.A.A.; investigation, B.N.Z., C.G., E.P. and V.B.; methodology, B.N.Z., B.O.O., E.P., V.B., G.L., M.R., M.C. and O.A.A.; resources, M.C. and O.A.A.; supervision, N.M., M.C. and O.A.A.; writing—original draft, B.N.Z.; writing—review and editing, B.O.O., B.A.K., N.M., C.G., G.L., M.R., M.C. and O.A.A. All authors have read and agreed to the published version of the manuscript.

Funding

The authors gratefully acknowledge the following institutions in South Africa for funding: The National Research Foundation (CPRR Grant number: 118546); Water Research Commission (Grant Number: K5/2567); Centre for Nanomaterials Science Research, University of Johannesburg; Faculty of Science, University of Johannesburg; DST/Mintek Nanotechnology Innovation Centre, University of Johannesburg (UJ).

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

The data presented in this study are available on request from the corresponding author.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Daghrir, R.; Drogui, P. Tetracycline antibiotics in the environment: A review. Environ. Chem. Lett. 2013, 11, 209–227. [Google Scholar] [CrossRef]
  2. Kanama, K.M.; Daso, A.P.; Mpenyana-Monyatsi, L.; Marthie, A.A.; Coetzee, M.A.A. Assessment of pharmaceuticals, personal care products, and hormones in wastewater treatment plants receiving inflows from health facilities in North West Province, South Africa. J. Toxiloc. 2018, 2018, 3751930. [Google Scholar] [CrossRef]
  3. Rogowska, J.; Cieszynska-Semenowicz, M.; Ratajczyk, W.; Wolska, L. Micropollutants in treated wastewater. Ambio 2020, 49, 487–503. [Google Scholar] [CrossRef] [Green Version]
  4. Palominos, R.A.; Mondaca, M.A.; Giraldo, A.; Peñuela, G.; Pérez-Moya, M.; Mansilla, H.D. Photocatalytic oxidation of the antibiotic tetracycline on TiO2 and ZnO suspensions. Catal. Today 2009, 144, 100–105. [Google Scholar] [CrossRef]
  5. Zelalem, B.; Meareg, A. Recent reports on electrochemical determination of selected antibiotics in pharmaceutical formulations: A mini review. Electrochem. Commun. 2020, 121, 106863. [Google Scholar]
  6. Hubeny, J.; Harnisz, M.; Korzeniewska, E.; Buta, M.; Zieliński, W.; Rolbiecki, D.; Giebułtowicz, J.; Nałęcz-Jawecki, G.; Płaza, G. Industrialization as a source of heavy metals and antibiotics which can enhance the antibiotic resistance in wastewater, sewage sludge and river water. PLoS ONE 2021, 16, e0252691. [Google Scholar] [CrossRef]
  7. Patel, M.; Kumar, R.; Kishor, K.; Mlsna, T.; Pittman, C.U., Jr.; Mohan, D. Pharmaceuticals of emerging concern in aquatic systems: Chemistry, occurrence, effects, and removal methods. Chem. Rev. 2019, 119, 3510–3673. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  8. Gopal, G.; Alex, S.A.; Chandrasekaran, N.; Mukherjee, A. A review on tetracycline removal from aqueous systems by advanced treatment techniques. RSC Adv. 2020, 10, 27081–27095. [Google Scholar] [CrossRef]
  9. Gangadhar, A.; Ekaterina, V.R.; Rominder, P.S.S. Evaluation of relative importance of ultrasound reactor parameters for the removal of estrogen hormones in water. Ultrason. Sonochem. 2012, 19, 953–958. [Google Scholar]
  10. Theerthagiri, J.; Lee, S.J.; Karuppasamy, K.; Arulmani, S.; Veeralakshmi, S.; Ashokkumar, M.; Choi, M.Y. Application of advanced materials in sonophotocatalytic processes for the remediation of environmental pollutants. J. Hazard. Mater. 2021, 412, 125245. [Google Scholar] [CrossRef] [PubMed]
  11. Orimolade, B.O.; Zwane, B.N.; Koiki, B.A.; Rivallin, M.; Bechelany, M.; Mabuba, N.; Lesage, G.; Cretin, M. Coupling cathodic electro-fenton with anodic photo-electrochemical oxidation: A feasibility study on the mineralization of paracetamol. J. Environ. Chem. Eng. 2020, 5, 104394. [Google Scholar] [CrossRef]
  12. Oturan, M.A.; Aaron, J.J. Advanced oxidation processes in water/wastewater treatment: Principles and applications. A review. Crit. Rev. Environ. Sci. Technol. 2014, 44, 2577–2641. [Google Scholar] [CrossRef]
  13. Brillas, E.; Sirés, I.; Oturan, M.A. Electro-fenton process and related electrochemical technologies based on fenton’s reaction chemistry. Chem. Rev. 2009, 109, 6570–6631. [Google Scholar] [CrossRef] [PubMed]
  14. Trellu, C.; Oturan, N.; Pechaud, Y.; Hullebusch, E.D.; Esposito, G.; Oturan, M.A. Anodic oxidation of surfactants and organic compounds entrapped in micelles—Selective degradation mechanisms and soil washing solution reuse. Water Res. 2017, 118, 1–11. [Google Scholar] [CrossRef]
  15. Panizza, M.; Brillas, E.; Comninellis, C. Application of boron-doped diamond electrodes for wastewater treatment. J. Environ. Eng. Manag. 2008, 18, 139–153. [Google Scholar]
  16. Ouarda, Y.; Trellu, C.; Lesage, G.; Rivallin, M.; Drogui, P.; Cretin, M. Electro-oxidation of secondary effluents from various wastewater plants for the removal of acetaminophen and dissolved organic matter. Sci. Total Environ. 2020, 738, 140352. [Google Scholar] [CrossRef]
  17. Ganiyu, S.O.; Oturan, N.; Raffy, S.; Cretin, M.; Causserand, C.; Oturan, M.A. Efficiency of plasma elaborated sub-stoichiometric titanium oxide (Ti4O7) ceramic electrode for advanced electrochemical degradation of paracetamol: In different electrolyte media. Sep. Pur. Technol. 2019, 208, 142–152. [Google Scholar] [CrossRef] [Green Version]
  18. Ganiyu, S.O.; Oturan, N.; Raffy, S.; Esposito, G.; Hullebusch, E.D.; Cretin, M.; Oturan, M.A. Use of sub-stoichiometric titanium oxide as a ceramic electrode in anodic oxidation and electro-fenton degradation of the beta-blocker propranolol: Degradation kinetics and mineralization pathway. Electrochim. Acta 2017, 242, 344–354. [Google Scholar] [CrossRef]
  19. Lin, H.; Niu, J.; Liang, S.; Wang, C.; Wang, Y.; Jin, F.; Luo, Q.; Huang, Q. Development of macroporous Magnéli phase Ti4O7 ceramic materials: As an efficient anode for mineralization of poly- and perfluoroalkyl substances. Chem. Eng. J. 2018, 354, 1058–1067. [Google Scholar] [CrossRef]
  20. Liang, S.; Lin, H.; Yan, X.; Huang, Q. Electro-oxidation of tetracycline by a Magnéli phase Ti4O7 porous anode: Kinetics, products, and toxicity. Chem. Eng. J. 2018, 332, 628–636. [Google Scholar] [CrossRef]
  21. Le, T.X.H.; Haflich, H.; Amisha DShah, A.D.; Chaplin, B.P. Energy-efficient electrochemical oxidation of perfluoroalkyl substances using a Ti4O7 reactive electrochemical membrane anode. Environ. Sci. Technol. Lett. 2019, 6, 504–510. [Google Scholar] [CrossRef]
  22. Le, T.X.H.; Bechelany, M.; Cretin, M. Carbon felt based-electrodes for energy and environmental applications: A review. Carbon 2017, 122, 564–591. [Google Scholar]
  23. Chen, T.S.; Tsai, R.W.; Chen, Y.S.; Huang, K.L. Electrochemical degradation of tetracycline on BDD in aqueous solutions. Int. J. Electrochem. Sci. 2014, 9, 8422–8434. [Google Scholar]
  24. Le, T.X.H.; Nguyen, T.V.; Yacouba, Z.A.; Zoungrana, L.; Avril, F.; Petit, E.; Mendret, J.; Bonniol, V.; Bechelany, M.; Lacour, S.; et al. Toxicity removal assessments related to degradation pathways of azo dyes: Toward an optimization of electro-fenton treatment. Chemosphere 2016, 161, 308–318. [Google Scholar] [CrossRef]
  25. Barhoumi, N.; Olvera-Vargas, H.; Oturan, N.; Huguenot, D.; Gadri, A.; Ammar, S.; Brillas, E.; Oturan, M.A. Kinetics of oxidative degradation/mineralization pathways of the antibiotic tetracycline by the novel heterogeneous electro-Fenton process with solid catalyst chalcopyrite. Appl. Catal. B Environ. 2017, 209, 637–647. [Google Scholar] [CrossRef]
  26. Ganiyu, S.O.; Oturan, N.; Trellu, C.; Raffy, S.; Cretin, M.; Causserand, C.; Oturan, M.A. Abatement of analgesic antipyretic 4-aminophenazone using conductive boron-doped diamond and sub-stoichiometric titanium oxide anodes: Kinetics, mineralization and toxicity assessment. ChemElectroChem 2019, 6, 1808–1817. [Google Scholar] [CrossRef] [Green Version]
  27. Sirés, I.; Oturan, N.; Oturan, M.A. Electrochemical degradation of β-blockers. Studies on single and multicomponent synthetic aqueous solutions. Water Res. 2010, 44, 3109–3120. [Google Scholar] [CrossRef]
  28. Yahiaoui, I.; Aissani-Benissad, F.; Fourcade, F.; Amrane, A. Removal of tetracycline hydrochloride from water based on direct anodic oxidation (Pb/PbO2 electrode) coupled to activated sludge culture. Chem. Eng. J. 2013, 221, 418–425. [Google Scholar] [CrossRef]
  29. Wu, J.; Zhang, H.; Oturan, N.; Wang, Y.; Chen, L.; Oturan, M.A. Application of response surface methodology to the removal of the antibiotic tetracycline by electrochemical process using carbon-felt cathode and DSA (Ti/RuO2–IrO2) anode. Chemosphere 2012, 87, 614–620. [Google Scholar] [CrossRef] [PubMed]
  30. Dalmázio, I.; Almeida, M.O.; Augusti, R.; Alves, T.M.A. Monitoring the degradation of tetracycline by ozone in aqueous medium via atmospheric pressure ionization mass spectrometry. J. Am. Soc. Mass Spectrom. 2007, 18, 679–687. [Google Scholar] [CrossRef] [Green Version]
  31. Yuan, F.; Hu, C.; Hu, X.; Wei, D.; Chen, Y.; Qu, J. Photodegradation and toxicity changes of antibiotics in UV and UV/H2O2 process. J. Hazard. Mater. 2011, 185, 1256–1263. [Google Scholar] [CrossRef] [PubMed]
Figure 1. Schematic representation of the combined electro-Fenton (EF) and anodic oxidation (AO) system for the degradation of tetracycline.
Figure 1. Schematic representation of the combined electro-Fenton (EF) and anodic oxidation (AO) system for the degradation of tetracycline.
Water 13 02772 g001
Figure 2. Tetracycline mineralization vs. electrolysis time for the degradation of 230 mL of TC at (a) 20 ppm (120 mA) and (b) 50 ppm (210 mA) by EF, AO, and EF/AO.
Figure 2. Tetracycline mineralization vs. electrolysis time for the degradation of 230 mL of TC at (a) 20 ppm (120 mA) and (b) 50 ppm (210 mA) by EF, AO, and EF/AO.
Water 13 02772 g002
Figure 3. Tetracycline MCE vs. time for the degradation of 230 mL of TC at (a) 20 ppm (120 mA) and (b) 50 ppm (210 mA) by EF, AO, and EF/AO.
Figure 3. Tetracycline MCE vs. time for the degradation of 230 mL of TC at (a) 20 ppm (120 mA) and (b) 50 ppm (210 mA) by EF, AO, and EF/AO.
Water 13 02772 g003aWater 13 02772 g003b
Figure 4. Tetracycline mineralization efficiency of EF/AO at different current on TC solutions in 0.05 M Na2SO4 at pH 3 using Ti4O7 anode (a) %TOC removal for 20 ppm TC, (b) %TOC removal for 50 ppm TC, (c) %MCE for 20 ppm TC and (d) %MCE for 50 ppm TC.
Figure 4. Tetracycline mineralization efficiency of EF/AO at different current on TC solutions in 0.05 M Na2SO4 at pH 3 using Ti4O7 anode (a) %TOC removal for 20 ppm TC, (b) %TOC removal for 50 ppm TC, (c) %MCE for 20 ppm TC and (d) %MCE for 50 ppm TC.
Water 13 02772 g004aWater 13 02772 g004b
Figure 5. Applied current effect on tetracycline residual rate (in %) determined by HPLC-MS for (a) 20 ppm TC at 80, 120, and 300 mA and (b) 50 ppm TC at 120, 210, and 300 mA using the EF/AO (Ti4O7 anode) process.
Figure 5. Applied current effect on tetracycline residual rate (in %) determined by HPLC-MS for (a) 20 ppm TC at 80, 120, and 300 mA and (b) 50 ppm TC at 120, 210, and 300 mA using the EF/AO (Ti4O7 anode) process.
Water 13 02772 g005
Figure 6. Possible reaction pathways based on molecular weight of TC by-products identified by LC-MS. Pathways TC/P1/P2 and TC/P1/P3 for the solution at 20 ppm and 50 ppm TC initial concentration respectively.
Figure 6. Possible reaction pathways based on molecular weight of TC by-products identified by LC-MS. Pathways TC/P1/P2 and TC/P1/P3 for the solution at 20 ppm and 50 ppm TC initial concentration respectively.
Water 13 02772 g006
Figure 7. Growth of the inhibition of marine bacteria luminescence of 20 ppm (a) and 50 ppm (b). TC taken after different EF/AO treatment. RSD (n = 3): 12% for inhibition < 20%; 5% for 20% < inhibition < 70% and 0% for inhibition > 70%.
Figure 7. Growth of the inhibition of marine bacteria luminescence of 20 ppm (a) and 50 ppm (b). TC taken after different EF/AO treatment. RSD (n = 3): 12% for inhibition < 20%; 5% for 20% < inhibition < 70% and 0% for inhibition > 70%.
Water 13 02772 g007
Table 1. Removal % of tetracycline (TC) at 20 ppm and 50 ppm by the different processes conducted at 120 mA for TC 20 ppm and 210 mA for TC 50 ppm during 4 h.
Table 1. Removal % of tetracycline (TC) at 20 ppm and 50 ppm by the different processes conducted at 120 mA for TC 20 ppm and 210 mA for TC 50 ppm during 4 h.
20 ppm50 ppm
EFAOEF/AOEFAOEF/AO
% TOC Removal41 ± 162 ± 165 ± 151 ± 161 ± 168 ± 1
Table 2. Energy consumption (EC) for the removal of 20 and 50 ppm tetracycline after 4 h of treatment by the coupled EF/AO process.
Table 2. Energy consumption (EC) for the removal of 20 and 50 ppm tetracycline after 4 h of treatment by the coupled EF/AO process.
20 ppm50 ppm
Current (mA)80120300120210300
TOC Removal (%)356567516168
EC (kWh (g TOC−1))0.140.110.210.050.080.12
Table 3. Mass spectrometry data of TC degradation products.
Table 3. Mass spectrometry data of TC degradation products.
ProductShort WrittenElemental CompositionMeasured Mass (M)
TC(M)+C22H24N2O8444.4
P1(M + H)+C22H25N2O8445.4
P2 (20 ppm)(M-N + CH)C23H26NO8443.4
P3 (50 ppm)(M-N + CH)C23H26NO8443.4
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Zwane, B.N.; Orimolade, B.O.; Koiki, B.A.; Mabuba, N.; Gomri, C.; Petit, E.; Bonniol, V.; Lesage, G.; Rivallin, M.; Cretin, M.; et al. Combined Electro-Fenton and Anodic Oxidation Processes at a Sub-Stoichiometric Titanium Oxide (Ti4O7) Ceramic Electrode for the Degradation of Tetracycline in Water. Water 2021, 13, 2772. https://0-doi-org.brum.beds.ac.uk/10.3390/w13192772

AMA Style

Zwane BN, Orimolade BO, Koiki BA, Mabuba N, Gomri C, Petit E, Bonniol V, Lesage G, Rivallin M, Cretin M, et al. Combined Electro-Fenton and Anodic Oxidation Processes at a Sub-Stoichiometric Titanium Oxide (Ti4O7) Ceramic Electrode for the Degradation of Tetracycline in Water. Water. 2021; 13(19):2772. https://0-doi-org.brum.beds.ac.uk/10.3390/w13192772

Chicago/Turabian Style

Zwane, Busisiwe N., Benjamin O. Orimolade, Babatunde A. Koiki, Nonhlangabezo Mabuba, Chaimaa Gomri, Eddy Petit, Valérie Bonniol, Geoffroy Lesage, Matthieu Rivallin, Marc Cretin, and et al. 2021. "Combined Electro-Fenton and Anodic Oxidation Processes at a Sub-Stoichiometric Titanium Oxide (Ti4O7) Ceramic Electrode for the Degradation of Tetracycline in Water" Water 13, no. 19: 2772. https://0-doi-org.brum.beds.ac.uk/10.3390/w13192772

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop