Next Article in Journal
Protein Determination—Method Matters
Previous Article in Journal
Food Composition Databases: Considerations about Complex Food Matrices
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Determination of Vitamin E in Cereal Products and Biscuits by GC-FID

1
General Chemical Lab of Research and Analysis of Lamia, Timfristou 181, 35100 Lamia, Greece
2
Chemical Laboratory of Lamia, Karaiskaki 85, 35100 Lamia, Greece
3
Artolife-Bionatural SA, ArmaThivon, 32200 Thiva, Greece
4
Food Chemistry Laboratory, Department of Chemistry, National and Kapodistrian University of Athens, Panepistimiopolis Zografou, 15771 Athens, Greece
*
Author to whom correspondence should be addressed.
Submission received: 13 September 2017 / Revised: 13 December 2017 / Accepted: 14 December 2017 / Published: 1 January 2018

Abstract

:
A rapid, precise and accurate method for the determination of vitamin E (α-tocopherol) in cereal products and biscuits has been developed. The uncertainty was calculated for the first time, and the methods were performed for different cereal products and biscuits, characterized as “superfoods”. The limits of detection and quantification were calculated. The accuracy and precision were estimated using the certified reference material FAPAS T10112QC, and the determined values were in good accordance with the certified values. The health claims according to the daily reference values for vitamin E were calculated, and the results proved that the majority of the samples examined showed a percentage daily value higher than 15%.

1. Introduction

Vitamin E is a fat-soluble vitamin found in many foodstuffs, such as cereals, eggs, olive oils, and vegetables. Vitamin E occurs in many different forms (α-, β-, γ- and δ-tocopherols and α-, β-, γ- and δ-tocotrienols) and has many health benefits; it is mostly used for treating and preventing heart diseases [1,2]. It is a well-known antioxidant, preventing different types of cancer, such as lung and oral cancer and others. It is also believed to help patients with Alzheimer’s disease and other types of diseases related to the nervous system. According to the European Regulation 1169/2011 on the provision of food information to consumers, there is a daily reference intake for vitamin E equal to 12 mg per 100 g. As a rule, to decide whether a food has a significant amount of vitamin E, it must contain 15% of the reference dose per 100 g, or 1.8 mg per 100 g [3]. The claim suggests that “vitamin E contributes to the protection of cells from oxidative stress” and can only be used for food that is at least a source of vitamin E.
Nowadays, there is a great interest in functional foods, commonly known as “superfoods”. There is no clear definition for superfoods; it is a term used for foods that combine the nutritional health benefits and disease prevention of different foods [4]. These foods are mainly composed of cereals, fruits, beans and vegetable oils [5,6,7,8,9,10]. Vitamin E occurs in all these foodstuffs, but its content depends on the superfood composition. For this reason, it is of great importance to determine the appropriate content of the different food components in order to take the recommended daily dose of vitamin E without spoiling the taste or the flavor of the foodstuffs.
There are many methods for the determination of vitamin E. Liquid and gas chromatography methods with different detectors are the most common methods used nowadays for the determination of fat-soluble vitamins [11,12,13,14,15,16]. The need for the simultaneous determination of the majority of vitamins has led to the use of modern analytical methods with low limits of detection, such as Liquid Chromatography tandem mass spectroscopy (LC-MS/MS), Liquid chromatography mass spectrometry (LC-MS) and Gas Chromatography (GC × GC) methods [17,18,19]. All these methods require complicated preparation steps in order to decrease the interferences provided by the matrix.
In this article, a rapid, precise and accurate method for the determination of vitamin E in cereal products by Gas Chromatography coupled to Flame ionization Detection (GC-FID) is presented. The method is based on the method presented by Pyka et al. (2001) for the determination of α-tocopherol in human plasma and has now been modified and expanded for the determination of α-tocopherol in cereal products and biscuits [1]. The developed method is simple and rapid and can be applied for the determination of α-tocopherol in cereal products and biscuits with low limits of detection and high accuracy and precision. The method was applied in a vast number of new nutraceutical and functional cereal products and biscuits that can be characterized as superfoods, and possible health claims were examined.

2. Materials and Methods

2.1. Chemicals

All reagents used were of analytical grade. Vitamin E standard solution and ethanol were purchased from Sigma-Aldrich (Darmstadt, Germany). Hexane was purchased from VWR (Brooklyn, NY, USA) and dichloromethane was purchased from Lach-ner, s.r.o. (Neratovice, Czech Republic).

2.2. Instumentation

All experiments were performed with a Shimadzu GC 2010 PLUS, GC-FID system, using an Agilent DB-1 (30 m × 0.32 mm × 1 μm). The optimized conditions were as follows: injection volume of 2 μL in splitless mode; pulse time of 1.0 min; injector temperature of 300 °C; carrier gas: He at a constant flow of 2.0 mL/min; detector temperature of 340 °C. The initial oven temperature, 120 °C, was held for 1 min and was then programmed at 27 °C/min to 320 °C, at which it was held for 15 min.

2.3. Sample Preparation

Eighteen different cereal and bakery products, belonging to the class of superfoods were selected for the vitamin analysis. The ingredients of each product are presented in Table 1. The samples were milled and well homogenized. A sample amount of a well-homogenized cereal product (0.5000 g) was diluted in 1 mL of ethanol and left overnight in the dark. The solution was then mixed well with an appropriate amount of hexane and dichlomethane (90%/10% v/v) and centrifuged at 2500 rpm for 10 min, and the hexane/dichloromethne stage was evaporated to dryness at 40 °C. Finally the sample was dissolved in 1 mL of ethanol, and 2 μL was injected into the GC system.

2.4. Method Validation

Quantification was performed by different dilutions of the stock solution (from 0.5 to 250 mg/L). Every standard solution was measured in triplicate. Limit of Detection (LOD) and Limit of Quantification (LOQ) were calculated by the standard deviation of the intercept. Precision and accuracy experiments were carried out, and the relative standard deviation (%RSD) values were calculated from the multiple analysis of the certified reference material (FAPAS T10112QC) (n = 6) under repeatability and reproducibility conditions. The uncertainty of the method was also calculated on the basis of the Eurachem/Citac Guidelines [20].

3. Results and Discussion

3.1. The Results of Method Validation

For the determination of α-tocopherol, content quantification was performed by plotting the concentration (C) of different calibration standards (0.5–50 mg/L) versus the peak area of the analyte (PA). The equation of the calibration curve was found to be PA = (7.08 ± 0.16) × 104C (mg/L) (1.5 ± 3.0) × 103, R2 = 0.998. It must be noted that an internal quality control sample was measured every 10 samples in order to avoid the use of an internal standard. All samples and the standard solution were measured in triplicate.
The instrumental LOD and LOQ were determined by the standard deviation of the intercept of the calibration curve and were equal to 0.17 and 0.51 mg/L. The respective methods, LOD and LOQ, were found to give values equal to 0.34 and 1.0 mg/kg. These values were 2 or 3 times higher compared to values given by other chromatographic techniques, such as High Performance Liquid chromatography-Fluorescence detection (HPLC-FLD), and they were much higher than that given by Ultra Performance Liquid chromatography-electrospray ionization-tandem mass spectrometry UPLC-ESI/MSn [21,22]. However, the calculated LOD value was considered “fit-for-purpose”, taking into account the reference daily dose of 18 mg/kg as provided in the European Regulation 1169/2011 [3].
Precision experiments were carried out, and the relative standard deviation (%RSD) values achieved from three different concentration levels measured six times under repeatability conditions and six times over two different days under reproducibility conditions were lower than 10% for all the different concentration levels. The repeatability HORRATr and reproducibility HORRATR values (the observed RSDr divided by the RSDr value estimated from the Horwitz equation using the assumption r = 0.66R) achieved from these different concentration levels ranged from 0.18 to 0.25. These values were lower than the crucial value of 2, and the method was fit-for-purpose. For accuracy estimation, the certified reference material FAPAS T10112QC with a certified value of 49.0 ± 12.5 was analyzed six times over two different days by two different analysts (n = 12), and the recovery was found to be equal to 99.5 ± 5.9 (Figure 1). The recovery data were within ±25% of the target value, as provided by the certification of the reference material, and for this reason, the method was again considered as fit-for-purpose.
The uncertainty of the method was also calculated on the basis of the Eurachem/Citac Guidelines [18]. The calculated expanded uncertainties were found to be equal to 15.0%, 12.3% and 8.50% of the content of the analyte in milligrams per kilogram for the LOQ, the centroid of the calibration curve, and the upper limit of the linear range, respectively (k = 2, Confidence Limit (CL) = 95%). The main sources of the calculated uncertainty were the calibration uncertainty, the bias uncertainty and the precision uncertainty.

3.2. Determination of α-Tocopherol Content and Diastase Activity in Real Samples Characterized as Superfoods

The method was performed for the determination of vitamin E in 18 different superfoods produced under ISO 22000 recommendations from Artolife SA, Thiva, Greece. The results proved that the content of α-tocopherol ranged from 4.00 to 88.0 mg/kg. The highest content of vitamin E was found in the sample coded as S13, made from zea wheat (Triticum dicoccum) and vanilla. Vanilla contains a high amount of vitamin E, approximately equal to 54.0 mg/kg [23], and Triticum dicoccum wheat also contains a high amount of vitamin E (approximately equal to 10 mg/kg) [24,25]. It seemed that the temperature during biscuit making did not lead to a great loss of vitamin E. Similar results of vitamin E loss during bread making were also reported by Leenhardt et al. (2006) [24]. The lowest content of vitamin E was found in the sweet bun made from plums, figs and dates (S4 sample), for which the content was approximately equal to the sum of each ingredient’s content. All superfoods containing nuts and almonds gave a high content of vitamin E, as nuts are commonly known for their vitamin E content. The vitamin E content also depended on the vegetable oils used for the preparation of the bakery products. Sunflower oil was used in the preparation of the sweet buns, breadsticks and biscuits using the same amount in order to obtain comparative results.
With regard to the Regulation (European Union, EU) No. 1169/2011 of the European Parliament and of the Council on the provision of food information to consumers, vitamin E may be declared on the foodstuffs according to their nutrient reference intake [3]. A significant amount of the vitamin can be declared only if a foodstuff contains 15% of the nutrient reference values specified in the current regulation. For vitamin E, the reference intake value is equal to 120 mg/kg, or 15% of the reference intake is equal to 18 mg/kg. According to the Commission Regulation (EU) No. 432/2012, establishing a list of permitted health claims made on foods, other than those referring to the reduction of disease risk and to children’s development and health, the following health claim can be used for a foodstuff containing vitamin E levels higher than the 15% of the reference daily intake: “Vitamin E contributes to the protection of cells from oxidative stress” [26]. Taking into account the serving size of 100 g, the samples coded as S1, S2, S9, S10 and S11 cannot use this specific health claim. In particular, for the sweet bun with plums, nuts, and dates (S12) and biscuits with zea wheat and vanilla, the health claim (S13) can also be used, as well as for the serving size of 35 g (1 biscuit). Summarizing, in the majority of the samples (over 72%), the following health claim can be used on the labeling: “Vitamin E contributes to the protection of cells from oxidative stress”.

4. Conclusions

The method presented in this application can be used for the determination of vitamin E in cereal and biscuit products by GC-FID. The GC-FID method proposed is considered fit-for-purpose in terms of precision and accuracy. The results prove that the majority of cereal products are rich in vitamin E. The health claim for vitamin E as specified in Commission Regulation (EU) No. 432/2012 can be used for the majority of the samples. Vanilla and nuts seem to give an excessive amount of vitamin E in bakery products, whereas bakery products containing only fruits seem to give a lower content.

Acknowledgments

Authors would like to thank the company Artolife S.A., Arma Thivwn 32200, Thiva, Greece for biscuits and cereals supply.

Author Contributions

I.N.P., L.P. and C.P. performed the analysis, I.N.K. and L.P. provided the samples, I.N.P. and C.P. have written the article, C.P. is the supervisor of article submission.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Pyka, A.; Sliwiok, J. Chromatographic separation of tocopherols. J. Chromatogr. A 2001, 935, 71–76. [Google Scholar] [CrossRef]
  2. Zhao, Y.; Monahan, F.J.; McNulty, B.A.; Gibney, M.J.; Gibney, E.R. Effect of vitamin E intake from food and supplement sources on plasma a- and g-tocopherol concentrations in a healthy Irish adult population. Br. J. Nutr. 2014, 112, 1575–1585. [Google Scholar] [CrossRef] [PubMed]
  3. Provision of Food Information to Consumers. Commission Regulation (EU) No. 1169/2011 of the European Parliament and of the Council of 25 October 2011. Official Journal of the European Union L 304/18-63. Available online: http://eur-lex.europa.eu/legal-content/EN/ALL/?uri=CELEX%3A32011R1169 (accessed on 25 October 2011).
  4. Lunn, J. Superfoods. Nutr. Bull. 2006, 31, 171–172. [Google Scholar] [CrossRef]
  5. Salvo, A.; La Torre, G.L.; Rotondo, A.; Mangano, V.; Casale, K.E.; Pellizzeri, V.; Clodoveo, M.L.; Corbo, F.; Cicero, N.; Dugo, G. Determination of Squalene in Organic Extra Virgin Olive Oils (EVOOs) by UPLC/PDA Using a Single-Step SPE Sample Preparation. Food Anal. Methods 2017, 10, 1377–1385. [Google Scholar] [CrossRef]
  6. Salvo, A.; Rotondo, A.; La Torre, G.L.; Cicero, N.; Dugo, G. Determination of 1,2/1,3-diglycerides in Sicilian extra-virgin olive oils by 1H-NMR over a one-year storage period. Nat. Prod. Res. 2017, 31, 822–828. [Google Scholar] [CrossRef] [PubMed]
  7. Rotondo, A.; Salvo, A.; Gallo, V.; Rastrelli, L.; Dugo, G. Quick unreferenced NMR quantification of Squalene in vegetable oils. Eur. J. Lipid Sci. Technol. 2017. [Google Scholar] [CrossRef]
  8. Dugo, G.; Rotondo, A.; Mallamace, D.; Cicero, N.; Salvo, A.; Rotondo, E.; Corsaro, C. Enhanced detection of aldehydes in extra-virgin olive oil by means of band selective NMR spectroscopy. Phys. A Stat. Mech. Its Appl. 2015, 420, 258–264. [Google Scholar] [CrossRef]
  9. Rotondo, A.; Salvo, A.; Giuffrida, D.; Dugo, G.; Rotondo, E. NMR analysis of aldehydes in sicilian extra-virgin olive oils by DPFGSE techniques. AAPP Phys. Math. Nat. Sci. 2011, 89. [Google Scholar] [CrossRef]
  10. Giuffrida, D.; Salvo, F.; Salvo, A.; Cossignani, L.; Dugo, G. Pigments profile in monovarietal virgin olive oils from various Italian olive varieties. Food Chem. 2011, 124, 1119–1123. [Google Scholar] [CrossRef]
  11. Rizzolo, A.; Polesello, S. Chromatographic determination of vitamins in foods. J. Chromatogr. A 1992, 624, 103–152. [Google Scholar] [CrossRef]
  12. Ball, G.F.M. Vitamins in Foods, Analysis, Bioavailability and Stability; CRC: London, UK, 2006. [Google Scholar]
  13. Blake, C.J. Status of Methodology for the Determination of Fat-Soluble Vitamins in Foods, Dietary Supplements, and Vitamin Premixes. J. AOAC Int. 2007, 90, 897–910. [Google Scholar] [PubMed]
  14. Cerretani, L.; Lerma-García, M.J.; Herrero-Martínez, J.M.; Gallina-Toschi, T.; Simó-Alfonso, E.F. Determination of Tocopherols and Tocotrienols in Vegetable Oils by Nanoliquid Chromatography with Ultraviolet−Visible Detection Using a Silica Monolithic Column. J. Agric. Food Chem. 2010, 58, 757–761. [Google Scholar] [CrossRef] [PubMed]
  15. Kadioglu, Y.; Demirkaya, F.; Demirkaya, A.K. Quantitative Determination of Underivatized α-Tocopherol in Cow Milk, Vitamin and Multivitamin Drugs by GC-FID. Chromatographia 2009, 70, 665–670. [Google Scholar] [CrossRef]
  16. Gómez-Caravaca, A.M.; Verardo, V.; Caboni, M.F. Chromatographic techniques for the determination of alkyl-phenols, tocopherols and other minor polar compounds in raw and roasted cold pressed cashew nut oils. J. Chromatogr. A 2010, 1217, 7411–7417. [Google Scholar] [CrossRef] [PubMed]
  17. Vaule, H.; Leonard, S.W.; Traber, M.G. Vitamin E delivery to human skin: Studies using deuterated α-tocopherol measured by APCI LC-MS. Free Radic. Biol. Med. 2004, 36, 456–463. [Google Scholar] [CrossRef] [PubMed]
  18. Bursal, E.; Köksal, E.; Gülçin, İ.; Bilsel, G.; Gören, A.C. Antioxidant activity and polyphenol content of cherry stem (Cerasus avium L.) determined by LC–MS/MS. Food Res. Int. 2013, 51, 66–74. [Google Scholar] [CrossRef]
  19. Tranchida, P.Q.; Salivo, S.; Bonaccorsi, I.; Rotondo, A.; Dugo, P.; Mondello, L. Analysis of the unsaponifiable fraction of lipids belonging to different milk-types by using a comprehensive two-dimensional gas chromatography with dual mass spectrometry/flame ionization detection and with the support of high resolution time-of-flight mass spectrometry for structural elucidation. J. Chromatogr. A 2013, 1313, 194–201. [Google Scholar] [PubMed]
  20. Ellison, S.L.R.; Rosslein, M.; Williams, A. Quantifying Uncertainty in Analytical Measurement, 2nd ed.; Eurachem/Citac Guide CG4; Eurachem: Olomouc, Czech Republic, 2000. (In English) [Google Scholar]
  21. Górnas, P.; Pugajeva, I.; Segliņa, D. Seeds recovered from by-products of selected fruit processing as a rich source of tocochromanols: RP-HPLC/FLD and RP-UPLC-ESI/MSn. Eur. Food Res. Technol. 2014, 239, 519–524. [Google Scholar] [CrossRef]
  22. Górnas, P. Unique variability of tocopherol composition in various seed oils recovered from by-products of apple industry: Rapid and simple determination of all four homologues (a, b, c and d) by RP-HPLC/FLD. Food Chem. 2015, 172, 129–134. [Google Scholar] [CrossRef] [PubMed]
  23. Sundl, I.; Murkovic, M.; Bandoniene, D.; Winklhofer-Roob, B.M. Vitamin E content of foods: Comparison of results obtained from food composition tables and HPLC analysis. Clin. Nutr. 2007, 26, 145–153. [Google Scholar] [CrossRef] [PubMed]
  24. Leenhardt, F.; Lyan, B.; Rock, E.; Boussard, A.; Potus, J.; Chanliaud, E.; Remesy, C. Wheat Lipoxygenase Activity Induces Greater Loss of Carotenoids than Vitamin E during Breadmaking. J. Agric. Food Chem. 2006, 54, 1710–1715. [Google Scholar] [CrossRef] [PubMed]
  25. Hejtmánková, K.; Lachman, J.; Hejtmánková, A.; Pivec, V.; Janovská, D. Tocols of selected spring wheat (Triticum aestivum L.), einkorn wheat (Triticum monococcum L.) and wild emmer (Triticum dicoccum Schuebl [Schrank]) varieties. Food Chem. 2010, 123, 1267–1274. [Google Scholar]
  26. Commission Regulation (EU) No 432/2012 of 16 May 2012 Establishing a List of Permitted Health Claims Made on Foods, Other Than Those Referring to the Reduction of Disease Risk and to Children’s Development and Health. Available online: http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=OJ:L:2012:136:0001:0040:en:PDF (accessed on 16 May 2012).
Figure 1. Chromatogram of the certified reference material (CRM; pink line) and a standard solution containing 50 mg/L vitamin E (black line).
Figure 1. Chromatogram of the certified reference material (CRM; pink line) and a standard solution containing 50 mg/L vitamin E (black line).
Foods 07 00003 g001
Table 1. Mean content of vitamin E in different cereal and bakery products.
Table 1. Mean content of vitamin E in different cereal and bakery products.
Sample TypeSample Coded AsIngredientsα-Tocopherol (mg/kg)% Daily Value
Sweet bunS1Oats and honey15.012.5
Sweet bunS2Plums, figs and dates4.003.30
Sweet bunS3Chocolate, bilberries and raspberries19.015.8
Sweet bunS4Nuts, oranges and molasses34.028.3
Sweet bunS5Nuts and chocolate31.226.0
Sweet bunS6Forest fruits33.227.6
Sweet bunS7Whole grain with fruits34.128.4
Sweet bunS8Almond50.241.8
Sweet bunS9Rye, plums, nuts and raisins6.125.10
Sweet bunS10Cereals and nuts10.08.30
Sweet bunS11Oats, apple and cinnamon10.58.80
Sweet bunS12Plums, nuts and dates60.050.0
BiscuitsS13Triticum dicoccum wheat and vanilla88.073.3
BreadstickS14Oats and wheat18.215.2
BreadstickS15Triticum dicoccum wheat, tomato and oregano24.220.2
BreadstickS16Triticum dicoccum wheat and sesame20.016.7
BreadstickS17Triticum dicoccum wheat, whole grain20.216.8
BreadstickS18Triticum dicoccum wheat and vegetables20.517.1

Share and Cite

MDPI and ACS Style

Pasias, I.N.; Kiriakou, I.K.; Papakonstantinou, L.; Proestos, C. Determination of Vitamin E in Cereal Products and Biscuits by GC-FID. Foods 2018, 7, 3. https://0-doi-org.brum.beds.ac.uk/10.3390/foods7010003

AMA Style

Pasias IN, Kiriakou IK, Papakonstantinou L, Proestos C. Determination of Vitamin E in Cereal Products and Biscuits by GC-FID. Foods. 2018; 7(1):3. https://0-doi-org.brum.beds.ac.uk/10.3390/foods7010003

Chicago/Turabian Style

Pasias, Ioannis N., Ioannis K. Kiriakou, Lila Papakonstantinou, and Charalampos Proestos. 2018. "Determination of Vitamin E in Cereal Products and Biscuits by GC-FID" Foods 7, no. 1: 3. https://0-doi-org.brum.beds.ac.uk/10.3390/foods7010003

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop