Progress in Fast and Red Plastic Scintillators

Université Paris-Saclay, CEA, List, F-91120 Palaiseau, France
Submission received: 21 January 2022 / Revised: 14 February 2022 / Accepted: 16 February 2022 / Published: 17 February 2022
(This article belongs to the Section Analytical Methods, Instrumentation and Miniaturization)

Abstract

:
Radiological detection where Cherenkov residual background can be prominent requires scintillators with increased emission wavelength. Cherenkov residual background precludes the use of UV-emitting sensors such as plastic scintillators. However, the literature is scarce in red-emitting plastic scintillators and only one commercial scintillator is currently available (BC-430, from Saint-Gobain Crystals and Detectors). In addition, X-ray imaging or time-of-flight positron emission tomography (ToF-PET) applications are also demanding on this type (color) of scintillators, but such applications also require that the material displays a fast response, which is not particularly the case for BC-430. We present herein our latest developments in the preparation and characterization of fast and red plastic scintillators for this application. Here, ‘fast’ means nanosecond range decay time and ‘red’ is an emission wavelength shifted towards more than 550 nm. At first, the strategy to the preparation of such material is explained by decomposing the scintillator to fundamental elements. Each stage is then optimized in terms of decay time response, then the elemental bricks are arranged to give plastic scintillator formulations that are compatible with the abovementioned characteristics. The results are compared with the red-emissive BC-430 commercial plastic, and the ultra-fast, violet-emitting BC-422Q 1% plastic. In particular, the first-time use of trans-4-dimethylamino-4′-nitrostilbene in the scintillation field as a red wavelength shifter allowed preparing plastic scintillators with the following properties: λ em max 554 nm, photoluminescence decay time 4.2 ns, and light output ≈ 6100 ph/MeV. This means a scintillator almost as bright as BC-430 but at least three times faster. This new sensor might provide useful properties for nuclear instrumentation.

1. Introduction

Various nuclear experiments are seeking to new detectors. The quest for new particles or improved detection efficiency is a trade-off with more constraints, thus pushing to rubbish standard, yet efficient detectors, to be replaced by new, application-driven detectors. This is the place where material chemists step in, at least in the world of nuclear instrumentation. Among the possible emission-wavelength variations of scintillators, red emitters are probably the ones with less demand [1]. Everybody knows and uses scintillators with standard emission wavelength, that is to say emitting close to 425 nm. Green-emitting plastic scintillators are useful when coupling to silicon photodiodes has to be achieved or when radiation-hard materials are necessary [2]. This being said, red-emitting scintillators are not commonly studied in this field, despite the fact they find relevant applications in physics domains, such as in the study of transient nuclear phenomena [3]. Other examples of the use of red and fast plastic scintillators may include: plastic scintillator dosimetry [4], ToF-PET [5] (when the scintillator also contains high-Z elements), real time X-ray imaging [6], and high-energy physics such as the Laser Mégajoule [7]. This last industrial application constitutes the birth of this work since red and fast plastic scintillators are the candidate of choice for the detection of low-energy X-rays.
The Cherenkov radiation spectrum is continuous and its intensity is inversely related to the square of the emission wavelength. So as to reduce or even avoid it in the counting of the incident dose rate (for example in dosimetry), it is thus necessary to work with wavelengths usually more than 550 nm. Table 1 summarizes some interesting scintillators and their main properties [8]. YAG:Ce is the only inorganic scintillator given for comparison. Its main drawback is the long decay time that precludes its use when fast counting or timing resolution are needed. BC-430 plastic scintillator is red-emitting and has a good light yield but its decay time might still be too long for some applications. To the best of our knowledge, the first red-emitting scintillator showing a fast decay time ever reported in the literature was prepared by Berlman and Ogdan [9]. This material was composed of a photonic cascade starting with 2-([1-biphenyl]-4-yl)-5-(p-tert-butylphenyl)-1,3,4-oxadiazole (butyl-PBD), 1,4-bis(5-(o-tolyl)oxazol-2-yl)benzene (dimethylPOPOP), perylene, and rubrene, all these fluorophores being hosted in polystyrene. Their trick was to irradiate the scintillator with electrons created from a LINAC, thereby reducing the 35 ns preliminary decay time down to 5 ns only by molecular degradation. However, the scintillator revealed to recover from irradiation (as they use to be [10]) and the decay time reincreased accordingly. Since this seminal paper, several strategies have been tested towards the preparation of new red-emitting plastics (Table 1), with the use of organic fluorophores showing high-range aromaticity or internal Förster energy transfer, organometallics, BODIPY or xanthene derivatives, or more recently with organic molecules showing thermally activated delayed fluorescence (TADF). Noteworthy, our laboratory published some years ago their preliminary results on such chemical modifications for new red and fast plastics [11]. Thus, a polystyrene-based scintillator including 2,5-diphenyloxazole, Nile Red, and piperidine as the quencher displayed low scintillation yield and moderate decay time but at high wavelength (more than 600 nm).
This publication presents our latest results on this field. It is decomposed as follows. The choice of the primary and the secondary fluorophores was performed independently, then ternary mixtures (matrix + primary fluorophore + secondary fluorophore) were studied, eventually with the addition of a photoluminescent quencher. All these sequences are presented and discussed individually. In particular, the introduction of a new red-emitting fluorophore in the scintillation field provides new insights and acceptable characteristics for a red and fast plastic scintillator. Thus, a plastic scintillator consisting in polystyrene, p-terphenyl and trans-4-dimethylamino-4′-nitrostilbene displayed adequate photophysical characteristics and a decent light output, close to BC-430.

2. Materials and Methods

2.1. Materials

All chemicals were purchased from Sigma-Aldrich, except for PMP and p-sexiphenyl that were obtained from TCI Europe Research Chemicals. Styrene and vinyltoluene were distilled prior to use. 4-Bromo-p-terphenyl was prepared according to a published procedure [20]; a white powder was obtained with an 80% yield after purification. N-(2-ethylhexyl carbazole) was prepared according to our previous work [21]. Spectroscopic toluene was obtained from Carlo Erba. BC-430 and BC-422Q 1% and 2% plastic scintillators were obtained from Saint-Gobain Crystals and Detectors; unfortunately, their purchase date is not known and one has to keep in mind that BC-422Q may suffer from aging with time [22]. All monomers and amines were vacuum-distilled before use, monomers being also dried over calcium hydride. Liquid scintillators were prepared by dissolving the dyes into spectroscopic toluene and were neither degassed nor saturated with neutral gas. The reason is twofold: the presence of oxygen decreases the decay time, and the saturation with neutral gas is modified by oxygen diffusion within the liquid. Plastic scintillators were prepared according to our internal procedure, except the fact that the monomers were not degassed prior to polymerization. After heating the monomer with the suitable molecules until complete polymerization, the raw material was cut and polished until obtaining a plastic scintillator with dimensions 49 mm diameter and 30 mm thickness (unless otherwise stated), which are equivalent to the size of BC-422Q 1% (Φ 50 mm, h 10 mm) or BC-430 (Φ 50 mm, h 50 mm) used as reference materials.

2.2. Methods

Fluorescence spectra were recorded with a Fluoromax 4P spectrofluorometer (Horiba Jobin Yvon, Palaiseau, France) monitored with FluorEssence software. Fluorescence spectra were recorded orthogonally to the excitation light. A time correlated single photon counting (TCSPC) module was used to record the lifetime of the samples. Two different excitation wavelengths were used, 274 nm and 368 nm, with pulse widths <1.2 ns. In liquid state, TCSPC analyses were performed in standard 1 × 1 × 3 cm3 quartz cuvettes with the emission recorded at 90° from the excitation diode. Plastic scintillators were excited on their cylindrical edge, approximately at a depth of 0.5 cm away from the flat face, the latter being directed toward the photodetector of the spectrofluorometer. Decay spectra were fitted using the DAS6 software (Horiba Jobin Yvon). In each case, a biexponential fit was adjusted so that the χ2 was in the range 1.00–1.20. The instrument response function was recorded by replacing the sample with a 3 cm3 quartz cuvette filled with Ludox®. The mean decay times are given with two decimals, for a better comparison between the materials. Radioluminescence spectra were acquired according to our latest published experimental procedure [2] with a beta-emitting 90Sr/90Y source (31.9 MBq as of November 2020).
The absorption characteristics of molecules were recorded with an Cary 60 UV–vis spectrophotometer (Agilent, Les Ulis, France), with an optical path of 1 cm.
Pulse-height spectra were obtained as follows. In a black box, the scintillator was coupled with optical grease to a blue-sensitive R6231 photomultiplier tube (Hamamatsu, Massy, France) or a red-sensitive 9202SB photomultiplier tube (ET Enterprises, Uxbridge, UK), depending on the scintillator to be tested, operating at +1100 V or −1700 V, respectively. The anode fed a DT5730SB digitizer from CAEN. A 137Cs source (gamma ray, 500 kBq as of November 2020) located ca. 10 cm away from the scintillator or a 36Cl source (beta emitter, 6 kBq as of November 2020) placed on the top of the scintillator were used, and the obtained pulse height spectrum was recorded during 500 s.

3. Results and Discussion

Fast and red plastic scintillators can be decomposed into the following components: polymer, fluorophores, and—if necessary—photoluminescence quencher. Each elemental brick was individually examined to allow a better understanding on possible limitations or improvements. Polystyrene or poly(vinyltoluene) were considered as the polymer building block since they are very well-known polymers and are the ones used in the composition of almost all commercial plastic scintillators [1]. No other polymers were considered in this study. In addition, thermally-assisted radical polymerization was used to polymerize the suitable, highly purified monomers.
To get more rationale on the results and insight into each chemical’s role, binary mixtures, that is to say matrix + primary fluorophore or matrix + secondary fluorophore were studied first. Each fluorophore indeed has its solvent-dependent photophysical properties (emission wavelength and more particularly herein decay time) and has to be experimentally assessed. The ‘Holy Grail’ would be a fluorophore combination presenting the desired time characteristics, in other words without necessity to quench their photoluminescence with extra molecules. This would afford a highly scintillating, time-stable, yet fast plastic scintillator.
It is noteworthy that the shape, thickness, and coating of a scintillator have a large influence on its resulting decay time [23]. A 50% increase of the decay time can be observed when increasing the material’s thickness from 0.2 to 5 cm [24]. The scintillator needs to be wrapped with black material to mitigate internal reflections. Intuitively, thinner scintillators afford the best timing properties. The purpose of our work was to find out the best chemical composition; no morphology improvement was therefore performed. This is why each table referencing timing properties of plastics mentions the diameter and the thickness of the studied materials.

3.1. Intrinsic Limitations of the Spectrofluorometer Setup

Our equipment uses two different Horiba Jobin Yvon NanoLED excitation sources that operates at either 274 nm or 368 nm (N-270 and N-370 LED heads, respectively) for time-correlated single photon counting experiments. This constitutes the main limitation of this study since these two diodes display typical pulse widths less than 1.2 ns, so close to the best decay times we are currently measuring and expecting (and even longer than commercial references BC-422Q 1% and 2%) [25]. One can see that the excitation profile is not purely monoexponential, with a bump appearing a few nanoseconds after the pulse. Their full-width at half maximum (FWHM) values are 1.48 ns ± 0.11 ns and 1.68 ns ± 0.11 ns. Without any access to better-resolved pulse diodes, the results are presented as such.

3.2. Matrix + Primary Fluorophore Mixtures

Such combinations have been widely documented and reviewed [24] by many pioneering works on plastic scintillator formulations. These so-called binary mixtures have proven to be the fastest decaying scintillators: adding a wavelength-shifter to the solution implies supplementary energy transfers that can occur both radiatively and non-radiatively. So as to perform a fast screening, various molecules suitable for scintillation purposes were solubilized in toluene at 1 wt %, and their photoluminescence decay time was recorded by time-correlated single photon counting (TCSPC) measurements.
Among other strategies [26], the intramolecular heavy atom quenching was assessed by adding one or two bromine atoms on the para positions of p-terphenyl. It seems that the fastest UV-emitting plastic scintillator ever described was prepared according to this approach [27]. Thus, 4-bromo-p-terphenyl was synthesized according to a published procedure [20]. According to Scheme 1, bromine reacted on p-terphenyl in a mixture of dichloromethane and trifluoroacetic acid and readily afforded 4-bromo-p-terphenyl with an 80% yield. Except N-(2-ethylhexylcarbazole) which was also prepared, all other tested molecules were used with commercial grade and no further purification. For all scintillators described thereafter, it is noteworthy that the solutions were not degassed so as to allow dissolved oxygen to act as a potential quencher of long-lived stated. The results of 19 different benchmarked molecules are given in Table 2. A non-linear fitting was chosen between single or biexponential decay so that the χ2 fitting value was restricted to the range 1.00–1.20. Some of these molecules are known to display either a concentration-dependent (2,5-diphenyloxazole, N-(2-ethylhexyl)carbazole, pyrene), or an oxygen-sensitive (naphthalene, pyrene) decay time. Therefore, these results have to be considered as a fast qualitative survey of family of molecules that could be suitable to the foreseen application. The results show that phenylene- and PBD-derivatives are of particular interest in this context. In the oligophenylene series, the photoluminescence decay time shortens when increasing the number of phenyl groups, however at the expense of the solubility of the molecule.
A possible photoluminescence quenching of p-terphenyl and p-quaterphenyl with benzophenone or hindered amines was also tested with piperidine or N,N-diisopropylethylamine (also known as Hünig’s base). At least in the toluene medium (Table 3), all three quenchers proved their efficiency with the best results observed for p-terphenyl quenched with piperidine. Thus, starting with already fast materials (<τ> = 1.45 and 1.11 ns for p-terphenyl and p-quaterphenyl, respectively), quenching leads to decay values close to 1 ns, placing them in the range of the instrument response function provided by the NanoLED characteristics (Figure 1). At this stage, no care was taken on the photoluminescence or even scintillation efficiency.
We then turned our attention on binary plastic compositions of p-terphenyl, p-quaterphenyl, and 4-bromo-p-terphenyl, these fluorophores being eventually quenched with benzophenone. Table 4 resumes the photoluminescence properties of various plastic scintillators compared with BC-422Q 1% and 2% commercial plastic scintillators. According to the literature, these scintillators are assumed to be quenched with benzophenone. All scintillators are still UV-emitters, with BC-422Q 2% and PS p-T 2 B 2 (see Table 4 for the interpretation of this abbreviation) which are the two scintillators emitting at wavelengths more than 400 nm. This effect might be related to the use of 2% of benzophenone that absorbs part of the emitted light below 400 nm.
Among the scintillators listed in Table 4, the fastest formulations were compared in terms of radioluminescence spectra. Thus, each scintillator was exposed to a beta emitting 90Sr/90Y radioactive source, and their photoluminescence integral was compared with the same commercial plastics BC-422Q 1% and 2%. Table 5 gives the radioluminescence emission maximum (whose spectra are also given Figure 2), the normalized emission integral against BC-422Q 1% and the corresponding relative light yield, and another parameter we have recently introduced. This is the light intensity given by the combination of the pulse shape with the pulse amplitude, expressed in ph/MeV/ns [2]. The relative light yield was taken by pulse height spectrum using a 137Cs gamma ray source using a standard pulse height spectrum setup.
For all compounds, a strong dependence of the decay time with the primary fluorophore’s concentration is observed. Whereas PPO-based plastics have faster decays for low concentrations [11], herein p-quaterphenyl plastics are accelerated when increasing the concentration. The case of 4-bromo-p-terphenyl is more subtle. The decay lies between 2.95 ns and 3.31 ns between 0.5 and 1.5 wt %. At 3.5 wt %, the decay time and the light yield as well show a dramatic improvement, until reaching the performances of BC-422Q 1%, but with no quencher inside. It is noteworthy that at so high concentration 4-Br-p-T did not dissolve entirely as small aggregates were still visible. Even if not homogenous, this plastic scintillator could therefore become a suitable alternative to BC-422Q 1% for use with a long-term stability requirement because it does not embed any volatile quencher.

3.3. Matrix + Secondary Fluorophore Mixtures

Intrinsically red-emitting fluorophores present slower decay times than UV-emitting fluorophores as a linear dependence of lifetime with the emission wavelength is predicted [8]. The same procedure as for primary fluorophores has been repeated, that is to say dissolving at low concentrations known red emitting fluorophores that are soluble in toluene, and to check their photoluminescence decay time thanks to TCSPC. The results are given in Table 6. Preliminary studies have shown that polar fluorophores could be added at a rather high concentration to give fast decaying liquid scintillators [28]. We decided to withdraw this strategy since the as-prepared scintillators with such high concentrations must present very strong self-absorption. Nile red was our primary candidate [11], despite its long decay time (27.3 ns). Rubrene was first used by Berlman et al. [9], the two perylenedicarboximide and the two pyrromethene derivatives that have been tested revealed to be too long-decaying, and the best observations were obtained with 4-(dicyanomethylene)-2-methyl-6-(4-dimethylaminostyryl)-4H-pyran (DCM) and 4-dimethylamino-4′-nitrostilbene (DANS). Molecules from the xanthene family (Eosin Y, Erythrosin B, Rhodamine derivatives) were also tested but displayed poor solubility in polar media such as toluene, polystyrene, or poly(vinyltoluene), even at the very low content we are looking at—typically 0.03 wt %. A second strategy was thus developed but not presented herein. Copolymers made from styrene and highly polar monomers were prepared along with the xanthene derivative. However, after several weeks, the materials usually degraded, deformed, and became cloudy. This degradation was, however, not mentioned in preceding literature [3,14].
DCM is a molecule that exhibits considerable variability of its photoluminescence response regarding the polarity of the solvent it is dissolved in. DCM was already mentioned as a potential shifter for polystyrene-based scintillators [29]. Photoluminescent literature precedents [30] as well as laboratory measurements are resumed in Table 7. It turns out that, in apolar solvent, DCM is extremely fast-decaying, with an interesting emission wavelength for our given application ( λ em max   550   nm ), albeit at the expense of the quantum yield, with toluene being the best example of such behavior. Accordingly, DCM in styrene was also tested. The observed 0.95 ns decay time must be limited by the timing resolution due to the pulse width excitation of our spectrofluorometer, so the decay time of DCM in styrene must be taken with caution. Experimental measurements in PMMA are in good agreement with literature precedents (lines 2 and 1, respectively). Unfortunately, plastic rigidity increases the photoluminescence decay time of DCM—whatever its concentration—towards a 3.8 ns value.
The second molecule that is potentially interesting is trans-4-dimethylamino-4′-nitrostilbene (usually abbreviated as DANS), known as a push-pull chromophore [31]. To the best of our knowledge DANS has never been used in the scintillation field. The absorption maximum of a 0.002 wt % of DANS in toluene (i.e., 7.45 × 10−5 mol·L−1) is located at 437 nm, with a calculated absorption molar coefficient of 22,600 L·mol−1·cm−1 (literature 447 nm and 26,630 L·mol−1·cm−1 in chlorobenzene [32]). This last value is adequate for a secondary fluorophore role as it falls between 9,10-diphenylanthracene (ε 14,000 L·mol−1·cm−1, cyclohexane [33]) and POPOP (ε 47,000 L·mol−1·cm−1, cyclohexane [33]) which are two wavelength shifters particularly used in scintillation. DANS displays a maximum of emission equal to 560 nm and a photoluminescence decay time of 3.28 ns at 0.002 wt % in toluene. This decay time value looks long compared with the 0.94 ns value for its lifetime reported in the literature [32]. This fast decay induces a low photoluminescence quantum yield (0.10 in chlorobenzene [32]), which may be reduced by a twisted intramolecular charge transfer. We also noticed that in toluene, this molecule is also sensitive to traditional quenchers, as can be seen in Table 8. Figure 3 gives the photoluminescence decay profiles of seven liquid scintillators being quenched with either benzophenone, piperidine, or the Hünig’s base at concentrations of 1.6 wt % or 4.8 wt %. It was unexpected to see an afterglow appear for ‘quenched’ scintillators with benzophenone. In that case, not only is the prompt photoluminescence affected, but a delayed photoluminescence appears. This behavior is still unclear to our eyes. On the other hand, both piperidine and Hünig’s base were efficient quenchers, with a quenching efficiency dependent with the quencher concentration, at least for the two studied concentrations. Figure 4 shows a time-resoled emission spectroscopy spectrum of DANS in toluene and quenched by Hünig’s base. As such, the emission characteristics are perfect for our aimed application. Thus, DCM and DANS were selected as potent wavelength-shifters for the design of red and fast plastic scintillators.

3.4. Full Red-and-Fast Plastic Systems

To resume, p-terphenyl or its 4-brominated derivative have been chosen as primary fluorophores, when DCM and trans-4-dimethylamino-4′-nitrostilbene can be useful as secondary fluorophores. Plastic scintillators were thus prepared, starting from polystyrene as the matrix. In addition, several other secondary fluorophores that were presented in Table 6 were also benchmarked. All secondary fluorophores were tested at three different weight concentrations, from 0.01 wt % up to 0.05 wt %. The results are summarized in Table 9.
The first observation is the fact the DANS-based scintillators are not as fast as their liquid equivalents, with TCSPC values giving around 4 ns. This was already observed for Nile red-based scintillators [11]. The radioluminescence spectra show emission wavelengths that are in agreement with the photoluminescence spectra.
The determination of the light output of the scintillators was performed either with a radioluminescence setup (90Sr/90Y excitation) or with a more traditional pulse-height spectrum methodology (36Cl excitation). In both cases, beta emitters were used, and the plastic scintillators were benchmarked against BC-430 commercial plastic. This light output is then divided by the mean decay value, which gives the number of photons per deposited energy per time. This parameter is thus the best parameter for most applications, and it favors very fast materials. Here, BC-430 and BC-422Q 1% afford 552 and 1118 ph/MeV/ns, respectively. The best results for our prepared scintillators were obtained with the DANS-based scintillators, with a value of the same order of magnitude as for BC-422Q 1%. The weakest materials were the DCM-based since the quantum yield of DCM in polystyrene is too low.
Having in hand promising materials with the use of DANS, it is noteworthy that this molecule can be quenched by amines or benzophenone as shown before. Thus, the same PS + p-terphenyl + DANS (0.01 wt %) were prepared with three different amounts of benzophenone, piperidine, or Hünig’s base. Unfortunately, the time stability was not in favor to the scintillators loaded with the two amines. After almost 18 months of preparation, the materials suffered from intense visual degradation (Figure 5). The DANS molecule probably reacted with the amines since the emission spectra are totally different from the pristine materials. This visual information was confirmed by fluorescence spectroscopy, where all scintillators had almost the same fluorescence spectrum immediately after production, and Figure 6 shows their photophysical degradation. The blue shift of the emission spectrum is confirmed for the scintillators containing the amines only, with emission maxima located close to 470 nm for the two highest quenched scintillators (P4.8 and H4.8), when the neat or even the benzophenone-quenched scintillators keep their emission maxima close to 560 nm.

4. Conclusions

Red and fast plastic scintillators have been decomposed into individual elements to better optimize their formulation. As a violet-emitting plastic scintillator, highly concentrated 4-bromo-p-terphenyl in polystyrene displays equal performances to BC-422Q 1%, but without the use of any quencher. This would allow a more stable material compared to previous studies about the time stability of quenched scintillators [22]. More than 4-bromo-p-terphenyl, several other molecules may act as nanosecond-range, UV-emitting fluorophore in a polymer matrix: oligophenylene family and several oxadiazoles among other.
It was awaited that adding a wavelength-shifter increases the decay time. However, two different orange-emitting molecules could fit our purpose: DCM and trans-4-dimethylamino-4′-nitrostilbene. DCM leads to very fast scintillators but with poor scintillating properties. Trans-4-dimethylamino-4′-nitrostilbene whose first use in the scintillation field (at least to the best of our knowledge) is described herein allocates both fastness and high light yield. For both fluorophores, mean decay time and FWHM in the range of 4 ns are obtained, which grant them the fastest scintillators with emission wavelength more than 550 nm ever described. Interestingly, p-terphenyl and DANS that are our final choice are both sensitive to quenching with amines. Comparing with commercial BC-430, a PS + p-T + DAANS configuration leads to a plastic scintillator with almost same light output but three times faster. Unfortunately, these scintillators were not stable with time when being quenched with piperidine or N,N-diisopropylethylamine. This work falls within recent efforts to find fast and red scintillators, whether organic or inorganic [35].

Funding

This project received funding from the Cross-Disciplinary Program on Instrumentation and Detection of CEA, the French Alternative Energies and Atomic Energy Commission. There was no external funding.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Acknowledgments

The author acknowledges the financial support of the Cross-Disciplinary Program on Instrumentation and Detection of CEA, the French Alternative Energies and Atomic Energy Commission.

Conflicts of Interest

The author declares that he has no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

References

  1. Dujardin, C.; Hamel, M. Introduction—Overview on plastics and inorganic scintillators. In Plastic Scintillators: Chemistry and Applications; Hamel, M., Ed.; Springer Nature: Cham, Switzerland, 2021; pp. 3–33. [Google Scholar] [CrossRef]
  2. Hamel, M.; Pjatkan, R.; Burešová, H. From the R&D to the commercialization of a new green-emitting plastic scintillator. Nucl. Instrum. Methods A 2020, 955, 163294. [Google Scholar] [CrossRef]
  3. Franks, L.A.; Lutz, S.; Lyons, P.B. Development of Long-Wavelength-Emitting Scintillators with Improved Decay Time Characteristics. IEEE Trans. Nucl. Sci. 1978, NS-25, 1024–1026. [Google Scholar] [CrossRef]
  4. Beddar, S.; Tendler, I.; Therriault-Proulx, F.; Archambault, L.; Beaulieu, L. Recent Advances and Clinical Applications of Plastic Scintillators in the Field of Radiation Therapy. In Plastic Scintillators: Chemistry and Applications; Hamel, M., Ed.; Springer Nature: Cham, Switzerland, 2021; pp. 425–460. [Google Scholar] [CrossRef]
  5. Gandini, M.; Villa, I.; Beretta, M.; Gotti, C.; Imran, M.; Carulli, F.; Fantuzzi, E.; Sassi, M.; Zaffalon, M.; Brofferio, C.; et al. Efficient, fast and reabsorption-free perovskite nanocrystal-based sensitized plastic scintillators. Nat. Nanotechnol. 2020, 15, 462–468. [Google Scholar] [CrossRef]
  6. Ma, W.; Su, Y.; Zhang, Q.; Deng, C.; Pasquali, L.; Zhu, W.; Tian, Y.; Ran, P.; Chen, Z.; Yang, G.; et al. Thermally activated delayed fluorescence (TADF) organic molecules for efficient X-ray scintillation and imaging. Nat. Mater. 2021, 21, 210–216. [Google Scholar] [CrossRef] [PubMed]
  7. Hamel, M.; Turk, G.; Rousseau, A.; Darbon, S.; Reverdin, C.; Normand, S. Preparation and characterization of highly lead-loaded red plastic scintillators under low energy X-rays. Nucl. Instrum. Methods A 2011, 660, 57–63. [Google Scholar] [CrossRef]
  8. Cahill, P.A. Toward red-emitting, radiation tolerant chromophores. Radiat. Phys. Chem. 1993, 41, 351–363. [Google Scholar] [CrossRef]
  9. Berlman, I.B.; Ogdan, Y.A. Fast red emitting plastic scintillator. Nucl. Instrum. Methods 1980, 178, 411–413. [Google Scholar] [CrossRef]
  10. Montbarbon, E.; Amiot, M.-N.; Tromson, D.; Gaillard, S.; Frangville, C.; Woo, R.; Bertrand, G.H.V.; Pansu, R.B.; Renaud, J.-L.; Hamel, M. Large irradiation doses can improve the fast neutron/gamma discriminating capability of plastic scintillators. Phys. Chem. Chem. Phys. 2017, 19, 28105–28115. [Google Scholar] [CrossRef]
  11. Hamel, M.; Trocmé, M.; Rousseau, A.; Darbon, S. Red-emitting liquid and plastic scintillators with nanosecond time response. J. Lumin. 2017, 190, 511–517. [Google Scholar] [CrossRef]
  12. Tanaka, K.; Yanagida, T.; Hirose, A.; Yamane, H.; Yoshii, R.; Chujo, Y. Synthesis and color tuning of boron diiminate conjugated polymers with aggregation-induced scintillation properties. RSC Adv. 2015, 5, 966563. [Google Scholar] [CrossRef]
  13. Ponomarenko, S.A.; Surin, N.M.; Borshchev, O.V.; Luponosov, Y.N.; Akimov, D.Y.; Alexandrov, I.S.; Burenkov, A.A.; Kovalenko, A.G.; Stekhanov, V.N.; Kleymyuk, E.A.; et al. Nanostructured organosilicon luminophores and their application in highly efficient plastic scintillators. Sci. Rep. 2014, 4, 6549. [Google Scholar] [CrossRef] [Green Version]
  14. Huijun, Y.; Xiangtuo, W.; Yuying, J.; Yuanli, Z. Energy transfer in multi component plastic scintillators. J. Lumin. 1984, 31-32, 833–835. [Google Scholar] [CrossRef]
  15. Dalla Palma, M.; Quaranta, A.; Marchi, T.; Collazuol, G.; Carturan, S.; Cinausero, M.; Degerlier, M.; Gramegna, F. Red Emitting Phenyl-Polysiloxane Based Scintillators for Neutron Detection. IEEE Trans. Nucl. Sci. 2014, 61, 2052–2058. [Google Scholar] [CrossRef]
  16. Huijun, Y. Fast red-emitting plastic scintillators. He Dianzixue Yu Tance Jishu. Yuanzineng Chubanshe: Beijing, China. 1990, 10, 353–355. [Google Scholar]
  17. Adadurov, A.F.; Zhmurin, P.N.; Lebedev, V.N.; Kovalenko, V.V. Plastic scintillator with phosphorescent dopants for α-particles registration. Nucl. Instrum. Methods A 2010, 621, 354–357. [Google Scholar] [CrossRef]
  18. Sytnik, A.; Kasha, M. Spectroscopic criteria for wavelength shifting, fast, and red-infrared scintillators. Radiat. Phys. Chem. 1993, 41, 331–349. [Google Scholar] [CrossRef]
  19. Tanaka, K.; Yanagida, T.; Yamane, H.; Hirose, A.; Yoshii, R.; Chujo, Y. Liquid scintillators with near infrared emission based on organoboron conjugated polymers. Bioorg. Med. Chem. Lett. 2015, 25, 5331–5334. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  20. Shakirova, J.R.; Grachova, E.V.; Melekhova, A.A.; Krupenya, D.V.; Gurzhiy, V.V.; Karttunen, A.J.; Koshevoy, I.O.; Melnikov, A.S.; Tunik, S.P. Luminescent AuI—CuI Triphosphane Clusters That Contain Extended Linear Arylacetylenes. Eur. J. Inorg. Chem. 2012, 4048–4056. [Google Scholar] [CrossRef]
  21. Montbarbon, E.; Sguerra, F.; Bertrand, G.H.V.; Magnier, É.; Coulon, R.; Pansu, R.B.; Hamel, M. N-(2-ethylhexyl)carbazole: A new fluorophore highly suitable for liquid scintillation and n/γ discrimination. Chem.-Eur. J. 2016, 22, 12074–12080. [Google Scholar] [CrossRef]
  22. Ebran, A.; Taieb, J.; Belier, G.; Chatillon, A.; Laurent, B.; Martin, J.-F.; Pellereau, E. Picosecond resolution on relativistic heavy ions’ time-of-flight measurement. Nucl. Instrum. Methods A 2013, 728, 40–46. [Google Scholar] [CrossRef]
  23. Moszyński, M. Study of light collection process from cylindrical scintillators. Nucl. Instrum. Methods 1976, 134, 77–85. [Google Scholar] [CrossRef]
  24. Moszyński, M.; Bengtson, B. Status of timing with plastic scintillation detectors. Nucl. Instrum. Methods 1979, 158, 1–31. [Google Scholar] [CrossRef]
  25. Nanoled, pulsed laser and LED light sources. Available online: https://www.horiba.com/us/en/scientific/products/fluorescence-spectroscopy/lifetime/tcspc-components/nanoled/nanoled-618/ (accessed on 17 January 2022).
  26. Berlman, I.B.; Lutz, S.S.; Flournoy, J.M.; Ashford, C.B.; Franks, L.A.; Lyons, P.B. New fast organic scintillators using intramolecular bromine quenching. Nucl. Instrum. Methods 1984, 225, 78–84. [Google Scholar] [CrossRef]
  27. Andreeshchev, E.A.; Avedisyan, V.S.; Veronyan, S.M.; Zyablin, V.L.; Kovyrzina, K.A.; Kushakevich, Y.P.; Rozman, I.M.; Shoniya, V.M. SPS-B18 high-speed plastic scintillator. Instrum. Exp. Techn. 1988, 31, 593–595, Translated from Prib. Tekh. Eksp. 1988, 67–68. [Google Scholar]
  28. Lutz, S.S.; Franks, L.A.; Flournoy, J.M. High speed liquid scintillators for optical fiber applications. Nucl. Instrum. Methods 1982, 193, 623–629. [Google Scholar] [CrossRef]
  29. Zheng, H.; Baumbaugh, B.; Gerig, A.; Hurlbut, C.; Kauffman, J.; Marchant, J.; Pla-Dalmau, A.; Reynolds, K.; Ruchti, R.; Warchol, J.; et al. New scintillator and waveshifter materials. AIP Conf. Proc. 1998, 450, 371–380. [Google Scholar] [CrossRef]
  30. Bondarev, S.L.; Knyukshto, V.N.; Stepuro, V.I.; Stupak, A.P.; Turban, A.A. Fluorescence and electronic structure of the laser dye dcm in solutions and in polymethylmethacrylate. J. Appl. Spectrosc. 2004, 71, 194–201, Translated from Zh. Prikl. Spektrosk. 2004, 71, 179–186. [Google Scholar] [CrossRef]
  31. Muniz-Miranda, F.; Pedone, A.; Muniz-Miranda, M. Spectroscopic and DFT investigation on the photo-chemical properties of a push-pull chromophore: 4-Dimethylamino-4′-nitrostilbene. Spectrochim. Acta Part A 2018, 190, 33–39. [Google Scholar] [CrossRef] [PubMed]
  32. Papper, V.; Pines, D.; Likhtenshtein, G.; Pines, E. Photophysical characterization of trans-4,4′-disubstituted stilbenes. J. Photochem. Photobiol. A 1997, 111, 87–96. [Google Scholar] [CrossRef]
  33. Taniguchi, M.; Lindsey, J.S. Database of Absorption and Fluorescence Spectra of >300 Common Compounds for use in PhotochemCAD. Photochem. Photobiol. 2018, 94, 290–327. [Google Scholar] [CrossRef] [Green Version]
  34. BC-430 plastic scintillator. Available online: https://www.crystals.saint-gobain.com/sites/imdf.crystals.com/files/documents/bc430-data-sheet.pdf (accessed on 17 January 2022).
  35. Li, Y.; Chen, L.; Gao, R.; Liu, B.; Zheng, W.; Zhu, Y.; Ruan, J.; Ouyang, X.; Xu, Q. Nanosecond and highly Sensitive Scintillator Based on All-Inorganic Perovskite Single Crystals. ACS Appl. Mater. Interfaces 2021, 14, 1489–1495. [Google Scholar] [CrossRef] [PubMed]
Scheme 1. Preparation of 4-bromo-p-terphenyl.
Scheme 1. Preparation of 4-bromo-p-terphenyl.
Chemosensors 10 00086 sch001
Figure 1. Excitation profiles of the two NanoLEDs used in this experiment, dashed line: 274 nm, solid line: 368 nm. Inset: focus on the afterpulses.
Figure 1. Excitation profiles of the two NanoLEDs used in this experiment, dashed line: 274 nm, solid line: 368 nm. Inset: focus on the afterpulses.
Chemosensors 10 00086 g001
Figure 2. 90Sr/90Y radioluminescence of binary mixtures compared with commercial plastics.
Figure 2. 90Sr/90Y radioluminescence of binary mixtures compared with commercial plastics.
Chemosensors 10 00086 g002
Figure 3. Photoluminescence quenching of a plastic scintillator composed of PS + p-terphenyl 1.5 wt % + DANS 0.01 wt % with different amounts of benzophenone (top), piperidine (middle), or Hünig’s base (bottom). The same unquenched, reference material is added on each figure in light blue color (τex = 274 nm; τobs = 560 nm).
Figure 3. Photoluminescence quenching of a plastic scintillator composed of PS + p-terphenyl 1.5 wt % + DANS 0.01 wt % with different amounts of benzophenone (top), piperidine (middle), or Hünig’s base (bottom). The same unquenched, reference material is added on each figure in light blue color (τex = 274 nm; τobs = 560 nm).
Chemosensors 10 00086 g003
Figure 4. Time-resolved emission spectroscopy of 0.03 wt % 4-dimethylamino-4′-nitrostilbene in toluene, quenched with 5 wt % of Hünig’s base. τmean = 1.50 ns (λex = 368 nm).
Figure 4. Time-resolved emission spectroscopy of 0.03 wt % 4-dimethylamino-4′-nitrostilbene in toluene, quenched with 5 wt % of Hünig’s base. τmean = 1.50 ns (λex = 368 nm).
Chemosensors 10 00086 g004
Figure 5. Scintillators composed of polystyrene containing p-terphenyl, DANS, and quenchers, under visible light (left) and 368 nm UV (right), pictured 18 months after preparation. B, P, and H stand for benzophenone, piperidine, and Hünig’s base, respectively with their added concentration in wt %.
Figure 5. Scintillators composed of polystyrene containing p-terphenyl, DANS, and quenchers, under visible light (left) and 368 nm UV (right), pictured 18 months after preparation. B, P, and H stand for benzophenone, piperidine, and Hünig’s base, respectively with their added concentration in wt %.
Chemosensors 10 00086 g005
Figure 6. Fluorescence spectroscopy of p-terphenyl + DANS scintillators quenched with various amounts of quenchers: benzophenone (B series), piperidine (P series), or Hünig’s base (H series). λex = 370 nm. Values of the legend are in wt %.
Figure 6. Fluorescence spectroscopy of p-terphenyl + DANS scintillators quenched with various amounts of quenchers: benzophenone (B series), piperidine (P series), or Hünig’s base (H series). λex = 370 nm. Values of the legend are in wt %.
Chemosensors 10 00086 g006
Table 1. Main plastic and liquid scintillators. Only scintillators operating at λ em max > 550   nm are cited. The list is sorted in ascending emission wavelength.
Table 1. Main plastic and liquid scintillators. Only scintillators operating at λ em max > 550   nm are cited. The list is sorted in ascending emission wavelength.
StateLast Fluorophore λ e m m a x   ( nm ) Light Output (ph/MeV)Decay Time (ns)cRef.
YAG:Ce Y3Al5O12(Ce)550800070-
PVT scintillatorBC-430580690016.8-
Polymer thin film Chemosensors 10 00086 i001584n.d. a0.46 (60) + 1.0 (40)[12]
Polystyrene scintillator Chemosensors 10 00086 i0025889780n.d.[13]
Polystyrene scintillator Chemosensors 10 00086 i003591809.22–13.26[7]
Polystyrene scintillator Chemosensors 10 00086 i004595n.d.5.94[14]
Polystyrene scintillator Chemosensors 10 00086 i005>600n.d.5[9]
Polysiloxane scintillatorLumogen Red≈6008300n.d.[15]
Polystyrene scintillator Chemosensors 10 00086 i006600≈16,000≈6[3]
PMMA scintillatorCsPbBr3 Perovskite +
Chemosensors 10 00086 i007
≈600≈90003.4 (87) + 14.1 (13)[5]
Poly(styrene-co-acrylonitrile) scintillator Chemosensors 10 00086 i008≈610n.d.n.d.[16]
Polystyrene scintillator Chemosensors 10 00086 i0096145650 b469,000[17]
Sucrose octaacetate Chemosensors 10 00086 i01061837,50010.9 + 1960[6]
Polystyrene scintillator Chemosensors 10 00086 i011610–62070–3008.7[11]
PMMA scintillator Chemosensors 10 00086 i012≈620n.d.3.94[18]
Polymer in liquid Chemosensors 10 00086 i013750n.d.1.92[19]
a n.d.—not determined. b value obtained from 239Pu alpha excitation. c usually monoexponential. When it is biexponential, it is expressed at the percentage of the first and the second exponential in the global fit.
Table 2. Mono or biexponential fitting of the photoluminescence decay of molecules dissolved at 1 wt % in toluene (λex = 274 nm; λobs = λ em max ).
Table 2. Mono or biexponential fitting of the photoluminescence decay of molecules dissolved at 1 wt % in toluene (λex = 274 nm; λobs = λ em max ).
MoleculeStructureMono- or Biexponential τ (ns) a<τ> (ns) b
PPO Chemosensors 10 00086 i0142.272.27
1,1,4,4-tetraphenylbutadiene Chemosensors 10 00086 i0151.45 (99) + 34.7 (1)1.78
Biphenyl Chemosensors 10 00086 i0164.814.81
p-terphenyl Chemosensors 10 00086 i0171.451.45
p-quaterphenyl Chemosensors 10 00086 i0180.85 (73) + 1.82 (27)1.11
p-sexiphenyl Chemosensors 10 00086 i0191.67 (66) + 2.83 (34)2.06
m-terphenyl Chemosensors 10 00086 i0201.15 (59) + 8.96 (41)4.35
4-bromo-p-terphenyl Chemosensors 10 00086 i0210.72 (58) + 3.81 (42)2.01
4,4′-dibromo-p-terphenyl Chemosensors 10 00086 i0221.90 (64) + 12.54 (36)5.73
PMP1-phenyl-3-(mesityl)-2-pyrazoline Chemosensors 10 00086 i0234.114.11
Naphthalene Chemosensors 10 00086 i0248.678.67
Anthracene Chemosensors 10 00086 i0252.42 (90) + 8.51 (10)3.03
4-isopropylbiphenyl Chemosensors 10 00086 i0260.80 (5) + 4.94 (95)4.73
Pyrene Chemosensors 10 00086 i02723.023.0
N-ethylcarbazole Chemosensors 10 00086 i0287.917.91
N-(2-ethylhexyl)carbazole Chemosensors 10 00086 i02912.3012.30
BBD2,5-di(4′-biphenylyl)-1,3,4-oxadiazole Chemosensors 10 00086 i0301.351.35
PBD2-phenyl-5-(4′-biphenylyl)-1,3,4-oxadiazole Chemosensors 10 00086 i0311.511.51
Butyl-PBD2-(p-tert-butylphenyl-5-(4′-biphenylyl)-1,3,4-oxadiazole Chemosensors 10 00086 i0320.92 (54) + 1.64 (46)1.25
a When the fitting of the decay curve proved to be better expressed as a biexponential, the results are given according to the following: τfast (%fast) + τslow (%slow). b <τ> = τfast × %fast + τslow × %slow.
Table 3. Photoluminescence quenching of p-terphenyl or p-quaterphenyl with piperidine or benzophenone in toluene. λex = 274 nm; λobs = 342 nm (p-Terphenyl) or 386 nm (p-Quaterphenyl).
Table 3. Photoluminescence quenching of p-terphenyl or p-quaterphenyl with piperidine or benzophenone in toluene. λex = 274 nm; λobs = 342 nm (p-Terphenyl) or 386 nm (p-Quaterphenyl).
Molecule Quencher (wt %)τ (ns)<τ> (ns)
p-terphenyl-1.451.45
p-terphenylBenzophenone (0.4)0.59 (63.5) + 1.85 (36.5)1.05
p-terphenylPiperidine (1.6)0.60 (71) + 1.92 (29)0.98
p-terphenylHünig’s base (1.6)0.66 (78.6) + 2.11 (21.4)0.97
p-quaterphenyl-0.85 (73) + 1.82 (27)1.11
p-quaterphenylBenzophenone (0.4)0.77 (42.5) + 2.08 (57.5)1.52
p-quaterphenylPiperidine (1.6)1.731.73
p-quaterphenylHünig’s base (1.6)0.71 (48.5) + 4.44 (51.5)2.6
Table 4. Photoluminescence properties of several plastic-state binary mixtures, eventually quenched with benzophenone. λex = 274 nm; λobs = λ em max . All scintillators are with dimension Φ 49 mm h 10 mm.
Table 4. Photoluminescence properties of several plastic-state binary mixtures, eventually quenched with benzophenone. λex = 274 nm; λobs = λ em max . All scintillators are with dimension Φ 49 mm h 10 mm.
Composition *Mono- or Biexponential τ (ns) *<τ> (ns) λ e m m a x   ( nm ) FWHM (ns)
BC-422Q 1%0.78 (67) + 3.05 (32)1.523602.05
BC-422Q 2%0.81 (73) + 3.08 (27)1.424021.96
PVT p-Q 0.31.71 (52) + 11.6 (48)6.463702.58
PVT p-Q 0.61.50 (59) + 9.93 (41)4.693702.52
PVT p-Q 1.01.52 (66) + 8.41 (34)3.863702.52
PVT p-Q 0.6 B 0.61.23 (63) + 8.05 (37)3.863702.25
PS p-T 2 B 20.81 (48.5) + 4.09 (51.4)2.504102.08
PS 4-Br-p-T 0.50.56 (50) + 2.90 (34.9) + 10.9 (15.1)2.954001.71
PS 4-Br-p-T 1.00.99 (49.75) + 5.38 (50.25)3.194002.14
PS 4-Br-p-T 1.50.53 (46.5) + 2.80 (36.1) + 11.8 (17.4)3.314001.71
PS 4-Br-p-T 3.50.882 (73.9) + 4.00 (26.1)1.694002.00
* PVT: poly(vinyltoluene), PS: polystyrene, p-T: p-terphenyl, p-Q: p-quaterphenyl, 4-Br-p-T: 4-bromo-p-terphenyl, B: benzophenone. The numeral values of the first row are for the weight concentrations.
Table 5. Radioluminescence performances of selected plastic scintillators. All scintillators measure Φ 49 mm h 10 mm.
Table 5. Radioluminescence performances of selected plastic scintillators. All scintillators measure Φ 49 mm h 10 mm.
Composition * λ r a d i o l u m . m a x   ±   2   ( nm ) Radioluminescence vs. BC-422Q 1% (%)Light Yield ϕ vs. BC-422Q 1% (ph/MeV)ϕ/<τ>
(ph/MeV/ns)
BC-422Q 1%40010017001118
BC-422Q 2%40656290204
PVT p-Q 0.33941401940300
PVT p-Q 0.64021181310279
PVT p-Q 1.03982292840735
PVT p-Q 0.6 B 0.639687610158
PS 4-Br-p-T 1.039452700219
PS 4-Br-p-T 3.53969018701106
* See Table 4 for abbreviations.
Table 6. Main photophysical characteristics of red-emitting molecules dissolved at 0.03 wt % in air-saturated toluene solutions (λex = 368 nm; λobs = λ em max ).
Table 6. Main photophysical characteristics of red-emitting molecules dissolved at 0.03 wt % in air-saturated toluene solutions (λex = 368 nm; λobs = λ em max ).
#MoleculeStructure λ e m m a x   ( nm ) τ (ns)
1Nile red Chemosensors 10 00086 i0336105.18
2DCM4-(Dicyanomethylene)-2-methyl-6-(4-dimethylaminostyryl)-4H-pyran Chemosensors 10 00086 i0345500.95
3Rubrene Chemosensors 10 00086 i03558427.3
4N,N′-Bis(2,5-di-tert-butylphenyl)-3,4,9,10-perylenedicarboximide Chemosensors 10 00086 i0365806.6
5N,N′-Bis-n-pentyl-1,6,7,12-tetrachloro-3,4,9,10-perylenedicarboximide Chemosensors 10 00086 i03759611.4
6Pyrromethene 605Difluoro [2-(4-ethyl-3,5-dimethyl-1H-pyrrol-2-yl-κN)-2-(4-ethyl-3,5-dimethyl-2H-pyrrol-2-ylidene-κN)ethyl acetato])boron Chemosensors 10 00086 i03858612.4
7Pyrromethene 597Difluoro(4-(1,1-dimethylethyl)-2-{1-[4-(1,1-dimethylethyl)-3,5-dimethyl-2H-pyrrol-2-ylidene-N]ethyl}-3,5-dimethyl-1H-pyrrol-2-ylidene-N]ethyl}-3,5-dimethyl-1H-pyrrolato-N)boron Chemosensors 10 00086 i03960813.8
8DANSTrans-4-dimethylamino-4′-nitrostilbene Chemosensors 10 00086 i0405603.28
Table 7. Comparison of relevant photophysical data of DCM under various conditions.
Table 7. Comparison of relevant photophysical data of DCM under various conditions.
Matrix λ e m m a x   ( nm ) τ (ns)Quantum Yield
PMMABibliography5502.00.76
PMMAMeasurement5502.63n.d.
TolueneBibliography5670.020.08
StyreneMeasurement5500.95n.d.
PolystyreneMeasurement5503.80n.d.
n.d.: not determined.
Table 8. Quenching of trans-4-dimethylamino-4′-nitrostilbene with various quenchers. Solvent toluene. λex = 368 nm; λobs = 560 nm.
Table 8. Quenching of trans-4-dimethylamino-4′-nitrostilbene with various quenchers. Solvent toluene. λex = 368 nm; λobs = 560 nm.
Quencher Concentration (wt %)τ (ns)<τ> (ns)FWHM ± 0.05 (ns)
-03.28 5.00
Benzophenone1.63.37 4.78
Benzophenone4.83.44 (89.1) + 61.1 (10.9)9.724.72
Piperidine1.62.02 3.13
Piperidine4.80.91 (72.8) + 2.39 (27.2)1.312.25
Hünig’s base1.62.16 3.24
Hünig’s base4.81.17 (91.8) + 5.14 (8.2)1.502.41
Table 9. Photoluminescence and scintillation properties of red and fast plastic scintillators compared with BC-430 and BC-422Q 1%. For the TCSPC values: λobs = 560 nm. All scintillators are with dimension Φ 49 mm h 30 mm, except BC-430 which is Φ 50 mm h 50 mm, and BC-422Q 1% which is Φ 50 mm h 15 mm.
Table 9. Photoluminescence and scintillation properties of red and fast plastic scintillators compared with BC-430 and BC-422Q 1%. For the TCSPC values: λobs = 560 nm. All scintillators are with dimension Φ 49 mm h 30 mm, except BC-430 which is Φ 50 mm h 50 mm, and BC-422Q 1% which is Φ 50 mm h 15 mm.
Plastic Scintillator a λ e m m a x ( nm )   b τ (ns)
λex 274 nm
FWHM
± 0.11 (ns)
ϕ (ph/MeV) cϕ
(ph/MeV) d
ϕ/<τ>
(ph/MeV/ns) e
BC-43058012.523.0069006900552
BC-422Q 1%3801.522.05n.d. f17001118
PS + p-T 1.5 + DCM (2) 0.015643.08 (85.5) + 22.1 (14.5)5.1513001120192
PS + p-T 1.5 + DCM (2) 0.035743.27 (89.7) + 22.4 (10.3)5.2715001430273
PS + p-T 1.5 + DCM (2) 0.055783.42 (92.5) + 23.0 (7.5)5.2713001220250
PS + 4-Br-p-T 1.5 + DCM (2) 0.03 + B 25603.302.08n.d.360109
PS + p-T 1.5 + 3 0.0158223.7825.3523302850120
PS + p-T 1.5 + 3 0.0359027.3540.712500256094
PS + p-T 1.5 + 3 0.0559029.1937.642460245084
PS + p-T 1.5 + 4 0.015787.27 (95.3) + 41.8 (4.7)8.3436704370491
PS + p-T 1.5 + 4 0.035829.52 (73.15) + 34.9 (26.85)11.8544004860297
PS + p-T 1.5 + 4 0.055929.44 (52.65) + 35.0 (47.35)12.0737004290199
PS + p-T 1.5 + 5 0.0158210.8212.9432102510232
PS + p-T 1.5 + 5 0.0359211.4415.2532403070268
PS + p-T 1.5 + 5 0.0559611.5913.5032403220278
PS + p-T 1.5 + 7 0.0159612.419.2042503800306
PS + p-T 1.5 + 7 0.0360213.820.7445004610334
PS + p-T 1.5 + 7 0.0560413.922.9950705160371
PS + p-T 1.5 + DANS 0.015544.237.13628061001442
PS + p-T 1.5 + DANS 0.035704.407.68547053901225
PS + p-T 1.5 + DANS 0.055724.687.90548056001196
a PS: polystyrene; p-T: p-terphenyl; 4-Br-p-T: 4-bromo-p-terphenyl; DCM: 4-(dicyanomethylene)-2-methyl-6-(4-dimethylaminostyryl)-4H-pyran; DANS: trans-4-dimethylamino-4′-nitrostilbene; B: benzophenone; P: piperidine; H: Hünig’s base. The values of the first row are for the weight concentrations. The numbers in bold font refer to the red-emitting fluorophores described in Table 6. b values in radioluminescence. c estimated by beta-induced pulse height spectroscopy. The relative is calculated by a rule of thumb between BC-430 light yield reference [34]. d estimated by radioluminescence. The relative light yield is calculated by a rule of thumb between BC-430 light yield reference, its radioluminescence integral, and the other sample’s integral. e the light yield recorded from radioluminescence was used in this calculation. f n.d.: not determined.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Hamel, M. Progress in Fast and Red Plastic Scintillators. Chemosensors 2022, 10, 86. https://0-doi-org.brum.beds.ac.uk/10.3390/chemosensors10020086

AMA Style

Hamel M. Progress in Fast and Red Plastic Scintillators. Chemosensors. 2022; 10(2):86. https://0-doi-org.brum.beds.ac.uk/10.3390/chemosensors10020086

Chicago/Turabian Style

Hamel, Matthieu. 2022. "Progress in Fast and Red Plastic Scintillators" Chemosensors 10, no. 2: 86. https://0-doi-org.brum.beds.ac.uk/10.3390/chemosensors10020086

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop