Next Article in Journal
Biochemical Characterization and In Vitro Digestibility of Protein Isolates from Hemp (Cannabis sativa L.) By-Products for Salmonid Feed Applications
Next Article in Special Issue
The Difference of Volatile Compounds in Female and Male Buds of Trichosanthes anguina L. Based on HS-SPME-GC-MS and Multivariate Statistical Analysis
Previous Article in Journal
Compositions and Biological Activities of Pomegranate Peel Polyphenols Extracted by Different Solvents
Previous Article in Special Issue
Online In-Tube Solid-Phase Microextraction Coupled with Liquid Chromatography–Tandem Mass Spectrometry for Automated Analysis of Four Sulfated Steroid Metabolites in Saliva Samples
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

In Vitro and In Vivo Human Body Odor Analysis Method Using GO:PANI/ZNRs/ZIF−8 Adsorbent Followed by GC/MS

Department of Chemistry, Seoul Women’s University, 621 Hwarang-ro, Nowon-gu, Seoul 01797, Korea
*
Author to whom correspondence should be addressed.
Submission received: 30 April 2022 / Revised: 10 July 2022 / Accepted: 14 July 2022 / Published: 27 July 2022
(This article belongs to the Special Issue Solid-Phase Microextraction and Related Techniques in Bioanalysis)

Abstract

:
Among various volatile organic compounds (VOCs) emitted from human skin, trans-2-nonenal, benzothiazole, hexyl salicylate, α-hexyl cinnamaldehyde, and isopropyl palmitate are key indicators associated with the degrees of aging. In our study, extraction and determination methods of human body odor are newly developed using headspace-in needle microextraction (HS-INME). The adsorbent was synthesized with graphene oxide:polyaniline/zinc nanorods/zeolitic imidazolate framework-8 (GO:PANI/ZNRs/ZIF−8). Then, a wire coated with the adsorbent was placed into the adsorption kit to be directly exposed to human skin as in vivo sampling and inserted into the needle so that it was able to be desorbed at the GC injector. The adsorption kit was made in-house with a 3D printer. For the in vitro method, the wire coated with the adsorbent was inserted into the needle and exposed to the headspace of the vial. When a cotton T-shirt containing body odor was transferred to a vial, the headspace of the vial was saturated with body odor VOCs. After volatile organic compounds were adsorbed in the dynamic mode, the needle was transferred to the injector for analysis of the volatile organic compounds by gas chromatography/mass spectrometry (GC/MS). The conditions of adsorbent fabrication and extraction for body odor compounds were optimized by response surface methodology (RSM). In conclusion, it was able to synthesize GO:PANI/ZNRs/ZIF−8 at the optimal condition and applicable to both in vivo and in vitro methods for body odor VOCs analysis.

1. Introduction

Human body odor is a mixture of compounds generated by skin bacteria resulting in volatile organic compounds (VOCs) such as alcohol, aldehyde, acid, amine, hydrocarbons, and so on [1,2,3,4,5,6]. The primary body odor, which is distinguishable from others, is very unique in individuals that vary with age, gender, ethnic, body parts, and so on [1,5]. It can be important in areas of medical, security, safety, and cosmetic applications. On the basis of the literature, body odor VOCs carry age-related information and can be analyzed by various methods [1,6,7,8,9]. Previous studies have shown that trans-2-nonenal, benzothiazole, and isopropyl palmitate are commonly found in the elderly [1,7,8], while hexyl salicylate and α-hexyl cinnamaldehyde occur more frequently in young people [7]. In particular, trans-2-nonenal is known to be secreted more as ω7 unsaturated fatty acids are oxidized due to the increase of ω7 unsaturated fatty acids and lipid peroxides as skin aging progresses [1]. In addition, reactive oxygen species (ROS) generated by ultraviolet rays may also react with unsaturated fatty acids to affect the generation of body odor [9].
Organic solvents, gauze, solid phase microextraction (SPME) fiber, and stir bar have been used to extract human body odor [6,10,11,12]. The SPME method has been commonly used to avoid using organic solvents. There are two methods for analyzing body odor with SPME: in vivo and in vitro [13]. In both methods, target compounds are absorbed onto SPME fiber and then thermally desorbed and analyzed by gas chromatography/mass spectrometry (GC/MS). In the in vitro method, a cotton swab or T-shirt that has absorbed body odor is transferred to a SPME vial and extracted with SPME fiber. The in vivo method is a method to directly extract body odor by installing the SPME device on the skin [13]. However, it is quite inconvenient because of a glass funnel that fasten the SPME device on the skin. To address these limitations, a new method of body odor analysis has been developed by in-needle microextraction (INME) using graphene oxide:polyaniline/zinc nanorods/zeolitic imidazolate framework-8 (GO:PANI/ZNRs/ZIF−8) adsorbent. The in-needle microextraction (INME) technique has been used for extraction of volatile organic compounds in various matrix due to easy fabrication and cost effectiveness [14,15,16,17,18,19,20]. The adsorbent has been synthesized with various polarity based on polyaniline modified by additives such as multiwall carbon nanotube and ionic liquid [14,19]. The adsorbent containing analytes was desorbed by gas chromatograph/mass spectrometer (GC/MS) for qualitative and quantitative analyses.
INME has an adsorbent inside the needle and is used for solid dynamic microextraction. INME uses the needle coated with the adsorbent inside or the wire coated with adsorbent being inserted inside of the needle for extraction and analysis without using solvents followed by chromatographic analysis [14,15,16,17,18,19,20]. Especially, dynamic headspace-INME (HS-INME) has been applied to the sample by exposing the INME needle with a pump to the headspace of the vial saturated with VOCs. Polymeric adsorbents have been synthesized by sol–gel reaction [15,17,19] and/or electrochemical deposition methods [14,16,18]. It has demonstrated that INME could be customized due to easy fabrication of adsorbent and economically feasible to extract target compounds without using solvents.
The objective of this study is to fabricate GO:PANI:ZNRs:ZIF−8 adsorbent and utilize this for direct extraction of the body odor from human skin in vivo and for indirect extraction from the media adsorbed with body odor in vitro, followed by GC/MS. The mixing ratio of ZNRs and ZIF−8 of the adsorbent was varied to optimize the adsorption by modifying polarity [21]. Porous GO:PANI can be easily coated onto stainless-steel wire from the electrochemical method, while ZNRs exhibit good affinity with polar compounds and ZIF−8 with polar compounds [21,22]. Characterization of the adsorbent was measured by Fourier-transform infrared spectroscopy (FTIR), Thermogravimetric Analyzer (TGA), X-ray diffractometer (XRD), Brunauer–Emmett–Teller (BET) surface area method, and field emission-scanning electron microscopy (FE-SEM). Fabrication and extraction conditions were optimized by the Box-Behnken design (BBD) combined with response surface methodology (RSM), and the developed method was validated including limit of detection (LOD), limit of quantification (LOQ), recovery, and reproducibility.

2. Materials and Methods

2.1. Chemicals and Instrumentation

Five target compounds (Supplementary Materials Table S1), trans-2-nonenal (97%), benzothiazole (96%), hexyl salicylate (99%), α-hexyl cinnamaldehyde (85%), and isopropyl palmitate (90%), were obtained from Sigma-Aldrich (St. Louis, MO, USA). Stock solution of all target compounds was prepared using methanol (HPLC grade, Samchun Pure Chemical Co., Pyeongtaek, Korea) at a concentration of 1000 mg L−1. Stainless-steel wire (0.22 mm O.D., 09 one Science, Goyang, Korea) was used as an adsorbent wire and a working electrode. A Hamilton 91022 needle (metal hub, 22 gauge, 718 μm O.D., 413 μm I.D., bevel tip, 51 mm length) and 1 mL Hamilton 1001 TLL (gas tight syringe, luer lock gas tight syringe barrel, Reno, NV, USA) with plunger (polytetrafluoroethylene, Reno, NV, USA) were used for INME adsorption and GC/MS thermal desorption. Chemicals used in fabrication of adsorbent was shown in the supporting information.
Agilent 6970 gas chromatograph (GC) with a 5973 mass selective detector (MS) was used to analyze target compounds. HP-5MS (30 m × 0.25 mm × 0.25 μm, (5%-phenyl)-methylpolysiloxane) was used as the column and helium with the flow rate of 1 mL min−1 as the carrier gas. The injector temperature was 240 °C using split mode (30:1), and the oven program was 60 °C (4 min) to 230 °C (10 min) at 6 °C min−1. The range of 50~350 m/z was scanned in full scan mode.
Adsorbent fixing part and cover of the adsorption kit were 3D printed on a Cubicon Single Plus (3DP-310F) with polylactic acid (PLA)-plus filament.

2.2. Fabrication of Wire Coated with Adsorbent

The adsorbent was prepared in 3 steps: (1) fabrication of GO:PANI layer, (2) fabrication of GO:PANI/ZNRs layer, and (3) fabrication of GO:PANI/ZNRs/ZIF−8 layer, as illustrated in Figure 1.
GO:PANI layer was fabricated on stainless-steel wire using cyclic voltammetry in which 0.6–1.0 V (sweeping rate of 50 mV s−1 for 30 cycles) was applied to an electrolyte containing GO and aniline in a H2SO4 (0.5 mol L−1) solvent. Three-electrode system consisting of stainless-steel wire (working electrode), Pt wire (counter electrode), and Ag/AgCl electrode (reference electrode) was used. After electrochemical deposition, the coating layer was rinsed several times using distilled water to remove unreacted chemicals. Finally, the stainless-steel wire coated with porous GO:PANI was dried at 80 °C for 0.5 h.
In the GO:PANI/ZNR fabrication step, the GO:PANI coated stainless-steel wire was dipping into an aqueous mixture of zinc nitrate hexahydrate (0.5 mol L−1) and hexamethylenetetramine (0.5 mol L−1) for 30 s and dried in 180 °C oven for 2 min. This step was repeated five times. In this process, ZnO seeds formed by OH and Zn2+ were deposited on the porous GO:PANI surface. Then, the stainless-steel wire was dipped into the aqueous mixture of zinc nitrate hexahydrate (0.05 mol L−1) and hexamethylenetetramine (0.05 mol L−1) and placed in 95 °C oven for 2 h to hydrothermally grow ZnO nanorods [22].
Finally, the stainless-steel wire coated with GO:PANI/ZNRs was dipped into a 2-MI solution (DMF:H2O = 3:1 (v/v)) and placed in 90 °C oven for 8 h [22]. In this procedure, ZIF−8 was formed by coordination bonding between 2-MI and Zn2+ on ZNRs surface. Prior to the extraction process, the adsorbent coated on stainless-steel wire was placed in a 220 °C oven for 1 h to remove impurities from the coated wires. Then, it was kept in a desiccator at room temperature until further use.

2.3. Characterization of GO:PANI/ZNRs/ZIF−8 Adsorbent

The functional groups of the adsorbent generated at each step to confirm the synthesis were measured by the Fourier-transform infrared (FT-IR) spectroscopy (Perkin Elmer Spectrometer 100, Waltham, MA, USA). The crystallinity of synthesized graphene oxide and coating layer of each synthesis step were confirmed using X-ray diffractometer (XRD, Bruker DE/D8 Advance, Bruker, Karlsruhe, Germany). The thermal stability of GO:PANI, GO:PANI/ZNRs, and GO:PANI/ZNRs/ZIF−8 were evaluated by thermogravimetric analyzer (TGA, TG209 F1 Libra, Netzsch, Selb, Germany).
The specific surface area, pore size distribution, and N2 adsorption-desorption isotherm of GO:PANI/ZNRs and GO:PANI/ZNRs/ZIF−8 were observed by the Brunauer–Emmet–Teller (BET, 3flex, Micromeritics, Norcross, GA, USA). The morphology of GO:PANI, GO:PANI/ZNRs, and GO:PANI/ZNRs/ZIF−8 was characterized using field emission-scanning electron microscope (FE-SEM, JSM-6700F, JEOL Ltd., Tokyo, Japan).

2.4. INME Process

As shown in Figure 2, extraction of the target compounds was performed by the INME method. In the preparation of the INME adsorption device, a GO:PANI/ZNRs/ZIF−8-coated stainless-steel wire was inserted vertically into a Hamilton needle and then connected to a gas tight syringe. After spiking the target compounds into the SPME vial, it was sealed with a mini-nut cap. Then, saturation was performed at 40 °C for 15 min. Next, dynamic adsorption was carried out by penetrating the needle to the headspace of the SPME vial. A homemade reciprocating pump was used at 6 cycles/min to suck the analytes saturated in the headspace inside the needle during this process. Upon completion of adsorption, the analytes were thermally desorbed from the adsorbent by placing it in a GC/MS injector and analyzed by GC/MS.

2.5. Adsorption Kit Fabrication

The body odor adsorption kit was designed to adsorb VOCs directly from the skin (Figure 3). It consists of adsorbent, adsorbent fixing part, cover, and medical tape. The adsorbent was coated on the middle section of 5.0 cm stainless-steel wire to be placed in the fixing part. An adsorbent fixing part and its cover were manufactured by a 3D printer with PLA plus filament. The adsorbent kit was made as a cylinder with a hollow in the middle and a closed top, which could collect VOCs from the skin and protect the adsorbent from external odors and impacts. In addition, the adsorbent was about 10 mm away from the skin, which could avoid contamination from dead skin cells and sweat. The adsorbent fixing part has a hole in the center of the top to insert the adsorbent. PDMS was applied on the bottom of the adsorbent fixing part to reduce skin irritation due to direct contact on skin. The adsorbent kit was assembled to conduct the experiments; insert the adsorbent into the fixing part, close the cover, put it on the skin, and attach the medical tape to fix it to the skin. After the body odor was collected for 2 h, the wire coated with adsorbent was removed from the kit, inserted into a Hamilton needle, connected to a gas tight syringe, thermally desorbed at GC/MS inlet, and the body odor components were analyzed in GC/MS system. For the feasibility test of the adsorption kit, the target compounds were spiked to the artificial silica skin, and the adsorption kit was assembled to place it and adsorbed for 2 h at 36 °C.

2.6. Optimization Using Response Surface Methodology (RSM)

In the fabrication of adsorbent, the concentrations of GO, aniline, and 2-MI that may affect adsorption amount of the target compounds were optimized using RSM. 3-factor 3-level Box BBD was used with Minitab 19 (Minitab Inc., State College, PA, USA). A total of 17 experiments were conducted randomly, as shown in Table S2. The levels and coded numbers of each factor are as follows: amount of GO (X1) was 5 mg L−1 (−1), 10 mg L−1 (0), and 15 mg L−1 (1); amount of aniline (X2) was 9.31 g L−1 (−1), 14.0 g L−1 (0), and 18.6 g L−1 (1); and amount of 2-MI (X3) was 10.26 g L−1 (−1), 102.6 g L−1 (0), and 195.0 g L−1 (1).
In addition, the 3-factor 3-level BBD was used to optimize the INME analysis condition. As shown in Table S3, total of 17 experiments were conducted randomly. Extraction temperature (X1), adsorption time (X2), and desorption time (X3) were selected as factors. The levels and coded numbers for each factor were as follows: extraction temperature (X1) was 30 °C (−1), 40 °C (0), and 50 °C (1); the adsorption time (X2) was 30 min (−1), 45 min (0), and 60 min (1); and the desorption time (X3) was 1 min (−1), 3 min (0), and 5 min (1).
The data obtained from the experiments for fabrication condition and the INME analysis conditions were analyzed by the response surface regression procedure using second-order polynomial model (Equation (1)).
Y = α 0 + α 1 X 1 + α 2 X 2 + α 3 X 3 + α 11 X 1 2 + α 22 X 2 2 + α 33 X 3 2 + α 12 X 1 X 2 + α 13 X 1 X 3 + α 23 X 2 X 3
where Y is the predicted response (amount of adsorption); α 0 is the intercept, α 1 , α 2 , and α 3 are linear coefficients; α 11 , α 22 , and α 33 are quadratic coefficients; and α 12 , α 13 , and α 23 , are the interactive coefficients.

3. Results and Discussion

3.1. Optimization of Human Body Odor Adsorbent Fabrication Conditions Using RSM

Reactants such as GO (X1), aniline (X2), and 2-MI (X3) added were optimized through RSM. It determines the optimized value of each variable and analyzes the interactions between the variables. Optimized values for each variable were obtained using the regression equation calculated using Minitab (Table 1). A three-dimensional response surface curve is a graphical representation of the results from the regression equation. In each graph, after fixing one of the three independent variables to level 0, the effect of the remaining two independent variables on peak area obtained from the total ion chromatogram (TIC) was investigated (Figure S1) [23]. Confirming the relationship between GO and aniline, the peak area value rapidly increased as aniline increased, while the peak area value increased gently as the amount of GO increased. In the relationship between GO and 2-MI, as the amount of 2-MI increased, the peak area increased rapidly except for trans-2-nonenal, and the amount of GO showed a gradual increase. In the relationship between aniline and 2-MI, the peak area increased rapidly as 2-MI increased, except for trans-2-nonenal, and the amount of aniline increased gradually. Consequently, the order affecting the peak areas is 2-MI, aniline, and GO. The optimal BBD results for the reactants are determined as 15 mg L−1 of GO, 18.3 g L−1 of aniline, and 151.6 g L−1 of 2-MI. The error of the modeling equation obtained through the BBD method was about 10%. The peak area value for each target compound can be predicted by substituting the concentration of each reactant.

3.2. Optimization of INME Extraction Conditions Using RSM

HS-INME-GO:PANI/ZNRs/ZIF−8 extraction conditions, including extraction temperature (X1), adsorption time (X2), and desorption time (X3), were optimized using the RSM method. Figure S2 is a response surface graph showing the relationship between the variables and the peak area values. In the relationship of extraction temperature and adsorption time, it was observed that the extraction temperature had a more significant effect on extraction for trans-2-nonenal and benzothiazole, while the adsorption time had a greater effect on the remaining compounds. Confirming the relationship of extraction temperature and desorption time, the extraction temperature had a greater effect than the desorption time for all target compounds. The relationship between adsorption time and desorption time was found that desorption time had a greater effect on extraction. The optimal extraction conditions based on the RSM results are as follows. The optimal condition was 40 °C for extraction temperature, 60 min for adsorption time, and 4.3 min for desorption time, respectively. The modeling equation showed an error about 10%. and the value of the peak area of each target compound could be reasonably predicted from the modeling equation (Table 2).

3.3. Characterization of the Adsorbent

The products generated at each synthesis process prepared under optimal conditions were characterized through FT-IR, TGA, XRD, BET, and FE-SEM. FT-IR spectra (Figure 4A) show that GO was well-synthesized from graphite by verifying the O-H band at 3389 cm−1, the C=O band at 1721 cm−1, the C=C band in the phenol ring at 1613 cm−1, the C-OH band at 1227 cm−1, and C-O band at 1048 cm−1 in the IR spectrum of GO [24]. Through the following peaks in the IR spectrum of GO:PANI, it was confirmed that the GO plate was covered by PANI nanofibers to form GO:PANI identified by peaks at 1561 cm−1 from C=C in quinone, 1479 cm−1 from benzene ring, 1302 cm−1 from C-N in the second amine ring, 1242 cm−1 from C-N vibrational band in the protonic acid, 1126 cm−1 from C=N vibrational band, and 805 cm−1 from the aromatic C-H band [24]. In the IR spectrum of GO:PANI/ZNRs, peaks of amine groups and benzene ring shifted to higher wavenumbers than GO:PANI from the previous synthesis step were observed at 1585 cm−1, 1498 cm−1, 1297 cm−1, 1143 cm−1, and 826 cm−1. This indicates that the amine and imine nitrogen atoms interact with Zn2+ via either protonation or complexation [25]. In addition, the O-Zn-O stretching vibration peak was observed at 432 cm−1 [26]. Amine groups and a benzene ring were observed at 1596 cm−1, 1500 cm−1, 1308 cm−1, 1148 cm−1, and 827 cm−1 in the GO:PANI/ZNRs/ZIF−8 IR spectrum. Additionally, a peak at 748 cm−1 from out of plane bending of the 2-MI ring and a 420 cm−1 peak from Zn-N stretching confirmed that the nitrogen atom was connected to 2-MI linker to form ZIF−8 [27].
From the XRD analysis, it was confirmed that ZNRs and ZIF−8 were well-formed (Figure 4B). In the GO:PANI/ZNRs, peaks at 2θ = 31.68° (100), 34.35° (002), 36.16° (101), 47.43° (012), and 56.49° (110), which are identical to the peaks from the ZnO standard, were observed. Both ZnO and ZIF−8 peaks in GO:PANI/ZNRs/ZIF−8 were confirmed to compare with peaks from the ZnO and ZIF−8 standards. Peaks observed at 2θ = 7.33° (011), 10.37° (002), 12.71° (112), 14.70° (022), 16.43° (013), 18.52° (222), 22.14° (114), 24.48° (233), and 26.61° (134) were identical to the peaks of the ZIF−8 standard, while peaks at 2θ = 31.71° (100), 34.40° (002), 36.20° (101), 47.48° (012), and 56.53° (110) were observed from the ZnO standard. It was concluded that the adsorbent consists of GO:PANI/ZNRs/ZIF−8 was well-synthesized and expected to adsorb compounds having various polarities due to various functional groups.
Thermal stability of the adsorbent synthesized at each step was measured by TGA (Figure S3). Significant weight loss was not observed and confirmed thermal stability up to 273 °C. Mass change at 81 °C is regarded as the dehydration process. The mass change of GO:PANI/ZNRs was not observed until 262 °C. The effect of GO addition on thermal stability was shown clearly to compare the decomposition temperature between PANI/ZNRs/ZIF−8 and GO:PANI/ZNRs/ZIF−8, which was 195 °C and 291 °C, relatively.
The effect of ZIF−8 addition on pore size distribution is shown in Figure 5 as the pore size distribution and N2 adsorption and desorption isotherm. The BET specific surface area of GO:PANI/ZNRs/ZIF−8 was 4640 m2 g−1, which was much higher than that of GO:PANI/ZNRs with a specific surface area of 5.35 m2 g−1. According to the pore size distribution curve, GO:PANI/ZNRs has mesopore (2~50 nm), whereas GO:PANI/ZNRs/ZIF−8 has micropore (<2 nm) and mesopore (2~50 nm) [28]. In addition, N2 adsorption and desorption isotherm of GO:PANI/ZNRs/ZIF−8 showed type I isotherm indicating that micropore and mesopore coexist [29].
The morphology of the adsorbent coated on stainless-steel wire was observed using FE-SEM in Figure 6. The image of GO:PANI showed a rough and porous surface due to the deposition of PANI nanofibers on the GO sheets [24]. In GO:PANI/ZNRs image, flower-shaped ZnO nanostructures were constructed on the porous GO:PANI. Rhombic dodecahedron ZIF−8 was observed in GO:PANI/ZNRs/ZIF−8 image, which indicates that ZIF−8 was well-dispersed on the ZNRs surface of GO:PANI/ZNRs [30].
Comparing the adsorption amount by each synthesized step and PANI/ZNRs/ZIF−8, GO:PANI/ZNRs/ZIF−8 shows the highest adsorption for all target compounds (Figure S4). The final adsorbent has moieties with different polarities from ZNRs and ZIF−8 to enhance the adsorption potentials, and its large specific surface area and micropores might play an important role in increasing the adsorption amounts. Strong π–π stacking interaction and hydrogen bonding between target compounds and adsorbent contribute to the improved extraction of target compounds [22,23]. In comparison between GO:PANI/ZNRs/ZIF−8 and PANI/ZNRs/ZIF−8, GO addition tends to increase the adsorption amount of trans-2-nonenal that appears to interact between GO and C=O of trans-2-nonenal.
Based on the literature reviews, there are few studies on GO:PANI/ZNRs/ZIF−8 adsorbent for the human body odor compounds. On the other hand, the adsorbents composed of GO, PANI, ZNRs, and ZIF−8 as SPME fibers coupled with chromatography have been studied in water, soil, air, and food samples [21,22,24,27,28]. The GO:PANI was used as an effective adsorbent for Zn ion removal from the water sample [24]. The adsorbent of zinc oxide nanorods directly coated on stainless-steel wire was applied as SPME fiber to extract aldehydes for instant noodle samples [21]. Hexanal, heptanal, octanal, nonanal, and decanal were analyzed with a linear range between 0.08 and 5.0 μg g−1 [21]. PANI/ZNRs/ZIF−8 was synthesized to extract 2-methylnaphthalene, 1-methylnaphthalene, pyrene, phenanthrene, cyrysene, and benzo[a]pyrene of polycyclic aromatic hydrocarbons (PAHs) in a sewage water sample [22]. The synthesized ZIFs-ZnO composite as a sorbent for SPME-HPLC-UV was used to remove Sudan dyes in the water sample showing 0.002 ng mL−1 LOD and wide linear ranges 0.02–20 ng mL−1 [27].

3.4. Comparison of Extraction Efficiency

The Dynamic INME and static INME method were compared by enrichment factor (EF). EF was calculated as follows:
EF = A1/A0
A1 is the peak area from dynamic INME method that sucks the target compounds inside the needle using a reciprocating pump, and A0 is the peak are from the static INME method that was performed without using a pump. The EF value of trans-2-nonenal was 1062.29 ± 33.72, benzothiazole was 390.12 ± 73.14, hexyl salicylate was 29.71 ± 5.41, α-hexyl cinnamaldehyde was 36.79 ± 1.30, and isopropyl palmitate was 1.54 ± 0.59, respectively. It was concluded that all target compounds were more efficiently extracted than the static INME- method.

3.5. Feasibility Test Using an Adsorption Kit

The body odor adsorption kit developed in this study was applied to in vivo sampling. A feasibility test was performed on petri dish spiking 30 μg target compounds to place an adsorption kit fixed with the medical tape.
After 2 h exposure to compounds, the wire coated with GO:PANI/ZNRs/ZIF−8 adsorbent inserted inside the adsorption kit was removed, put into the Hamilton needle, and connected to the plunger to desorb the compounds at GC/MS injector. The TIC obtained from this process is shown in Figure 7. From TIC, all five target compounds were well-separated and measured. trans-2-Nonenal, benzothiazole, hexyl salicylate, α-hexyl cinnamaldehyde, and isopropyl palmitate were successfully separated at the retention time of 12.45 min, 14.42 min, 24.15 min, 25.40 min, and 29.92 min, respectively. In conclusion, the body odor adsorption kit developed in this study could be used as an in vivo sampling method for human body odor analysis.

3.6. Method Validation

The INME method for in vitro body odor extraction was validated by analyzing five target compounds repeatedly. For all target compounds, the linearity of the seven-points calibration curves had r2 values greater than 0.99 in the dynamic range. Limit of detection (LOD) and limit of quantitation (LOQ) were calculated according to ISO definition [31]. The calculated LOD and LOQ were 4.89 ng~128 ng and 14.8 ng~38.8 ng, respectively. The dynamic range was 4.89 ng~15,000 ng.
Recovery = (AC + AI) − A0/AS × 100
In addition, a recovery test was performed by analyzing a 100% cotton T-shirt with an analyte spiked by the proposed method (Figure 8). The recovery rate was calculated using Equation (3), that AC is the amount of target compounds adsorbed on the 100% cotton T-shirt, AI is the amount of target compounds adsorbed on GO:PANI/ZNRs/ZIF−8 adsorbent using HS-INME method, A0 is the amount of target compounds in the unspiked sample, and AS is the amount of target compounds spiked on the 100% cotton T-shirt [19]. The recovery rate shows acceptable values, ranging from 91.27% to 103.47%.
The reproducibility of the proposed method was confirmed by obtaining the relative standard deviation of intra assay (run to run, n = 5) and inter assay (needle to needle, n = 5). As a result, in the intra and inter assays, all target compounds showed about 10% and 15% precision, respectively.

4. Conclusions

In this study, in vitro and in vivo methods using GO:PANI/ZNRs/ZIF−8 adsorbent that were suitable for body odor adsorption was developed. The amounts of GO, aniline, and 2-MI added during the adsorbent fabrication process were simply and accurately optimized through the RSM method determined as 15 mg L−1 of GO, 18.3 g L−1 of aniline, and 151.6 g L−1 of 2-MI, respectively. The physicochemical characterization of the synthesized adsorbent was confirmed by FT-IR, XRD, TGA, BET, and SEM. The large surface area and micropore of the adsorbent increased the adsorption amount of the target compounds, and the thermal stability was increased due to the addition of GO. In in vivo sampling, a wire coated with adsorbent could be placed directly to the human skin using an adsorbent kit developed in this study. In in vitro method, a wire coated with GO:PANI/ZNRs/ZIF−8 to be used as dynamic HS-INME method to adsorb human body odor VOCs saturated in the headspace of the vial. As a result of the validation of the in vitro method, analysis of aging-related human body odor compounds was successfully performed with good precision and recovery. GO:PANI/ZNRs/ZIF−8 adsorbent could be used as INME method that could adsorb five aging-related human body odor compounds successfully and demonstrate over 100 applications after the conditioning process.

Supplementary Materials

The following supporting information can be downloaded at https://0-www-mdpi-com.brum.beds.ac.uk/article/10.3390/molecules27154795/s1: Figure S1: Response surface diagrams of target compounds by factors.; Figure S2: Response surface diagrams of target compounds by factors. Figure S3: TGA curves of GO:PANI, GO:PANI/ZNRs, GO:PANI/ZNRs/ZIF−8, and PANI/ZNRs/ZIF−8. Figure S4: Comparison of the adsorption amount of five target compounds according to the adsorbent synthesis steps, and without GO. Table S1: Physicochemical properties of target compounds. Table S2: Experimental design matrix for optimization of the reactant concentrations in fabrication of adsorbent. Table S3: Experimental design matrix for optimization of HS-INME conditions.

Author Contributions

Conceptualization, S.B.; methodology, S.K.; validation, S.K. and S.B.; investigation, S.K.; writing—original draft preparation, S.K.; writing—review and editing, S.B.; and supervision, S.B. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the Korean National Research Foundation, grant number (2020R1A2C1014112), and Seoul Women’s University (2022-0081).

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Informed consent was obtained from all subjects involved in the study.

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.

Sample Availability

Samples of the compounds are not available from the authors.

References

  1. Haze, S.; Gozu, Y.; Nakamura, S.; Kohno, Y.; Sawano, K.; Ohta, H.; Yamazaki, K. 2-NonenalNewly Found in Human Body Odor Tends to Increase with Aging. J. Investig. Dermatol. 2001, 116, 520–524. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  2. Yamazaki, S.; Hoshino, K.; Kusuhara, M. Odor Associated with Aging. J. Anti-Aging Med. 2010, 7, 60–65. [Google Scholar] [CrossRef] [Green Version]
  3. Ackerl, K.; Atzmueller, M.; Grammer, K. The scent of fear. Neuroendocr. Lett. 2002, 23, 79–84. [Google Scholar]
  4. Singh, D.; Bronstad, P.M. Female body odour is a potential cue to ovulation. Proc. R. Soc. B 2001, 268, 797–801. [Google Scholar] [CrossRef] [Green Version]
  5. Abaffy, T.; Möller, M.; Riemer, D.D.; Milikowski, C.; Defazio, R.A. A Case Report-olatile Metabolomic Signature of Malignant Melanoma using Matching Skin as a Control. J. Cancer Sci. Ther. 2011, 3, 140–144. [Google Scholar] [CrossRef]
  6. Jha, S.K. Characterization of human body odor and identification of aldehydes using chemical sensor. Rev. Anal. Chem. 2017, 36, 20160028. [Google Scholar] [CrossRef]
  7. Gallagher, M.; Wysocki, C.J.; Leyden, J.J.; Spielman, A.I.; Sun, X.; Preti, G. Analyses of volatile organic compounds from human skin. Br. J. Derm. 2008, 159, 780–791. [Google Scholar] [CrossRef] [Green Version]
  8. Kimura, K.; Sekine, Y.; Furukawa, S.; Takahashi, M.; Oikawa, D. Measurement of 2-nonenal and diacetyl emanating from human skin surface employing passive flux sampler—GCMS system. J. Chromatogr. B Anal. Technol. Biomed. Life Sci. 2016, 1028, 181–185. [Google Scholar] [CrossRef]
  9. Doo, H.; Won, B.; Han, J.P.; Hwang, S.J.; Kim, J.; Park, J.; Park, S.N. Antioxidative Effect and Tyrosinase Inhibitory Activity of Lindera obtusiloba Blume Extracts. J. Soc. Cosmet. Sci. Korea 2012, 38, 297. [Google Scholar]
  10. Curran, A.; Rabin, S.; Prada, P.; Furton, K. Comparison of the Volatile Organic Compounds Present in Human Odor Using Spme-GC/MS. J. Chem. Ecol. 2005, 31, 1607–1619. [Google Scholar] [CrossRef]
  11. Curran, A.M.; Ramirez, C.F.; Schoon, A.A.; Furton, K.G. The frequency of occurrence and discriminatory power of compounds found in human scent across a population determined by SPME-GC/MS. J. Chromatogr. B Analt. Technol. Biomed. Life Sci. 2007, 846, 86–97. [Google Scholar] [CrossRef]
  12. Penn, D.J.; Oberzaucher, E.; Grammer, K.; Fischer, G.; Soini, H.A.; Wiesler, D.; Novotny, M.V.; Dixon, S.J.; Xu, Y.; Brereton, R.G. Individual and gender fingerprints in human body odour. J. R. Soc. Interface 2007, 4, 331–340. [Google Scholar] [CrossRef]
  13. Jiang, R.; Cudjoe, E.; Bojko, B.; Abaffy, T.; Pawliszyn, J. A non-invasive method for in vivo skin volatile compounds sampling. Anal. Chim. Acta 2013, 804, 111–119. [Google Scholar] [CrossRef]
  14. Lee, S.Y.; Yoon, J.H.; Bae, S.; Lee, D.S. In-needle microextraction coupled with gas chromatography/mass spectrometry for the analysis of phthalates generating from food containers, Food Anal. Methods 2018, 11, 2767–2777. [Google Scholar]
  15. Jeon, H.L.; Son, H.H.; Bae, S.; Lee, D.S. Use of polyacrylic acid and polydimethylsiloxane mixture for in-needle microextraction of volatile aroma compounds in essential oils, Bull. Korean Chem. Soc. 2015, 36, 2730–2739. [Google Scholar] [CrossRef]
  16. Hwang, Y.R.; Lee, Y.L.; Ahn, S.Y.; Bae, S. Electrochemically polyaniline-coated microextraction needle for phthalates in water. Anal. Sci. Technol. 2020, 33, 76–85. [Google Scholar]
  17. Bang, Y.J.; Hwang, Y.R.; Lee, S.Y.; Park, S.M.; Bae, S. Sol–gel-adsorbent-coated extraction needles to detect volatile compounds in spoiled fish. J. Sep. Sci. 2017, 40, 3839–3847. [Google Scholar] [CrossRef]
  18. Kim, S.; Bae, S.; Lee, D.-S. Characterization of scents from Juniperus chinensis by headspace in-needle microextraction using graphene oxide-polyaniline nanocomposite coated wire followed by gas chromatography-mass spectrometry. Talanta 2022, 245, 123463. [Google Scholar] [CrossRef]
  19. Jeong, H.Y. Analysis of Age-related Volatile Organic Compounds Using INME Coated with PDMS/MWCNT followed by GC/MS. Master’s Thesis, Seoul Women’s University, Seoul, Korea, 2021. [Google Scholar]
  20. Son, H.; Bae, S.; Lee, D. New needle packed with polydimethylsiloxane having a micro-bore tunnel for headspace in-needle microextraction of aroma components of citrus oils. Anal. Chim. Acta 2012, 751, 86–93. [Google Scholar] [CrossRef]
  21. Ji, J.; Liu, H.; Chen, J.; Zeng, J.; Huang, J.; Gao, L.; Wang, Y.; Chen, X. ZnO nanorod coating for solid phase microextraction and its applications for the analysis of aldehydes in instant noodle samples. J. Chromatogr. A 2012, 1246, 22–27. [Google Scholar] [CrossRef]
  22. Zeng, J.; Li, Y.; Zheng, X.; Li, Z.; Zeng, T.; Duan, W.; Li, Q.; Shang, X.; Dong, B. Controllable Transformation of Aligned ZnO Nanorods to ZIF−8 as Solid-Phase Microextraction Coatings with Tunable Porosity, Polarity, and Conductivity. Anal. Chem. 2019, 91, 5091–5097. [Google Scholar] [CrossRef]
  23. Park, H.E.; Ho, K. Optimization of Synthesis Condition of Monolithic Sorbent Using Response Surface Methodology. Appl. Chem. Eng. 2013, 24, 299–304. [Google Scholar]
  24. Ramezanzadeh, M.; Asghari, M.; Ramezanzadeh, B.; Bahlakeh, G. Fabrication of an efficient system for Zn ions removal from industrial wastewater based on graphene oxide nanosheets decorated with highly crystalline polyaniline nanofibers (GO-PANI): Experimental and ab initio quantum mechanics approaches. Chem. Eng. J. 2018, 337, 385–397. [Google Scholar] [CrossRef]
  25. Brožová, L.; Holler, P.; Kovářová, J.; Stejskal, J.; Trchová, M. The stability of polyaniline in strongly alkaline or acidic aqueous media. Polym. Degrad. Stab. 2008, 93, 592–600. [Google Scholar] [CrossRef]
  26. Andres Verges, M.; Serna, C.J. Morphological characterization of ZnO powders by X-ray and IR spectroscopy. J. Mater. Sci. Lett. 1988, 7, 970–972. [Google Scholar] [CrossRef]
  27. Ling, X.; Chen, Z. Immobilization of zeolitic imidazolate frameworks with assist of electrodeposited zinc oxide layer and application in online solid-phase microextraction of Sudan dyes. Talanta 2019, 192, 142–146. [Google Scholar] [CrossRef]
  28. Storck, S.; Bretinger, H.; Maier, W.F. Characterization of micro- and mesoporous solids by physisorption methods and pore-size analysis. Appl. Catal. A 1998, 174, 137–146. [Google Scholar] [CrossRef] [Green Version]
  29. Xing, T.; Lou, Y.; Bao, Q.; Chen, J. Surfactant-assisted synthesis of ZIF−8 nanocrystals in aqueous solution via microwave irradiation. CrystEngComm 2014, 16, 8994–9000. [Google Scholar] [CrossRef]
  30. He, L.; Li, L.; Zhang, L.; Xing, S.; Wang, T.; Li, G.; Wu, X.; Su, Z.; Wang, C. ZIF−8 templated fabrication of rhombic dodecahedron-shaped ZnO@SiO2, ZIF−8@SiO2 yolk–shell and SiO2 hollow nanoparticles. CrystEngComm 2014, 16, 6534. [Google Scholar] [CrossRef]
  31. Wenzl, T.; Haedrich, J.; Schaechtele, A.; Robouch, P.; Stroka, J. Guidance Document on the Estimation of LOD and LOQ for Measurements in the Field of Contaminants in Feed and Food; Publications office of the European Union: Geel, Belgium, 2016; Volume 28099. [Google Scholar] [CrossRef]
Figure 1. Fabrication process of the adsorbent.
Figure 1. Fabrication process of the adsorbent.
Molecules 27 04795 g001
Figure 2. A scheme of INME process. (A) A needle inserted with a coated wire is connected to a gas tight syringe. (B) The needle was plugged into the mini-nut cap to adsorb target compounds in the headspace using a reciprocating pump. (C) The target compounds adsorbed on the adsorbent was thermally desorbed in GC injector and analyze using GC/MS.
Figure 2. A scheme of INME process. (A) A needle inserted with a coated wire is connected to a gas tight syringe. (B) The needle was plugged into the mini-nut cap to adsorb target compounds in the headspace using a reciprocating pump. (C) The target compounds adsorbed on the adsorbent was thermally desorbed in GC injector and analyze using GC/MS.
Molecules 27 04795 g002
Figure 3. (A) A schematic view of adsorption kit for the collection of body odor from human skin (the unit of length: mm). (B) Actual image of adsorbent placed on the fixing part made by 3D printer. (C) Sampling of body odor at the arm using adsorbent kit covered by a medical tape.
Figure 3. (A) A schematic view of adsorption kit for the collection of body odor from human skin (the unit of length: mm). (B) Actual image of adsorbent placed on the fixing part made by 3D printer. (C) Sampling of body odor at the arm using adsorbent kit covered by a medical tape.
Molecules 27 04795 g003
Figure 4. (A) FT-IR spectrums of graphite, GO, GO:PANI, GO:PANI/ZNRs, and GO:PANI/ZNRs/ZIF−8 and (B) XRD spectrums of the ZnO (standard), ZIF−8 (standard), GO:PANI/ZNRs/ZIF−8, and GO:PANI/ZNRs/ZIF−8.
Figure 4. (A) FT-IR spectrums of graphite, GO, GO:PANI, GO:PANI/ZNRs, and GO:PANI/ZNRs/ZIF−8 and (B) XRD spectrums of the ZnO (standard), ZIF−8 (standard), GO:PANI/ZNRs/ZIF−8, and GO:PANI/ZNRs/ZIF−8.
Molecules 27 04795 g004
Figure 5. (A) Pore width distribution of GO:PANI/ZNRs and GO:PANI/ZNRs/ZIF−8 and (B) N2 adsorption-desorption isotherms of GO:PANI/ZNRs and GO:PANI/ ZNRs/ZIF−8.
Figure 5. (A) Pore width distribution of GO:PANI/ZNRs and GO:PANI/ZNRs/ZIF−8 and (B) N2 adsorption-desorption isotherms of GO:PANI/ZNRs and GO:PANI/ ZNRs/ZIF−8.
Molecules 27 04795 g005
Figure 6. SEM images of stainless-steel wire coated with (A) GO:PANI, (B) GO:PANI/ZNRs, and (C) GO:PANI/ZNRs/ZIF−8 (1; ×5000, 2; ×20,000).
Figure 6. SEM images of stainless-steel wire coated with (A) GO:PANI, (B) GO:PANI/ZNRs, and (C) GO:PANI/ZNRs/ZIF−8 (1; ×5000, 2; ×20,000).
Molecules 27 04795 g006
Figure 7. Total ion chromatogram of aging-related body odor using adsorption kit ((1) trans-2-noenal, (2) benzothiazole, (3) hexyl salicylate, (4) a-hexyl cinnamaldehyde, and (5) isopropyl palmitate).
Figure 7. Total ion chromatogram of aging-related body odor using adsorption kit ((1) trans-2-noenal, (2) benzothiazole, (3) hexyl salicylate, (4) a-hexyl cinnamaldehyde, and (5) isopropyl palmitate).
Molecules 27 04795 g007
Figure 8. Total ion chromatogram of aging-related body odor spiked on 100% cotton T-shirt using INME method ((1) trans-2-nonenal, (2) benzothiazole, (3) hexyl salicylate, (4) a-hexyl cinnamaldehyde, and (5) isopropyl palmitate).
Figure 8. Total ion chromatogram of aging-related body odor spiked on 100% cotton T-shirt using INME method ((1) trans-2-nonenal, (2) benzothiazole, (3) hexyl salicylate, (4) a-hexyl cinnamaldehyde, and (5) isopropyl palmitate).
Molecules 27 04795 g008
Table 1. Peak area prediction formula of each material obtained through BBD in optimization of the reactant concentration.
Table 1. Peak area prediction formula of each material obtained through BBD in optimization of the reactant concentration.
CompoundModel Formula
trans-2-Nonenal1,373,897 + 65,796 X1 + 71,554 X2 − 165,521 X3 + 737,146 X12 − 307,202 X22 + 2692 X32 − 9779 X1X2 + 70,330 X1X3 − 3443 X2X3
Benzothiazole2,738,952 + 459,936 X1 + 881,137 X2 + 255,043 X3 + 1,078,534 X12 + 520,184 X22 + 591,432 X32 − 221,829 X1X2 − 241,702 X1X3 + 320,824 X2X3
Isopropyl palmitate55,849 + 10,191 X1 + 10,199 X2 + 7497 X3 − 11,547 X12 − 4503 X22 − 15,959 X32 + 3465 X1X2 + 1502 X1X3 + 3925 X2X3
Hexyl salicylate667,682 + 81,671 X1 + 81,140 X2 + 93,743 X3 + 47,534 X12 − 18,836 X22 − 27,142 X32 − 888 X1X2 + 24,879 X1X3 + 34,062 X2X3
α-Hexyl cinnamaldehyde1,127,759 + 173,707 X1 + 296,075 X2 + 229,720 X3 + 53,389 X12 + 84,526 X22 + 26,918 X32 + 150,333 X1X2 − 60,256 X1X3 + 112,567 X2X3
X1: amount of graphene oxide (mg L−1), X2: amount of aniline (g L−1), and amount of X3: 2-methyl imidazole (g L−1).
Table 2. Peak area prediction formula of each compound obtained through BBD in optimization of INME-GO:PANI/ZNRs/ZIF−8 analysis conditions.
Table 2. Peak area prediction formula of each compound obtained through BBD in optimization of INME-GO:PANI/ZNRs/ZIF−8 analysis conditions.
CompoundModel Formula
trans-2-Nonenal6,715,422 + 1,488,188 X1 + 990,247 X2 − 290,098 X3 − 154,172 X12 − 416,644 X22 + 858,182 X32 − 1,371,651 X1X2 + 379,903 X1X3 − 108,883 X2X3
Benzothiazole3,475,053 − 572,871 X1 + 578,351 X2 + 260,594 X3 + 80,741 X12 + 19,364X22 + 507,335 X32 − 1,048,215 X1X2 − 390,972 X1X3 + 686,615 X2X3
Isopropyl palmitate70,372 + 50,455 X1 + 25,337 X2 − 1915 X3 + 15,132 X12 − 7361 X22 + 20,237 X32 + 9741 X1X2 − 6146 X1X3 − 18,574 X2X3
Hexyl salicylate1,477,657 + 311,065 X1 + 284,017 X2 + 104,003 X3 − 37,787 X12 − 246,864 X22 + 85,773 X32 + 5355 X1X2 + 18,324 X1X3 + 76,669 X2X3
α-Hexyl cinnamaldehyde2,459,037 + 6,365,250 X1 + 452,391 X2 − 67,492 X3 − 291,829 X12 − 446,990 X22 + 118,680 X32 + 20,695 X1X2 − 27,709 X1X3 + 195,394 X2X3
X1: extraction temperature (°C), X2: adsorption time (min), and X3: desorption time (min).
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Kim, S.; Bae, S. In Vitro and In Vivo Human Body Odor Analysis Method Using GO:PANI/ZNRs/ZIF−8 Adsorbent Followed by GC/MS. Molecules 2022, 27, 4795. https://0-doi-org.brum.beds.ac.uk/10.3390/molecules27154795

AMA Style

Kim S, Bae S. In Vitro and In Vivo Human Body Odor Analysis Method Using GO:PANI/ZNRs/ZIF−8 Adsorbent Followed by GC/MS. Molecules. 2022; 27(15):4795. https://0-doi-org.brum.beds.ac.uk/10.3390/molecules27154795

Chicago/Turabian Style

Kim, Sehyun, and Sunyoung Bae. 2022. "In Vitro and In Vivo Human Body Odor Analysis Method Using GO:PANI/ZNRs/ZIF−8 Adsorbent Followed by GC/MS" Molecules 27, no. 15: 4795. https://0-doi-org.brum.beds.ac.uk/10.3390/molecules27154795

Article Metrics

Back to TopTop