Next Article in Journal
Developing Fair Investment Plans to Enhance Supply Chain Visibility Using Cooperative Games
Next Article in Special Issue
Strengthening of RC Structures by Using Engineered Cementitious Composites: A Review
Previous Article in Journal
A Text Mining Approach for Sustainable Performance in the Film Industry
Previous Article in Special Issue
Experimental Study on Static Mechanical Properties and Moisture Contents of Concrete Under Water Environment
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Review

Strengthening and Repair of Reinforced Concrete Columns by Jacketing: State-of-the-Art Review

1
Centre for Sustainable Infrastructure, Swinburne University of Technology, Melbourne, VIC 3122, Australia
2
School of Engineering and Information Technology, University of New South Wales, Canberra, ACT 2612, Australia
3
Bushfire & Natural Hazards Cooperative Research Centre, Melbourne, VIC 3002, Australia
*
Author to whom correspondence should be addressed.
Sustainability 2019, 11(11), 3208; https://0-doi-org.brum.beds.ac.uk/10.3390/su11113208
Submission received: 17 May 2019 / Revised: 3 June 2019 / Accepted: 4 June 2019 / Published: 9 June 2019

Abstract

:
Sustainability necessitates the protection of infrastructure from any kind of deterioration over the life cycle of the asset. Deterioration in the capacity of reinforced concrete (RC) infrastructure (e.g., bridges, buildings, etc.) may result from localised damage sustained during extreme loading scenarios, such as earthquakes, hurricanes or tsunamis. In addition, factors such as the corrosion of rebars or ageing may also deteriorate or degrade the capacity of an RC column, thereby necessitating immediate strengthening to either extend or ensure its design life is not limited. The aim of this paper is to provide a state-of-the-art review of various strengthening and repair methods for RC columns proposed by different researchers in the last two decades. The scope of this review paper is limited to jacketing techniques for strengthening and/or repairing both normal- and high-strength RC columns. The paper also identifies potential research gaps and outlines the future direction of research into the strengthening and repair of RC columns.

1. Introduction

There is an increasing focus and emphasis on the sustainability of existing infrastructure. The rehabilitation and strengthening of damaged or deficient reinforced concrete (RC) structures has the potential to restore and/or enhance the structural performance to a level required by current design codes. Rehabilitation and/or strengthening is a more sustainable solution compared to simply just demolishing and reconstructing the entire facility, from both the point of view of the conservation of resources (e.g., time, cost, materials, etc.) and the reducing the overall carbon footprint of the construction industry.
Seismic retrofitting and/or the strengthening of RC columns has been a popular area of research for decades. This is primarily because, in a building frame system or a bridge, the imposed seismic energy demand is dissipated by the displacement of the columns, thereby resulting in slight to severe damage depending on the severity of the earthquake, and hence the need for repair emerges to ensure the smooth post-earthquake recovery of the facility. Secondly, RC building structures that were designed prior to the incorporation of seismic detailing guidelines of the 1970s generally possess non-ductile RC columns, which make them inherently vulnerable during an earthquake. Strengthening techniques can be used to upgrade columns of this nature and allow them to conform to the latest code requirements. The need for strengthening and repair may also arise because of a number of other factors such as the ageing of structure, deterioration of concrete, change in building use and loading requirements, design errors, corrosion of reinforcement and construction mistakes during erection.
Researchers over the past two to three decades have been endeavoring to develop appropriate strengthening and repair techniques for RC columns that balances the structural requirement to enhance the strength, ductility and drift with various non-structural requirements, such as minimising implementation/construction costs, limiting any disruption to building occupants during construction, maintaining the aesthetics of the structure, maintaining or increasing durability and ensuring work safety. Time of repair is another crucial factor, particularly for post-disaster facilities, such as hospitals or emergency services facilities, and shelters that house a significant number of people. Similarly, the functionality of bridges also needs to be maintained or quickly restored immediately after an earthquake, which underscores the importance of rapid strengthening and repair techniques. There are also other challenges and complexities associated with strengthening and repair that need to be dealt with, such as localised changes to the member stiffness, which can possibly change the dynamic properties of the structure and, consequently, change the seismic demands on individual elements or the building as a whole
The earliest proposed strengthening techniques such as steel jacketing or concrete incasing enhanced the seismic performance of the structure by enlarging the cross-section of the column. Since then, researchers have been proposing and evaluating techniques that result in a minimum modification to the structural geometry, while simultaneously enhancing the structural capacity. Fiber-reinforced polymers (FRPs) have widely been seen as an attractive alternative to traditional retrofitting techniques and significant research efforts internationally have been undertaken to investigate various aspects of FRP strengthening. More recently, however, hybrid jacketing, which essentially combines the advantages of different retrofitting methods/materials, has become increasingly popular and the primary focus of most recent research efforts.
This paper provides a state-of-the-art review of different strengthening and repair techniques for RC columns over the last two decades. The authors have reviewed the effectiveness of each of the techniques and also identified potential future research areas to address research gaps.
It is noted that the term ‘repair’ in the context of this paper generally refers to any methods used to restore the capacity of a damaged RC column; whereas the terms ‘strengthening’ and ‘retrofitting’ are generally used interchangeably to refer to any methods used to enhance the capacity of existing RC column. The scope of the paper has generally been limited to ‘jacketing’ techniques for strengthening and/or repairing RC columns only. Other retrofitting techniques relating more directly to beam–column joints, such as the use of a haunch or knee brace [1,2], are outside the scope of this paper.
The strengthening and repair techniques for RC columns presented in this paper have been broadly categorized into six types, reinforced concrete/mortar jacketing; steel jacketing; externally bonded fiber-reinforced polymer jacketing; near-surface mounted fiber-reinforced polymer jacketing; shape memory alloy (SMA) jacketing; and hybrid jacketing. This state-of-the-art review included 99 studies that have been conducted on the strengthening of RC columns in the last two decades. Of these studies, externally bonded FRP strengthening has been the most popular method in literature, with approximately 59 studies, as shown in Figure 1.
Summaries of the experimental studies employing each of these six broad categories of strengthening and repair techniques is presented in Section 2, Section 3, Section 4, Section 5, Section 6 and Section 7 respectively. A summary of all the experimental studies for strengthening and repair techniques, respectively, is presented later in Table 1 and Table 2. The experimental studies were conducted under three types of loading conditions, namely, unidirectional cyclic lateral loading with constant axial load, bi-directional cyclic lateral loading with constant axial load and hybrid simulation. This is followed by Section 8, which provides a comparison and discussion of the different techniques, and Section 9, which presents research gaps and future potential research directions.

2. Reinforced Concrete/Mortar Jacketing

RC jacketing has been used extensively for strengthening and repairing deficient and damaged RC columns, respectively. In traditional reinforced concrete jacketing, the section of the column is enlarged by casting a new reinforced concrete/mortar section over a part or the entire length of the column. The new section is bonded to the original section through anchor rebars or high-strength bolts. Although this technique improves the seismic performance of the column in terms of axial load carrying capacity, flexural strength and ductility, it is costly and time consuming due to the installation of the formwork. Moreover, the improvement in ductility is relatively small because the jacketing material (i.e., concrete) is brittle. Furthermore, it results in a change in the cross-sectional area of the column, thereby changing the mass and stiffness of the structure, and hence reducing the natural period of the structure, which consequently results in higher seismic demands on the structure. Therefore, high-performance RC materials have been used more recently for jacketing purposes, so that the specimen is strengthened/repaired without a change in the cross-sectional size. The summary of the developments and improvements in the RC/mortar jacketing techniques is provided below.
Lehman et al. [3] repaired moderately to severely damaged circular RC columns with freshly cast concrete along with headed reinforcement and mechanical couplers and reported that although the strength and ductility were restored, the stiffness was not fully restored for moderately damaged columns. The repair technique also proved to be ineffective in restoring the behavior of severely damaged specimens.
Vandoros and Dristos [4] also used RC jackets with welded stirrup ends, which resulted in the enhancement of the strength and ductility of the RC columns; however, it was reported that the jacket separated from the original column due to a lack of surface/bonding treatment at the interface. The welding of stirrup ends proved to be effective in preventing the buckling of longitudinal reinforcement.
In another study, Chang et al. [5] compared the performance of RC jacketing and wing wall (small concrete panels installed at both sides of the column) installation and found that RC jacketing results in a larger enhancement of energy dissipation and ductility of the deficient RC columns.
In order to reduce the disruption of occupancy, Liu et al. [6] proposed the use of a single asymmetric concrete section for strengthening RC columns. The section was bonded to the original section with anchor rebars or high-strength bolts. The results exhibited a significant increase in the ultimate strength and ductility of the retrofitted specimen. It was also reported that this method reduces the initial stress difference between the original and the retrofitted part. Moreover, the usability of the structure is also not affected as most of the strengthening work can be done outdoors without relocating the furniture/other equipment. In a similar study, Ou and Troung [7] proposed the addition of flanges in the weak axis of the RC column for strengthening RC columns in the first weak story of the existing buildings. The rectangular column would consequently change to L- and T- shaped configurations as shown in Figure 2. The results of the study demonstrated a ductile failure mode and enhanced lateral strength of the retrofitted specimens compared to the original rectangular columns; however, the strength of the retrofitted specimens was lower than the monolithic specimens with L- and T-configurations primarily due to the discontinuity of the longitudinal reinforcement in the retrofitted specimens.
Recently, the durability of high-performance materials has led to the increased use of such materials for the strengthening and repair purposes of RC columns. Cho et al. [8] used high-performance fiber-reinforced cementitious composite (HPFRCC) mortar in the plastic hinge region of the column and found that strengthening with HPFRCC mortar not only reduces bending and shear cracks but also improves the overall force–displacement, energy dissipation and stiffness degradation behavior of the column. Similarly, Meda et al. [9] proposed the use of high-performance fiber-reinforced concrete (HPFRC) to repair corrosion-damaged RC columns and reported reasonable enhancement in the strength of the repaired column.
Dagenais et al. [10] reported that jacketing columns with deficient lap splices in RC bridges with self-compacting ultra-high performance fiber-reinforced concrete (UHPFRC) resulted in the elimination of bond failure and concrete damage in the plastic hinge regions.
Other high-performance materials such as engineered cementitious composites (ECCs) and ferro-cement jackets were also used to strengthen short RC columns [11]. ECC is a mortar based composite reinforced with fibers, whereas ferro-cement is essentially reinforced mortar applied over closely spaced rebars. It was reported that compared to ferro-cement jacketing, ECC-jacketed specimens exhibited enhanced ductility, energy dissipation and inelastic deformation; however, shear strengths were comparable. ECC-jacketed specimens also showed improved seismic performance even at high axial load ratios. Previously, Abdullah and Takiguchi [12] reported that with ferro-cement jackets, columns exhibited stable cyclic response and improved ductility; however, no improvement was observed in the flexural strength.
More recently, Rodrigues et al. [13] repaired severely damaged RC columns by replacing the damaged concrete in the plastic hinge region with high-strength micro-concrete and welding of ruptured longitudinal bars. The subsequent testing of the repaired columns under bi-directional lateral loading with constant axial compression showed that the repair technique fully restored the strength and ductility of the columns; however, the stiffness was still lower than in the original specimen.
Wrapping with textile-reinforced concrete, which comprises carbon and glass fiber bundles has been proposed very recently by Yao et al. [14] for the repair of corrosion-damaged RC columns. The repair resulted in improved seismic performance in terms of yield load, ultimate bearing capacity, ductility and accumulated energy dissipation; however, the degree of improvement was found to be a function of the initial corrosion ratio, i.e., the higher the initial corrosion ratio, the lower the improvement in behavior.

3. Steel Jacketing

In steel jacketing, the RC section is enlarged by welding or bolting it with a steel section [15], where the gap between the concrete and steel is filled with grout. The method is effective in enhancing the seismic performance of the column but is generally costly, labor intensive and involves antirust work. Moreover, just like RC jacketing, due to the change in the cross-sectional size of the section, this method also changes the stiffness of the structure.
In a study, Daudey and Filiatrault [16] retrofitted RC rectangular columns with the steel jacket and reported that the as-built column failed at lower (1~2) ductility ratios due to the bond slip of the dowel bars, whereas all the retrofitted specimens showed stable cyclic response up to the ductility ratio of 6. No effect of the geometry of the steel jacket, i.e., circular or elliptical, was observed on the performance of the strengthened columns. Wu et al. [17], in a separate study, reported that attaching a steel plate to the flexure faces of the RC column effectively delayed the concrete crushing in the plastic hinge zone.
Steel tube-jacketed square RC columns (STRC) and circular RC columns (CTRC) were tested by Zhou and Liu [18] to evaluate the effectiveness of strengthening RC columns with steel tubes nearly a decade ago. It was reported that tubed RC short columns performed better than conventional RC columns in terms of the displacement ductility, flexural strength, energy dissipation capacity and stable hysteretic behavior due to the effective confinement of concrete provided by the steel tube. For CTRC, it was reported that the brittle shear failure was effectively prevented and increasing the axial load ratio increased the lateral strength and decreased the ductility index; however, very little effect was observed on plastic deformation capacity. On the other hand, STRC was reported to exhibit shear failure at high axial load and an increase in axial load ratio increased the shear strength and decreased the ductility index and the deformation capacity. Overall, the lateral load strength of STRC was reported to be greater than that of CTRC, whereas the deformation capacity of the latter was higher.
Recently, Choi et al. [19] compared the seismic performance of circular RC columns with full and split prefabricated steel wrapping jackets and reported that split jacket results in nearly similar improvement in the seismic performance as that of a full jacket, and hence are more effective from the cost/ease of installation perspective. In this study, the external confining pressure on the steel wrapping jacket was exerted using a cable and a cross device as shown in Figure 3. Similarly, in a study by Pudjisuryadi et al. [20], the behavior of specimens with conventional stirrups was compared with the specimens provided with external steel angle collars at regular spacing over the height of the specimen. It was observed that specimens with steel angle collars showed very ductile behavior and failed at a higher drift compared to the specimens with stirrups for confinement purposes.
In order to minimize the modification to column geometry, mass and stiffness, Fakharifar et al. [21] proposed a rapid strengthening method comprising lightweight prestressed steel jackets for severely damaged RC columns. In this method, several prestressed strands restrain a thin steel sheet, which is then wrapped around the column in the form of a jacket in less than 12 h. The prestressed strands prevent buckling of the steel sheet, whereas steel sheet prevents strands from intruding into the cracked concrete. The results of the experimental study indicated that the strengthening method restored the ultimate strength and ductility of the retrofitted columns to 115 and 140%, respectively, of the original as-built columns. However, the initial stiffness was restored to 80% of the stiffness of the as-built columns.
More recently, Wang et al. [22] proposed an innovative strengthening method in which rectangular RC columns supporting high axial load ratios (i.e., preloaded) were strengthened with post compressed steel plates. The primary purpose of this method was to ensure that the column does not collapse in a severe earthquake and its axial load carrying capacity remains intact even after severe damage. It was reported that the existing axial and seismic shear loads were effectively sustained and shared by the precambered plates. A significant enhancement in the ductility and energy dissipation capacity of the strengthened column was also observed. Moreover, it was found that the improvement in behavior was more pronounced with the increase in the thickness of the steel plates rather than an increase in the precamber of the plates.

4. Externally Bonded Fiber-Reinforced Polymer (FRP) Jacketing

FRP jacketing is one of the most popular seismic retrofitting methods all over the world, primarily because of the many advantages FRP composites have to offer over traditional strengthening methods (RC and steel jacketing), such as ease and speed of installation, less labor work, minimum change to the original geometry and aesthetics of the structure, high strength-to-weight ratio, and, most importantly, its occupant-friendly nature. However, it has certain disadvantages as well, such as, the effective utilization of externally bonded FRP is just 30–35%, due to premature debonding [23]. Moreover, FRP is relatively costly and shows poor properties when exposed to high temperatures or wet environment. FRP is generally bonded externally to the column using epoxy resins. Different types of FRP composites have been utilized by different researchers for strengthening purposes, the details of which are provided below.

4.1. Carbon Fiber-Reinforced Polymer (CFRP) Composites

Among all the FRP composites, carbon fiber-reinforced polymers (CFRP) have been the most extensively used for strengthening and repairing RC columns in the last two decades. The majority of studies utilized externally bonded CFRP for strengthening RC columns. This section discusses in detail the various findings of the previous studies related to the general behavior of CFRP-strengthened and repaired columns. Moreover, the comparative effectiveness of CFRP wrapping with respect to other strengthening techniques is also presented. Due to a large number of studies on CFRP strengthening, the studies have been grouped into three categories, namely, CFRP strengthening, CFRP repair and comparative assessment of CFRP with other materials.

4.1.1. CFRP Strengthening

A large number of studies have been conducted to assess the impact of CFRP strengthening on the general behavior and failure modes of the strengthened RC columns. Ma et al. [24] reported that deficient RC columns retrofitted with external CFRP jacketing exhibited stable flexural response with improved ductility and energy dissipation capacity by preventing brittle shear failure. Similarly, Ye et al. [25] found that shear strength of the RC column with inadequate transverse reinforcement can be improved with the CFRP sheets. Moreover, the shear resistance mechanism of CFRP sheets was observed to be similar to reinforcement hoops where it became effective after the diagonal shear cracking of concrete. In another study, Ye et al. [26] reported that ductility of RC columns can be improved by CFRP sheet wrapping due to the confinement effect by CFRP when the strong shear and weak flexure factor is over 1.
Similarly, Sause et al. [27] noted that higher deformation capacity and delay in the column failure due to compression zone deterioration and longitudinal reinforcement buckling can be achieved by using FRP jackets with higher stiffness, i.e., greater thickness. The authors also reported that CFRP confinement in the plastic hinge zone significantly improved the deformation capacity, whereas lateral strength or stiffness did not increase significantly. Ghobarah and Galal [28] and Haroun and Elsanadedy [29] also reported that CFRP strengthening prevented the brittle shear failure and improved the ductility from limited to moderate. Another study by Haroun and Elsanadedy [75] concluded that square or rectangular jackets could not develop enough strength required to prevent the slippage or splitting of lap-spliced bars. Thus, circular or elliptical FRP jackets were assumed to be more effective.
While investigating the behavior of columns with lap splices, Harries et al. [30] found that with CFRP retrofitting, the nominal flexural capacity of the column can be achieved; however, after the occurrence of slip and splitting, CFRP jackets had no apparent effect on the residual splice capacity. The ductility of the columns was also reported to be limited by the slip of the lap-spliced bars and resulted in splitting failure in the spliced region. Harajli and Dagher [31] and Harajli [32] also observed that FRP wraps improved the bond strength of the spliced bar, increased the lateral load capacity and resistance and ductility of columns and reduced the bond deterioration and pinching of columns with lap splices.
A few studies were also conducted to study the influence of the geometry of column on the effectiveness of CFRP strengthening. In this regard, Abdel-Mooty et al. [33] reported that the influence of wrapping was more effective in square columns than rectangular columns. In a separate study, Ghosh and Sheikh [76] observed that FRP confinement was more prominent in circular columns as compared to the square ones. It was also stated that for previously damaged columns, the effectiveness of FRP improvement depends on the level of damage experienced.
While studying the behavior of the strengthened columns, Ozcan et al. [34] found that CFRP strengthening increased the rotation capacity of the non-ductile RC columns up to two times. Similarly, Harajli and Khalil [35] observed much more stable hysteretic behavior with increased energy dissipation capacity and reduced strength and stiffness degradation for FRP strengthened columns. The stresses in the FRP were reported to decrease with more layers. Moreover, it was also observed that improvement in bond strength with external FRP confinement is insensitive to the column section shape.
In a study related to the performance of continuous wraps with discontinuous ones, Colomb et al. [36] observed that for specimens fully wrapped with FRP along the length, failure mode was changed from brittle shear to ductile flexural while columns with discontinuous wraps observed mixed shear-flexure failure. Similarly, Yalcin et al. [37] found that with plain rebar dowels, an externally applied passive CFRP strengthening scheme is not effective unless plain rebars are sufficiently developed. ElGawady et al. [38], on the other hand, found that increasing the amount of FRP improves the performance of seismically deficient columns by limiting the budging of the jacket. In a separate study, Ozcan et al. [39] observed that FRP retrofitted columns sustained up to three times higher ultimate drift ratios as compared to unstrengthened deficient columns. It was also reported that using a 16-pinned CFRP anchor dowel configuration can increase the confinement efficiency and ultimate drift ratios.
Interestingly, Liu and Sheikh [41] found that lateral confinement by FRP increases energy dissipation and curvature ductility dramatically, but displacement ductility and drift capacity do not increase significantly beyond a certain limit. Moreover, it was also reported that lateral confinement by FRP at high axial load ratios leads to a remarkable increase in the flexural strength of the column, which is neglected by most design codes.
To address the debonding behavior of FRP wraps, Vrettos et al. [40] proposed an innovative method, which comprised CFRP sheets anchored to the column via carbon-fiber anchors as shown in Figure 4 and concluded that the use of carbon-fiber anchors is effective in the flexural strengthening of the columns if anchors have a significant amount of fibers. It was also reported that the effectiveness of anchors increases almost nearly with the increase in their weight.
In order to overcome the significant stress hysteresis problem of the FRP sheets relative to the concrete core, which essentially weakens the effectiveness of the strengthening method, Zhou et al. [77] used prestressed FRP strips with epoxy bonding. The FRP sheets were prestressed using a self-locking anchor, which was composed of anchors heads, nuts, screws and FRP strips. The results indicated the beneficial effects of prestressing FRP strips such as inhibiting the development of diagonal shear cracks and a change of mode of failure from brittle to ductile, consequently leading to an overall improvement in the seismic performance of the specimens in terms of energy dissipation, load capacity and ductility.
In a recent study by Paultre et al. [42], it was found that the enhancement in energy dissipation with CFRP strengthening is more pronounced for specimens with a relatively higher amount of transverse reinforcement and lower axial load ratio.
Juntanalikit et al. [43] reported that after CFRP jacketing, lap-splice deficient specimens do not experience gravity load collapse, as the core, which mainly bears the gravity load, is effectively confined against concrete crushing and spalling by the CFRP jackets.
Recently, Lee et al. [44] proposed an innovative technique in which FRPs, composed of an open-air mixture of chopped glass and carbon fibers with epoxy and vinyl ester resin, are sprayed on the uneven surface of the RC columns. The results indicated a significant improvement in the strength and deformation behavior of the strengthened specimens in comparison to the control specimen. The authors recommended the technique for the strengthening of low- to mid-rise RC buildings.
Wang et al. [45] have recently concluded that the axial load ratio and the number of CFRP wraps do not influence the degradation of effective and reloading stiffness of the columns much.
In another separate study, Zoppo et al. [46] investigated the effectiveness of CFRP strengthening in improving the seismic behavior of short RC columns with poor and medium quality concrete. The specimens characterised by low concrete strength were strengthened with low axial rigidity CFRP sheets, which resulted in an enhancement of the shear capacity but were not sufficient to avoid the brittle failure. It was reported that CFRP sheets with an axial rigidity of 0.34 GPa were able to produce ductile failure in the specimens with low-quality concrete. On the other hand, specimens with medium quality concrete were strengthened with CFRP sheets of relatively high axial rigidity and resulted in a ductile failure mode.
Castillo et al. [47], on the other hand, used FRP anchors and a bond breaking layer with FRP sheets in order to overcome the debonding disadvantage of the FRP sheets in strengthening RC columns. It was observed that due to the inclusion of a novel bond breaking layer, the premature debonding of FRP sheet was prevented and the ductility of the column was enhanced.
More recently, the effect of loading direction on the seismic performance of CFRP-retrofitted RC columns was investigated by Wang et al. [48]. It was found that with the increase in the angle of lateral loading from the strong axis, the energy dissipation and drift capacity of the column generally reduced. Moreover, although CFRP-retrofitted columns performed better than the corresponding unretrofitted columns, the improvement declined with the increase in lateral loading direction angle. Furthermore, worse seismic performance in terms of ultimate and plastic deformation capacity was noted when the loading angle was 60 degrees.
The comparative effectiveness of full CFRP wrapping with strap CFRP wrapping has also been assessed by different researchers. Yang and Wang [78] evaluated the seismic performance of shear controlled columns strengthened with CFRP straps and full CFRP sheet. It was observed that irrespective of the pre-damage condition of the columns, the CFRP wrapping enhanced the shear capacity and ductility of the deficient columns. However, the improvement in behavior reduced with the increasing axial load ratio. CFRP retrofitting also led to gradual post-peak strength degradation and a reduction in the pinching effect in hysteretic behavior. The authors concluded that at the same volumetric ratio, retrofitting with CFRP straps is a superior strategy compared to the wrapping of columns with full CFRP sheets. In a similar study, Wang et al. [49] studied the effectiveness of CFRP strap strengthening and full CFRP wrapping in improving the seismic performance of high-strength RC columns. However, in contrast to the previous study, it was found that full CFRP wrapping over the length of the column produces better results in terms of strength and ductility compared to wrapping in straps over the length. It was also reported that the strength and stiffness degradation, and pinching effect reduced with the increase in the number of CFRP layers.
It is generally believed that columns with extended cross-sections do not perform very well with CFRP strengthening. To investigate this issue, Ghatte et al. [50] conducted a study very recently, in which deficient RC columns with extended cross-sectional dimensions corresponding to the lateral loading direction (h/b = 2) were retrofitted with externally bonded CFRP Jackets, and an increase in the column drift capacity from 3 to 4% for specimens retrofitted with one layer of CFRP and from 3 to 7.5% for specimens retrofitted with two layers of CFRP at an axial load ratio of 0.2 was reported. On the other hand, the drift capacity at an axial load ratio of 0.35 increased from 1.5 to 3 and 5%, respectively, for specimens retrofitted with one and two layers of CFRP.

4.1.2. CFRP Repair

Some of the studies have also investigated the efficacy of CFRP wrapping in the repair of damaged RC columns. The type of damage included the corrosion of rebars, yielding of rebars, concrete spalling and severe damage until failure. Lee et al. [79] repaired RC columns damaged with different levels of rebar corrosion with CFRP sheets and observed that the confinement and shear strengthening by CFRP sheets prevented the growth of shear and bond-splitting cracks and improved the ductility of the repaired RC columns. The ductility and strength capacity of the corrosion-damaged CFRP-strengthened columns with inadequate lap-splice length was found to be higher than the original un-corroded column [80].
Kalyoncuoglu et al. [81] compared the effectiveness of repair with mortar and CFRP jacketing for corrosion-damaged RC columns made of substandard concrete and observed that in contrast to mortar rehabilitated column which considerably increased the strength, CFRP retrofitting improved both the strength as well as ductility of repaired columns.
Recently, Faustino and Chastre [82] tested five columns strengthened with CFRP combined with different strengthening mechanisms such as anchor dowels, external longitudinal bars and high-strength repair mortar. The columns were pre-damaged until yielding of longitudinal bars. The results of the experimental study showed an increase of 7% in the lateral load carrying capacity of the columns, when retrofitted with CFRP sheets only. However, CFRP sheets combined with high-strength mortar in the plastic hinge region resulted in an increase in the column lateral strength by 20%. Similarly, the use of CFRP sheets with external longitudinal steel also increased the lateral strength of the column by 20%.
To investigate the effect of multi-directional loading, Hashemi et al. [83] repaired a fully damaged RC column with CFRP wrapping and mortar and evaluated the effectiveness of the CFRP wrapping in restoring the strength and deformation capacity of the column via hybrid simulation, i.e., dynamic loading conditions in all the three directions (bi-directional loading with a variation of axial load). The results of the experimental testing exhibited a substantial enhancement in the ductility of the column; however, strength was not fully restored, primarily because damaged rebars were not repaired.
In the repair method by Parks et al. [84], the cross-section of the specimens was changed from original octagonal to a circular cross-section using epoxy-anchored headed bars and by filling a CFRP shell with concrete, thereby shifting the plastic hinge region to a less damaged region as shown in Figure 5. It was reported that the repair methodology successfully restored the force–displacement capacity of the damaged columns.
More recently, the results of the experimental study with bi-directional lateral loading conducted by Rodrigues et al. [85] demonstrated that the energy dissipation capacity of the severely damaged specimens was restored after CFRP jacketing. It was also reported that the viscous damping of the repaired specimens was higher than the original specimens.

4.1.3. Comparative Assessment of CFRP Effectiveness with Other Materials

Some researchers have compared the relative improvement in the column’s behavior after strengthening with CFRP with that of other retrofitting materials. In this regard, Harajli and Rteil [51] compared the effectiveness of CFRP and steel FRC strengthening for RC columns with lap splices. It was reported that the external CFRP confinement significantly improved the seismic performance of columns by decreasing the spliced bars’ bond deterioration and improving the energy dissipation capacity of the columns. Similar improvements were reported for internally confined columns with steel FRC.
In another study, Bousias et al. [86] repaired RC columns with or without corrosion-damaged reinforcement with CFRP or GFRP wrapping. The effectiveness of FRP wrapping (G or C) was reported to be the same if the extensional stiffness was kept similar in the circumferential direction. Moreover, the effectiveness of FRP strengthening was found to be more beneficial in the column’s strong direction (smaller face) as compared to the weak direction. It was also reported that the effectiveness of FRP wraps as strengthening material is reduced in RC columns with corroded bars because they become the weak link instead of the confined compression zone. Interestingly, in a separate study by Galal et al. [52], CFRP was found to be more effective than GFRP in strengthening the short square RC columns as it increased the shear force and energy dissipation capacity while decreased the FRP and steel tie strains along the column height.
Similarly, Bousias et al. [53] compared the efficacy of RC and CFRP jacketing on RC columns with lap splices and reported that FRP jacketing in the hinge zones and splice regions was found to be more effective than the RC jacketing.
On the other hand, Bournas et al. [54] evaluated the effectiveness of CFRP and textile-reinforced mortar (TRM) strengthening and found that the performance of TRM was equally effective as CFRP of equal stiffness.
Thermou and Pantazopoulou [87] reported an interesting finding that the axial stiffness of the jacket rather than the strength was the defining factor in determining the performance of FRP retrofitting, as both GFRP and CFRP with equal axial stiffness had equivalent effects on the strength and deformation capacity improvements.
More recently, a comparative analysis of the effectiveness of carbon fiber-reinforced polymer (CFRP) wrapping and fiber-reinforced cementitious composite (FRCC) in improving the seismic performance of RC columns with poor and medium quality concrete was conducted by Zoppo et al. [55]. The results of the experimental study showed that CFRP wrapping is more effective in strengthening columns with poor quality concrete. However, the authors concluded that FRCC jacketing can also serve as a reasonable alternative to CFRP jacketing as it not only reduced the concrete deterioration, but also prevented bar buckling and enhanced lateral strength and energy dissipation of the specimens.

4.2. Glass Fiber-Reinforced Polymer (GFRP)

Over the last two decades, few studies have used glass fiber-reinforced polymer for strengthening purposes and reported its benefits. Sheikh and Yau [88] repaired pre-damaged columns having yielded longitudinal bars with GFRP wrapping and reported that the energy dissipation capacity of strengthened columns increased by over a hundred times. Similarly, Memon and Sheikh [89] evaluated the efficacy of GFRP wraps in strengthening deficient or damaged square RC columns. It was found that the strengthening technique enhanced the ductility, energy dissipation and strength capacity of the deficient and damaged columns; however, the extent of enhancement was a function of the existing damage of the column. A reduction in the rate of stiffness and strength degradation with the increase in the number of GFRP layers was also observed. Moreover, for columns supporting high axial loads, a greater number of GFRP layers was needed to produce a similar improvement in the behavior as that of the columns with low axial load ratios. Youm et al. [56] also reported that GFRP retrofitting significantly improved the seismic performance of lap-spliced columns by stabilising the hysteresis response and increasing the displacement ductility factor to 8.3 as compared to un-retrofitted columns of 2.6, which failed prematurely due to lap splice bond failure. It was observed that regardless of GFRP layer thickness, which delayed bond slip failure to a great extent, the yielding of spliced bars was not achieved. In a similar study, Eshghi and Zanjanizadeh [57] also observed that GFRP retrofit was effective in improving the splice bond strength, flexural strength, and displacement ductility and rotation capacity of as-built columns which failed in a brittle manner due to bond deterioration of spliced rebars. It was also argued that GFRP retrofitting can present a practical solution to avoid the soft-storey mechanism in RC structures with deficient detailing.
Recently, Choi et al. [58] reported the effectiveness of strengthening with tensioned GFRP winding wires in improving the seismic performance of RC columns with and without lap splices. The study consisted of two columns with lap splices and two with continuous longitudinal reinforcement. One column of each of the two categories was strengthened with tensioned GFRP wires as shown in Figure 6. The results of the experimental testing showed that GFRP wire winding increased the flexural strength and failure drift of the strengthened columns of both categories compared with the control specimens. Moreover, it was observed that GFRP wire winding prevents buckling of the longitudinal reinforcement, vertical splitting of the lap splices and concrete spalling. Seo et al. [90] also proposed another quick and easy-to-install method comprising a GFRP strip device which is composed of a strip of GFRP composite with a aluminium clip connector and proposed to attach it in the plastic hinge region of the column. The experimental results showed a significant improvement in the seismic performance of the strengthened columns in terms of strength, displacement ductility and energy dissipation capacity. Moreover, the failure mode of the column was changed from a brittle shear to a ductile flexural mode.

4.3. Basalt Fiber-Reinforced Polymer (BFRP)

Due to its low price as compared to CFRP and other excellent properties such as resistance to fire and chemical corrosion, basalt fiber-reinforced polymer is recently being used for strengthening purposes. In this regard, Ouyang et al. [59] performed a comparative assessment of the effectiveness of externally bonded CFRP and BFRP wrapping and reported that columns strengthened with BFRP sheets exhibited equivalent and even superior performance to their counter parts with the same number of CFRP sheets. Moreover, the price of BFRP sheets was just 20% of the CFRP. In view of this, the authors recommended strengthening with BFRP as a viable alternative.

4.4. Polyester Fiber-Reinforced Polymer (PFRP)

Polyester fiber-reinforced polymer is known for its toughness, flexibility, heat resistance and durability, and hence has been used for strengthening purposes. In a study, Chang et al. [60] utilized polyester fiber-reinforced polymer for strengthening deficient RC columns. The sheet was bonded to the column using urethane adhesive. The study comprised one control specimen and two strengthened specimens with one and two layers of polyester belts, respectively. It was reported that the control specimen exhibited brittle behavior, whereas strengthened specimens experienced ductile behavior. Moreover, a significant improvement in the overall force–displacement behavior of the column was observed after strengthening. Furthermore, the energy dissipation of the polyester fiber-reinforced polymer strengthened specimen was 184% of that of the control specimen.

4.5. Polyethylene Terephthalate (PET) Fiber-Reinforced Polymer Composites

The polyethylene terephthalate FRP composites are made from recyclable materials and have the advantages of high deformability and economy over CFRP composites. Moreover, they possess greater tensile capacity than conventional FRPs. The study by Dai et al. [61] presented the results of PET FRP jacketed specimens and compared the results with a high-strength aramid FRP jacketed specimen. The results of the experimental study demonstrated that PET FRP is a viable alternative to conventional FRPs as it enhances the displacement ductility of RC columns significantly and also does not rupture at the ultimate limit state. More recently, Liu and Li [91] strengthened partially corroded RC columns with CFRP and polyethylene terephthalate (PET) FRP composites, respectively, as shown in Figure 7 and performed a comparative assessment of the relative performance of the two strengthening systems. The results of the experimental study evaluated in terms of energy dissipation, damping ratio, hysteretic performance and stiffness degradation indicated that strengthening using CFRP and PET FRP composites resulted in a nearly similar improvement in the seismic performance of the RC columns.

4.6. Hybrid Fiber-Reinforced Polymer (HFRP)

Researchers have been proposing new hybrid FRP composites, which are composed of two different fiber materials. In this way, the resulting hybrid material has the advantages of both individual materials. To study the effectiveness of HFRP strengthening, Peng et al. [92] repaired damaged (up to yielding of rebars) RC columns using sprayed BFRP and sprayed HFRP, which was composed of a mix of BFRP and CFRP. The results of the experiments demonstrated that the proposed strengthening method with HFRP enhances the energy dissipation and ductility of the pre-damaged columns considerably. However, no obvious increase in the peak loads was observed. The authors noted the advantages of this method as low cost and rapid strengthening due to the fast curing of materials. Similarly, Li and Li [93] proposed HFRP wrapping for enhancing the seismic performance of corroded RC columns. A total of six specimens including two control and four strengthened specimens were tested under constant axial load and cyclic lateral loading. The specimens were corroded using accelerated corrosion in the laboratory conditions and the HFRP sheets were wrapped in the plastic hinge region of the column. It was observed that the strengthening technique resulted in 47 and 212% enhancement in the displacement ductility and energy dissipation capacity of the strengthened specimens compared to the unstrengthened control specimens.

5. Near-Surface Mounted (NSM) Fiber-Reinforced Polymer (FRP) Jacketing

In the NSM method, grooves are cut into the cover concrete, and FRP bars are placed in the grooves and bonded using an appropriate filler, such as epoxy paste or cement grout. NSM FRP bars are usually used in the longitudinal direction to enhance the flexural strength of the column. Mostly, the NSM method is used in conjuction with externally bonded FRP jacketing, resulting in a hybrid jacketing as described in Section 7.
In order to investigate the difference between NSM rebar repair and CFRP wrapping, Hasan et al. [94] compared the repair effectiveness of three partially cracked stub RC columns with NSM rebar repair and CFRP laminate strengthening. It was reported that specimens with NSM rebars exhibited higher load capacity and better energy dissipation and ductility. On the other hand, specimens with CFRP wrapping demonstrated better crack formation and propagation behavior. The authors attributed the difference in the behavior of the two repairing techniques to the fact that NSM rebars contribute to the compression and tension behavior of the specimens, whereas CFRP laminates contribute in the tension zone only.

6. Shape Memory Alloy (SMA) Wire Jacketing

Shape memory alloys, that are characterized by their super elasticity, durability and shape memory effect have been considered for the strengthening of structural elements by different researchers. Moreover, SMA alloys are considered a more viable solution to FRP retrofitting due to the advantages such as no need for adhesive, easy installation and no danger of peel off. To investigate this, Choi et al. [62] employed two kinds of shape memory alloy wire jackets, nickel–titanium–niobium and nickel–titanium alloys, for the seismic retrofitting of RC columns. The jackets were attached to the concrete via anchors. The results of the experimental study showed that retrofitting with SMA alloys results in ductile behavior of the columns with lap splices. Moreover, it was observed that the performance of SMA-strengthened columns with lap splices was even better than columns without lap splices. It was reported that nickel–titanium–niobium alloys are more suited for retrofitting civil structures because they offer more appropriate temperature windows compared to nickel–titanium alloys.

7. Hybrid Jacketing

Hybrid jacketing involves a combination of two or more different strengthening methods/materials for enhancing the seismic performance of a column and, thus, benefits from the advantages of both methods. This section summarizes the experimental studies utilizing the hybrid jacketing approach for the strengthening and repair of RC columns.

7.1. NSM Bars with FRP Wrapping

In this hybrid jacketing technique, FRP sheets are used in conjunction with NSM bars, where FRP sheets provide lateral confinement and NSM bars enhance the flexural strength of the column, thereby resulting in enhancement of both the strength and ductility. Wu et al. [63] used this technique by embedding GFRP bars in the plastic hinge zone in addition to the provision of CFRP wraps. It was reported that the retrofitting method effectively delayed the concrete failure and prevented the buckling of longitudinal reinforcement. As a result, the ductility and energy dissipation capacity of retrofitted columns were increased. Similar findings were reported by Bournas and Triantafillou [64] for strengthened columns with different types and configurations of NSM reinforcing materials (steel or FRP). Confinement was also provided by the local jacketing of textile-reinforced mortar (TRM) by FRP sheets. Based on the test results, it was reported that NSM FRP or stainless steel present a feasible solution for the flexural strengthening of RC columns under seismic loading and with proper design and local jacketing at column ends, strength enhancement does not adversely affect the deformation capacity. Local jacketing was reported to be very effective in controlling the buckling of NSM reinforcements, which resulted in the higher strain at failure. In another study, Sarafraz and Danesh [65] also strengthened RC columns with NSM FRP rebars inserted in the grooves cut into the concrete surface combined with CFRP wrapping over the height of the column. It was reported that NSM rebars increase the flexural capacity of the column significantly. Moreover, lateral strength and energy dissipation capacity increase with the increase in the number of NSM rebars. Furthermore, it was observed that the combination of NSM bars with CFRP wrapping improves the overall seismic performance of the column remarkably.
In another study, Li et al. [66] proposed using NSM GFRP rebars and CFRP jackets and CFRP anchors in the potential plastic hinge region for strengthening RC columns with a large side aspect ratio. Four types of strengthening layouts were used. In the first layout, the specimen was strengthened with CFRP jackets and CFRP anchors, whereas in the second layout NSM GFRP rebars were also provided in addition to CFRP jackets and CFRP anchors. The third layout had CFRP jackets and NSM GFRP bars, while the last layout had NSM GFRP rebars only. The results of the tests indicated that strengthening by NSM GFRP rebars enhances the flexural strength of the strengthened specimens, whereas CFRP jackets and CFRP anchors increase both the strength and ductility of the column.
Recently, in the study by Napoli and Realfonzo [67], longitudinal rebars were embedded in the grooves cut into the concrete and continuous CFRP wrapping was done in the plastic hinge region of the column, whereas discontinuous CFRP strips were provided in the remaining length of the column. Moreover, in the second layout, steel angles were also used in addition to the longitudinal bars and CFRP sheets. The results of the experimental study exhibited an increase of 48 and 60% in the flexural strength for layout 1 and 2, respectively, compared to the control specimen. It was also noticed that the presence of steel angles delayed the collapse of the specimen with the second layout such that the specimen was able to undergo greater displacement excursions.
Researchers have been using different types of FRP composites in hybrid jacketing techniques. Seyhan et al. [68] proposed the strengthening of deficient RC columns with embedded aramid fiber-reinforced polymer (AFRP) reinforcement in the longitudinal direction to increase the flexural strength and CFRP sheets in the transverse direction to enhance the ductility under cyclic lateral actions with constant axial compression. The proposed retrofitting method resulted in the significant enhancement of the flexural strength of the tested columns. Moreover, the specimens failed at a reasonably satisfactory drift of 3.0%. It was also found that the column provided with fully bonded anchorage performed better than the one with partially bonded anchorage. Similarly, Fahmy and Wu [69] utilized NSM basalt fiber-reinforced polymer (BFRP) bars in grooves and a BFRP jacket in the plastic hinge region to retrofit RC columns with lap-splice deficiencies. It was found that the BFRP bar’s texture is the most important parameter that affects the seismic performance of the strengthened columns. Rebars with a rough texture helped eliminate residual displacements and resulted in a gradual increase in the column strength after yielding as compared to smooth rebars. Moreover, the drift capacity of the specimen strengthened with rough BFRP rebars was in the order of 4.5%, compared with columns strengthened with smooth rebars where the drift capacity was up to 3.0%. Similarly, Jiang et al. [95] proposed a repair method comprising NSM BFRP rebars and BFRP sheets jacketing for earthquake damaged RC bridge columns as shown in Figure 8. It was reported that the proposed retrofitting method successfully restored the stiffness and flexural and displacement capacity of the column to a level such that the bridge structure could be used for emergency services after an earthquake.
More recently, Seifi et al. [70] strengthened deficient RC columns representative of older construction practices (pre 1970s) with near-surface mounted glass fiber-reinforced polymer (GFRP) composites and NSM steel rebars. After placing the NSM reinforcement bars in the grooves on the column surface, the specimens were wrapped with CFRP. Both strengthening techniques (GFRP bars and steel bars) resulted in a significant improvement in the flexural strength, energy dissipation and hysteretic damping of the columns. However, the improvement in the behavior of the specimens with NSM steel bars was more pronounced.

7.2. Self-Compacting Concrete-Filled CFRP-Steel Tubes (CFCSTs)

In this hybrid jacketing technique, a concrete-filled steel tube and CFRP wrapping are used for strengthening RC columns. This was proposed by Lu et al. [71] quite recently. In this technique, the gap between the RC column and steel tube is filled by self-compacting concrete and layers of CFRP wraps are also provided around the steel tubes. The test results demonstrated an increase of 7.4–9.7 times and 42–116% in the ultimate lateral load carrying capacity and ductility of the column, respectively. An increase in the thickness of the steel tubes resulted in better overall seismic performance (both ductility and ultimate bearing capacity). The presence of CFRP wraps around steel tubes delayed the buckling of steel tubes in CFCSTs, and hence improved the seismic performance significantly.

7.3. FRP Sheets with Steel Jacketing

Li et al. [96] evaluated the effectiveness of combined CFRP and steel jackets in improving the seismic performance of corrosion-damaged RC columns. It was reported that the repair of damaged columns with combined CFRP and steel was more effective in improving the strength and ductility than strengthening with the individual material. Also, in damaged columns with higher levels of reinforcement corrosion, the improvements of strengthening were more prominent than those with a lower degree of corrosion. A higher axial load was reported to considerably reduce the ductility of the strengthened columns; however, the strengthening effect was higher than those with lower axial load. Similarly, Realfonzo and Napoli [72] performed tests on some columns strengthened by steel angles and FRP wraps. It was reported that providing the steel angles anchored to foundation on the column corners improved the flexural strength as compared to the use of FRP only.
A study by ElSouri and Harajli [97] compared the seismic performance of lap-spliced RC columns on strengthening with internal steel ties, external fiber-reinforced polymer sheets and a combination of both. It was found that the repair/strengthening of the columns with internal ties, external FRP sheets or a combination of both improved the seismic performance significantly in terms of lateral load, energy dissipation and drift capacity. Moreover repaired/strengthened columns experienced much less damage than the as-built unstrengthened columns.
Recently, Chou et al. [73] proposed an innovative hybrid jacketing method in which a GFRP-wrapped corrugated steel tube, as shown in Figure 9, was used to improve the seismic performance of RC columns. The presence of a corrugated tube allowed for the creation of a ribbed surface between the concrete and FRP. The results of the experimental study showed a significant increase in the drift capacity of the columns with the increase in the number of GFRP layers. Moreover, the failure mode changed from shear to flexure with the increase in GFRP wraps. Furthermore, the proposed strengthening technique also resulted in increased energy dissipation and the high shear strength of the specimens.
More recently, Afshin et al. [102] proposed a novel hybrid jacketing technique comprising CFRP sheets on the outer periphery and a steel profile on the inside of corrosion-damaged RC bridge columns. The results of the experimental testing showed that the proposed retrofitting method improved the energy absorption and strength degradation behavior of the repaired specimens; however, there was not much improvement in the displacement ductility behavior of the columns.

7.4. High-Performance Materials with Steel/FRP Rebars or FRP Wrapping

The use of high-performance materials together with steel/FRP rebars or FRP wrapping is also an attractive hybrid repair method. Ma and Li [98] reported the improvement in the seismic performance of moderately to severely damaged RC columns, which were strengthened with fast curing early-strength cement mortar and basalt fiber-reinforced polymer sheets as shown in Figure 10. Significant improvement in the energy dissipation capacity and ductility of the specimens was noticed after strengthening with early-strength cement mortar and basalt fiber-reinforced polymer sheets. Moreover, the flexural capacity of the specimens with moderate pre-damage was fully restored. However, the flexural capacity of severely pre-damaged specimens was only partially restored. Also, the initial stiffness of the strengthened specimens was not fully restored and decreased with the increase in the pre-damage level of high-performance fiber-reinforced cementitious composite (HPFRCC)-sprayed mortar with steel bars to improve the seismic performance of old RC columns.
Another such method comprising turned steel rebars and high-performance fibre reinforced concrete (HPFRC) with steel or polymer fibres was proposed by Xue et al. [99] for repairing severely damaged circular RC bridge columns. In this technique, transverse rebars were first cut and then the damaged longitudinal rebars of the column were removed and replaced with new shaped (turned) rebar segments. This was followed by the construction of a concrete jacket consisting of HPFRC with steel or polymer fibres. The strengthening technique successfully restored the ductility, strength and stiffness of the column and further enhanced the energy dissipation capacity. However, the increase in energy dissipation capacity was less for the HPFRC with polymer fibres as opposed to the column with the steel fibres.
Recently, Cho et al. [74] proposed the use of high-performance fibre-reinforced cementitious composite (HPFRCC) sprayed mortar with steel bars to improve the seismic performance of old RC columns. In the retrofitting method, the surface of the column was grooved first, and then longitudinal and transverse rebars were placed in the groove. Finally, the section of column was enhanced by spraying HPFRC mortar. The results of the cyclic lateral loading tests conducted on the retrofitted columns demonstrated the effectiveness of the technique in improving both the load carrying and deformation capacities of the strengthened columns. The strengthening technique also reduced the bending and diagonal shear cracks in the retrofitted columns in contrast to the un-retrofitted specimens. A significant improvement in the hysteretic damping energy of the strengthened column was also observed.
More recently, high performance fiber-reinforced concrete (HPFRC) was used in conjunction with FRP wrapping by Rajput et al. [100] to repair corrosion-damaged RC columns. The columns were strengthened with HPFRC and one or two layers of glass fiber-reinforced polymers (GFRP). It was reported that with the combination of HPFRC and GFRP, the retrofitted columns met the strength requirements of the code for seismically designed column; however, the ductility improvement was reported to be inadequate.

7.5. Thin Cold-Formed Steel Sheet with Prestressing Strands

Prestressing strands with a thin cold-formed steel sheet can be used in rapid and light-weight repair of the earthquake-damaged bridge piers. Fakharifar et al. [101] proposed this hybrid jacketing technique, which involved wrapping the damaged RC column with a thin cold-formed steel sheet on the inside and prestressing strands on the outside, as shown in Figure 11. Moreover, repair grout was used to replace the damaged concrete. The repair method was applied on one large-scale substandard RC column representative of pre-1970s construction practice. The original column was first damaged until 25% strength degradation under constant axial load and cyclic lateral actions and was then repaired using the proposed retrofitting technique. The results of the experimental study demonstrated that the hybrid confinement technique is very effective in enhancing the flexural strength and ductility of the damaged column.

8. Comparison and Discussion of Different Techniques

Numerous different strengthening and repair techniques for RC columns have been presented in the previous sections that included over 90 different experimental studies, including over 500 column specimens. The various techniques have been broadly categorized into six different categories, RC jacketing; steel jacketing; externally bonded FRP jacketing; near-surface mounted FRP or steel reinforcement; shape memory alloy (SMA) wire jacketing; and hybrid jacketing, as discussed in the previous sections. A summary of the benefits and drawbacks for each category of techniques has been summarized in Table 3.
The six broad retrofitting and strengthening categories have been compared using six generic criteria, as follows: effect on strength; effect on ductility; effective on stiffness; cost of strengthening; aesthetics; and impact to occupants, which specifically, is the impact to the building occupants while the strengthening and repairing techniques are being undertaken. This last category would generally be of less concern to infrastructure (i.e., RC bridge columns). A matrix summarizing the performance of each technique for each category is presented in Table 4. It should be noted that the performance levels in Table 4 are broad characterizations only, which have generally been developed from the results and observations of the individual studies presented in the previous section. The actual performance/effectiveness of each strengthening or retrofitting technique will vary on a case-by-case basis and be dependent on the individual circumstances at the time.
Each of the retrofitting and strengthening techniques was generally able to increase the strength of the column. However, the steel jacketing, near-surface mounted FRP/steel reinforcement and hybrid jacketing methods resulted in the largest strength increase. Similarly, each technique was capable of generally increasing the amount of ductility. However, the steel, externally bonded FRP and hybrid jacketing were typically more effective and resulted in higher levels of ductility. However, it is noted that debonding limits the effective confinement of externally bonded FRP columns. A comparative analysis of different material stress-strain models for FRP-confined concrete and their influence on the ultimate behavior of FRP-confined RC columns is presented in Montuori et al. [103,104].
The stiffness generally remained unchanged, except for the RC and steel jacketing, which often increased the stiffness (due to the fact that the overall column cross-section was typically increased), and the SMA wire jacketing, where the stiffness was decreased. Changing the stiffness of the column was generally considered a poor outcome, since that would affect the dynamic properties of the structure. However, it is noted in some situations that changing the dynamic properties of the structure can be a positive outcome.
The RC jacketing and steel jacketing generally involve lower cost construction materials with a simple and direct load transmission mechanism [105]. However, they are typically very labor intensive and time consuming. As such, they were considered the most ineffective from a cost perspective. While the cost of materials for externally bonded FRP and near-surface mounted FRP is considerably higher than the former two techniques, the cost of the transportation of materials and installation is much cheaper, which allows for the overall technique to be typically more cost effective. The externally bonded FRP and near-surface mounted FRP/steel reinforcement were also considered to be the best technique from an aesthetics/impact to floorplan perspective, since they result in the least/smallest changes to the column cross section. In contrast, the RC jacketing technique typically increases the column dimensions significantly and, hence, is considered to have the biggest impact on aesthetics and the overall floorplan of a building.
The impact to the occupants category was generally based on two criteria: the first was how long the technique would take to be installed/constructed; and the second was in relation to the construction activities that would need to be performed. RC jacketing and hybrid jacketing typically require a considerable amount for cutting or drilling into the existing concrete, which causes a significant impact due to noise, duration and dust or general construction debris, therefore giving them a lower ranking, whereas, externally bonded FRP jacketing, which is typically quite quick to install and does not require any loud/dirty drilling and cutting of the existing concrete, has therefore been assigned a high ranking.

9. Research Gaps and Future Research Directions

A review of the experimental studies conducted to investigate the effectiveness of different seismic strengthening and repair techniques indicates that the primary focus of the research in the past was on the repair of normal-strength ( f c 50   MPa ) RC columns. Figure 12a shows that in the past two decades, approximately 523 normal-strength RC columns with different strengthening techniques have been tested under simulated earthquake loading, whereas, in comparison, the seismic behavior of only 22 strengthened high-strength RC columns has been investigated so far. On the other hand, the dynamic characterization of concrete performed by Khosravani and Weinberg [106] showed that high-strength and ultra-high strength concrete are more brittle than normal-strength concrete and, therefore, RC columns with high-strength concrete collapse at a lesser drift than the latter [107,108,109,110]. Hence, it is expected that the efficiency of the strengthening and repair methods would reduce with the increase in the concrete compressive strength. In future research, this aspect needs to be studied with reference to different strengthening and repair techniques, as high-strength RC columns are being widely used in high-rise constructions all over the world, and such columns may need to be repaired after being damaged in a rare or very rare earthquake event.
Another important aspect that requires attention is the type of lateral loading path. A vast majority of the experimental studies involving strengthening and repair have been carried out under uni-directional cyclic lateral loading, and only a handful of tests have been conducted under bi-directional loading. It is shown in Figure 12b that in the last two decades, only 12 specimens were tested under bi-directional loading as opposed to 533 specimens tested under uni-directional loading. Recent experimental research conducted by the authors [108] has shown that the collapse drift capacity of the column reduces by approximately 50% under bi-directional loading scenarios. In view of this, it is essential to evaluate the comparative effectiveness of different retrofitting techniques under realistic multi-directional loading protocols.

10. Concluding Remarks

This paper presented a detailed overview of various strengthening and repair methods for reinforced concrete columns. These techniques can contribute to the sustainability of existing reinforced concrete infrastructure by ensuring the enhancement of their existing capacity without the need for rebuilding or replacement. Each technique is discussed extensively noting the advantages and disadvantages. The review of the findings of different researchers leads to the conclusion that although the strength, ductility and drift capacity of the damaged columns can be recovered and even enhanced by repair, it is very difficult to fully restore the initial stiffness of the damaged column.
Further, based on the review of the different strengthening and repair techniques, the authors are of the view that hybrid jacketing techniques, which combine the benefits of different materials/strengthening methods can often be the most effective since they have a relatively fast installation, can significantly improve the strength, ductility and drift and can maintain the aesthetics and original geometry/configuration of the structure.
This review also highlights potential research gaps for future research such as the investigation of the effectiveness of the strengthening and repair methods for high-strength RC columns, and also the evaluation of the efficacy of these techniques under realistic bi-directional loading protocols, as most of the studies are currently focussed on the seismic performance of strengthened columns under uni-directional lateral loading scenarios. Whilst older studies focussed on ductility levels that could be used in force based design procedures, contemporary testing has a much greater emphasis on drift behaviour of retrofitted columns that can be directly used in displacement based design methods.

Author Contributions

Writing, review and editing by S.R., M.K.I.K., S.J.M. and H.-H.T.; Supervision by H.-H.T. and J.L.W.

Funding

This research was funded by the Bushfire and Natural Hazards Cooperative Research Centre (BNHCRC), Melbourne, Australia.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Zabihi, A.; Tsang, H.H.; Gad, E.F.; Wilson, J.L. Seismic retrofit of exterior RC beam-column joint using diagonal haunch. Eng. Struct. 2018, 174, 753–767. [Google Scholar] [CrossRef]
  2. Tsang, H.-H. Innovative upscaling of architectural elements for strengthening building structures. Sustainability 2019, 11, 2636. [Google Scholar] [CrossRef]
  3. Lehman, D.E.; Gookin, S.E.; Nacamuli, A.M.; Moehle, J.P. Repair of earthquake-damaged bridge columns. Aci Struct. J. 2001, 98, 233–242. [Google Scholar]
  4. Vandoros, K.G.; Dritsos, S.E. Concrete jacket construction detail effectiveness when strengthening RC columns. Constr. Build. Mater. 2008, 22, 264–276. [Google Scholar] [CrossRef]
  5. Chang, S.Y.; Chen, T.W.; Tran, N.C.; Liao, W.I. Seismic retroftting of RC columns with RC jackets and wing walls with different structural details. Earthq. Eng. Eng. Vib. 2014, 13, 279–292. [Google Scholar] [CrossRef]
  6. Liu, C.Y.; Ma, H.; Chen, L.; Li, Z.B.; Yang, D.B. Experimental study on seismic performance of reinforced concrete column retrofitted by asymmetric increased single lateral section. Adv. Struct. Eng. 2017, 20, 1325–1339. [Google Scholar] [CrossRef]
  7. Ou, Y.C.; Truong, A.N. Cyclic behavior of reinforced concrete L-and T-columns retrofitted from rectangular columns. Eng. Struct. 2018, 177, 147–159. [Google Scholar] [CrossRef]
  8. Cho, C.G.; Kim, Y.Y.; Feo, L.; Hui, D.V. Cyclic responses of reinforced concrete composite columns strengthened in the plastic hinge region by HPFRC mortar. Compos. Struct. 2012, 94, 2246–2253. [Google Scholar] [CrossRef]
  9. Meda, A.; Mostosi, S.; Rinaldi, Z.; Riva, P. Corroded RC columns repair and strengthening with high performance fibre reinforced concrete jacket. Mater. Struct. 2016, 49, 1967–1978. [Google Scholar] [CrossRef]
  10. Dagenais, M.A.; Massicotte, B.; Boucher-Proulx, G. Seismic Retrofitting of Rectangular Bridge Piers with Deficient Lap Splices Using Ultrahigh-Performance Fibre-Reinforced Concrete. J. Bridge Eng. 2018, 23. [Google Scholar] [CrossRef]
  11. Deng, M.K.; Zhang, Y.X.; Li, Q.Q. Shear strengthening of RC short columns with ECC jacket: Cyclic behavior tests. Eng. Struct. 2018, 160, 535–545. [Google Scholar] [CrossRef]
  12. Abdullah; Takiguchi, K. An investigation into the behavior and strength of reinforced concrete columns strengthened with ferrocement jackets. Cem. Concr. Compos. 2003, 25, 233–242. [Google Scholar] [CrossRef]
  13. Rodrigues, H.; Furtado, A.; Arede, A.; Vila-Pouca, N.; Varum, H. Experimental study of repaired RC columns subjected to uniaxial and biaxial horizontal loading and variable axial load with longitudinal reinforcement welded steel bars solutions. Eng. Struct. 2018, 155, 371–386. [Google Scholar] [CrossRef]
  14. Li, Y.; Yin, S.-P.; Chen, W.-J. Seismic behavior of corrosion-damaged RC columns strengthened with TRC under a chloride environment. Constr. Build. Mater. 2019, 201, 736–745. [Google Scholar]
  15. Liu, X.; Lu, Z.-D.; Li, L.-Z. The use of bolted side plates for shear strengthening of RC beams: A review. Sustainability 2019, 10, 4658. [Google Scholar] [CrossRef]
  16. Daudey, X.; Filiatrault, A. Seismic evaluation and retrofit with steel jackets of reinforced concrete bridge piers detailed with lap-splices. Can. J. Civil Eng. 2000, 27, 1–16. [Google Scholar] [CrossRef]
  17. Wu, Y.F.; Griffith, M.C.; Oehlers, D.J. Improving the strength and ductility of rectangular reinforced concrete columns through composite partial interaction: Tests. J. Struct. Eng. 2003, 129, 1183–1190. [Google Scholar] [CrossRef]
  18. Zhou, X.H.; Liu, J.P. Seismic behavior and shear strength of tubed RC short columns. J. Constr. Steel Res. 2010, 66, 385–397. [Google Scholar] [CrossRef]
  19. Choi, E.; Chung, Y.S.; Park, C.; Kim, D.J. Seismic performance of circular RC columns retrofitted with prefabricated steel wrapping jackets. Mag. Concr. Res. 2013, 65, 1429–1440. [Google Scholar] [CrossRef]
  20. Pudjisuryadi, P.; Tavio; Suprobo, P. Performance of square reinforced concrete columns externally confined by steel angle collars under combined axial and lateral Load. Procedia Eng. 2015, 125, 1043–1049. [Google Scholar] [CrossRef]
  21. Fakharifarh, M.; Chen, G.D.; Wu, C.L.; Shamsabadi, A.; ElGawady, M.A.; Dalvand, A. Rapid repair of earthquake-damaged RC columns with prestressed steel jackets. J. Bridge Eng. 2016, 21. [Google Scholar] [CrossRef]
  22. Wang, L.; Su, R.K.L.; Cheng, B.; Li, L.Z.; Wan, L.; Shan, Z.W. Seismic behavior of preloaded rectangular RC columns strengthened with precambered steel plates under high axial load ratios. Eng. Struct. 2017, 152, 683–697. [Google Scholar] [CrossRef]
  23. Kotynia, R.; Baky, H.A.; Neale, K.W.; Ebead, U.A. Flexural strengthening of RC beams with externally bonded CFRP systems: Test results and 3D nonlinear FE analysis. J. Compos. Constr. 2008, 12, 190–201. [Google Scholar] [CrossRef]
  24. Ma, R.; Xiao, Y.; Li, K.N. Full-scale testing of a parking structure column retrofitted with carbon fibre reinforced composites. Constr. Build. Mater. 2000, 14, 63–71. [Google Scholar] [CrossRef]
  25. Ye, L.P.; Yue, Q.R.; Zhao, S.H.; Li, Q.W. Shear strength of reinforced concrete columns strengthened with carbon-fibre-reinforced plastic sheet. J. Struct. Eng. 2002, 128, 1527–1534. [Google Scholar] [CrossRef]
  26. Ye, L.P.; Zhang, K.; Zhao, S.H.; Feng, P. Experimental study on seismic strengthening of RC columns with wrapped CFRP sheets. Constr. Build. Mater. 2003, 17, 499–506. [Google Scholar] [CrossRef]
  27. Sause, R.; Harries, K.A.; Walkup, S.L.; Pessiki, S.; Ricles, J.M. Flexural behavior of concrete columns retrofitted with carbon fibre-reinforced polymer jackets. Aci Struct. J. 2004, 101, 708–716. [Google Scholar]
  28. Ghobarah, A.; Galal, K.E. Seismic rehabilitation of short rectangular RC columns. J. Earthq. Eng. 2004, 8, 45–68. [Google Scholar] [CrossRef]
  29. Haroun, M.A.; Elsanadedy, H.M. Behavior of Cyclically Loaded Squat Reinforced Concrete Bridge Columns Upgraded with Advanced Composite-Material Jackets. J. Bridge Eng. 2005, 10, 749–757. [Google Scholar] [CrossRef]
  30. Harries, K.A.; Ricles, J.M.; Pessiki, S.; Sause, R. Seismic retrofit of lap splices in nonductile square columns using carbon fibre-reinforced jackets. Aci Struct. J. 2006, 103, 874–884. [Google Scholar]
  31. Harajli, M.H.; Dagher, F. Seismic strengthening of bond-critical regions in rectangular reinforced concrete columns using fibre-reinforced polymer wraps. Aci Struct. J. 2008, 105, 68–77. [Google Scholar]
  32. Harajli, M.H. Seismic behavior of RC columns with bond-critical regions: Criteria for bond strengthening using external FRP jackets. J. Compos. Constr. 2008, 12, 69–79. [Google Scholar] [CrossRef]
  33. Abdel-Mooty, M.A.N.; Issa, M.E.; Farag, H.M.; Bitar, M.A. Seismic Upgrading of Square and Rectangular RC Columns using FRP Wrapping. In High Performance Structures and Materials III; Brebbia, C.A., Ed.; Wessex Institute of Technology: Ashurst, UK, 2006. [Google Scholar]
  34. Ozcan, O.; Binici, B.; Ozcebe, G. Improving seismic performance of deficient reinforced concrete columns using carbon fibre-reinforced polymers. Eng. Struct. 2008, 30, 1632–1646. [Google Scholar] [CrossRef]
  35. Harajli, M.H.; Khalil, Z. Seismic FRP retrofit of bond-Critical regions in circular RC columns: Validation of proposed design methods. Aci Struct. J. 2008, 105, 760–769. [Google Scholar]
  36. Colomb, F.; Tobbi, H.; Ferrier, E.; Hamelin, P. Seismic retrofit of reinforced concrete short columns by CFRP materials. Compos. Struct. 2008, 82, 475–487. [Google Scholar] [CrossRef]
  37. Yalcin, C.; Kaya, O.; Sinangil, M. Seismic retrofitting of R/C columns having plain rebars using CFRP sheets for improved strength and ductility. Constr. Build. Mater. 2008, 22, 295–307. [Google Scholar] [CrossRef]
  38. ElGawady, M.; Endeshaw, M.; McLean, D.; Sack, R. Retrofitting of rectangular columns with deficient lap splices. J. Compos. Constr. 2010, 14, 22–35. [Google Scholar] [CrossRef]
  39. Ozcan, O.; Binici, B.; Ozcebe, G. Seismic strengthening of rectangular reinforced concrete columns using fibre reinforced polymers. Eng. Struct. 2010, 32, 964–973. [Google Scholar] [CrossRef]
  40. Vrettos, I.; Kefala, E.; Triantafillou, T.C. Innovative flexural strengthening of reinforced concrete columns using carbon-fibre anchors. Aci Struct. J. 2013, 110, 63–70. [Google Scholar]
  41. Liu, J.; Sheikh, S.A. Fibre-reinforced polymer-confined circular columns under simulated seismic loads. Aci Struct. J. 2013, 110, 941–951. [Google Scholar]
  42. Paultre, P.; Boucher-Trudeau, M.; Eid, R.; Roy, N. Behavior of circular reinforced-concrete columns confined with carbon fibre-reinforced polymers under cyclic flexure and constant axial load. J. Compos. Constr. 2016, 20. [Google Scholar] [CrossRef]
  43. Juntanalikit, P.; Jirawattanasomkul, T.; Pimanmas, A. Experimental and numerical study of strengthening non-ductile RC columns with and without lap splice by Carbon Fibre Reinforced Polymer (CFRP) jacketing. Eng. Struct. 2016, 125, 400–418. [Google Scholar] [CrossRef]
  44. Lee, K.S.; Lee, B.Y.; Seo, S.Y. A seismic strengthening technique for reinforced concrete columns using sprayed FRP. Polymers (Basel) 2016, 8, 107. [Google Scholar] [CrossRef] [PubMed]
  45. Wang, D.Y.; Huang, L.; Yu, T.; Wang, Z.Y. Seismic performance of CFRP-retrofitted large-scale square RC columns with high axial compression ratios. J. Compos. Constr. 2017, 21. [Google Scholar] [CrossRef]
  46. Del Zoppo, M.; Di Ludovico, M.; Balsamo, A.; Prota, A.; Manfredi, G. FRP for seismic strengthening of shear controlled RC columns: Experience from earthquakes and experimental analysis. Compos. Part B Eng. 2017, 129, 47–57. [Google Scholar] [CrossRef]
  47. Castillo, E.D.; Griffith, M.; Ingham, J. Seismic behavior of RC columns flexurally strengthened with FRP sheets and FRP anchors. Compos. Struct. 2018, 203, 382–395. [Google Scholar] [CrossRef]
  48. Wang, D.Y.; Wang, Z.Y.; Yu, T.; Li, H. Seismic performance of CFRP-retrofitted large-scale rectangular RC columns under lateral loading in different direction. Compos. Struct. 2018, 192, 475–488. [Google Scholar] [CrossRef]
  49. Wang, J.Z.; Yang, J.L.; Cheng, L. Experimental study of seismic behavior of high-strength RC columns strengthened with CFRP subjected to cyclic loading. J. Struct. Eng. 2019, 145. [Google Scholar] [CrossRef]
  50. Ghatte, H.F.; Comert, M.; Demir, C.; Akbaba, M.; Ilki, A. Seismic retrofit of full-scale substandard extended rectangular RC columns through CFRP jacketing: Test results and design recommendations. J. Compos. Constr. 2019, 23. [Google Scholar] [CrossRef]
  51. Harajli, M.H.; Rteil, A.A. Effect of confinement using fibre-reinforced polymer or fibre-reinforced concrete on seismic performance of gravity load-designed columns. Aci Struct. J. 2004, 101, 47–56. [Google Scholar]
  52. Galal, K.; Arafa, A.; Ghobarah, A. Retrofit of RC square short columns. Eng. Struct. 2005, 27, 801–813. [Google Scholar] [CrossRef]
  53. Bousias, S.; Spathis, A.L.; Fardis, M.N. Seismic retrofitting of columns with lap spliced smooth bars through FRP or concrete jackets. J. Earthq. Eng. 2007, 11, 653–674. [Google Scholar] [CrossRef]
  54. Bournas, D.A.; Lontou, P.; Papanicolaou, C.G.; Triantafillou, T.C. Textile-reinforced mortar versus fibre-reinforced polymer confinement in reinforced concrete columns. Aci Struct. J. 2007, 104, 740–748. [Google Scholar]
  55. Del Zoppo, M.; Di Ludovico, M.; Balsamo, A.; Prota, A. Comparative analysis of existing RC columns jacketed with CFRP or FRCC. Polymers (Basel) 2018, 10, 361. [Google Scholar] [CrossRef] [PubMed]
  56. Youm, K.S.; Lee, Y.H.; Choi, Y.M.; Hwang, Y.K.; Kwon, T.G. Seismic performance of lap-spliced columns with glass FRP. Mag. Concr. Res. 2007, 59, 189–198. [Google Scholar] [CrossRef]
  57. Eshghi, S.; Zanjanizadeh, V. Retrofit of slender square reinforced concrete columns with glass fibre-reinforced polymer for seismic resistance. Iran. J. Sci. Technol. B 2008, 32, 437–450. [Google Scholar]
  58. Choi, E.; Cho, B.S.; Lee, S. Seismic retrofit of circular RC columns through using tensioned GFRP wires winding. Compos. Part B Eng. 2015, 83, 216–225. [Google Scholar] [CrossRef]
  59. Ouyang, L.J.; Gao, W.Y.; Zhen, B.; Lu, Z.D. Seismic retrofit of square reinforced concrete columns using basalt and carbon fibre-reinforced polymer sheets: A comparative study. Compos. Struct. 2017, 162, 294–307. [Google Scholar] [CrossRef]
  60. Chang, C.; Kim, S.J.; Park, D.; Choi, S. Experimental investigation of reinforced concrete columns retrofitted with polyester sheet. Earthq. Struct. 2014, 6, 237–250. [Google Scholar] [CrossRef]
  61. Dai, J.G.; Lam, L.; Ueda, T. Seismic retrofit of square RC columns with polyethylene terephthalate (PET) fibre reinforced polymer composites. Constr. Build. Mater. 2012, 27, 206–217. [Google Scholar] [CrossRef]
  62. Choi, E.; Chung, Y.S.; Choi, D.H.; DesRoches, R. Seismic protection of lap-spliced RC columns using SMA wire jackets. Mag. Concr. Res. 2012, 64, 239–252. [Google Scholar] [CrossRef]
  63. Wu, Y.F.; Liu, T.; Wang, L.M. Experimental investigation on seismic retrofitting of square RC columns by carbon FRP sheet confinement combined with transverse short glass FRP bars in bored holes. J. Compos. Constr. 2008, 12, 53–60. [Google Scholar] [CrossRef]
  64. Bournas, D.A.; Triantafillou, T.C. Flexural strengthening of reinforced concrete columns with near-surface-mounted FRP or stainless steel. Aci Struct. J. 2009, 106, 495–505. [Google Scholar]
  65. Sarafraz, M.E.; Danesh, F. New technique for flexural strengthening of RC columns with NSM FRP bars. Mag. Concr. Res. 2012, 64, 151–161. [Google Scholar] [CrossRef]
  66. Li, X.; Lv, H.L.; Zhang, G.C.; Sha, S.Y.; Zhou, S.C. Seismic retrofitting of rectangular reinforced concrete columns using fibre composites for enhanced flexural strength. J. Reinf. Plast. Comp. 2013, 32, 619–630. [Google Scholar] [CrossRef]
  67. Napoli, A.; Realfonzo, R. RC columns strengthened with novel CFRP systems: An experimental study. Polymers (Basel) 2015, 7, 2044–2060. [Google Scholar] [CrossRef]
  68. Seyhan, E.C.; Goksu, C.; Uzunhasanoglu, A.; Ilki, A. Seismic behavior of substandard RC columns retrofitted with embedded aramid fibre reinforced polymer (AFRP) reinforcement. Polymers (Basel) 2015, 7, 2535–2557. [Google Scholar] [CrossRef]
  69. Fahmy, M.F.M.; Wu, Z.S. Exploratory study of seismic response of deficient lap-splice columns retrofitted with near surface-mounted basalt FRP bars. J. Struct. Eng. 2016, 142. [Google Scholar] [CrossRef]
  70. Seifi, A.; Hosseini, A.; Marefat, M.S.; Khanmohammadi, M. Seismic retrofitting of old-type RC columns with different lap splices by NSM GFRP and steel bars. Struct. Des. Tall. Spec. 2018, 27. [Google Scholar] [CrossRef]
  71. Lu, Y.Y.; Yi, S.; Liang, H.J.; Gong, T.N.; Li, N. Seismic behavior of RC square columns strengthened with self-compacting concrete-filled CFRP-steel tubes. J. Bridge Eng. 2019, 24. [Google Scholar] [CrossRef]
  72. Realfonzo, R.; Napoli, A. Cyclic behavior of RC columns strengthened by FRP and steel devices. J. Struct. Eng. 2009, 135, 1164–1176. [Google Scholar] [CrossRef]
  73. Chou, C.C.; Lee, C.S.; Wu, K.Y.; Chin, V.L. Development and validation of a FRP-wrapped spiral corrugated tube for seismic performance of circular concrete columns. Constr. Build. Mater. 2018, 170, 498–511. [Google Scholar] [CrossRef]
  74. Cho, C.G.; Han, B.C.; Lim, S.C.; Morii, N.; Kim, J.W. Strengthening of reinforced concrete columns by High-Performance Fibre-Reinforced Cementitious Composite (HPFRC) sprayed mortar with strengthening bars. Compos. Struct. 2018, 202, 1078–1086. [Google Scholar] [CrossRef]
  75. Haroun, M.A.; Elsanadedy, H.M. Fibre-reinforced plastic jackets for ductility enhancement of reinforced concrete bridge columns with poor lap-splice detailing. J. Bridge Eng. 2005, 10, 749–757. [Google Scholar] [CrossRef]
  76. Ghosh, K.K.; Sheikh, S.A. Seismic upgrade with carbon fibre-reinforced polymer of columns containing lap-spliced reinforcing bars. Aci Struct. J. 2007, 104, 227–236. [Google Scholar]
  77. Zhou, C.D.; Lu, X.L.; Li, H.; Tian, T. Experimental study on seismic behavior of circular RC columns strengthened with pre-stressed FRP strips. Earthq. Eng. Eng. Vib. 2013, 12, 625–642. [Google Scholar] [CrossRef]
  78. Yang, J.L.; Wang, J.Z. Seismic performance of shear-controlled CFRP-strengthened high-strength concrete square columns under simulated seismic load. J. Compos. Constr. 2018, 22. [Google Scholar] [CrossRef]
  79. Lee, H.S.; Kage, T.; Noguchi, T.; Tomosawa, F. An experimental study on the retrofitting effects of reinforced concrete columns damaged by rebar corrosion strengthened with carbon fibre sheets. Cem. Concr. Res. 2003, 33, 563–570. [Google Scholar] [CrossRef]
  80. Aquino, W.; Hawkins, N.M. Seismic retrofitting of corroded reinforced concrete columns using carbon composites. Aci Struct. J. 2007, 104, 348–356. [Google Scholar]
  81. Kalyoncuoglu, A.; Ghaffari, P.; Goksu, C.; Ilki, A. Rehabilitation of corrosion-damaged substandard RC columns using FRP sheets. Adv. Mater. Res. 2013, 639–640, 1096–1103. [Google Scholar] [CrossRef]
  82. Faustino, P.; Chastre, C. Damage effect on concrete columns confined with carbon composites. Aci Struct. J. 2016, 113, 951–962. [Google Scholar] [CrossRef]
  83. Hashemi, M.J.; Al-Ogaidi, Y.; Al-Mahaidi, R.; Kalfat, R.; Tsang, H.H.; Wilson, J.L. Application of hybrid simulation for collapse assessment of post-earthquake CFRP-repaired RC columns. J. Struct. Eng. 2017, 143. [Google Scholar] [CrossRef]
  84. Parks, J.E.; Brown, D.N.; Ameli, M.J.; Pantelides, C.P. Seismic repair of severely damaged precast reinforced concrete bridge columns connected with grouted splice sleeves. Aci Struct. J. 2016, 113, 615–626. [Google Scholar] [CrossRef]
  85. Rodrigues, H.; Furtado, A.; Arede, A. Experimental evaluation of energy dissipation and viscous damping of repaired and strengthened RC columns with CFRP jacketing under biaxial load. Eng. Struct. 2017, 145, 162–175. [Google Scholar] [CrossRef]
  86. Bousias, S.N.; Triantafillou, T.C.; Fardis, M.N.; Spathis, L.; O’Regan, B.A. Fibre-reinforced polymer retrofitting of rectangular reinforced concrete columns with or without corrosion. Aci Struct. J. 2004, 101, 512–520. [Google Scholar]
  87. Thermou, G.E.; Pantazopoulou, S.J. Fibre-reinforced polymer retrofitting of pre-damaged substandard RC prismatic members. J. Compos. Constr. 2009, 13, 535–546. [Google Scholar] [CrossRef]
  88. Sheikh, S.A.; Yau, G. Seismic behavior of concrete columns confined with steel and fibre-reinforced polymers. Aci Struct. J. 2002, 99, 72–80. [Google Scholar]
  89. Memon, M.S.; Sheikh, S.A. Seismic resistance of square concrete columns retrofitted with glass fibre-reinforced polymer. Aci Struct. J. 2005, 102, 774–783. [Google Scholar]
  90. Seo, H.; Kim, J.; Kwon, M. Evaluation of damaged RC columns with GFRP-strip device. J. Compos. Constr. 2016, 20. [Google Scholar] [CrossRef]
  91. Liu, X.F.; Li, Y. Experimental study of seismic behavior of partially corrosion-damaged reinforced concrete columns strengthened with FRP composites with large deformability. Constr. Build. Mater. 2018, 191, 1071–1081. [Google Scholar] [CrossRef]
  92. Peng, Y.J.; Gu, Q.; Gao, R.; Bitewlgn, G. Experimental research on seismic behavior of seismically damaged RC frame column strengthened with sprayed hybrid BF/CFRP. Appl. Mech. Mater. 2014, 501–504, 1592–1599. [Google Scholar] [CrossRef]
  93. Li, J.H.; Li, Y. Experimental and theoretical study on the seismic performance of corroded RC circular columns strengthened with hybrid fibre reinforced polymers. Polym. Polym. Compos. 2014, 22, 653–659. [Google Scholar]
  94. Hasan, Q.F.; Tekeli, H.; Demir, F. NSM Rebar and CFRP laminate strengthening for RC columns subjected to cyclic loading. Constr. Build. Mater. 2016, 119, 21–30. [Google Scholar] [CrossRef]
  95. Jiang, S.F.; Zeng, X.G.; Shen, S.; Xu, X.C. Experimental studies on the seismic behavior of earthquake-damaged circular bridge columns repaired by using combination of near-surface-mounted BFRP bars with external BFRP sheets jacketing. Eng. Struct. 2016, 106, 317–331. [Google Scholar] [CrossRef]
  96. Li, J.B.; Gong, J.X.; Wang, L.C. Seismic behavior of corrosion-damaged reinforced concrete columns strengthened using combined carbon fibre-reinforced polymer and steel jacket. Constr. Build. Mater. 2009, 23, 2653–2663. [Google Scholar] [CrossRef]
  97. ElSouri, A.M.; Harajli, M.H. Seismic repair and strengthening of lap splices in RC columns: Carbon fibre-reinforced polymer versus steel confinement. J. Compos. Constr. 2011, 15, 721–731. [Google Scholar] [CrossRef]
  98. Ma, G.; Li, H. Experimental study of the seismic behavior of pre-damaged reinforced-concrete columns retrofitted with basalt fibre-reinforced polymer. J. Compos Constr. 2015, 19. [Google Scholar] [CrossRef]
  99. Xue, J.; Lavorato, D.; Bergami, A.V.; Nuti, C.; Briseghella, B.; Marano, G.C.; Ji, T.; Vanzi, I.; Tarantino, A.M.; Santini, S. Severely damaged reinforced concrete circular columns repaired by turned steel rebar and high-performance concrete jacketing with steel or polymer fibres. Appl. Sci. 2018, 8, 1671. [Google Scholar] [CrossRef]
  100. Rajput, A.S.; Sharma, U.K.; Engineer, K. Seismic retrofitting of corroded RC columns using advanced composite materials. Eng. Struct. 2019, 181, 35–46. [Google Scholar] [CrossRef]
  101. Fakharifar, M.; Chen, G.D.; Arezoumandi, M.; Eigawady, M. Hybrid jacketing for rapid repair of seismically damaged reinforced concrete column. Transp. Res. Rec. 2015, 2522, 70–78. [Google Scholar] [CrossRef]
  102. Afshin, H.; Shirazi, M.R.N.; Abedi, K. Experimental and numerical study about seismic retrofitting of corrosion-damaged reinforced concrete columns of bridge using combination of FRP wrapping and steel profiles. Steel Compos. Struct. 2019, 30, 231–251. [Google Scholar]
  103. Montuori, R.; Piluso, V.; Tisi, A. Comparative analysis and critical issues of the main constitutive laws for concrete elements confined with FRP. Compos. Part B Eng. 2012, 43, 3219–3230. [Google Scholar] [CrossRef]
  104. Montuori, R.; Piluso, V.; Tisi, A. Ultimate behaviour of FRP wrapped sections under axial force and bending: Influence of stress–strain confinement model. Compos. Part B Eng. 2013, 54, 85–96. [Google Scholar] [CrossRef]
  105. Ramírez, J. Ten concrete column repair methods. Constr. Build. Mater. 1996, 10, 195–202. [Google Scholar] [CrossRef]
  106. Khosravani, M.R.; Weinberg, K. A review on split Hopkinson bar experiments on the dynamic characterisation of concrete. Constr. Build. Mater. 2018, 190, 1264–1283. [Google Scholar] [CrossRef]
  107. Raza, S.; Tsang, H.H.; Menegon, S.J.; Wilson, J.L. Seismic Performance Assessment of Reinforced Concrete Columns in Regions of Low to Moderate Seismicity. In Resilient Structures and Infrastructure; Noroozinejad Farsangi, E., Takewaki, I., Yang, T., Astaneh-Asl, A., Gardoni, P., Eds.; Springer: Berlin/Heidelberg, Germany, 2019. [Google Scholar]
  108. Raza, S.; Menegon, S.J.; Tsang, H.-H.; Wilson, J.L. Collapse performance of limited ductile high-strength RC columns under uni-directional cyclic actions. J. Struct. Eng. 2019. Under Review. [Google Scholar]
  109. Raza, S.; Tsang, H.-H.; Wilson, J.L. Unified models for post-peak failure drifts of normal- and high-strength RC columns. Mag. Concr. Res. 2018, 70, 1081–1101. [Google Scholar] [CrossRef]
  110. Raza, S.; Menegon, S.J.; Tsang, H.H.; Wilson, J.L. Experimental Assessment of High-Strength RC Columns Under Different Bi-Directional Loading Protocols. In Proceedings of the 2019 Pacific Conference on Earthquake Engineering, SkyCity, Auckland, New Zealand, 4–6 April 2019. [Google Scholar]
Figure 1. An overview of the experimental studies on the strengthening and repair of reinforced concrete (RC) columns published in the last two decades.
Figure 1. An overview of the experimental studies on the strengthening and repair of reinforced concrete (RC) columns published in the last two decades.
Sustainability 11 03208 g001
Figure 2. Repair with RC Jacketing: (a) Removing the cover concrete and roughening the surface; (b) Post-installation of transverse reinforcement; (c) Welding of transverse reinforcement; Reinforcement cage for an (d) L-shaped column; (e) T-shaped column; (f) T-shaped column with wall-type reinforcement [7-Elsevier Copyrights].
Figure 2. Repair with RC Jacketing: (a) Removing the cover concrete and roughening the surface; (b) Post-installation of transverse reinforcement; (c) Welding of transverse reinforcement; Reinforcement cage for an (d) L-shaped column; (e) T-shaped column; (f) T-shaped column with wall-type reinforcement [7-Elsevier Copyrights].
Sustainability 11 03208 g002
Figure 3. Jacketing with prefabricated steel sheets: (a) Cutting to shape of steel plates; (b,c) Installation of steel plates and exertion of external pressure using cable and a cross device; (d) Welding to complete the jacketing process [19-ICE Publishing Copyrights].
Figure 3. Jacketing with prefabricated steel sheets: (a) Cutting to shape of steel plates; (b,c) Installation of steel plates and exertion of external pressure using cable and a cross device; (d) Welding to complete the jacketing process [19-ICE Publishing Copyrights].
Sustainability 11 03208 g003
Figure 4. (a) Filling holes in the anchorage region with epoxy resin; (b) Placement of carbon-fiber anchor; (c) Fanning out of fiber anchors over a CFRP sheet; (d) Local jacketing with CFRP [40-Authorized Reprint from American Concrete Institute].
Figure 4. (a) Filling holes in the anchorage region with epoxy resin; (b) Placement of carbon-fiber anchor; (c) Fanning out of fiber anchors over a CFRP sheet; (d) Local jacketing with CFRP [40-Authorized Reprint from American Concrete Institute].
Sustainability 11 03208 g004
Figure 5. Repair procedure with CFRP shell and concrete: (a) Post-installed headed bars; (b) Split CFRP shell; (c) CFRP shell around column; (d) CFRP shell filled with non-shrink or expansive concrete [84-Authorized Reprint from American Concrete Institute].
Figure 5. Repair procedure with CFRP shell and concrete: (a) Post-installed headed bars; (b) Split CFRP shell; (c) CFRP shell around column; (d) CFRP shell filled with non-shrink or expansive concrete [84-Authorized Reprint from American Concrete Institute].
Sustainability 11 03208 g005
Figure 6. GFRP wire jacketing: (a) Winding of the GFRP wire; (b) completed GFRP winding [58-Elsevier Copyrights].
Figure 6. GFRP wire jacketing: (a) Winding of the GFRP wire; (b) completed GFRP winding [58-Elsevier Copyrights].
Sustainability 11 03208 g006
Figure 7. (a) Corrosion damaged; (b) CFRP repaired; (c) PET FRP repaired [91-Elsevier Copyrights].
Figure 7. (a) Corrosion damaged; (b) CFRP repaired; (c) PET FRP repaired [91-Elsevier Copyrights].
Sustainability 11 03208 g007
Figure 8. Hybrid repair procedure with NSM rebars and FRP wrapping: (a) Column after straightening; (b) Column after loose concrete removal and chiseling grooves; (c) Clearing the holes and grooves; (d) Injecting epoxy adhesive and placing the NSM BFRP rebars; (e) Repair mortar placement; (f) BFPR sheet application. [95-Elsevier Copyrights].
Figure 8. Hybrid repair procedure with NSM rebars and FRP wrapping: (a) Column after straightening; (b) Column after loose concrete removal and chiseling grooves; (c) Clearing the holes and grooves; (d) Injecting epoxy adhesive and placing the NSM BFRP rebars; (e) Repair mortar placement; (f) BFPR sheet application. [95-Elsevier Copyrights].
Sustainability 11 03208 g008
Figure 9. FRP-wrapped spiral corrugated tube configuration [73-Elsevier Copyrights].
Figure 9. FRP-wrapped spiral corrugated tube configuration [73-Elsevier Copyrights].
Sustainability 11 03208 g009
Figure 10. Hybrid repair process using high performance materials and FRP wrapping: (a) Early-strength cement mortar pouring; (b) Epoxy injection; (c) BFRP wrapping [98-With Permission from ASCE].
Figure 10. Hybrid repair process using high performance materials and FRP wrapping: (a) Early-strength cement mortar pouring; (b) Epoxy injection; (c) BFRP wrapping [98-With Permission from ASCE].
Sustainability 11 03208 g010
Figure 11. Repair procedure with the hybrid confining jacket: (a) Damaged column; (b) Patched column with repair grout; (c) Sheet metal wrapping; (d) Prestressing strands application [101-SAGE Copyrights].
Figure 11. Repair procedure with the hybrid confining jacket: (a) Damaged column; (b) Patched column with repair grout; (c) Sheet metal wrapping; (d) Prestressing strands application [101-SAGE Copyrights].
Sustainability 11 03208 g011
Figure 12. Overview of the experimental tests on strengthened and repaired RC columns: (a) Normal-strength vs. high-strength concrete; (b) Uni-directional vs. bi-directional lateral loading.
Figure 12. Overview of the experimental tests on strengthened and repaired RC columns: (a) Normal-strength vs. high-strength concrete; (b) Uni-directional vs. bi-directional lateral loading.
Sustainability 11 03208 g012
Table 1. Summary of studies on the strengthening of RC columns.
Table 1. Summary of studies on the strengthening of RC columns.
StudyStrengthening MethodStrength and DuctilityInitial Stiffness
RC/Mortar Jacketing
Vandoros and Dristos [4]Concrete jacketing with end-welded stirrups and dowel placement. Shotcrete jacket with bent-down barsEnhancedEnhanced
Chang et al. [5]RC jacketing and wing wall installation.EnhancedEnhanced
Liu et al. [6]Addition of a single asymmetric concrete section using anchor rebars or high-strength boltsEnhancedEnhanced
Ou and Truong [7]Addition of a RC flange in the weak axis of the columnEnhancedEnhanced
Cho et al. [8]High-performance fiber-reinforced cementitious composite (HPFRCC) mortarEnhancedNot reported
Dagenais et al. [10]Self-compacting ultra-high performance fiber-reinforced concreteEnhancedSame
Deng et al. [11]Comparison of engineered cementitious composites (ECCs) and ferro-cement jacketSame strength for both but more ductility with ECCsEnhanced
Abdullah and Takiguchi [12]Circular or square ferro-cement jackets with steel wire meshImproved ductility but no flexural strength improvementSimilar
Steel Jacketing
Daudey and Filiatrault [16]Steel tube jacketing with concrete or grout fillEnhancedNot reported
Wu et al. [17]Steel plate to flexural facesEnhancedEnhanced
Zhou and Liu [18]Jacketing with steel tubeEnhancedNot reported
Choi et al. [19]Wrapping with steel jacketStrength the same, ductility enhancedLower
Pudjisuryadi et al. [20]Jacketing with steel angle collarsEnhancedNot reported
Wang et al. [22]Jacketing with post-compressed steel platesEnhancedEnhanced
Externally-bonded Fiber-reinforced polymer (FRP) Jacketing
Ma et al. [24]Carbon fiber-reinforced polymer (CFRP) wrapping in plastic hinge regionEnhancedNot reported
Ye et al. [25]Discontinuous CFRP wrapping in stripsEnhancedNot reported
Sause et al. [27]CFRP jacket confinement in inelastic hinge regionInsignificant increase in strength and considerable increase in ductilityInsignificant increase
Ghobarah and Galal [28]CFRP wrapping with fiber anchorsSlight enhancement in strength, whereas significant enhancement in ductilityNot reported
Haroun and Elsanadedy [29]CFRP and E-Glass wrappingEnhancedSame
Harries et al. [30]CFRP wrapping in the plastic hinge regionEnhancedNot reported
Harajli and Dagher [31]FRP wrapping in the plastic hinge zoneEnhancedNot reported
Harajli [32]FRP jacketing in spliced zoneEnhancedNot reported
Abdel-Mooty et al. [33]Glass or carbon FRP wrapping in potential hinge zoneEnhancedNot reported
Ozcan et al. [34]CFRP retrofittingNegligible increase in strength but ductility significantly enhancedNot reported
Harajli and Khalil [35]FRP Jacketing in spliced zoneEnhancedNot reported
Colomb et al. [36]Glass or carbon FRP wrapsEnhancedNot reported
Yalcin et al. [37]CFRP wrapping in the plastic hinge regionMore enhancement for specimens without lap splice as opposed to the ones with lap spliceSlightly increased
ElGawady et al. [38]CFRP retrofitting and Steel jacketingEnhancedSame
Ozcan et al. [39]CFRP wrapping with CFRP anchor dowelsEnhancement in ductility onlyNot reported
Vrettos et al. [40]CFRP wrapping in plastic hinge regions with and without CFRP anchorsEnhancedEnhanced with the use of CFRP anchors
Liu and Sheikh [41]FRP wrappingEnhancedNot reported
Paultre et al. [42]Full CFRP wrappingMore enhancement in ductility than strengthNot reported
Juntanalikit et al. [43]CFRP wrapping in the plastic hinge regionEnhancedNot reported
Lee et al. [44]Sprayed FRP composed of a mixture of chopped glass and carbon fibersEnhancedNot reported
Wang et al. [45]CFRP wrapping in the plastic hinge regionEnhancedEnhanced
Zoppo et al. [46]Discontinuous CFRP strips along the shear spanEnhancedEnhanced
Castillo et al. [47]FRP installation in longitudinal and transverse directions using FRP anchorsEnhancedNot reported
Wang et al. [48]CFRP wrapping in the plastic hinge regionStrength the same, ductility enhancedSame
Wang et al. [49]Externally bonded Strap and full CFRP wrappingLittle enhancement in strength, more in ductilityNot reported
Ghatte et al. [50]Externally bonded CFRPSame strength, ductility enhancedNot reported
Harajli and Rteil [51]CFRP and steel fiber-reinforced concrete (FRC) confinementEnhanced strength and ductilityNot reported
Galal et al. [52]Comparison of CFRP and glass fiber-reinforced polymer (GFRP) wrappingMore enhancement with CFRP wrappingNot reported
Bousias et al. [53]Comparison of RC jacketing and CFRP wrappingMore increase in strength with RC jacketing, whereas more increase in ductility with CFRP wrappingNot reported
Bournas et al. [54]Textile-reinforced mortar versus FRP confinementSimilar strength but enhanced ductilityNot reported
Zoppo et al. [55]CFRP wrapping in the plastic hinge regionStrength same, ductility enhancedSlightly increased
Youm et al. [56]Glass FRP retrofittingEnhancedNot reported
Eshghi and Zanjanizadeh [57]GFRP wraps in splices/critical hinge zoneEnhancedNot reported
Choi et al. [58]GFRP winding wiresEnhancedLower
Ouyang et al. [59]Basalt fiber-reinforced polymer (BFRP) wrappingEnhancedNot reported
Chang et al. [60]Polyester fiber-reinforced polymer wrappingEnhancedNot reported
Dai et al. [61]Comparison of aramid fiber-reinforced polymer (AFRP) and polyethylene terephthalate (PET) wrappingSimilar enhancement for both methodsNot reported
Shape memory alloy (SMA) Wire Jacketing
Choi et al. [62]SMA wire jacketsEnhancedLower
Hybrid Jacketing
Wu et al. [63]GFRP bars embedded in grooves and CFRP sheets in plastic hinge zoneSimilar strength but enhanced ductilitySame
Bournas and Triantafillou [64]Near-surface mounted (NSM) FRP bars (CFRP or GFRP) and CFRP wrappingBoth enhanced but more enhancement in ductility with NSM CFRP barsEnhanced
Sarafraz and Danesh [65]NSM FRP bars and CFRP wrappingEnhancedNot reported
Li et al. [66]NSM GFRP bars and CFRP jacketsEnhancedNot reported
Napoli and Realfonzo [67]Layout 1: NSM rebars with CFRP wrapping in plastic region
Layout 2: NSM rebars with CFRP wrapping and steel angles over the length
More enhancement in strength and ductility for layout 2Lower stiffness for layout 1, higher for layout 2
Seyhan et al. [68]NSM AFRP bars and CFRP sheetsEnhancedNot reported
Fahmy and Wu [69]NSM BFRP bars and externally bonded BFRP sheetEnhancedNot reported
Seifi et al. [70]NSM GFRP bars with CFRP wrapping and NSM steel bars with CFRP wrappingMore enhancement with NSM steel barsEnhanced
Lu et al. [71]Concrete-filled steel tube (CFST)/Concrete-filled CFRP-steel tubes (CFCSTS) with CFRP wrappingEnhancedNot reported
Realfonzo and Napoli [72]CFRP wrapping and steel anglesEnhancedNot reported
Chou et al. [73]FRP wrapped spiral corrugated tube and GFRP wrappingEnhancedNot reported
Cho et al. [74]HPFRC sprayed mortar combined with steel rebarsEnhancedNot reported
Table 2. Summary of studies on the repair of damaged RC columns.
Table 2. Summary of studies on the repair of damaged RC columns.
StudyPre-Damage ConditionRepair MethodStrength and DuctilityInitial Stiffness
RC/Mortar Jacketing
Lehman et al. [3]Severely damaged until failureRepair with headed reinforcement, mechanical couplers and freshly cast concreteLowerLower
Meda et al. [9]Corrosion damagedHPFRC jacketingStrength enhanced onlyNot reported
Rodrigues et al. [13]Damaged until failureRebar welding and casting of micro-concrete in the plastic hinge region.RestoredLower
Yao et al. [14]Corrosion damaged rebarsWrapping with layers of textile-reinforced concrete EnhancedLower
Steel Jacketing
Fakharifar et al. [21]Severely damaged until failureWrapping with thin prestressed steel sheetEnhancedLower
Externally-Bonded FRP Jacketing
Ye et al. [26]Yielding of reinforcementDiscontinuous CFRP wrapping in stripsEnhancement in ductility onlyLower
Haroun and Elsanadedy [75]Damaged until failureFull CFRP wrappingMore enhancement in ductility than strengthSame
Ghosh and Sheikh [76]Damaged until failureCFRP jacketing in plastic hinge region and retrofitting of damaged specimensEnhancedNot reported
Zhou et al. [77]Slight to severe damagePrestressed FRP stripsEnhancedSame
Yang and Wang [78]Yielding and concrete spallingExternally bonded Strap and full CFRP wrappingEnhancedNot reported
Lee et al. [79]Corrosion damagedCFRP wrappingEnhancement in ductility reported onlyNot reported
Aquino and Hawkins [80]Corrosion damagedCFRP wrapping with different layoutsEnhancedNot reported
Kalyoncuoglu et al. [81]Corrosion damagedLayout 1: Mortar
Layout 2: Mortar and CFRP sheet
Layout 1: Increase in strength only
Layout 2: Increase in both strength and ductility
Not reported
Faustino and Chastre [82]Yielding of reinforcementComparison of repair between CFRP only, CFRP with high-strength mortar and CFRP with external longitudinal barsEnhancement in strength by CFRP with high-strength mortar and CFRP with longitudinal bars. CFRP wrapping only increased ductility Not reported
Hashemi et al. [83]Damaged until failureConcrete recasting and CFRP wrapping in the plastic hinge regionStrength not restored, ductility enhancedNot reported
Parks et al. [84]Damaged until failureRepair with CFRP shell, expansive concrete and epoxy-anchored headed barsEnhancedEnhanced
Rodrigues et al. [85]Damaged until failureRebar welding and casting of micro-concrete in the plastic hinge region, followed by wrapping with CFRPEnhancedLower
Bousias et al. [86]Corrosion damageGlass or carbon FRP wrapping Almost similar strength with significantly improved ductility Same
Thermou and Pantazopoulou [87]Concrete cracking and reinforcement buckling, yielding and bond deteriorationExternal glass and carbon FRP jacketingSlight to no enhancement in strength, while significant enhancement in ductilityNot reported
Sheikh and Yau [88]Yielding and concrete spallingCFRP wrapping in the plastic hinge regionEnhancedNot reported
Memon and Sheikh [89]Concrete spalling and rebar yieldingGFRP wrapping in the plastic hinge regionEnhancedNot reported
Seo et al. [90]Predamaged to a ductility of 2.5GFRP strip device comprising GFRP composite with aluminum clip connectorsEnhancedNot reported
Liu and Li [91]Corrosion damagedComparison of CFRP and PET wrappingSimilar enhancement for both methodsNot reported
Peng et al. [92]Yielding of steel rebarsComparison of sprayed BFRP and sprayed HFRPMore enhancement in ductility with HFRP than BFRP. No substantial increase in strengthNot reported
Li and Li [93]Corrosion damagedHFRP wrapping in plastic hinge regionEnhancedSame
Near-Surface Mounted FRP Jacketing
Hasan et al. [94]Partially crackedComparison of NSM rebar strengthening with CFRP wrappingComparatively more enhancement for NSM rebar strengtheningSame
Hybrid Jacketing
Jiang et al. [95]Damaged until failureNSM BFRP bars and externally bonded BFRP sheetStrength enhanced, whereas only ductility restored Restored
Li et al. [96]Corrosion damagedCFRP and steel jacketingEnhancedNot reported
ElSouri and Harajli [97]Severely damagedInternal steel ties and FRP sheetsEnhancedNot reported
Ma and Li [98]Moderately and severely damagedFast curing early strength cement mortar and BFRP sheetDuctility enhanced, whereas strength fully restored for moderately damaged and partially restored for fully damaged columnsLower
Xue et al. [99]Damaged until failureTurned steel rebar and HPFRCRestoredRestored
Rajput et al. [100]Corrosion damagedHPFRC and GFRP wrappingOnly strength enhancedNot reported
Fakharifar et al. [101]Damaged until failureWrapping with thin-cold formed steel sheet and prestressing strandsEnhancedLower
Afshin et al. [102]Corrosion damagedCFRP sheet with steel profileEnhanced strength, but no significant improvement in ductilityEnhanced
Table 3. Summary of benefits/drawbacks of the different repair and strengthening techniques.
Table 3. Summary of benefits/drawbacks of the different repair and strengthening techniques.
Strengthening MethodBenefitsDrawbacks
RC/Mortar Jacketing
  • Commonly used/available material
  • Familiarity of practicing engineers with the material
  • Ability of RC to take any shape
  • Increases both strength and ductility
  • Expensive, labor intensive and time consuming due to formwork installation
  • Change in cross-sectional size leading to change in stiffness and seismic demands
  • Increase in ductility is small due to brittle nature of concrete
  • Disruption of occupancy
Steel Jacketing
  • Ductile and commonly used/available material
  • Excellent confinement leading to considerable increase in both strength and ductility
  • Expensive and labor intensive.
  • Rusting and corrosion
  • Change in cross-sectional size leading to change in stiffness and seismic demands
  • Heavy weight
Externally Bonded FRP Jacketing
  • Ease and speed of installation
  • Corrosion resistance
  • Minimum modification to geometry and aesthetics of structure
  • Minimum disruption of occupancy
  • High durability, high strength-to-weight ratio
  • Better work safety and minimum risk hazard
  • Enhancement in both strength/ductility
  • Costly material (but overall cost is low due to small cost of transportation and installation)
  • Low efficiency (30–35%) due to debonding
  • Poor properties on exposure to high temperature and wet environment
  • Increase in strength is relatively small
Near-Surface Mounted FRP or Steel Reinforcement
  • Less prone to debonding
  • Minimum modification to geometry and aesthetics of structure
  • Less prone to mechanical impact and accidental damage due to protection by concrete cover
  • Aesthetics of the structure remain unchanged
  • Enhances strength considerably
  • Costly material (but overall cost is low due to small cost of transportation and installation)
  • Comparatively more labor intensive in comparison to externally bonded FRP, but lesser than RC or steel jacketing
  • Not much increase in ductility
Shape Memory Alloy (SMA) Wire Jacketing
  • Fast installation
  • No need for adhesive
  • No danger of peel off
  • Super elastic and durable
  • Increases both the strength and ductility
  • Costly material
  • Ineffective composite action with concrete
  • Enhancement in strength is relatively small
Hybrid Jacketing
  • Fast installation
  • Minimum modification to geometry and aesthetics of structure
  • High durability
  • Significant enhancement in both strength and ductility
  • Costly material
  • Comparatively labor intensive as it combines two different retrofitting techniques
Table 4. Comparison matrix of different strengthening and repairing techniques for RC columns.
Table 4. Comparison matrix of different strengthening and repairing techniques for RC columns.
Strengthening MethodEffect on StrengthEffect on DuctilityEffect on StiffnessCost of StrengtheningAesthetics/Impact to FloorplanImpact to Occupants
RC JacketingIncreaseIncreaseUnchanged/increasedVery highPoorVery high
Steel JacketingSignificant increaseSignificant increaseUnchanged/increasedVery highModerateHigh
Externally Bonded FRP JacketingIncreaseSignificant increaseUnchangedModerateGoodModerate
Near-Surface Mounted FRP or Steel ReinforcementSignificant increaseIncreaseUnchangedModerateGoodHigh
Shape Memory Alloy (SMA) Wire JacketsIncreaseIncreaseDecreaseHighModerateModerate to high
Hybrid JacketingSignificant increaseSignificant increaseUnchanged/increasedHighModerateHigh to very high

Share and Cite

MDPI and ACS Style

Raza, S.; Khan, M.K.I.; Menegon, S.J.; Tsang, H.-H.; Wilson, J.L. Strengthening and Repair of Reinforced Concrete Columns by Jacketing: State-of-the-Art Review. Sustainability 2019, 11, 3208. https://0-doi-org.brum.beds.ac.uk/10.3390/su11113208

AMA Style

Raza S, Khan MKI, Menegon SJ, Tsang H-H, Wilson JL. Strengthening and Repair of Reinforced Concrete Columns by Jacketing: State-of-the-Art Review. Sustainability. 2019; 11(11):3208. https://0-doi-org.brum.beds.ac.uk/10.3390/su11113208

Chicago/Turabian Style

Raza, Saim, Muhammad K. I. Khan, Scott J. Menegon, Hing-Ho Tsang, and John L. Wilson. 2019. "Strengthening and Repair of Reinforced Concrete Columns by Jacketing: State-of-the-Art Review" Sustainability 11, no. 11: 3208. https://0-doi-org.brum.beds.ac.uk/10.3390/su11113208

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop