Connections in Concrete Volume 2

A special issue of CivilEng (ISSN 2673-4109). This special issue belongs to the section "Structural and Earthquake Engineering".

Deadline for manuscript submissions: closed (20 May 2023) | Viewed by 31169

Special Issue Editor


E-Mail Website
Guest Editor
Lyles School of Civil Engineering, Purdue University, West Lafayette, IN 47907-2051, USA
Interests: performance based design of RC structures; static and dynamic testing of RC structures and sub-assemblages; seismic retrofitting of structures with innovative techniques; seismic behavior of cast-in and post-installed anchors in concrete; anchorages with supplementary reinforcement; numerical modeling of structures under seismic loads; modeling of anchorages for interaction between structure and equipment; impact behavior of reinforced concrete structures; fracture mechanics of concrete structures; modeling of bond between reinforcement and concrete; performance of RC structures subjected to fire loads; structural applications of new concrete based materials
Special Issues, Collections and Topics in MDPI journals

Special Issue Information

Dear Colleagues,

Connections in a concrete structure are established either in the form of anchors (or fasteners) connecting structural or nonstructural components to the structure, or in the form of reinforcement embedded in concrete or as part of a steel–concrete composite construction. To ensure structural integrity, it is essential to form a reliable connection between steel and concrete. A well-performing anchorage (fastening) is a must to ensure the interaction between the components connected to the structure and the structure itself. The required flow of forces from concrete to steel and vice versa is established through a sufficient bond between reinforcement and concrete. The anchorage zones are crucial for desirable interaction between concrete and steel structural members in a composite construction. Thus, in principle, the integrity of the entire structure relies heavily on the connections between steel and concrete.

With the advancement in production technologies, new products such as post-installed anchors, anchor channels, high-strength-reinforcing bars, nonmetallic reinforcement, etc. are being developed, and it is essential to verify their performance in concrete. Similarly, the compatibility of newly developed concrete-based materials such as high-performance concrete, fiber-reinforced concrete, geopolymer concrete, etc. with anchorages and reinforcement must be verified.

Practical and innovative solutions are needed for connections in real-life situations, and corresponding reliable design models are needed. In particular, the design models for anchorages are rather limited in scope, and many design issues need to be addressed. Some of these include various geometric configurations, anchorages under seismic loading, anchorages with supplementary reinforcement, anchor channels under different loading combinations, fatigue behavior, long-term performance, influence of corrosion on performance of anchorages, anchorages under extreme loading, etc. Not only is experimental research needed to answer these questions, but new numerical modeling approaches also need to be developed for deeper understanding of the topics.

Another very important aspect is the harmonization of design methods. For example, post-installed reinforcement can be designed either as an anchorage following the principles of fastening technology or as a reinforcing bar following the principles of reinforced concrete. However, the two principles generally lead to quite different design solutions. Similarly, the fastening technology principles require the base plate connecting different anchors to be rigid and stiff elastic, while composite construction principles recommend designing the base plate for yielding. These approaches need harmonization.

Often, the performance of structures under extreme hazards of earthquakes, impact or fire is dominated by the performance of their connections. Reliable design of connections against such hazards calls for performance-based approaches where the compatibility requirements between different components are accounted for.

Every type of strengthening needs a certain type of anchorage. The performance of the strengthening largely depends on the performance of the anchorage itself. Extremely high and challenging demands are imposed on the anchorages used in strengthening (e.g., seismic strengthening). Some of these include high forces, large crack widths, combined load and crack cycling, limited area and depth to develop the required resistance, limited access due to existing reinforcement, etc. Innovative strengthening methods along with anchorage techniques need to be developed that would allow the strengthening to serve its desired function and ensure the safe functioning of the structure.

The proposed Special Issue targets the abovementioned issues in the field of connections in concrete and offers a platform to researchers and experts worldwide to showcase their work. Currently, there is no journal that is dedicated to the problems of connections in concrete, and therefore, publications in this field are often directed to journals that provide a more general scope. In the experience of the proposer, it is often quite difficult to find a suitable journal to present the work in the field of connections in concrete. This issue would offer a new chance to hundreds of researchers working in the field of connections in concrete to publish their work. Additionally, since connections in concrete are, in general, not widely covered in classroom teaching, practitioners and consultants often look for innovative answers and solutions to their problems. This issue would offer them a place to look for such innovative solutions.

Dr. Akanshu Sharma
Guest Editor

Manuscript Submission Information

Manuscripts should be submitted online at www.mdpi.com by registering and logging in to this website. Once you are registered, click here to go to the submission form. Manuscripts can be submitted until the deadline. All submissions that pass pre-check are peer-reviewed. Accepted papers will be published continuously in the journal (as soon as accepted) and will be listed together on the special issue website. Research articles, review articles as well as short communications are invited. For planned papers, a title and short abstract (about 100 words) can be sent to the Editorial Office for announcement on this website.

Submitted manuscripts should not have been published previously, nor be under consideration for publication elsewhere (except conference proceedings papers). All manuscripts are thoroughly refereed through a single-blind peer-review process. A guide for authors and other relevant information for submission of manuscripts is available on the Instructions for Authors page. CivilEng is an international peer-reviewed open access quarterly journal published by MDPI.

Please visit the Instructions for Authors page before submitting a manuscript. The Article Processing Charge (APC) for publication in this open access journal is 1200 CHF (Swiss Francs). Submitted papers should be well formatted and use good English. Authors may use MDPI's English editing service prior to publication or during author revisions.

Keywords

  • cast-in anchorages including anchor channels
  • bond between reinforcement and concrete
  • anchorages in composite construction
  • anchorages in structural strengthening
  • post-installed mechanical anchors
  • adhesive anchors and post-installed reinforcement
  • bond of special reinforcement in concrete
  • anchorages in special concretes
  • numerical modeling of anchorages and bond
  • code-based design models
  • performance-based approaches for anchorages
  • connections under seismic actions
  • connections under extreme situations (fire, impact)
  • connections under special actions.

Published Papers (11 papers)

Order results
Result details
Select all
Export citation of selected articles as:

Research

Jump to: Review

26 pages, 3742 KiB  
Article
Design Recommendations for Concrete Pryout Capacity of Headed Steel Studs and Post-Installed Anchors
by Khalil Jebara, Akanshu Sharma and Joško Ožbolt
CivilEng 2023, 4(3), 782-807; https://0-doi-org.brum.beds.ac.uk/10.3390/civileng4030044 - 10 Jul 2023
Viewed by 1596
Abstract
Current formulas to assess the shear capacity of headed steel stud anchors and post-installed (PI) anchors in case of pryout failure (sometimes known as pull-rear failure) have been derived either based on the indirect-tension resistance model or are fully empirical based on push-out [...] Read more.
Current formulas to assess the shear capacity of headed steel stud anchors and post-installed (PI) anchors in case of pryout failure (sometimes known as pull-rear failure) have been derived either based on the indirect-tension resistance model or are fully empirical based on push-out test results. In both cases, the predicted pryout capacity is clearly conservative and underestimates the true pryout capacity of anchorages, especially for stiff anchors with low embedment-to-diameter ratios (hef/d < 4.5). This paper proposes an empirical and a semi-empirical formula to predict the concrete pryout capacity of headed steel studs and PI anchors. They were derived based on an improved indirect-tension model which accounts for the stud diameter and the stud spacing in a group of anchors. Furthermore, a database of 214 monotonic shear tests from the literature, including own tests (push-off and horizontally shear tests), is reevaluated and compared to the provisions of EN1992-4. The scope of this assessment proposal includes single and group of headed steel studs and PI anchors attached to a stiff steel plate as well as shear connectors in composite structures without metal deck embedded in normal-weight concrete. Full article
(This article belongs to the Special Issue Connections in Concrete Volume 2)
Show Figures

Figure 1

14 pages, 2689 KiB  
Article
Effect of Internal Moisture and Outer Relative Humidity on Concrete Carbonation
by Charlotte Thiel, Johanna Kratzer, Benedikt Grimm, Thomas Kränkel and Christoph Gehlen
CivilEng 2022, 3(4), 1039-1052; https://0-doi-org.brum.beds.ac.uk/10.3390/civileng3040058 - 17 Nov 2022
Cited by 3 | Viewed by 1996
Abstract
With steadily rising CO2 concentrations in the ambient air and fast-changing concrete compositions with reduced clinker contents, the availability of reliable and accelerated concrete carbonation tests is of crucial importance to design durable structures. This paper focuses on the effects of moisture [...] Read more.
With steadily rising CO2 concentrations in the ambient air and fast-changing concrete compositions with reduced clinker contents, the availability of reliable and accelerated concrete carbonation tests is of crucial importance to design durable structures. This paper focuses on the effects of moisture under accelerated conditions and the effects of different CO2 exposure conditions. Mortar prisms incorporating three different cement types were cured and stored at either 50% or 65% relative humidity (RH). Afterwards, the prisms were carbonated at different ambient humidities (50, 57 and 65%), different CO2 concentrations (0.04, 1 and 3 vol.%) and complemented by a series of tests at increased gas pressure (2 barg). High-resolution test methods were used to explain the underlying carbonation mechanisms. The results show that pre-conditioning for two weeks—as currently suggested by the European Standard—seems to be too short because the initial inner moisture content severely affects the carbonation rate. Relative humidity during carbonation of 57% led to higher carbonation rates compared to 50% and 65%. In addition, climate data needs to be periodically (preferably permanently) recorded in research experiments and in laboratory testing to ensure fair interpretation of experimental results. Full article
(This article belongs to the Special Issue Connections in Concrete Volume 2)
Show Figures

Figure 1

11 pages, 3202 KiB  
Article
Utilizing Polypropylene Fiber in Sustainable Structural Concrete Mixtures
by Saman Hedjazi and Daniel Castillo
CivilEng 2022, 3(3), 562-572; https://0-doi-org.brum.beds.ac.uk/10.3390/civileng3030033 - 25 Jun 2022
Cited by 1 | Viewed by 2033
Abstract
Polypropylene fiber reinforced concrete (PFRC) is becoming more popular for structural purposes due to its durability, electrical resistivity, and mechanical properties. In this study, the influence of polypropylene fiber on the mechanical properties and ultrasonic pulse velocity (UPV) of fiber reinforced concrete (FRC) [...] Read more.
Polypropylene fiber reinforced concrete (PFRC) is becoming more popular for structural purposes due to its durability, electrical resistivity, and mechanical properties. In this study, the influence of polypropylene fiber on the mechanical properties and ultrasonic pulse velocity (UPV) of fiber reinforced concrete (FRC) were determined. Six different fiber volume fractions of polypropylene were considered in the experimental investigation with varying water–cement ratios and curing conditions. Non-destructive testing methods were utilized to determine the UPV of the PFRC. Available equations in literature for predicting the RFC’s compressive strength based on UPV values were selected. However, the computed values did not show good agreement with the compressive strengths obtained from the compression testing machine. It was confirmed that polypropylene fibers alter the propagation of UPV, and as a result, the existing equations do not accurately predict the compressive strength for PFRC. Therefore, a practical equation is proposed to accurately evaluate the compressive strength of PFRC with regard to UPV. Full article
(This article belongs to the Special Issue Connections in Concrete Volume 2)
Show Figures

Figure 1

22 pages, 9883 KiB  
Article
SC Wall-to-RC Basemat Over-Strength Connection: Behavior and Design
by Efe G. Kurt, Jungil Seo and Amit H. Varma
CivilEng 2022, 3(2), 503-524; https://0-doi-org.brum.beds.ac.uk/10.3390/civileng3020030 - 13 Jun 2022
Viewed by 2169
Abstract
This paper presents results from experimental and analytical investigations conducted to evaluate the lateral load behavior and capacity of steel-plate composite (SC) wall-to-reinforced concrete (RC) basemat connections. Two SC wall-to-reinforced concrete basemat connection specimens were tested. These SC wall specimens had a height-to-length [...] Read more.
This paper presents results from experimental and analytical investigations conducted to evaluate the lateral load behavior and capacity of steel-plate composite (SC) wall-to-reinforced concrete (RC) basemat connections. Two SC wall-to-reinforced concrete basemat connection specimens were tested. These SC wall specimens had a height-to-length ratio of 0.6 and did not include boundary elements. The experimental results include the lateral force-displacement (V-Δ) responses of the specimens and observations of local damage such as steel plate local buckling and concrete crushing. 3D finite element models were developed and benchmarked using the experimental results. The benchmarked models were used to conduct analytical parametric studies, expand the database, and gain additional insights into the behavior of SC wall-to-RC basemat connections. The parameters included in analytical investigations were the wall aspect ratio (h/lw), reinforcement ratio (ρ), and wall thickness (T). Full article
(This article belongs to the Special Issue Connections in Concrete Volume 2)
Show Figures

Figure 1

15 pages, 2953 KiB  
Article
Freeze-Thaw Behaviour of Post-Installed Bonded Anchors under Changing Climate Conditions
by Elisabeth Stierschneider, Oliver Zeman and Konrad Bergmeister
CivilEng 2022, 3(2), 332-346; https://0-doi-org.brum.beds.ac.uk/10.3390/civileng3020020 - 10 Apr 2022
Cited by 1 | Viewed by 2038
Abstract
The freeze-thaw behaviour of bonded fasteners in concrete is assessed according to the European Assessment Document 330499-01-0601 with freeze-thaw condition tests, which include 50 temperature cycles with a duration of 24 h between −20 °C and +20 °C on constantly loaded anchors. It [...] Read more.
The freeze-thaw behaviour of bonded fasteners in concrete is assessed according to the European Assessment Document 330499-01-0601 with freeze-thaw condition tests, which include 50 temperature cycles with a duration of 24 h between −20 °C and +20 °C on constantly loaded anchors. It is assumed that one cycle is equivalent to the temperature difference, which a bonded fastener undergoes in one year. Based on an analysis of a 28-year time series of air temperature data for Austria respecting the Alpine region, a modified test protocol with a temperature amplitude of 65 °C between −20 °C and +45 °C is compiled without a predefinition of the number of cycles, in order to simulate temperature differences that occur under real climatic conditions. The experimental test results obtained for both test procedures demonstrate that the stabilization of the displacements for the modified test series occurred after 185 temperature cycles, compared to the 50 cycles for the standard method. This means that an increase in the temperature amplitude of 25 °C in the higher temperature range leads to an approximately 3.5 times higher number of required temperature cycles until displacement stabilization is reached. It is concluded that the definition of the used temperature range for freeze-thaw testing in conjunction with climatic data should be critically considered, in order to possibly adapt pure freeze-thaw tests towards experiments that take into account real annual temperature differences. Full article
(This article belongs to the Special Issue Connections in Concrete Volume 2)
Show Figures

Figure 1

20 pages, 7593 KiB  
Article
Numerical and Experimental Investigation of Anchor Channels Subjected to Tension Load in Composite Slabs with Profiled Steel Decking
by Anton Bogdanić, Daniele Casucci and Joško Ožbolt
CivilEng 2022, 3(2), 296-315; https://0-doi-org.brum.beds.ac.uk/10.3390/civileng3020018 - 08 Apr 2022
Viewed by 3931
Abstract
In curtain wall applications, anchor channels are frequently installed near the edge of composite slabs with profiled steel decking. The complex concrete geometry of these floor slabs affects the capacity of all concrete failure modes, but there are currently no guidelines or investigations [...] Read more.
In curtain wall applications, anchor channels are frequently installed near the edge of composite slabs with profiled steel decking. The complex concrete geometry of these floor slabs affects the capacity of all concrete failure modes, but there are currently no guidelines or investigations available on this topic. The main objective of the present research is to investigate how the position of anchor channels and the complex slab geometry influence the tensile capacity of anchor channels. For this purpose, an extensive numerical parametric study was performed using the 3D nonlinear FE code MASA, which is based on the microplane constitutive model. In order to validate the numerical results, an experimental program was carried out for some of the configurations possible in practice. Based on the results, recommendations are given for the reduction in the tensile capacity of anchor channels in composite slabs with profiled steel decking. Full article
(This article belongs to the Special Issue Connections in Concrete Volume 2)
Show Figures

Figure 1

12 pages, 3188 KiB  
Article
Assessment of Quality of Fresh Concrete Delivered at Varying Temperatures
by Maroua Saidi, Kazem Jadidi and Moses Karakouzian
CivilEng 2022, 3(1), 135-146; https://0-doi-org.brum.beds.ac.uk/10.3390/civileng3010009 - 12 Feb 2022
Cited by 1 | Viewed by 4473
Abstract
Concrete is increasingly utilized in the construction field in Southern Nevada. This area has an arid and hot summer and freezing cold winter conditions. These extreme conditions affect the properties of fresh concrete, which can cause cracking. Hot weather conditions may adversely affect [...] Read more.
Concrete is increasingly utilized in the construction field in Southern Nevada. This area has an arid and hot summer and freezing cold winter conditions. These extreme conditions affect the properties of fresh concrete, which can cause cracking. Hot weather conditions may adversely affect both fresh and hardened concrete properties. Even though practices can minimize the detrimental effects, good quality control of fresh concrete, from mixing to finishing, is crucial under hot weather conditions. The objective of the present study is to evaluate the seasonal consistency of concrete quality, considering strength and slump properties. Another objective of this research is to determine the relationship between the seasonal air temperature variations and those of freshly batched concrete. Results indicate that strength and slump remain constant with varying air and concrete temperatures during pour. Additionally, during the hot season (air temperature above 27 °C (80 °F)), fresh concrete’s temperature is lower than the air’s temperature, in contrast during the cold season (air temperature below 16 °C (60 °F)), fresh concrete’s temperature is higher than the air’s temperature. Fresh concrete temperature and air temperature are similar in the range of 60 to 80 °F. Therefore, to limit the use of additional water or admixtures it is recommended to pour concrete when the air temperature is in the range of 16° and 27 °C (60 to 80 °F). Full article
(This article belongs to the Special Issue Connections in Concrete Volume 2)
Show Figures

Figure 1

15 pages, 2203 KiB  
Article
Concrete Overstrength: Assessment of Field Strength Seeking Insights for Overdesign Optimization
by Rodrigo Antunes
CivilEng 2022, 3(1), 51-65; https://0-doi-org.brum.beds.ac.uk/10.3390/civileng3010004 - 10 Jan 2022
Cited by 1 | Viewed by 4085
Abstract
This study investigates the high contents of cementitious materials in Portland cement concrete and assesses the required (f’cr) and actual (σ) compressive strength of concrete specimens. A linear optimization technique identifies the required binder content to reach f’ [...] Read more.
This study investigates the high contents of cementitious materials in Portland cement concrete and assesses the required (f’cr) and actual (σ) compressive strength of concrete specimens. A linear optimization technique identifies the required binder content to reach f’cr. Standard specifications have required concrete overdesign (OD) for decades, but few studies have evaluated the actual magnitude of OD from field data. The compressive strength of 958 cylinders prepared in the field represented 8200 m3 of ready-mixed concrete with 300 and 450 kg/m3 of cementitious are analyzed. The actual OD appears to be 7 to 21% higher than required. The required 28-day compressive strength of concrete was achieved in less than seven days. Therefore, the content of the cementitious materials could be reduced by 6 and 17% so that concrete could reach f’cr without cementitious overconsumption. Reducing cementitious content is recommended to improve construction quality and optimize resource utilization. Among the main reasons for this recommendation are the estimated substantial long-term savings, increased concrete durability and more rational use of natural resources required to build the structures. Full article
(This article belongs to the Special Issue Connections in Concrete Volume 2)
Show Figures

Figure 1

20 pages, 13232 KiB  
Article
Numerical Investigations on Non-Rectangular Anchor Groups under Shear Loads Applied Perpendicular or Parallel to an Edge
by Boglárka Bokor and Akanshu Sharma
CivilEng 2021, 2(3), 692-711; https://0-doi-org.brum.beds.ac.uk/10.3390/civileng2030038 - 28 Aug 2021
Cited by 5 | Viewed by 2813
Abstract
Anchorages of non-rectangular configuration, though not covered by current design codes, are often used in practice due to functional or architectural needs. Frequently, such anchor groups are placed close to a concrete edge and are subjected to shear loads. The design of such [...] Read more.
Anchorages of non-rectangular configuration, though not covered by current design codes, are often used in practice due to functional or architectural needs. Frequently, such anchor groups are placed close to a concrete edge and are subjected to shear loads. The design of such anchorages requires engineering judgement and no clear rules are given in the codes and standards. In this work, numerical investigations using a nonlinear 3D FE analysis code are carried out on anchor groups with triangular and hexagonal anchor patterns to understand their behavior under shear loads. A microplane model with relaxed kinematic constraint is utilized as the constitutive law for concrete. Two different orientations are considered for both triangular and hexagonal anchor groups while no hole clearance is considered in the analysis. Two loading scenarios are investigated: (i) shear loading applied perpendicular and towards the edge; and (ii) shear loading applied parallel to the edge. The results of the analyses are evaluated in terms of the load-displacement behavior and failure modes. A comparison is made between the results of the numerical simulations and the analytical calculations according to the current approaches. It is found that, similar to the rectangular anchorages, and also for such non-rectangular anchorages without hole clearance, it may be reasonable to calculate the concrete edge breakout capacity by assuming a failure crack from the back anchor row. Furthermore, the failure load of the investigated groups loaded in shear parallel to the edge may be considered as twice the failure load of the corresponding groups loaded in shear perpendicular to the edge. Full article
(This article belongs to the Special Issue Connections in Concrete Volume 2)
Show Figures

Figure 1

Review

Jump to: Research

14 pages, 484 KiB  
Review
Experimental Evaluation of Post-Earthquake Fire on Reinforced Concrete Structures—A Review
by Vahid Khiali and Hugo Rodrigues
CivilEng 2023, 4(2), 469-482; https://0-doi-org.brum.beds.ac.uk/10.3390/civileng4020027 - 26 Apr 2023
Viewed by 1573
Abstract
This review aims to investigate the recent advancements in the performance of earthquake-damaged reinforced concrete structures subjected to fire loading and the damages that are induced by fire to reinforced concrete structural elements with damage due to seismic loads. The first part of [...] Read more.
This review aims to investigate the recent advancements in the performance of earthquake-damaged reinforced concrete structures subjected to fire loading and the damages that are induced by fire to reinforced concrete structural elements with damage due to seismic loads. The first part of the paper provides a general understanding of the Post-Earthquake Fire (PEF) effect on reinforced concrete structures, and some statistics regarding the previous earthquake casualties and amounts of destruction in different regions of the world are addressed. In the second part of the investigation, an in-depth review of the experimental and numerical procedures of PEF analysis in concrete columns, beams, slabs, and full-scale RC frames and the types of damages in RC members due to PEF have been presented, giving a general review of the results and conclusions in previous research in PEF in different reinforced concrete structures. In the end is discussed the concept of hybrid fire simulation, its applications in engineering problems, the methodologies that consider full interaction effects as well as recent breakthroughs in studying PEF using Real-Time Hybrid Simulation. Full article
(This article belongs to the Special Issue Connections in Concrete Volume 2)
Show Figures

Figure 1

13 pages, 308 KiB  
Review
Carbonation Potential of Cementitious Structures in Service and Post-Demolition: A Review
by Cinthia Maia Pederneiras, Catarina Brazão Farinha and Rosário Veiga
CivilEng 2022, 3(2), 211-223; https://0-doi-org.brum.beds.ac.uk/10.3390/civileng3020013 - 23 Mar 2022
Cited by 6 | Viewed by 3043
Abstract
The construction sector is responsible for a great environmental impact. The cement industry, which is included in this sector, emits about 650 to 800 kg of CO2 per each tonne of cement produced, being one of the most polluting industries in terms [...] Read more.
The construction sector is responsible for a great environmental impact. The cement industry, which is included in this sector, emits about 650 to 800 kg of CO2 per each tonne of cement produced, being one of the most polluting industries in terms of greenhouse gas emissions. The cement manufacturing process releases about 7% of the total worldwide CO2 emissions. However, concrete and cement-based materials present CO2 uptake potential during their service life and post-demolition through carbonation processes. The carbonation reactions rate depends on several factors, namely type and content of cement, porosity of concrete, temperature, relative humidity and exposure conditions area. Therefore, to estimate the CO2 capture of concrete during its life cycle is not a straightforward calculation. Some studies have been developed using different methodologies in order to evaluate the CO2 potential of cementitious elements in service and post-demolition. This paper reviews the documented approaches that quantify the CO2 uptake of concrete over time, summarizing the assumptions adopted for each previous work. Overall, it was concluded that part of the CO2 emissions released during cement production are reabsorbed by concrete products during their life cycle, which partially offsets the environmental impact and reduces the CO2 footprint of the cement industry. Full article
(This article belongs to the Special Issue Connections in Concrete Volume 2)
Back to TopTop