Next Article in Journal
Understanding Land Changes for Sustainable Environmental Management: The Case of Basilicata Region (Southern Italy)
Next Article in Special Issue
Quantification of Platinum in Edible Mushrooms Using Voltammetric Techniques
Previous Article in Journal / Special Issue
Bisphenol A: Quantification in Complex Matrices and Removal by Anaerobic Sludges
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Determination of Antibiotics, Pesticides, Herbicides, Fungicides and Hormones in Water Bodies in Italy in Occurrence with European Watch List Mechanism by Using an UHPLC-MS/MS System: Method Validation, Quantification and Evaluations

1
Agenzia Regionale per la Protezione dell’Ambiente della Lombardia (ARPA Lombardia), Settore Laboratori, sede di Via Rosellini 17, 20124 Milano, Italy
2
Istituto Superiore per la Protezione e la Ricerca Ambientale, Via V. Brancati 48, 00144 Rome, Italy
*
Author to whom correspondence should be addressed.
Submission received: 30 July 2021 / Revised: 18 October 2021 / Accepted: 20 October 2021 / Published: 25 October 2021
(This article belongs to the Special Issue Analysis of Trace Pollutants in Complex Matrices)

Abstract

:
In recent years, the quality of aquatic ecosystems has received increasing attention from European institutions. The Commission Implementing Decision (EU) 2018/840 drafted a Watch List (WL) of compounds to be monitored in Europe. In this study, we report a method based on solid phase extraction with ultra-high-performance liquid chromatography, coupled with a triple-quadrupole mass spectrometer (UHPLC-MS/MS) to analyze the whole water sample. The method was developed and validated for the determination of 12 listed compounds. The employment of solid-phase extraction by a horizon system ensures the analysis of the entire body of samples and minimizes sample manipulation. Different ng L−1 detection limits (from 2 to 50 ng L−1), linearities (from 2 to 500 ng L−1), accuracy (from 70 to 130%) and levels of precision (RSD less 20% at LOQs levels) were assessed to be satisfactory for quantification and confirmation at the levels of interest. The developed method was applied for quantitative analysis for Watch List compounds (with the exception of hormones) in surface water samples from different Italian sites during monitoring activities by the Regional Environmental Protection Agencies in the years 2019 and 2020.

1. Introduction

The last twenty years were characterized by increasing interest in environmental sustainability and health protection [1,2,3,4,5,6]. In this context, scientific and governmental organizations focused their attention on improving environmental protections and living conditions [7].
Regarding governmental organizations, the European Union, from the 2000s, has been making efforts aimed at protecting water bodies [8]. The most important actions were the Directive 2000/60/EC, commonly known as the Water Framework Directive (WFD), and the Directive 2010/75/EU on industrial emissions, which regulates the discharge of chemicals from industrial activities. These directives aim to achieve a good chemical status for surface and groundwater in the European Union. To reach this goal, it is important to take actions to monitor water bodies.
In 2015 there was a real innovative reform with the first Watch List (WL) investigation for new emerging substances [9]. The first WL included several substances, such as sunscreens, drugs, hormones, neonicotinoids, pesticides and antibiotics [9].
One of the main problems of the first WL was the low quantification limit (LOQ) required—17-α ethylenestradiol (EE2) (0.035 ng L−1). However, several EU states have developed methods to achieve an LOQ of 0.035 ng L−1 for EE2, and data collected by different Member States were presented and discussed during a Joint Research Center (JRC) dissemination meeting at ISPRA [10].
WFD actions were improved and, in 2018, the European Commission reviewed several substances compared to the first Watch List [9]. For example, cinnamate and oxadiazon were eliminated and other substances widely used in everyday life were added. Among the new substances, two antibiotics (Amoxicillin and Ciprofloxacin) and one pesticide (Metaflumizone) were added in the second WL [11]. Indeed, antibiotics are becoming increasingly problematic contaminants of water sources such as surface and ground water, which are located near industrial and domestic communities.
Furthermore, during the JRC meeting, member states agreed that analyses will be performed of whole water samples. Although these substances are widely used in everyday life, their determination in water can be considered a challenge in analytical chemistry. In fact, these substances show instability/precipitation in water or several organic solvents due to their fast degradation and chemical reaction properties. Several authors performed studies on development methods for the determination of Amoxicillin, Ciprofloxacin and Metaflumizone in water; however, these research papers describe the determination of these substances at very high concentration levels (µg L−1) and were performed on filtrated water samples [12,13,14].
Several studies reported analytical techniques that can determine antibiotics in various environmental samples using ultra-high-performance liquid chromatography (UHPLC) or capillary electrophoresis [14,15]. Usually, the analysis was carried out after a pre-concentration step, such as solid phase extraction (SPE), followed by a liquid chromatographic (LC) determination. Unfortunately, due to differences in the physical-chemical properties, such as water solubility and stability, of several substances included in WL analyses, it is not possible to perform a single extraction-procedure step.
Moreover, since the analysis of such substances must be carried out throughout Europe on a routine basis, a comprehensive, multiresidue analytical method represents a useful tool to comply with the European Decision.
In this study, we report an analytical method which is able to determine 12 compounds relevant to the 2018–2020 WL using SPE extraction procedures coupled with ultra-high-performance liquid chromatography mass spectrometry. These compounds include antibiotics, fungicide, and herbicide. The determination of three hormones, Estrone (E1), 17α-Ethynylestradiol (EE2) and 17 β-Estradiol (E2), which belong to the WL 2018–2020, was performed using a method presented in a previous paper [16].
Special attention was dedicated to Amoxicillin determination due to its degradation and epimer formation processes.
The aim of this work was to develop a precise, reproducible, and rapid ultra-high-performance liquid chromatography (UHPLC) method applicable to the determination of several analytes for Watch List 2018. The method was applied to the monitoring of 10 rivers in 10 regions of Italy.

2. Materials and Methods

2.1. Chemicals and Reagents

Amoxicillin, Ciprofloxacin, Azithromycin, Clarithromycin, Erythromycin, Metaflumizone, Imidacloprid, Methiocarb, Thiacloprid, Thiamethoxam, Clothianidin, Acetamiprid, Estrone (E1), 17α-Ethynylestradiol (EE2), and β-Estradiol (E2) were obtained from LabService Analytica. The CAS number for each compound is reported in Table 1.
Isotopically labeled compounds, used as internal standards (IS), were chosen according to the chemical properties and retention times of the analytes, and were purchased from LabService Analytica. The purity grade of all standards was always above 94%.
Mixed stock solutions were prepared by serial dilution in acetonitrile (ACN) and stored at −20 °C in the dark to avoid possible photodegradation. To obtain a mix solution at 250 µg L−1 in ACN, 25 µL of each compound at 100 µg mL−1 was diluted with 10 mL of acetonitrile. After that, 200 µL of mix solution at 250 µg L−1 was diluted with 10 mL of ACN to obtain a mix solution at 5 µg L−1. Calibration standard solutions were prepared from 2 to 500 ng L−1 in water + ACN mixture (75:25) by serial dilution from mix solution at 5 µg L−1.
Intermediate mixed solutions containing all analytes and all labeled compounds, were prepared weekly. Aqueous acetonitrile (75:25) working standard solutions were renewed before every analytical run to prevent precipitation.
For Amoxicillin analyses, calibration standards were prepared differently by adding 10 µL of formic acid solution (1%) at 1 mL of the calibration standard.
High-purity water was prepared using a Millipore Milli-Q purification system.
Stock solutions were prepared in methanol and were stored at −18 °C in amber glassware. To avoid standard degradation, Calibration Working solutions were prepared by serial dilutions of stock solutions in Milli-Q water before each calibration. After reviewing the literature data [17] concerning SPE extraction procedures, Empore™ SPE Disks matrix active group polystyrene-divinylbenzene (SDB-XC), diam. 47 mm, was used as a disk, coupled with a SPE-DEX 5000 Horizon Technology for extraction procedures.
LC/MS Acetonitrile grade solvents and formic acid 98% were acquired from (Merck), Milli Q water was obtained by the in-house Milli Q system.

2.2. Sample Collection and Preparation

Surface water samples were collected in 1 L PET bottles and refrigerated at 4 °C during transport.
Twenty-eight real samples were collected from different regions of Italy and shipped to the laboratory. The sampling stations and number of measurements performed for each region by the laboratory of ARPA Lombardia are reported in Table 2 and Table 3, respectively. Sampling was carried out in accordance with EU directives [9].

3. Results

3.1. Solid Phase Extraction Procedures

Collected samples were extracted without filtration for 5 days using SPE with SPE-DEX 5000 Horizon Technology.
To analyze the whole water sample, after references, analyses and chemical consideration of the different solubility of compounds, the authors decided to use SPE-DEX system. This was not used to concentrate compounds, but to eluate the compounds adsorbed to particulate matter.
The operating conditions for solid-phase extraction procedures using SPE-DEX 5000 Horizon Technology are reported in Table 4.
Using this procedure, all analytes without solubility differences were collected in water + acetonitrile 100 + 25 v/v.

3.2. LC-MS Instrumentation

Separations were performed using an ultra-high-performance liquid chromatograph (UHPLC) consisting of a binary pump EXION LC Sciex pump.
The EXION LC SCIEX system was coupled with a 6500 plus Q-Trap mass spectrometer (Sciex), equipped with a Turbo V® interface by an ESI probe.
The experimental operating conditions were optimized by standard infusion to detect the best ionization conditions and fragmentation.
Mass spectrometry optimal parameters and transition are reported in Table 5 and Table 6, respectively.
The compounds were separated using a CORTEX T3 analytical column (150 mm, 4.6 mm, 5 μm). The mobile phase consisted of water + 0.02% of formic acid and acetonitrile. Elution conditions are reported in Table 7.
Analysis was performed by multiple reaction monitoring (MRM) in both positive and negative ionization modes using m/z, declustering potential and collision energy, as reported in Table 3 and Table 4.
Analytes were identified both by comparing their retention times (RT) with the RT of the standards and using qualifier ions. Two selected reaction monitoring (SRM) transitions were recorded for each compound: one for quantification and the other one for confirmation. Time-specific SRM windows were set for each retention time to enhance the sensitivity.
The whole system was controlled via the Analyst software (SCIEX), while quantification of the analytes was performed with multi-quant 3.0 (SCIEX).
Quantification was based on the peak area for each compound, and baselines were adjusted manually when necessary.
Hormones were investigated using a previously validated method, as reported in the literature [16].

3.3. Method Validation and Quality Control

The method was validated according to the acceptance criteria reported in several guidelines used in Europe. Method validation was performed in accordance with the European SANTE and UNI EN ISO and 17025 guidelines [18,19].
The linearity of the method was investigated by analyzing standard solutions in triplicate at eight concentrations, ranging from 2 to 500 ng L−1. Satisfactory linearity was assumed when the determination coefficient (R2) was higher than 0.997 based on relative responses (analyte peak area/labelled internal standard peak area), and the residuals were lower than 20%. Accuracy (expressed as percentage recovery) and precision (repeatability, expressed as relative standard deviation in percentage) were evaluated by analyzing three different surface water samples (SW) without the target analytes (previously analyzed), and fortified at several concentration levels for all compounds. The results are reported in Table 8.
The limits of quantification (LOQs) were determined both by 10 × standard deviation (Sr) of signal at the first calibration curve level and in terms of S/N, as reported in Table 9.

3.4. Analyses and Application to Environmental Samples

The developed method was applied to evaluate the concentration of the Watch List compounds.
Solid Phase Extraction, for the analyses of whole water samples, was carried out by means of an SPE-DEX 5000 Horizon Technology, as described in Section 2.2. Eluted water and organic phases were added to the internal standard and analyzed with an LC-MS/MS system, as described in Section 3.2. In brief, calibration curves were prepared for each batch analysis in the range from 2 to 500 ng L−1 depending on the quantified analyte. The injection volume was set at 50 µL. Separation was obtained using a Cortex T3 under elution conditions, as reported in Table 7.
Quality control solutions were analyzed at the beginning, after every ten samples and at the end of the batch analyses. The entire method was subjected to validation and quality control procedures.
For results concerning Analyte EE2, E2 and E1, analyses were performed using a method previously validated and reported in the literature [16].
In brief, 1 L of the water sample was extracted by an SPE off-line. Then, 5 mL of reconstituted extract was injected in an SPE on-line system, coupled with high-performance liquid chromatography tandem mass spectrometry (HPLC–MS/MS) using negative electrospray ionization.
The obtained results are summarized in Table 10 and Table 11.
The concentrations of the Watch List compound were below the adopted LOQ in most cases.
Clothianidin, Methiocarb, Thiamethoxam, Metaflumizone, and 17-α-ethinylestradiol were not detected in all samples collected during 2019–2020.
Acetamiprid was found in two samples in 2019, at 115 ng L−1 and 11 ng L−1. Imidacloprid was detected in seven samples in 2020, at different concentration levels ranging from 7 to 24 ng L−1. Thiacloprid was detected in only one sample in 2019 and in 2020, at 29 ng L−1 and 10 ng L−1, respectively.
Regarding hormones, only Estrone and 17-β-estradiol were detected in different samples (in 2019 from 0.16 to 7.98 and in 2020 from 0.37 to 3.25 ng L−1) and Estrone was detected at a higher level than 17-β-estradiol.
Among the antibiotics, Azithromycin and Clarithromycin were most frequently detected. Azithromycin was detected at high level in 2019 in Lombardy (261 ng L−1) and in the sample collected in 2020, at a concentration of 200 ng L−1, in the Calabria region.
These data can be ascribed to the use of Azithromycin as an antibiotic in COVID-19 treatment.
The observed results are in the same concentration range as described in other studies [20,21]. Erythromycin was found at lower concentration levels, probably due to the conversion and secondary reactions, as reported in the literature [22,23].
Amoxicillin and Ciprofloxacin were only detected in samples collected in 2019, because, due to the COVID-19 pandemic, WL sample collections in 2020 were only carried out in July.

4. Conclusions

In this study, an analytical method was developed and validated for the detection of several substances concerning Decision 2018/840/EU in waters. A solid-phase extraction coupled with HPLC-MS/MS was used to obtain the data by analyzing whole samples of water during Watch List activity in Italy.
The validated method was able to identify and quantify twelve compounds at concentration levels ranging from 0.16 to 261 ng L−1. Method Detection limits from 0.035 to 2.24 ng/L for hormones, and from 2 to 50 ng L−1 for other compounds were achieved, as well as a linearity ranging from 2 to 500 ng L−1, accuracy ranging from 70 to 130%, and a precision RSD of less than 20% at LOQs levels.
The developed method was used to monitor 28 analyzed samples for a total of 11 sample sites, and low-level contamination was found.

Author Contributions

Conceptualization, S.B. (Salvatore Barreca) and L.C. (Luisa Colzani); methodology, S.B. (Salvatore Barreca) and L.C. (Luisa Colzani); software, S.B. (Salvatore Barreca), M.B. and C.F.; validation, S.B. (Salvatore Barreca), M.B., C.F. and L.C. (Luisa Colzani); formal analysis, S.B. (Salvatore Barreca), M.B. and C.F.; writing—original draft preparation, S.B. (Salvatore Barreca), L.C. (Luisa Colzani) and D.D. project administration, S.B. (Stefania Balzamo), E.C., M.P., L.C. (Luisa Colzani), L.C. (Laura Clerici) and P.D. All authors have read and agreed to the published version of the manuscript.

Funding

The study was supported by a Regione Lombardia financial source.

Conflicts of Interest

The authors declare no conflict of interest. The findings and conclusions of this article are solely the responsibility of the authors and do not represent the official views of ARPA Lombardia.

References

  1. Pinion, C., Jr.; Hisel, J.D. Public Health Needs the National Environmental Health Science and Protection Accreditation Council and the Council on Education for Public Health. J. Environ. Health 2020, 82, 26–28. [Google Scholar]
  2. Regulation (EC) No 1907/2006 of the European Parliament and of the Council of 18 December 2006 Concerning the Registration, Evaluation, Authorisation and Restriction of Chemicals.
  3. Barreca, S.; Orecchio, S.; Pace, A. Photochemical sample treatment for extracts clean up in PCB analysis from sediments. Talanta 2013, 103, 349–354. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  4. Barreca, S.; Busetto, M.; Vitelli, M.; Colzani, L.; Clerici, L.; Dellavedova, P. Online solid-phase extraction LC-MS/MS: A rapid and valid method for the determination of perfluorinated compounds at sub ng·L−1 Level in natural water. J. Chem. 2018, 2018, 3780825. [Google Scholar] [CrossRef] [Green Version]
  5. Bergamasco, A.; Culotta, L.; De Stefano, C.; Orecchio, S.; Sammartano, S.; Barreca, S. Composition, distribution, and sources of polycyclic aromatic hydrocarbons in sediments of the Gulf of Milazzo (Mediterranean Sea, Italy). Polycycl. Aromat. Compd. 2014, 34, 397–424. [Google Scholar] [CrossRef]
  6. Orecchio, S.; Fiore, M.; Barreca, S.; Vara, G. Volatile profiles of emissions from different activities analyzed using canister samplers and gas chromatography-mass spectrometry (GC/MS) analysis: A case study. Int. J. Environ. Res. Public Health 2017, 14, 195. [Google Scholar] [CrossRef] [Green Version]
  7. Directive 2008/105/EC of 16 December 2008 on Environmental Quality Standards in the Field of Water Policy, Amending and Subsequently Repealing Council Directives 82/176/EEC, 83/513/EEC, 84/156/EEC, 84/491/ECC, 86/280/ECC and Amending Directive 2000/60/EC.
  8. Todo, K.; Sato, K. Directive 2000/60/EC of the European Parliament and of the Council of 23 October 2000 establishing a framework for Community action in the field of water policy. Environ. Res. Q. 2002, 66–106. [Google Scholar]
  9. Decision, E.U. Commission implementing decision (EU) 2015/495 of 20 March 2015 establishing a watch list of substances for Unionwide monitoring in the field of water policy pursuant to Directive 2008/105/EC of the European Parliament and of the Council. Off. J. Eur. Union L. 2015, 78, 40–42. [Google Scholar]
  10. Loos, R.; Marinov, D.; Sanseverino, I.; Lettieri, T. Analytical methods for substances in the Watch List under the Water Framework Directive. In Proceedings of the JRC Conference and Workshop Reports, Ispra, Italy, 1–2 March 2018. [Google Scholar]
  11. Implementing decision 2018/840—Watch list of substances for Union-wide monitoring in the field of water policy pursuant to Directive 2008/105/EC repealing Commission Implementing Decision (EU) 2015/495 (notified under document C (2018) 3362).
  12. Unutkan, T.; Bakırdere, S.; Keyf, S. Development of an analytical method for the determination of amoxicillin in commercial drugs and wastewater samples, and assessing its stability in simulated gastric digestion. J. Chromatogr. Sci. 2018, 56, 36–40. [Google Scholar] [CrossRef] [PubMed]
  13. Prutthiwanasan, B.; Phechkrajang, C.; Suntornsuk, L. Fluorescent labelling of ciprofloxacin and norfloxacin and its application for residues analysis in surface water. Talanta 2016, 159, 74–79. [Google Scholar] [CrossRef] [PubMed]
  14. Borrull, J.; Colom, A.; Fabregas, J.; Borrull, F.; Pocurull, E. Liquid chromatography tandem mass spectrometry determination of 34 priority and emerging pollutants in water from the influent and effluent of a drinking water treatment plant. J. Chromatogr. A 2020, 1621, 461090. [Google Scholar] [CrossRef] [PubMed]
  15. Jafari Ozumchelouei, E.; Hamidian, A.H.; Zhang, Y.; Yang, M. Physicochemical properties of antibiotics: A review with an emphasis on detection in the aquatic environment. Water Environ. Res. 2020, 92, 177–188. [Google Scholar] [CrossRef] [PubMed]
  16. Barreca, S.; Busetto, M.; Colzani, L.; Clerici, L.; Daverio, D.; Dellavedova, P.; Ubaldi, V. Determination of estrogenic endocrine disruptors in water at sub-ng L−1 levels in compliance with Decision 2015/495/EU using offline-online solid phase extraction concentration coupled with high performance liquid chromatography-tandem mass spectrometry. Microchem. J. 2019, 147, 1186–1191. [Google Scholar] [CrossRef]
  17. Dabbagh, M.S.; Farajzadeh, M.A. Introduction of a new procedure for the synthesis of polysulfone magnetic nanoparticles and their application in magnetic solid phase extraction for the extraction of some pesticides from fruit and vegetable juices. Microchem. J. 2020, 158, 105238. [Google Scholar] [CrossRef]
  18. Guidance document on analytical quality control and method validation procedures for pesticides residues analysis in food and feed. SANTE/11945/2015 Supersedes SANCO/12571/2013 Implemented by 01/01/2016.
  19. UNI CEI EN ISO/IEC 17025:2018.
  20. Verlicchi, P.; Al Aukidy, M.; Zambello, E. Occurrence of pharmaceutical compounds in urban wastewater: Removal, mass load and environmental risk after a secondary treatment—A review. Sci. Total 2012, 429, 123–155. [Google Scholar] [CrossRef] [PubMed]
  21. Gusmaroli, L.; Insa, S.; Petrovic, M. Development of an online SPE-UHPLC-MS/MS method for the multiresidue analysis of the 17 compounds from the EU “Watch list”. Anal. Bioanal. Chem. 2018, 410, 4165–4176. [Google Scholar] [CrossRef] [PubMed]
  22. Dolar, D.; Gros, M.; Rodriguez-Mozaz, S.; Moreno, J.; Comas, J.; Rodriguez-Roda, I.; Barceló, D. Removal of emerging contaminants from municipal wastewater with an integrated membrane system, MBRRO. J. Hazard. Mater. 2012, 239–240, 64–69. [Google Scholar] [CrossRef] [PubMed]
  23. Hirsch, R.; Ternes, T.; Haberer, K.; Kratz, K.L. Occurrence of antibiotics in the aquatic environment. Sci. Total Environ. 1999, 225, 109–118. [Google Scholar] [CrossRef]
Table 1. List of analyzed compounds, cas number identification and LOQ required.
Table 1. List of analyzed compounds, cas number identification and LOQ required.
Name of Substance/Group of SubstancesCAS NumberMaximum Acceptable Method Detection Limit (ng/L)
17-α-ethinylestradiol (EE2)57-63-60.035
17-β-estradiol (E2), Estrone (E1)50-28-2,
53-16-7
0.4
Macrolide antibiotics (1) 19
Methiocarb2032-65-72
Neonicotinoids (2) 8.3
Metaflumizone139968-49-365
Amoxicillin26787-78-078
Ciprofloxacin85721-33-189
(1) Eritromicina (CAS 114-07-8), claritromicina (CAS 81103-11-9), azitromicina (CAS 83905-01-5). (2) Imidacloprid (CAS 105827-78-9/138261-41-3), tiacloprid (CAS 111988-49-9), tiametoxam (CAS 153719-23-4), clotianidin (CAS 210880-92-5), acetamiprid (CAS (135410-20-7/160430-64-8).
Table 2. WL sampling stations in 2019 and 2020; RW stands for river water.
Table 2. WL sampling stations in 2019 and 2020; RW stands for river water.
Station CodeTypeItalian Region
WL_S1RWValle d’Aosta
WL_S2RWPiedmont
WL_S3RWPiedmont
WL_S4RWLombardy
WL_S5RWTrentino Alto Adige (Trento)
WL_S6RWLiguria
WL_S7RWTuscany
WL_S8RWUmbria
WL_S9RWMolise
WL_S10RWCampania
WL_S11RWCalabria (only in 2020)
Table 3. Number of measurements carried out by the laboratory in 2019 and 2020 for Watch List.
Table 3. Number of measurements carried out by the laboratory in 2019 and 2020 for Watch List.
Italian RegionSampling SitesSampling Campaign
(2019 and 2020)
WL Analyses
(2019 and 2020)
Campania1330
Liguria1330
Lombardy1330
Molise1330
Piedmont2345
Tuscany1330
Trentino Alto Adige1330
(Trento)
Umbria1330
Valle D’Aosta1330
Calabria1115
Total1128300
Table 4. Operating conditions for SPE procedures.
Table 4. Operating conditions for SPE procedures.
Method StepsEluent UsedExhaust Line or Sample Line
Condition SPE Disk10 mL AcetonitrileExhaust line
Load Sample100 mL samplesSample line
Elute Sample Container25 mL AcetonitrileSample line
Air Dry Disk Timer30 s by nitrogenSample line
Pause
Clean System20 mL Methanol/water 50/50Exhaust line
Table 5. Mass spectrometry general conditions.
Table 5. Mass spectrometry general conditions.
ParametersUnitValue
Curtain Gas (CUR)psi30
Collision Gas-Medium
Ion Spray Voltage (IS)V4500
Temperature TEM (GS2)°C450
Ion Source Gas (GS1)psi55
Ion Source Gas (GS2)psi60
Table 6. Analyte, m/z transitions and operating parameters.
Table 6. Analyte, m/z transitions and operating parameters.
AnalyteQ1
Precursion Ion [M + H]+
(m/z)
Q3
Product Ion
(m/z)
Declustering Potential
(DP)
Entrance Potential (EP)Collision Energy (CE)Collision Exit Potential
(CXP)
Acetamiprid-1223.1126.135103110
Acetamiprid-2223.156.135102710
Azithromycin-1749.5591.340104612
Azithromycin-2749.5158.140104612
Clothianidin-1250.1168.920101910
Clothianidin-2250.113220102313
Clarithromycin-1748.559040103010
Clarithromycin-2748.515840103010
Metaflumizone-150717870103510
Metaflumizone-250711670103010
Methiocarb-1226.216930101410
Methiocarb-2226.212130102510
Erythromycin-1734.557660103010
Erythromycin-2734.5158.360103010
Imidacloprid-1256.220961102316
Imidaclorpid-2256.2175.261102314
Amoxicillin-136620825101610
Amoxicillin-236611425101610
Thiacloprid-1253.1126.140102910
Thiacloprid-2253.118640102310
Thiamethoxam-129221170101710
Thiamethoxam-229218170103010
Ciprofloxacin-133228827103410
Ciprofloxacin-233224527103110
Table 7. Cortex T3 chromatographic separation column elution conditions.
Table 7. Cortex T3 chromatographic separation column elution conditions.
Time (min)Flow (mL/min)% Water + 0.02% in Formic Acid% Acetonitrile
0.00.359010
0.10.359010
9.00.35298
10.00.35298
10.10.359010
12.00.359010
Table 8. Accuracy and repeatability obtained from several levels.
Table 8. Accuracy and repeatability obtained from several levels.
AnalyteSpiked Sample Concentration ng/LObtained Value (ng/L)Accuracy%CV%
Acetamiprid2018.9294.65.597
5058.30116.64.77
100111111.611.2
25022188.45.90
Clothianidin2024.7123.710.7
5046.2392.459.06
100104.0104.010.3
25022088.06.49
Imidacloprid2018.6993.477.98
5050.86101.711.9
10097.3297.324.57
25018975.602.30
Methiocarb2021.11105.67.56
5056.05112.16.45
100101.9101.96.35
250216.8686.743.55
Thiacloprid2022.5112.58.91
5054.10108.25.30
100107.3107.35.70
250232.3092.923.41
Thiamethoxam2019.64998.2510.2
5051.261102.29.88
10088.2488.247.80
250189.075.616.70
Methiocarb22.229111.50.19
5044.7189.426.42
100104.50104.52.73
250224.796.6681.7
Metaflumizone5046.48792.9718.3
10087.7487.7418.0
250193.177.2213.6
Amoxicillin10082.8782.876.66
250203.8381.537.50
500448.789.756.09
Ciprofloxacin5050.8696.5811.9
10092.9492.9413.7
25022088.06.49
Azithromycin5048.7097.408.49
10082.8882.886.55
250216.786.667.97
Clarithromycin5043.8687.709.95
10080.1280.126.11
25021083.986.63
Erythromycin5048.28896.587.19
10093.70693.7015.93
25022188.559.00
Table 9. Obtained limit of quantification.
Table 9. Obtained limit of quantification.
AnalyteLOQ Considering 10 × Standard Deviations (Sr) of Signal at First Calibration Level (ng/L)Signal/Noise at LOQ Levels
Acetamiprid5227
Clothianidin559
Imidacloprid582
Methiocarb226
Thiacloprid5163
Thiamethoxam541
Azithromycin10335
Clarithromycin10560
Erythromycin1060
Metaflumizone50990
Amoxicillin5022
Ciprofloxacin5066
Table 10. 2019 Watch List measurements in ng L−1.
Table 10. 2019 Watch List measurements in ng L−1.
WL Sampling SiteWL_S10WL_S6WL_S4WL_S3WL_S2WL_S7WL_S5WL_S8WL_S1WL_S9
EE2<0.035<0.035<0.035 <0.035<0.035<0.035<0.035<0.035<0.035
E2<0.100.812.66 0.32<0.10<0.100.810.21<0.10
E10.161.897.98 0.702.400.231.180.270.54
Erythromycin<10<10<10 <1038<10<10<10<10
Clarithromycin2538164 <1084122160<10
Azithromycin1918261 <103728<10144<10
Methiocarb<2<2<2<2 <2<2<2<2<2
Imidacloprid<517812<5 81<5<5<5<5
Thiacloprid<5<5<5<5 29<5<5<5<5
Thiamethoxam<5<5<5<5 <5<5<5<5<5
Clothianidin<5<5<5<5 <5<5<5<5<5
Acetamiprid<5115<5<5 11<5<5<5<5
Metaflumizone<50<50<50<50 <50<50<50<50<50
Amoxicillyn56<50134 <50<50<50<5065<50
Ciprofloxacin182<50<50 <50<5059<5069<50
Table 11. 2020 Watch List measurements in ng L−1.
Table 11. 2020 Watch List measurements in ng L−1.
WL Sampling SiteWL_S10WL_S6WL_S4WL_S3WL_S2WL_S7WL_S5WL_S8WL_S1WL_S9WL_S11
EE2<0.035<0.035<0.035<0.035<0.035<0.035<0.035<0.035<0.035<0.035<0.035
E2<0.10<0.10<0.100.50.44<0.10<0.10<0.10<0.10<0.10<0.10
E13.251.001.500.50.902.2<0.100.9<0.100.370.4
Erythromycin<10<10<10<10<10<10<10<10<10<10<10
Clarithromycin<10<10<10<10<10<10<10<10<10<10<10
Azithromycin<10<1052<10<1097<10<1050<10221
Methiocarb<2<2<2<2<2<2<2<2<2<2<2
Imidacloprid12810<5724<58<57<5
Thiacloprid<5<5<5<5<510<5<5<5<5<5
Thiamethoxam<5<5<5<5<5<5<5<5<5<5<5
Clothianidin<5<5<5<5<5<5<5<5<5<5<5
Acetamiprid<5<5<5<5<5<5<5<5<5<5<5
Metaflumizone<50<50<50<50<50<50<50<50<50<50<50
Amoxicillyn<50<50<50<50<50<50<50<50<50<50<50
Ciprofloxacin<50<50<50<50<50<50<50<50<50<50<50
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Barreca, S.; Busetto, M.; Forni, C.; Colzani, L.; Clerici, L.; Daverio, D.; Balzamo, S.; Calabretta, E.; Peleggi, M.; Dellavedova, P. Determination of Antibiotics, Pesticides, Herbicides, Fungicides and Hormones in Water Bodies in Italy in Occurrence with European Watch List Mechanism by Using an UHPLC-MS/MS System: Method Validation, Quantification and Evaluations. Pollutants 2021, 1, 207-216. https://0-doi-org.brum.beds.ac.uk/10.3390/pollutants1040017

AMA Style

Barreca S, Busetto M, Forni C, Colzani L, Clerici L, Daverio D, Balzamo S, Calabretta E, Peleggi M, Dellavedova P. Determination of Antibiotics, Pesticides, Herbicides, Fungicides and Hormones in Water Bodies in Italy in Occurrence with European Watch List Mechanism by Using an UHPLC-MS/MS System: Method Validation, Quantification and Evaluations. Pollutants. 2021; 1(4):207-216. https://0-doi-org.brum.beds.ac.uk/10.3390/pollutants1040017

Chicago/Turabian Style

Barreca, Salvatore, Maddalena Busetto, Carola Forni, Luisa Colzani, Laura Clerici, Daniela Daverio, Stefania Balzamo, Elisa Calabretta, Massimo Peleggi, and Pierluisa Dellavedova. 2021. "Determination of Antibiotics, Pesticides, Herbicides, Fungicides and Hormones in Water Bodies in Italy in Occurrence with European Watch List Mechanism by Using an UHPLC-MS/MS System: Method Validation, Quantification and Evaluations" Pollutants 1, no. 4: 207-216. https://0-doi-org.brum.beds.ac.uk/10.3390/pollutants1040017

Article Metrics

Back to TopTop