Next Article in Journal
BN-RA: A Hybrid Model for Risk Analysis of Overload-Induced Early Cable Fires
Next Article in Special Issue
Comparison of Casein Phosphopeptide with Potassium Nitrate and Sodium Monofluorophosphate Desensitizing Efficacy after In-Office Vital Bleaching—A Randomized Trial
Previous Article in Journal
Fresh State, Rheological and Microstructural Characteristics of Alkali-Activated Mortars Developed Using Novel Dry Mixing Technique under Ambient Conditions
Previous Article in Special Issue
High-Grade B-Cell Lymphoma Not Otherwise Specified (HGBL, NOS) in the Maxillary Sinus Mimicking Periapical Inflammation: Case Report and Review of the Literature
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Research on the Mechanical Properties, Fluoride and Monomer Release of a New Experimental Flowable Giomer in Comparison to Three Commercial Flowable Giomers

1
Department of Conservative Odontology, Iuliu Hatieganu University of Medicine and Pharmacy, 33 Motilor Street, 400001 Cluj-Napoca, Romania
2
Department of Polymer Composites, Babeş-Bolyai University, Raluca Ripan Institute for Research in Chemistry, 30 Fantanele Street, 400294 Cluj-Napoca, Romania
3
Department of Prosthetic Dentistry and Dental Materials, Iuliu Hatieganu University of Medicine and Pharmacy, 32 Clinicilor Street, 400006 Cluj-Napoca, Romania
*
Author to whom correspondence should be addressed.
Submission received: 1 September 2021 / Revised: 20 September 2021 / Accepted: 21 September 2021 / Published: 24 September 2021
(This article belongs to the Special Issue Clinical Applications for Dentistry and Oral Health)

Abstract

:
Giomers are hybrid dental materials with controlled fluoride release properties. The aim of this study was to characterise a new experimental flowable giomer (G) in comparison to three commercial flowable giomers: Beautifil flow Plus X F00 (B-F00), Beautifil flow F02 (B-F02) and Beautifil flow Plus X F03 (B-F03), Shofu, Kyoto, Japan. The studied properties are fluoride ion release, residual monomers release and mechanical properties. The data analysis was performed using the ANOVA test and Tukey test for post hoc comparisons between groups. During the first day of the fluoride releasing measurement, the following classification resulted: B-F02 ˃ B-F03 ˃ B-F00 ˃ G and at the end of the investigation period, at 60 days: B-F02 ˃ B-F03 ˃ G ˃ B-F00. The experimental giomer released a lower percentage of total residual monomers than the commercial giomers. The highest value for the mechanical properties was recorded for the commercial giomers. The experimental giomer registered the lowest values for mechanical properties but higher than the imposed standard limit. There were statistically significant differences between the analyzed materials, in terms of fluoride releasing, residual monomer releasing and mechanical properties.

1. Introduction

The necessity of restorative materials for different clinical situations was responsible for the development of new versions among which the flowable materials play an important role. Resin based flowable materials are characterized by low viscosity and high elasticity, properties that make them highly recommended for the restoration of complex and difficult areas like the cervical portion of a tooth or the marginal ridges [1,2]. Recently developed flowable materials are reported to have superior mechanical properties and wear resistance, making them applicable in a wide variety of restorative cases, some of them with mechanical properties similar to conventional resin matrix based restoratives [3,4,5].
Giomers represent a new development in the hybrid material category and consist in a stable glass-ionomer faze, on a glass core resulted from an acid-base reaction between fluoridated glass and poly-carboxylic acid, in the presence of water (“Pre-Reacted Glass-ionomer filler” or PRG). This material is proven to have anti-plaque effect, reducing the adherence of harmful bacteria to the tooth structure, is adequate for the treatment of hypersensitivity and non-cytotoxic to human teeth [6]. Appling PRG-technology to the filler in resin based composite materials gives them bioactive properties through fluoride release and recharge, similar to traditional glass-ionomers, but maintaining in the same time physical and esthetical properties of the composites [7,8].
Flowable materials in the form of giomers have very specific clinical indications in the field of restorative dentistry, because of their flexibility and quality of adhesion to enamel and dentine [9].
Flowable giomers have a several applications in the practical field, in function with the filler percentage. The higher filler percentage and strong mechanical properties of B-F00, makes it able to withstand the restoration of occlusal anatomy, class V restorations and marginal ridges, where the highest forces are applied. A lower filler percentage and lower mechanical properties, but higher fluidity and wettability make B-F03 indicated for class V restorations, small fillings or as cavity liner, where the ability of a filling material to flow and fill all details are most important [10]. The B-F02 material with lower mechanical properties and lower filler percentage, make it suitable for small or superficial restorations (class I to III and class V) and also as cavity liner [10].
To the best of our knowledge, very few references are available in literature regarding these materials [11,12,13]. Giomers were characterized regarding optical properties, translucency and masking capacity [12], water sorption and solubility [11,13].
Bioactive materials bring benefits regarding carious protection trough fluoride release. The capacity to release a protective amount of fluoride is dependent on the hydric degradation of the incorporated bioactive glass. However, the interaction with oral fluids has consequences on the mechanical properties of a material and on the surface roughness [14]. Similar to glass-ionomers, giomers act like fluoride reservoirs, with the initial high concentration release phase lasting 24–48 h. This value will decrease over time, reaching a stable point in 3 to 5 weeks after application [7,15]. Clinically, the most important aspect regarding fluoride release is the limitation of secondary caries, the main cause for direct restoration early replacement [16,17,18,19,20]. The PRG-filler (pre-reacted glass filler) technology proved effective against bacteria responsible for caries apparition, including Streptoccocus Mutans [17,21,22].
The fluoride recharging capacity form the oral environment of giomer materials can benefit from the application of gels, varnishes, usage of fluoridated mouth wash or tooth paste. [20,21,22,23]. Over time, the quantity of fluoride released into the oral environment will decrease, resulting in porous defects in the resin matrix [20,23]. The most effective method for enamel remineralization and incipient caries remineralisation, at the present time, is through the local application of fluoride [24].
Any cured composite, including the giomer variation, has some degree of unreacted monomers trapped inside the matrix. The degree of conversion of a composite based material is important when determining its biocompatibility. Depending on the monomers in the composition of the material, the elution of residual monomers is different. The factors that influence the conversion degree are the photo-polymerization conditions and the quantity of photo-initiator. All interaction with oral fluids and specific filler percentage inside the resin matrix will have an impact on the mechanical properties of bioactive restorative materials [25].
The objective of the present study is to create a detailed comparison between an experimental flowable giomer produced by the chemistry laboratory at Babeş Bolyai University in Cluj-Napoca and three commercial flowable giomers from Shofu Inc. Kyoto, Japan, regarding fluoride release, residual monomers, and mechanical properties. All of the materials included in the study have the same polymeric matrix: Bis-GMA/TEGDMA (2,2-Bis[p-(2-hydroxy-3-methacryloyloxypropoxy)-phenyl]-propane/triethylene glycol dimethacrylate) and different fillers in different percentages.
The null hypothesis is that no statistically significant difference can be found between the analyzed materials, regarding fluoride release, residual monomer and mechanical properties.

2. Materials and Methods

2.1. Studied Materials

For this study we chose the following commercial materials: Beautifil Flow F02, Beautifil Flow Plus X F00, Beautifil Flow X F03 (from manufacturers’ instructions—Shofu Inc. Kyoto, Dental Corporation, Japan) and the experimental giomer obtained at Babeș-Bolyai University, Raluca Ripan Institute for Research in Chemistry, (Cluj-Napoca, Romania). Table 1 contains the composition of the materials investigated.
For of the experimental giomer, monomer-Bis-GMA analog (93% 2,2-Bis [p-(2-hydroxy-3-methacryloyloxypropoxy)-phenyl]-propane monomer and 7% dimer, obtained at Babeș-Bolyai University, Raluca Ripan Institute of Chemistry Research (Cluj-Napoca, Romania) was used as base in the polymer matrix [14]. As a diluting monomer triethylene glycol dimethacrylate (TEGDMA) was used; the photochemical initiation system had the following components: 0.5% camphorquinone (CQ) as the photosensitizer and 1% dimethylaminoethyl-methacrylate (DMAEM) as the accelerator; all from Sigma Aldrich Chemical Co. (Taufkirchen, Germany). Experimental glass powder (Exp-Glass), fluoro-hydroxyapatite (FHAP) and pre-reacted glass (SPRG) were also synthesized in the UBB-ICCRR laboratory. Exp-Glass was silanized with 3-methacrylyloxypropyl-1-trimethoxy-silane (A-174 silane) from Aldrich. Methods for obtaining and the characterization of the inorganic filler components are presented in literature [25,26].

2.2. Characteristics Investigated for the Selected Materials

2.2.1. Fluoride Release

For this experiment, a number of 5 samples (1mm thickness, 15 mm in diameter) were prepared from each material. The light curing was performed for 20 s with a LED.E (GuilinWoodpecker Medical Instruments Co., Guangxi, China), having the wavelength in the range of 470 nm and the intensity of 950 mW cm. The samples were placed in 45 mL of distilled water and 5 mL of TISAB III buffer (total ionic strength adjustment buffer, concentrated solution, HI 4010-06, Hanna Instruments, Woonsocket, RI, USA) at 37 °C. The specific measurements were performed daily for the first 7 days of the experiment, and then on the 14th, 21st, 30th and 60th days. After each determination, each sample was placed in the same polyethylene container and the temperature was kept constant at 37 °C with a thermostatic bath [26].
The fluoride ion releasing analysis was performed with the use of a selective electrode (Combination Fluoride Electrode HI 4110 filled with HI 7075 electrolyte for the reference electrode from Hanna instruments). The electrode was previously calibrated, with standardized solutions with concentrations varying between 10−5–10−2 mol/L F-. All measurements, both for the investigated and the standardized solutions were performed in 50 mL of distilled water and TISAB III buffer solutions (45:5) at 37 °C (±2). Fluoride release was reported in ppm.

2.2.2. HPLC Determination of Residual Monomers

Samples Preparation

After 60 days, the storage medium (distilled water/TISAB III) in which the samples were immersed in order to perform the fluoride release assessment, was frozen and then lyophilized in a Model Alpha 1-4 LDPLUS until the liquid was completely removed. The residual monomers from restoration composites were determined from the lyophilized storage medium (water) and the residue was re-suspended in 0.6 mL of acetonitrile, filtered in 0.22 μm PTFE filters and analyzed by HPLC.

Instrumentation and Method

The analyzes were performed on a Jasco HPLC chromatograph (Jasco International Co., Ltd., Tokyo, Japan) that was equipped with an intelligent pump PU-980, a ternary gradient unit LG-980-02, an intelligent column thermostat CO-2060 Plus, an intelligent detector UV-975, and an injection valve that was equipped with a 20 µL sample loop (Rheodyne, Thermo Fischer Scientific, Waltham, MA, USA). The system was controlled and the experimental data analyzed with the ChromPass software (version v1.7, Jasco International Co., Ltd., Tokyo, Japan). Separation was performed on a Lichrosorb RP-C18 column (25 × 0.46 cm) at a column temperature of 21 °C. The mobile phase was a mixture of acetonitrile (A, HPLC grade) and water (Milipore ultrapure water) and a gradient was applied according to the following method: 0–15 min, linear gradient 50–80% A; 15–25 min, linear gradient 80–50% A. The flow rate was 0.9 mL/min and the injected volume was always 20 μL. UV detection was performed at 204 nm to monitor the elution of all analytes (Bis-GMA and TEGDMA) because it shows significant absorption at this wavelength. Stock solutions of Bis-GMA and TEGDMA reference standards (1 mg/mL) were prepared in acetonitrile and stored at 4 °C. The linearity of the response to the analytes was established with four concentration levels and the regression factors R2 were higher than 0.998. All of the analyses were perform in triplicates for both the standard and the samples.
The residual monomer amount has been determined from the HPLC chromatograms of the extracts and it was calculated as percentage related to the initial amount of monomer in the sample and the weight of the sample, respectively [26].

2.2.3. Mechanical Properties and Statistical Analyses

The samples used for testing the mechanical properties were obtained in teflon molds and light-cured with a LED.E dental lamp (GuilinWoodpecker Medical Instruments Co., Guangxi, China) with a wave length of 470 nm and intensity of 950 mW cm. For each tested material (F00, F02, F03 and the experimental giomer) a number of 10 samples were fabricated.
Before determining mechanical properties, all samples were stored for 24 h in a thermostatic bath at 37 °C. The containers were left to dry at room temperature and after another 24 h they were measured with a digital measurer. Mechanical properties were analyzed according to ISO 4049/2000 standard [27]. For measuring mechanical resistance properties, a Universal Testing Machine (LF Plus, LLOYD, Instrument, Ametek Inc., West Sussex, England) and Nexygen software was used.

Compressive Strength

The samples for determining the compressive strength were of cylindrical shape, 8 mm high and 4 mm in diameter. The polymerization of the samples was performed in increments of 2 mm height, for 40 s each. The pressing speed of the machine was 0.75 mm /min.
For the calculation of the compressive strength (CS) in MPa, the following formula was applied (1) [27]:
C S = F / π r 2
where F is the maximum applied strength (N), and r is the sample radius (mm).

The Diametral Tensile Strength (DTS)

For determining tensil strength, the diametral compression test was used. Samples were prepared in the same way as described for the compression strength test, having a cylindrical shape, 3 mm thick and 6 mm in diameter. The samples were pressed against the cylindrical generator. The force (F) acting on the cylinder, caught between the plates of the device, determines the appearance of the tensile forces on the vertical diameter plane. The calculation formula for tensile strength (DTS, measured in MPa) was applied as follows (2) [27]:
D T S = 2 × F / π × D × T
where F is the maximum applied strength (N), and T is the thickness and D the diameter of the sample.

Flexural Strength (FS) and Flexural Modulus

For determining the flexural strength (FS), rectangular shaped samples were fabricated in a teflon mold, 25 mm in length, 2 mm height and 2 mm width. The light-curing of the samples was performed in 5 distinct areas along the sample, on both sides, for 20 s on each point. The samples were subjected to a three-point load with length (l) = 20 mm between the supports. The transverse speed of the test machine was 0.75 mm/min.
For calculating the flexural strength (FS), the following formula was applied (3) [27]:
F S = 3 F I / 2 b h 2
where F is the maximum load applied to the specimen (N), l is the span between the supports (20 mm), and b and h are the width and height, of the specimen (mm), respectively.
The Young’s modulus (YM) for bending determined the slope of the linear part of the force-deflection diagram.

Statistical Analyses

The data were analyzed with the ANOVA test and Tukey test for post-hoc comparison between sample groups; the significance level α = 0.05. The statistical analysis was performed with the Origin2019b Graphing&Analysis software (OriginLab, Northampton, MA, USA).

3. Results

3.1. Fluoride Release

Figure 1 illustrates total fluoride release distribution over a period of 60 days of investigation.
In Figure 1, total fluoride release/day is presented, with the highest mean value registered for material B-F02. During the first day of investigation, material B-F00 releases a higher cumulated fluoride quantity when compared to the experimental giomer. However, starting with the 2nd day and over the entire period, the lowest mean values of cumulative fluoride release/day were registered by B-F00.
During the first day, the highest mean values for total fluoride release are registered for B-F03 (3.099 ppm) and B-F02 (3.389 ppm). The mean values of fluoride release in the first day of investigation for the experimental giomer G was 1.871 ppm and for B-F00, 2.064 ppm.
On the 7th day, the highest value of total fluoride released is 8.11 ppm (B-F02) and the lowest is 3.10 ppm (B-F00). The total fluoride released by the experimental giomer, on the 7th day was 6.43 ppm, close to 6.50 ppm registered for B-F-03 giomer.
On the 30th day, the highest value of total fluoride released was registered for B-F02, 21.39 ppm and the lowest for B-F00 (5.55 ppm). The total fluoride released by the experimental giomer on the 30th day was 17.84 ppm, and for B-F03, 14.54 ppm.
At the end of the investigation period, at 60 days, the mean values of the total amounts of fluoride released were as follows: 32.92 ppm (B-F02), 23.06ppm (B-F03), 22.04 ppm (G) and 6.08 ppm (B-F00).

3.1.1. Statistical Analyses for Total Fluoride Release over a 60 Day Period:

Four samples were fabricated for each of the investigated materials and their behavior regarding fluoride release was observed over a 60 days period and it showed statistically significant differences (p < 0.05).
For the cumulative fluoride release, the conclusion was that there are statistically significant differences among all analyzed groups (p < 0.05) on each day. The Tukey test highlighted the differences between: B-F00 and B-F02 and B-F03 over the entire period, whereas B-F02 and B-F03 presented no statistically significant differences over the first 7 days of investigation, but they became noticeable starting with day 14. No statistically significant differences were noted between G and B-F03 over the entire 60 days period, also G-B-F00 had no statistically significant differences over the first 3 days, G and B-F02 had no statistically significant differences in the last 4 days of the investigation, with all other days the differences between G-B-F00 and G-B-F03 being statistically significant.
When analyzing the mean values of fluoride quantity released in the 2nd day, (Figure 2), they are lower than the first day, with the experimental giomer G releasing 0.908 ppm, similar to F02, 0.936 ppm. B-F03 registered mean values of 0.801 ppm, and B-F00, 0.199 ppm fluoride.
Mean values of fluoride release for G and B-F02 on the 7th day of the investigation are around 0.7 ppm; for B-F03, 0.44 ppm and for B-F00, 0.19 ppm.
The highest mean value of fluoride release, compared to the other giomers, was registered on the 14th day, for G (0.69 ppm). The average values of fluoride released by the experimental giomer during the rest of the investigation period were: 0.54 ppm (on the 21 day), 0.30 ppm (on the 30 day) and 0.14 ppm on the 60th day.
Material B-F02 released the highest fluoride mean values during days 21st, 30 and 60 (0.58 ppm, 0.55 ppm, 0.38 ppm respectively). In Figure 2 we can observe that although B-F00 released around 2 ppm fluoride during the first day, in the later days, mean values decreased (0.19 ppm on the 2nd day, 0.19 ppm day 7, 0.07 ppm day 30 and 0.01 ppm the 60th day).
Although the daily amount of fluoride released by the experimental giomer on the first day and at the end of the investigation period approaches the value of the B-F00 giomer, during 21 days of investigation it is quite constant, being closer in value to the of the giomer B-F02.

3.1.2. Statistical Analyses of Daily Fluoride Release

For the daily fluoride release there were statistically significant differences found among all analyzed groups (p < 0.05) per investigation days. Tuckey showed differences between the B-F00 and B-F03 pair, B-F00 and B-F02 pair during the entire investigation period, wearas the B-F02 and B-F03 pair displayed no statistically significant differences. The experimental giomer G presented no differences in comparison to B-F02, however, for the most of the investigation period, statistically significant differences were detected for B-F00 and B-F02 materials.

3.2. HPLC Determination of Residual Monomers

The quantity of residual monomers released by the investigated materials were determined at 30 days, after performing the sorbtion and solubility test [13].
In Table 2 and Figure 3 (chormatograms) the highest percentage of the residual monomers (Bis-GMA and TEGDMA) is shown in the depositing environment of B-F00 (3%), wearas the lowest was found for G (1.2%). The commercial giomers released a higher percentage of TEGDMA, the experimental giomer released a higher percentage of Bis-GMA, somewhat similar to B-F03.

3.3. Mechanical Properties

In Figure 4 and Figure 5, the mean values of the mechanical properties of the investigated materials are presented. The highest value for CS is that of material B-F02. The compresion strength of the experimental giomer G, is situated between the values obtained for B-F00 and B-F03. Regarding DTS resistance, B-F00 had the highest value, whilst the highest FS was for material B-F03. The experimental giomer G has a lower traction resistance and FS compared to the other investigated materials.
Regarding the elasticity module, the highest registered value among the investigated samples was obtained for B-F03, and the lowest for the experimental giomer.
The limit imposed in the international standard ISO 4049/2009 for flexural strengths of giomers is 80 MPa. All the giomers presented values of flexural strengths higher than this limit [27].

Statistical Analysis

The study groups are the 4 different biocomposites, the comparison being made between all of them, for each mechanical test, each group being represented by n = 10 results.
For the compresion strength test, samples showed a high statistically significant difference. The Tukey test for post hoc comparisson found statistically significant differences between all sample groups with the exception of the following pairs: B-F00 and B-F02; B-F03 and G.
For the traction strength test, the sample groups had a low statistical difference (p = 0.04565), the Tukey test showed a signifficant difference only between B-F00 and G pair.
For the Diametral Tensile Strength (DTS) performed in 3 distinct points the one-way ANOVA indicates a statistically significant difference (p-value = 0.00368) between B-F02-B-F03 and B-F03-G.

4. Discussion

Fluoride release from dental materials is possible by diffusion of set ions in a wet environment. To this effect it is important to take into account the materials capacity to sustain water diffusion without having an excessively high water sorption [6]. Itota et al. [7] stated that in addition to water sorption, partial removal of polymeric chains from the resin matrix of polymerized composites can also influence fluoride release capacity [9] very important because of its biocompatibility [28].
Fluoride release mostly takes place during the first week, through an acid-base reaction on the surface of the pre-reacted glass particles [9].
In the current study it was determined that the experimental giomer G released 1.87 ppm of fluoride after the first day, 0.766 ppm after a week and 0.307 ppm fluoride after 30 days. The giomer B-F03 released 3.1 ppm fluoride after the first day, 0.442 ppm after the first week and 0.242 ppm fluoride after 30 days.
Harhash et al. found that the commercial giomer Beautifil Flow Plus F03, A2 color, released 1.0020 ppm of fluoride after the first day, 0.4140 ppm after the first week and after four weeks 0.3165 ppm of fluoride. The differences between materials may be due to the size of the samples, material batches and the sensitivity of the devices used for analyses [9].
High performance liquid chromatography (HPLC) is considered to be the most performant technique for determining the type and quantity of residual monomers released by composite resins. By HPLC technique, the non-polar compounds were eluted from the matrix of the composite resin, separating the components in the order of their hydrophobic properties. Dissolution of the monomers in the mobile phase leads to a more controlled separation [29].
Residual monomers were released from the polymeric matrix through the process of diffusion, depending on their hydrophobicity, molecular weight and flexibility of the polymer. TEGDMA is lighter and has a higher mobility when compared to the more rigid Bis-GMA molecule, and as a consequence was released in a higher amount from the matrix [30]. Depending on the storage solution, hydrophilic structures will be attracted to a watery environment, whereas an organic medium will be more accessible to hydrophobic particles. The diffusion of the storage liquid into the micro-pores of the resin matrix will lead to a progressive expansion of the pores and swelling of the polymeric matrix. The degree of swelling is also influenced by the rigidity and reticulation of the polymeric matrix. It is important that the quantity of residual monomers released to be as low as possible, ensuring a complete polymerization of the material. Ferracane and Condon stated that 85–100% percent of the residual monomer is released during the first 24 h [31]. Other literature data suggests also that a higher quantity of TEGDMA is eluted during the first 24 h after setting, and a lower quantity after one month [31].
In their study, Ilie et al. reported that Beautifil Bulk restorative giomer has a flexural strength of 106.0 ± 12.7 MPa, the quantity of the inorganic filler (87 filler wt%) being reflected in the mechanical properties. ISO standard 4049 does not specify an inferior limit for the elasticity module that is in direct relation to the restoration material deformation when under the action of masticatory forces [32].
The current study found that giomer B-F00 (67.3 filler wt%) has a flexural strength of 114.83 ± 15.45 MPa, even though the filler quantity is lower than that of a bulk fill giomer [10]. Also, the study of Colceriu-Burtea et al. [26], found that Beautifil II has a flexural strength of 115.7 MPa and the experimental giomers, 89.2–108.8 MPa. The experimental giomer (60 filler wt%), that has Bis-GMA and TEGDMA in the resin matrix, registered a value of 98.822 ± 13.02 MPa for the flexural strength.
Imai and al. [5] stated that the resin matrix composition has the main influence upon the flexural strength of flowable composites and an explanation based solely on the filler percentage is insufficient. They reported a value of 116.2 MPa for the flexural strength of B-F00. The consistency of the monomer mixture, the type of filler, size and particle distribution can influence the mechanical properties of materials. Shouha found a 126.3 MPa value for the flexural strength of giomer B-F03 [33].
Regarding the compression strength, the highest value was identified for B-F02 with 255.95 ± 28.19 MPa. Other sources stated that B-F00 and B-F03 have compression strength of 358 MPa and flexural strength of 120 MPa and conventional giomers (Beautifill II) compression strength of 271,356 ± 19,653 MPa [34,35].
All the giomers investigated in this study differ from each other but not to a large extent and the results obtained are comparable to those in the literature. The limitations of the present study consist in the fact that there are a only few reports in the literature on flowable giomers and the results of the investigations may differ, depending on the method or equipment used
In the future, it would be interesting to investigate other properties of giomers, glass ionomers and dental composites; perhaps an important aspect would be how these materials could help in the process of dental remineralization [36,37].

5. Conclusions

The daily amount of fluoride released by the experimental giomer is close to the values reported for Beautifil giomers, making them similarly effective regarding the caries prevention and remineralization aspects. On the first day, in descending order of the fluoride amount released we obtained the following: B-F02 ˃ B-F03 ˃ B-F00 ˃ G and at the end of the investigation period, at 60 days: B-F02 ˃ B-F03 ˃ G ˃ B-F00. The highest mean value for total fluoride release/day is registered for material B-F02.
The Beautifil giomers released a higher percentage of TEGDMA, the experimental giomer released a higher percentage of Bis-GMA, somewhat similar to B-F03. Residual monomers are somewhat inevitable, given the constant interaction direct restoration materials have with water.
All the giomers presented values of flexural strengths higher than the limit imposed by the standard, so all tested materials, including the experimental giomer have adequate mechanical properties.
Further investigations, for example fluoride recharge through topical applications and re-release into the environment, are still needed to reach optimal qualities of the experimental giomer, making it suitable for dental applications.

Author Contributions

Conceptualization, D.P. and C.P.; validation, D.D.; investigation, S.C. and M.F.; writing—original draft preparation, M.E.R.; supervision, M.M. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

The data presented in this study are available on request from the corresponding author.

Acknowledgments

This work was sustained by: Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, by the internal Project: Nr. 1680/75, of 19 January 2018; the Romanian Ministry of Education and Research, Project nr. 334PED/2020. The authors thank Nils Becker, ISM—Industrial Specialty Materials, Ferro GmbH, Frankfurt, Germany for providing the IS 50 1102 Dentalglass 0.70 sample.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Lee, I.B.; Cho, B.H.; Son, H.H.; Um, C.M. Rheological characterization of composites using a vertical oscillation rheometer. Dent. Mater. 2006, 23, 425–432. [Google Scholar] [CrossRef]
  2. Wood, I.; Jawad, Z.; Paisley, C.; Brunton, P. Non-carious cervical tooth surface loss: A literature review. J. Dent. 2008, 36, 759–766. [Google Scholar] [CrossRef]
  3. Lazaridou, D.; Belli, R.; Petschelt, A.; Lohbauer, U. Are resin composites suitable replacements for amalgam? A study of two-body wear. Clin. Oral Investig. 2015, 19, 1485–1492. [Google Scholar] [CrossRef] [PubMed]
  4. Sumino, N.; Tsubota, K.; Takamizawa, T.; Shiratsuchi, K.; Miyazaki, M.; Latta, M.A. Comparison of the wear and flexural characteristics of flowable resin composites for posterior lesions. Act. Odontol. Scand. 2013, 71, 820–827. [Google Scholar] [CrossRef]
  5. Imai, A.; Takamizawa, T.; Sugimura, R.; Tsujimoto, A.; Ishii, R.; Kawazu, M.; Saito, T.; Miyazaki, M. Interrelation among the handling, mechanical, and wear properties of the newly developed flowable resin composites. J. Mech. Behav. Biomed. Mater. 2019, 89, 72–80. [Google Scholar] [CrossRef]
  6. Najma Hajira, N.S.W.; Meena, N. GIOMER-The Intelligent Particle (New Generation Glass Ionomer Cement). Int. J. Dent. Oral Health. 2015, 2, 1–5. [Google Scholar] [CrossRef]
  7. Itota, T.; Carrick, T.E.; Yoshiyama, M.; McCabe, J.P. Fluoride release and recharge in giomer, compomer and resin composite. Dent. Mater. 2004, 20, 789–795. [Google Scholar] [CrossRef]
  8. Okuyama, K.; Murata, Y.; Pereira, P.N.; Miguez, P.A.; Komatsu, H.; Sano, H. Fluoride release and uptake by various dental materials after fuoride application. Am. J. Dent. 2006, 19, 123–127. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  9. Harhash, A.Y.; ElSayad, I.I.; Zaghloul, A.G. A comparative in vitro study on fluoride release and water sorption of different flowable esthetic restorative materials. Eur. J. Dent. 2017, 11, 174. [Google Scholar] [CrossRef] [Green Version]
  10. Abdel-Karim, U.M.; El-Eraky, M.; Etman, W.M. Three-year clinical evaluation of two nano-hybrid giomer restorative composites. Tanta Dent. J. 2014, 11, 213–222. [Google Scholar] [CrossRef] [Green Version]
  11. Gonulol, N.; Ozer, S.; Sen Tunc, E. Water sorption, solubility, and color stability of giomer restoratives. J. Esthet. Restor. Dent. 2015, 27, 300–306. [Google Scholar] [CrossRef]
  12. Rusnac, M.E.; Gasparik, C.; Delean, A.G.; Aghiorghiesei, A.I.; Dudea, D. Optical properties and masking capacity of flowable giomers. Med. Pharm. Rep. 2021, 94, 99–105. [Google Scholar] [CrossRef]
  13. Rusnac, M.E.; Prodan, D.; Cuc, S.; Petean, I.; Prejmerean, C.; Gasparik, C.; Dudea, D.; Moldovan, M. Water Sorption and Solubility of Flowable Giomers. Material 2021, 14, 2399. [Google Scholar] [CrossRef]
  14. Prejmerean, C.; Moldovan, M.; Silaghi-Dumitrescu, L.; Prodan, D.; Furtos, G.; Trif, M.; Popescu, V.; Pascalau, V.; Petrea, C.M.; Silaghi-Dumitrescu, R. Composition versus physico-mechanical properties of some dental experimental polymers. Mater. Plast 2011, 48, 27–32. [Google Scholar] [CrossRef]
  15. Hadi, M.R. Effect of Increased Fluoride Contents on Fluoride Release from Glass Ionomer Cements. Sys. Rev. Pharm. 2020, 11, 440–443. [Google Scholar] [CrossRef]
  16. Cury, J.A.; de Oliveira, B.H.; Dos Santos, A.P.; Tenuta, L.M. Are fluoride releasing dental materials clinically effective on caries control? Dent. Mater. 2016, 32, 323–333. [Google Scholar] [CrossRef] [PubMed]
  17. Tarasingh, P.; Reddy, J.S.; Suhasini, K.; Hemachandrika, I. Comparative Evaluation of Antimicrobial Efficacy of Resin-Modified Glass Ionomers, Compomers and Giomers–An Invitro Study. JCDR 2015, 9, 85–87. [Google Scholar] [CrossRef] [PubMed]
  18. Sauro, S.; Makeeva, I.; Faus-Matoses, V.; Foschi, F.; Giovarruscio, M.; Maciel Pires, P.; Martins Moura, M.E.; Almeida Neves, A.; Faus-Llácer, V. Effects of ions-releasing restorative materials on the dentine bonding longevity of modern universal adhesives after load-cycle and prolonged artificial saliva aging. Materials 2019, 12, 722. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  19. Abdallah, A.M.; Elshehawy, T.M.; Ibrahim, H.M. Fluoride Release and Recharge Behavior of Bioactive Glass Ionomer Cements using Ion Chromatography. Egypt Dent. J. 2019, 65, 399–406. [Google Scholar] [CrossRef] [Green Version]
  20. Choudhary, H.V.; Priyadarshni, P.; Suryavanshi, R.; Rathore, M.; Singh, N. Comparison of Two Resins with Fluoride Release and Uptake Property of Giomer and Polyacid Modified Composite-An In Vitro Assessment. JAMDSR 2019, 7, 188–192. [Google Scholar] [CrossRef]
  21. Tay, F.R.; Pashley, E.L.; Huang, C.; Sano, H.; Hashimoto, M. The glass-ionomer phase in resin-based restorative materials. J. Dent. Res. 2001, 80, 1808–1812. [Google Scholar] [CrossRef]
  22. Xu, H.H.; Eichmiller, F.C.; Antonucci, J.M.; Yves, L.K. Dental resin composites containing ceramic whiskers and pre-cured glass ionomer particles. Dent. Mater. 2000, 16, 356–363. [Google Scholar] [CrossRef]
  23. Elshweekh, R.A.; Bakry, N.S.; Talaat, D.M.; Ahmed, D.M. Fluoride release and rerelease after recharging of two hybrid resin restorations in primary teeth, “a comparative in vitro study”. Alex. Dent. J. 2019, 44, 114–119. [Google Scholar] [CrossRef] [Green Version]
  24. Bănuț Oneț, D.; Barbu Tudoran, L.; Delean, A.; Șurlin, P.; Ciurea, A.; Roman, A.; Bolboacă, S.; Gasparik, C.; Muntean, A.; Soancă, A. Adhesion of Flowable Resin Composites in Simulated Wedge-Shaped Cervical Lesions: An In Vitro Pilot Study. Appl. Sci. 2021, 11, 3173. [Google Scholar] [CrossRef]
  25. Prejmerean, C.; Prodan, D.; Vlassa, M.; Streza, M.; Buruiana, T.; Colceriu, L.; Prejmerean, V.; Cuc, S.; Moldovan, M. ATR technique, an appropriate method for determining the degree of conversion in dental giomers. Meas. Sci. Technol. 2016, 27, 124008. [Google Scholar] [CrossRef]
  26. Colceriu Burtea, L.; Prejmerean, C.; Prodan, D.; Baldea, I.; Vlassa, M.; Filip, M.; Moldovan, M.; Antoniac, A.; Prejmerean, V.; Ambrosie, I. New pre-reacted glass containing dental composites (giomers) with improved fluoride release and biocompatibility. Materials 2019, 23, 4021. [Google Scholar] [CrossRef] [Green Version]
  27. ISO-4049. Dentistry—Polymer-Based Restorative Materials; International Organization for Standardization: London, UK, 2019; Available online: https://www.iso.org/standard/42898.html (accessed on 18 April 2021).
  28. Iviglia, G.; Kargozar, S.; Baino, F. Biomaterials, Current Strategies, and Novel Nano-Technological Approaches for Periodontal Regeneration. J. Func. Biomater. 2019, 10, 3. [Google Scholar] [CrossRef] [Green Version]
  29. Cebe, M.A.; Cebe, F.; Cengiz, M.F.; Cetin, A.R.; Arpag, O.F.; Ozturk, B. Elution of monomer from different bulk-fill dental composite resins. Dent. Mater. 2015, 31, 141–149. [Google Scholar] [CrossRef]
  30. Ferracane, J.L. Resin composite—State of the art. Dent. Mater. 2011, 27, 29–38. [Google Scholar] [CrossRef]
  31. Gul, P.; Alp, H.H.; Özcan, M. Monomer release from bulk-fill composite resins in different curing protocols. J. Oral Sci. 2020, 62, 288–292. [Google Scholar] [CrossRef]
  32. Ilie, N. High viscosity bulk-fill giomer and ormocer-based resin composites: An in-vitro comparison of their mechanical behaviour. Stoma Edu J. 2016, 3, 54–62. [Google Scholar] [CrossRef]
  33. Shouha, P.; Swain, M.; Ellakwa, A. The effect of fiber aspect ratio and volume loading on the flexural properties of flowable dental composite. Dent. Mater. 2014, 30, 1234–1244. [Google Scholar] [CrossRef] [PubMed]
  34. Giomer Technology. Taking Dentistry to the Next Level. Bioactive Dental Materials. Available online: https://www.shofu.com/wp-content/uploads/Giomer-BRO-US.pdf (accessed on 18 April 2021).
  35. Quader, S.A.; Alam, M.S.; Bashar, A.K.; Gafur, A.; Al Mansur, M.A. Compressive strength, fluoride release and recharge of giomer. Update Dent. Coll. J. 2012, 2, 28–37. [Google Scholar] [CrossRef] [Green Version]
  36. Muşat, V.; Anghel, E.M.; Zaharia, A.; Atkinson, I.; Mocioiu, O.C.; Buşilă, M.; Alexandru, P. A Chitosan–Agarose Polysaccharide-Based Hydrogel for Biomimetic Remineralization of Dental Enamel. Biomolecules 2021, 11, 1137. [Google Scholar] [CrossRef] [PubMed]
  37. Butera, A.; Pascadopoli, M.; Gallo, S.; Lelli, M.; Tarterini, F.; Giglia, F.; Scribante, A. SEM/EDS Evaluation of the Mineral Deposition on a Polymeric Composite Resin of a Toothpaste Containing Biomimetic Zn-Carbonate Hydroxyapatite (microRepair®) in Oral Environment: A Randomized Clinical Trial. Polymers 2021, 13, 2740. [Google Scholar] [CrossRef] [PubMed]
Figure 1. Total fluoride release over the 60 days investigation period.
Figure 1. Total fluoride release over the 60 days investigation period.
Applsci 11 08921 g001
Figure 2. Daily fluoride release for the investigated materials.
Figure 2. Daily fluoride release for the investigated materials.
Applsci 11 08921 g002
Figure 3. HPLC chromatograms of standards and investigated samples.
Figure 3. HPLC chromatograms of standards and investigated samples.
Applsci 11 08921 g003
Figure 4. (a) The strain–stress curve of compression test; (b) traction strength test.
Figure 4. (a) The strain–stress curve of compression test; (b) traction strength test.
Applsci 11 08921 g004
Figure 5. Flexural test.
Figure 5. Flexural test.
Applsci 11 08921 g005
Table 1. Commercial Giomer and experimental flowable giomer composition.
Table 1. Commercial Giomer and experimental flowable giomer composition.
NameCodeCompositionConsistency
Beautifil flow Plus X F00B-F0010–20% Bis-GMA, TEGDMA, Bis-MPEPP, 50–60% S-PRG filler based on fluoroboroaluminosilicate glass, polymerization initiator, pigments and othersMinimal flow
Beautifil flow F02B-F0220–30% Bis-GMA, TEGDMA, 40–50% S-PRG filler based on fluoroboroaluminosilicate glass, polymerization initiator, pigments and othersLow flow
Beautifil flow Plus X F03B-F0310–20% Bis-GMA, TEGDMA, Bis-MPEPP, 50–60% S-PRG filler based on fluoroboroaluminosilicate glass, polymerization initiator, pigments and othersLow flow
Experimental giomer *G40 w% Bis-GMA, TEGDMA (3:1), 60 w% filler (SPRG, Exp-Glass, Dentalglass, FHAP)Low flow
* Bis-GMA, SPRG, Exp-Glass and FHAP were obtained at the Babeș-Bolyai University, Raluca Ripan Institute for Research in Chemistry, (Cluj-Napoca, Romania). TEGDMA, CQ, DMAEM was purchased from Aldrich. Dentalglass (0.7 μm) was provided by Ferro GmbH, Frankfurt am Main-Germany.
Table 2. The residual monomer (% ± SD) related to the weight of the sample.
Table 2. The residual monomer (% ± SD) related to the weight of the sample.
SampleTEGDMA %Bis-GMA %Total %
B-F002.5 ± 0.830.5 ± 0.093 ± 0.46
B-F021.7 ± 0.760.6 ± 0.102.3 ± 0.43
B-F031.1 ± 0.230.9 ± 0.212 ± 0.22
G0.4 ± 0.110.8 ± 0.161.2 ± 0.13
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Rusnac, M.E.; Prodan, D.; Moldovan, M.; Cuc, S.; Filip, M.; Prejmerean, C.; Dudea, D. Research on the Mechanical Properties, Fluoride and Monomer Release of a New Experimental Flowable Giomer in Comparison to Three Commercial Flowable Giomers. Appl. Sci. 2021, 11, 8921. https://0-doi-org.brum.beds.ac.uk/10.3390/app11198921

AMA Style

Rusnac ME, Prodan D, Moldovan M, Cuc S, Filip M, Prejmerean C, Dudea D. Research on the Mechanical Properties, Fluoride and Monomer Release of a New Experimental Flowable Giomer in Comparison to Three Commercial Flowable Giomers. Applied Sciences. 2021; 11(19):8921. https://0-doi-org.brum.beds.ac.uk/10.3390/app11198921

Chicago/Turabian Style

Rusnac, Mara Elena, Doina Prodan, Marioara Moldovan, Stanca Cuc, Miuţa Filip, Cristina Prejmerean, and Diana Dudea. 2021. "Research on the Mechanical Properties, Fluoride and Monomer Release of a New Experimental Flowable Giomer in Comparison to Three Commercial Flowable Giomers" Applied Sciences 11, no. 19: 8921. https://0-doi-org.brum.beds.ac.uk/10.3390/app11198921

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop