materials-logo

Journal Browser

Journal Browser

Advanced Materials and Techniques in Oral Implantology

A special issue of Materials (ISSN 1996-1944). This special issue belongs to the section "Biomaterials".

Deadline for manuscript submissions: closed (31 December 2021) | Viewed by 6708

Special Issue Editors


E-Mail Website
Guest Editor
Department of Medical, Surgical and Health Sciences, University of Trieste, 34129 Trieste, Italy
Interests: oral implantology; maxillary sinus floor elevation; bone regeneration
Special Issues, Collections and Topics in MDPI journals

E-Mail Website
Guest Editor
University of Modena and Reggio Emilia, Modena, Italy
Secretary of the International Piezoelectric Surgery Academy (IPA) Via Cavallotti 134/a, 41049 Sassuolo (MO), Italy
Interests: oral implantology; maxillary sinus floor elevation; periodontal surgery

Special Issue Information

Dear Colleagues,

Multidisciplinary integration is necessary to achieve effective and predictable outcomes in every field of medicine. Oral implantology, periodontology, oral surgery, prosthesis, and materials science are strongly interconnected research fields. These disciplines have significantly evolved in recent years: improvements in implant macro- and microdesign, and new bone substitute characteristics have been proposed to meet specific functional and biological requirements.

We invite authors to submit original research articles about new biomaterials and techniques applied to the interconnected fields of oral implantology, periodontology, oral surgery, prosthesis, and materials science. Systematic reviews and meta-analyses are also welcome if they provide new sound scientific evidence in these fields.

Potential topics include but are not limited to the following:

  • New biomaterials and/or grafting techniques for bone regeneration;
  • New biomaterials and/or techniques for peri-implant soft tissue management;
  • New dental implant macro- and microdesigns for the improvement of osseointegration;
  • New technologies to avoid implant corrosion or degradation;
  • New concepts on microbiota biofilm control around dental implants.

We hope that new ideas will promote a fast development of these exciting topics, and we invite you to submit to this Special Issue the best of your research activities.

Prof. Claudio Stacchi
Dr. Sergio Spinato
Guest Editors

Manuscript Submission Information

Manuscripts should be submitted online at www.mdpi.com by registering and logging in to this website. Once you are registered, click here to go to the submission form. Manuscripts can be submitted until the deadline. All submissions that pass pre-check are peer-reviewed. Accepted papers will be published continuously in the journal (as soon as accepted) and will be listed together on the special issue website. Research articles, review articles as well as short communications are invited. For planned papers, a title and short abstract (about 100 words) can be sent to the Editorial Office for announcement on this website.

Submitted manuscripts should not have been published previously, nor be under consideration for publication elsewhere (except conference proceedings papers). All manuscripts are thoroughly refereed through a single-blind peer-review process. A guide for authors and other relevant information for submission of manuscripts is available on the Instructions for Authors page. Materials is an international peer-reviewed open access semimonthly journal published by MDPI.

Please visit the Instructions for Authors page before submitting a manuscript. The Article Processing Charge (APC) for publication in this open access journal is 2600 CHF (Swiss Francs). Submitted papers should be well formatted and use good English. Authors may use MDPI's English editing service prior to publication or during author revisions.

Keywords

  • oral implantology
  • bone augmentation
  • biomaterials
  • peri-implant soft tissue management

Published Papers (3 papers)

Order results
Result details
Select all
Export citation of selected articles as:

Research

13 pages, 2784 KiB  
Article
Autologous Platelet Gel (APG): A Preliminary Evaluation of the Mechanical Properties after Activation with Autologous Thrombin and Calcium Chloride
by Antonio Scarano, Calogero Bugea, Lucia Leo, Pablo Santos de Oliveira and Felice Lorusso
Materials 2021, 14(14), 3941; https://0-doi-org.brum.beds.ac.uk/10.3390/ma14143941 - 14 Jul 2021
Cited by 2 | Viewed by 1693
Abstract
The tensional and mechanical behavior of regenerative components, grafts, and blood clots represent an essential condition for the success of bone regeneration protocols. Autologous platelet growth factors represent a useful protocol to enhance the soft and hard tissue healing in several fields of [...] Read more.
The tensional and mechanical behavior of regenerative components, grafts, and blood clots represent an essential condition for the success of bone regeneration protocols. Autologous platelet growth factors represent a useful protocol to enhance the soft and hard tissue healing in several fields of medicine and craniofacial surgery. Different protocols for blood concentrates with and without activation have been proposed in literature. The aim of the present study was to investigate in vitro the mechanical properties of autologous platelet gel (APG) with autologous thrombin and calcium chloride. Materials and Methods: A total of 20 APG samples were evaluated; 10 samples were activated by autologous thrombin and calcium chloride (Group I) and 10 samples were non-activated (Group II). The tensile strength and modulus of elasticity were calculated through a static loading test (Lloyd 30 K, Lloyd Instruments Ltd., Segensworth, UK). Results: Group I (activated) reported a tensile strength of 373.5 ± 14.3 MPa, while Group II showed a significantly lower value of 360.5 ± 16.3 MPa (p < 0.05). The Young’s modulus was 145.3 ± 10.4 MPa for Group I and 140.3 ± 15.3 MPa for Group II (p < 0.05). Conclusions: The effectiveness of the present in vitro simulation showed that the APG activation protocol is able to increase the mechanical characteristics of the blood derivates and could be clinically useful to enhance regenerative procedures. Full article
(This article belongs to the Special Issue Advanced Materials and Techniques in Oral Implantology)
Show Figures

Figure 1

9 pages, 1192 KiB  
Article
Piezoelectric Implant Site Preparation: Influence of Handpiece Movements on Temperature Elevation
by Luca Lamazza, Marco Lollobrigida, Iole Vozza, Luigi Palmieri, Claudio Stacchi, Teresa Lombardi and Alberto De Biase
Materials 2020, 13(18), 4072; https://0-doi-org.brum.beds.ac.uk/10.3390/ma13184072 - 14 Sep 2020
Cited by 3 | Viewed by 1807
Abstract
Piezoelectric devices are widely used in oral surgical procedures, including implant site preparation. However, little is known about the influence of working movement on temperature elevation in bone. The aim of this study was to assess the effects of two different working cycles [...] Read more.
Piezoelectric devices are widely used in oral surgical procedures, including implant site preparation. However, little is known about the influence of working movement on temperature elevation in bone. The aim of this study was to assess the effects of two different working cycles on temperature elevation during piezoelectric implant site preparation. Sixty osteotomies at a depth of 10 mm were performed on bone blocks of bovine ribs using a piezoelectric tip with external irrigation (IM1s, Mectron Medical Technology, Carasco, Italy). A mechanical positioning device was used to guarantee reproducible working and measuring conditions. Two different working cycles, of 4 and 6 s, respectively, were tested, including both longitudinal and rotational movements. Temperature was recorded in real time with a fiber optic thermometer and applied pressure was maintained under 150 g. For each test, the highest recorded temperature (Tmax) and the mean temperature recorded from 30 s before to 30 s after the highest recorded temperature (T±30) were extrapolated. Tests duration was also recorded. Both Tmax and T±30 were significantly higher in the ‘6 s cycles’ group than the ‘4 s cycles’ group (42.44 ± 7.3 °C vs. 37.24 ± 4.6 °C, p = 0.002; 37.24 ± 4.6 °C vs. 33.30 ± 3.3 °C, p = 0.003). Test duration was also significantly higher using 6 s cycles compared to 4 s cycles (143.17 ± 29.4 s vs. 119.80 ± 36.4 s, p = 0.002). The results of this study indicate that working cycles of 4 s effectively reduce heat generation and working time during piezoelectric implant site preparation. Full article
(This article belongs to the Special Issue Advanced Materials and Techniques in Oral Implantology)
Show Figures

Figure 1

12 pages, 1606 KiB  
Article
Five Degree Internal Conical Connection and Marginal Bone Stability around Subcrestal Implants: A Retrospective Analysis
by Diego Lops, Michele Stocchero, Jason Motta Jones, Alessandro Freni, Antonino Palazzolo and Eugenio Romeo
Materials 2020, 13(14), 3123; https://0-doi-org.brum.beds.ac.uk/10.3390/ma13143123 - 13 Jul 2020
Cited by 8 | Viewed by 2537
Abstract
Background: There is limited information on the effect of the connection between subcrestally placed implants and abutments on marginal bone levels. The aim of the present retrospective study was to evaluate marginal bone levels after definitive prosthesis delivery around implants with an internal [...] Read more.
Background: There is limited information on the effect of the connection between subcrestally placed implants and abutments on marginal bone levels. The aim of the present retrospective study was to evaluate marginal bone levels after definitive prosthesis delivery around implants with an internal 5° conical connection placed in a subcrestal position. Materials and methods: Patients treated with fixed prostheses supported by implants placed at a subcrestal level between 2012 and 2018 were recalled for a follow-up examination. All implants had 5° internal conical connection with platform switching. Radiographic marginal bone level (MBL) was measured. MBL change between prosthetic delivery (t0) and follow-up examination (t1) was calculated. A multiple regression model was performed to identify the most significant predictors on MBL change. Results: Ninety-three patients and 410 implants, with a mean follow-up of 2.72 ± 1.31 years, were examined. Mean MBL was −1.09 ± 0.65 mm and −1.00 ± 0.37 mm at t0 and t1, respectively, with a mean bone remodeling of 0.09 ± 0.68 mm. An implant’s vertical position in relation to the bone crest, the year of follow up and the presence of type-2 controlled diabetes were demonstrated to be influencing factors for MBL modifications. Conclusions: Subcrestally placed implants with platform switching and internal conical connection maintained stable bone levels over a mean follow-up of more than 2 years. How a tight internal conical connection between abutment and implant may contribute to this clinical evidence should be more deeply investigated. MBL variations seem to be mostly influenced by an implant’s vertical position and presence of type-2 controlled diabetes. Full article
(This article belongs to the Special Issue Advanced Materials and Techniques in Oral Implantology)
Show Figures

Figure 1

Back to TopTop