Comparison of Different Machine Learning Classifiers for Glaucoma Diagnosis Based on Spectralis OCT

1
Graduate Institute of Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung City 807378, Taiwan
2
Department of Ophthalmology, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung City 807378, Taiwan
3
Graduate Institute of Business Administration, Fu Jen Catholic University, New Taipei City 242062, Taiwan
4
Artificial Intelligence Development Center, Fu Jen Catholic University, New Taipei City 242062, Taiwan
5
Department of Information Management, Fu Jen Catholic University, New Taipei City 242062, Taiwan
6
Department of Industrial Engineering and Management, Ming Chi University of Technology, New Taipei City 243303, Taiwan
7
Center for Artificial Intelligence & Data Science, Ming Chi University of Technology, New Taipei City 243303, Taiwan
8
Department of Ophthalmology, Fu Jen Catholic University Hospital, New Taipei City 24352, Taiwan
9
School of Medicine, College of Medicine, Fu Jen Catholic University, New Taipei City 242062, Taiwan
*
Authors to whom correspondence should be addressed.
These authors contributed equally to this work.
Submission received: 16 August 2021 / Revised: 17 September 2021 / Accepted: 18 September 2021 / Published: 19 September 2021
(This article belongs to the Special Issue High-Tech Devices in the Diagnosis of Eye Diseases)

Abstract

:
Early detection is important in glaucoma management. By using optical coherence tomography (OCT), the subtle structural changes caused by glaucoma can be detected. Though OCT provided abundant parameters for comprehensive information, clinicians may be confused once the results conflict. Machine learning classifiers (MLCs) are good tools for considering numerous parameters and generating reliable diagnoses in glaucoma practice. Here we aim to compare different MLCs based on Spectralis OCT parameters, including circumpapillary retinal nerve fiber layer (cRNFL) thickness, Bruch’s membrane opening-minimum rim width (BMO-MRW), Early Treatment Diabetes Retinopathy Study (ETDRS) macular thickness, and posterior pole asymmetry analysis (PPAA), in discriminating normal from glaucomatous eyes. Five MLCs were proposed, namely conditional inference trees (CIT), logistic model tree (LMT), C5.0 decision tree, random forest (RF), and extreme gradient boosting (XGBoost). Logistic regression (LGR) was used as a benchmark for comparison. RF was shown to be the best model. Ganglion cell layer measurements were the most important predictors in early glaucoma detection and cRNFL measurements were more important as the glaucoma severity increased. The global, temporal, inferior, superotemporal, and inferotemporal sites were relatively influential locations among all parameters. Clinicians should cautiously integrate the Spectralis OCT results into the entire clinical picture when diagnosing glaucoma.

1. Introduction

Glaucoma is a potentially blinding disease, characterized by progressive degeneration of the retinal ganglion cells, resulting in distinct changes of the optic nerve head and corresponding visual field defect [1]. By observing the structural changes of the retinal nerve fiber layer, neuroretinal rim, or inner layer of macula, it is possible to detect the potential glaucoma patients [2].
Optical coherence tomography (OCT) is a non-invasive technology that enables high-resolution cross-sectional images of ocular tissues and provides objective quantitative data that have good reproducibility [3,4]. Through the various scan protocols provided by OCT, the subtle structural change caused by glaucoma can be detected earlier, even before the visual field loss would appear [5].
Although the abundant OCT parameters can give the clinicians a comprehensive understanding of the ocular structural changes, they may also cause confusion especially when the classification results conflict, usually seen in early-stage glaucoma due to the subtle structural changes [6]. There have been many studies investigating the diagnostic accuracy of parameters between normal and glaucomatous eyes [7,8,9,10,11,12,13], but most of them focused on individual parameters. However, in actual clinical situations, clinicians usually make the final diagnosis after considering all the parameters.
Machine learning classifiers (MLCs) are well-established analytical methods especially good at detecting the relationship between a huge amount of input parameters, eventually facilitating the diagnosis of a condition [14]. In fact, some reports suggest that MLCs are as good as [15,16], or even better [17,18,19,20,21,22,23,24] than, currently available techniques for glaucoma diagnosis. However, what most people criticize MLCs for is the analysis process being a “black box” [25,26,27], for it produces results based solely on the input data using an algorithm, which prevents clinicians from understanding how variables are being combined to make such a prediction. Through program analysis methods developed in recent years, we can study and analyze the importance of the included parameters in specific models, and ophthalmologists may obtain clinical insight from the explanation [24,25,28,29,30]. In this study, we aim to build MLCs based on clinical OCT data provided by Heidelberg Spectralis spectral-domain OCT (SD-OCT) to evaluate the diagnostic accuracy of MLCs and the importance of OCT parameters in diagnosing glaucoma of varying severities.

2. Materials and Methods

2.1. Participants

This cross-sectional study included 470 eyes from 265 participants. The patients with glaucoma were recruited from a group of patients who had received at least 6 months of regular follow-up at the Glaucoma Service of the Department of Ophthalmology at Fu Jen Catholic University Hospital (FJUH) between April 2019 to December 2021. Subjects with normal eyes were recruited from the out-patient clinic and staff at the Fu Jen Catholic University Hospital during the study period. This research adhered to the tenets of the Declaration of Helsinki. Informed consent was obtained from each participant, and the study was approved by the Institutional Review Board of FJUH (FJUH109020 and FJUH109021).
All the study subjects underwent complete ophthalmic examination, including slit-lamp biomicroscopy, measurement of intraocular pressure (IOP), stereoscopic fundus examination, and standard automated perimetry. Visual fields were carried out on a Humphrey Visual Field Analyzer (model 750, Carl Zeiss Meditec, Dublin, CA, USA) with a standard white-on-white 30-2 field with the standard full threshold program. Demographic and clinical information was recorded, including age, gender, best-corrected visual acuity (BCVA), IOP, spherical equivalent (SE), mean deviation (MD), and pattern standard deviation (PSD).
All participants were required to have a best-corrected visual acuity of 20/40 or better and a spherical equivalent within the −6.0 diopter (D) to +3.0 D range. Patients with significant ocular media opacity, coexisting retinal disease, or history of refractive or vitreoretinal surgery were excluded from this study. In addition, for increasing the imaging quality and accuracy, subjects with marked peripapillary atrophy were excluded to avoid instrumentation problems in the algorithms used to find the layers.
Normal control eyes had normal findings on clinical examination, IOPs lower than 21 mmHg, no history of increased IOP, no family history of glaucoma, normal-looking optic disc heads, and normal visual field results. A normal visual field result was defined as an MD and PSD within 95% confidence limits and a glaucoma hemifield test result within normal limits.
Eyes were defined as glaucomatous if there were glaucomatous optic neuropathy (GON) and corresponding visual field loss. We defined GON as either inter-eye cup-disc ratio asymmetry > 0.2, rim thinning or notching, peripapillary hemorrhages, or cup-disc ratio ≥ 0.2 [31,32]. Glaucomatous visual field defects were evaluated based on the following criteria: ≥2 contiguous points with a pattern deviation sensitivity loss of p-value < 0.01, ≥3 contiguous points with a sensitivity loss of p-value < 0.05 in the superior or inferior arcuate areas, or a 10-decibels (dB) difference across the nasal horizontal midline at ≥2 adjacent locations and an abnormal result on the glaucoma hemifield test [33]. Also, visual field defects had to be reproducible on at least one occasion. A visual field was considered reliable if there was <20% fixation loss, as well as <20% false-positive and false-negative rates. Both eyes of each participant were included if they were glaucomatous. All eyes with secondary glaucoma or evidence of visual field defects consistent with other diseases were excluded.
Using the Hodapp–Parrish classification [34], glaucomatous eyes were stratified into three groups for further analysis: early glaucoma (MD > −6 dB), moderate glaucoma (−12 dB < MD ≤ −6 dB), and severe glaucoma (MD ≤ −12 dB).

2.2. Spectralis OCT Imaging

All participants were examined with Spectralis (Heidelberg Engineering Inc., Heidelberg, Germany) SD-OCT, and the Anatomic Positioning System (APS) was used in the process. The APS creates an anatomic map using two fixed structural landmarks: the center of the fovea and the center of the Bruch’s membrane opening. All scan protocols are automatically oriented according to the patient’s anatomic map to obtain precise measurements of relevant structures and ensure accurate comparisons with reference data. Optic nerve head radial and circular (ONH-RC) scan protocol and the posterior pole horizontal (PPoleH) scan protocol were used in the current study to get four groups of parameters: circumpapillary retinal nerve fiber layer (cRNFL) thickness, Bruch’s membrane opening-minimum rim width (BMO-MRW), macular Early Treatment Diabetic Retinopathy (ETDRS) thickness map, and posterior pole asymmetry analysis (PPAA). The two scan protocols can be obtained in the new Glaucoma Premium Module Edition (GPME) software. All the above scans were performed by experienced technicians. No manual correction was applied to the auto-segmented OCT output. Images that had a quality index of less than 20 or images with artifacts were excluded.
The ONH-RC scan protocol consisted of three circular scans with diameters of 3.5 mm, 4.1 mm, and 4.7 mm to acquire the cRNFL thickness, and 24 equally spaced radial B-scans to get the BMO-MRW. Both of the circular and radial scans were centered on the optic nerve head. The BMO-MRW measurements were obtained by calculating the shortest distance between the BMO points and the internal limiting membrane, which was automatically identified by the build-in software. The cRFNL and BMO-MRW measurements were displayed in seven parts: global (G), temporal (T), superotemporal (TS), superonasal (NS), nasal(N), inferonasal (NI), and inferotemporal (TI) area. Each part averaged the corresponding measurements of the area. All of the seven BMO averages would be used to build the MLCs, but only the seven cRNFL averages generated by the 3.5 mm diameter circle would be included in the subsequent analysis.
The PPoleH scan protocol consists of 61 horizontal B-scans, centered on the fovea, oriented to the fovea-disc axis, and symmetrically distributed in the upper and lower hemispheres. It provides the automated segmented thickness map of each retinal layer, including macular retinal nerve fiber layer (mRNFL), ganglion cell layer (GCP), inner plexiform layer (IPL), inner nuclear layer, outer plexiform layer, outer nuclear layer, photoreceptors layer, and retinal pigment epithelium. These measurements are displayed in two modes: ETDRS mode and PPAA mode.
In the ETDRS mode, the thickness maps of total macular thickness and all eight retinal layers are provided in nine subfields as defined by the ETDRS. The diameters of inner, intermediate, and outer rings are 1, 3, and 6 mm separately. The average of all points with the inner ring was defined as central thickness (C). The intermediate ring was divided into four sectors designated as inner superior (S1), inner nasal (N1), inner inferior (I1), and inner temporal (T1) sector, and so was the outer ring, designated as outer superior (S2), outer nasal (N2), outer inferior (I2) and outer temporal (T2) sector. The values of the nine zones of total macular thickness, mRNFL, GCL, and IPL thickness were used in the following analysis.
In the PPAA mode, the thickness of the full retina and each retinal layer are measured, averaged and displayed in an 8 × 8 grid, corresponding to the central 24° area of the posterior pole. We only included the 64 measurements of full retinal thickness, labeled with the first number representing the order from top to bottom and the second number representing the order from temporal to nasal site.
In total, 114 parameters (7 RNFL, 7 MRW, 36 ETDRS, 64 PPAA) were used for subsequent MLC establishment (Supplemental Table S1). All the included subjects have no missing value in these 114 measurements.

2.3. Machine Learning Classifiers

Five machine learning algorithms, namely conditional inference trees (CIT), logistic model tree (LMT), C5.0 decision tree, random forest (RF), and extreme gradient boosting (XGBoost), are used to build the early, moderate, and severe glaucoma classification models. MLCs for normal and all glaucomatous eyes are also constructed. These machine learning algorithms have been widely applied in various healthcare and/or medical informatics applications and do not have a prior assumption about data distribution [35,36,37,38]. The multivariate logistic regression (LGR) was used as a benchmark for comparison. The 114 Spectralis OCT parameters are used as independent variables for all used methods to build glaucoma classification models.
The CIT uses recursive partitioning of dependent variables and embeds a permutation test to discriminate between significant and insignificant improvements [39]. The LMT combines decision tree and LGR where independent variables are splitting by a logistic variant information gain, LGR models at all nodes are produced by the LogitBoost, and its final decision tree is pruned by using the method of classification and regression trees [40]. The C5.0 decision tree is a successor of the C4.5 decision tree. The independent variables are splitting based on the entropy. The final tree is pruned by the binomial confidence limit method [41]. The RF is a bagging technique that builds a set of decision trees, that is, a forest, by randomly selecting samples and independent variables. The prediction class of RF is considered the majority vote [42]. The XGBoost is an extendible version of gradient boosting machines that was developed for the pursuit of pushing the limits of prediction performance and computational speed. In the boosting technique, boosted models are added recursively to adjust the residuals made by existing models. The final prediction is based on the majority votes [43].
In this study, all methods were implemented in R software version 3.6.2 (R core team, Vienna, Austria). For modeling LGR, CIT, LMT, C5.0, RF, and XGBoost models, the corresponding R packages “blorr” [44], “partykit” [45], “RWeka” [46], “C50” [47], “randomForest” [48], and “xgboost” [49] are used in this study. The R package “caret” [50] was used to tune the hyper-parameters of each machine learning method.
In building the predictive model, we first reorganized the dataset into three sub-datasets, normal vs. early glaucoma, normal vs. moderate glaucoma, and normal vs. severe glaucoma. Next, we randomly divided each sub-dataset with a specific percentage several times. A split of 80–20 is used, where the training dataset gets 80% and the testing dataset gets 20% of the total data.
During the training stage, we attempted to tune the hyper-parameters of each MLC to find out a model whose prediction performance is relatively good. We conducted the pipeline of a random search, 10-fold cross-validation, and a metric evaluation using “caret” R package. Within the pipeline, the random search generated 50 sets of hyper-parameters of each classifier that followed uniform distribution. For each hyper-parameter set, the training dataset was further divided into 10 equal-sized folds. Of the 10 folds, 9 folds are used as the real training dataset for training the classifier, whereas the remaining single fold is treated as the validation dataset for evaluating the performance by using the area under the receiver operating characteristic curve (AUC). The 10-fold cross-validation was repeated 10 times by changing the fold of the validation dataset and an average AUC of a given set of hyper-parameters was produced. The higher the average AUC is, the better the hyper-parameters of a classifier will be.
During the testing stage, the features were fed into the best model to get the predicted classification result of each sample. Finally, all predicted results were compared with their corresponding labels to generate a confusion matrix that can be used to calculate the performance metrics of a classifier.
For each classifier, the above process was randomly repeated 100 times for bootstrap samples of the data. The 100 recorded accuracy, sensitivity, specificity, and AUC of each classifier were averaged separately as the performance metric of each MLC. The mean rank aggregation method [30,51] was used to average the yielded 100 results of variable importance ranking of a classifier to produce a combined variable importance ranking for each MLC.

2.4. Statistical Analysis

All statistical analyses were carried out using the statistical programming language R software of version 3.6.2 (R core team, Vienna, Austria). Demographics and clinical characteristics of the study groups were compared using the Mann–Whitney U test for quantitative variables and the Chi-square test for categorical variables.

3. Results

The demographics and clinical characteristics of the study groups are given in Table 1. The age of the glaucoma groups was significantly older than the normal group (p < 0.001), and the BCVA of the glaucoma groups was significantly worse than the normal group (p < 0.001). No significant difference was observed in the IOP and spherical equivalent. Visual field parameters including MD and PSD showed significant differences between the two groups (p < 0.001).
The LGR, CIT, LMT, C5.0, RF, and XGBoost methods were used to build classification models for discriminating all glaucomatous eyes from normal eyes. They were also used for distinguishing between early, moderate, and severe glaucoma from normal conditions. The model performance, that is, the mean and the standard deviation (SD) of accuracy, sensitivity, specificity, and AUC, of all models for all, early, moderate, and severe glaucoma datasets are respectively presented in Table 2, Table 3, Table 4 and Table 5. The receiver operating characteristic (ROC) curves as well as 95% confidence interval (CI) of mean AUCs of all classifiers for all, early, moderate, and severe glaucoma datasets are also demonstrated in Figure 1.
It can be observed from Table 2 and Figure 1a that all five MLCs can generate better performance than the benchmark LGR method (mean AUC = 0.7788) in all the glaucoma eyes datasets. RF provides the highest value of average accuracy (0.8818), average sensitivity (0.9166), average specificity (0.8507), and average AUC (0.9459). RF is the best predictive model in all the glaucoma eyes datasets and its mean AUC and 95% CI is 0.9459 ± 0.0047.
Referring to Table 3 and Figure 1b, it can be found that that the model performance of MLCs outperforms that of the benchmark LGR method (mean AUC = 0.6860) in the early dataset. The model performance of CIT and LMT are lower than that of C5.0, RF, and XGBoost algorithms. XGBoost receives the highest value of average sensitivity (0.7500) and RF generates the highest values of average accuracy (0.8550), average specificity (0.9189), and average AUC (0.9073). RF is the best predictive model in the early glaucoma dataset and its mean AUC, and 95% CI is 0.9073 ± 0.0071.
According to Table 4 and Figure 1c, we can find that the model performance of MLCs also outperforms that of LGR in the moderate dataset and all of the MLCs had excellent diagnostic performance, each with a mean AUC value greater than 0.9. The model performance of CIT is lower than other MLCs. XGBoost receives the highest value of average sensitivity (0.8392) and RF generates the highest values of average accuracy (0.9327), average specificity (0.9646), and average AUC (0.9655). RF is still the best predictive model in the moderate dataset and its mean AUC, and 95% CI is 0.9655 ± 0.0058.
Table 5 and Figure 1d show that the model performance of MLCs also outperforms LGR in the severe dataset. There is not much difference in the model performance among MLCs. CIT receives the highest value of average sensitivity (0.8787) and RF generates the highest values of average accuracy (0.9536), average specificity (0.9797), and average AUC (0.9841). RF is still the best predictive model for the severe glaucoma dataset and the mean AUC, and 95% CI is 0.9841 ± 0.0044.
As the MLCs can generate promising classification performance for all three datasets and outperform the LGR model, they can be used to identify important variables for discriminating glaucomatous eyes from the normal eyes, and early, moderate, and severe glaucoma from normal conditions by ranking the importance of each variable within different classifiers. For each model, the most important variable was ranked first (i.e., 1). On the contrary, the variable with the lowest importance was ranked as the last (i.e., 114). Supplemental Tables S2–S5 show the importance ranking of each variable of each classifier for all, early, moderate, and severe datasets, respectively. Taking Supplemental Table S2 as an example, GCL_T2 is found to be the most important variable in the C5.0 model, followed by MRW_TI and cRNFL_TS. For the ranking result of the RF model, the most important area is also GCL_T2, but the second- and third-most important areas are cRNFL_G and GCL_T1, respectively. It can be seen that different classifiers can generate different variable importance ranking results at different severities of glaucoma.
In order to build a more robust variable importance ranking result by taking all the results from the MLCs into account, we average the rank value of each variable in all five MLCs. Table 6 lists the overall variable importance ranking of each variable for early, moderate, severe, and all glaucoma eyes. The averages were regarded as the mean importance of a single variable in the five MLCs. For distinguishing early glaucoma from normal eyes, the top five important predictors in order of importance are GCL_T2, GCL_T1, MRW_G, cRNFL_TS, and MRW_TI. For identifying moderate glaucoma from normal eyes, the top five important predictors in order of importance are GCL_T2, cRNFL_G, GCL_T1, MRW_G, and cRNFL_TS. For distinguishing severe glaucoma from normal eyes, the top five important predictors in order of importance are MRW_TI, cRNFL_G, GCL_I1, mRNFL_I2, and MRW_G. For discriminating all glaucoma eyes from normal eyes, the top five important predictors in order of importance are GCL_T2, GCL_T1, cRNFL_G, MRW_G, and MRW_TI.

4. Discussion

OCT has played an important role in glaucoma management, especially in early glaucoma detection. Though OCT parameters in diagnosing moderate and advanced glaucoma are of lower clinical importance, the role of OCT parameters in the evaluation of glaucoma progression is meaningful. Several studies worked on the analysis of OCT parameters in different severities of glaucoma. Mittal et al. surveyed which parameter of Cirrus and RTVue OCT has the highest ability to discriminate between early, moderate, and advanced glaucoma [52]. Ustaoglu et al. tried to determine the discriminating performance of the macular GC-IPL parameters between all the consecutive stages of glaucoma and to compare it with the discriminating performances of the RNFL and ONH parameters [53]. Chua et al. compared the diagnostic ability of macular intraretinal layer thickness with cRNFL thickness for detection of early, moderate, and advanced glaucoma [13]. Similarly, here, we tried to use machine learning methods to build reliable classifiers and study the importance of different OCT parameters in glaucoma of varying severities.
RF was demonstrated as the best or better method in other studies with similar study designs. Barella et al. analyzed cRNFL and optic nerve head parameters in SD-OCT using 10 machine learning methods and reported that RF had the best diagnostic performance among the MLCs to discriminate between normal and early to moderate glaucoma eye with an AUC of 0.877 [16]. However, the AUC obtained with RF was not significantly different from the AUC obtained with the best single OCT parameter in that study. Yoshida et al. used the RF method to analyze cRNFL, mRNFL, and ganglion cell-inner plexiform layer (GC-IPL) parameters in SD-OCT and reported that the RF method significantly improved the diagnosis of glaucoma with an AUC of 0.985 compared with using a single SD-OCT measurement [54]. Kim et al. compared four MLCs built with clinical features, cRNFL, and visual field parameters for discriminating between healthy and glaucomatous eyes, which showed that the RF classifier is the best one with an AUC of 0.979 [55]. Seo et al. investigated the diagnostic accuracy of six MLCs using BMO-MRW, cRNFL, and cRNFL color codes from SD-OCT to discriminate between early normal tension glaucoma patients from glaucoma suspects. The RF classifier was the second-best performing MLC with an AUC of 0.947, and the deep neural network model was the best one with an AUC of 0.966 [23]. These studies suggest that RF is a powerful and reliable machine learning method.
Since MLCs only use algorithms to derive prediction results from known input data, even if the inferred results are accurate, it is difficult for clinicians to understand why MLCs can produce such results. Therefore, in this study, we used the function of the “caret” package in R language to further understand how each parameter affected the classification model and try to open the “black box”. Regarding how the program evaluates the importance of the parameter, in short, if the changes of the parameter values will affect the predicted result of the classifier more, then this parameter is considered to be more important in the model’s decision. Similar methods have been used to analyze the importance of parameters in MLCs in other studies [28,30,56].
For the importance of different parameters in our models, the GCL measurements (GCL_T2, GCL_T1, GCL_I1)) in the macular ETDRS thickness map had the greatest influence in the diagnosis of early glaucoma, and BMO-MRW and cRNFL thickness were less important. This result suggested that the structural changes of the GCL were important in distinguishing early glaucoma from normal eyes in our model. Though in a previous study by Pazos et al., compared with pRNFL parameters in Spectralis OCT, macular parameters such as mRNFL, IPL, and GCL showed a lower diagnostic capacity to discriminate between healthy subjects and early glaucoma patients when used individually [12], it should be noted that when considering all the OCT parameters concurrently to build the prediction model, it was not impossible that GCL measurements contributed more because of the interaction between the parameters.
As the severity of glaucoma increased, GCL measurements (GCL_T2, GCL_T1, GCL_I1) still had a certain influence in distinguishing moderate glaucoma from normal eyes, and the ranking of cRNFL measurements (cRNFL_G, cRNFL_TS, cRNFL_TI) was significantly moved forward. This could be explained by the significant changes in cRNFL thickness compared to the normal eyes as glaucoma progressed to the moderate stage.
In the identification of severe glaucoma eye in our models, BMO-MRW, cRNFL, and GCL measurements all had a certain degree of importance, which was probably because of the obvious changes in all structures at the advanced stage of glaucoma. It was worth noting that there seemed to be a trend where BMO-MRW affected the models more because it had more values that fall into the top 10 important variables (MRW_TI, MRW_G, MRW_T, MRW_TS). In terms of distinguishing between glaucomatous and normal eyes, the GCL, BMO-MRW, and cRNFL were obvious key parameters for classification.
Neither mFT nor rFT measurements entered the top 10 in terms of importance. A possible explanation is that the full thickness provided less information for diagnosing glaucoma.
For the importance of the location of parameters, the global, temporal, inferior, superotemporal, inferotemporal sites were relatively influential locations for most of the parameters. These findings were consistent with previous research showing that glaucoma usually affects the superior and inferior temporal nerve fiber [57].
In varying severities of glaucoma, G, TS, and TI sites were all important locations of cRNFL. The TS sector was more important in early glaucoma diagnosis, and the G site is more important in advanced glaucoma. Interestingly, for BMO-MRW parameters, the G site was the more important location in discriminating both early and moderate glaucoma from normal eyes. While in the advanced stage, the importance of the TI, T, and TS sectors increased, and the TI sector was the most important location in the advanced stage. This result was consistent with previous findings proposed by McCann et al. where mean global cRNFL and TI MRW-BMO were the best parameters among all in distinguishing glaucomatous (average MD: −8.77 dB) from normal eyes [9].
For macular parameters such as GCP, IPL, and mRNFL in the ETDRS thickness map, T and I quadrants were the most important quadrants. The T quadrant was more important in the early and moderate stage, and I quadrant was more important in the advanced stage. Our result is similar to the reports presented by Choi et al. that the inferior inner macular layers were more vulnerable in advanced glaucoma [58].
Although MLCs had been proven to be excellent in helping glaucoma diagnosis by using multiple SD-OCT parameters in many studies, to our knowledge, few studies addressed how MLCs made the decisions. Yoshida et al. used the RF method, analyzing cRNFL, mRNFL, and GC-IPL measurements concurrently and obtained better diagnostic performance than that from using any single SD-OCT measurement [54]. The superior and inferotemporal mRNFL and GC-IPL measurements significantly contributed to the RF classifier in the discrimination of early glaucoma eyes from normal eyes. In another study by Oh et al., the extreme gradient boosting method was shown to be the best one for the diagnosis of glaucoma among four methods using five features coming from clinical data, visual field tests, and cRNFL parameters [28]. The mean MD of the glaucoma group was −10.24 dB. The superior quadrant and inferior quadrant of cRNFL were reported to have the strongest influence on the proposed XGboost model. Our results were similar to these two studies where GCL measurements were the most contributing variables in early glaucoma detection and the TS as well as TI sectors were the more important variables among the cRNFL parameters in detecting moderate to severe glaucoma.
There are some strengths to our study. Our research proved that MLCs can be utilized to identify glaucoma patients using OCT data with high accuracy. What is more valuable in this study is that we used MLCs to simulate how the clinicians determine which parameters are important and should be paid attention to when faced with such abundant parameters as in Spectralis OCT. By observing the ranking changes of parameters in different glaucoma stages, we may also better understand the pathophysiological mechanism of glaucoma. Moreover, papers using OCT data from Asian populations for machine learning to detect glaucoma patients are still limited. The emergence of our study can increase the diversities of relevant research and is helpful for further cross-ethnicity comparison and analysis in the future [59].
Though the results are meaningful, the present study had some limitations. First, age was significantly different between glaucoma and control groups. As age was known to be associated with RNFL loss [60], this may generate some bias in our study. Second, our study population was not large enough, which might not represent the whole population. A further larger sample is needed. Third, our research was based on the Taiwan Chinese population, and the current results might not be able to apply to other ethnic groups. Finally, the machine learning method generates models according to the input parameters of Spectralis OCT. However, when using different OCT machines with different designs or different scan protocols, the generated model is definitely different. Our models may also not be able to generate accurate predictions when using data from subjects outside our inclusion criteria. Further study by comparing different OCT machines is mandatory for further exploring this important issue in the future.

5. Conclusions

In conclusion, to our knowledge, this is one of the few studies that combine RNFL, neuroretinal rim, and macular parameters concurrently to build reliable MLCs for glaucoma diagnosis and to analyze the importance of the included parameters. Although the results are meaningful, clinicians should cautiously integrate the Spectralis OCT results into the entire clinical picture when diagnosing glaucoma.

Supplementary Materials

The following are available online at https://0-www-mdpi-com.brum.beds.ac.uk/article/10.3390/diagnostics11091718/s1, Table S1: All variables used in the machine learning classifiers, Table S2: Variable importance ranking using the five machine learning classifiers for all glaucoma eyes, Table S3: Variable importance ranking using the five machine learning classifiers for early glaucoma eyes, Table S4: Variable importance ranking using the five machine learning classifiers for moderate glaucoma eyes, Table S5: Variable importance ranking using the five machine learning classifiers for severe glaucoma eyes.

Author Contributions

Conceptualization, H.-Y.C. and C.-J.L.; methodology, C.-J.L. and S.-H.C.; software, C.-J.L. and S.-H.C.; validation, C.-J.L., S.-H.C., and H.-Y.C.; writing—original draft preparation, C.-W.W. and H.-L.S.; writing—review and editing, C.-J.L., S.-H.C., and H.-Y.C.; visualization, C.-W.W. and H.-L.S.; supervision, H.-Y.C.; project administration, H.-Y.C. and C.-J.L.; funding acquisition, H.-Y.C. All authors have read and agreed to the published version of the manuscript.

Funding

This work is supported by grants from the Fu Jen Catholic University Hospital (PL-202008002-V to H.-Y.C.).

Institutional Review Board Statement

The study was conducted according to the guidelines of the Declaration of Helsinki, and approved by the Institutional Review Board of Fu Jen Catholic University Hospital (FJUH 109020, 12 August 2020; FJUH109021, 2 September 2020).

Informed Consent Statement

Informed consent was obtained from all subjects involved in the study.

Data Availability Statement

Not applicable.

Acknowledgments

This work is supported by grants from the Fu Jen Catholic University Hospital (PL-202008002-V to H.-Y.C.) and partially supported by Ministry of Science and Technology, Taiwan (109-2221-E-030-010 to C.-J.L.). We are also thankful for the support from the teams of Wang YK in the Department of Electrical Engineering of Fu Jen Catholic University with the data acquisition.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Weinreb, R.N.; Aung, T.; Medeiros, F.A. The pathophysiology and treatment of glaucoma: A review. JAMA 2014, 311, 1901–1911. [Google Scholar] [CrossRef] [Green Version]
  2. Medeiros, F.A.; Zangwill, L.M.; Bowd, C.; Vessani, R.M.; Susanna, R., Jr.; Weinreb, R.N. Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography. Am. J. Ophthalmol. 2005, 139, 44–55. [Google Scholar] [CrossRef] [PubMed]
  3. Langenegger, S.J.; Funk, J.; Toteberg-Harms, M. Reproducibility of retinal nerve fiber layer thickness measurements using the eye tracker and the retest function of Spectralis SD-OCT in glaucomatous and healthy control eyes. Investig. Ophthalmol. Vis. Sci. 2011, 52, 3338–3344. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  4. Ghasia, F.F.; El-Dairi, M.; Freedman, S.F.; Rajani, A.; Asrani, S. Reproducibility of spectral-domain optical coherence tomography measurements in adult and pediatric glaucoma. J. Glaucoma 2015, 24, 55–63. [Google Scholar] [CrossRef] [PubMed]
  5. Kamal, D.S.; Viswanathan, A.C.; Garway-Heath, D.F.; Hitchings, R.A.; Poinoosawmy, D.; Bunce, C. Detection of optic disc change with the Heidelberg retina tomograph before confirmed visual field change in ocular hypertensives converting to early glaucoma. Br. J. Ophthalmol. 1999, 83, 290–294. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  6. Mwanza, J.C.; Warren, J.L.; Budenz, D.L. Utility of combining spectral domain optical coherence tomography structural parameters for the diagnosis of early Glaucoma: A mini-review. Eye Vis. 2018, 5, 9. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  7. Michelessi, M.; Riva, I.; Martini, E.; Figus, M.; Frezzotti, P.; Agnifili, L.; Manni, G.; Quaranta, L.; Miglior, S.; Posarelli, C.; et al. Macular versus nerve fibre layer versus optic nerve head imaging for diagnosing glaucoma at different stages of the disease: Multicenter Italian Glaucoma Imaging Study. Acta Ophthalmol. 2019, 97, e207–e215. [Google Scholar] [CrossRef] [PubMed]
  8. Wu, H.; de Boer, J.F.; Chen, T.C. Diagnostic capability of spectral-domain optical coherence tomography for glaucoma. Am. J. Ophthalmol. 2012, 153, 815–826.e812. [Google Scholar] [CrossRef] [Green Version]
  9. McCann, P.; Hogg, R.E.; Wright, D.M.; McGuinness, B.; Young, I.S.; Kee, F.; Azuara-Blanco, A. Diagnostic Accuracy of Spectral-Domain OCT Circumpapillary, Optic Nerve Head, and Macular Parameters in the Detection of Perimetric Glaucoma. Ophthalmol. Glaucoma 2019, 2, 336–345. [Google Scholar] [CrossRef]
  10. Li, R.; Wang, X.; Wei, Y.; Fang, Y.; Tian, T.; Kang, L.; Li, M.; Cai, Y.; Pan, Y. Diagnostic capability of different morphological parameters for primary open-angle glaucoma in the Chinese population. BMC Ophthalmol. 2021, 21, 151. [Google Scholar] [CrossRef]
  11. Cifuentes-Canorea, P.; Ruiz-Medrano, J.; Gutierrez-Bonet, R.; Pena-Garcia, P.; Saenz-Frances, F.; Garcia-Feijoo, J.; Martinez-de-la-Casa, J.M. Analysis of inner and outer retinal layers using spectral domain optical coherence tomography automated segmentation software in ocular hypertensive and glaucoma patients. PLoS ONE 2018, 13, e0196112. [Google Scholar] [CrossRef] [Green Version]
  12. Pazos, M.; Dyrda, A.A.; Biarnes, M.; Gomez, A.; Martin, C.; Mora, C.; Fatti, G.; Anton, A. Diagnostic Accuracy of Spectralis SD OCT Automated Macular Layers Segmentation to Discriminate Normal from Early Glaucomatous Eyes. Ophthalmology 2017, 124, 1218–1228. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  13. Chua, J.; Tan, B.; Ke, M.; Schwarzhans, F.; Vass, C.; Wong, D.; Nongpiur, M.E.; Wei Chua, M.C.; Yao, X.; Cheng, C.Y.; et al. Diagnostic Ability of Individual Macular Layers by Spectral-Domain OCT in Different Stages of Glaucoma. Ophthalmol. Glaucoma 2020, 3, 314–326. [Google Scholar] [CrossRef]
  14. Kononenko, I. Machine learning for medical diagnosis: History, state of the art and perspective. Artif. Intell. Med. 2001, 23, 89–109. [Google Scholar] [CrossRef] [Green Version]
  15. Silva, F.R.; Vidotti, V.G.; Cremasco, F.; Dias, M.; Gomi, E.S.; Costa, V.P. Sensitivity and specificity of machine learning classifiers for glaucoma diagnosis using Spectral Domain OCT and standard automated perimetry. Arq. Bras. Oftalmol. 2013, 76, 170–174. [Google Scholar] [CrossRef] [Green Version]
  16. Barella, K.A.; Costa, V.P.; Goncalves Vidotti, V.; Silva, F.R.; Dias, M.; Gomi, E.S. Glaucoma Diagnostic Accuracy of Machine Learning Classifiers Using Retinal Nerve Fiber Layer and Optic Nerve Data from SD-OCT. J. Ophthalmol. 2013, 2013, 789129. [Google Scholar] [CrossRef]
  17. Burgansky-Eliash, Z.; Wollstein, G.; Chu, T.; Ramsey, J.D.; Glymour, C.; Noecker, R.J.; Ishikawa, H.; Schuman, J.S. Optical coherence tomography machine learning classifiers for glaucoma detection: A preliminary study. Investig. Ophthalmol. Vis. Sci. 2005, 46, 4147–4152. [Google Scholar] [CrossRef] [Green Version]
  18. Huang, M.L.; Chen, H.Y. Development and comparison of automated classifiers for glaucoma diagnosis using Stratus optical coherence tomography. Investig. Ophthalmol. Vis. Sci. 2005, 46, 4121–4129. [Google Scholar] [CrossRef]
  19. Bizios, D.; Heijl, A.; Hougaard, J.L.; Bengtsson, B. Machine learning classifiers for glaucoma diagnosis based on classification of retinal nerve fibre layer thickness parameters measured by Stratus OCT. Acta Ophthalmol. 2010, 88, 44–52. [Google Scholar] [CrossRef] [PubMed]
  20. Baskaran, M.; Ong, E.L.; Li, J.L.; Cheung, C.Y.; Chen, D.; Perera, S.A.; Ho, C.L.; Zheng, Y.F.; Aung, T. Classification algorithms enhance the discrimination of glaucoma from normal eyes using high-definition optical coherence tomography. Investig. Ophthalmol. Vis. Sci. 2012, 53, 2314–2320. [Google Scholar] [CrossRef] [Green Version]
  21. Blumberg, D.M.; Dale, E.; Pensec, N.; Cioffi, G.A.; Radcliffe, N.; Pham, M.; Al-Aswad, L.; Reynolds, M.; Ciarleglio, A. Discrimination of Glaucoma Patients From Healthy Individuals Using Combined Parameters From Spectral-domain Optical Coherence Tomography in an African American Population. J. Glaucoma 2016, 25, e196–e203. [Google Scholar] [CrossRef]
  22. Park, K.; Kim, J.; Lee, J. The Relationship Between Bruch’s Membrane Opening-Minimum Rim Width and Retinal Nerve Fiber Layer Thickness and a New Index Using a Neural Network. Transl. Vis. Sci. Technol. 2018, 7, 14. [Google Scholar] [CrossRef] [Green Version]
  23. Seo, S.B.; Cho, H.K. Deep learning classification of early normal-tension glaucoma and glaucoma suspects using Bruch’s membrane opening-minimum rim width and RNFL. Sci. Rep. 2020, 10, 19042. [Google Scholar] [CrossRef]
  24. Fernandez Escamez, C.S.; Martin Giral, E.; Perucho Martinez, S.; Toledano Fernandez, N. High interpretable machine learning classifier for early glaucoma diagnosis. Int. J. Ophthalmol. 2021, 14, 393–398. [Google Scholar] [CrossRef]
  25. Ting, D.S.W.; Pasquale, L.R.; Peng, L.; Campbell, J.P.; Lee, A.Y.; Raman, R.; Tan, G.S.W.; Schmetterer, L.; Keane, P.A.; Wong, T.Y. Artificial intelligence and deep learning in ophthalmology. Br. J. Ophthalmol. 2019, 103, 167–175. [Google Scholar] [CrossRef] [Green Version]
  26. Ahuja, A.S.; Halperin, L.S. Understanding the advent of artificial intelligence in ophthalmology. J. Curr. Ophthalmol. 2019, 31, 115–117. [Google Scholar] [CrossRef]
  27. Yousefi, S.; Pasquale, L.R.; Boland, M.V. Artificial Intelligence and Glaucoma: Illuminating the Black Box. Ophthalmol. Glaucoma 2020, 3, 311–313. [Google Scholar] [CrossRef]
  28. Oh, S.; Park, Y.; Cho, K.J.; Kim, S.J. Explainable Machine Learning Model for Glaucoma Diagnosis and Its Interpretation. Diagnostics 2021, 11, 510. [Google Scholar] [CrossRef]
  29. Mehta, P.; Petersen, C.A.; Wen, J.C.; Banitt, M.R.; Chen, P.P.; Bojikian, K.D.; Egan, C.; Lee, S.I.; Balazinska, M.; Lee, A.Y.; et al. Automated detection of glaucoma with interpretable machine learning using clinical data and multi-modal retinal images. Am. J. Ophthalmol. 2021. [Google Scholar] [CrossRef]
  30. Wu, T.E.; Chen, H.A.; Jhou, M.J.; Chen, Y.N.; Chang, T.J.; Lu, C.J. Evaluating the Effect of Topical Atropine Use for Myopia Control on Intraocular Pressure by Using Machine Learning. J. Clin. Med. 2020, 10, 111. [Google Scholar] [CrossRef]
  31. Jonas, J.B.; Budde, W.M.; Panda-Jonas, S. Ophthalmoscopic evaluation of the optic nerve head. Surv. Ophthalmol. 1999, 43, 293–320. [Google Scholar] [CrossRef]
  32. Keltner, J.L.; Johnson, C.A.; Cello, K.E.; Edwards, M.A.; Bandermann, S.E.; Kass, M.A.; Gordon, M.O.; Ocular Hypertension Treatment Study Group. Classification of visual field abnormalities in the ocular hypertension treatment study. Arch. Ophthalmol. 2003, 121, 643–650. [Google Scholar] [CrossRef]
  33. Caprioli, J.; Park, H.J.; Ugurlu, S.; Hoffman, D. Slope of the peripapillary nerve fiber layer surface in glaucoma. Investig. Ophthalmol. Vis. Sci. 1998, 39, 2321–2328. [Google Scholar] [CrossRef]
  34. Hodapp, E.; Parrish, R.K.; Anderson, D.R. Clinical Decisions in Glaucoma; The CV Mosby Co: St Louis, MO, USA, 1993; pp. 52–61. [Google Scholar]
  35. Sufriyana, H.; Husnayain, A.; Chen, Y.L.; Kuo, C.Y.; Singh, O.; Yeh, T.Y.; Wu, Y.W.; Su, E.C. Comparison of Multivariable Logistic Regression and Other Machine Learning Algorithms for Prognostic Prediction Studies in Pregnancy Care: Systematic Review and Meta-Analysis. JMIR Med. Inform. 2020, 8, e16503. [Google Scholar] [CrossRef]
  36. Ting, W.-C.; Chang, H.-R.; Chang, C.-C.; Lu, C.-J. Developing a Novel Machine Learning-Based Classification Scheme for Predicting SPCs in Colorectal Cancer Survivors. Appl. Sci. 2020, 10, 1355. [Google Scholar] [CrossRef] [Green Version]
  37. Shih, C.C.; Lu, C.J.; Chen, G.D.; Chang, C.C. Risk Prediction for Early Chronic Kidney Disease: Results from an Adult Health Examination Program of 19,270 Individuals. Int. J. Environ. Res. Public Health 2020, 17, 4973. [Google Scholar] [CrossRef]
  38. Huang, Y.C.; Li, S.J.; Chen, M.; Lee, T.S.; Chien, Y.N. Machine-Learning Techniques for Feature Selection and Prediction of Mortality in Elderly CABG Patients. Healthcare 2021, 9, 547. [Google Scholar] [CrossRef]
  39. Hothorn, T.; Hornik, K.; Zeileis, A. Unbiased Recursive Partitioning: A Conditional Inference Framework. J. Comput. Graph. Stat. 2006, 15, 651–674. [Google Scholar] [CrossRef] [Green Version]
  40. Landwehr, N.; Hall, M.; Frank, E. Logistic model trees. Mach. Learn. 2005, 59, 161–205. [Google Scholar] [CrossRef] [Green Version]
  41. Quinlan, J.R.C. Programs for Machine Learning; Morgan Kaufmann Publishers: Burlington, MA, USA, 1993. [Google Scholar]
  42. Breiman, L. Random forests. Mach. Learn. 2001, 45, 5–32. [Google Scholar] [CrossRef] [Green Version]
  43. Chen, T.; Guestrin, C. XGBoost: A Scalable Tree Boosting System. In Proceedings of the 22nd ACM SIGKDD International Conference on Knowledge Discovery and Data Mining, San Francisco, CA, USA, 13–17 August 2016; pp. 785–794. [Google Scholar]
  44. Hebbali, A. blorr: Tools for Developing Binary Logistic Regression Models, R Package Version 0.3.0. Available online: https://CRAN.R-project.org/package=blorr (accessed on 5 June 2021).
  45. Hothorn, T.; Seibold, H.; Zeileis, A. partykit: A Toolkit for Recursive Partytioning, R Package Version 1.2-13. Available online: https://CRAN.R-project.org/package=partykit (accessed on 5 June 2021).
  46. Hornik, K.; Buchta, C.; Hothorn, T.; Karatzoglou, A.; Meyer, D.; Zeileis, A. RWeka: R/Weka Interface, R Package Version 0.4-43. Available online: https://CRAN.R-project.org/package=RWeka (accessed on 5 June 2021).
  47. Kuhn, M.; Weston, S.; Culp, M.; Coulter, N.; Quinlan, R. C50: C5.0 Decision Trees and Rule-Based Models. R Package Version 0.1.5. Available online: https://CRAN.R-project.org/package=C50 (accessed on 5 June 2021).
  48. Liaw, A.; Wiener, M. randomForest: Breiman and Cutler’s Random Forests for Classification and Regression. R Package Version, 4.6.14. Available online: https://CRAN.R-project.org/package=randomForest (accessed on 5 June 2021).
  49. Chen, T.; He, T.; Benesty, M.; Khotilovich, V.; Tang, Y.; Cho, H.; Chen, K.; Mitchell, R.; Cano, I.; Zhou, T.; et al. Xgboost: Extreme Gradient Boosting. 2021. R Package Version 1.4.1.1. Available online: https://CRAN.R-project.org/package=xgboost (accessed on 5 June 2021).
  50. Kuhn, M. Caret: Classification and Regression Training. 2021. R Package Version, 6.0-88. Available online: https://CRAN.R-project.org/package=caret (accessed on 5 June 2021).
  51. Nogueira, S.; Sechidis, K.; Brown, G. On the use of Spearman’s rho to measure the stability of feature rankings. Lect. Notes Comput. Sci. 2017, 10255, 381–391. [Google Scholar] [CrossRef]
  52. Mittal, D.; Dubey, S.; Gandhi, M.; Pegu, J.; Bhoot, M.; Gupta, Y.P. Discriminating ability of Cirrus and RTVue optical coherence tomography in different stages of glaucoma. Indian J. Ophthalmol. 2018, 66, 675–680. [Google Scholar] [CrossRef]
  53. Ustaoglu, M.; Solmaz, N.; Onder, F. Discriminating performance of macular ganglion cell-inner plexiform layer thicknesses at different stages of glaucoma. Int. J. Ophthalmol. 2019, 12, 464–471. [Google Scholar] [CrossRef] [PubMed]
  54. Yoshida, T.; Iwase, A.; Hirasawa, H.; Murata, H.; Mayama, C.; Araie, M.; Asaoka, R. Discriminating between glaucoma and normal eyes using optical coherence tomography and the ‘Random Forests’ classifier. PLoS ONE 2014, 9, e106117. [Google Scholar] [CrossRef]
  55. Kim, S.J.; Cho, K.J.; Oh, S. Development of machine learning models for diagnosis of glaucoma. PLoS ONE 2017, 12, e0177726. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  56. Machado, G.; Mendoza, M.R.; Corbellini, L.G. What variables are important in predicting bovine viral diarrhea virus? A random forest approach. Vet. Res. 2015, 46, 85. [Google Scholar] [CrossRef] [Green Version]
  57. Quigley, H.A.; Addicks, E.M.; Green, W.R. Optic nerve damage in human glaucoma. III. Quantitative correlation of nerve fiber loss and visual field defect in glaucoma, ischemic neuropathy, papilledema, and toxic neuropathy. Arch. Ophthalmol. 1982, 100, 135–146. [Google Scholar] [CrossRef]
  58. Choi, J.A.; Shin, H.Y.; Park, H.L.; Park, C.K. The Pattern of Retinal Nerve Fiber Layer and Macular Ganglion Cell-Inner Plexiform Layer Thickness Changes in Glaucoma. J. Ophthalmol. 2017, 2017, 6078365. [Google Scholar] [CrossRef] [Green Version]
  59. Sekimitsu, S.; Zebardast, N. Glaucoma and Machine Learning: A Call for Increased Diversity in Data. Ophthalmol. Glaucoma 2021, 4, 339–342. [Google Scholar] [CrossRef]
  60. Demirkaya, N.; van Dijk, H.W.; van Schuppen, S.M.; Abramoff, M.D.; Garvin, M.K.; Sonka, M.; Schlingemann, R.O.; Verbraak, F.D. Effect of age on individual retinal layer thickness in normal eyes as measured with spectral-domain optical coherence tomography. Investig. Ophthalmol. Vis. Sci. 2013, 54, 4934–4940. [Google Scholar] [CrossRef]
Figure 1. ROC curves of all classifiers for (a) all, (b) early, (c) moderate, and (d) severe glaucoma eyes.
Figure 1. ROC curves of all classifiers for (a) all, (b) early, (c) moderate, and (d) severe glaucoma eyes.
Diagnostics 11 01718 g001aDiagnostics 11 01718 g001b
Table 1. Demographics and clinical characteristics of the study groups.
Table 1. Demographics and clinical characteristics of the study groups.
CharacteristicsNormal Eye
(n = 224)
Glaucomatous Eye
(n = 246)
Mean ± SDMean ± SDp *
Persons114151-
Age (year)53.9 ± 16.061.2 ± 12.3<0.001
Gender (male/female) 41/7383/680.003
BCVA0.96 ± 0.090.91 ± 0.11<0.001
IOP14.1 ± 3.314.5 ± 2.60.230
SE (D)−1.13 ± 2.17−1.10 ± 2.160.801
Early Stage
(n = 114)
Moderate Stage
(n = 61)
Severe Stage
(n = 71)
Mean ± SDp *Mean ± SDp *Mean ± SDp *
BCVA0.96 ± 0.090.91 ± 0.11<0.0010.90 ± 0.11<0.0010.91 ± 0.11<0.001
IOP14.1 ± 3.314.8 ± 2.60.06613.8 ± 2.60.40514.5 ± 2.50.279
SE (D)−1.13 ± 2.17−1.17 ± 2.230.787−1.16 ± 2.320.697−0.72 ± 2.520.748
MD (dB)−0.82 ± 1.32−3.79 ± 1.10<0.001−8.31 ± 1.61<0.001−19.01 ± 5.49<0.001
PSD (dB)2.20 ± 1.294.38 ± 2.08<0.0018.87 ± 3.43<0.00111.40 ± 2.97<0.001
BCVA: best-corrected visual acuity; IOP: intraocular pressure; SE: spherical equivalent; D: diopters; MD: mean deviation; PSD: pattern standard deviation. p *: level of statistical significance in comparison between groups using the Mann–Whitney U test (except for eye, gender, Chi-square). Bold text indicates statistically significant results (p < 0.05).
Table 2. Model performance of all methods for all glaucoma eyes.
Table 2. Model performance of all methods for all glaucoma eyes.
MethodsAccuracy
Mean (SD)
Sensitivity
Mean (SD)
Specificity
Mean (SD)
AUC
Mean (SD)
LGR0.7418
(0.03)
0.7479
(0.05)
0.7363
(0.05)
0.7788
(0.03)
CIT0.8208
(0.04)
0.8507
(0.07)
0.7939
(0.07)
0.8866
(0.04)
LMT0.8491
(0.04)
0.8825
(0.05)
0.8192
(0.06)
0.9127
(0.03)
C50.8709
(0.03)
0.8979
(0.05)
0.8468
(0.06)
0.9403
(0.02)
RF0.8818
(0.03)
0.9166
(0.04)
0.8507
(0.06)
0.9459
(0.02)
XGBOOST0.8639
(0.03)
0.8982
(0.05)
0.8331
(0.06)
0.9275
(0.03)
LGR: logistic regression; CIT: conditional inference tree; LMT: logistic model tree; RF: random forest; XGBOOST: extreme gradient boosting; AUC: area under the receiver operating characteristic (roc) curve.
Table 3. Model performance of all methods for early glaucoma eyes.
Table 3. Model performance of all methods for early glaucoma eyes.
MethodsAccuracy
Mean (SD)
Sensitivity
Mean (SD)
Specificity
Mean (SD)
AUC
Mean (SD)
LGR0.6916
(0.05)
0.5859
(0.11)
0.7442
(0.07)
0.6860
(0.06)
CIT0.7729
(0.05)
0.7286
(0.10)
0.7950
(0.08)
0.8156
(0.06)
LMT0.8006
(0.05)
0.6990
(0.09)
0.8514
(0.06)
0.8116
(0.06)
C50.8408
(0.04)
0.7041
(0.09)
0.9091
(0.05)
0.8927
(0.04)
RF0.8550
(0.04)
0.7272
(0.08)
0.9189
(0.04)
0.9073
(0.04)
XGBOOST0.8433
(0.04)
0.7500
(0.10)
0.8901
(0.05)
0.8852
(0.04)
LGR: logistic regression; CIT: conditional inference tree; LMT: logistic model tree; RF: random forest; XGBOOST: extreme gradient boosting; AUC: area under the receiver operating characteristic (roc) curve.
Table 4. Model performance of all methods for moderate glaucoma eyes.
Table 4. Model performance of all methods for moderate glaucoma eyes.
MethodsAccuracy
Mean (SD)
Sensitivity
Mean (SD)
Specificity
Mean (SD)
AUC
Mean (SD)
LGR0.8287
(0.05)
0.6625
(0.12)
0.8748
(0.06)
0.8187
(0.07)
CIT0.8861
(0.05)
0.8175
(0.11)
0.9047
(0.06)
0.9035
(0.05)
LMT0.9225
(0.04)
0.8008
(0.13)
0.9557
(0.04)
0.9553
(0.04)
C50.9200
(0.03)
0.7809
(0.12)
0.9580
(0.03)
0.9529
(0.04)
RF0.9327
(0.03)
0.8159
(0.12)
0.9646
(0.03)
0.9655
(0.03)
XGBOOST0.9293
(0.03)
0.8392
(0.12)
0.9540
(0.03)
0.9549
(0.04)
LGR: logistic regression; CIT: conditional inference trees; LMT: logistic model tree); RF: random forest; XGBOOST: extreme gradient boosting; AUC: area under the receiver operating characteristic (roc) curve.
Table 5. Model performance of all methods for severe glaucoma eyes.
Table 5. Model performance of all methods for severe glaucoma eyes.
MethodsAccuracy
Mean (SD)
Sensitivity
Mean (SD)
Specificity
Mean (SD)
AUC
Mean (SD)
LGR0.8714
(0.04)
0.7700
(0.11)
0.9031
(0.05)
0.9017
(0.05)
CIT0.9219
(0.04)
0.8787
(0.09)
0.9358
(0.05)
0.9416
(0.05)
LMT0.9367
(0.03)
0.8580
(0.09)
0.9619
(0.03)
0.9592
(0.04)
C50.9516
(0.03)
0.8687
(0.09)
0.9779
(0.03)
0.9757
(0.03)
RF0.9536
(0.02)
0.8737
(0.08)
0.9791
(0.02)
0.9841
(0.02)
XGBOOST0.9393
(0.03)
0.8651
(0.09)
0.9630
(0.03)
0.9742
(0.03)
LGR: logistic regression; CIT: conditional inference trees; LMT: logistic model tree); RF: random forest; XGBOOST: extreme gradient boosting; AUC: area under the receiver operating characteristic (roc) curve.
Table 6. Overall variable importance ranking for early, moderate, severe, and all glaucoma eyes (only the first 10 important variables shown).
Table 6. Overall variable importance ranking for early, moderate, severe, and all glaucoma eyes (only the first 10 important variables shown).
EarlyModerateSevereAll
RankVariable
Name
Average
Rank
Variable
Name
Average
Rank
Variable
Name
Average
Rank
Variable
Name
Average
Rank
1GCL_T21.0GCL_T21.8MRW_TI2.0GCL_T21.8
2GCL_T13.4cRNFL_G2.0cRNFL_G3.0GCL_T13.6
3MRW_G4.6GCL_T13.0GCL_I13.6cRNFL_G3.8
4cRNFL_TS4.8MRW_G5.6mRNFL_I24.6MRW_G5.2
5MRW_TI5.6cRNFL_TS5.8MRW_G5.8MRW_TI5.2
6cRNFL_G5.8GCL_I17.2cRNFL_TI8.0GCL_I15.6
7GCL_I17.4cRNFL_TI8.0MRW_T8.6cRNFL_TS5.6
8IPL_T110.2IPL_T29.8MRW_TS10.0cRNFL_TI10.6
9MRW_N12.8mRNFL_I29.8GCL_T110.6MRW_NI13.4
10MRW_TS13.0MRW_N11.8cRNFL_TS11.4MRW_N13.6
cRNFL: circumpapillary retinal nerve fiber layer; BMO-MRW: Bruch’s membrane opening opening-minimal rim width; mRNFL: macular retinal nerve fiber layer; GCL: ganglion cell layer; IPL: inner plexiform layer; T: temporal; TI: inferotemporal; N: nasal; TS: superotemporal; G: global; I: inferior. Note: These variables are colored according to the parameters to facilitate understanding of their changes (red: EDTRS macular thickness map, green: cRNFL, blue: BMO-MRW).
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Wu, C.-W.; Shen, H.-L.; Lu, C.-J.; Chen, S.-H.; Chen, H.-Y. Comparison of Different Machine Learning Classifiers for Glaucoma Diagnosis Based on Spectralis OCT. Diagnostics 2021, 11, 1718. https://0-doi-org.brum.beds.ac.uk/10.3390/diagnostics11091718

AMA Style

Wu C-W, Shen H-L, Lu C-J, Chen S-H, Chen H-Y. Comparison of Different Machine Learning Classifiers for Glaucoma Diagnosis Based on Spectralis OCT. Diagnostics. 2021; 11(9):1718. https://0-doi-org.brum.beds.ac.uk/10.3390/diagnostics11091718

Chicago/Turabian Style

Wu, Chao-Wei, Hsiang-Li Shen, Chi-Jie Lu, Ssu-Han Chen, and Hsin-Yi Chen. 2021. "Comparison of Different Machine Learning Classifiers for Glaucoma Diagnosis Based on Spectralis OCT" Diagnostics 11, no. 9: 1718. https://0-doi-org.brum.beds.ac.uk/10.3390/diagnostics11091718

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop