Next Article in Journal
Facilitating Prescribed Fire in Northern California through Indigenous Governance and Interagency Partnerships
Next Article in Special Issue
Forest Structure Drives Fuel Moisture Response across Alternative Forest States
Previous Article in Journal / Special Issue
Ignition of Fuel Beds by Cigarettes: A Conceptual Model to Assess Fuel Bed Moisture Content and Wind Velocity Effect on the Ignition Time and Probability
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Non-Destructive Fuel Volume Measurements Can Estimate Fine-Scale Biomass across Surface Fuel Types in a Frequently Burned Ecosystem

1
Tall Timbers Research Station, 13093 Henry Beadel Dr., Tallahassee, FL 32312, USA
2
Athens Fire Laboratory, Southern Research Station, USDA Forest Service, 320 Green Street, Athens, GA 30602, USA
3
Department of Forest and Rangeland Stewardship, Warner College of Natural Resources, Colorado State University, Fort Collins, CO 80538, USA
*
Author to whom correspondence should be addressed.
Submission received: 30 May 2021 / Revised: 2 July 2021 / Accepted: 9 July 2021 / Published: 14 July 2021
(This article belongs to the Special Issue Advances in the Measurement of Fuels and Fuel Properties)

Abstract

:
Measuring wildland fuels is at the core of fire science, but many established field methods are not useful for ecosystems characterized by complex surface vegetation. A recently developed sub-meter 3D method applied to southeastern U.S. longleaf pine (Pinus palustris) communities captures critical heterogeneity, but similar to any destructive sampling measurement, it relies on separate plots for calculating loading and consumption. In this study, we investigated how bulk density differed by 10-cm height increments among three dominant fuel types, tested predictions of consumption based on fuel type, height, and volume, and compared this with other field measurements. The bulk density changed with height for the herbaceous and woody litter fuels (p < 0.001), but live woody litter was consistent across heights (p > 0.05). Our models predicted mass well based on volume and height for herbaceous (RSE = 0.00911) and woody litter (RSE = 0.0123), while only volume was used for live woody (R2 = 0.44). These were used to estimate consumption based on our volume-mass predictions, linked pre- and post-fire plots by fuel type, and showed similar results for herbaceous and woody litter when compared to paired plots. This study illustrates an important non-destructive alternative to calculating mass and estimating fuel consumption across vertical volume distributions at fine scales.

1. Introduction

The pace of discovery in wildland fire science has accelerated in the past two decades with technologically advanced instrumentation for measuring fire behavior [1,2], modeling of fire behavior in conjunction with atmospheric dynamics [3,4,5], and measuring fine- to coarse-scale attributes of vegetation using various remote sensing technologies [6,7,8,9,10]. Despite these advancements, field vegetation and fuel sampling techniques have been generally stagnant since the 1970s and 1980s [11] and were mainly developed for dry western conifer/mixed-conifer forests where coarse woody fuels are a dominant fuel type [12]. These field sampling and monitoring techniques were adopted nationally [13,14] for wildfires of the western U.S. where coarse-scale estimates of fuels are sufficient for stand-level averages and relationships with wildfire intensity and consumption, as well as inputs for wildfire simulations of tree canopy fires [15,16]. They are less useful for mesic, more productive sites (e.g., southeastern pinelands, midwestern grasslands) where fine fuels in mixed surface fuelbeds (leaf litter, grasses, and shrubs) drive the behavior of frequent, low-intensity fires [17,18,19]. Because of the prevalence of frequent, low-intensity fires in southeastern U.S. pinelands, which are primarily propagated by fine surface fuels, understanding the spatial distribution of these fuels and their influence on fire behavior is imperative for advancing fire science relevant to prescribed fire management [20].
Historically, fuels were classified into ‘fuel models.’ These fuel models have grouped fuels into four categories—grass, brush, timber, and slash [21]. These categories relate to fire behavior differences primarily through coarse relationships with fuel loading and distribution [21]. Since the late 1970s, live and dead woody and herbaceous fuel loading has been calculated through equations that use constant bulk densities over a management unit [22] or estimated using ocular estimates (e.g., [14,23]). They assume a constant fuel bulk density regardless of fuel height, which results in a monotonic increase in fuel load with depth [22,24]. Hence, fuels have historically been viewed through a coarse lens, despite the importance of fine scale fuel variation to fire ecology [17,25,26]. New approaches are needed for better fine-scale estimates of mass, volume, and bulk density of various fuel types found in frequently burned surface fire regimes.
A new 3D fuel method developed by Hawley et al. [27] can quantify the variation in bulk density estimates on a sub-meter scale. Understanding how volume and mass change by fuel type at these finer scales may be an essential parameter in predicting fire behavior [17,19,28] and fire effects on floral diversity patterns [29,30].
Although heterogeneous bulk density can now be captured with the new 3D fuels methodology [27], this technique has the same limitation as many fire effects experiments that aim to measure fuel consumption—namely, it relies on destructive sampling where fuel is removed to measure fuel loading (biomass) and spatially separated paired plots are required to infer fuel consumed by the fire. To capture both pre-fire fuel loading and subsequent consumption by fire, some studies have collected large samples of pre- and post-burn data or attempted to pair the pre- and post-burn plots through their visual similarity and vegetation type [31].
Paired sampling generally works well for examining high intensity/high severity wildland fires where there is complete or near-complete consumption, but less so for frequent low-intensity prescribed fires where consumption is mainly limited to surface fuels. This results in unburned aerial fuels such as shrubs dominating post-burn biomass [31,32,33]. If mass can be accurately and precisely predicted at fine scales, we can better explore the effects of fuel structure and mass on fire behavior, and vice versa, in this heterogenous vegetation. If a strong relationship can be found between volume, mass, and height in pre-fire plots where destructive sampling occurred, then the mass can be predicted in non-destructive plots pre-fire and provide more accurate and precise measurements of consumption, especially by fuel type.
Southeastern pine ecosystems are a prime example of where the relationship between mass and volume at fine scales are particularly important [18,34]. These ecosystems are characterized by an overstory of pines, a sparse midstory, and an understory of complex surface vegetation consisting of shrubs, grasses, forbs, and leaf litter [25,35]. The structure and composition of this ecosystem is propagated by frequent, low-intensity fires (1–5-year return intervals) producing variable consumption of fine fuels, even within ‘complete’ (all black) burns [36]. Fire behavior and effects in relation to these surface fuels are difficult to predict because fuel mass, structure, consumption, and bulk density are interwoven at fine scales [19,37]. This creates a challenge to accurately measure or at least estimate them at the landscape level. Given the high spatial complexity of fuel types at the sub-meter scale, these systems require a more detailed perspective to evaluate properly, specifically when evaluating fuel characteristics, such as volume and mass by fuel type.
This study took an empirical approach to examine the relationships of fine-scale fuel attributes at a 1000 cm3 scale (10 cm × 10 cm × 10 cm) to better characterize bulk density and consumption estimates by fuel type in frequently burned ecosystems where grasses, leaf litter, and small shrubs dominate the fuels. The objectives of this study were to (1) investigate how bulk density varies with height among three dominant fine-scale fuel types, (2) test predictions of biomass based on fuel type, height, and voxelized volume estimations at the 10 cm3 scale, (3) use these predictions to estimate fuel consumption by linking pre- and post-burn data, and (4) compare consumption estimates with field measurements of consumption.

2. Materials and Methods

2.1. Site Description

Fuel measurements were collected from Pebble Hill Plantation (PHP), located in the Red Hills region of southern Georgia, USA (30°35′ N, 84°20′ W). The Red Hills is a temperate sub-tropical region experiencing annual mean precipitation of 1359 mm (recorded 21 km to the south at Tall Timbers Research Station, averaged between 1878–2010) and mean monthly temperatures ranging from 26.8 °C in July to 10.4 °C in January ([38], averaged between 1981–2010).
PHP is a 1222-ha plantation that has a history of timber and patch agriculture dating to the mid-1800s and is currently managed for hunting of northern bobwhite quail (Colinus virginianus L.). This management scheme allowed the succession of old agricultural fields to old-field pine-grasslands while maintaining frequent fire return intervals on portions of native groundcover [39]. In these pine-grassland communities, the overstory is dominated by longleaf pine (Pinus palustris Mill.) and a few shortleaf pine (Pinus echinata Mill.), averaging a stand density of 9.6 ± 6.3 m2/ha and basal area of 10.9 ± 6.3 m2/ha (Robertson and Ostertag, 2007). Meanwhile, the understory is a continuous matrix of grasses, forbs, and shrub hardwoods [39]. Understory species consist of wiregrass (Aristida stricta Michx.), bluestem (Andropogon spp.), Vaccinium spp., American beautyberry (Callicarpa americana L.), oaks (Quercus spp.), and hickory (Carya spp.).
Our clip plots were distributed amongst three 0.20-ha burn units at PHP. These burn units historically have been hand-burned every two years and were currently in a two-year rough. Collectively, 14 clip plots were non-randomly selected for pre-fire destructive sampling to best represent the fuel types in each burn unit: shrub, herbaceous, or surface fuels. This resulted in a stratified inventory of five shrub, five herbaceous, and four surface clip plots, all of which were centered on either a focal shrub, a wiregrass individual, or an open patch in the shrub-grass matrix lacking dominant shrub or grass clumps, respectively. Due to time constraints, there were only four clip plots selected for post-fire sampling—three shrub plots and one open patch plot. However, each of these was chosen as a paired plot to a pre-fire clip plot where they were selected based on how similar they were to a pre-fire plot regarding dominant fuel type and visual estimations of load and fuel distribution.

2.2. Sampling

To characterize three-dimensional, fine-scale variation in the clip plots, the voxel sampling approach found in Hawley et al., 2018 was used, which we briefly describe here. A rectangular, adjustable 3D sampling frame was used to collect fuel data up to 1 m in height at three different scales: entire clip plot (0.25 m3), single stratum (every 10 cm; 0.025 m3), and individual voxels (0.001 m3). Sampling was limited to below 1 m because shrubs and herbaceous material rarely grow above a meter in these frequently burned systems. The frame itself was 0.5 m × 0.5 m × 1 m and subdivided into ten 10 cm vertical intervals/strata. Each stratum contained twenty-five 1000 cm3 cells/voxels, totaling 250 voxels for the entire frame’s volume (Figure A1).
Using a top-down approach, sampling began at 100 cm, and the sliding square frame was lowered 10 cm at a time. Within each stratum and voxel, presence/absence was recorded for each fuel type. The biomass was then destructively harvested by clipping and bagging the material. After each stratum was clipped, the frame was lowered another 10 cm to the next height stratum, and the volume and biomass were collected again until the last stratum (0–10 cm) was reached. All biomass was collected in June of 2019.
The samples were sorted into the various fuel type categories indicated by the voxel data. Fuel types were then combined or eliminated into three fuel categories. The biomass samples were dried at 70 °C for 48 h, consistent with many protocols [28,31].
For the pre-fire clip plots, both the voxelized volume and biomass data were collected. However, only the volume data were collected pre-fire for post-fire clip plots, and then both residual volume and biomass were collected post-fire (Table A1).

2.3. Statistical Analyses

For the analyses, vegetation was consolidated into three primary fuel categories: herbaceous, woody litter, and live woody material. The herbaceous category included bunchgrass, wiregrass, forbs, and vines. Woody litter and live woody material primarily represented shrubs, although some overstory trees contributed to the litter category. Woody litter included non-oak and oak litter and leaves along with dead standing material. Woody live encompassed both non-oak and oak live material (living stems, twigs, and foliage).
To estimate total volume for each stratum’s fuel categories, the voxel presence/absence data were used. If the fuel category was present in a voxel, then that fuel category had a volume of 1000 cm3, or 0.001 m3. All 250 voxels in each clip plot were subjected to this volume calculation, and total volumes were estimated for each 10 cm height stratum. However, only strata that had both volume and biomass recorded were used in the analysis. As such, the smallest volume used was 1000 cm3 and the smallest biomass used was 0.01 g per stratum.
To determine if bulk density changes with height, a Kruskal–Wallis and pairwise Wilcoxon test was used for both the woody live and herbaceous fuel categories between four height increments (0–10, 10–20, 20–30, and 30–40 cm). A Mann–Whitney U test was conducted to examine if woody litter bulk density changes with height between two height increments (0–10 cm and 10–20 cm).
To investigate the relationship between volume and mass, a linear regression for the woody live fuel category was performed using the lm() function in the R stats package. Normality of the residuals was assessed using the Shapiro–Wilk test (p < 0.001) and transformed mass using the square root function to obtain normality (Shapiro–Wilk: p = 0.73). Following this transformation, a linear regression was calculated to predict mass based on voxelized volume alone. In this regression, height increments between 10–70 cm were used for the live woody fuel type to minimize residual error.
Despite a log transformation, assumptions of a linear regression could not be met for the herbaceous and woody litter categories. As such, exponential, nonlinear regressions were performed with height and volume as predictors of mass. The nls() function in the R stats package was used to fit the nonlinear models. Given that the majority (>95%) of herbaceous material occurred in height increments between 0–40 cm, only the data associated with these height increments were used in the regression, and heights between 0–20 cm were used for the woody litter fuel type. Prediction vs. actual plots were created using our regressions equations and linear regressions run to compare the predicted to the observed data. For all tests, significance was set at p < 0.05. For reference, we considered plot-level regressions for volume and mass, but found that the relationships were not significant, possibly due to the small sample size.
The linear and nonlinear regressions for each fuel type were used to calculate fuel loading in the post-fire plots using the voxelized volume data taken before the burns. Fuel consumption was calculated as the biomass collected following the fire subtracted from the fuel loading calculated pre-fire. To compare this method of calculating fuel loading and consumption to using paired plots, the biomass collected post-fire was subtracted from the biomass collected pre-fire to obtain fuel consumption.

3. Results

3.1. Live Woody

There were no significant differences in bulk density (H = 13.29, df = 9, p = 0.15; Table 1, Figure 1) between height increments. Therefore, the layer height was not used as a predictor in the linear regression.
A significant regression equation was found (F(1,53) = 42.911, p < 0.001), with an R2 of 0.44 (Figure 2). The estimates for the linear regression coefficients can be found in Table 2. The prediction vs. the actual plot showed a positive correlation between the predicted and observed data (F(1,63) = 39.27, p < 0.001, R2 = 0.37; Figure 3).
Using this equation, the loading was calculated for each plot, pre-fire, using only the voxelized volume (Figure 3). The median and interquartile range (IQR) fuel consumption was 7.95 ± 20.42 g (Table 3). For the paired plots, the median (±IQR) fuel consumption was 13.47 ± 10.52 g (Table 3).

3.2. Herbaceous

There were significant differences in bulk density (H = 51.05, df = 9, p < 0.001; Table 1). Therefore, the height was used as a predictor in the nonlinear regression.
An exponential regression equation was used to predict the mass based on the volume and height (residual standard error (RSE) = 0.00911; Figure 4). The estimates for the nonlinear regression coefficients can be found in Table 2. The prediction vs. the actual plot showed a positive correlation between the predicted and observed data (F(1,46) = 142.5, p < 0.001, R2 = 0.75; Figure 3).

3.3. Woody Litter

There were significant differences in bulk density (W= 88.05, p = 0.0011; Table 1) between two height increments (0–10 cm and 10–20 cm). Therefore, the height was used as a predictor in the nonlinear regression.
An exponential regression equation was used to predict the mass based on the volume and height (RSE = 0.01229; Figure 5). The estimates for the nonlinear regression coefficients can be found in Table 2. The prediction vs. the actual plot showed a positive correlation between the predicted and observed data (F(1,18) = 72.57, p < 0.001, R2 = 0.79; Figure 3).

4. Discussion

This study illustrates an effective way to calculate biomass across vertical volume distributions and fuel types at the scales required to characterize complex fuelbeds common in low-intensity fires that shape many frequently burned ecosystems. There were distinct volume-to-mass relationships among these three common fuel types—live woody material, herbaceous material, and woody litter—that have, in the past, mainly been represented as average stand-level mass and bulk density values [31]. These results indicate that the height distribution of mass was significant for the herbaceous and woody litter fuel types, but not for live woody material (Table 1). This vertical evenness of bulk density for live woody material is consistent with previous work characterizing shrubs of similar (<1 m) stature [22]. However, the bulk density of herbaceous fuel varied, particularly in the 0–30 cm height range.
Wiregrass, the dominant herbaceous component in this ecosystem, has a dense crown closer to the forest floor and accumulates senesced material around the crown [40,41,42]. Given that these plots had two years of growth since the last fire and a long history of frequent fire (40 years) [39], our results corroborated that the crown was dense enough to have a different bulk density than the upper portions of the plant [42]. As such, applying a height metric for herbaceous fuel estimates is required to accurately represent the vertical distribution of a major component of the fuelbed.
While woody litter was present in multiple strata, most of the mass (>99%) was found in the first two strata (0–10 cm and 10–20 cm). In longleaf pine ecosystems, leaf litter in general often becomes suspended in wiregrass and shrubs [43]. It increases the vertical heterogeneity of the fuel bed [17] while also influencing fire behavior [19]. We showed that this suspended litter is less compact (1.35 kg/m3 in the 0–10 cm layer vs. 0.38 kg/m3 in the 10–20 cm layer), and in combination with the fact that it dries out quicker than the litter layer found near mineral soil, this vertical variability within the herbaceous fuels is important to consider in fuelbed dynamics [37]. These distinctions of mass distribution between and within fuel types contribute to the heterogeneity of fine-scale fuels found in these ecosystems, which have not been examined in this detail before.
These fine-scale bulk density estimations could provide a common link between ecosystems with similar fuel components. For instance, the structure and size of mature wiregrass (bunchgrass) tussocks are similar among southern pine ecosystems when present. Still, their growth rates, particularly after a fire, and flowering are partially dependent on regional climate and soil characteristics, at the site or stand level, by history of land use, fire, and soil disturbance, and continuously by competition with the overstory and midstory [44]. However, the bulk density of these mature individuals at the 1000 cm3 scale is likely very similar among these sites and could be represented using these equations.
This study provides predictions on how biomass varies with fuel type, the volume occupied, and the height within the surface fuel layer, which can be used in fire behavior and fire effects studies that evaluate change in plant structure, mortality, reproduction, and composition patterns as well as fuel consumption at the same fine scale. In particular, when used in conjunction with fire, it is desirable to follow a plot from pre-fire levels of mass and vegetation composition to post-fire values. However, as pre-fire mass and fuel consumption have been notoriously difficult to measure directly [7,14,45], we developed a robust approach where volume and fuel type can be measured beforehand without destructive sampling and then link that to paired pre-fire plots of similar fuel types that were clipped, dried, and weighed. However, these results may only be paramount in respect to ecosystems that are depend on low-intensity, frequent surface fires.
Fuel consumption was then calculated by estimating pre-fire biomass with occupied volume using our linear and nonlinear regressions. Although a vastly different methodology from traditional methods, they both resulted in similar average fuel consumption for all but live woody material (Table 3). For the live woody material, one of the shrub plots did not burn well (Figure 6) and had an abnormally large amount of live biomass pre-fire (compared to the other shrub plots), resulting in an underestimation of mass. As noted earlier, this patchiness is common in these low-intensity fires where variability in consumption creates different sizes of shrubs within and across stands. A larger sample size with more varying shrubs sizes could provide more robust comparisons of average live woody consumption to the paired plots. Although our regressions were significant, a larger sample size could enhance the accuracy of the regressions and strength of the mass predictions. Future studies could expand mass and volume ranges across these and other fuel types, and in other frequently burned systems to increase their applicability. In the end, these regressions could be used to estimate biomass pre-fire more accurately and precisely without requiring destructive sampling, particularly in frequently burned southeastern U.S. pinelands.
Volume in our sampling design is generalized down to the 1000 cm3 or 0.001 m3 scale. This is a substantial improvement considering that historically in order to estimate fuel volume, individual plants were represented as spheres and cylinders [46]. These oversimplified shapes greatly overestimate the actual volume [18], and by extension, greatly underestimate the bulk density. Furthermore, our method was likely the smallest realistic volume that can be measured by hand in the field. These fine-scale volume estimations are currently the best field method to categorize these fine, heterogeneous fuels.
One can obtain similar or even finer scale volumetric data from more precise methods, such as terrestrial-laser scanning (TLS), and pair these with our biomass collections. While TLS can provide the continuous fine-scale 3D structural data across a larger area [47], 3D manual sampling is still required to differentiate between interwoven fuel types and measure certain fuel aspects. These include fuel type distribution, mass, ground fuels such as compacted leaf litter and partially decomposed organic material [45]. In addition, the fine-scale volume from TLS has been successfully linked to laboratory and field measurements of biomass and leaf area [7,8,18]. Anecdotally, the difficulty with linking the two lies with achieving precise co-location and error associated with vegetation change or movement between data acquisition of each method caused by wind, fuel moisture, solar heating, and response to clipping as you move down the sampling frame. Additionally, TLS requires technology that may not be readily available and requires involved training, expertise, and processing skills. In comparison, the 3D fuels sampling protocol is inexpensive, follows similar presence/absence sampling protocols as other fuels methods, is adaptable across ecosystems, and accurately captures the fine-scale distribution of fuels, particularly biomass. In the end, this is the first known study to predict fine-scale fuel consumption of interwoven fuel types.
Previously, fine-scale homogeneity has been assumed because fuel load and fuel characterization methods were developed with coarse scale landscape processes in mind [16]. This study’s 3D fuels methodology [27] used in recent studies [8,34] reveals the heterogeneity of the very same surface fuels that drive surface fire behavior and fire effects at the same scale [2,17,19,29]. These fine-scale studies have implications at broader scales by representing fine-scale bulk density and consumption estimates across a stand based on the known distribution of fuel types rather than average values.

5. Conclusions

This study is the first to evaluate bulk density estimations by only using field-based methods at such a fine scale. The predictions of mass across 10-cm height increments of fuel types illustrate the complex vertical heterogeneity in bulk density that varies at these fine scales. The results of this study could increase the accuracy of pre-fire biomass and fuel consumption estimates and reduce the need for destructive approaches of pre- and post-fire plot pairing of “similar” fuel types. Investigating bulk density, the interaction between volume, biomass, and height, is imperative to predicting fine-scale fuel consumption that can have implications for stand and landscape-level characterization of fuels and predictions of fire behavior and fire effects. These kinds of measurements will also be critical for refining inputs for coupled fire-atmosphere fire behavior models [3,4,15].

Author Contributions

This study was conceived and designed by E.L.L., C.M.H. (Christie M. Hawley), C.M.H. (Chad M. Hoffman), J.K.H., S.P. and J.J.O. The experiment was established by E.L.L. and C.M.H. (Christie M. Hawley). Field data collected by C.M.H. (Christie M. Hawley), Q.A.H. and E.L.L., and lab data was processed by C.M.H. (Christie M. Hawley) and Q.A.H. Q.A.H. conducted all statistical analyses, and Q.A.H. and E.L.L. wrote significant portions of the paper. All authors provided critical input and feedback on the research, analyses, and manuscript. All authors have read and agreed to the published version of the manuscript.

Funding

Strategic Environmental Research and Development Program RC19-1119.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

The data presented in this study are available in the Appendix A, Table A1.

Acknowledgments

Thanks to Pebble Hill Plantation, Tall Timbers Fire Ecology Program, and Kevin Robertson, whose long-term study site was made available for this work. We thank several for field and laboratory technical support, including D. Wallace, L. Stiles, N. Spencer, M. Johnson, M. Nolasco, and A. Wilson from Tall Timbers Research Station as well as C. Beasley, A. Coates, and A. McClure from Virginia Polytechnic Institute and State University. We acknowledge the USDA Forest Service, Southern Research Station, the Center for Forest Disturbance Science and the Athens Fire Lab, Athens, GA, for their support.

Conflicts of Interest

The authors declare that there is no conflict of interest.

Appendix A

Figure A1. Example of data sheet used to collect voxel data for fuel types. Wiregrass/Bunchgrass, Other Graminoids, Forbs, and Vines were aggregated into the herbaceous fuel category. Woody Species (Leaves/Litter) represented the woody litter category. Woody Species (Live) represented the live woody category.
Figure A1. Example of data sheet used to collect voxel data for fuel types. Wiregrass/Bunchgrass, Other Graminoids, Forbs, and Vines were aggregated into the herbaceous fuel category. Woody Species (Leaves/Litter) represented the woody litter category. Woody Species (Live) represented the live woody category.
Fire 04 00036 g0a1
Table A1. Data used in this study. Burn Number represents which arbitrary burn unit was sampled while Plot represents an individual clip plot in each burn unit. The “Pre” preceding the plot number indicates a Preburn plot while “Post” preceding the plot number represents a Postburn plot. The number in Plot represents paired plots. For example, within the same Burn Number, Pre2 and Post2 are paired plots. Burn Status describes when the data was taken, where Pre = before burn and Post = after burn. Therefore, Mass and Volume were collected before the burn for every preburn plot. While mass was only recorded after the burn for postburn plots, volume was recorded both before and after the burn. Height describes at which height stratum the data was collected. For Mass and Volume, H = Herbaceous, LW = Live Woody, and WL = Woody Litter. Further descriptions of the methodology are in the main text.
Table A1. Data used in this study. Burn Number represents which arbitrary burn unit was sampled while Plot represents an individual clip plot in each burn unit. The “Pre” preceding the plot number indicates a Preburn plot while “Post” preceding the plot number represents a Postburn plot. The number in Plot represents paired plots. For example, within the same Burn Number, Pre2 and Post2 are paired plots. Burn Status describes when the data was taken, where Pre = before burn and Post = after burn. Therefore, Mass and Volume were collected before the burn for every preburn plot. While mass was only recorded after the burn for postburn plots, volume was recorded both before and after the burn. Height describes at which height stratum the data was collected. For Mass and Volume, H = Herbaceous, LW = Live Woody, and WL = Woody Litter. Further descriptions of the methodology are in the main text.
Burn NumberPlotBurn StatusHeightH Mass (g)H Volume (m3)LW Mass (g)LW Volume (m3)WL Mass (g)WL Volume (m3)
1Pre1Pre0–1018.70.0257.450.01236.930.022
1Pre1Pre10–204.920.02415.640.0160.070.007
1Pre1Pre20–302.380.02121.280.01200.003
1Pre1Pre30–401.090.01218.410.01100
1Pre1Pre40–500.320.0124.770.01800
1Pre1Pre50–600.080.00317.180.01500
1Pre1Pre60–70009.130.00600
1Pre1Pre70–800014.550.00800
1Pre1Pre80–90005.820.00800
1Pre1Pre90–1000017.030.01400
1Pre2Pre0–1067.070.02512.410.00619.530.018
1Pre2Pre10–206.280.0257.660.0132.590.007
1Pre2Pre20–301.450.0181.450.00900
1Pre2Pre30–400.230.0120000
1Pre2Pre40–50000000
1Pre2Pre50–60000000
1Pre2Pre60–70000000
1Pre2Pre70–80000000
1Pre2Pre80–90000000
1Pre2Pre90–100000000
1Pre3Pre0–1061.680.0256.290.00127.330.02
1Pre3Pre10–2026.240.02510.490.0050.610
1Pre3Pre20–306.790.02411.080.01100
1Pre3Pre30–402.190.0195.010.01100
1Pre3Pre40–501.130.0198.570.0080.230.002
1Pre3Pre50–600.250.0075.370.0100.002
1Pre3Pre60–700.090.0036.90.0100
1Pre3Pre70–80000.930.00500
1Pre3Pre80–90000000
1Pre3Pre90–100000000
1Pre4Pre0–1034.640.0258.380.00823.130.02
1Pre4Pre10–2017.730.0255.180.0090.120.001
1Pre4Pre20–3016.730.0257.890.01200
1Pre4Pre30–4013.550.0259.180.01600
1Pre4Pre40–508.880.02516.270.0200
1Pre4Pre50–603.560.02511.410.01400
1Pre4Pre60–700.460.0172.440.0100
1Pre4Pre70–80000000
1Pre4Pre80–90000000
1Pre4Pre90–100000000
1Pre5Pre0–1063.530.02510.680.0127.260.025
1Pre5Pre10–2010.10.0258.450.020.780.002
1Pre5Pre20–302.180.0248.530.01600
1Pre5Pre30–400.550.0071.350.00800
1Pre5Pre40–503.270.0080000
1Pre5Pre50–600.010.0030000
1Pre5Pre60–70000000
1Pre5Pre70–80000000
1Pre5Pre80–90000000
1Pre5Pre90–100000000
1Pre6Pre0–1045.930.0256.460.00112.380.012
1Pre6Pre10–2012.830.0256.410.0055.130.015
1Pre6Pre20–303.670.02510.80.01500
1Pre6Pre30–400.790.0148.130.00900
1Pre6Pre40–500.290.018.640.00900
1Pre6Pre50–600.050.0018.330.01400
1Pre6Pre60–70000.940.00200
1Pre6Pre70–80000000
1Pre6Pre80–90000000
1Pre6Pre90–100000000
3Pre1Pre0–1051.090.0250.640.0020.530.001
3Pre1Pre10–2024.850.0250.790.00300
3Pre1Pre20–3014.430.02500.00100
3Pre1Pre30–401.340.0240000
3Pre1Pre40–500.170.0150000
3Pre1Pre50–60000000
3Pre1Pre60–70000000
3Pre1Pre70–80000000
3Pre1Pre80–90000000
3Pre1Pre90–100000000
3Pre2Pre0–1043.360.0258.730.00985.730.025
3Pre2Pre10–2010.20.02411.220.0112.490.005
3Pre2Pre20–304.310.02214.650.0160.340.002
3Pre2Pre30–401.570.0189.780.0100
3Pre2Pre40–500.870.018.50.01100
3Pre2Pre50–602.090.00711.250.02100
3Pre2Pre60–701.680.0047.320.01500
3Pre2Pre70–800.750.0045.450.01300
3Pre2Pre80–902.680.0046.430.01200
3Pre2Pre90–1003.180.0087.580.01400
3Pre3Pre0–1027.420.02327.550.00471.390.025
3Pre3Pre10–208.440.0189.20.00310.270.007
3Pre3Pre20–303.820.0153.130.00700
3Pre3Pre30–401.150.0082.130.00200
3Pre3Pre40–500.380.0040000
3Pre3Pre50–60000000
3Pre3Pre60–70000000
3Pre3Pre70–80000000
3Pre3Pre80–90000000
3Pre3Pre90–100000000
3Pre4Pre0–1021.030.0256.010.00657.740.025
3Pre4Pre10–205.710.02511.550.0120.60.001
3Pre4Pre20–303.130.0228.780.00500
3Pre4Pre30–400.740.01214.090.01700
3Pre4Pre40–500.220.00513.820.02500
3Pre4Pre50–600.20.00215.350.02300
3Pre4Pre60–700.080.00215.90.02400
3Pre4Pre70–800.070.00112.790.02400
3Pre4Pre80–90003.790.01400
3Pre4Pre90–100001.970.00700
3Pre5Pre0–1011.710.02400.00256.430.025
3Pre5Pre10–208.980.0244.370.00300
3Pre5Pre20–301.130.0124.660.00500
3Pre5Pre30–400.820.00910.670.0200
3Pre5Pre40–500.440.00810.140.01600
3Pre5Pre50–600.320.0068.980.01800
3Pre5Pre60–700.20.0058.640.01400
3Pre5Pre70–80000000
3Pre5Pre80–90000000
3Pre5Pre90–100000000
3Pre6Pre0–1016.140.02313.070.01433.30.025
3Pre6Pre10–203.050.02211.430.01700.001
3Pre6Pre20–301.020.01414.290.0170.150
3Pre6Pre30–400.650.00723.20.02500
3Pre6Pre40–500.640.00913.110.02300
3Pre6Pre50–6000.0050000
3Pre6Pre60–700.060.0040000
3Pre6Pre70–80000000
3Pre6Pre80–90000000
3Pre6Pre90–100000000
1Post1Post0–101.010.00922.520.0048.130.011
1Post1Post10–200.190.00217.780.00400
1Post1Post20–300016.860.00900
1Post1Post30–400020.090.01900
1Post1Post40–500016.790.01400
1Post1Post50–600018.850.01100
1Post1Post60–700011.530.00600
1Post1Post70–80009.60.00800
1Post1Post80–900018.380.0100
1Post1Post90–1000026.430.02300
1Post2Post0–100.910.0092.310.0032.230
1Post2Post10–200.170.0014.760.00300
1Post2Post20–300.020.0026.240.00600
1Post2Post30–40002.330.00300
1Post2Post40–50000000
1Post2Post50–60000000
1Post2Post60–70000000
1Post2Post70–80000000
1Post2Post80–90000000
1Post2Post90–100000000
1Post3Post0–105.240.0222.390.0036.170.025
1Post3Post10–201.810.0082.990.00400
1Post3Post20–300.80.0062.390.00300
1Post3Post30–400.260.0025.850.00600
1Post3Post40–500016.150.01300
1Post3Post50–60004.130.00900
1Post3Post60–70003.380.00700
1Post3Post70–80000000
1Post3Post80–90000000
1Post3Post90–100000000
1Post6Post0–100.760.0135.280.0041.190.004
1Post6Post10–2000.0085.440.00300
1Post6Post20–30002.250.00100
1Post6Post30–40002.860.00200
1Post6Post40–50002.460.00600
1Post6Post50–60000.990.00500
1Post6Post60–70000000
1Post6Post70–80000000
1Post6Post80–90000000
1Post6Post90–100000000
1Post1Pre0–10NA0.025NA0.016NA0.022
1Post1Pre10–20NA0.023NA0.022NA0
1Post1Pre20–30NA0.011NA0.014NA0
1Post1Pre30–40NA0.002NA0.014NA0
1Post1Pre40–50NA0NA0.014NA0
1Post1Pre50–60NA0NA0.013NA0
1Post1Pre60–70NA0NA0.009NA0
1Post1Pre70–80NA0NA0.009NA0
1Post1Pre80–90NA0NA0.007NA0
1Post1Pre90–100NA0NA0.019NA0
1Post2Pre0–10NA0.025NA0.002NA0.017
1Post2Pre10–20NA0.024NA0.007NA0.005
1Post2Pre20–30NA0.024NA0.008NA0.001
1Post2Pre30–40NA0.02NA0.007NA0
1Post2Pre40–50NA0.009NA0.001NA0
1Post2Pre50–60NA0.001NA0.002NA0
1Post2Pre60–70NA0NA0NA0
1Post2Pre70–80NA0NA0NA0
1Post2Pre80–90NA0NA0NA0
1Post2Pre90–100NA0NA0NA0
1Post3Pre0–10NA0.025NA0.003NA0.008
1Post3Pre10–20NA0.025NA0.003NA0.007
1Post3Pre20–30NA0.024NA0.001NA0.004
1Post3Pre30–40NA0.012NA0.008NA0.004
1Post3Pre40–50NA0.006NA0.007NA0.001
1Post3Pre50–60NA0NA0.01NA0
1Post3Pre60–70NA0NA0.006NA0
1Post3Pre70–80NA0NA0NA0
1Post3Pre80–90NA0NA0NA0
1Post3Pre90–100NA0NA0NA0
1Post6Pre0–10NA0.025NA0.001NA0.021
1Post6Pre10–20NA0.025NA0.001NA0.008
1Post6Pre20–30NA0.024NA0.003NA0.001
1Post6Pre30–40NA0.023NA0.007NA0
1Post6Pre40–50NA0.014NA0.022NA0
1Post6Pre50–60NA0.005NA0.019NA0
1Post6Pre60–70NA0.001NA0.005NA0
1Post6Pre70–80NA0NA0NA0
1Post6Pre80–90NA0NA0NA0
1Post6Pre90–100NA0NA0NA0

References

  1. Butler, B.; Teske, C.; Jimenez, D.; O’Brien, J.; Sopko, P.; Wold, C.; Vosburgh, M.; Hornsby, B.; Loudermilk, E.L. Observations of energy transport and rate of spreads from low intensity fires in longleaf pine habitat-RxCADRE 2012. Int. J. Wildland Fire 2016, 25, 76–89. [Google Scholar] [CrossRef] [Green Version]
  2. O’Brien, J.J.; Loudermilk, E.L.; Hornsby, B.; Hudak, A.T.; Bright, B.C.; Dickinson, M.B.; Hiers, J.K.; Teske, C.; Ottmar, R.D. High-resolution infrared thermography for capturing wildland fire behaviour: RxCADRE 2012. Int. J. Wildland Fire 2016, 25, 62–75. [Google Scholar] [CrossRef]
  3. Linn, R.; Reisner, J.; Colman, J.J.; Winterkamp, J. Studying wildfire behavior using FIRETEC. Int. J. Wildland Fire 2002, 11, 233–246. [Google Scholar] [CrossRef]
  4. Linn, R.R.; Goodrick, S.; Brambilla, S.; Brown, M.J.; Middleton, R.S.; O’Brien, J.J.; Hiers, J.K. QUIC-fire: A fast-running simulation tool for prescribed fire planning. Environ. Model. Softw. 2020, 125, 104616. [Google Scholar] [CrossRef]
  5. Mell, W.; Charney, J.; Jenkins, M.A.; Cheney, P.; Gould, J. Numerical simulations of grassland fire behavior from the LANL-FIRETEC and NIST-WFDS models. In Remote Sensing and Modeling Applications to Wildland Fires; Qu, J.J., Sommers, W.T., Yang, R., Riebau, A.R., Eds.; Springer: Berlin/Heidelberg, Germany, 2013; pp. 209–225. [Google Scholar] [CrossRef]
  6. Hudak, A.T.; Dickinson, M.B.; Bright, B.C.; Kremens, R.L.; Loudermilk, E.L.; O’Brien, J.J.; Hornsby, B.S.; Ottmar, R.D. Measurements relating fire radiative energy density and surface fuel consumption—RxCADRE 2011 and 2012. Int. J. Wildland Fire 2016, 25, 25–37. [Google Scholar] [CrossRef] [Green Version]
  7. Hudak, A.T.; Kato, A.; Bright, B.C.; Loudermilk, E.L.; Hawley, C.; Restaino, J.C.; Ottmar, R.D.; Prata, G.A.; Cabo, C.; Prichard, S.J. Towards spatially explicit quantification of pre and postfire fuels and fuel consumption from traditional and point cloud measurements. For. Sci. 2020, 66, 428–442. [Google Scholar] [CrossRef]
  8. Rowell, E.M.; Seielstad, C.A.; Ottmar, R.D. Development and validation of fuel height models for terrestrial lidar—RxCADRE 2012. Int. J. Wildland Fire 2016, 25, 38–47. [Google Scholar] [CrossRef]
  9. Zajkowski, T.J.; Dickinson, M.B.; Hiers, J.K.; Holley, W.; Williams, B.W.; Paxton, A.; Martinez, O.; Walker, G.W. Evaluation and use of remotely piloted aircraft systems for operations and research–RxCADRE 2012. Int. J. Wildland Fire 2016, 25, 114–128. [Google Scholar] [CrossRef]
  10. Chuvieco, E.; Aguado, I.; Salas, J.; García, M.; Yebra, M.; Oliva, P. Satellite remote sensing contributions to wildland fire science and management. Curr. For. Rep. 2020, 6, 81–96. [Google Scholar] [CrossRef]
  11. Brown, J.K.; Oberheu, R.D.; Johnston, C.M. Handbook for Inventorying Surface Fuels and Biomass in the Interior West; Gen. Tech. Rep. INT-129; U.S. Department of Agriculture, Forest Service, Intermountain Forest and Range Experimental Station: Ogden, UT, USA, 1982; p. 48. [Google Scholar] [CrossRef] [Green Version]
  12. Brown, J.K. Handbook for Inventorying Downed Woody Material; Gen. Tech. Rep. INT-16; U.S. Department of Agriculture, Forest Service, Intermountain Forest and Range Experimental Station: Ogden, UT, USA, 1974; p. 24. [Google Scholar]
  13. Ottmar, R.D.; Sandberg, D.V.; Riccardi, C.L.; Prichard, S.J. An overview of the Fuel Characteristic Classification System-Quantifying, classifying, and creating fuelbeds for resource planning. Can. J. For. Res. 2007, 37, 2383–2393. [Google Scholar] [CrossRef]
  14. Keane, R.E.; Dickinson, L.J. Development and Evaluation of the Photoload Sampling Technique; Research Paper RMRS-RP-61; U.S. Department of Agriculture, Forest Service, Rocky Mountain Research Station: Fort Collins, CO, USA, 2007; p. 29. [Google Scholar] [CrossRef]
  15. Linn, R.R.; Cunningham, P. Numerical simulations of grass fires using a coupled atmosphere—Fire model: Basic fire behavior and dependence on wind speed. J. Geophys. Res. 2005, 110, D13107. [Google Scholar] [CrossRef]
  16. Parsons, R.A.; Mell, W.E.; McCauley, P. Linking 3D spatial models of fuels and fire: Effects of spatial heterogeneity on fire behavior. Ecol. Model. 2011, 222, 679–691. [Google Scholar] [CrossRef]
  17. Hiers, J.K.; O’Brien, J.J.; Mitchell, R.J.; Grego, J.M.; Loudermilk, E.L. The wildland fuel cell concept: An approach to characterize fine-scale variation in fuels and fire in frequently burned longleaf pine forests. Int. J. Wildland Fire 2009, 18, 315–325. [Google Scholar] [CrossRef]
  18. Loudermilk, E.L.; Hiers, J.K.; O’Brien, J.J.; Mitchell, R.J.; Singhania, A.; Fernandez, J.C.; Cropper, W.P.; Slatton, K.C. Ground-based LIDAR: A novel approach to quantify fine-scale fuelbed characteristics. Int. J. Wildland Fire 2009, 18, 676–685. [Google Scholar] [CrossRef] [Green Version]
  19. Loudermilk, E.L.; O’Brien, J.J.; Mitchell, R.J.; Cropper, W.P.; Hiers, J.K.; Grunwald, S.; Grego, J.; Fernandez-Diaz, J.C. Linking complex forest fuel structure and fire behavior at fine scales. Int. J. Wildland Fire 2012, 21, 882–893. [Google Scholar] [CrossRef]
  20. Hiers, J.K.; O’Brien, J.J.; Varner, J.M.; Butler, B.W.; Dickinson, M.; Furman, J.; Gallagher, M.; Godwin, D.; Goodrick, S.L.; Hood, S.M.; et al. Prescribed fire science: The case for a refined research agenda. Fire Ecol. 2020, 16, 11. [Google Scholar] [CrossRef] [Green Version]
  21. Anderson, H.E. Aids to Determining Fuel Models for Estimating Fire Behavior; Gen. Tech. Rep. INT-122; U.S. Department of Agriculture, Forest Service, Intermountain Forest and Range Experiment Station: Ogden, UT, USA, 1982; p. 22. [Google Scholar] [CrossRef] [Green Version]
  22. Snell, J.A. Direct Estimation of Surface Fuel Bulk Density and Loading in Western Montana and Northern Idaho. Master’s Thesis, University of Montana, Missoula, MT, USA, 1979. [Google Scholar]
  23. Vihnanek, R.E.; Balog, C.S.; Wright, C.S.; Ottmar, R.D.; Kelly, J.W. Stereo photo series for quantifying natural fuels. In Post-Hurricane Fuels in Forests of the Southeast United States; Gen. Tech. Rep. PNW-GTR-803; U.S. Department of Agriculture, Forest Service, Pacific Northwest Research Station: Portland, OR, USA, 2009; Volume XII, p. 53. [Google Scholar] [CrossRef]
  24. Albini, F.A.; Brown, J.K. Predicting Slash Depth for Fire Modeling; Res. Pap. INT-RP-206; USDA Forest Service, Intermountain Forest and Range Experiment Station: Ogden, UT, USA, 1978; p. 22. [Google Scholar]
  25. Mitchell, R.J.; Hiers, J.K.; O’Brien, J.; Starr, G. Ecological Forestry in the Southeast: Understanding the Ecology of Fuels. J. For. 2009, 107, 391–397. [Google Scholar]
  26. Ritter, S.M.; Hoffman, C.M.; Battaglia, M.A.; Stevens-Rumann, C.S.; Mell, W.E. Fine-scale fire patterns mediate forest structure in frequent-fire ecosystems. Ecosphere 2020, 11, e03177. [Google Scholar] [CrossRef]
  27. Hawley, C.M.; Loudermilk, E.L.; Rowell, E.M.; Pokswinski, S. A novel approach to fuel biomass sampling for 3D fuel characterization. MethodsX 2018, 5, 1597–1604. [Google Scholar] [CrossRef]
  28. Brown, J.K. Bulk densities of nonuniform surface fuels and their application to fire modeling. For. Sci. 1981, 27, 667–683. [Google Scholar] [CrossRef]
  29. Wiggers, M.S.; Kirkman, L.K.; Boyd, R.S.; Hiers, J.K. Fine-scale variation in surface fire environment and legume germination in the longleaf pine ecosystem. For. Ecol. Manag. 2013, 310, 54–63. [Google Scholar] [CrossRef]
  30. Loudermilk, E.L.; Dyer, L.; Pokswinski, S.; Hudak, A.T.; Hornsby, B.; Richards, L.; Dell, J.; Goodrick, S.L.; Hiers, J.K.; O’Brien, J.J. Simulating Groundcover Community Assembly in a Frequently Burned Ecosystem Using a Simple Neutral Model. Front. Plant Sci. 2019, 10, 1107. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  31. Ottmar, R.D.; Hudak, A.T.; Prichard, S.J.; Wright, C.S.; Restaino, J.C.; Kennedy, M.C.; Vihnanek, R.E. Pre-fire and post-fire surface fuel and cover measurements collected in the south-eastern United States for model evaluation and development—RxCADRE 2008, 2011 and 2012. Int. J. Wildland Fire 2016, 25, 10–24. [Google Scholar] [CrossRef]
  32. Peterson, J.L. Analysis and Reduction of the Errors of Predicting Prescribed Burn Emissions. Master’s Thesis, University of Washington, Seattle, WA, USA, 1987. [Google Scholar]
  33. Ottmar, R.D. Wildland fire emissions, carbon, and climate: Modeling fuel consumption. For. Ecol. Manag. 2013, 317, 41–50. [Google Scholar] [CrossRef]
  34. Rowell, E.; Loudermilk, E.L.; Hawley, C.; Pokswinski, S.; Seielstad, C.; Queen, L.; O’brien, J.J.; Hudak, A.T.; Goodrick, S.; Hiers, J.K. Coupling terrestrial laser scanning with 3D fuel biomass sampling for advancing wildland fuels characterization. For. Ecol. Management. 2020, 462, 117945. [Google Scholar] [CrossRef]
  35. Glitzenstein, J.S.; Streng, D.R.; Wade, D.D. Fire frequency effects on longleaf pine (Pinus palustris P. Miller) vegetation in South Carolina and Northeast Florida, USA. Nat. Areas J. 2003, 23, 22–37. [Google Scholar]
  36. Reid, A.M.; Robertson, K.M.; Hmielowski, T.L. Predicting litter and live herb fuel consumption during prescribed fires in native and old-field upland pine communities of the southeastern United States. Can. J. For. Res. 2012, 42, 1611–1622. [Google Scholar] [CrossRef]
  37. Nelson, R.M.; Hiers, J.K. The influence of fuelbed properties on moisture drying rates and timelags of longleaf pine litter. Can. J. For. Res. 2008, 38, 2394–2404. [Google Scholar] [CrossRef]
  38. Arguez, A.; Durre, I.; Applequist, S.; Squires, M.; Vose, R.; Yin, X.; Bilotta, R. NOAA US Climate Normals (1981–2010); NOAA National Centers for Environmental Information, U.S. Department of Commerce: Asheville, NC, USA, 2010. [Google Scholar] [CrossRef]
  39. Robertson, K.M.; Ostertag, T.E. Effects of land use on fuel characteristics and fire behavior in pinelands of Southwest Georgia. In Proceedings of the 23rd Tall Timbers Fire Ecology Conference: Fire in Grassland and Shrubland Ecosystems; Masters, R.E., Galley, K.E.M., Eds.; Tall Timbers Research Station: Tallahassee, FL, USA, 2007; pp. 181–191. [Google Scholar]
  40. Wright, H.A. Why squirreltail is more tolerant to burning than needle-and-thread. J. Range Manag. 1971, 24, 277–284. [Google Scholar] [CrossRef]
  41. Engle, D.M.; Mitchell, R.L.; Stevens, R.L. Late growing-season fire effects in mid-successional tallgrass prairies. J. Range Manag. 1998, 51, 115–121. [Google Scholar] [CrossRef]
  42. Shearman, T.M.; Varner, J.M.; Robertson, K.; Hiers, J.K. Allometry of the pyrophytic Aristida in fire—Maintained longleaf pine—Wiregrass ecosystems. Am. J. Bot. 2019, 106, 18–28. [Google Scholar] [CrossRef] [PubMed]
  43. Hendricks, J.J.; Wilson, C.A.; Boring, L.R. Foliar litter position and decomposition in a fire-maintained longleaf pine—Wiregrass ecosystem. Can. J. For. Res. 2002, 32, 928–941. [Google Scholar] [CrossRef]
  44. Mulligan, M.K.; Kirkman, L.K.; Mitchell, R.J. Aristida beyrichiana (wiregrass) establishment and recruitment: Implications for restoration. Restor. Ecol. 2002, 10, 68–76. [Google Scholar] [CrossRef]
  45. Skowronski, N.S.; Gallagher, M.R. Fuels Characterization Techniques. In Encyclopedia of Wildfires and Wildland-Urban Interface (WUI) Fires; Manzello, S.L., Ed.; Springer International Publishing: Cham, Switzerland, 2018; pp. 1–10. [Google Scholar] [CrossRef]
  46. Van Wagner, C.E. The line intersect method in forest fuel sampling. For. Sci. 1968, 14, 20–26. [Google Scholar] [CrossRef]
  47. Calders, K.; Adams, J.; Armston, J.; Bartholomeus, H.; Bauwens, S.; Bentley, L.P.; Chave, J.; Danson, F.M.; Demol, M.; Disney, M. Terrestrial laser scanning in forest ecology: Expanding the horizon. Remote Sens. Environ. 2020, 251, 112102. [Google Scholar] [CrossRef]
Figure 1. Bulk density values for all fuel types from stratum 0 to 100 cm, in 10 cm increments.
Figure 1. Bulk density values for all fuel types from stratum 0 to 100 cm, in 10 cm increments.
Fire 04 00036 g001
Figure 2. Regression for live woody fuel material with volume as a predictor of mass (mass has been backtransformed from square root). The equation was significant (p < 0.001), with an R2 of 0.44. Only mass and volume observations associated with the strata between 10 and 70 cm were included.
Figure 2. Regression for live woody fuel material with volume as a predictor of mass (mass has been backtransformed from square root). The equation was significant (p < 0.001), with an R2 of 0.44. Only mass and volume observations associated with the strata between 10 and 70 cm were included.
Fire 04 00036 g002
Figure 3. Predicted vs. actual plots for live woody material (A), herbaceous fuel (B), and woody litter (C). Lines represent linear regression with R2 values of 0.37, 0.75, and 0.79 for A, B, and C respectively.
Figure 3. Predicted vs. actual plots for live woody material (A), herbaceous fuel (B), and woody litter (C). Lines represent linear regression with R2 values of 0.37, 0.75, and 0.79 for A, B, and C respectively.
Fire 04 00036 g003
Figure 4. Exponential, nonlinear regression for herbaceous fuel material with both volume and height as predictors of mass. Only mass and volume observations associated with the strata between 0 and 70 cm were included. Using this equation, loading was calculated for each plot pre-fire using the voxelized volume and height (Figure 3). The median (±IQR) fuel consumption was 56.55 ± 10.52 g (Table 3). For the paired plots, the median (±IQR) fuel consumption was 68.41 ± 22.74 g (Table 3).
Figure 4. Exponential, nonlinear regression for herbaceous fuel material with both volume and height as predictors of mass. Only mass and volume observations associated with the strata between 0 and 70 cm were included. Using this equation, loading was calculated for each plot pre-fire using the voxelized volume and height (Figure 3). The median (±IQR) fuel consumption was 56.55 ± 10.52 g (Table 3). For the paired plots, the median (±IQR) fuel consumption was 68.41 ± 22.74 g (Table 3).
Fire 04 00036 g004
Figure 5. Exponential, nonlinear regression for woody litter fuel material with both volume and height as predictors of mass. Only mass and volume observations associated with the strata between 0 and 20 cm were included. Using this equation, loading was calculated for each plot pre-fire using both the voxelized volume and height (Figure 3). The median (±IQR) fuel consumption was 19.83 ± 4.01 g (Table 3). For the paired plots, the median (±IQR) fuel consumption was 20.83 ± 4.53 g (Table 3).
Figure 5. Exponential, nonlinear regression for woody litter fuel material with both volume and height as predictors of mass. Only mass and volume observations associated with the strata between 0 and 20 cm were included. Using this equation, loading was calculated for each plot pre-fire using both the voxelized volume and height (Figure 3). The median (±IQR) fuel consumption was 19.83 ± 4.01 g (Table 3). For the paired plots, the median (±IQR) fuel consumption was 20.83 ± 4.53 g (Table 3).
Fire 04 00036 g005
Figure 6. Fuel consumption in three plots. Photos on the left show pre-burn fuel and photos on the right show fuel remaining post-burn. (A) is a plot with no fuel consumption, (B) is a plot with moderate consumption, and (C) is a plot with complete consumption.
Figure 6. Fuel consumption in three plots. Photos on the left show pre-burn fuel and photos on the right show fuel remaining post-burn. (A) is a plot with no fuel consumption, (B) is a plot with moderate consumption, and (C) is a plot with complete consumption.
Fire 04 00036 g006
Table 1. Bulk density medians and interquartile ranges for the three fuel categories (live woody, herbaceous, and woody litter material) at each stratum (0–100 cm) with sample sizes in parentheses. “NA” indicates strata that either had no observations or a single observation where an average could not be calculated. All numbers represent the average bulk density at that stratum given in kg/m3. Medians within fuel categories are similar if followed by a common letter (p > 0.05). Medians not followed by a letter had less than five observations and were not included in the analyses.
Table 1. Bulk density medians and interquartile ranges for the three fuel categories (live woody, herbaceous, and woody litter material) at each stratum (0–100 cm) with sample sizes in parentheses. “NA” indicates strata that either had no observations or a single observation where an average could not be calculated. All numbers represent the average bulk density at that stratum given in kg/m3. Medians within fuel categories are similar if followed by a common letter (p > 0.05). Medians not followed by a letter had less than five observations and were not included in the analyses.
Bulk Density of Fuel Categories (kg/m3)
Strata (cm)Live WoodyHerbaceousWoody Litter
0–101.05 ± 3.23 a (11)1.56 ± 1.33 a (12)1.35 ± 1.18 a (12)
10–200.97 ± 0.74 a (12)0.41 ± 0.32 b (12)0.38 ± 0.24 b (8)
20–300.84 ± 0.37 a (11)0.14 ± 0.17 c (12)NA
30–400.87 ± 0.42 a (10)0.09 ± 0.04 d (12)NA
40–500.79 ± 0.37 a (8)0.06 ± 0.05 d (11)NA
50–600.60 ± 0.20 a (7)0.05 ± 0.01 d (8)NA
60–700.62 ± 0.20 a (7)0.04 ± 0.01 d (6)NA
70–800.48 ± 0.49 (4)0.13 ± 0.06 (2)NA
80–900.54 ± 0.23 (3)NANA
90–1000.54 ± 0.47 (3)NANA
Table 2. Estimates, R2, and residual standard errors for linear and nonlinear regression equations for the three fuel types predicting mass (kg) based on volume and height. For live woody, only volume was used as a predictor. Standard deviation of estimates in parentheses.
Table 2. Estimates, R2, and residual standard errors for linear and nonlinear regression equations for the three fuel types predicting mass (kg) based on volume and height. For live woody, only volume was used as a predictor. Standard deviation of estimates in parentheses.
Estimate Live WoodyEstimate HerbaceousEstimate Woody Litter
Intercept0.0552 (0.00678)6.96 × 10−8 (2.93 × 10−7)0.00155 (0.00171)
Volume3.16 (0.482)535 (169)143 (45.4)
Height 10–20 cmNA−1.11 (0.228)−0.624 (1.56)
Height 20–30 cmNA−1.40 (0.429)NA
Height 30–40 cmNA−1.43 (0.734)NA
R20.44NANA
Residual Standard Error0.02170.009110.0123
Table 3. Fuel consumption (g) in four plots for each fuel category. Before treatment application, pre-fire and post-fire plots were paired based on dominant fuel type. Fuel consumption in paired plots was calculated by subtracting biomass in post-fire plots from biomass in pre-fire plots within fuel categories. The regression equation for each fuel type was used to estimate biomass present in post-fire plots before the burn from voxel/volume data. Fuel consumption was then calculated by subtracting collected biomass in post-fire plots from estimated biomass in post-fire plots before the burn.
Table 3. Fuel consumption (g) in four plots for each fuel category. Before treatment application, pre-fire and post-fire plots were paired based on dominant fuel type. Fuel consumption in paired plots was calculated by subtracting biomass in post-fire plots from biomass in pre-fire plots within fuel categories. The regression equation for each fuel type was used to estimate biomass present in post-fire plots before the burn from voxel/volume data. Fuel consumption was then calculated by subtracting collected biomass in post-fire plots from estimated biomass in post-fire plots before the burn.
Paired Plots
PlotTypeHerbaceousLive WoodyWoody Litter
1Shrub26.2914.928.8
2Surface73.95−4.2219.89
3Shrub83.9612.0321.77
4Shrub62.8629.2616.32
Median 68.4113.4720.83
Regression Estimates
PlotTypeHerbaceousLive woodyWoody Litter
1Shrub53.08−22.4728.93
2Surface59.002.9519.64
3Shrub54.0912.9420.02
4Shrub62.9229.2514.05
Median 56.557.9519.83
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Hiers, Q.A.; Loudermilk, E.L.; Hawley, C.M.; Hiers, J.K.; Pokswinski, S.; Hoffman, C.M.; O’Brien, J.J. Non-Destructive Fuel Volume Measurements Can Estimate Fine-Scale Biomass across Surface Fuel Types in a Frequently Burned Ecosystem. Fire 2021, 4, 36. https://0-doi-org.brum.beds.ac.uk/10.3390/fire4030036

AMA Style

Hiers QA, Loudermilk EL, Hawley CM, Hiers JK, Pokswinski S, Hoffman CM, O’Brien JJ. Non-Destructive Fuel Volume Measurements Can Estimate Fine-Scale Biomass across Surface Fuel Types in a Frequently Burned Ecosystem. Fire. 2021; 4(3):36. https://0-doi-org.brum.beds.ac.uk/10.3390/fire4030036

Chicago/Turabian Style

Hiers, Quinn A., E. Louise Loudermilk, Christie M. Hawley, J. Kevin Hiers, Scott Pokswinski, Chad M. Hoffman, and Joseph J. O’Brien. 2021. "Non-Destructive Fuel Volume Measurements Can Estimate Fine-Scale Biomass across Surface Fuel Types in a Frequently Burned Ecosystem" Fire 4, no. 3: 36. https://0-doi-org.brum.beds.ac.uk/10.3390/fire4030036

Article Metrics

Back to TopTop