Catheter Ablation of Cardiac Arrhythmias: Practices and Outcomes

A special issue of Journal of Cardiovascular Development and Disease (ISSN 2308-3425). This special issue belongs to the section "Electrophysiology and Cardiovascular Physiology".

Deadline for manuscript submissions: closed (28 February 2023) | Viewed by 69105

Special Issue Editor


E-Mail Website
Guest Editor
1. Cardioangiologisches Centrum Bethanien (CCB), Kardiologie, Medizinische Klinik III, Agaplesion Markus Krankenhaus, Akademisches Lehrkrankenhaus der Goethe-Universität Frankfurt am Main, 60431 Frankfurt am Main, Germany
2. Doctor of Medicine, Universität zu Lübeck, 23562 Lübeck, Germany
Interests: general cardiology; arrhythmias; electrophysiology/catheter ablation (EHRA/ESC certificate); hypertension; renal denervation; coronary heart disease; intervention; heart failure; (transösophageal) echocardiography; atrial fibrillation; stroke; sudden cardiac death; clinical trial; evidence based medicine
Special Issues, Collections and Topics in MDPI journals

Special Issue Information

Dear Colleagues, 

Catheter ablation is an effective treatment option for cardiac arrhythmia. For decades, there has been remarkable advancement in techniques and technologies for mapping and ablation, helping clinicians to further understand the mechanisms of arrhythmias, to facilitate the procedures, and to improve the safety of the ablation and patients’ clinical outcome. The aim and scope of this Special Issue mainly focus on but are not limited to current mapping and ablation techniques for arrhythmias, procedural endpoints and outcomes, procedural complications, and prevention strategies. We welcome original research articles, systematic reviews, state-of-the-art reviews, challenging/informative case series, challenging/informative images in mapping and ablation, new technologies, etc. 

Dr. Shaojie Chen
Guest Editor

Manuscript Submission Information

Manuscripts should be submitted online at www.mdpi.com by registering and logging in to this website. Once you are registered, click here to go to the submission form. Manuscripts can be submitted until the deadline. All submissions that pass pre-check are peer-reviewed. Accepted papers will be published continuously in the journal (as soon as accepted) and will be listed together on the special issue website. Research articles, review articles as well as short communications are invited. For planned papers, a title and short abstract (about 100 words) can be sent to the Editorial Office for announcement on this website.

Submitted manuscripts should not have been published previously, nor be under consideration for publication elsewhere (except conference proceedings papers). All manuscripts are thoroughly refereed through a single-blind peer-review process. A guide for authors and other relevant information for submission of manuscripts is available on the Instructions for Authors page. Journal of Cardiovascular Development and Disease is an international peer-reviewed open access monthly journal published by MDPI.

Please visit the Instructions for Authors page before submitting a manuscript. The Article Processing Charge (APC) for publication in this open access journal is 2700 CHF (Swiss Francs). Submitted papers should be well formatted and use good English. Authors may use MDPI's English editing service prior to publication or during author revisions.

Keywords

  • ablation
  • arrhythmia
  • electrophysiology
  • atrial fibrillation
  • atrial flutter
  • atrial tachycardia
  • mapping
  • supraventricular tachycardia
  • ventricular arrhythmia

Published Papers (33 papers)

Order results
Result details
Select all
Export citation of selected articles as:

Research

Jump to: Review, Other

11 pages, 1360 KiB  
Article
Clinical Impact of Cardiac Fibrosis on Arrhythmia Recurrence after Ablation in Adults with Congenital Heart Disease
by Francesco Perna, Alessandro Telesca, Roberto Scacciavillani, Maria Lucia Narducci, Gianluigi Bencardino, Gaetano Pinnacchio, Francesco Raffaele Spera, Rocco Sabarese, Gianluca Comerci and Gemma Pelargonio
J. Cardiovasc. Dev. Dis. 2023, 10(4), 168; https://0-doi-org.brum.beds.ac.uk/10.3390/jcdd10040168 - 13 Apr 2023
Cited by 1 | Viewed by 1680
Abstract
Background. Adults with congenital heart disease (ACHD) are often affected by cardiac arrhythmias requiring catheter ablation. Catheter ablation in this setting represents the treatment of choice but is flawed by frequent recurrencies. Predictors of arrhythmia relapse have been identified, but the role of [...] Read more.
Background. Adults with congenital heart disease (ACHD) are often affected by cardiac arrhythmias requiring catheter ablation. Catheter ablation in this setting represents the treatment of choice but is flawed by frequent recurrencies. Predictors of arrhythmia relapse have been identified, but the role of cardiac fibrosis in this setting has not been investigated. The aim of this study was to determine the role of the extension of cardiac fibrosis, detected by electroanatomical mapping, in predicting arrhythmia recurrencies after ablation in ACHD. Materials and Methods. Consecutive patients with congenital heart disease and atrial or ventricular arrhythmias undergoing catheter ablation were enrolled. An electroanatomical bipolar voltage map was performed during sinus rhythm in each patient and bipolar scar was assessed according to the current literature data. During follow-up, arrhythmia recurrences were recorded. The relationship between the extent of myocardial fibrosis and arrhythmia recurrence was assessed. Results. Twenty patients underwent successful catheter ablation of atrial (14) or ventricular (6) arrhythmias, with no inducible arrhythmia at the end of the procedure. During a median follow-up period of 207 weeks (IQR 80 weeks), eight patients (40%; five atrial and three ventricular arrhythmias) had arrhythmia recurrence. Of the five patients undergoing a second ablation, four showed a new reentrant circuit, while one patient had a conduction gap across a previous ablation line. The extension of the bipolar scar area (HR 1.049, CI 1.011–1.089, p = 0.011) and the presence of a bipolar scar area >20 cm2 (HR 6.101, CI 1.147–32.442, p = 0.034) were identified as predictors of arrhythmia relapse. Conclusion. The extension of the bipolar scar area and the presence of a bipolar scar area >20 cm2 can predict arrhythmia relapse in ACHD undergoing catheter ablation of atrial and ventricular arrhythmias. Recurrent arrhythmias are often caused by circuits other than those previously ablated. Full article
(This article belongs to the Special Issue Catheter Ablation of Cardiac Arrhythmias: Practices and Outcomes)
Show Figures

Figure 1

11 pages, 1387 KiB  
Article
Long-Term Renal Function after Catheter Ablation of Atrial Fibrillation
by Vladan Kovačević, Milan M. Marinković, Aleksandar Kocijančić, Nikola Isailović, Jelena Simić, Miroslav Mihajlović, Vera Vučićević, Tatjana S. Potpara and Nebojša M. Mujović
J. Cardiovasc. Dev. Dis. 2023, 10(4), 151; https://0-doi-org.brum.beds.ac.uk/10.3390/jcdd10040151 - 31 Mar 2023
Cited by 1 | Viewed by 1829
Abstract
Background: Atrial fibrillation (AF) is associated with the development and progression of chronic kidney disease (CKD). This study evaluated the impact of long-term rhythm outcome after catheter ablation (CA) of AF on renal function. Methods and results: The study group included 169 consecutive [...] Read more.
Background: Atrial fibrillation (AF) is associated with the development and progression of chronic kidney disease (CKD). This study evaluated the impact of long-term rhythm outcome after catheter ablation (CA) of AF on renal function. Methods and results: The study group included 169 consecutive patients (the mean age was 59.6 ± 10.1 years, 61.5% were males) who underwent their first CA of AF. Renal function was assessed by eGFR (using the CKD-EPI and MDRD formulas), and by creatinine clearance (using the Cockcroft–Gault formula) in each patient before and 5 years after index CA procedure. During the 5-year follow-up after CA, the late recurrence of atrial arrhythmia (LRAA) was documented in 62 patients (36.7%). The mean eGFR, regardless of which formula was used, significantly decreased at 5 years following CA in patients with LRAA (all p < 0.05). In the arrhythmia-free patients, the mean eGFR at 5 years post-CA remained stable (for the CKD-EPI formula: 78.7 ± 17.3 vs. 79.4 ± 17.4, p = 0.555) or even significantly improved (for the MDRD formula: 74.1 ± 17.0 vs. 77.4 ± 19.6, p = 0.029) compared with the baseline. In the multivariable analysis, the independent risk factors for rapid CKD progression (decline in eGFR > 5 mL/min/1.73 m2 per year) were the post-ablation LRAA occurrence (hazard ratio 3.36 [95% CI: 1.25–9.06], p = 0.016), female sex (3.05 [1.13–8.20], p = 0.027), vitamin K antagonists (3.32 [1.28–8.58], p = 0.013), or mineralocorticoid receptor antagonists’ use (3.28 [1.13–9.54], p = 0.029) after CA. Conclusions: LRAA after CA is associated with a significant decrease in eGFR, and it is an independent risk factor for rapid CKD progression. Conversely, eGFR in arrhythmia-free patients after CA remained stable or even improved significantly. Full article
(This article belongs to the Special Issue Catheter Ablation of Cardiac Arrhythmias: Practices and Outcomes)
Show Figures

Figure 1

12 pages, 3330 KiB  
Article
A Pilot Trial to Compare the Long-Term Efficacy of Pulmonary Vein Isolation with High-Power Short-Duration Radiofrequency Versus Laser Energy with Rapid Ablation Mode
by Sönke Schildt, Sabine Fredersdorf, Carsten G. Jungbauer, Christian Hauck, Daniel Tarnowski, Kurt Debl, Stefan Neef, Christian Schach, Samuel Sossalla, Lars S. Maier and Ekrem Üçer
J. Cardiovasc. Dev. Dis. 2023, 10(3), 98; https://0-doi-org.brum.beds.ac.uk/10.3390/jcdd10030098 - 23 Feb 2023
Viewed by 1422
Abstract
Background: Pulmonary vein (PV) reconnection is the major cause of atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI). The probability of reconnection is higher if the primary lesion is not sufficiently effective, which can be unmasked with an adenosine provocation test (APT). [...] Read more.
Background: Pulmonary vein (PV) reconnection is the major cause of atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI). The probability of reconnection is higher if the primary lesion is not sufficiently effective, which can be unmasked with an adenosine provocation test (APT). High-power short-duration radiofrequency energy (HPSD) guided with ablation index (AI) and the third generation of the visually guided laser balloon (VGLB) are new methods for PVI. Methods: A total of 70 participants (35 in each group) who underwent a PVI with either AI-guided HPSD (50 W; AI 500 for the anterior and 400 for the posterior wall, respectively) or VGLB ablation were included in this observational pilot trial. Twenty minutes after each PVI, an APT was performed. The primary endpoint was the event-free survival from AF after three years. Results: A total of 137 (100%) PVs in the HPSD arm and 131 PVs (98.5%) in the VGLB arm were initially successfully isolated (p = 0.24). The overall procedure duration was similar in both arms (155 ± 39 in HPSD vs. 175 ± 58 min in VGLB, p = 0.191). Fluoroscopy time, left atrial dwelling time and duration from the first to the last ablation were longer in the VGLB arm (23 ± 8 vs. 12 ± 3 min, p < 0.001; 157 (111–185) vs. 134 (104–154) min, p = 0.049; 92(59–108) vs. 72 (43–85) min, p = 0.010). A total of 127 (93%) in the HPSD arm and 126 (95%) PVs in the VGLB arm remained isolated after APT (p = 0.34). The primary endpoint was met 1107 ± 68 days after ablation in 71% vs. 66% in the VGLB and HPSD arms, respectively (p = 0.65). Conclusions: HPSD and VGLB did not differ with respect to long-term outcome of PVI. A large, randomized study should be conducted to compare clinical outcomes with respect to these new ablation techniques. Full article
(This article belongs to the Special Issue Catheter Ablation of Cardiac Arrhythmias: Practices and Outcomes)
Show Figures

Figure 1

22 pages, 10773 KiB  
Article
Comparative Analysis of Temperature Rise between Convective Heat Transfer Method and Computational Fluid Dynamics Method in an Anatomy-Based Left Atrium Model during Pulsed Field Ablation: A Computational Study
by Lianru Zang, Kaihao Gu, Xingkai Ji, Hao Zhang, Shengjie Yan and Xiaomei Wu
J. Cardiovasc. Dev. Dis. 2023, 10(2), 56; https://0-doi-org.brum.beds.ac.uk/10.3390/jcdd10020056 - 30 Jan 2023
Cited by 1 | Viewed by 1460
Abstract
The non-thermal effects are considered one of the prominent advantages of pulsed field ablation (PFA). However, at higher PFA doses, the temperature rise in the tissue during PFA may exceed the thermal damage threshold, at which time intracardiac pulsatile blood flow plays a [...] Read more.
The non-thermal effects are considered one of the prominent advantages of pulsed field ablation (PFA). However, at higher PFA doses, the temperature rise in the tissue during PFA may exceed the thermal damage threshold, at which time intracardiac pulsatile blood flow plays a crucial role in suppressing this temperature rise. This study aims to compare the effect of heat dissipation of the different methods in simulating the pulsatile blood flow during PFA. This study first constructed an anatomy-based left atrium (LA) model and then applied the convective heat transfer (CHT) method and the computational fluid dynamics (CFD) method to the model, respectively, and the thermal convective coefficients used in the CHT method are 984 (W/m2*K) (blood-myocardium interface) and 4372 (W/m2*K) (blood–catheter interface), respectively. Then, it compared the effect of the above two methods on the maximum temperature of myocardium and blood, as well as the myocardial ablation volumes caused by irreversible electroporation (IRE) and hyperthermia under different PFA parameters. Compared with the CFD method, the CHT method underestimates the maximum temperature of myocardium and blood; the differences in the maximum temperature of myocardium and blood between the two methods at the end of the last pulse are significant (>1 °C), and the differences in the maximum temperature of blood at the end of the last pulse interval are significant (>1 °C) only at a pulse amplitude greater than 1000 V or pulse number greater than 10. Under the same pulse amplitude and different heat dissipation methods, the IRE ablation volumes are the same. Compared with the CFD method, the CHT method underestimates the hyperthermia ablation volume; the differences in the hyperthermia ablation volume are significant (>1 mm3) only at a pulse amplitude greater than 1000 V, a pulse interval of 250 ms, or a pulse number greater than 10. Additionally, the hyperthermia ablation isosurfaces are completely wrapped by the IRE ablation isosurfaces in the myocardium. Thus, during PFA, compared with the CFD method, the CHT method cannot accurately simulate the maximum myocardial temperature; however, except at the above PFA parameters, the CHT method can accurately simulate the maximum blood temperature and the myocardial ablation volume caused by IRE and hyperthermia. Additionally, within the range of the PFA parameters used in this study, the temperature rise during PFA may not lead to the appearance of additional hyperthermia ablation areas beyond the IRE ablation area in the myocardium. Full article
(This article belongs to the Special Issue Catheter Ablation of Cardiac Arrhythmias: Practices and Outcomes)
Show Figures

Figure 1

11 pages, 3058 KiB  
Article
In Silico Modelling to Assess the Electrical and Thermal Disturbance Provoked by a Metal Intracoronary Stent during Epicardial Pulsed Electric Field Ablation
by Ana González-Suárez, Juan J. Pérez, Barry O’Brien and Adnan Elahi
J. Cardiovasc. Dev. Dis. 2022, 9(12), 458; https://0-doi-org.brum.beds.ac.uk/10.3390/jcdd9120458 - 14 Dec 2022
Cited by 4 | Viewed by 1382
Abstract
Background: Pulsed Electric Field (PEF) ablation has been recently proposed to ablate cardiac ganglionic plexi (GP) aimed to treat atrial fibrillation. The effect of metal intracoronary stents in the vicinity of the ablation electrode has not been yet assessed. Methods: A 2D numerical [...] Read more.
Background: Pulsed Electric Field (PEF) ablation has been recently proposed to ablate cardiac ganglionic plexi (GP) aimed to treat atrial fibrillation. The effect of metal intracoronary stents in the vicinity of the ablation electrode has not been yet assessed. Methods: A 2D numerical model was developed accounting for the different tissues involved in PEF ablation with an irrigated ablation device. A coronary artery (with and without a metal intracoronary stent) was considered near the ablation source (0.25 and 1 mm separation). The 1000 V/cm threshold was used to estimate the ‘PEF-zone’. Results: The presence of the coronary artery (with or without stent) distorts the E-field distribution, creating hot spots (higher E-field values) in the front and rear of the artery, and cold spots (lower E-field values) on the sides of the artery. The value of the E-field inside the coronary artery is very low (~200 V/cm), and almost zero with a metal stent. Despite this distortion, the PEF-zone contour is almost identical with and without artery/stent, remaining almost completely confined within the fat layer in any case. The mentioned hot spots of E-field translate into a moderate temperature increase (<48 °C) in the area between the artery and electrode. These thermal side effects are similar for pulse intervals of 10 and 100 μs. Conclusions: The presence of a metal intracoronary stent near the ablation device during PEF ablation simply ‘amplifies’ the E-field distortion already caused by the presence of the vessel. This distortion may involve moderate heating (<48 °C) in the tissue between the artery and ablation electrode without associated thermal damage. Full article
(This article belongs to the Special Issue Catheter Ablation of Cardiac Arrhythmias: Practices and Outcomes)
Show Figures

Figure 1

13 pages, 1457 KiB  
Article
Healthcare Utilization and Outcomes in Atrial Fibrillation Patients Treated by Drug Therapy versus a Catheter Ablation Strategy—A Middle European Propensity Score Matched Cohort Study
by Martin Martinek, Harry J. G. M. Crijns, Barbara A. B. Essers, Rene Wiesinger and Gerald Pruckner
J. Cardiovasc. Dev. Dis. 2022, 9(12), 451; https://0-doi-org.brum.beds.ac.uk/10.3390/jcdd9120451 - 10 Dec 2022
Viewed by 1216
Abstract
Background and Aims: Atrial fibrillation (AF) is the most prevalent arrhythmia, associated with increased mortality and morbidity and causing relevant costs. Treatment options consist of catheter ablation (PVI) and rate or rhythm control drugs (non-PVI). Methods: We analyze inpatient and outpatient data from [...] Read more.
Background and Aims: Atrial fibrillation (AF) is the most prevalent arrhythmia, associated with increased mortality and morbidity and causing relevant costs. Treatment options consist of catheter ablation (PVI) and rate or rhythm control drugs (non-PVI). Methods: We analyze inpatient and outpatient data from the Upper Austrian Health Insurance Fund. Data of patients with a first hospitalization for AF in the years 2005 to 2018 were examined, using propensity score matching (PSM) including all CHA2DS2-VASc variables and working “collar”. Results: Out of 21,791 AF patients, PSM identified 1013 well-matching pairs (PVI and non-PVI). Over a ten-year period, the PVI treatment strategy group reveals significantly higher inpatient and outpatient expenditures (€2200/year). Positive economic effects can be demonstrated by a 5.1 percentage points (pp) higher employment rate and fewer retirements (7.6pp). Of utmost important is the 5.8pp all-cause mortality reduction over 10 years in the PVI treatment strategy. Conclusions: A PVI based treatment strategy results in higher healthcare expenditures vs. drug therapy alone. Most of these higher costs were caused by the PVI procedures during this period. Thus, more effective and efficient methods are needed to further reduce costs for the intervention and prevent repeat procedures. The benefit of a PVI treatment strategy is seen in higher employment rates, which are crucial from a societal perspective and should be a strong argument for caregivers. We show a significant reduction in all-cause mortality, which we partly attribute to the PVI procedure itself, to a stricter risk factor assessment and treatment, and a tighter medical adherence. Full article
(This article belongs to the Special Issue Catheter Ablation of Cardiac Arrhythmias: Practices and Outcomes)
Show Figures

Figure 1

12 pages, 5422 KiB  
Article
Limitations of Baseline Impedance, Impedance Drop and Current for Radiofrequency Catheter Ablation Monitoring: Insights from In silico Modeling
by Ramiro M. Irastorza, Timothy Maher, Michael Barkagan, Rokas Liubasuskas, Juan J. Pérez, Enrique Berjano and Andre d’Avila
J. Cardiovasc. Dev. Dis. 2022, 9(10), 336; https://0-doi-org.brum.beds.ac.uk/10.3390/jcdd9100336 - 03 Oct 2022
Cited by 3 | Viewed by 1882
Abstract
Background: Baseline impedance, radiofrequency current, and impedance drop during radiofrequency catheter ablation are thought to predict effective lesion formation. However, quantifying the contributions of local versus remote impedances provides insights into the limitations of indices using those parameters. Methods: An in silico model [...] Read more.
Background: Baseline impedance, radiofrequency current, and impedance drop during radiofrequency catheter ablation are thought to predict effective lesion formation. However, quantifying the contributions of local versus remote impedances provides insights into the limitations of indices using those parameters. Methods: An in silico model of left atrial radiofrequency catheter ablation was used based on human thoracic measurements and solved for (1) initial impedance (Z), (2) percentage of radiofrequency power delivered to the myocardium and blood (3) total radiofrequency current, (4) impedance drop during heating, and (5) lesion size after a 25 W–30 s ablation. Remote impedance was modeled by varying the mixing ratio between skeletal muscle and fat. Local impedance was modeled by varying insertion depth of the electrode (ID). Results: Increasing the remote impedance led to increased baseline impedance, lower system current delivery, and reduced lesion size. For ID = 0.5 mm, Z ranged from 115 to 132 Ω when fat percentage varied from 20 to 80%, resulting in a decrease in the RF current from 472 to 347 mA and a slight decrease in lesion size from 5.6 to 5.1 mm in depth, and from 9.2 to 8.0 mm in maximum width. In contrast, increasing the local impedance led to lower system current but larger lesions. For a 50% fat–muscle mixture, Z ranged from 118 to 138 Ω when ID varied from 0.3 to 1.9 mm, resulting in a decrease in the RF current from 463 to 443 mA and an increase in lesion size, from 5.2 up to 7.5 mm in depth, and from 8.4 up to 11.6 mm in maximum width. In cases of nearly identical Z but different contributions of local and remote impedance, markedly different lesions sizes were observed despite only small differences in RF current. Impedance drop better predicted lesion size (R2 > 0.93) than RF current (R2 < 0.1). Conclusions: Identical baseline impedances and observed RF currents can lead to markedly different lesion sizes with different relative contributions of local and remote impedances to the electrical circuit. These results provide mechanistic insights into the advantage of measuring local impedance and identifies potential limitations of indices incorporating baseline impedance or current to predict lesion quality. Full article
(This article belongs to the Special Issue Catheter Ablation of Cardiac Arrhythmias: Practices and Outcomes)
Show Figures

Figure 1

12 pages, 2990 KiB  
Article
Evaluation of Isolation Area, Myocardial Injury and Left Atrial Function Following High-Power Short-Duration Radiofrequency or Second-Generation Cryoballoon Ablation for Atrial Fibrillation
by Krisztian Istvan Kassa, Zsofia Nagy, Daniel Simkovits, Zsuzsanna Kis, Tamas Ferenci, Zoltan Som, Csaba Foldesi and Attila Kardos
J. Cardiovasc. Dev. Dis. 2022, 9(10), 327; https://0-doi-org.brum.beds.ac.uk/10.3390/jcdd9100327 - 28 Sep 2022
Cited by 1 | Viewed by 1588
Abstract
This randomized study aims to compare the left atrial (LA) lesion size, function, and tissue damage following pulmonary vein isolation (PVI) by high-power short-duration (HPSD) radiofrequency (RF) and second-generation cryoballoon (CB2) ablation. We enrolled 40 patients with paroxysmal atrial fibrillation who underwent PVI [...] Read more.
This randomized study aims to compare the left atrial (LA) lesion size, function, and tissue damage following pulmonary vein isolation (PVI) by high-power short-duration (HPSD) radiofrequency (RF) and second-generation cryoballoon (CB2) ablation. We enrolled 40 patients with paroxysmal atrial fibrillation who underwent PVI by HPSD RF (n = 21) or CB2 (n = 19). Every patient underwent LA CT angiography and transthoracic echocardiography (TTE) to assess the LA anatomy and function. Biomarker levels (hs-cTnT, hs-CRP, LDH) were compared pre- and post-procedurally. Pre- and post-ablation high-density mapping (HDM) was performed. The isolation area was defined under 0.2 mV bipolar voltage (low voltage area, LVA). We calculated the post-PVI LVA/LA surface ratio using LA CT-HDM merge images. At 3-month follow-up, TTE was performed to assess the changes in LA function. Post-ablation hs-cTnT level was significantly higher in the RF group (RF: 1249 ± 469 ng/L, CB2: 995 ± 280 ng/L, p = 0.024). Post-PVI hs-CRP (RF: 9.53 ± 10.30 mg/L, CB2: 12.36 ± 5.76 mg/L, p = 0.034) and LDH levels (RF: 349.9 ± 65.6 U/L, CB2: 451.6 ± 91.3 U/L, p < 0.001) were significantly higher following CB2 ablation. Post-PVI LVA/LA surface ratios were 8.37 ± 6.42% in the RF group and 13.58 ± 8.92% in the CB2 group (p = 0.022). LA function did not change significantly after the PVI procedure. Our data indicate that second-generation cryoballoon ablation produces a significantly larger LA lesion size compared to “point-by-point” HPSD radiofrequency. Both techniques preserve LA function. The myocardial component of tissue loss appears to be higher using HPSD radiofrequency ablation, with less collateral damage. Full article
(This article belongs to the Special Issue Catheter Ablation of Cardiac Arrhythmias: Practices and Outcomes)
Show Figures

Figure 1

22 pages, 16517 KiB  
Article
Effect of Anisotropic Electrical Conductivity Induced by Fiber Orientation on Ablation Characteristics of Pulsed Field Ablation in Atrial Fibrillation Treatment: A Computational Study
by Lianru Zang, Kaihao Gu, Xingkai Ji, Hao Zhang, Shengjie Yan and Xiaomei Wu
J. Cardiovasc. Dev. Dis. 2022, 9(10), 319; https://0-doi-org.brum.beds.ac.uk/10.3390/jcdd9100319 - 22 Sep 2022
Cited by 4 | Viewed by 1550
Abstract
Pulsed field ablation (PFA) is a promising new ablation modality for the treatment of atrial fibrillation (AF); however, the effect of fiber orientation on the ablation characteristics of PFA in AF treatment is still unclear, which is likely an essential factor in influencing [...] Read more.
Pulsed field ablation (PFA) is a promising new ablation modality for the treatment of atrial fibrillation (AF); however, the effect of fiber orientation on the ablation characteristics of PFA in AF treatment is still unclear, which is likely an essential factor in influencing the ablation characteristics. This study constructed an anatomy-based left atrium (LA) model incorporating fiber orientation and selected various electrical conductivity and ablation targets to investigate the effect of anisotropic electrical conductivity (AC), compared with isotropic electrical conductivity (IC), on the ablation characteristics of PFA in AF treatment. The results show that the percentage differences in the size of the surface ablation area between AC and IC are greater than 73.71%; the maximum difference in the size of the ablation isosurface between AC and IC at different locations in the atrial wall is 3.65 mm (X-axis), 3.65 mm (Z-axis), and 4.03 mm (X-axis), respectively; and the percentage differences in the size of the ablation volume are greater than 6.9%. Under the condition of the pulse, the amplitude is 1000 V, the total PFA duration is 1 s, and the pulse train interval is 198.4 ms; the differences in the temperature increase between AC and IC in LA are less than 2.46 °C. Hence, this study suggests that in further exploration of the computational study of PFA in AF treatment using the same or similar conditions as those used here (myocardial electrical conductivity, pulse parameters, and electric field intensity damage threshold), to obtain more accurate computational results, it is necessary to adopt AC rather than IC to investigate the size of the surface ablation area, the size of the ablation isosurface, or the size of the ablation volume generated by PFA in LA. Moreover, if only investigating the temperature increase generated by PFA in LA, adopting IC instead of AC for simplifying the model construction process is reasonable. Full article
(This article belongs to the Special Issue Catheter Ablation of Cardiac Arrhythmias: Practices and Outcomes)
Show Figures

Figure 1

10 pages, 1400 KiB  
Article
Incidence of Long-Term Pulmonary Vein Reconnection after a 2-Minute Cryoballoon Freeze for Pulmonary Vein Isolation—Invasive Insights of TTI-Dependent Cryoenergy Titration
by Alexander Pott, Michael Baumhardt, Mohammad Al-Masalmeh, Alexander Wolf, Matthias Schiele, Christiane Schweizer, Carlo Bothner, Deniz Aktolga, Yannick Teumer, Karolina Weinmann, Wolfgang Rottbauer and Tillman Dahme
J. Cardiovasc. Dev. Dis. 2022, 9(9), 284; https://0-doi-org.brum.beds.ac.uk/10.3390/jcdd9090284 - 23 Aug 2022
Viewed by 1610
Abstract
Introduction: The optimal freeze duration in cryoballoon pulmonary vein isolation (PVI) is unknown. TTI-based titration of cryoenergy allows individualized freeze duration and has emerged as a favorable ablation strategy in PV cryoablation. In a recent study, we demonstrated that omission of a bonus [...] Read more.
Introduction: The optimal freeze duration in cryoballoon pulmonary vein isolation (PVI) is unknown. TTI-based titration of cryoenergy allows individualized freeze duration and has emerged as a favorable ablation strategy in PV cryoablation. In a recent study, we demonstrated that omission of a bonus freeze and reduction in freeze duration to a minimum of 2 min in the case of short TTI led to comparable arrhythmia recurrence rates. Whereas clinical outcome seems to be comparable to fixed freeze duration, evidence of long-term PV reconnection rates in patients undergoing TTI-based cryoballoon ablation is sparse. Aim of the study: To evaluate the procedural efficacy of a single 2-min freeze for PVI, we assessed PV conduction recovery after cryoballoon PVI with a TTI-guided titration of freeze duration compared to a fixed ablation protocol. Methods and Results: We included consecutive patients with atrial fibrillation (AF) recurrence undergoing a second ablation procedure after the initial cryoballoon procedure. The second AF ablation procedure was performed by the 3D-mapping system and radiofrequency ablation technique. A total of 219 patients (age: 66.2 ± 10.8 years, 53% female, paroxysmal AF: 53%) treated with the TTI-guided protocol (174 patients, 685 PV) or fixed protocol (45 patients, 179 PV) showed comparable total reconnection rates (TTI: 36.9% vs. fixed: 31.8%, p = 0.21). The PV reconnection rate was not statistically different for PVs treated with a 2-min freeze in case of short TTI, compared to longer freeze duration. Interestingly, the PV reconnection rate was lower in LIPVs treated with the fixed protocol (13% vs. 31%, p = 0.029). In the TTI group, 17 out of 127 patients (15%) had durable isolation of all PVs, whereas in 8 out of 40 patients (20%) in the fixed group, all PVs were still isolated (p = 0.31). Conclusions: overall reconnection rate was not different using a TTI-guided ablation protocol compared to a fixed ablation protocol, whereas the LIPV reconnection rate was significantly lower in patients treated with a fixed ablation protocol. Full article
(This article belongs to the Special Issue Catheter Ablation of Cardiac Arrhythmias: Practices and Outcomes)
Show Figures

Figure 1

9 pages, 1910 KiB  
Article
Very High-Power Short-Duration (HPSD) Ablation for Pulmonary Vein Isolation: Short and Long-Term Outcome Data
by Sebastian Seidl, Tanja Mülleder, Josef Kaiblinger, Stefan Sieghartsleitner, Jasmina Alibegovic-Zaborsky, Elisabeth Sigmund, Michael Derndorfer, Georg Kollias, Helmut Pürerfellner and Martin Martinek
J. Cardiovasc. Dev. Dis. 2022, 9(8), 278; https://0-doi-org.brum.beds.ac.uk/10.3390/jcdd9080278 - 18 Aug 2022
Cited by 5 | Viewed by 1676
Abstract
Background: Circumferential pulmonary vein isolation (PVI) using radiofrequency ablation (RFA) is a standard of care intervention for patients with symptomatic atrial fibrillation (AF). During follow-up, a substantial number of patients need a redo procedure due to reconnections on the basis of insufficient non-transmural [...] Read more.
Background: Circumferential pulmonary vein isolation (PVI) using radiofrequency ablation (RFA) is a standard of care intervention for patients with symptomatic atrial fibrillation (AF). During follow-up, a substantial number of patients need a redo procedure due to reconnections on the basis of insufficient non-transmural ablation lesions. High-power short-duration ablation (HPSD) is expected to create efficient lesions while causing fewer complications than in conventional RFA settings. The aim of this study was to compare one-year outcome data of very HPSD (90 Watt, 4 s) to a strategy using 50 Watt HPSD ablation guided by the CLOSE protocol using the Ablation Index (AI), an arbitrary unit composed of power, contact force and ablation time. Methods: We retrospectively analyzed short and long-term (median follow-up 23.2 ± 9.9 months) outcome data from 52 patients that were scheduled for first-do-symptomatic PVI. A very HPSD ablation protocol with 90 Watt and a 4 s duration cut-off was compared to an HPSD CLOSE approach (50 Watts; AI 550 at the anterior LA wall; AI 400 at the posterior LA wall, the roof and the floor) in terms of freedom from AF recurrence in a long-term electrocardiogram (ECG) over a five days surveillance period. To gain an impression of the subjective sense of wellbeing, the Atrial Fibrillation Effects on QualiTy-of-Life (AFEQT) score was recorded. Results: Overall freedom from AF was found in 81% (90 W 4 s) vs. 87.5% (50 W), (p = 0.52). There were 3 AF recurrences during the blanking period (90 W 4 s) vs. 1 (50 W). Within each population, one patient was scheduled for a redo-PVI-procedure. The AFEQT score was in favor of the 90 Watt 4 s approach (86.1 vs. 77.5; p = 0.37). Conclusion: Within our relatively small studied population, we found hints that in addition to shortening ablation times and radiation exposure without significantly increasing the rate of relevant intraprocedural complications, very high power short-duration ablation (90 W 4 s) provides comparable efficacy rates after one year. Full article
(This article belongs to the Special Issue Catheter Ablation of Cardiac Arrhythmias: Practices and Outcomes)
Show Figures

Figure 1

13 pages, 2179 KiB  
Article
Overcoming High Impedance in the Transitional Area of the Distal Great Cardiac Vein during Radiofrequency Catheter Ablation of Ventricular Arrhythmia
by Yan-Ru Chen, Yi-Fan Lin, Que Xu, Cheng Zheng, Rui-Lin He, Jin Li, Jia Li, Yue-Chun Li, Jia-Xuan Lin and Jia-Feng Lin
J. Cardiovasc. Dev. Dis. 2022, 9(8), 264; https://0-doi-org.brum.beds.ac.uk/10.3390/jcdd9080264 - 12 Aug 2022
Viewed by 1650
Abstract
(1) Background: Radiofrequency catheter ablation (RFCA) is an essential treatment for ventricular arrhythmia (VA). However, high impedance in the transitional area of the distal great cardiac vein (TAODGCV) often leads to ablation failure. This study aimed to explore the factors influencing impedance and [...] Read more.
(1) Background: Radiofrequency catheter ablation (RFCA) is an essential treatment for ventricular arrhythmia (VA). However, high impedance in the transitional area of the distal great cardiac vein (TAODGCV) often leads to ablation failure. This study aimed to explore the factors influencing impedance and identify effective ways to reduce impedance. (2) Methods: A total of 156 patients with VA arising from the TAODGCV received RFCA therapy at our center from October 2009 to August 2021 and were retrospectively analyzed. Local impedance variation during RFCA was monitored, recorded, and analyzed. (3) Results: The impedance increased from the proximal to distal portions of the TAODGCV and decreased by increasing the saline flow rate at the same site. To overcome high impedance, we implemented the following strategies: (1) Reset the upper limit impedance to 300 Ω and accelerate the saline flow rate to 60 mL/min (effective in 118 of 144 patients); (2) turn off the upper limit impedance (effective in eleven of 21 patients); (3) use high-flow-rate irrigation devices (effective in five of 15 patients); and (4) increase the upper limit temperature (effective in six of ten patients). (4) Conclusions: In the TAODGCV, local impedance is mainly influenced by the target site location and saline flow rate. We concluded several methods to overcome the high impedance and contribute to a successful ablation. Full article
(This article belongs to the Special Issue Catheter Ablation of Cardiac Arrhythmias: Practices and Outcomes)
Show Figures

Figure 1

16 pages, 7767 KiB  
Article
Left Atrial Anterior Wall Scar-Related Atrial Tachycardia in Patients after Catheter Ablation or Cardiac Surgery: Electrophysiological Characteristics and Ablation Strategy
by Hao Wang, Siqi Xi, Jindong Chen, Tian Gan, Weiye Huang, Ben He and Liang Zhao
J. Cardiovasc. Dev. Dis. 2022, 9(8), 249; https://0-doi-org.brum.beds.ac.uk/10.3390/jcdd9080249 - 05 Aug 2022
Cited by 5 | Viewed by 1784
Abstract
Background: The mechanisms of atrial tachycardia (AT) related to the left atrial anterior wall (LAAW) are complex and can be challenging to map in patients after catheter ablation for atrial fibrillation (AF) or cardiac surgery. We aimed to investigate the electrophysiological characteristics AT [...] Read more.
Background: The mechanisms of atrial tachycardia (AT) related to the left atrial anterior wall (LAAW) are complex and can be challenging to map in patients after catheter ablation for atrial fibrillation (AF) or cardiac surgery. We aimed to investigate the electrophysiological characteristics AT and to devise an ablation strategy. Methods and Results: We identified 31 scar-related LAAW reentrant ATs in 22 patients after catheter ablation for AF or cardiac surgery. Activation maps of the left atrium (LA) or both atria were obtained using a high-density mapping system, and the precise mechanism and critical area for each AT were analyzed. Patients were followed up regularly in a clinic. After analyzing the activation and propagation of each AT, the scar-related LAAW ATs were classified into three types, based on mechanisms related to: (1) LAAW conduction gap(s) in 19 LA macro-reentrant ATs; (2) LAAW epicardial connection(s) in 11 LA or bi-atrial ATs; and (3) LAAW local micro-reentry in 1 LAAW AT. Multiple ATs were identified in seven patients. Effective ablation (termination or circuit change of AT) was obtained in 30 ATs by targeting the critical area identified by the mapping system. During 16.0 ± 7.6 months follow-up, recurrent AT occurred in two patients. Conclusions: Three mechanisms of scar-related AT of LAAW were identified, most of which were related to LAAW conduction gaps. Notably, epicardial AT or bi-atrial AT comprised a nonnegligible proportion. A high-density mapping system could make it possible to determine the accurate mechanism of AT and serve as a guide following ablation. Full article
(This article belongs to the Special Issue Catheter Ablation of Cardiac Arrhythmias: Practices and Outcomes)
Show Figures

Figure 1

13 pages, 3337 KiB  
Article
Characteristics and Prognostic Relevance of Ventricular Arrhythmia in Patients with Myocarditis
by Ann-Kathrin Kahle, Rebekka Güde, Jana M. Schwarzl, Paula Münkler, Ruken Ö. Akbulak, Charlotte Jahnke, Sebastian Bohnen, Tilman Würger, Michael Schwarzl, Stephan Willems, Ulf K. Radunski and Christian Meyer
J. Cardiovasc. Dev. Dis. 2022, 9(8), 243; https://0-doi-org.brum.beds.ac.uk/10.3390/jcdd9080243 - 29 Jul 2022
Viewed by 2791
Abstract
Myocarditis is characterized by various clinical manifestations, with ventricular arrhythmia (VA) as a frequent symptom at initial presentation. Here, we investigated characteristics and prognostic relevance of VA in patients with myocarditis. The study population consisted of 76 patients with myocarditis, verified by biopsy [...] Read more.
Myocarditis is characterized by various clinical manifestations, with ventricular arrhythmia (VA) as a frequent symptom at initial presentation. Here, we investigated characteristics and prognostic relevance of VA in patients with myocarditis. The study population consisted of 76 patients with myocarditis, verified by biopsy and/or cardiac magnetic resonance (CMR) imaging, including 38 consecutive patients with VA (45 ± 3 years, 68% male) vs. 38 patients without VA (NVA) (38 ± 2 years, 84% male) serving as a control group. VA was monomorphic ventricular tachycardia in 55% of patients, premature ventricular complexes in 50% and ventricular fibrillation in 29%. The left ventricular ejection fraction at baseline was 47 ± 2% vs. 40 ± 3% in VA vs. NVA patients (p = 0.069). CMR showed late gadolinium enhancement more often in VA patients (94% vs. 69%; p = 0.016), incorporating 17.6 ± 1.8% vs. 8.2 ± 1.3% of myocardial mass (p < 0.001). Radiofrequency catheter ablation for VA was initially performed in nine (24%) patients, of whom five remained free from any recurrence over 24 ± 3 months. Taken together, in patients with myocarditis, reduced left ventricular ejection fraction does not predict VA occurrence but CMR shows late gadolinium enhancement more frequently and to a larger extent in VA than in NVA patients, potentially guiding catheter ablation as a reasonable treatment of VA in this population. Full article
(This article belongs to the Special Issue Catheter Ablation of Cardiac Arrhythmias: Practices and Outcomes)
Show Figures

Figure 1

12 pages, 5052 KiB  
Article
Electroporation Parameters for Human Cardiomyocyte Ablation In Vitro
by Jara M. Baena-Montes, Tony O’Halloran, Cormac Clarke, Kevin Donaghey, Eoghan Dunne, Martin O’Halloran and Leo R. Quinlan
J. Cardiovasc. Dev. Dis. 2022, 9(8), 240; https://0-doi-org.brum.beds.ac.uk/10.3390/jcdd9080240 - 28 Jul 2022
Cited by 12 | Viewed by 2702
Abstract
Cardiac ablation with irreversible electroporation (IRE) is quickly being established as a modality of choice for atrial fibrillation treatment. While it has not yet been optimised, IRE has the potential to significantly limit collateral damage and improve cell-specific targeting associated with other energy [...] Read more.
Cardiac ablation with irreversible electroporation (IRE) is quickly being established as a modality of choice for atrial fibrillation treatment. While it has not yet been optimised, IRE has the potential to significantly limit collateral damage and improve cell-specific targeting associated with other energy sources. However, more tissue and cell-specific evidence is required to demonstrate the selective threshold parameters for human cells. The aim here is to determine the optimal ablation threshold parameters related to lesion size for human cardiomyocytes in 2D culture. Conventional biphasic pulses of different field strengths and on-times were delivered in a monolayer culture system of human AC16 cardiomyocytes. The dynamics of cell death and lesion dimensions were examined at different time points. Human cardiomyocytes are susceptible to significant electroporation and cell death at a field strength of 750 V/cm or higher with 100 μs pulses. Increasing the IRE on-time from 3 ms to 60 ms reduces the effective field threshold to 250 V/cm. Using very short pulses of 2 μs and 5 μs also causes significant cell death, but only at fields higher than 1000 V/cm. A longer on-time results in more cell death and induced greater lesion area in 2D models. In addition, different forms of cell death are predicted based on the evolution of cell death over time. This study presents important findings on the ability of different IRE parameters to induce human cardiomyocyte cell death. Lesion size can be tuned by appropriate choice of IRE parameters and cardiomyocytes display an upregulation of delayed cell death 24 h after electroporation, which is an important consideration for clinical practice. Full article
(This article belongs to the Special Issue Catheter Ablation of Cardiac Arrhythmias: Practices and Outcomes)
Show Figures

Figure 1

10 pages, 1753 KiB  
Article
Comparison between Standard and High-Definition Multi-Electrode Mapping Catheter in Ventricular Tachycardia Ablation
by Sergio Conti, Francesco Sabatino, Gabriele De Blasi, Giuseppe Di Stabile and Giuseppe Sgarito
J. Cardiovasc. Dev. Dis. 2022, 9(8), 232; https://0-doi-org.brum.beds.ac.uk/10.3390/jcdd9080232 - 22 Jul 2022
Cited by 2 | Viewed by 1818
Abstract
A high-definition mapping catheter has been introduced, allowing for bipolar recording along and across the spline with a rapid assessment of voltage, activation, and directionality of conduction. We aimed to evaluate differences in mapping density, accuracy, time, and consequently RF time between different [...] Read more.
A high-definition mapping catheter has been introduced, allowing for bipolar recording along and across the spline with a rapid assessment of voltage, activation, and directionality of conduction. We aimed to evaluate differences in mapping density, accuracy, time, and consequently RF time between different mapping catheters used for ventricular tachycardia (VT) ablation. We enrolled consecutive patients undergoing VT ablation at our center. Patients were divided into the LiveWire 2-2-2 mm catheter (group A) and the HD Grid SE (group B). Primary endpoints were total RF delivery time, the number of points acquired in sinus rhythm and VT, and the scar area. Fifty-one patients were enrolled, 22 in group A and 29 in group B. More points were acquired in the Grid group in sinus rhythm (SR) and during VT (2060.78 ± 1600.38 vs. 3278.63 ± 3214.45, p = 0.05; 4201.13 ± 5141.61 vs. 10,569.43 ± 13,644.94, p = 0.02, respectively). The scar area was smaller in group B (Bipolar area, cm2 4.52 ± 2.72 vs. 2.89 ± 2.81, p = 0.05. Unipolar area, cm2 7.47 ± 4.55 vs. 5.56 ± 2.79, p = 0.03). Radiofrequency (RF) time was shorter in the Grid group (30.52 ± 13.94 vs. 22.16 ± 11.03, p = 0.014). LPs and LAVAs were eliminated in overall >93% of patients. No differences were found in terms of arrhythmia-free survival at follow-up. In conclusion, the use of a high-definition mapping catheter was associated with significantly shorter mapping time during VT and RF time. Significantly more points were acquired in SR and during VT. During remap, we also observed more LAVAs and LPs requiring further ablation. Full article
(This article belongs to the Special Issue Catheter Ablation of Cardiac Arrhythmias: Practices and Outcomes)
Show Figures

Figure 1

11 pages, 1355 KiB  
Article
Unipolar Electrogram-Guided versus Lesion Size Index-Guided Catheter Ablation in Patients with Paroxysmal Atrial Fibrillation
by Guohua Fu, Bin He, Binhao Wang, Mingjun Feng, Xianfeng Du, Jing Liu, Yibo Yu, Fang Gao, Weidong Zhuo, Yi Xu, Yingbo Qi and Huimin Chu
J. Cardiovasc. Dev. Dis. 2022, 9(7), 229; https://0-doi-org.brum.beds.ac.uk/10.3390/jcdd9070229 - 18 Jul 2022
Cited by 4 | Viewed by 1580
Abstract
Background: This research explores the relationship between the unipolar electrogram (UP-EGM) and lesion size index (LSI) in different regions of continuous circular lesions (CCLs) and to assess the safety and efficacy of UP-EGM-guided versus LSI-guided radiofrequency catheter ablation (RFCA) in patients with paroxysmal [...] Read more.
Background: This research explores the relationship between the unipolar electrogram (UP-EGM) and lesion size index (LSI) in different regions of continuous circular lesions (CCLs) and to assess the safety and efficacy of UP-EGM-guided versus LSI-guided radiofrequency catheter ablation (RFCA) in patients with paroxysmal atrial fibrillation (PAF). Methods: A total of 120 patients with drug-refractory PAF who underwent index RFCA were scheduled to be consecutively included from March 2020 to April 2021. All the patients were randomly divided 1:1 into two groups: the UP-EGM group and the LSI group. The first-pass PVI rate, acute PVI rate, and the sinus rhythm maintenance rate were compared. Results: A total of 120 patients with PAF were included in the study: the UP-EGM group (n = 60) and the LSI group (n = 60). All the LSI values in the UP-EGM group were less than those in the corresponding regions in the LSI group (all p < 0.001). There were no significant differences in the first-pass PVI rate and acute PVI rate between the two groups. After a mean follow-up period of 11.31 ± 1.70 months, the sinus rhythm maintenance rate in the UP-EGM group was comparable to that in the LSI group (90% vs. 91.7%, p = 0.752). Conclusion: UP-EGM-guided and LSI-guided RFCA are both effective and safe in patients with PAF. However, UP-EGM may be more suitable than LSI for guiding individual RFCA. Full article
(This article belongs to the Special Issue Catheter Ablation of Cardiac Arrhythmias: Practices and Outcomes)
Show Figures

Figure 1

17 pages, 1806 KiB  
Article
Extracardiac Vagal Stimulation-Assisted Cardioneuroablation: Dynamically Evaluating the Impact of Sequential Ganglionated Plexus Ablation on Vagal Control of SAN and AVN in Patients with Sinoatrial Node Dysfunction
by Weijie Chen, Zengzhang Liu, Peilin Xiao, Yanping Xu, Dan Li, Qingsong Xiong, Lili Zou, Fang Qin, Xiexin Tao, Junan Chen, Xianbin Lan, Huaan Du, Yuehui Yin and Zhiyu Ling
J. Cardiovasc. Dev. Dis. 2022, 9(6), 188; https://0-doi-org.brum.beds.ac.uk/10.3390/jcdd9060188 - 10 Jun 2022
Cited by 5 | Viewed by 2455
Abstract
Cardioneuroablation (CNA) is proposed as a promising therapy for patients with sinoatrial node dysfunction (SND) that is mediated by excessive vagal tone. However, a series of urgent questions about CNA remain unanswered. From December 2020 to March 2022, six patients with symptomatic SND [...] Read more.
Cardioneuroablation (CNA) is proposed as a promising therapy for patients with sinoatrial node dysfunction (SND) that is mediated by excessive vagal tone. However, a series of urgent questions about CNA remain unanswered. From December 2020 to March 2022, six patients with symptomatic SND who underwent CNA were summarized in this report. Sequential CNA targeting Ao-SVC GP, PMLGP, RAGP, and LSGP was performed in patients, guided by fractionated intracardiac electrograms and dynamically evaluated by extracardiac vagal stimulation (ECVS). The results showed that Ao-SVC GP ablation led to a significant increase in heart rate (HR) and the elimination of sinus arrest evoked by ECVS, while the vagal responses of atrial ventricular block were eliminated by the ablation of PMLGP and LSGP. Post-procedure HR increased up to 64–86% of the maximum HR of an atropine test at baseline. The median HR from Holter monitoring increased from 52.8 ± 2.1 bpm at baseline to 73.0 ± 10.4 bpm after the procedure (p = 0.012) and to 71.3 ± 10.1 bpm at the six-month follow-up (p = 0.011). Bradycardia-related symptoms disappeared in all patients at the six-month follow-up. This case series reveals the feasibility of using the ECVS-assisted sequential CNA technique and indicates the critical role of ECVS in dynamically evaluating the impact of sequential CNA on the vagal control of SAN and AVN. Full article
(This article belongs to the Special Issue Catheter Ablation of Cardiac Arrhythmias: Practices and Outcomes)
Show Figures

Figure 1

16 pages, 1229 KiB  
Article
The Relevance of Heart Rate Fluctuation When Evaluating Atrial Substrate Electrical Features in Catheter Ablation of Paroxysmal Atrial Fibrillation
by Aikaterini Vraka, José Moreno-Arribas, Juan M. Gracia-Baena, Fernando Hornero, Raúl Alcaraz and José J. Rieta
J. Cardiovasc. Dev. Dis. 2022, 9(6), 176; https://0-doi-org.brum.beds.ac.uk/10.3390/jcdd9060176 - 01 Jun 2022
Cited by 1 | Viewed by 1672
Abstract
Coronary sinus (CS) catheterization is critical during catheter ablation (CA) of atrial fibrillation (AF). However, the association of CS electrical activity with atrial substrate modification has been barely investigated and mostly limited to analyses during AF. In sinus rhythm (SR), atrial substrate modification [...] Read more.
Coronary sinus (CS) catheterization is critical during catheter ablation (CA) of atrial fibrillation (AF). However, the association of CS electrical activity with atrial substrate modification has been barely investigated and mostly limited to analyses during AF. In sinus rhythm (SR), atrial substrate modification is principally assessed at a global level through P-wave analysis. Cross-correlating CS electrograms (EGMs) and P-waves’ features could potentiate the understanding of AF mechanisms. Five-minute surface lead II and bipolar CS recordings before, during, and after CA were acquired from 40 paroxysmal AF patients. Features related to duration, amplitude, and heart-rate variability of atrial activations were evaluated. Heart-rate adjustment (HRA) was applied. Correlations between each P-wave and CS local activation wave (LAW) feature were computed with cross-quadratic sample entropy (CQSE), Pearson correlation (PC), and linear regression (LR) with 10-fold cross-validation. The effect of CA between different ablation steps was compared with PC. Linear correlations: poor to mediocre before HRA for analysis at each P-wave/LAW (PC: max. +18.36%, p = 0.0017, LR: max. +5.33%, p = 0.0002) and comparison between two ablation steps (max. +54.07%, p = 0.0205). HRA significantly enhanced these relationships, especially in duration (P-wave/LAW: +43.82% to +69.91%, p < 0.0001 for PC and +18.97% to +47.25%, p < 0.0001 for LR, CA effect: +53.90% to +85.72%, p < 0.0210). CQSE reported negligent correlations (0.6–1.2). Direct analysis of CS features is unreliable to evaluate atrial substrate modification due to CA. HRA substantially solves this problem, potentiating correlation with P-wave features. Hence, its application is highly recommended. Full article
(This article belongs to the Special Issue Catheter Ablation of Cardiac Arrhythmias: Practices and Outcomes)
Show Figures

Figure 1

10 pages, 994 KiB  
Article
Does a Vagal Response Indicate Cardiac Autonomic Modulation and Improve the Therapeutic Effect of Pulmonary Vein Isolation in Patients with Paroxysmal Atrial Fibrillation? Insights from Cryoballoon Ablation
by Radoslaw M. Kiedrowicz, Maciej Wielusinski, Marcin Zakrzewski and Jaroslaw Kazmierczak
J. Cardiovasc. Dev. Dis. 2022, 9(5), 142; https://0-doi-org.brum.beds.ac.uk/10.3390/jcdd9050142 - 02 May 2022
Viewed by 2050
Abstract
Background: The incidence and influence of vagal response (VR) observed during cryoballoon-based pulmonary vein isolation (CBA-based PVI) on the cardiac autonomic nervous system (CANS) and ablation outcomes in paroxysmal atrial fibrillation (PAF) remain unknown. Methods: 296 patients were treated with a 28 mm [...] Read more.
Background: The incidence and influence of vagal response (VR) observed during cryoballoon-based pulmonary vein isolation (CBA-based PVI) on the cardiac autonomic nervous system (CANS) and ablation outcomes in paroxysmal atrial fibrillation (PAF) remain unknown. Methods: 296 patients were treated with a 28 mm second-generation cryoballoon (Medtronic). A total of 74 patients without structural heart disease and concomitant diseases were chosen for a detailed CANS assessment with a heart rate variability (HRV) analysis. All patients were screened over a 2-year post-ablation period. Results: VR was detected in 30% of patients and included sinus arrest (64%) or severe sinus bradycardia (46%). The presence of VR was not related to PV ostial dimension, patient clinical characteristics or intraprocedural ablation details. CANS modulation, manifesting as increased median HR and decreased HRV parameters with intact sympatho-vagal balance occurred independently of VR presence or absence and sustained for at least 12 months following ablation. VR was not related with more intensive CANS modulation and did not translate into better ablation outcomes when compared to the non-VR group (74% vs. 71% at 12 months and 69% vs. 65% at 24 months respectively). Conclusions: VR is frequent during CBA-based PVI for PAF and unrelated to any additional clinical benefit. Full article
(This article belongs to the Special Issue Catheter Ablation of Cardiac Arrhythmias: Practices and Outcomes)
Show Figures

Figure 1

12 pages, 571 KiB  
Article
Chronic Kidney Disease with Mild and Mild to Moderate Reduction in Renal Function and Long-Term Recurrences of Atrial Fibrillation after Pulmonary Vein Cryoballoon Ablation
by Giuseppe Boriani, Saverio Iacopino, Giuseppe Arena, Paolo Pieragnoli, Roberto Verlato, Massimiliano Manfrin, Giulio Molon, Giovanni Rovaris, Antonio Curnis, Giovanni Battista Perego, Antonio Dello Russo, Maurizio Landolina, Marco Vitolo, Claudio Tondo and on behalf of the 1STOP ClinicalService Investigators
J. Cardiovasc. Dev. Dis. 2022, 9(5), 126; https://0-doi-org.brum.beds.ac.uk/10.3390/jcdd9050126 - 21 Apr 2022
Cited by 4 | Viewed by 2564
Abstract
The aim of this research was to evaluate if patients with chronic kidney disease (CKD) and mild or mild to moderate depression of renal function have an increased risk of atrial fibrillation (AF) recurrences after cryoballoon (CB) ablation. We performed a retrospective analysis [...] Read more.
The aim of this research was to evaluate if patients with chronic kidney disease (CKD) and mild or mild to moderate depression of renal function have an increased risk of atrial fibrillation (AF) recurrences after cryoballoon (CB) ablation. We performed a retrospective analysis of AF patients undergoing pulmonary vein isolation (PVI) by CB. The cohort was divided according to the KDIGO CKD-EPI classification into a (1) normal, (2) mildly decreased, or (3) mild to moderate reduction in estimated glomerular filtration rate (eGFR). Freedom from AF recurrences was the primary endpoint. A total of 1971 patients were included (60 ± 10 years, 29.0% females, 73.6% paroxysmal AF) in the study. Acute success and complication rates were 99.2% and 3.7%, respectively, with no significant differences among the three groups. After a follow-up of 24 months, AF recurrences were higher in the mildly and mild to moderate CKD groups compared to the normal kidney function group (23.4% vs. 28.3% vs. 33.5%, p < 0.05). Mild to moderate CKD was an independent predictor of AF recurrences after the blanking period (hazard ratio:1.38, 95% CI 1.02–1.86, p = 0.037). In conclusion, a multicenter analysis of AF patients treated with cryoablation revealed mild to moderate reductions in renal functions were associated with a higher risk of AF recurrences. Conversely, the procedural success and complication rates were similar in patients with normal, mildly reduced, or mild to moderate reduction in eGFR. Full article
(This article belongs to the Special Issue Catheter Ablation of Cardiac Arrhythmias: Practices and Outcomes)
Show Figures

Figure 1

13 pages, 3148 KiB  
Article
The Effect of Discharge Mode on the Distribution of Myocardial Pulsed Electric Field—A Simulation Study for Pulsed Field Ablation of Atrial Fibrillation
by Xingkai Ji, Hao Zhang, Lianru Zang, Shengjie Yan and Xiaomei Wu
J. Cardiovasc. Dev. Dis. 2022, 9(4), 95; https://0-doi-org.brum.beds.ac.uk/10.3390/jcdd9040095 - 24 Mar 2022
Cited by 6 | Viewed by 2850
Abstract
Background: At present, the effects of discharge modes of multielectrode catheters on the distribution of pulsed electric fields have not been completely clarified. Therefore, the control of the distribution of the pulsed electric field by selecting the discharge mode remains one of the [...] Read more.
Background: At present, the effects of discharge modes of multielectrode catheters on the distribution of pulsed electric fields have not been completely clarified. Therefore, the control of the distribution of the pulsed electric field by selecting the discharge mode remains one of the key technical problems to be solved. Methods: We constructed a model including myocardium, blood, and a flower catheter. Subsequently, by setting different positive and ground electrodes, we simulated the electric field distribution in the myocardium of four discharge modes (A, B, C, and D) before and after the catheter rotation and analyzed their mechanisms. Results: Modes B, C, and D formed a continuous circumferential ablation lesion without the rotation of the catheter, with depths of 1.6 mm, 2.7 mm, and 0.7 mm, respectively. After the catheter rotation, the four modes could form a continuous circumferential ablation lesion with widths of 10.8 mm, 10.6 mm, 11.8 mm, and 11.5 mm, respectively, and depths of 5.2 mm, 2.7 mm, 4.7 mm, and 4.0 mm, respectively. Conclusions: The discharge mode directly affects the electric field distribution in the myocardium. Our results can help improve PFA procedures and provide enlightenment for the design of the discharge mode with multielectrode catheters. Full article
(This article belongs to the Special Issue Catheter Ablation of Cardiac Arrhythmias: Practices and Outcomes)
Show Figures

Figure 1

12 pages, 1764 KiB  
Article
Comparison of the Mid-Term Outcomes of Robotic Magnetic Navigation-Guided Radiofrequency Ablation versus Cryoballoon Ablation for Persistent Atrial Fibrillation
by Xiang Li, Yangyang Bao, Kangni Jia, Ning Zhang, Changjian Lin, Yue Wei, Yun Xie, Qingzhi Luo, Tianyou Ling, Kang Chen, Wenqi Pan, Liqun Wu and Qi Jin
J. Cardiovasc. Dev. Dis. 2022, 9(3), 88; https://0-doi-org.brum.beds.ac.uk/10.3390/jcdd9030088 - 17 Mar 2022
Cited by 5 | Viewed by 2251
Abstract
Introduction: Currently, numerous ablation techniques are available for atrial fibrillation (AF), in addition to manual radio frequency ablation. The aim of this prospective, non-randomized concurrent controlled trial was to compare the mid-term efficacy and procedural outcomes of persistent AF (PerAF) using cryoballoon (CB) [...] Read more.
Introduction: Currently, numerous ablation techniques are available for atrial fibrillation (AF), in addition to manual radio frequency ablation. The aim of this prospective, non-randomized concurrent controlled trial was to compare the mid-term efficacy and procedural outcomes of persistent AF (PerAF) using cryoballoon (CB) and robotic magnetic navigation (RMN). Methods: Two hundred PerAF patients were assigned, in a 1:1 ratio, to undergo catheter ablation using RMN (RMN group) or CB (CB group). The primary endpoint was freedom from AF recurrence following a 3-month period after the index ablation. The secondary endpoint was peri-procedural outcomes, including the total procedure time, left atrial procedure time, fluoroscopy time, and fluoroscopy dose. The Two-step cluster analysis was used to determine the efficacy of RMN and CB between the different groups. The Cox proportional hazard model and restricted cubic spline were used to determine predictors for AF recurrence. Results: At the mean follow-up of 28.1 ± 9.7 months, the primary endpoint was achieved in 71 PerAF patients in the RMN group and in 62 PerAF patients in the CB group (71% vs. 62%, p = 0.158). Compared with CB, RMN-guided ablation led to a longer procedure time (p < 0.001), but with less radiation (p < 0.001). Cluster analysis returned two clusters of patients and RMN was favorable for one cluster (p = 0.037), in which more patients presented with diabetes mellitus and smaller left atria. Conclusions: For patients with PerAF, CB is generally equivalent to RMN-guided ablation with regard to overall efficacy. RMN-guided ablation could be favorable in specific patient populations presenting with diabetes mellitus and smaller left atria. Full article
(This article belongs to the Special Issue Catheter Ablation of Cardiac Arrhythmias: Practices and Outcomes)
Show Figures

Figure 1

19 pages, 5818 KiB  
Article
Idiopathic Ventricular Arrhythmias Originating from Different Portions of the Coronary Venous System: Prevalence, Electrocardiographic Characteristics, Catheter Ablation, and Complications
by Yaoji Wang, Jiameng Shao, Bing Shen, Cheng Zheng, Jin Li, Que Xu, Yifan Lin and Jiafeng Lin
J. Cardiovasc. Dev. Dis. 2022, 9(3), 78; https://0-doi-org.brum.beds.ac.uk/10.3390/jcdd9030078 - 07 Mar 2022
Cited by 1 | Viewed by 2391
Abstract
(1) Background: To determine the prevalence, electrocardiographic characteristics, mapping, and ablation of IVAs arising from the CVS. (2) Methods: Detailed activation and pace mapping of the CVS IVAs was performed before attempted radiofrequency ablation (RFCA). (3) Results: The IVAs originating from the vicinity [...] Read more.
(1) Background: To determine the prevalence, electrocardiographic characteristics, mapping, and ablation of IVAs arising from the CVS. (2) Methods: Detailed activation and pace mapping of the CVS IVAs was performed before attempted radiofrequency ablation (RFCA). (3) Results: The IVAs originating from the vicinity of the CVS represented approximately 5.27% (164/3113) of all IVAs; 94.51% (155/164) cases were accessed at the earliest identified site and 83.54% (137/164) IVAs were successfully ablated. The main coronary vein group had a relatively short procedure time, short fluoroscopy time, fewer radiofrequency lesions prior to success, and less Swartz sheath support. IVAs originating from the CVS had distinct ECG characteristics: Rs, RS or rS (with s or S) wave in lead V1 indicate the Vas arising from the proximal portion of the anterior interventricular vein (AIV) and summit-CV; Rs (with s or S) wave in leads V5–V6 indicate the Vas arising from the adjacent regions of the distal great cardiac vein 1 (DGCV1); positive wave (R, Rs or r) In lead I indicate the VAs ori”inat’ng from Summit-CV and posterior wall subgroup (including middle cardiac vein [MCV], posterior lateral vein [PLV], coronary sinus [CS]). Compared with the IVAs originating from the endocardial mitral annulus, a PdW > 45 ms, an IDT > 74 ms, and an MDI > 0.50 indicate a CVS origin of the IVAs. The common peri-procedure complications were CV dissection (6.45%, 10/155), CV rupture (1.29%, 2/155), coronary artery spasm (1.29%, 2/155), coronary artery stenosis (0.65%, 1/155), pericardial effusion (0.65%, 1/155) and tamponade (1.29%, 2/155). Stenosis of coronary arteries was not observed at the adjacent ablation site in the CVS during follow-up. (4) Conclusions: vAs arising from the CVS are not a rare phenomenon. Several ECG and procedure characteristics could help regionalize, map, and ablate the origin of IVAs from different portions of the CVS. RFCA within the CVS was relatively effective and safe. Full article
(This article belongs to the Special Issue Catheter Ablation of Cardiac Arrhythmias: Practices and Outcomes)
Show Figures

Figure 1

11 pages, 1242 KiB  
Article
The Incidence, Electrophysiological Characteristics and Ablation Outcome of Left Atrial Tachycardias after Pulmonary Vein Isolation Using Three Different Ablation Technologies
by Patrick Leitz, Kristina Wasmer, Christian Andresen, Fatih Güner, Julia Köbe, Benjamin Rath, Florian Reinke, Julian Wolfes, Philipp S. Lange, Christian Ellermann, Gerrit Frommeyer and Lars Eckardt
J. Cardiovasc. Dev. Dis. 2022, 9(2), 50; https://0-doi-org.brum.beds.ac.uk/10.3390/jcdd9020050 - 03 Feb 2022
Cited by 2 | Viewed by 1725
Abstract
Background: Left atrial tachycardias (LAT) are a well-known outcome of pulmonary vein isolation (PVI). Few data are available on whether the catheter used to perform PVI influences the incidence, as well as the characteristics of post PVI LAT. We present data on LAT [...] Read more.
Background: Left atrial tachycardias (LAT) are a well-known outcome of pulmonary vein isolation (PVI). Few data are available on whether the catheter used to perform PVI influences the incidence, as well as the characteristics of post PVI LAT. We present data on LAT following PVI by the following three ablation technologies: (1) phased multi-electrode radiofrequency catheter (PVAC), (2) irrigated single-tip catheter (iRF), and (3) cryoballoon ablation. Methods: Using a prospectively designed single-center database, we analyzed 650 patients (300 iRF, 150 PVAC, and 200 cryoballoon) with paroxysmal (n = 401) and persistent atrial fibrillation (AF), who underwent their first PVI at our center. Results: The three populations were comparable in their baseline characteristics; however, the cryoballoon group comprised a higher percentage of patients with persistent AF (p = 0.05). The LAT rates were 3.7% in the iRF group (mean follow-up 22 ± 14 months), 0.7% in the PVAC group (mean follow-up 21 ± 14 months), and 4% in the cryoballoon group (mean follow-up 15 ± 8 months). The predominant mechanism of LAT was macro-reentrant tachycardia. Reconnection of at least one pulmonary vein was observed in 87% of the patients who underwent 3D mapping. No predictors for LAT occurrence were identified. Conclusion: The occurrence of LAT post PVI is rare; the predominant mechanism was macro-reentrant tachycardia. Reconnection of at least one pulmonary vein was observed in nearly all the LAT patients. In our retrospective analysis, the lowest rate of LAT was observed with the PVAC. No predictors for LAT occurrence were identified. Full article
(This article belongs to the Special Issue Catheter Ablation of Cardiac Arrhythmias: Practices and Outcomes)
Show Figures

Figure 1

12 pages, 811 KiB  
Article
Left Atrial Appendage Thrombus in Patients with Nonvalvular Atrial Fibrillation before Catheter Ablation and Cardioversion: Risk Factors beyond the CHA2DS2-VASc Score
by Yangwei Cai, Qingsong Xiong, Shaojie Chen, Xi Jiang, Jia Liao, Weijie Chen, Lili Zou, Lei Su, Yefeng Zhu, Yuehui Yin and Zhiyu Ling
J. Cardiovasc. Dev. Dis. 2022, 9(2), 46; https://0-doi-org.brum.beds.ac.uk/10.3390/jcdd9020046 - 30 Jan 2022
Cited by 5 | Viewed by 2987
Abstract
Left atrial appendage thrombus (LAAT) is a surrogate of thromboembolic events in patients with nonvalvular atrial fibrillation (NVAF). We aimed to investigate the risk factors for LAAT formation before catheter ablation and cardioversion beside the CHA2DS2-VASc score. In this case-control study, patients with [...] Read more.
Left atrial appendage thrombus (LAAT) is a surrogate of thromboembolic events in patients with nonvalvular atrial fibrillation (NVAF). We aimed to investigate the risk factors for LAAT formation before catheter ablation and cardioversion beside the CHA2DS2-VASc score. In this case-control study, patients with NVAF who underwent transesophageal echocardiography (TEE) were included. Demographic data, laboratory results, and echocardiographic measurements were retrospectively collected. Logistic regression analysis was performed to determine risk factors predicting LAAT. Of the 543 included patients, LAAT was identified in 50 patients (9.2%). Multivariable logistic regression analysis for the entire cohort showed that NT-proBNP (per 500 ng/L increase, OR (95% CI): 1.09 (1.00–1.19), p = 0.038) and LDL-C (per 1 mmol/L increase, OR (95% CI): 1.70 (1.05–2.77), p = 0.032) were independently correlated with the presence of LAAT after the adjustment for CHA2DS2-VASc score and anticoagulant therapy. The subgroup analysis of patients without anticoagulant therapy also yielded similar results. Regarding patients with CHA2DS2-VASc scores ≤ 1, a higher level of LDL-C (per 1 mmol/L increase, OR (95% CI): 6.31 (2.38–16.74), p < 0.001) independently correlated with the presence of LAAT. The present study suggests that beyond CHA2DS2-VASc score, raised NT-proBNP and LDL-C are additional predictors for LAAT in NVAF patients. Full article
(This article belongs to the Special Issue Catheter Ablation of Cardiac Arrhythmias: Practices and Outcomes)
Show Figures

Figure 1

9 pages, 971 KiB  
Article
News from the Cold Chamber: Clinical Experiences of POLARx versus Arctic Front Advance for Single-Shot Pulmonary Vein Isolation
by Denise Guckel, Philipp Lucas, Khuraman Isgandarova, Mustapha El Hamriti, Leonard Bergau, Thomas Fink, Vanessa Sciacca, Guram Imnadze, Martin Braun, Moneeb Khalaph, Georg Nölker, Philipp Sommer and Christian Sohns
J. Cardiovasc. Dev. Dis. 2022, 9(1), 16; https://0-doi-org.brum.beds.ac.uk/10.3390/jcdd9010016 - 08 Jan 2022
Cited by 15 | Viewed by 2723
Abstract
Cryoballoon (CB)-guided pulmonary vein isolation (PVI) represents a cornerstone in the treatment of atrial fibrillation (AF). Recently, a novel balloon-guided single shot device (POLARx, Boston Scientific) was designed. Our study aimed to compare the efficacy, safety and characteristics of the novel CB system [...] Read more.
Cryoballoon (CB)-guided pulmonary vein isolation (PVI) represents a cornerstone in the treatment of atrial fibrillation (AF). Recently, a novel balloon-guided single shot device (POLARx, Boston Scientific) was designed. Our study aimed to compare the efficacy, safety and characteristics of the novel CB system with the established one (Arctic Front Advance (Pro), AFA, Medtronic). A total number of 596 patients undergoing CB-guided ablation for AF were included. 65 patients (65.0 ± 11.6, 31% female) undergoing PVI with the POLARx were compared to a cohort of 531 consecutive patients (63.0 ± 27.9, 25% female) treated with AFA. Acute PVI was achieved in all patients (n = 596, 100%). Total procedure duration (POLARx 113.3 ± 23.2 min, AFA 100.9 ± 21.3 min; p < 0.001) and fluoroscopy time (POLARx 10.5 ± 5.9 min, AFA 4.8 ± 3.6 min; p < 0.001) were significantly longer in the POLARx group. The POLARx balloon achieved significantly lower nadir temperatures (POLARx −57.7 ± 0.9 °C, AFA −45.1 ± 2.6 °C; p < 0.001) and a significantly higher percentage of pulmonary veins successfully isolated with the first freeze (p = 0.027 *). One major complication occurred in the POLARx (2%) and three (1%) in the AFA group. Both ablation systems are comparably safe and effective. AF ablation utilizing the POLARx system is associated with longer procedure and fluoroscopy times as well as lower nadir temperatures. Full article
(This article belongs to the Special Issue Catheter Ablation of Cardiac Arrhythmias: Practices and Outcomes)
Show Figures

Graphical abstract

Review

Jump to: Research, Other

12 pages, 1430 KiB  
Review
Hybrid Ablation of Atrial Fibrillation: A Contemporary Overview
by Massimiliano Marini, Luigi Pannone, Domenico G. Della Rocca, Stefano Branzoli, Antonio Bisignani, Sahar Mouram, Alvise Del Monte, Cinzia Monaco, Anaïs Gauthey, Ivan Eltsov, Ingrid Overeinder, Gezim Bala, Alexandre Almorad, Erwin Ströker, Juan Sieira, Pedro Brugada, Mark La Meir, Gian-Battista Chierchia, Carlo De Asmundis and Fabrizio Guarracini
J. Cardiovasc. Dev. Dis. 2022, 9(9), 302; https://0-doi-org.brum.beds.ac.uk/10.3390/jcdd9090302 - 08 Sep 2022
Cited by 6 | Viewed by 2258
Abstract
Electrical isolation of pulmonary veins (PVI) is the cornerstone of invasive treatment of atrial fibrillation (AF). However, arrhythmia-free survival of a PVI only approach is suboptimal in patients with persistent and long-term persistent AF. Hybrid AF ablation has been developed with the aim [...] Read more.
Electrical isolation of pulmonary veins (PVI) is the cornerstone of invasive treatment of atrial fibrillation (AF). However, arrhythmia-free survival of a PVI only approach is suboptimal in patients with persistent and long-term persistent AF. Hybrid AF ablation has been developed with the aim of combining the advantages of a thoracoscopic surgical ablation (direct visualization of anatomical structures to be spared and the possibility to perform epicardial lesions) and endocardial ablation (possibility to check line block, confirm PVI, and possibility to perform cavotricuspid isthmus ablation). Patient selection is of utmost importance. In persistent and long-term persistent AF, hybrid AF ablation demonstrated promising results in terms of AF free survival. It has been associated with a relatively low complication rate if performed in centers with expertise in hybrid procedures and experience with both surgical and endocardial ablation. Different techniques have been described, with different approaches and lesion sets. The aim of this review is to provide a state-of-the-art overview of hybrid AF ablation. Full article
(This article belongs to the Special Issue Catheter Ablation of Cardiac Arrhythmias: Practices and Outcomes)
Show Figures

Figure 1

15 pages, 3062 KiB  
Review
Ventricular Tachycardia Ablation Guided by Functional Substrate Mapping: Practices and Outcomes
by Sara Vázquez-Calvo, Ivo Roca-Luque and Andreu Porta-Sánchez
J. Cardiovasc. Dev. Dis. 2022, 9(9), 288; https://0-doi-org.brum.beds.ac.uk/10.3390/jcdd9090288 - 30 Aug 2022
Cited by 3 | Viewed by 2681
Abstract
Catheter ablation of ventricular tachycardia has demonstrated its important role in the treatment of ventricular tachycardia in patients with structural cardiomyopathy. Conventional mapping techniques used to define the critical isthmus, such as activation mapping and entrainment, are limited by the non-inducibility of the [...] Read more.
Catheter ablation of ventricular tachycardia has demonstrated its important role in the treatment of ventricular tachycardia in patients with structural cardiomyopathy. Conventional mapping techniques used to define the critical isthmus, such as activation mapping and entrainment, are limited by the non-inducibility of the clinical tachycardia or its poor hemodynamic tolerance. To overcome these limitations, a voltage mapping strategy based on bipolar electrograms peak to peak analysis was developed, but a low specificity (30%) for VT isthmus has been described with this approach. Functional mapping strategy relies on the analysis of the characteristics of the electrograms but also their propagation patterns and their response to extra-stimulus or alternative pacing wavefronts to define the targets for ablation. With this review, we aim to summarize the different functional mapping strategies described to date to identify ventricular arrhythmic substrate in patients with structural heart disease. Full article
(This article belongs to the Special Issue Catheter Ablation of Cardiac Arrhythmias: Practices and Outcomes)
Show Figures

Figure 1

14 pages, 3598 KiB  
Review
Ethanol Infusion of Vein of Marshall for the Treatment of Persistent Atrial Fibrillation: The Basics and Clinical Practice
by Bo He, Fang Zhao, Wenxi Yu, Yi Li, Xiaoyan Wu and Zhibing Lu
J. Cardiovasc. Dev. Dis. 2022, 9(8), 270; https://0-doi-org.brum.beds.ac.uk/10.3390/jcdd9080270 - 16 Aug 2022
Cited by 1 | Viewed by 2041
Abstract
Catheter ablation for persistent atrial fibrillation (PeAF) is particularly challenging, as the clinical outcomes are modest. Pulmonary vein isolation (PVI) plus linear ablation is one of the main strategies for PeAF ablation. Completely durable transmural lesions are difficult to achieve by catheter ablation [...] Read more.
Catheter ablation for persistent atrial fibrillation (PeAF) is particularly challenging, as the clinical outcomes are modest. Pulmonary vein isolation (PVI) plus linear ablation is one of the main strategies for PeAF ablation. Completely durable transmural lesions are difficult to achieve by catheter ablation during mitral isthmus ablation. The ligament of Marshall contains the vein of Marshall (VOM), myocardial tracts and innervation, and serves as arrhythmogenic foci that make it an attractive target in catheter ablation of atrial fibrillation. Additionally, it co-localizes with the mitral isthmus, and may serve as a part of the perimitral isthmus reentrant circuit. Ethanol infusion into the VOM results in rapid ablation of the neighboring myocardium and its innervation. Its incorporation into PVI significantly increases the success rate of mitral isthmus block and the clinical outcome of PeAF ablation. Full article
(This article belongs to the Special Issue Catheter Ablation of Cardiac Arrhythmias: Practices and Outcomes)
Show Figures

Figure 1

Other

Jump to: Research, Review

5 pages, 3270 KiB  
Case Report
Complete Atrioventricular Block Caused by Retrograde Transaortic Approach
by Songwen Chen, Xiaofeng Lu, Qitong Zhang, Yong Wei, Genqing Zhou and Shaowen Liu
J. Cardiovasc. Dev. Dis. 2022, 9(9), 293; https://0-doi-org.brum.beds.ac.uk/10.3390/jcdd9090293 - 03 Sep 2022
Cited by 1 | Viewed by 1290
Abstract
A 61-year-old female was referred for catheter ablation of symptomatic and frequent premature ventricular complexes presented with right bundle branch block and a prominent inferior frontal plane QRS axis. A retrograde transaortic approach was routinely performed. A sustained complete atrioventricular block was repeatedly [...] Read more.
A 61-year-old female was referred for catheter ablation of symptomatic and frequent premature ventricular complexes presented with right bundle branch block and a prominent inferior frontal plane QRS axis. A retrograde transaortic approach was routinely performed. A sustained complete atrioventricular block was repeatedly encountered while the ablation catheter was attempting to cross the aortic valve with different curves and manipulations. The procedure was abandoned. The mechanical atrioventricular block could only have been caused by the retrograde transaortic approach. We should be cautious when performing a retrograde transaortic catheter manipulation in some patients. Full article
(This article belongs to the Special Issue Catheter Ablation of Cardiac Arrhythmias: Practices and Outcomes)
Show Figures

Figure 1

10 pages, 1331 KiB  
Systematic Review
Association of Catheter Ablation and Reduced Incidence of Dementia among Patients with Atrial Fibrillation during Long-Term Follow-Up: A Systematic Review and Meta-Analysis of Observational Studies
by Andrea Saglietto, Andrea Ballatore, Henri Xhakupi, Gaetano Maria De Ferrari and Matteo Anselmino
J. Cardiovasc. Dev. Dis. 2022, 9(5), 140; https://0-doi-org.brum.beds.ac.uk/10.3390/jcdd9050140 - 30 Apr 2022
Cited by 9 | Viewed by 2415
Abstract
Background: Atrial fibrillation (AF) is independently associated with the onset of cognitive decline/dementia. AF catheter ablation (AFCA) is the most effective treatment strategy in terms of sinus rhythm maintenance, but its effects on dementia prevention remain under investigation. The aim of the present [...] Read more.
Background: Atrial fibrillation (AF) is independently associated with the onset of cognitive decline/dementia. AF catheter ablation (AFCA) is the most effective treatment strategy in terms of sinus rhythm maintenance, but its effects on dementia prevention remain under investigation. The aim of the present study was to perform a systematic review and meta-analysis of the presently available studies exploring the effect of AFCA on dementia occurrence. Methods: PubMed/MEDLINE databases were screened for articles through 14 March 2022 reporting adjusted time-to-event outcome data comparing AFCA and non-AFCA cohorts in terms of de novo dementia occurrence. A random effect meta-analysis was performed to estimate the meta-analytic hazard ratio (HR) of dementia occurrence in AFCA vs. non-AFCA cohorts, as well as the meta-analytic incidence rate of dementia in the non-AFCA cohort. Based on the aforementioned estimates, the number needed to treat (NNT), projected at median follow-up, was derived. Results: Four observational studies were included in the analysis, encompassing 40,146 patients (11,312 in the AFCA cohort; 28,834 in the non-AFCA cohort). AFCA conferred a significant protection to the development of dementia with an overall HR of 0.52 (95% CI 0.35–0.76). The incidence rate of dementia in the non-AFCA group was 1.12 events per 100 person-year (95% CI 0.47–2.67). The derived NNT projected to the median follow-up (4.5 years) was 41. Conclusion: AFCA is associated with a nearly 50% reduction in dementia occurrence during a median 4.5-year follow-up. Future randomized clinical trials are needed to reinforce these findings. Full article
(This article belongs to the Special Issue Catheter Ablation of Cardiac Arrhythmias: Practices and Outcomes)
Show Figures

Figure 1

5 pages, 1534 KiB  
Case Report
Pediatric Left Posteroseptal Accessory Pathway Ablation from Giant Coronary Sinus with Persistent Left Superior Cava
by José Cruzalegui, Sergi Cesar, Oscar Campuzano, Victoria Fiol, Josep Brugada and Georgia Sarquella-Brugada
J. Cardiovasc. Dev. Dis. 2022, 9(4), 109; https://0-doi-org.brum.beds.ac.uk/10.3390/jcdd9040109 - 06 Apr 2022
Viewed by 2182
Abstract
We report a pediatric patient with persistent left superior vena cava and a D-transposition of great arteries, which is an uncommon relation. It is crucial to know the anatomy of the persistent left superior vena cava and the dilated coronary sinus to plan [...] Read more.
We report a pediatric patient with persistent left superior vena cava and a D-transposition of great arteries, which is an uncommon relation. It is crucial to know the anatomy of the persistent left superior vena cava and the dilated coronary sinus to plan the mapping techniques in cases of posterior accessory pathways. Full article
(This article belongs to the Special Issue Catheter Ablation of Cardiac Arrhythmias: Practices and Outcomes)
Show Figures

Figure 1

Back to TopTop