Article

Mathematical Modeling of Efficiency Evaluation of Double-Pass Parallel Flow Solar Air Heater

1
Department of Mechanical Engineering, School of Engineering, University of Petroleum and Energy Studies India, Dehradun 248007, India
2
Technical Education Department Uttar Pradesh, Kanpur 208024, India
3
Energy Centre, Maulana Azad National Institute of Technology, Bhopal 462003, India
4
CSIR—Central Building Research Institute, Roorkee 247667, India
5
Department of Engineering, University of Rome Niccolò Cusano, 00166 Roma, Italy
*
Authors to whom correspondence should be addressed.
Sustainability 2022, 14(17), 10535; https://0-doi-org.brum.beds.ac.uk/10.3390/su141710535
Submission received: 25 July 2022 / Revised: 18 August 2022 / Accepted: 19 August 2022 / Published: 24 August 2022
(This article belongs to the Special Issue Solar Energy Utilization and Sustainable Development)

Abstract

:
To investigate the influencing range and optimize values of different operational and system parameters on the double-pass parallel flow solar air heater’s (DPPFSAH) thermal, effective, and exergetic efficiencies, an iterative method was used to analyze the governing energy equations using a theoretical model written in MATLAB based on the Nusselt number (Nu) and friction factor (f) correlations developed in the work performed earlier. A comparison between double-pass and single-pass SAHs for mathematical and experimental outcomes was conducted, and the results were found to be fairly consistent. According to the thermo-hydraulic performance indicators, similar to single-pass SAHs, perforated multi-V rib-roughened DPPFSAHs achieve optimum thermal performance for lower Reynolds numbers, which does not change much as the Reynolds number increases above 18,000. This finding can be taken into account when designing any DPPFSAH.

1. Introduction

Because of its simplistic design, simple operation, easy maintenance, and low initial investment, a solar collector for air heating is particularly beneficial for applications requiring low thermal energy. The heat a working fluid absorbs from a solar collector determines how well the collector performs. By raising the heat transfer coefficient (h) or the heat transfer surface area in between the absorber plate and the moving air, the solar air heater (SAH) efficiency can be improved [1,2].
The flat-plate SAH thermal efficiency (ηth) is decreased due to the low h value between the absorber plate and the airflow. A laminar sub-layer that forms next to the absorber surface when air passes through the duct of an SAH reduces heat transfer to the air stream and, consequently, the ηth. The laminar-to-turbulent conversion of the boundary layer zone is achieved by applying artificial roughness to the absorber plate on one or both sides. That leads to a rise in h values and the rate of heat transfers in the duct.
Artificial roughness can be produced on the SAH absorber surface by providing meshing or extended characters such as fines, blockages, vortex generators, tabulators, or ribs. Dimensional and geometric configurations for different types of ribs were investigated by various research scholars. The Thermo-Hydraulic Performance (THP) of an SAH is noticeably improved by multi-V shape ribs [3]. Excessive turbulence may result in higher power demands for airflow, demanding a careful selection of the roughness element and its design because the energy needed to induce turbulence comes from the blower or fan. Arrangements such as the dimensioning optimization of ribs, gaps between ribs, staggering arrangement between gaps, and partial and full perforation in ribs reduce the friction losses and improve the mixing properties of the working fluid, resulting in the better THP of an SAH.
Double-Pass SAHs (DPSAH) considerably increase the collector surface area and therefore offer considerable gains in heat transfer [4]. Double-Pass SAHs with crossflow [5], recycling [6], and parallel flow [7,8] are the DPSAH arrangements that were utilized as the primary factors that impacted the performance. Yadav and Prasad [9] discovered that the DPPFSAH’s rate of heat gain was 8–10% higher than a smooth duct. Hernández and Quinonez [10] observed that in the case of DPSAHs, parallel flow is more advantageous than counter flow because the airflow does not gain significant useful heat by circling beneath the base plate while having a large power requirement due to pressure drops.
Singh et al. [11,12] analysed the effect of perforation for a continuous rib in multi-v geometry in Single-Pass SAHs (SPSAH) and Double-Pass Parallel Flow SAHs (DPPFSAH) and observed a significant improvement because of the application of perforation. This work further extended to the analyzing the effect of variations in the open area ratio (β) and the relative roughness width (W/w) and found the optimum value of β for peak performance in SPSAHs and DPPFSAHs [13,14]. Various research on perforation, such as half and full perforation [15], hole-circularity [16,17,18], proportion of β, and hole positioning [19], has been conducted to examine the perforation’s influence on flow behaviour. The β value and the recirculation time have shown a significant impact on SAHs’ performance [20]. The impact of perforation hole-circularity in V-shaped blockages on THPP and a correlation for SAHs have been developed by Alam et al. [17].
A mathematical model for the energy and exergy analysis of SAHs was developed by Duffie and Beckman [21]. Hap and Phu conducted a series of experiments to develop mathematical modeling for the energy analysis of single-pass [22,23,24], double-pass [25], and multi-pass [26] SAHs and found a strong correlation between experimental and mathematical models for different roughness geometries. Hernández and Quiñonez [10] also developed an analytical model for the thermal performance of a double-pass parallel flow solar air heater (DPPFSAH) and a double-pass counter flow SAH (DPCFSAH) and observed that an increase in air velocity also improves the heat transfer rate, and the proposed expression can be used for further computational modeling. Kumar and Saini [27] developed correlations for the Nusselt number (Nu) and friction factor (f) for an SAH having dimple-impeachments on the absorber plate. An Nu and f correlation for DPSAHs with V-rib roughness was developed by Varun et al. [28]. Ravi and Saini [29] developed Nu and f correlations for counter-flow DPSAH with discrete multi-V ribs with staggering. In their exergy-based study of an SAH duct having W-ribs, Patel and Lanjewar [30] note that the relative roughness height (e/Dh) = 0.03375 and the angle of attack (α) = 60o produced the largest increase in the exergetic efficiency (ηexg) of the rough SAH when compared with the smooth surface, that is, 51%. An exergy analysis of an SAH with double-V incisions in twisted tape was carried out by Kumar [31]. In SAHs with broken arc-ribs with staggering sections, Meena et al. [32] and Saini et al. [8] measured the heat transmission and friction properties. Using numerical simulations for ribbed triangular SAHs, Kumar and Kumar [33] studied the performance enhancements and the correlations for the friction factors and heat transport. Kumar et al. [34]. conducted an experimental investigation of a DPSAH with multiple-C-shaped roughness on an SAH.
The above literature reveals that the application of DPPFSAHs reduces drag forces to a minimal level, which is responsible for high pumping power while having optimum thermal effectiveness [10]. The rapid air flow rate of the supplementary streams via holes created more turbulence during detachment and reattachment, which enhances the THP of SAH [20,35,36]. Although perforation in fins and the extended surface is around a decade-old concept, perforation in the ribs (e/Dh ≈ 0.043) was newly introduced by Singh et al. [12,13], and no single work is available that can specify the effect of perforation variations on influencing the range and optimized values of different operational and system parameters in the case of a DPPFSAH.
Previous researchers have shown a great deal of interest in the study of DPPFSAHs’ thermal performance. The current work aims to focus on developing a mathematical model and conducting an analytical study of DPPFSAHs with perforated multi-V ribs as an artificial roughness to find out the effective range of the system and operating parameters for optimum thermal, effective, and exergy performances. To validate the model, a comparison between the results of the mathematical and experimental outcomes for single-pass and double-pass SAHs was also compared to the research previously conducted by the authors.
This work will provide step-by-step methodology for efficiency prediction and explains the effect of individual flow and system parameters on thermal efficiency and their effective range in different operating conditions, which will help researchers interested in this area. This study also gives a valid reason to choose different efficiencies in different working conditions and also explains why the effective efficiency criterion in thermo-hydraulic optimization has solid recommendations for calculating the efficiency of DPPFSAHs roughened with perforated multi-V ribs.

2. Experimental Setup and Model for DPPFSAH

A DPPFSAH test rig is created by ASHRAE guidelines (AHSRAE 93-77, 1977). A detailed description of the setup, fixed, and variable parameters is discussed in a previous study conducted by Singh et al. [12] of this study. Details of the operating and dimensional parameters of this study are mentioned in Table 1 and Table 2.
Figure 1a,b shows the Schematic and cross-sectional view of a DPPFSAH with perforated multi-V rib roughness, while Figure 2 shows the thermal resistance circuit of the DPPFSAH.

Heat Transfer Modes and Assumptions for Boundary Condition

For a rectangular SAH duct, the primary assumptions considered for heat transfer modes include a uniform heat flux distribution on glass cover; conductive heat transfer between the glass covering, base plate, and rear surface; and convective heat transfer inside the airstream and the glass covering or base plate [28,29]. To simplify the analysis and construction of the mathematical model, assumptions for governing equations include: the flow condition is turbulent incompressible, a temperature-independent and three-dimensional flow under quasi-steady state under leak-free conditions, and a perfectly insulated test section.

3. Thermo-Hydraulic Performance of DPPFSAH

The ratio of the working fluid’s rate of efficient thermal gain (Qu) to the amount of sun irradiation (I) attained by the collector’s heated surface is known as the thermal efficiency (ηth) of SAH [1]. It can be expressed as:
η t h = Q u / A p   × I
Q u can be calculated as [37]:
Q u = I   τ α U L T p m T a
Q u can also be calculated by using Bliss’s [38] heat removal factor (FR) for incoming air temperature, as follows:
Q u = F R I   τ α U L T f i   T a  
Agarwal and Larson [39] define the SAH’s thermal performance for ambient air as:
Q u = F o I τ α U L T o T a ]  
The collector heat removal factor (F0) for outlet air is the ratio of the actual to maximum feasible heat transfer rate [40] and is expressed as:
F 0 = m C p A p U L exp F U L A p m C p 1
The SAH efficiency factor (F′) is determined by dividing the actual tangible heat collection rate by the rate that would be possible if the entire absorber plate were assumed to be at input air temperature. It is calculable as follows:
F = 1 + U L h
The relation for η t h   can be derived from Equations (1) and (6) and can be expressed as:
η t h = F o   τ α U L ( T f o T f i ) I

4. System and Operational Parameters

To examine the thermal efficiency (ηth) and Efficiency Enhancement Factor (EEF) of the DPPFSAH with perforated multi V-ribs and to determine the optimum values of the parameters that obtain the optimum thermal efficiency, these parameters can be divided into fixed and variable categories.

4.1. Fixed Parameters

The DPPFSAH’s fixed parameters are divided into two groups: fixed system parameters and fixed operational parameters. The ambient air temperature, inlet air temperature, and wind velocity are fixed operational parameters of the heater, whereas fixed system parameters include the different components of the SAH and the associated thermos-physical characteristic parameters. Table 1 shows the values of all of these parameters with units as suggested by Beckman et al. [41] and used in experimental setup by Singh et al. [12].

4.2. Variable Parameters

Variable system parameters include W/w and β, whereas variable operational parameters include flow parameters such as Re, ṁ, ΔT/I, and I. ΔT/I determines the gain in air temperature streaming out of the SAH duct and is specified as the increase in air temperature for a given degree of solar irradiance. As a result, while constructing an SAH, the temperature increase parameter is critical in determining the temperature range for a specific commercial or non-commercial application. The thermal performance of a DPPFSAH having various perforated multi-V roughened heated absorber plates has been estimated for the range of variable parameters given in Table 2.
The simple regression equations were used to evaluate the thermo-physical properties of air:
μ = 1.81 10 5 T f m 293 0.735   N / sm 2
C p = 1006 T f m 293 0.0155         J / kgK
K = 0.0257 T f m 293 0.086         W / mK
ρ = 97500 287.045 T f m     kg / m 3
P r = μ C p K

5. Steps for Efficiency Prediction of DPPFSAH

The thermal performance of a DPPFSAH with artificially roughened perforated multi-V ribs was predicted using a computer program written in MATLAB. The prediction used the correlations for Nu as a function of roughness and the operating parameters discussed in the previous work carried out by Singh et al. [12] and compared with results of SPSAH [13].
Step 1. During the iterative process, a fixed set of geometrical and roughness values chosen in accordance with Table 2 are used, and varying variables such as W/w, β, Re, ΔT/I, and I values are taken into consideration in accordance with Table 2.
Step 2. The plate area can be found as:
A p = W × L
Step 3. The air temperature at the outlet (Tfo) and the change in air temperature (ΔT) is determined through the air inlet temperature ( T f i   ), as follows:
Δ T = Δ T / I I = T a i r o u t T a i n   T f o =   Δ T + T f i  
The air’s bulk mean temperature is calculated as:
T f m = ( T f o + T f i ) / 2
The mean absorber plate is calculated as:
T p m = ( T f o + T f i ) / 2 + 10
Step 4. The top loss coefficient (UT) is derived by the Klein [40] and Datta [42] correlation, as follows:
1 U T = σ T p m 2 + T g 2 T p m + T g 1 ε p + 1 ε g 1 + K a N u t L g 1 + σ ε g T p m 2 + T g 2 T p m + T g + h w 1 + t g k g  
where the temperature of the glass ( T g ) is calculated as [43]:
T g = F 1 T p m + c T a 1 + F 1
where:
F 1 = 12 10 8 T a + 0.2   T p m 3 + h w 1 + 0.3 t g 1 [ 6 10 8 ε p + 0.028 T p m + 0.5 T a 3 + 0.6 L g 0.2 T p m T a c o s β 0.25 1
and
C c = T s T a + h w 3.5 / 1 + h w 3.5
T s = 0.0522 T a 1.5
N u t = 1 + 1.44 1 1708 R a c o s β 1 1708 s i n 1.8 β 1.6 R a c o s β + R a c o s β 5830 1 3 1
R a = ξ g L 3 g Δ T / v α
where ξ is the volumetric coefficient of expansion, 1/K, computed as [42]:
ξ = 1 T f o + T f i 2
where g—Gravitational constant, m/s2; ΔT—temperature differential, K; υ—kinematic viscosity, m2/s; Ra—the Rayleigh number; and α—thermal diffusivity, m2·s−1.
Step 5. The back loss coefficient (UB) is the ratio of thermal-conductivity (kins) and thickness (tins) of insulation [44]:
U B = k i n s t i n s
Step 6. The edge loss coefficient (UE) is calculated using the collector area (Ac), insulator thermal conductivity (kins), and thickness (tins) as inputs, given as in [44].
Finally,
U L = U T + U B + U E
Step 7. The useful heat in duct is calculated as:
Q u 1 = I   τ α U L T p m T a A p  
For the DPPFSAH, the Re value is determined as:
R e = ρ V D / μ
Step 8. For the SPSAH and DPPFSAH, the Nu is determined by using empirical correlation developed by Singh et al. [12,14].
For an SPSAH:
N u = 0.0324   R e 0.9648 β 0.2338 E x p 1 E 12   L n β 2 W w 0.102 E x p 3 E 14 L n W w 2
For a DPSAH:
N u = 0.0769   R e 0.8953 β 0.2417 E x p 2 E 13   L n β 2 W w 0.1244 E x p 7 E 15 L n W w 2
Step 9. The h value is determined by using the Nu in step 9 using the calculation given below [45]:
h = N u   k / D
D is the hydraulic diameter in meters, which is derived using the formula:
D = 4 W H / 2 W + 2 H
Step 10. The plate efficiency factor is determined as [42]:
F = h / h + U L
Step 11. The heat removal factor is calculated as follows [42]:
F 0 = m C p A p U L exp F A p U L m C p 1
Step 12. The useful heat gain (Qu2) per unit area of the collector calculated as [37]:
Q u 2 = A p F o I τ α U L T f o T f i
Step 13. By using steps 7 and 12, Qu1 and Qu2 are calculated and compared. If the predicted values of these two terms are not near enough, i.e., Q u 1 Q u 1 Q u 1   > 0.1%, then the next mean temperature (Tpm) of the absorber plate is revised as:
T p m = T a + I τ α Q u 2 A p U L
Step 14. Equation (34) uses the value of Tpm derived in Equation (16), and the computations are repeated from step 5 to step 14. Qu1 and Qu2 have been iterated until they are near enough, i.e., (Qu1Qu2 < 0.1% of Qu1).
Step 15. The roughened double-pass SAH’s η t h is calculated as:
η t h = Q u / I A p
Qu is the average heat gain, which is calculated as:
Q u = ( Q u 1 + Q u 2 ) / 2
Step 16. The f value for a DPPFSAH is determined by using the correlation developed by Singh et al. [12,14], which is presented below.
For an SPSAH:
f = 1.6608   R e 0.529 β 0.2826   E x p 2 E 13 L n β 2 W w 0.1295 E x p 2 E 14 L n W w 2
For a DPPFSAH:
f = 0.4234   R e 0.2964 β 0.3897   E x p 1 E 14 L n β 2 W w 0.1836 E x p 1 E 14 L n W w 2
Step 17. The pressure drop (ΔP)d in the duct is calculated as:
Δ P d = 4 f L ρ V 2 / 2 D
Step 18. The power requirement of the blower (Pm) is calculated as:
P m = Δ P d / ρ
Step 19. The thermal efficiency is calculated as:
η t h = F o τ α U L T o T i / I
Step 20. The effective efficiency, ηeff, is determined as:
η e f f = Q u P m / C / I A p
where
C = η t   . η t r   .   η m   .   η f  
The C value, proposed by Corter-Piacentini [46], is 0.180 (where ηf = 0.65; ηm = 0.88; ηtr = 0.92; and ηth = 0.35).
Step 21. The mean fluid temperature (Tfm) is calculated as:
T f m = ( T f o T f i ) / ln T f o / T f i  
Step 22. The Carnot efficiency is determined as:
η c = 1 T a / T f m
Step 23. The Net exergy-flow ( E n ) is calculated as:
E n = I A P η t h η c P m 1 η c
Step 24. The Exergy-rate ( E s )   associated with solar irradiation is calculated as:
E s = I ( 1 T a / T s u n )
Step 25. The exergetic efficiency ( η e x g ) is determined as:
η e x g = E n / E s
Step 26. To cover the whole range of roughness and operating parameters as shown in Table 1 and Table 2, calculations are performed from step 2 to step 25 for all possible combinations of system and operational parameters. Figure 3 shows the process-flow diagram of the computer program developed in MATLAB that performs all of the computations specified in the preceding sections.

6. Results and Discussion

The present quantitative analysis investigated the characterization of an SAH with an artificially rough surface using predefined parameters and their range, as shown in Table 1 and Table 2. Plotted for the ΔT/I and Re are the findings generated for thermal, effective, and exergetic efficiencies. The heated flat plate’s roughness created a second air route, reduced the reattachment zone, improved fluid blending, and improved the THP of SAH.

6.1. Effect of Flow and System Parameters on Thermal Efficiency

6.1.1. Effect of Reynolds Number (Re)

Figure 4a depicts the impact of Re on the ηth of a DPPFSAH roughened with varied perforated multi-V ribs for various specified roughness levels. The values of β = 0.27 and W/w = 6 were chosen as the optimum roughness parameters. The ηth of the smooth and roughened collectors increase with increase in the Re values in all instances of the SPSAH and the DPPFSAH. The improvement in the h value between the base plate and air caused by the rise in Re can be used to explain these behaviours. Roughness patterns further enhance the SPSAH’s and DPPFSAH’s ηth. In case of SPSAHs and DPPFSAHs, the ηth improve from 69.66% to 80.13% and 74.74% to 86.57%, respectively, for a perforated multi-V rib roughness of e/D = 0.043, β = 0.27, P/e = 10 α = 60°, W/w = 6, W/H = 12, and I = 1000 W/m2 corresponding to an Re from 2000 to 18,000. On the other hand, for a smooth collector, the ηth lies between 27.66% and 65.19%, corresponding to an Re from 2000 to 18,000, respectively.
Figure 4b shows a new plot of all the ηth values with a relationship of the ΔT/I. As the ΔT/I increased, it was discovered that the ηth of the SPSAH and DPPFSAH rapidly decreased. The temperature of the entering fluid increases, the thermal gradient between the base plate and the airstream decreases. Due to this, the base plate and glass cover’s average temperature increase, which increases the amount of heat lost to the environment while reducing the amount of heat gained, which is actually useful. This lowers the thermal productivity and effectiveness of the SPSAH and DPPFSAH.

6.1.2. Effect of Relative Roughness Width (W/w)

The graph of ηth as a function of ΔT/I for the SPSAH and the DPPFSAH is shown in Figure 5a,b. In both scenarios, the ηth declines and is found to be lowest at W/w = 2 after increasing with the increase in W/w up to 6 and then dropping with the increasing W/w values. The greatest ηth for both the SPSAH and the DPPFSAH was found to be 80.13% for the SPSAH and 86.57% for the DPPFSAH at W/w = 6 and β = 0.27.

6.1.3. Effect of Open Area Ratio (β)

Figure 6a,b show that the ηth rises with the increase in β, reaches a maximum at 0.27, and then slightly declines as β rises further. It has been discovered that raising the β value results in more turbulence and secondary flow mixing in the vicinity of the perforated ribs, which enhances fluid mixing and lowers the thermal barrier due to the laminar sub-layer, boosting the h value. In addition, as β rises over 0.27, Qu decreases because secondary air can now be accessed through perforations, and the upper part of the rib starts to behave like a stagger, making it harder for fluid to mix effectively [20,47].

6.2. Efficiency Enhancement Factor (EEF)

The efficiency enhancement factor (EEF) is the ratio of the ηth of an SAH with and without artificial roughness operating under similar conditions:
Efficiency   Enhancement   factor   EEF = η t h R o u g h   η t h S m o o t h  
Figure 7a,b show the effect of W/w and β on EFF as a function of ΔT/I for a DPPFSA, and the largest and smallest EEFs for a DPPFSAH are 2.37 and 1.2, respectively.

6.3. Effect of Insolation on EEF

The EEF presented with the insolation levels of 600, 800, and 1000 W/m2 have been considered. From Figure 8, it is evidently observed that the EEF increased with the rise in I value. In addition, as the ΔT/I increased, the EEF increases for a given value of I. The maximum and minimum efficiency improvement factors were found at insolation values of 1000 W/m2 and 600 W/m2.

7. Effective Efficiency (ηeff) Criteria for DPPFSAH

The true effectiveness of an SAH can be expressed in terms of “ηeff”, which accounts for the useful energy gain and equivalent heat required to generate equal mechanical energy to overcome pressure losses, as per Cortes and Piacentini [46]. For a DPPFSAH, the optimum value of ηeff was acheived at a W/w of 6 when the ΔT/I was more than 0.01107 Km2/W. Similarly, for ΔT/I values less than 0.00371 Km2/W, the DPPFSAH’s smooth collectors perform better than roughened collectors in SPSAHs and DPPFSAHs. Figure 9a,b show that, for a given value of W/w, the DPPFSAH’s ηeff improves as Re increases, reaches an optimum value, and then starts decreasing as the Re rises further. The optimum ηeff is found at W/w = 6, Re = 8527. The DPPFSAH roughened plate has a higher ηeff for Re greater than 19,025. As a result, it is discovered that the roughness geometry in the form of a perforated multi-V shaped rib pattern performs better at lower Re values. While Influence of β on ηeff as a function of ΔT/I and Re for DPPFSAH is shown in Figure 10a,b and the range of parameters β and ΔT/I for highest ηeff for different combination of DPPFSAH is shown in Table 3.
For varying values of Re and ΔT/I, Table 4 shows the geometric parameters that correlate to the highest value of ηeff. System and design characteristics such as e/D, β, p/e, α, and I are kept constant.

Geometric Parameter Optimization Using the Effective Efficiency Criteria

The optimum geometric parameter is an arrangement of geometric parameter values (W/w, β) associated with the best value of effective efficiency (ηeff) for a given range of design parameters (ΔT/I, I). For different values of solar radiation intensity (I), Figure 11a shows the variation in optimum values of W/w with ΔT/I for different values of I. For ΔT/I < 0.009572 Km2/W, the best value of W/w is 2 for a DPPFSAH. For a DPPFSAH, the ideal W/w is 6 for ΔT/I > 0.01128 K-m2/W for the entire range of I. However, the optimum value of W/w for a DPPFSAH is discovered to be a function of ΔT/I (ranging between 0.009572 K-m2/W and 0.01128 K-m2/W) and I. Table 5 shows a summary of the findings. While Figure 11b shows the variation of optimum values of β as a function of ΔT/I for different I values. The β = 0.21 represents the optimum settings for ΔT/I < 0.00794 K-m2/W for a DPPFSAH for the entire range of I studied. The β = 0.27 for ΔT/I > 0.01091 Km2/W reflects the best conditions for all the selected I values.

8. Exergetic Efficiency (ηexg) Criterion for DPPFSAH

Atfeld et al. [48] proposed an exergetic efficiency criterion based on the second law of thermodynamics to characterize the optimum values of geometric and operating characteristics. The value of W/w corresponding to maximal ηexg varies with ΔT/I, as shown in Figure 12a. For a DPPFSAH, the optimum value of ηexg was reached at a W/w of 6, corresponding to a ΔT/I value greater 0.15298 Km2/W, respectively. The smooth DPPFSAH shows a better ηexg compared to roughened DPPFSAH. Figure 12b depicts the variation in ηexg with Re for different values of W/w and fixed values of other parameters, the optimum value of ηexg has been obtained at W/w = 6 for Re < 3685, whereas for Re > 9228, the smooth DPPFSAH shows better ηexg compared to roughened DPPFSAH. The details of optimum range are given in Table 6.
Figure 13a demonstrates that the maximum value of ηexg was obtained for ΔT/I > 0.0169 Km2/W at β = 0.27, whereas the maximum value of ηexg for a smooth DPPFSAH were obtained for ΔT/I < 0.01017 Km2/W. The detailed range of parameters and optimum range of β are given in Table 7. Figure 13b represents the variation in ηexg with β as a function of Re. It is observed that the optimum value of ηexg for smooth DPPFSAH occurs for Re > 8955.

Geometric Parameter Optimization Using the Exergetic Efficiency (ηexg) Criterion

The optimum value of W/w on the basis of the highest ηexg has been drawn in Figure 14a for a DPPFSAH, for a given range of ΔT/I. The W/w value of 2 indicates the best condition for the DPPFSAH, ΔT/I < 0.006051 Km2/W, for the entire range of I, i.e., from 600 to 1000 W/m2. Furthermore, for all values of I, ΔT/I > 0.008084 Km2/W constitutes the optimal condition for a W/w value of 6. For a DPPFSAH, the optimum value of W/w is a function of I for ΔT/I values between 0.006051 Km2/W and 0.008084 Km2/W, respectively. Figure 14b depicts the optimum values of β for different values of ΔT/I and I. For the value of β of 0.21, the optimum values are obtained for ΔT/I values up to 0.00794 Km2/W for DPPFSAH. For the values of ΔT/I above 0.01091 Km2/W, a β value of 0.31 gives the optimum results for a DPPFSAH. However, for ΔT/I values between 0.00794 Km2/W and 0.01091 Km2/W, the optimum value of β is a function of I. The ηexg criterion plays a major role in selecting the optimum values of geometric parameters such as W/w and β based on design parameters such as ΔT/I and I, according to the above discussion. For a particular range of ΔT/I and I, a set of optimum geometric parameters can now be picked from Table 8.

9. Comparison of Optimization Criteria

In order to maximize heat transfer while utilising the lowest amount of blowing or pumping energy, the roughness geometry must be chosen carefully. The optimal values for a group of geometric parameters can be chosen to achieve this objective. The three optimizing criteria described in this study include the ηth, ηeff, and ηexg criteria.
The single geometrical parameter that is optimal for all chosen values of ΔT/I is provided by the ηth criteria. As a conclusion, Table 9 demonstrate that the best artificial roughness geometries for a DPPFSAH is a combination of the best values of the design variables, namely, a W/w of 6 and a β of 0.27. Although no single pairing of design parameters displays the optimal values for the entire range of the ΔT/I in the case of the ηeff requirements and the ηexg standards, it is noted that no single pairing of design parameters displays the optimal values for all chosen values of the ΔT/I. An artificially roughened DPPFSAH with β = 0.27 and W/w = 6 outperforms all other permutations of DPPFSAHs on all three criteria.
The design parameters of Figure 15a,b, which show a nearly identical maximum solution for I = 1000 W/m2 generated using the ηeff and ηexg criteria, were used to calculate the range of ΔT/I given in Table 9. According to the ηeff and ηexg criteria for various amounts of solar irradiance, Table 10 illustrates the ΔT/I range where the optimal geometric parameter values vary. As shown in the analysis, the optimal values of geometric parameters depend directly on the optimization criteria employed. Therefore, selecting the factors to take into account in order to improve the desired results of SAH becomes crucial. The blower power required to move air through the collector is not included in ηth metrics; rather, they solely take into account gains in thermal energy. In order to maximise the performance of SAH, the thermo-hydraulic considerations, specifically ηeff and ηexg, should be applied.
Only in cases where there is a thermo-hydraulic conversion of heat into work is the ηexg criterion applicable. Due to their narrow temperature range of operation, SAHs are not suitable for work generation. It has been demonstrated that the total exergy flow has negative values in some low-temperature uses. The ηexg criterion is therefore crucial when calculating thermal power at high average temperature. Additionally, the ηeff requirement takes into account the rise in useable heat energy, which is constrained by the energy required to supply blowers the energy to make up for pressure losses. Thus, from the perspective of thermo-hydraulic optimization, the ηeff criterion has been suggested for DPPFSAHs roughened with perforated multi-V ribs.

10. Conclusions

Mathematical modeling and parametric optimization of a DPPFSAH using thermal, effective, and energetic efficiency assessments was completed for a perforated multi-V roughened base plate. As an outcome of the optimization procedure carried out for the design parameters for various operating scenarios under the assumption of ηeff, the optimal values are shown.
The primary conclusions drawn from the results of this study shows that the THP of the DPPFSAH is improved by perforation in multi-V rib roughness because it produces secondary passages for flowing fluids and speeds up fluid mixing. According to the analytical findings, Re and ΔT/I have a substantial impact on how the geometric properties of the DPPFSAH (W/w and β), influencing heat transfer efficiency. With W/w = 6 and β = 0.27, the optimum value of ηth was found to be 86.57% for rough surfaces and 74.74% for smooth ducts. For a DPPFSAH, the optimum design noted EEF = 2.37 at W/w = 6, β = 0.27 and I = 1000 W/m2. The blower power is considerable at lower ΔT/I values; hence, the EEF increases as the Re and ΔT/I intensities increase. It is also observed that smooth collectors perform better than roughened DPPFSAH collectors for ΔT/I values below 0.00371 Km2/W, while the best value of ηeff was achieved at W/w = 6, when ΔT/I >0.01107 Km2/W. Similar to ηeff, which becomes better as Re rises and reaches its peak value for W/w = 6 at Re = 8527, ηeff then starts to fall for all W/w values as the Re values continue to rise. In comparison to the roughened DPPFSAH, the smooth DPPFSAH has a higher ηeff for an Re > 19,025.
For DPPFSAHs, when the ΔT/I is more than 0.01091 Km2/W, the effect of ΔT/I on ηeff as a function of β attends the highest value of ηeff at β = 0.27, and once the ΔT/I < 0.00359 Km2/W, the smooth collector outperforms the roughened DPPFSAH. The smooth DPPFSAH has a larger ηeff for an Re > 18,821, and the best ηeff is found for β = 0.27 at Re = 8527. The smooth DPPFSAH also demonstrates higher ηexg than the roughened DPFPSAH with ΔT/I < 0.006985 Km2/W, with the optimal value of ηexg being attained at a W/w = 6 and at ΔT/I above 0.015298 Km2/W. The maximum value of ηexg has been reached for Re < 3685 and W/w = 6, but for Re > 9228, the smooth DPPFSAH indicates a higher ηexg in comparison to the roughened DPPFSAH. The optimum value of ηexg has been obtained for 0.0169 < ΔT/I K.m2/W at β = 0.27, whereas the highest value of ηexg for smooth SPSAH has been obtained for ΔT/I < 0.00359 K.m2/W. As a consequence, it is found that a perforated multi-V shaped rib patterns roughness architecture works better at smaller Re levels and larger ΔT/I values. The effective efficiency ηeff criterion was found for a DPPFSAH roughened with perforated multi-V ribs. The Re range of 2000–18,000 for DPPFSAH can be designed using the results of the current study.

Author Contributions

The significant contributions of authors are as follows: conceptualization: V.P.S., and S.J.; methodology: V.P.S. and S.J.; setup development: V.P.S. and S.J.; validation: V.P.S., A.K. (Ashish Karn), and C.S.M.; formal analysis of setup and testing practices: A.K. (Ashwani Kumar), G.D., A.K. (Ashish Karn), R.C., and C.S.M.; testing, investigation, and data collection: V.P.S.; resources: S.J., G.D., and C.S.M.; data curation: V.P.S. and A.K. (Ashwani Kumar); writing—original draft: V.P.S., C.S.M., and R.C.; writing—review and editing: V.P.S., S.J., C.S.M., A.K. (Ashwani Kumar), R.C., and A.K. (Ashish Karn); visualization: S.J., G.D., and C.S.M.; supervision: S.J., C.S.M., and R.C.; project administration: S.J. and R.C. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.

Nomenclature

Details of symbolsGreek symbols
AArea, (m2)ΔDrop/gradient
CdCoefficient of dischargeΔPartial
PMean static pressure N/m2ηEfficiency
HHeight, (m) Emissivity
hHeat-transfer coefficient (W/m2·°C)υKinematic viscosity, (m2/s)
ISolar Irradiance (W/m2)αAbsorptivity
kThermal conductivity (W/m°C)σStefan–Boltzmann constant (W/m2·K4)
tThickness (m)ρAir density, (kg/m3)
m ˙ Air mass-flow rate, (kg/s) αAngle of attack, (o)
PPitch distance (m)βCollector slope (o), Open area ratio
QThermal energy transferred (J)μDynamic viscosity (N.s/m2)
𝑞Average heat generation (W/m3)ψCircularity
TMean Temperature (°C)νKinematic viscosity m2/s
WWidth of channel, (m) τTransmissivity
wWidth of one set of rib, (m)
VVelocity of working fluid (m/s)Abbreviations
DhHydraulic diameter (m)DPPFDouble-Pass Parallel Flow
SubscriptsTHPPThermohydraulic performance parameter
AAmbient, AirSAHSolar Air Heater
absAbsorber
AmbAmbientmMean
dDuct/ channel, diameteruUseful
gGlass covertThermal
hHeight, holeeffEffective
InsInsulationex.Exergetic

References

  1. Klein, S.A.; Beckman, W.A.; Duffie, J.A. A design procedure for solar air heating systems. Sol. Energy 1977, 19, 509–512. [Google Scholar] [CrossRef]
  2. Saini, M.; Sharma, A.; Singh, V.P.; Jain, S.; Dwivedi, G. Solar Thermal Receivers—A Review. Lect. Notes Mech. Eng. 2022, 2, 311–325. [Google Scholar] [CrossRef]
  3. Alam, T.; Meena, C.S.; Balam, N.B.; Kumar, A.; Cozzolino, R. Thermo-hydraulic performance characteristics and optimization of protrusion rib roughness in solar air heater. Energies 2021, 14, 3159. [Google Scholar] [CrossRef]
  4. Alam, T.; Kim, M.-H. Heat transfer enhancement in solar air heater duct with conical protrusion roughness ribs. Appl. Therm. Eng. 2017, 126, 458–469. [Google Scholar] [CrossRef]
  5. Singh, S. Experimental and numerical investigations of a single and double pass porous serpentine wavy wiremesh packed bed solar air heater. Renew. Energy 2020, 145, 1361–1387. [Google Scholar] [CrossRef]
  6. Ho, C.D.; Hsiao, C.F.; Chang, H.; Tien, Y.E. Investigation of Device Performance for Recycling Double-pass V-corrugated Solar Air Collectors. Energy Procedia 2017, 105, 28–34. [Google Scholar] [CrossRef]
  7. Fudholi, A.; Sopian, K.; Ruslan, M.H. Thermal Efficiency of Double Pass Solar Collector with Longitudinal Fins Absorbers Thermal Efficiency of Double Pass Solar Collector with Longitudinal Fins Absorbers. Am. J. Appl. Sci. 2011, 8, 254–260. [Google Scholar] [CrossRef]
  8. Kumar, A.; Akshayveer; Singh, A.P.; Singh, O.P. Efficient designs of double-pass curved solar air heaters. Renew. Energy 2020, 160, 1105–1118. [Google Scholar] [CrossRef]
  9. Yadav, K.D.; Prasad, R.K. Performance analysis of parallel flow flat plate solar air heater having arc shaped wire roughened absorber plate. Renew. Energy Focus 2020, 32, 23–44. [Google Scholar] [CrossRef]
  10. Hernández, A.L.; Quiñonez, J.E. Analytical models of thermal performance of solar air heaters of double-parallel flow and double-pass counter flow. Renew. Energy 2013, 55, 380–391. [Google Scholar] [CrossRef]
  11. Jain, S.; Gupta, J.; Singh, V.P. Analysis of the effect of perforation in multi-v rib artificial roughened single pass solar air heater:—Part A. Exp. Heat Transf. 2021, 1–20. [Google Scholar] [CrossRef]
  12. Gupta, J.; Singh, V.P.; Jain, S. Performance assessment of double-pass parallel flow solar air heater with perforated multi-V ribs roughness—Part B. Exp. Heat Transf. 2022, 1–18. [Google Scholar] [CrossRef]
  13. Singh, V.P.; Jain, S.; Gupta, J.M.L. Analysis of the effect of variation in open area ratio in perforated multi-V rib roughened single pass solar air heater—Part A. Energy Sources Part A Recover. Util. Environ. Eff. 2022, 1–20. [Google Scholar] [CrossRef]
  14. Singh, V.P.; Jain, S.; Kumar, A. Establishment of correlations for the Thermo-Hydraulic parameters due to perforation in a multi-V rib roughened single pass solar air heater. Exp. Heat Transf. 2022, 1–20. [Google Scholar] [CrossRef]
  15. Karwa, R.; Maheshwari, B.K.K. Heat transfer and friction in an asymmetrically heated rectangular duct with half and fully perforated baffles at different pitches. Int. Commun. Heat Mass Transf. 2009, 36, 264–268. [Google Scholar] [CrossRef]
  16. Kwak, J.S.; Shin, S. Effect of hole shape on the heat transfer in a rectangular duct with perforated blockage walls. J. Mech. Sci. Technol. 2008, 22, 1945–1951. [Google Scholar] [CrossRef]
  17. Alam, T.; Saini, R.P.; Saini, J.S. Effect of circularity of perforation holes in V-shaped blockages on heat transfer and friction characteristics of rectangular solar air heater duct. Energy Convers. Manag. 2014, 86, 952–963. [Google Scholar] [CrossRef]
  18. Bahuguna, R.; Mer, K.K.S.; Kumar, M.; Chamoli, S. Entropy generation analysis in a tube heat exchanger integrated with triple blade vortex generator inserts. Energy Sources Part A Recover. Util. Environ. Eff. 2021, 1–19. [Google Scholar] [CrossRef]
  19. Chamoli, S.; Thakur, N.S. Heat transfer enhancement in solar air heater with V-shaped perforated baffles. J. Renew. Sustain. Energy 2013, 5, 023122. [Google Scholar] [CrossRef]
  20. Tariq, A.; Panigrahi, P.K.; Muralidhar, K. Flow and heat transfer in the wake of a surface-mounted rib with a slit. Exp. Fluids 2004, 37, 701–719. [Google Scholar] [CrossRef]
  21. Duffie, J.A.; Beckman, W.A.; Winston, R.; Kreith, F. Solar Energy Thermal Processes. Phys. Today 1976, 29, 62–67. [Google Scholar] [CrossRef]
  22. Phu, N.M.; Bao, T.T.; Hung, H.N.; Tu, N.T.; van Hap, N. Analytical predictions of exergoeconomic performance of a solar air heater with surface roughness of metal waste. J. Therm. Anal. Calorim. 2020, 144, 1727–1740. [Google Scholar] [CrossRef]
  23. Phu, N.M.; Thao, P.B.; van Hap, N. Effective efficiency assessment of a solar air heater having baffles spaced with different successive ratios. Case Stud. Therm. Eng. 2021, 28, 101486. [Google Scholar] [CrossRef]
  24. Phu, N.M.; van Hap, N. Performance Evaluation of a Solar Air Heater Roughened with Conic-Curve Profile Ribs Based on Efficiencies and Entropy Generation. Arab. J. Sci. Eng. 2020, 45, 9023–9035. [Google Scholar] [CrossRef]
  25. van Hap, N.; Phu, N.M. Heat Transfer in Double-Pass Solar Air Heater: Mathematical Models and Solution Strategy; IntechOpen: London, UK, 2022. [Google Scholar]
  26. Phu, N.M.; Tu, N.T.; van Hap, N. Thermohydraulic performance and entropy generation of a triple-pass solar air heater with three inlets. Energies 2021, 14, 6399. [Google Scholar] [CrossRef]
  27. Kumar, A.; Saini, R.P.P.; Saini, J.S.S. Development of correlations for Nusselt number and friction factor for solar air heater with roughened duct having multi v-shaped with gap rib as arti fi cial roughness. Renew. Energy 2013, 58, 151–163. [Google Scholar] [CrossRef]
  28. Sharma, A.; Bharadwaj, G.; Varun. Heat transfer and friction factor correlation development for double-pass solar air heater having V-shaped ribs as roughness elements. Exp. Heat Transf. 2017, 30, 77–90. [Google Scholar] [CrossRef]
  29. Ravi, R.K.; Saini, R.P. Nusselt number and friction factor correlations for forced convective type counter flow solar air heater having discrete multi V shaped and staggered rib roughness on both sides of the absorber plate. Appl. Therm. Eng. 2018, 129, 735–746. [Google Scholar] [CrossRef]
  30. Patel, S.S.; Lanjewar, A. Exergy based analysis of solar air heater duct with W-shaped rib roughness on the absorber plate. Arch. Thermodyn. 2019, 40, 21–48. [Google Scholar] [CrossRef]
  31. Kumar, B.; Patil, A.K.; Jain, S.; Kumar, M. Effects of Double V Cuts in Perforated Twisted Tape Insert: An Experimental Study. Heat Transf. Eng. 2020, 41, 1473–1484. [Google Scholar] [CrossRef]
  32. Raj, B.P.; Meena, C.S.; Agarwal, N.; Saini, L.; Hussain Khahro, S.; Subramaniam, U.; Ghosh, A. A review on numerical approach to achieve building energy efficiency for energy, economy and environment (3e) benefit. Energies 2021, 14, 4487. [Google Scholar] [CrossRef]
  33. Kumar, R.; Kumar, A.; Goel, V. Performance improvement and development of correlation for friction factor and heat transfer using computational fluid dynamics for ribbed triangular duct solar air heater. Renew. Energy 2019, 131, 788–799. [Google Scholar] [CrossRef]
  34. Gupta, B.; Manikpuri, G.P.; Waiker, J.K.; Pandya, M. Experimental Investigation of Double Pass Solar Air Heater using different type of Porous Media. Int. J. Curr. Eng. Technol. 2013, 3, 2006–2009. [Google Scholar]
  35. Alam, T.; Kim, M.-H. A critical review on artificial roughness provided in rectangular solar air heater duct. Renew. Sustain. Energy Rev. 2017, 69, 387–400. [Google Scholar] [CrossRef]
  36. Meena, C.S.; Raj, B.P.; Saini, L.; Agarwal, N. Performance Optimization of Solar-Assisted Heat Pump System for Water Heating Applications. Energies 2021, 14, 3534. [Google Scholar] [CrossRef]
  37. Klein, S.A.; Duffie, J.A.; Beckman, W.A. Transient considerations of flat-plate solar collectors. J. Eng. Gas Turbines Power 1974, 96, 109–113. [Google Scholar] [CrossRef]
  38. Bliss, R.W. The derivations of several ‘Plate-efficiency factors’ useful in the design of flat-plate solar heat collectors. Sol. Energy 1959, 3, 55–64. [Google Scholar] [CrossRef]
  39. Agarwal, V.K.; Larson, D.C. Calculation of the top loss coefficient of a flat-plate collector. Sol. Energy 1981, 27, 69–71. [Google Scholar] [CrossRef]
  40. Klein, S.A. Calculation of flat-plate collector loss coefficients. Sol. Energy 1975, 17, 79–80. [Google Scholar] [CrossRef]
  41. Beckman, W.; Bugler, J.; Cooper, P.; Duffie, J.; Dunkle, R.; Glaser, P.; Horigome, T.; Howe, E.; Lawand, T.; Van Der Mersch, P.; et al. Units and symbols in solar energy. Sol. Energy 1978, 21, 65–68. [Google Scholar] [CrossRef]
  42. Garg, H.P.; Datta, G. The top loss calculation for flat plate solar collectors. Sol. Energy 1984, 32, 141–143. [Google Scholar] [CrossRef]
  43. Akhtar, N.; Mullick, S.C. Approximate method for computation of glass cover temperature and top heat-loss coefficient of solar collectors with single glazing. Sol. Energy 1999, 66, 349–354. [Google Scholar] [CrossRef]
  44. Mullick, S.C.; Nanda, S.K. An improved technique for computing the heat loss factor of a tubular absorber. Sol. Energy 1989, 42, 1–7. [Google Scholar] [CrossRef]
  45. Kumar, S.; Mullick, S.C. Wind heat transfer coefficient in solar collectors in outdoor conditions. Sol. Energy 2010, 84, 956–963. [Google Scholar] [CrossRef]
  46. Cortes, A.; Piacentini, R. Improvement of the Efficiency of a Bare Solar Collector by Means of Turbulence Promoters. Appl. Energy 2000, 36, 253–261. [Google Scholar] [CrossRef]
  47. Shetty, S.P.; Paineni, A.; Kande, M.; Madhwesh, N.; Sharma, N.Y.; Karanth, K.V. Experimental investigations on a cross flow solar air heater having perforated circular absorber plate for thermal performance augmentation. Sol. Energy 2020, 197, 254–265. [Google Scholar] [CrossRef]
  48. Altfeld, K. Second law optimization of flat-plate solar air heaters Part I: The concept of net exergy flow and the modeling of solar air heaters. Sol. Energy 1988, 41, 127–132. [Google Scholar] [CrossRef]
Figure 1. (a) Schematic view of parallel flow SAH with perforated multi-V rib roughness and (b) Cross-sectional view of the DPPFSAH duct.
Figure 1. (a) Schematic view of parallel flow SAH with perforated multi-V rib roughness and (b) Cross-sectional view of the DPPFSAH duct.
Sustainability 14 10535 g001
Figure 2. Thermal resistance circuit of the DPPFSAH.
Figure 2. Thermal resistance circuit of the DPPFSAH.
Sustainability 14 10535 g002
Figure 3. Flow diagram for the computer program to calculate the thermal efficiency of SPSAH and DPPFSAH.
Figure 3. Flow diagram for the computer program to calculate the thermal efficiency of SPSAH and DPPFSAH.
Sustainability 14 10535 g003
Figure 4. (a) ηth vs. Re and (b) ηth vs. ΔT/I as a function of selected values of parameters of smooth and roughened SPSAHs and DPPFSAHs.
Figure 4. (a) ηth vs. Re and (b) ηth vs. ΔT/I as a function of selected values of parameters of smooth and roughened SPSAHs and DPPFSAHs.
Sustainability 14 10535 g004
Figure 5. ηth vs. ΔT/I for various W/w values in (a) SPSAH and (b) DPPFSAH.
Figure 5. ηth vs. ΔT/I for various W/w values in (a) SPSAH and (b) DPPFSAH.
Sustainability 14 10535 g005
Figure 6. ηth vs. ΔT/I for various β values in (a) SPSAH and (b) DPPFSAH.
Figure 6. ηth vs. ΔT/I for various β values in (a) SPSAH and (b) DPPFSAH.
Sustainability 14 10535 g006
Figure 7. Effect of variation in (a) W/w and (b) β on EEF as a function of ΔT/I for DPPFSA.
Figure 7. Effect of variation in (a) W/w and (b) β on EEF as a function of ΔT/I for DPPFSA.
Sustainability 14 10535 g007
Figure 8. EEF vs. ΔT/I at different I values for DPPFSAH.
Figure 8. EEF vs. ΔT/I at different I values for DPPFSAH.
Sustainability 14 10535 g008
Figure 9. Influence of W/w on ηeff as a function of (a) W/w and (b) Re values for DPPFSAH.
Figure 9. Influence of W/w on ηeff as a function of (a) W/w and (b) Re values for DPPFSAH.
Sustainability 14 10535 g009
Figure 10. Influence of β on ηeff as a function of (a) ΔT/I and (b) Re for DPPFSAH.
Figure 10. Influence of β on ηeff as a function of (a) ΔT/I and (b) Re for DPPFSAH.
Sustainability 14 10535 g010
Figure 11. Optimum values of (a) W/w and (b) β for DPPFSAH.
Figure 11. Optimum values of (a) W/w and (b) β for DPPFSAH.
Sustainability 14 10535 g011
Figure 12. (a) ηexg vs. ΔT/I and (b) ηexg vs. Re graph for various W/w values for DPPFSAH.
Figure 12. (a) ηexg vs. ΔT/I and (b) ηexg vs. Re graph for various W/w values for DPPFSAH.
Sustainability 14 10535 g012
Figure 13. (a) ηexg vs. ΔT/I and (b) ηexg vs. Re relation for various β for DPPFSAH.
Figure 13. (a) ηexg vs. ΔT/I and (b) ηexg vs. Re relation for various β for DPPFSAH.
Sustainability 14 10535 g013
Figure 14. Optimum values of (a) W/w and (b) β for ηexg for DPPFSAH.
Figure 14. Optimum values of (a) W/w and (b) β for ηexg for DPPFSAH.
Sustainability 14 10535 g014
Figure 15. Comparison of optimum values of (a) W/w and (b) β for DPPFSAH.
Figure 15. Comparison of optimum values of (a) W/w and (b) β for DPPFSAH.
Sustainability 14 10535 g015
Table 1. Values of fixed parameters considered for the DPPFSAH.
Table 1. Values of fixed parameters considered for the DPPFSAH.
S. No.ParameterValue/Range
1.No. of PassTwo (DPPF)
2.Type of FlowParallel Flow
3.L1.0 m
4.W0.3 m
5.H0.025 m
6.N1 nos.
7.kins0.037 W/m-K
8.tins0.05 m
9.ρ1.105 kg/m3
10.µ1.865 × 10−5 kg/s-m
11.k0.02624 W/m-K
12.τα0.8
12.Hg0.025 m
13.β0 for horizontal
14.𝜀𝑃0.92
15.εg0.88
16.tg0.004 m
17.Ta300 K
18.V1.0 m/s
Table 2. Variable parameters with operational range for DPPFSAH.
Table 2. Variable parameters with operational range for DPPFSAH.
Sr. No.Parameters NotationsRange
1.W/w2–10 (five values)
2.β0.0, 0.21, 0.27, 0.31 (four values)
3.Re2000–18,000 (Nine Values)
4.ΔT/I0.002–0.02 Km2/W (Ten Values)
5.I600–1000 W/m2 (Three values)
Table 3. Values of β and range of ΔT/I for highest ηeff for different combination of DPPFSAH.
Table 3. Values of β and range of ΔT/I for highest ηeff for different combination of DPPFSAH.
Geometric ParameterΔT/I (Km2/W)β
β0.00359 < ΔT/I < 0.007940.21
0.01091 < ΔT/I0.27
0.00794 < ΔT/I < 0.010910.31
ΔT/I < 0.00359Smooth
Geometric ParameterReβ
βRe < 56440.21
5860 < Re < 18,8210.27
5557 < Re < 85270.31
18,821 < ReSmooth
Table 4. Values of ΔT/I for W/w and Re for highest ηeff for different combinations in DPPFSAH.
Table 4. Values of ΔT/I for W/w and Re for highest ηeff for different combinations in DPPFSAH.
Geometric ParameterΔT/I (Km2/W)W/w
W/w0.00835 < ΔT/I < 0.0112610
0.00815 < ΔT/I < 0.011288
0.01128 < ΔT/I6
0.00823 < ΔT/I < 0.011174
0.00371 < ΔT/I < 0.011282
ΔT/I < 0.00371Smooth
Geometric ParameterReW/w
W/wRe < 723910
8527 < Re < 87418
11,881 < Re < 19,0256
7239 < Re < 85274
5644 < Re < 85272
19,025 < ReSmooth
Table 5. Range of ΔT/I and optimum W/w and β values based on ηeff criterion.
Table 5. Range of ΔT/I and optimum W/w and β values based on ηeff criterion.
Geometric ParametersΔT/I (Km2/W)W/w (Optimum)
W/wΔT/I < 0.0095722
0.009572 < ΔT/I < 0.01058Function of ΔT/I of I
0.01058 < ΔT/I6
Geometric ParametersΔT/I (Km2/W)β (Optimum)
βΔT/I < 0.007940.21
0.00794 < ΔT/I < 0.01091Function of ΔT/I of I
0.01091 < ΔT/I0.27
Table 6. Range of ΔT/I and Re for different W/w corresponding to highest ηexg range for different combinations of DPPFSAH.
Table 6. Range of ΔT/I and Re for different W/w corresponding to highest ηexg range for different combinations of DPPFSAH.
Geometric ParameterΔT/I (Km2/W)W/w
W/w0.05021 < ΔT/I < 0.0613410
0.049893 < ΔT/I < 0.061348
0.015298 < ΔT/I6
0.04989 < ΔT/I < 0.061174
0. 0.0059 < ΔT/I < 0.008712
ΔT/I < 0.006985Smooth
Geometric ParameterReW/w
W/w605 < Re < 107510
634 < Re < 11048
Re < 36856
783 < Re < 11754
6207 < Re < 83712
9228 < ReSmooth
Table 7. Range of ΔT/I and Re for different β corresponding to the highest ηexg range for different combinations in DPPFSAH.
Table 7. Range of ΔT/I and Re for different β corresponding to the highest ηexg range for different combinations in DPPFSAH.
Geometric ParameterΔT/I, Km2/Wβ
β0.00919 < ΔT/I < 0.012790.21
0.0169 < ΔT/I0.27
0.04055 < ΔT/I < 0.052710.31
ΔT/I < 0.00359Smooth
Geometric ParameterReβ
β6182 < Re < 79300.21
Re < 40520.27
588 < Re < 9370.31
8503 < ReSmooth
Table 8. Range of ΔT/I for optimum values of W/w and β based on ηexg criterion for DPPFSAH.
Table 8. Range of ΔT/I for optimum values of W/w and β based on ηexg criterion for DPPFSAH.
Rib Roughness
Parameter
ΔT/I
(Km2/W)
W/w
(Optimum Value)
W/wΔT/I < 0.0060512
0.006051 < ΔT/I < 0.008084Function of ΔT/I of I
0.008084 <ΔT/I6
Rib Roughness
Parameter
ΔT/I (Km2/W)β (Optimum Value)
βΔT/I < 0.008270.21
0.00827 < ΔT/I < 0.0169Function of ΔT/I of I
0.0169 < ΔT/I0.27
Table 9. ΔT/I range for optimum roughness parameters as determined by the ηeff and ηexg criteria for I = 1000 W/m2.
Table 9. ΔT/I range for optimum roughness parameters as determined by the ηeff and ηexg criteria for I = 1000 W/m2.
Rib Roughness
Parameter
ΔT/I (Km2/W)Rib Roughness Parameter (Optimum Value)
W/wΔT/I < 0.0060512
ΔT/I > 0.011286
βΔT/I < 0.007940.21
ΔT/I > 0.016930.27
Table 10. For varied I in DPPFSAH, the range of ΔT/I for optimum roughness parameter values are different to ηeff and ηexg requirements.
Table 10. For varied I in DPPFSAH, the range of ΔT/I for optimum roughness parameter values are different to ηeff and ηexg requirements.
Insolation (W/m2)Roughness ParameterRange of ΔT/I
1000W/w0.006051 < ΔT/I < 0.008084
β0.0079413 < ΔT/I < 0.010914
800W/w0.006719 < ΔT/I < 0.008799
β0.008753 < ΔT/I < 0.012713
600W/w0.007528 < ΔT/I < 0.010399
β0.009325 < ΔT/I < 0.014937
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Singh, V.P.; Jain, S.; Karn, A.; Kumar, A.; Dwivedi, G.; Meena, C.S.; Cozzolino, R. Mathematical Modeling of Efficiency Evaluation of Double-Pass Parallel Flow Solar Air Heater. Sustainability 2022, 14, 10535. https://0-doi-org.brum.beds.ac.uk/10.3390/su141710535

AMA Style

Singh VP, Jain S, Karn A, Kumar A, Dwivedi G, Meena CS, Cozzolino R. Mathematical Modeling of Efficiency Evaluation of Double-Pass Parallel Flow Solar Air Heater. Sustainability. 2022; 14(17):10535. https://0-doi-org.brum.beds.ac.uk/10.3390/su141710535

Chicago/Turabian Style

Singh, Varun Pratap, Siddharth Jain, Ashish Karn, Ashwani Kumar, Gaurav Dwivedi, Chandan Swaroop Meena, and Raffaello Cozzolino. 2022. "Mathematical Modeling of Efficiency Evaluation of Double-Pass Parallel Flow Solar Air Heater" Sustainability 14, no. 17: 10535. https://0-doi-org.brum.beds.ac.uk/10.3390/su141710535

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics