Next Article in Journal
4D-CT Attenuation Correction in Respiratory-Gated PET for Hypoxia Imaging: Is It Really Beneficial?
Previous Article in Journal
Radiomics Prediction of EGFR Status in Lung Cancer—Our Experience in Using Multiple Feature Extractors and The Cancer Imaging Archive Data
 
 
Tomography is published by MDPI from Volume 7 Issue 1 (2021). Previous articles were published by another publisher in Open Access under a CC-BY (or CC-BY-NC-ND) licence, and they are hosted by MDPI on mdpi.com as a courtesy and upon agreement with Grapho, LLC.
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Diffusion-Weighted Echo Planar Imaging Using Multiplexed Sensitivity Encoding and Reverse Polarity Gradient in Head Andneck Cancer: An Initial Study

by
Amaresha Shridhar Konar
1,
Maggie Fung
2,
Ramesh Paudyal
1,
Jung Hun Oh
1,
Yousef Mazaheri
1,3,
Vaios Hatzoglou
3 and
Amita Shukla-Dave
1,3,*
1
Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
2
GE Healthcare, New York, NY, USA
3
Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, USA
*
Author to whom correspondence should be addressed.
Submission received: 3 March 2020 / Revised: 7 April 2020 / Accepted: 11 May 2020 / Published: 1 June 2020

Abstract

We aimed to compare the geometric distortion (GD) correction performance and apparent diffusion coefficient (ADC) measurements of single-shot diffusion-weighted echo-planar imaging (SS-DWEPI), multiplexed sensitivity encoding (MUSE)-DWEPI, and MUSE-DWEPI with reverse-polarity gradient (RPG) in phantoms and patients. We performed phantom studies at 3T magnetic resonance imaging (MRI) using the American College of Radiology phantom and Quantitative Imaging Biomarker Alliance DW-MRI ice-water phantom to assess GD and effect of distortion in the measurement of ADC, respectively. Institutional review board approved the prospective clinical component of this study. DW-MRI data were obtained from 11 patients with head and neck cancer using these three DW-MRI methods. Wilcoxon signed-rank (WSR) and Kruskal–Wallis (KW) tests were used to compare ADC values, and qualitative rating by radiologist between three DW-MRI methods. In the ACR phantom, GD of 0.17% was observed for the b = 0 s/mm2 image of the MUSE-DWEPI with RPG method compared with that of 1.53% and 2.1% of MUSE-DWEPI and SS-DWEPI, respectively; The corresponding methods root-mean-square errors were 0.58, 3.37, and 5.07 mm. WSR and KW tests showed no significant difference in the ADC measurement between these three DW-MRI methods for both healthy masseter muscles and neoplasms (P > .05). We observed improvement in spatial accuracy for MUSE-DWEPI with RPG in the head and neck region with a higher correlation (R2 = 0.791) compared with that for SS-DWEPI (R2 = 0.707) and MUSE-DWEPI (R2 = 0.745). MUSE-DWEPI with RPG significantly reduces the distortion compared with MUSE-DWEPI or conventional SS-DWEPI techniques, and the ADC values were similar.
Keywords: head and neck region; diffusion-weighted MRI; echo planar imaging; eddy current; magnetic field inhomogeneity; geometrical distortion; multiplexed sensitivity encoding; reverse-polarity gradients head and neck region; diffusion-weighted MRI; echo planar imaging; eddy current; magnetic field inhomogeneity; geometrical distortion; multiplexed sensitivity encoding; reverse-polarity gradients

Share and Cite

MDPI and ACS Style

Konar, A.S.; Fung, M.; Paudyal, R.; Oh, J.H.; Mazaheri, Y.; Hatzoglou, V.; Shukla-Dave, A. Diffusion-Weighted Echo Planar Imaging Using Multiplexed Sensitivity Encoding and Reverse Polarity Gradient in Head Andneck Cancer: An Initial Study. Tomography 2020, 6, 231-240. https://0-doi-org.brum.beds.ac.uk/10.18383/j.tom.2020.00014

AMA Style

Konar AS, Fung M, Paudyal R, Oh JH, Mazaheri Y, Hatzoglou V, Shukla-Dave A. Diffusion-Weighted Echo Planar Imaging Using Multiplexed Sensitivity Encoding and Reverse Polarity Gradient in Head Andneck Cancer: An Initial Study. Tomography. 2020; 6(2):231-240. https://0-doi-org.brum.beds.ac.uk/10.18383/j.tom.2020.00014

Chicago/Turabian Style

Konar, Amaresha Shridhar, Maggie Fung, Ramesh Paudyal, Jung Hun Oh, Yousef Mazaheri, Vaios Hatzoglou, and Amita Shukla-Dave. 2020. "Diffusion-Weighted Echo Planar Imaging Using Multiplexed Sensitivity Encoding and Reverse Polarity Gradient in Head Andneck Cancer: An Initial Study" Tomography 6, no. 2: 231-240. https://0-doi-org.brum.beds.ac.uk/10.18383/j.tom.2020.00014

Article Metrics

Back to TopTop