Next Article in Journal
DSTEELNet: A Real-Time Parallel Dilated CNN with Atrous Spatial Pyramid Pooling for Detecting and Classifying Defects in Surface Steel Strips
Previous Article in Journal
Continuous and Secure Integration Framework for Smart Contracts
Previous Article in Special Issue
Ion-Imprinted Chitosan-Based Localized Surface Plasmon Resonance Sensor for Ni2+ Detection
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Review

Long-Period Fiber Grating Sensors for Chemical and Biomedical Applications

Wuhan National Laboratory for Optoelectronics & School of Optical and Electronic Information, Huazhong University of Science and Technology, Wuhan 430074, China
*
Author to whom correspondence should be addressed.
Submission received: 7 November 2022 / Revised: 2 December 2022 / Accepted: 4 December 2022 / Published: 3 January 2023
(This article belongs to the Special Issue Optical Fiber Sensors for Chemical and Biomedical Applications)

Abstract

:
Optical fiber biosensors (OFBS) are being increasingly proposed due to their intrinsic advantages over conventional sensors, including their compactness, potential remote control and immunity to electromagnetic interference. This review systematically introduces the advances of OFBS based on long-period fiber gratings (LPFGs) for chemical and biomedical applications from the perspective of design and functionalization. The sensitivity of such a sensor can be enhanced by designing the device working at or near the dispersion turning point, or working around the mode transition, or their combination. In addition, several common functionalization methods are summarized in detail, such as the covalent immobilization of 3-aminopropyltriethoxysilane (APTES) silanization and graphene oxide (GO) functionalization, and the noncovalent immobilization of the layer-by-layer assembly method. Moreover, reflective LPFG-based sensors with different configurations have also been introduced. This work aims to provide a comprehensive understanding of LPFG-based biosensors and to suggest some future directions for exploration.

1. Introduction

Biosensors play a crucial role in environmental and human health monitoring through the efficient and accurate detection of chemistry and biomass. A biosensor normally contains two main components: a bioreceptor and a transducer [1]. When designing a biosensor, it is a key technological step to select the sensitive material suitable for the biological target. Taking the properties of the resulting compounds into account, it is another important step to select the transducer according to the chemical or physical changes caused by the molecular interaction between the biological target and the bioreceptor. The production or consumption of light, heat and chemical substances in the process of recognition is converted into measurable signals [2]. According to these mechanisms, the appropriate transducer can be selected. The information generated by recognition processes is diverse; therefore, the sensors based on electrochemistry, thermotics and optics have been extensively studied.
Optical sensors, especially those based on optical fibers, are being increasingly proposed in the chemical and biomedical applications due to their intrinsic advantages over conventional sensors. Optical fiber biosensors (OFBS) are usually compact and small in size [3] and thus can work with minimal sample volumes. Moreover, OFBS are capable of multiplexing, immune to electromagnetic interference [4] and remote-controllable. The number of publications on OFBS has also steadily increased over the last two decades (as shown in Figure 1). The typical working principle of OFBS is based on monitoring the change of the surrounding refractive index (SRI), produced from the biological target binding on the surface of the fiber, which leads to the alteration of the detectable spectrum [5]. In order to enhance their sensitivity to the SRI, the OFBS are usually machined into microstructures and geometrically modified to generate a strong evanescent field in the sensing area. Examples of such devices include U-shaped and tapered optical fibers [6,7,8,9,10], D-shaped optical fibers [11,12], etched or tilted fiber Bragg gratings (FBGs) [13,14,15], long-period fiber gratings (LPFGs) [16,17,18,19,20], lossy mode resonances (LMRs) [21,22], surface plasmon resonance (SPR) [23,24] Mach–Zehnder interferometers (MZIs) [25,26], photonic-crystal fiber (PCF) [27,28] and Lab-on-Fiber devices [29,30,31]. Among these, some geometrically modified fibers must completely or partially remove the cladding, which affects the robustness of optical fibers, which is a property that should be considered in practical applications. Fortunately, an ideal alternative to avoid this damaging operation is refractive index modulation inside the optical fiber; the grating-based fiber maintains a robust structure and high sensitivity, especially LPFGs, which have been widely used in refractive index sensing, including biochemical molecule sensing [32,33], gas sensing [34,35,36] and ion sensing [37,38].
In this review, we focused attention on LPFG-based sensors for chemical and biomedical applications from the perspective of design and functionalization. Firstly, the principle of LPFG-based biosensors is systematically introduced. Then, several methods to improve the sensitivity of such a sensor are summarized and their applications in the field of biochemistry are illustrated. Furthermore, we categorically describe the biosensing applications of such a sensor in detail according to several typical functionalization methods. Finally, we summarize this review and suggest some future directions for exploration.

2. Principle of LPFG-Based Biosensors

An LPFG is a periodic modulation (usually with period Λ = 100–1000 µm) of RI in the fiber core, as shown in Figure 2; the modulation can couple light from the fundamental core mode (LP01 mode) to forward-propagating cladding modes (LP0 m modes, where m = 2, 3, 4, …) and, therefore, produces a set of resonant attenuation bands centered at discrete wavelengths in the LPFG transmission spectrum [18]. Additionally, the phase-matching condition between the effective propagation constants of the LP01 mode and LP0 m modes can be expressed by [39]:
β 01 β c l m = 2 π Λ
where β 01 and β c l m are the propagation constants for the LP01 mode and LP0 m modes, respectively. Λ is the grating period. For the effective RI (neff) of the LP01 mode and LP0 m modes, they can be expressed by n e f f , c o = β 01 λ 2 π and n e f f , c l a d m = β c l m λ 2 π , respectively. In this case, the resonant wavelengths (λres) are determined by the effective RI of the LP01 mode and LP0 m modes, and we can obtain the following expression [40]:
λ r e s = n e f f , c o n e f f , c l a d m   Λ
For a specific LPFG, Λ can be a constant and n e f f , c o is determined by the RI of the core and cladding, whereas n e f f , c l a d m depends on the difference between the cladding RI and SRI of the cladding. Therefore, the resonance characteristic is affected by the effective RI of the cladding region, which is the basic principle of biological detection. In this way, a shift in the resonance wavelength can be represented by the SRI changes caused by molecular interaction occurring on the fiber surface. Naturally, an LPFG-based biosensor can be achieved by equipping the sensor with chemically responsive coatings to selectively detect the biological targets.

3. RI Sensitivity Enhancement of LPFG-Based Biosensor

For designing an LPFG-based biosensor, the most important work should be focused on how to enhance the sensitivity of such a sensor. Moreover, a detailed investigation shows that the best performance of sensors based on RI sensitivity can be achieved when the SRI is close to the cladding RI (i.e., 1.44–1.46 RIU) [41]. It may be noted that most biosensors are designed to work in aqueous solutions (i.e., 1.33–1.34 RIU), which is very different from the RI of the fiber cladding, resulting in the device exhibiting low sensitivity to aqueous samples. To address this challenge, several approaches have been proposed over these years. The performance of these methods for LPFG-based biosensors is summarized in Table 1.

3.1. Dispersion Turning Point

The most popular methodology is to design a period and cladding mode at or near the dispersion turning point (DTP) according its phase-matching curve (PMC), thereby coupling the forward-propagating core mode with a high-order cladding mode [62]. As shown in Figure 3, the relationship between the grating period and resonance wavelength is demonstrated by the PMC, and the DTP can be observed in the PMC for each cladding mode, where the slope for the higher-order mode changes from positive to negative as the wavelength increases. Hence, for a given grating period, two resonant wavelengths on either side of the DTP are coupled to one cladding mode, forming dual-peak resonances. The spectral difference between the dual peaks can be as the measuring parameter, due to its wavelength changing with the response of LPFGs to the SRI change. In our previous work [18], we theoretically verified that the maximum sensitivity of LPFGs to SRI can be obtained at or near the DTP.
LPFG-based sensors designed near their DTP have been widely used in the field of biochemical sensing throughout the years, due to their high sensitivity to aqueous samples. However, it may be noted that the LPFG based on a DTP sensor with a broad band splits into dual-peak resonances when the device is immersed in the surrounding environment with an RI higher than air (i.e., water). In this case, the device may have a low sensitivity factor, for the reason that the resonant wavelength is far from the DTP. To alleviate this problem, the group of P. Biswas has theoretically and experimentally proved that the sensitivity can be enhanced by tailoring the initial coupling strength of the cladding mode to a specific higher-order cladding mode at the DTP [63].
F. Chiavaioli et al. reported an LPFG-based biosensor near its DTP, with a grating period of 165 μm, for the detection of anti-IgG [42]. Figure 4a shows the simulation result of the dependence between the PMC for the LP0,12 cladding mode and the fiber cladding diameter. The solid black line corresponds to the non-etched fiber; the cladding diameter was etched by the 1% hydrofluoric acid solution. Figure 4b shows the spectral evolution of an LPFG with two resonance bands during the etching process. The transmission spectra of the LPFG with two resonance bands could be obtained before the etching process (dclad = 125 µm) and during the etching with closer bands (dclad = 124.6 µm and 124.2 µm). Further reducing the cladding diameter to 123.8 µm, the dual resonance bands were converted into a single, broader resonance band (i.e., up to the DTP). It then vanished if the cladding diameter was continually reduced. In the evaluation of biosensor performance, the Eudragit L100 copolymer was adopted as the chemically modified layer to provide free carboxyl functional groups to immobilize IgG. The obtained LPFG-based sensor was carried out in human serum, where the detection of anti-IgG concentrations as low as 70 μg/L (460 pM) was measured.
Other than tuning the LPFG to a specific higher-order cladding mode at the DTP by reducing the cladding diameter, the modulation of functional layer thickness has also been adopted. The group of Korposh [43] proposed an LPFG-based biosensor using biotin as a bioreceptor for streptavidin (SV) detection. As shown in Figure 5, the silica core–gold shell nanoparticles (SiO2:Au NPs) were coated onto fibers using the layer-by-layer method with the aid of a poly (allylamine hydrochloride) (PAH) polycation layer. It was convenient to tune the LPFG-based biosensor operating at the DTP using the layer-by-layer deposition method. The diameter of SiO2 NPs was also controlled to study the effect on sensitivity, and the result indicates that larger SiO2 NPs (i.e., 300 nm) exhibited higher sensitivity. It could contribute to the more efficient evanescent wave in 300 nm diameter SiO2 NPs. Furthermore, the larger SiO2 NPs were more conducive to biotin depositing, thus enhancing the ability of adsorption of SV. Finally, they achieved the detection of SV with the lowest measured concentration of 2.5 nM, and this proposed sensor could be applied to targeting clinically relevant protein compounds, only needing to replace the ligand.
On the other hand, it has been proved that a lower-order cladding mode can occur near the DTP by reducing the cladding diameter, and then a more sensitive ability is obtained because of the enhancement of the evanescent field [44]. Enlightened by this, recently, there is an interesting proposal to design a lowest-order cladding mode (LP0,2 cladding mode) of an LPFG near the DTP, to obtain a high-sensitivity device [47]. An LPFG near the DTP was fabricated, followed by etching the cladding diameter up to 20 μm, until the appearance of the LP0,2 mode near the DTP. The proposed device was integrated in a closed flow cell within an SRI range of 1.333 to 1.3335 RIU for testing, leading to a sensitivity of 8751 nm/SRIU. Although it exhibited an excellent performance as a refractometer, many relevant factors should be considered in actual biosensing. On the basis of the foregoing, the same group developed the above device by using the IgG/anti-IgG as a bioconjugate pair for a biosensing application, achieving a limit of detection (LOD) of 0.16 ng/mL (1.06 pM) [48]. In a word, LPFG-based sensors designed at or near their DTP have been widely used in the detection of immunoglobulin [42,46,64], bacteria [16,45,65,66], DNA [67,68,69] and other targets [70,71,72,73,74].

3.2. Mode Transition Effect

As mentioned in the introduction, biochemical sensing is realized by sensing the SRI changes when the bioreceptor layers deposited onto the grating region interact with the target. This principle is essentially due to the fact that a small portion of the cladding mode field, the evanescent field, propagates to the outside of the fiber and interacts with the external environment, resulting in n e f f , c l a d m changes, which depend on the thickness of the interaction region and the penetration depth of the evanescent field [75].
The mode transition (MT) effect has been proposed to optimize the sensitivity of LPFG-based sensors to SRI changes. It can occur by coating the fiber cladding surface with a proper thickness of high RI (HRI) materials. Del Villar et al. have made a comprehensive theory and numerical method in their literature [76]. It demonstrated that HRI coatings could modify one of the cladding modes, resulting in the transition between the lower-order cladding-guided modes (i.e., with a higher effective refractive index) to coating-guided modes, and, henceforward, changes the values of n e f f , c l a d m , which could be exploited to enhance the sensitivity of sensors. The same year, Andrea Cusano et al. experimentally confirmed a redistribution of cladding modes by uniformly depositing nanoscale HRI coatings along the LPFG and their effect on RI sensitivity [77].
Enlightened by this, Yang et al. [49] fabricated an LPFG-based methane sensor, working in MT with HRI overlay deposition of polycarbonate (PC)/cryptophane A. They used an automatic dip-coating technique to tune the working point of the sensor in the MT region (bulk RI sensitivity was 3.56 × 103 nm/RIU). The detection of methane was performed with a high sensitivity of 2.5 nm/% and LOD of 0.2 % (v/v). The group of Esposito reported a single-ended LPFG-based sensor for the detection of butane gas, modified with a nanosized HRI overlay of atactic polystyrene [50]. By means of optimizing the layer thickness range, the working point of the device could be tuned within the MT region. The detection of butane vapor was performed with concentrations up to 1.0 vol%, resulting in 2.2 nm/vol% sensitivity, and having the ability to detect concentrations as low as one-tenth of butane lower than the explosive limit. The same research group also fabricated a multilayer-structure LPFG-based sensor; the structure diagram is shown in Figure 6a [51]. The layer consists of PC film and a much thinner layer of graphene oxide (GO), where the nanosized thickness of the PC film was flexibly controlled using the dip-coating technique, in favor of tuning the device to work in the MT region. Figure 6b shows the wavelength shift of the attenuation band as a function of PC thickness, operating air and PBS solution as surroundings. The second layer of GO was exploited due to its properties of biocompatibility and abundant functional groups, which gave the device the ability to bond biometric molecules; then, the high-affinity streptavidin–biotin system was chosen to evaluate the performance of the device through the detection of biotinylated BSA, achieving a LOD of 0.2 aM.
In addition to using HRI organic materials as coatings, many inorganic materials have also been selected to tune the working point in the MT region. The main advantages of inorganic coating materials are that there is a greater available range of RI values and more growth techniques and that it is easier to obtain uniform thickness compared to organic materials. Piestrzyńska et al. reported a label-free biosensor based on LPFGs, deposited with a thin tantalum oxide (TaOx) overlay for RI sensitivity. Since the RI of TaOx was as high as 2 in the IR spectral range, the thickness of overlay was precisely controlled at subnanometer, using atomic layer deposition technique. The RI sensitivity of obtained LPFG-based sensors was 11,500 nm/RIU in the RI range of 1.335 to 1.345 RIU [52]. Continually, the group of Saha theoretically studied the phenomenon of cladding MT by coating with an HRI layer of Si3N4; the result showed that the RI sensitivity was more than 100 μm/RIU for aqueous solution (i.e., RI= 1.33) [53]. Another recent contribution from the group of Li., who used an LPFG-based sensor coated with Au-Si thin films for RI sensing, was the achievement of an ultrahigh 7267.7 nm/RIU sensitivity (i.e., around RI= 1.315); they attributed this excellent performance to the MT of the EH cladding modes and a strong evanescent field penetrating the surroundings [54].
Although various types of coating materials have been exploited, ranging from organic to inorganic, they still have a negative effect on the obtained device, including its repeatability and long-term stability and absorption loss [55]. Therefore, a new strategy has been employed through using double-cladding fiber (DCF) with a W-shaped RI profile. The group of Esposito realized the MT effect for RI sensitivity by writing the LPFG fabricated in a W-shaped DCF for the first time. The outer cladding RI of the DCF was higher than the inner cladding one; hence, the outer cladding of the DCF acted similarly to the HRI overlay. In order to tune the working point to the MT region of this advice, the outer cladding was etched by a chemical reagent. Finally, attention was focused on the SRI sensitivity, achieving a 420 nm/RIU sensitivity in water-like surroundings, which confirmed that these device could be used for biochemical sensing without an HRI coating [55]. Subsequently, they developed and tested this special structure device, through coating with a nanoscale GO layer to offer functional groups to covalently bond the antibody. A working range from 1 ng/mL to 100 μg/mL and a LOD of 0.15 ng/mL were achieved for the detection of C-reactive protein in serum [56]. Recently, the same group reported a similar DCF biosensor for the detection of vitamin D. As shown in Figure 7, the nanometric GO was also selected to provide carboxylic functional groups for the covalent immobilization of Anti-VitD3. The selective detection with a range of 1–1000 ng/mL in buffer solution was obtained, and these devices also performed well in a complex medium with interfering proteins [57].

3.3. The Combination of These Approaches

As mentioned above, the LPFG working at or near the DTP offers a high SRI sensitivity, but the maximum sensitivity is limited to the vicinity of the DTP, indicating that it is difficult for LPFG-based device to maintain the maximum sensitivity in a broad RI range [59]. When the LPFG devices are applied to biochemical sensing, it faces a varying RI range. For example, for the conventional bioreceptor (e.g., protein, DNA, antibody) to detect a biotarget (e.g., protein, antigen), the SRI varies from 1.333 to 1.353 RIU [12,45]. However, for the LPFG modified with gelatin as a humidity sensor, the SRI varies from 1.3408 RIU to the RI of the cladding [78].
Similarly, the MT effect can guide one of the cladding modes to coating-guided modes, and a specified sensitivity range can be tuned by the precise adjustment of the thickness and reducing the cladding diameter [59,61]. It indicates that the combination of both the DTP and MT effect can improve LPFGs’ sensing properties, including the high sensitivity and the specified SRI working range. For example, the group of Mateusz realized an RI sensitivity of 2000 nm/RIU in a broader RI range (1.34–1.356 RIU) [59]. In this work, the cladding diameter and coating thickness were controlled in a nanometer range to reach both the DTP and MT effects, using the method of reactive ion etching (RIE) and radio frequency plasma-enhanced chemical vapor deposition. In addition, many reported works demonstrated that the sensitivity could also be improved by reducing the diameter of the LPFG-based sensor [42,79]. Enlightened by this, the cladding diameter was combined with the DTP and the MT effect for optimizing the sensitivity to the SRI by Del Villar in [60]. A numerical method based on the exact calculation of the core and cladding modes and coupled mode theory was used to analyze the optimization of an LPFG based on the above three factors. Eventually, a considerable sensitivity of 143 × 103 nm/RIU was obtained, which was expected to improve the resolution of the LPFG-based chemical and biological sensors. Recently, Fang et al. also adequately combined both the DTP and MT effects using TiO2 as the high RI nanofilm deposited by atomic layer deposition technology [61]. To keep the spectral difference of the dual peaks constant, the appropriate grating period was selected in different LPFGs, and different TiO2 thicknesses were investigated to optimize the sensitivity in a specific SRI range. As shown in Figure 8, it showed an SRI sensitivity of 10,000 nm/RIU in the range 1.336–1.3397 RIU, 42,000 nm/RIU in the range of 1.4526–1.4561 RIU, 15,000 nm/RIU in the range of 1.392–1.3971 RIU and 23,000 nm/RIU in the range of 1.44–1.4436 RIU. From Figure 8c,d, it indicates that two high-sensitivity ranges could be realized in the same LPFG device.

4. The Functionalization of LPFG-Based Biosensors

It is important to note that the LPFG-based biosensor is applied to measure the wavelength shift caused by the RI change of the device surface due to the selective adsorption for target molecules on the surface, rather than measuring the wavelength shift caused by the change of the RI of the bulk surrounding medium. Therefore, the functionalization of the LPFG-based biosensor is a fundamental step in realizing biochemical applications. Generally, two-part functional layers are deposited onto the surface of the LPFG-based biosensor: one part is the biocarrier layer used as the immobilization of the bioreceptor, and the other is the bioreceptor layer used as the recognition element (enzymes, proteins, antibodies, and so on) to selectively capture the target. Therefore, various methods have been employed for the immobilization of the bioreceptor layer onto the optical fiber. The comparison between the bioreceptor, target and performance of the different functionalization methods of LPFG-based biosensors can be seen in Table 2.

4.1. APTES Silanization

The most effective method for LPFG-based biosensor functionalization is based on covalent immobilization, due to its permanent attachment to the bioreceptor. The 3-aminopropyltriethoxysilane (APTES) silanization is a common and ideal method used in most chemical modifications of silica substrates. This method was successfully realized for the covalent immobilization of protein [101,102], DNA [67,68], antibodies [17,82,103] and so on.
In this case, the optical fiber requires a pretreatment step to form silanol groups (Si-OH), by immersing in KOH/NaOH, acid, or piranha solution. Similarly, ethoxy (–OCH2CH3) groups existing in the APTES molecule can also form the Si-OH through a hydrolysis reaction in aqueous environments [104]. Then, the condensation between Si-OH leads to the formation of a siloxane (Si-O-Si) bond, allowing the APTES molecules to immobilize onto the fiber surface. In addition, the adjacent APTES molecules can form a polymer matrix through condensation, resulting in the formation of free amino-functional (–NH2) surfaces of silica substrates [105]. After the silanization is accomplished, there is a step of activation of thecarboxyl groups on antibodies or enzymes, with the aid of 1-ethyl-3- (3-dimethylaminopropyl) carbodiimide hydrochloride (EDC) and N-hydroxysuccinimimide (NHS). Then, the antibodies or enzymes can be bonded to the –NH2 groups via forming amide bonds, hydrogen bonding, or electrostatic interaction [106].
The group of Anjli proposed an enzymatic biosensor based on LPFG through the stable covalent binding of the lipase enzyme for the detection of triacylglycerides [80]. Figure 9 shows the step of the immobilization of the lipase enzyme; the lipase enzyme was bonded to the fiber surface by forming amide bonds between –NH2 groups on the fiber and –COOH groups of the enzyme. The wavelength shift was measured in association with the enzyme interacting with the target. The detection of triacylglyceride concentrations as low as 17.71 mg/dL was measured; a specific test was also carried out in human blood, and the entire experiment was operated at a constant temperature of 37 °C. APTES silanization to immobilize glucose oxidase was also performed by Wu in [81]. In this work, glucose oxidase was immobilized onto the S-shaped LPFG by APTES silanization technology and used as the bioreceptor for the detection of glucose. The transmission loss variation was used as a measurement associated with glucose oxidase and glucose-specific binding. The experimental results show that the proposed sensor performed a sensitivity of 6.229 dB/wt% in a range from 0∼1 wt%. More recently, Gan et al. [39] developed an LPFG-based sensor based on egg yolk antibody (IgY) covalently immobilized by APTES silanization for the detection of Staphylococcus aureus. The detection test could be completed in about 20 min, and the detection of Staphylococcus aureus was performed down to 33 CFU/mL. Therefore, the developed device for the detection of Staphylococcus aureus was expected to be applied to the field of medical and food detection.

4.2. GO Functionalization

Although the amino functionalized fiber is widely proposed, the single functional group makes it unable to bond to other kinds of biological receptors, thus limiting its application. Different research groups have focused their attention on GO; the fiber surface is chemically or physically deposited with GO nanosheets after silanization. The GO is rich in oxygen-containing functional groups, such as epoxy, hydroxyl and carboxyl, which provide GO the capability to covalently bond various biomolecules [107]. Moreover, the GO is also endowed with the capability to adsorb biomolecules by noncovalent immobilizing, such as electrostatic, interaction hydrogen bonding and π–π stacking [108,109].
Chen et al. [46] reported a dual-peak LPFG deposited with GO nanosheets to immobilize the IgG and the IgG/anti-IgG as a bioconjugate pair for immunosensing. They adopted a new strategy to deposit GO that relied on chemical bonding followed by physical adsorption. Chemical bonding occurred between the APTES-silanized fiber and GO. In the meanwhile, GO nanosheets were physically adsorbed on the fiber surface, along with the evaporation of water. Finally, the GO-deposited LPFG-based sensor was immersed into IgG solution and covalently bonded together via EDC/NHS cross-linking chemistry. The detection of anti-IgG was obtained down to a concentration of 7 ng/mL in PBS buffer. The reusability of the sensor was also carried out by stripping off bound anti-IgG. Successively, the same group developed the detection of hemoglobin, based on a GO nanosheet-functionalized LPFG-based sensor [85]. As shown in Figure 10, the chemical bonding followed by physical adsorption strategy was also adopted for depositing GO, and the sensing principle was based on the measurement of variation in the resonance intensity, caused by noncovalent interaction between the hemoglobin molecules and GO. The desirable GO thickness was controlled to 501.8 nm, which provided a significant light–matter interaction between evanescent field and target molecules. The developed sensor performed with a sensitivity of −77 dB/RIU and a LOD of 0.05 mg/mL for hemoglobin detection.
Recently, the detection limits and deposition method have been further improved by Wang et al. in [86]. In this work, a micro-tapered LPFG was deposited with GO nanosheets for the detection of hemoglobin. After completing the chemical bonding followed by physical adsorption, they took advantage of the optical tweezer effect to further enhance the interaction between GO nanosheets and the fiber. The GO thickness of 203.6 nm was immobilized onto the micro-tapered LPFG. The LOD of 0.02 mg/mL in various interfering compounds was obtained. More recently, the same group developed a biosensor with the same structure for bovine serum albumin (BSA) detection [87]. The sensing mechanism relies on measuring the wavelength shift caused by the covalent bonding between the GO and BSA. The LOD of 0.043 mg/mL, 0.029 mg/mL and 0.032 mg/mL were achieved in DI water, urea and glucose, respectively. Similarly, they also proposed a micro-tapered LPFG functionalized by GO/polydopamine nanocomposites for cobalt ion sensing [88]; the nanocomposites were deposited onto the micro-tapered LPFG surface on account of APTES silanization followed by the optical tweezers effect. The proposed sensor showed a sensitivity of 2.4 × 10−3 dB/ppb in the cobalt ion concentration range from 1 ppb to 107 ppb, and a detection limit of concentrations as low as 0.17 ppb was achieved. The micro-tapered LPFG-based sensors functionalized by GO have also been implemented for Na+ and Mn2+ ion detection in [110] and Ni2+ ion detection in [89].

4.3. Layer-by-Layer Assembly Method

The method of covalent modification of fibers introduced above has good stability; however, it is more complicated to control the thickness, such as controlling the reaction concentration and time. The realization of functional coating with a controllable thickness is also a factor to be considered when optimizing the sensing sensitivity of the LPFG-based device. The layer-by-layer (LbL) assembly provides a promising way to precisely deposit a functional coating with a nanometer-scale thickness [70,111], driven by electrostatic interactions between oppositely charged polyelectrolytes [112,113].
The group of Tian [90] developed a salinity sensor based on LPFG coated with ionic-strength responsiveness of chitosan (CHI)/poly (acrylic acid) (PAA) polyelectrolyte multilayers by the LbL assembly method. The entire deposition process was repeated 20 times by immersion of the device into a polycation CHI and polyanion PAA, respectively. Interestingly, the LPFG resonance wavelength shift changed from red to blue with increasing salt concentration. It could be explained by the de-swelling or swelling of the coating in response to a different range of NaCl concentration. The sensitivity of 36 nm/M was obtained in the range of 0.5–0.8 M. This research was also expected to apply to biomedicine and drug delivery. Similarly, the same group also proposed a salinity sensor which coated with ionic strength-responsive hydrogel onto the LPFG [91]. The two-component polyelectrolytes deposited by LbL assembly might cause some problems, i.e., pH cross-sensitivity and nonlinear relations between the resonance wavelength shift and the concentration of salinity. As shown in Figure 11, this work fabricated a novel sensor coated with a quaternized poly (4-vinylpyridine) (qP4VP) hydrogel via LbL assembly, followed by chemical cross-linking. It is worth noting that the polyanion PAA was selectively released from the coating after chemical cross-linking to obtain a single-component hydrogel. The developed sensor exhibited a sensitivity of 7 nm/M, and there was a good linear relationship between the resonance wavelength shift and salinity concentration in the range of 0.4–0.8 M.
Other polyelectrolyte functional coatings were also deposited onto LPFG-based biosensor by the LbL assembly method. An LPFG-based biosensor coated with nano-assembled thin film of poly (diallyldimethyammonium chloride) (PDDA) and tetrakis (4-sulfophenyl)porphine (TSPP) via the LbL technique for ammonia gas detection was fabricated by Lee et al. [92]. The group of Abd-Rahman fabricated a PDDA/poly (sodium-p-styrenesulfonate) (PSS)-Au nanoparticle coating layer onto an LPFG surface by using the LbL technique for mercury (II) ion sensing [93]. The designed sensor had an excellent performance in the mercury (II) ion concentration range of 0.5 ppm to 10 ppm. Liu et al. [64] developed an LPFG-based biosensor coated with poly (allylamine hydrochloride) (PAH)/gold-coated silica nanoparticles via the LbL method for the detection of streptavidin and immunoglobulin M (IgM). Ni et al. [94] investigated an LPFG-based sensor with a coating of poly (ethylenimine) (PEI) and poly (acrylic acid) (PAA) for pH sensing; the coating layer improved the dispersion and the adhesion ability of multi-walled carbon nanotubes. The group of Tian [95] considered PAH/PAA as a polyelectrolyte functional coating deposited by LbL assembly to bond specific antibodies for the detection of Staphylococcus aureus. The polyelectrolyte functional coating could facilitate the bacterial adhesion, and the detection with a LOD of 224 CFU/mL was demonstrated in PBS.

4.4. Other Methods

The method of optical fiber functionalization depends on the application environment to a certain extent. The functionalization method of optical fibers applied in air is more concise and simpler than those applied in aqueous solution. For example, the dip-coating technique, which is simple to operate and makes it easy to control the thickness of sensitive film, is widely used in gas sensing.
The group of Feng [96] reported the molybdenum sulfide/citric acid composite films that were deposited by using the sol–gel and dip-coating techniques onto an LPFG for measuring trace hydrogen sulfide gas. Figure 12 shows the SEM images of the surface and cross section of the LPFG coated with molybdenum sulfide/citric acid composite films. It can be observed from Figure 12b that the thickness of the film was uniformly controlled at 590 nm. The proposed sensor exhibited a high sensitivity of 10.52 pm/ppm within a hydrogen sulfide gas concentration range from 0 to 70 ppm, and the hydrogen sulfide gas was detected down to a concentration of 0.5 ppm. The same group also studied the tapered LPFG-based sensor functionalized by molybdenum sulfide/citric acid composite films for hydrogen sulfide gas sensing [114]. A sensitivity of 16.65 pm/ppm was achieved. In addition, an LPFG-based sensor coated with GO was developed for nitric oxide (NO) gas detection by the group of Ding [97]. The coatings were prepared by using the dip-coating technique after a 5% HNO3 solution treatment. The NO sensor exhibited excellent sensing features in the NO concentration range of 0 to 400 ppm. Xu et al. proposed an LPFG-based sensor deposited with GO/cellulose acetate composites for ammonia sensing [115]. The chemical cross-linking method and dip-coating technique were taken to deposit these composites. The proposed ammonia sensor exhibited excellent sensitivity (98.32 pm/ppm).
In addition, the metal organic frameworks (MOFs), because of their excellent properties of tunable porosity, large internal surface area and organic functionality, have been widely applied for functionalizing LPFG-based sensors for gas sensing and other sensing. MOFs are hybrid crystalline nanomaterials composed of metal cations and organic ligands [116,117,118]. The methods of functionalizing optical fibers with MOFs mainly focus on in situ crystallization [119,120]. The group of Korposh developed an LPFG-based organic vapor sensor functionalized by zeolitic imidazole framework-8 (ZIF-8) films [121]. As shown in Figure 13a, the ZIF-8 films were deposited onto the LPFG surface using the in situ crystallization technique. The transmission spectrum of the LPFG was monitored during each modification step. The uniform thickness of the ZIF-8 is shown by the SEM images in Figure 13b. Finally, this proposed sensor was performed with a sensitivity of 0.015 ± 0.001 and 0.018 ± 0.0015 nm/ppm and a LOD of 6.67 and 5.56 ppm for acetone and ethanol, respectively, in [98]. The same group fabricated an LPFG-based carbon dioxide (CO2) sensor modified with HKUST-1 thin film using in situ crystallization and the LbL technique [99]. The detection of CO2 was performed with a LOD of 401 ppm. Moreover, the MOFs can also be used as potential matrices for enzymes’ integration [122]. Zhu et al. reported that the glucose oxidase (GOx)-encapsulated ZIF-8 was coated onto the LPFG via in situ crystallization [100]. A sensitivity of 0.5 nm/mM in the range of 1–8 mM for the detection of glucose was obtained.

5. Reflective LPFG-Based Sensors

Since an LPFG-based sensor can couple light from the fundamental core mode to forward-propagating cladding modes, it therefore produces a set of resonant attenuation bands centered at discrete wavelengths in the transmission spectrum. One of the peculiarities of LPFG-based sensors is their operation in transmission mode, which is inconvenient for some biological applications when they need to be introduced in vial/test tubes. From the point of view of realizing miniaturization, the light emission port and the signal collection port need to be deployed on the same facet. Moreover, bending sensitivity can bring interference of the transmitted optical signal [123].
Therefore, there are some works where the transmission mode operation of the LPFG is transformed in reflection mode operation. Swart, P. L. proposed a single-probe Michelson interferometer based on an LPFG where the interferometer phase shift depends on the RI of the surroundings [124]. Kim D. W. also developed a single-fiber probe based on two interferometers, the reflection-mode LPFG for RI sensing and an intrinsic Fabry–Perot interferometer for temperature measurement [125]. Although the LPFG-based interferometer sensor operated in reflection mode, the total length of the sensor might be at least 4~5 cm due to the nature of the interferometer [124,126], which was inconvenient for in vivo detection. Jiang et al. developed a compact reflective LPFG sensor by coating only the cladding end facet with an aluminum film, and then reflecting only the cladding modes [127]. The length of the proposed device was normally 0.5~3 cm long, which was the same as the conventional LPFG-based sensor. However, the complex coating process was utilized. Rana S. et al. used a cost-effective brush coating method using available silver paste to realize a reflective LPFG sensor. The developed device was performed with a temperature sensitivity coefficient of 0.046 nm/°C in a range between 23 °C and 200 °C [128].
In [129], a reflective LPFG-based sensor with a Sagnac fiber loop mirror (SFLM) for measuring the RI and temperature was fabricated. The simultaneous RI and temperature measurement could be achieved by this device, due to the different sensitivities to RI and temperature of the LPFG and SFLM. Another unavoidable problem of reflective LPFG-based sensors is the generation of undesired interferometric bands that overlap the LPFG attenuation bands [130,131]. Some effective approaches focus on precisely cleaving at the end of the LPFG [123] or polishing after cleaving [132] to obtain a unique attenuation band. In [123], as shown in Figure 14, the end of the grating was precisely cleaved and coated with a reflecting layer. In order to enhance the SRI sensitivity of this device, the HRI overlay of the atactic polystyrene was modified on the surface of the fiber. Then, the poly (methylmethacrylate)-co-methacrylic acid was coated onto the fiber as a bio-functional layer to covalently immobilize the bioreceptor. The detection of class C β-lactamases was obtained down to a concentration of the order of a few tens of nM in PBS buffer.
Villar I. D. et al. [133] proposed a simpler way to obtain a single attenuation band; the end of the fiber was coated with a silver mirror which could absorb the power transmitted through the cladding modes. More interestingly, Dey T. K. et al. [101] removed a portion of the LPFG at an arbitrary location, without the requirement of precise cleaving or polishing. The unwanted resonance bands could be removed by tailoring the PMC of the cladding mode; it also benefited to enhance the RI sensitivity of this device. Finally, an RI sensitivity of ∼1300 nm/RIU was obtained.

6. Conclusions

This review highlights the basic operating principle of LPFG-based sensors and their sensitization and sensitivity enhancement mechanisms for chemical and biomedical applications. The basic principle of LPFG-based biosensors is that the SRI changes can be converted into the measurement of the resonance wavelength shift or transmission loss variation. To enhance the sensitivity of LPFG-based biosensors for chemical and biomedical applications, two main methodologies have been adopted in recent published reports. One is to design an LPFG working at or near a DTP, which can be realized by tuning the grating period, cladding diameter or the functional layer thickness. This methodology has a good performance for the detection of immunoglobulin, bacteria, DNA and other targets. The other one is the MT effect, which can be realized by coating the fiber cladding surface with a proper thickness of HRI materials. This methodology has been proven to perform well in detecting organic gas (e.g., methane and butane) and protein (e.g., biotinylated BSA, C-reactive protein). The combination of these strategies is also reviewed in this paper. On the other hand, the functionalization of LPFG-based biosensors is an indispensable step to achieve specific sensing. As shown in Table 2, we summarize several common functionalization methods corresponding to different kinds of bioreceptors. The APTES silanization is usually applied to covalently bond the antibodies or enzymes, further functionalization with GO can offer device the capability to covalently bond more kinds of bioreceptors due to the abundant functional groups of GO. In addition, LbL assembly, the method of noncovalent functionalization, is also reviewed in this paper. The advantage of this method is that it is more convenient and can precisely control the thickness of the functional layer. This method has been applied to deposit polyelectrolytes for salinity and pH sensing, as well as ion, gas and bacteria detection. Other functionalization methods (e.g., dip-coating and in situ crystallization techniques) have also been reviewed. Moreover, reflective LPFG-based sensors have also been introduced. Although the demonstrated LPFGs in reflection configurations exhibit less sensitivity, they can be introduced in the vial/test tube, which is more convenient and practical for their chemical or biomedical applications.
In this review, it has been shown that the LPFG is a promising sensing platform for chemical and biomedical applications. A meaningful future direction should be exploiting innovative coating materials and functionalization methods to detect more kinds of biomolecules. In addition, the inherent multiplexing capability of OFBS should be utilized in LPFG-based sensors to achieve multi-parameter or multi-target measurements by writing different gratings in the same device. In complex measurement environments, more efforts should be focused on reducing or eliminating the cross-sensitivity (e.g., temperature, strain) effects on LPFG-based sensors.

Author Contributions

Conceptualization, J.C. and X.S.; investigation, J.C. and Y.L.; writing—original draft preparation, J.C.; writing—review and editing, X.S.; supervision, X.S. All authors have read and agreed to the published version of the manuscript.

Funding

This work was funded by the National Natural Science Foundation of China (62275093), the Key R&D Program of Hubei Province (2021BAA036), and the National Key Research and Development Program of China (2018YFE0117400).

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Mittal, S.; Kaur, H.; Gautam, N.; Mantha, A.K. Biosensors for breast cancer diagnosis: A review of bioreceptors, biotransducers and signal amplification strategies. Biosens. Bioelectron. 2017, 88, 217–231. [Google Scholar] [CrossRef] [PubMed]
  2. Mehrotra, P. Biosensors and their applications—A review. J. Oral Biol. Craniofac. Res. 2016, 6, 153–159. [Google Scholar] [CrossRef] [Green Version]
  3. Polley, N.; Basak, S.; Hass, R.; Pacholski, C. Fiber optic plasmonic sensors: Providing sensitive biosensor platforms with minimal lab equipment. Biosens. Bioelectron. 2019, 132, 368–374. [Google Scholar] [CrossRef]
  4. Roriz, P.; Silva, S.; Frazão, O.; Novais, S. Optical Fiber Temperature Sensors and Their Biomedical Applications. Sensors 2020, 20, 2113. [Google Scholar] [CrossRef] [Green Version]
  5. Esposito, F.; Srivastava, A.; Sansone, L.; Giordano, M.; Campopiano, S.; Iadicicco, A. Label-Free Biosensors Based on Long Period Fiber Gratings: A Review. IEEE Sens. J. 2021, 21, 12692–12705. [Google Scholar] [CrossRef]
  6. Wen, H.-Y.; Huang, C.-W.; Li, Y.-L.; Chen, J.-L.; Yeh, Y.-T.; Chiang, C.-C. A Lamping U-Shaped Fiber Biosensor Detector for MicroRNA. Sensors 2020, 20, 1509. [Google Scholar] [CrossRef] [Green Version]
  7. Chen, K.-C.; Li, Y.-L.; Wu, C.-W.; Chiang, C.-C. Glucose Sensor Using U-Shaped Optical Fiber Probe with Gold Nanoparticles and Glucose Oxidase. Sensors 2018, 18, 1217. [Google Scholar] [CrossRef] [Green Version]
  8. Liu, J.; Xing, Y.; Zhou, X.; Chen, G.Y.; Shi, H. Light-sheet skew rays enhanced U-shaped fiber-optic fluorescent immunosensor for Microcystin-LR. Biosens. Bioelectron. 2021, 176, 112902–112908. [Google Scholar] [CrossRef]
  9. Chen, L.; Leng, Y.-K.; Liu, B.; Liu, J.; Wan, S.-P.; Wu, T.; Yuan, J.; Shao, L.; Gu, G.; Fu, Y.Q.J.S.; et al. Ultrahigh-sensitivity label-free optical fiber biosensor based on a tapered singlemode-no core-singlemode coupler for Staphylococcus aureus detection. Sens. Actuators B Chem. 2020, 320, 128283. [Google Scholar] [CrossRef]
  10. Kumar, R.; Leng, Y.; Liu, B.; Zhou, J.; Shao, L.; Yuan, J.; Fan, X.; Wan, S.; Wu, T.; Liu, J.J.B. Bioelectronics, Ultrasensitive biosensor based on magnetic microspheres enhanced microfiber interferometer. Biosens. Bioelectron. 2019, 145, 111563. [Google Scholar] [CrossRef]
  11. Quero, G.; Crescitelli, A.; Paladino, D.; Consales, M.; Buosciolo, A.; Giordano, M.; Cutolo, A.; Cusano, A. Evanescent wave long-period fiber grating within D-shaped optical fibers for high sensitivity refractive index detection. Sens. Actuators B Chem. 2011, 152, 196–205. [Google Scholar] [CrossRef]
  12. Jang, H.S.; Park, K.N.; Kim, J.P.; Sim, S.J.; Kwon, O.J.; Han, Y.-G.; Lee, K.S. Sensitive DNA biosensor based on a long-period grating formed on the side-polished fiber surface. Opt. Express 2009, 17, 3855–3860. [Google Scholar] [CrossRef] [PubMed]
  13. Bekmurzayeva, A.; Dukenbayev, K.; Shaimerdenova, M.; Bekniyazov, I.; Ayupova, T.; Sypabekova, M.; Molardi, C.; Tosi, D. Etched Fiber Bragg Grating Biosensor Functionalized with Aptamers for Detection of Thrombin. Sensors 2018, 18, 4298. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  14. Sypabekova, M.; Korganbayev, S.; González-Vila, Á.; Caucheteur, C.; Shaimerdenova, M.; Ayupova, T.; Bekmurzayeva, A.; Vangelista, L.; Tosi, D. Functionalized etched tilted fiber Bragg grating aptasensor for label-free protein detection. Biosens. Bioelectron. 2019, 146, 111765. [Google Scholar] [CrossRef]
  15. Lobry, M.; Fasseaux, H.; Loyez, M.; Chah, K.; Goormaghtigh, E.; Wattiez, R.; Chiavaioli, F.; Caucheteur, C. Plasmonic Fiber Grating Biosensors Demodulated Through Spectral Envelopes Intersection. J. Light. Technol. 2021, 39, 7288–7295. [Google Scholar] [CrossRef]
  16. Celebanska, A.; Chiniforooshan, Y.; Janik, M.; Mikulic, P.; Sellamuthu, B.; Perreault, J.; Bock, W.J. Bioinspired Carbohydrate-Decorated Long-Period Fiber Grating for Label-Free Bacteria Detection. IEEE Sens. J. 2019, 19, 11965–11971. [Google Scholar] [CrossRef]
  17. Xiao, P.; Sun, Z.; Huang, Y.; Lin, W.; Ge, Y.; Xiao, R.; Li, K.; Li, Z.; Lu, H.; Yang, M.; et al. Development of an optical microfiber immunosensor for prostate specific antigen analysis using a high-order-diffraction long period grating. Opt. Express 2020, 28, 15783–15793. [Google Scholar] [CrossRef]
  18. Shu, X.; Zhang, L.; Bennion, I. Sensitivity Characteristics of Long-Period Fiber Gratings. J. Light. Technol. 2002, 20, 255–266. [Google Scholar]
  19. Pilla, P.; Trono, C.; Baldini, F.; Chiavaioli, F.; Giordano, M.; Cusano, A. Giant sensitivity of long period gratings in transition mode near the dispersion turning point: An integrated design approach. Opt. Lett. 2012, 37, 4152–4154. [Google Scholar] [CrossRef]
  20. Zuppolini, S.; Quero, G.; Consales, M.; Diodato, L.; Vaiano, P.; Venturelli, A.; Santucci, M.; Spyrakis, F.; Costi, M.P.; Giordano, M.; et al. Label-free fiber optic optrode for the detection of class C β-lactamases expressed by drug resistant bacteria. Biomed. Opt. Express 2017, 8, 5191–5205. [Google Scholar] [CrossRef] [Green Version]
  21. Chiavaioli, F.; Janner, D. Fiber Optic Sensing With Lossy Mode Resonances: Applications and Perspectives. J. Light. Technol. 2021, 39, 3855–3870. [Google Scholar] [CrossRef]
  22. Lin, Y.-C.; Chen, L.-Y. Subtle Application of Electrical Field-Induced Lossy Mode Resonance to Enhance Performance of Optical Planar Waveguide Biosensor. Biosensors 2021, 11, 86. [Google Scholar] [CrossRef] [PubMed]
  23. Wang, W.; Mai, Z.; Chen, Y.; Wang, J.; Li, L.; Su, Q.; Li, X.; Hong, X. A label-free fiber optic SPR biosensor for specific detection of C-reactive protein. Sci. Rep. 2017, 7, 16904. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  24. Huang, C.; Zhou, Y.; Yu, G.; Zeng, J.; Li, Q.; Shen, K.; Wu, X.; Guo, R.; Zhang, C.; Zheng, B. Glutathione-functionalized long-period fiber gratings sensor based on surface plasmon resonance for detection of As3+ ions. Nanotechnology 2021, 32, 485501. [Google Scholar] [CrossRef]
  25. Chalyan, T.; Guider, R.; Pasquardini, L.; Zanetti, M.; Falke, F.; Schreuder, E.; Heideman, R.G.; Pederzolli, C.; Pavesi, L. Asymmetric Mach–Zehnder Interferometer Based Biosensors for Aflatoxin M1 Detection. Biosensors 2016, 6, 1. [Google Scholar] [CrossRef] [Green Version]
  26. Janik, M.; Brzozowska, E.; Czyszczoń, P.; Celebańska, A.; Koba, M.; Gamian, A.; Bock, W.J.; Śmietana, M. Optical fiber aptasensor for label-free bacteria detection in small volumes. Sens. Actuators B Chem. 2021, 330, 129316. [Google Scholar] [CrossRef]
  27. Liu, Q.; Ma, Z.; Wu, Q.; Wang, W. The biochemical sensor based on liquid-core photonic crystal fiber filled with gold, silver and aluminum. Opt. Laser Technol. 2020, 130, 106363. [Google Scholar] [CrossRef]
  28. Mahfuz, M.A.; Hossain, M.A.; Haque, E.; Hai, N.H.; Namihira, Y.; Ahmed, F. A Bimetallic-Coated, Low Propagation Loss, Photonic Crystal Fiber Based Plasmonic Refractive Index Sensor. Sensors 2019, 19, 3794. [Google Scholar] [CrossRef] [Green Version]
  29. Consales, M.; Quero, G.; Spaziani, S.; Principe, M.; Micco, A.; Galdi, V.; Cutolo, A.; Cusano, A. Metasurface-Enhanced Lab-on-Fiber Biosensors. Laser Photonics Rev. 2020, 14, 2000180. [Google Scholar] [CrossRef]
  30. Managò, S.; Quero, G.; Zito, G.; Tullii, G.; Galeotti, F.; Pisco, M.; De Luca, A.C.; Cusano, A. Tailoring lab-on-fiber SERS optrodes towards biological targets of different sizes. Sens. Actuators B Chem. 2021, 339, 129321. [Google Scholar] [CrossRef]
  31. Marco, P.; Francesco, G.; Giorgio, G.; Giuseppe, Q.; Andrea, C. Self-assembled periodic patterns on the optical fiber tip by microsphere arrays. In Proceedings of the 24th International Conference on Optical Fibre Sensors, Curitiba, Brazil, 28 September–2 October 2015; p. 96341N. [Google Scholar]
  32. Badmos, A.A.; Sun, Q.; Sun, Z.; Zhang, J.; Yan, Z.; Lutsyk, P.; Rozhin, A.; Zhang, L. Enzyme-functionalized thin-cladding long-period fiber grating in transition mode at dispersion turning point for sugar-level and glucose detection. J. Biomed. Opt. 2017, 22, 027003. [Google Scholar] [CrossRef]
  33. Heidemann, B.R.; Chiamenti, I.; Oliveira, M.M.; Muller, M.; Fabris, J.L. Functionalized Long Period Grating—Plasmonic Fiber Sensor Applied to the Detection of Glyphosate in Water. J. Light. Technol. 2018, 36, 863–870. [Google Scholar] [CrossRef]
  34. Kanka, J. Design of turn-around-point long-period gratings in a photonic crystal fiber for refractometry of gases. Sens. Actuators B Chem. 2013, 182, 16–24. [Google Scholar] [CrossRef]
  35. Gu, Z.; Xu, Y.; Gao, K. Optical fiber long-period grating with solgel coating for gas sensor. Opt. Lett. 2006, 31, 2405–2407. [Google Scholar] [CrossRef]
  36. Wei, W.; Nong, J.; Zhang, G.; Tang, L.; Jiang, X.; Chen, N.; Luo, S.; Lan, G.; Zhu, Y. Graphene-Based Long-Period Fiber Grating Surface Plasmon Resonance Sensor for High-Sensitivity Gas Sensing. Sensors 2017, 17, 2. [Google Scholar] [CrossRef] [Green Version]
  37. Tan, S.-Y.; Lee, S.-C.; Kuramitz, H.; Abd-Rahman, F. A novel hybrid long period fiber grating-diffusive gradient in thin films sensor system for the detection of mercury (II) ions in water. Optik 2019, 194, 163040. [Google Scholar] [CrossRef]
  38. Wang, J.-N. A microfluidic long-period fiber grating sensor platform for chloride ion concentration measurement. Sensors 2011, 11, 8550–8568. [Google Scholar] [CrossRef] [Green Version]
  39. Gan, W.; Xu, Z.; Li, Y.; Bi, W.; Chu, L.; Qi, Q.; Yang, Y.; Zhang, P.; Gan, N.; Dai, S.; et al. Rapid and sensitive detection of Staphylococcus aureus by using a long-period fiber grating immunosensor coated with egg yolk antibody. Biosens. Bioelectron. 2022, 199, 113860. [Google Scholar] [CrossRef]
  40. Vengsarkar, A.M.; Lemaire, P.J.; Judkins, J.B.; Bhatia, V.; Erdogan, T.; Sipe, J.E. Long-period fiber gratings as band-rejection filters. J. Light. Technol. 1996, 14, 58–65. [Google Scholar] [CrossRef]
  41. Patrick, H.J.; Kersey, A.D.; Bucholtz, F. Analysis of the response of long period fiber gratings to external index of refraction. J. Light. Technol. 1998, 16, 1606–1612. [Google Scholar] [CrossRef]
  42. Chiavaioli, F.; Biswas, P.; Trono, C.; Bandyopadhyay, S.; Giannetti, A.; Tombelli, S.; Basumallick, N.; Dasgupta, K.; Baldini, F. Towards sensitive label-free immunosensing by means of turn-around point long period fiber gratings. Biosens. Bioelectron. 2014, 60, 305–310. [Google Scholar] [CrossRef] [PubMed]
  43. Marques, L.; Hernandez, F.U.; James, S.W.; Morgan, S.P.; Clark, M.; Tatam, R.P.; Korposh, S. Highly sensitive optical fibre long period grating biosensor anchored with silica core gold shell nanoparticles. Biosens. Bioelectron. 2016, 75, 222–231. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  44. Del Villar, I.; Cruz, J.L.; Socorro, A.B.; Corres, J.M.; Matias, I.R. Sensitivity optimization with cladding-etched long period fiber gratings at the dispersion turning point. Opt. Express 2016, 24, 17680–17685. [Google Scholar] [CrossRef] [Green Version]
  45. Dandapat, K.; Tripathi, S.M.; Chinifooroshan, Y.; Bock, W.J.; Mikulic, P. Compact and cost-effective temperature-insensitive bio-sensor based on long-period fiber gratings for accurate detection of E. coli bacteria in water. Opt. Lett. 2016, 41, 4198–4201. [Google Scholar] [CrossRef]
  46. Liu, C.; Cai, Q.; Xu, B.; Zhu, W.; Zhang, L.; Zhao, J.; Chen, X. Graphene oxide functionalized long period grating for ultrasensitive label-free immunosensing. Biosens. Bioelectron. 2017, 94, 200–206. [Google Scholar] [CrossRef] [Green Version]
  47. Dey, T.K.; Tombelli, S.; Biswas, P.; Giannetti, A.; Basumallick, N.; Baldini, F.; Bandyopadhyay, S.; Trono, C. Analysis of the Lowest Order Cladding Mode of Long Period Fiber Gratings Near Turn Around Point. J. Light. Technol. 2021, 39, 4006–4012. [Google Scholar] [CrossRef]
  48. Dey, T.K.; Tombelli, S.; Biswas, P.; Giannetti, A.; Basumallick, N.; Baldini, F.; Bandyopadhyay, S.; Trono, C. Label-free immunosensing by long period fiber gratings at the lowest order cladding mode and near turn around point. Opt. Laser Technol. 2021, 142, 107194. [Google Scholar] [CrossRef]
  49. Yang, J.; Zhou, L.; Huang, J.; Tao, C.; Li, X.; Chen, W. Sensitivity enhancing of transition mode long-period fiber grating as methane sensor using high refractive index polycarbonate/cryptophane A overlay deposition. Sens. Actuators B Chem. 2015, 207, 477–480. [Google Scholar] [CrossRef]
  50. Esposito, F.; Zotti, A.; Ranjan, R.; Zuppolini, S.; Borriello, A.; Campopiano, S.; Zarrelli, M.; Iadicicco, A. Single-Ended Long Period Fiber Grating Coated With Polystyrene Thin Film for Butane Gas Sensing. J. Light. Technol. 2018, 36, 825–832. [Google Scholar] [CrossRef]
  51. Esposito, F.; Sansone, L.; Taddei, C.; Campopiano, S.; Giordano, M.; Iadicicco, A. Ultrasensitive biosensor based on long period grating coated with polycarbonate-graphene oxide multilayer. Sens. Actuators B Chem. 2018, 274, 517–526. [Google Scholar] [CrossRef]
  52. Piestrzyńska, M.; Dominik, M.; Kosiel, K.; Janczuk-Richter, M.; Szot-Karpińska, K.; Brzozowska, E.; Shao, L.; Niedziółka-Jonsson, J.; Bock, W.J.; Śmietana, M. Ultrasensitive tantalum oxide nano-coated long-period gratings for detection of various biological targets. Biosens. Bioelectron. 2019, 133, 8–15. [Google Scholar] [CrossRef]
  53. Saha, N.; Kumar, A. Highly Sensitive Refractive Index Sensor Based on Mode Transition in a Dual Resonance Long Period Grating Inscribed Ridge Waveguide. J. Light. Technol. 2019, 37, 5576–5582. [Google Scholar] [CrossRef]
  54. Li, Z.; Zhu, H. Sensing performance of surface waveguide modes excited in long-period fiber grating with gold–silicon nanocoatings. Opt. Lett. 2021, 46, 266–269. [Google Scholar] [CrossRef] [PubMed]
  55. Esposito, F.; Srivastava, A.; Sansone, L.; Giordano, M.; Campopiano, S.; Iadicicco, A. Sensitivity Enhancement in Long Period Gratings by Mode Transition in Uncoated Double Cladding Fibers. IEEE Sens. J. 2020, 20, 234–241. [Google Scholar] [CrossRef]
  56. Esposito, F.; Sansone, L.; Srivastava, A.; Baldini, F.; Campopiano, S.; Chiavaioli, F.; Giordano, M.; Giannetti, A.; Iadicicco, A. Long period grating in double cladding fiber coated with graphene oxide as high-performance optical platform for biosensing. Biosens. Bioelectron. 2021, 172, 112747. [Google Scholar] [CrossRef] [PubMed]
  57. Esposito, F.; Sansone, L.; Srivastava, A.; Cusano, A.M.; Campopiano, S.; Giordano, M.; Iadicicco, A. Label-free detection of vitamin D by optical biosensing based on long period fiber grating. Sens. Actuators B Chem. 2021, 347, 130637. [Google Scholar] [CrossRef]
  58. Smietana, M.; Koba, M.; Brzozowska, E.; Krogulski, K.; Nakonieczny, J.; Wachnicki, L.; Mikulic, P.; Godlewski, M.; Bock, W.J. Label-free sensitivity of long-period gratings enhanced by atomic layer deposited TiO2 nano-overlays. Opt. Express 2015, 23, 8441–8453. [Google Scholar] [CrossRef] [Green Version]
  59. Śmietana, M.; Koba, M.; Mikulic, P.; Bock, W.J. Combined Plasma-Based Fiber Etching and Diamond-Like Carbon Nanooverlay Deposition for Enhancing Sensitivity of Long-Period Gratings. J. Light. Technol. 2016, 34, 4615–4619. [Google Scholar] [CrossRef]
  60. Del Villar, I. Ultrahigh-sensitivity sensors based on thin-film coated long period gratings with reduced diameter, in transition mode and near the dispersion turning point. Opt. Express 2015, 23, 8389–8398. [Google Scholar] [CrossRef]
  61. Zou, F.; Liu, Y.; Mou, C.; Zhu, S. Optimization of Refractive Index Sensitivity in Nanofilm-Coated Long-Period Fiber Gratings Near the Dispersion Turning Point. J. Light. Technol. 2020, 38, 889–897. [Google Scholar] [CrossRef]
  62. Shu, X.; Zhu, X.; Wang, Q.; Jiang, S.; Shi, W.; Huang, Z.; Huang, D.J.E.L. Dual resonant peaks of LP015 cladding mode in long-period gratings. Electron. Lett 1999, 35, 649–651. [Google Scholar] [CrossRef]
  63. Biswas, P.; Basumallick, N.; Bandyopadhyay, S.; Dasgupta, K.; Ghosh, A.; Bandyopadhyay, S. Sensitivity Enhancement of Turn-Around-Point Long Period Gratings By Tuning Initial Coupling Condition. IEEE Sens. J. 2015, 15, 1240–1245. [Google Scholar] [CrossRef]
  64. Liu, L.; Marques, L.; Correia, R.; Morgan, S.P.; Lee, S.-W.; Tighe, P.; Fairclough, L.; Korposh, S. Highly sensitive label-free antibody detection using a long period fibre grating sensor. Sens. Actuators B Chem. 2018, 271, 24–32. [Google Scholar] [CrossRef]
  65. Smietana, M.; Bock, W.J.; Mikulic, P.; Ng, A.; Chinnappan, R.; Zourob, M. Detection of bacteria using bacteriophages as recognition elements immobilized on long-period fiber gratings. Opt. Express 2011, 19, 7971–7978. [Google Scholar] [CrossRef] [PubMed]
  66. Koba, M.; Śmietana, M.; Brzozowska, E.; Górska, S.; Janik, M.; Mikulic, P.; Cusano, A.; Bock, W.J. Bacteriophage adhesin-coated long-period grating-based sensor: Bacteria detection specificity. J. Light. Technol. 2016, 34, 4531–4536. [Google Scholar] [CrossRef]
  67. Chen, X.; Zhang, L.; Zhou, K.; Davies, E.; Sugden, K.; Bennion, I.; Hughes, M.; Hine, A. Real-time detection of DNA interactions with long-period fiber-grating-based biosensor. Opt. Lett. 2007, 32, 2541–2543. [Google Scholar] [CrossRef] [PubMed]
  68. Chen, X.; Liu, C.; Hughes, M.D.; Nagel, D.A.; Hine, A.V.; Zhang, L. EDC-mediated oligonucleotide immobilization on a long period grating optical biosensor. J. Biosens. Bioelectron. 2015, 6, 1000173. [Google Scholar] [CrossRef] [Green Version]
  69. McCutcheon, K.; Bandara, A.B.; Zuo, Z.; Heflin, J.R.; Inzana, T.J. The Application of a Nanomaterial Optical Fiber Biosensor Assay for Identification of Brucella Nomenspecies. Biosensors 2019, 9, 64. [Google Scholar] [CrossRef] [Green Version]
  70. Wang, Z.; Heflin, J.R.; Van Cott, K.; Stolen, R.H.; Ramachandran, S.; Ghalmi, S. Biosensors employing ionic self-assembled multilayers adsorbed on long-period fiber gratings. Sens. Actuators B Chem. 2009, 139, 618–623. [Google Scholar] [CrossRef]
  71. Dyankov, G.; Eftimov, T.A.; Malinowski, N.; Belina, E.; Kisov, H.; Mikulic, P.; Bock, W.J. A highly efficient biosensor based on MAPLE deposited hemoglobin on LPGs around phase matching turning point. Opt. Laser Technol. 2020, 123, 105907. [Google Scholar] [CrossRef]
  72. Korposh, S.; Chianella, I.; Guerreiro, A.; Caygill, S.; Piletsky, S.; James, S.W.; Tatam, R.P. Selective vancomycin detection using optical fibre long period gratings functionalised with molecularly imprinted polymer nanoparticles. Analyst 2014, 139, 2229–2236. [Google Scholar] [CrossRef] [PubMed]
  73. Janczuk-Richter, M.; Gromadzka, B.; Richter, Ł.; Panasiuk, M.; Zimmer, K.; Mikulic, P.; Bock, W.J.; Maćkowski, S.; Śmietana, M.; Niedziółka Jönsson, J. Immunosensor Based on Long-Period Fiber Gratings for Detection of Viruses Causing Gastroenteritis. Sensors 2020, 20, 813. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  74. Celebanska, A.; Chiniforooshan, Y.; Janik, M.; Mikulic, P.; Sellamuthu, B.; Walsh, R.; Perreault, J.; Bock, W.J. Label-free cocaine aptasensor based on a long-period fiber grating. Opt. Lett. 2019, 44, 2482–2485. [Google Scholar] [CrossRef]
  75. Tripathi, S.M.; Bock, W.J.; Mikulic, P.; Chinnappan, R.; Ng, A.; Tolba, M.; Zourob, M. Long period grating based biosensor for the detection of Escherichia coli bacteria. Biosens. Bioelectron. 2012, 35, 308–312. [Google Scholar] [CrossRef] [PubMed]
  76. Villar, I.D.; Matías, I.R.; Arregui, F.J.; Lalanne, P. Optimization of sensitivity in Long Period Fiber Gratings with overlay deposition. Opt. Express 2005, 13, 56–69. [Google Scholar] [CrossRef] [Green Version]
  77. Cusano, A.; Iadicicco, A.; Pilla, P.; Contessa, L.; Campopiano, S.; Cutolo, A.; Giordano, M. Cladding mode reorganization in high-refractive-index-coated long-period gratings: Effects on the refractive-index sensitivity. Opt. Lett. 2005, 30, 2536–2538. [Google Scholar] [CrossRef]
  78. Tan, K.M.; Tay, C.M.; Tjin, S.C.; Chan, C.C.; Rahardjo, H. High relative humidity measurements using gelatin coated long-period grating sensors. Sens. Actuators B Chem. 2005, 110, 335–341. [Google Scholar] [CrossRef]
  79. Śmietana, M.; Koba, M.; Mikulic, P.; Bock, W.J. Measurements of reactive ion etching process effect using long-period fiber gratings. Opt. Express 2014, 22, 5986–5994. [Google Scholar] [CrossRef] [Green Version]
  80. Baliyan, A.; Sital, S.; Tiwari, U.; Gupta, R.; Sharma, E.K. Long period fiber grating based sensor for the detection of triacylglycerides. Biosens. Bioelectron. 2016, 79, 693–700. [Google Scholar] [CrossRef]
  81. Wu, C.-W. S-shaped long period fiber grating glucose concentration biosensor based on immobilized glucose oxidase. Optik 2020, 203, 163960. [Google Scholar] [CrossRef]
  82. Kaushik, S.; Tiwari, U.; Nilima; Prashar, S.; Das, B.; Sinha, R.K. Label-free detection of E scherichia coli bacteria by cascaded chirped long period gratings immunosensor. Rev. Sci. Instrum. 2019, 90, 025003. [Google Scholar] [CrossRef] [PubMed]
  83. Queirós, R.B.; Gouveia, C.; Fernandes, J.R.A.; Jorge, P.A.S. Evanescent wave DNA-aptamer biosensor based on long period gratings for the specific recognition of E. coli outer membrane proteins. Biosens. Bioelectron. 2014, 62, 227–233. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  84. Gambhir, M.; Gupta, S.; John, P.; Mahakud, R.; Kumar, J.; Prakash, O.J.F.; Optics, I. Surface modified long period fiber grating sensor for rapid detection of aspergillus niger fungal spores. Iber Integr. Opt. 2018, 37, 79–91. [Google Scholar] [CrossRef]
  85. Liu, C.; Xu, B.J.; Zhou, L.; Sun, Z.; Mao, H.J.; Zhao, J.L.; Zhang, L.; Chen, X. Graphene oxide functionalized long period fiber grating for highly sensitive hemoglobin detection. Sens. Actuators B Chem. 2018, 261, 91–96. [Google Scholar] [CrossRef] [Green Version]
  86. Wang, R.; Ren, Z.; Kong, D.; Hu, B.; He, Z. Highly sensitive label-free biosensor based on graphene-oxide functionalized micro-tapered long period fiber grating. Opt. Mater. 2020, 109, 110253. [Google Scholar] [CrossRef]
  87. Wang, R.; Wu, H.; Qi, M.; Han, J.; Ren, Z. Bovine Serum Albumin Detection by Graphene Oxide Coated Long-Period Fiber Grating. Photonic Sens. 2022, 12, 220305. [Google Scholar] [CrossRef]
  88. Kang, X.; Wang, R.; Jiang, M.; Li, E.; Li, Y.; Yan, X.; Wang, T.; Ren, Z. Polydopamine functionalized graphene oxide for high sensitivity micro-tapered long period fiber grating sensor and its application in detection Co2+ ions. Opt. Fiber Technol. 2022, 68, 102807. [Google Scholar] [CrossRef]
  89. Wang, R.; Ren, Z.; Kong, D.; Wu, H.; Hu, B.; He, Z. Graphene oxide functionalized micro-tapered long-period fiber grating for sensitive heavy metal sensing. Appl. Phys. Express 2020, 13, 067001. [Google Scholar] [CrossRef]
  90. Yang, F.; Sukhishvili, S.; Du, H.; Tian, F. Marine salinity sensing using long-period fiber gratings enabled by stimuli-responsive polyelectrolyte multilayers. Sens. Actuators B Chem. 2017, 253, 745–751. [Google Scholar] [CrossRef]
  91. Yang, F.; Hlushko, R.; Wu, D.; Sukhishvili, S.A.; Du, H.; Tian, F. Ocean Salinity Sensing Using Long-Period Fiber Gratings Functionalized with Layer-by-Layer Hydrogels. ACS Omega 2019, 4, 2134–2141. [Google Scholar] [CrossRef] [Green Version]
  92. Wang, T.; Yasukochi, W.; Korposh, S.; James, S.W.; Tatam, R.P.; Lee, S.-W. A long period grating optical fiber sensor with nano-assembled porphyrin layers for detecting ammonia gas. Sens. Actuators B Chem. 2016, 228, 573–580. [Google Scholar] [CrossRef]
  93. Tan, S.-Y.; Lee, S.-C.; Okazaki, T.; Kuramitz, H.; Abd-Rahman, F. Detection of mercury (II) ions in water by polyelectrolyte–gold nanoparticles coated long period fiber grating sensor. Opt. Commun. 2018, 419, 18–24. [Google Scholar] [CrossRef]
  94. Ni, Y.-Q.; Ding, S.; Han, B.; Wang, H. Layer-by-layer assembly of polyelectrolytes-wrapped multi-walled carbon nanotubes on long period fiber grating sensors. Sens. Actuators B Chem. 2019, 301, 127120. [Google Scholar] [CrossRef]
  95. Yang, F.; Chang, T.-L.; Liu, T.; Wu, D.; Du, H.; Liang, J.; Tian, F. Label-free detection of Staphylococcus aureus bacteria using long-period fiber gratings with functional polyelectrolyte coatings. Biosens. Bioelectron. 2019, 133, 147–153. [Google Scholar] [CrossRef]
  96. Qin, X.; Feng, W.; Yang, X.; Wei, J.; Huang, G. Molybdenum sulfide/citric acid composite membrane-coated long period fiber grating sensor for measuring trace hydrogen sulfide gas. Sens. Actuators B Chem. 2018, 272, 60–68. [Google Scholar] [CrossRef]
  97. Xu, B.; Huang, J.; Xu, X.; Zhou, A.; Ding, L. Ultrasensitive NO Gas Sensor Based on the Graphene Oxide-Coated Long-Period Fiber Grating. ACS Appl. Mater. Inter. 2019, 11, 40868–40874. [Google Scholar] [CrossRef]
  98. Hromadka, J.; Tokay, B.; Correia, R.; Morgan, S.P.; Korposh, S. Highly sensitive volatile organic compounds vapour measurements using a long period grating optical fibre sensor coated with metal organic framework ZIF-8. Sens. Actuators B Chem. 2018, 260, 685–692. [Google Scholar] [CrossRef]
  99. Hromadka, J.; Tokay, B.; Correia, R.; Morgan, S.P.; Korposh, S. Carbon dioxide measurements using long period grating optical fibre sensor coated with metal organic framework HKUST-1. Sens. Actuators B Chem. 2018, 255, 2483–2494. [Google Scholar] [CrossRef]
  100. Zhu, G.; Zhang, M.; Lu, L.; Lou, X.; Dong, M.; Zhu, L. Metal-organic framework/enzyme coated optical fibers as waveguide-based biosensors. Sens. Actuators B Chem. 2019, 288, 12–19. [Google Scholar] [CrossRef]
  101. Wen, H.-Y.; Wang, S.-F.; Li, C.-H.; Yeh, Y.-T.; Chiang, C.-C. Real-Time and Sensitive Immunosensor for Label-Free Detection of Specific Antigen with a Comb of Microchannel Long-Period Fiber Grating. Anal. Chem. 2020, 92, 15989–15996. [Google Scholar] [CrossRef]
  102. Eftimov, T.; Janik, M.; Koba, M.; Śmietana, M.; Mikulic, P.; Bock, W. Long-Period Gratings and Microcavity In-Line Mach Zehnder Interferometers as Highly Sensitive Optical Fiber Platforms for Bacteria Sensing. Sensors 2020, 20, 3372. [Google Scholar] [CrossRef]
  103. DeLisa, M.P.; Zhang, Z.; Shiloach, M.; Pilevar, S.; Davis, C.C.; Sirkis, J.S.; Bentley, W.E. Evanescent Wave Long-Period Fiber Bragg Grating as an Immobilized Antibody Biosensor. Anal. Chem. 2000, 72, 2895–2900. [Google Scholar] [CrossRef] [PubMed]
  104. Yadav, A.R.; Sriram, R.; Carter, J.A.; Miller, B.L. Comparative study of solution–phase and vapor–phase deposition of aminosilanes on silicon dioxide surfaces. Mater. Sci. Eng. C 2014, 35, 283–290. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  105. Saengdee, P.; Chaisriratanakul, W.; Bunjongpru, W.; Sripumkhai, W.; Srisuwan, A.; Jeamsaksiri, W.; Hruanun, C.; Poyai, A.; Promptmas, C. Surface modification of silicon dioxide, silicon nitride and titanium oxynitride for lactate dehydrogenase immobilization. Biosens. Bioelectron. 2015, 67, 134–138. [Google Scholar] [CrossRef] [PubMed]
  106. Lee, Y.; Kim, J.; Kim, S.; Jang, W.-D.; Park, S.; Koh, W.-G. Protein-conjugated, glucose-sensitive surface using fluorescent dendrimer porphyrin. J. Mater. Chem. 2009, 19, 5643–5647. [Google Scholar] [CrossRef]
  107. Chen, D.; Feng, H.; Li, J. Graphene Oxide: Preparation, Functionalization, and Electrochemical Applications. Chem. Rev. 2012, 112, 6027–6053. [Google Scholar] [CrossRef]
  108. Georgakilas, V.; Otyepka, M.; Bourlinos, A.B.; Chandra, V.; Kim, N.; Kemp, K.C.; Hobza, P.; Zboril, R.; Kim, K.S. Functionalization of Graphene: Covalent and Non-Covalent Approaches, Derivatives and Applications. Chem. Rev. 2012, 112, 6156–6214. [Google Scholar] [CrossRef]
  109. Huang, C.; Bai, H.; Li, C.; Shi, G. A graphene oxide/hemoglobin composite hydrogel for enzymatic catalysis in organic solvents. Chem. Commun. 2011, 47, 4962–4964. [Google Scholar] [CrossRef] [Green Version]
  110. Wang, R.; Kang, X.; Kong, D.; Jiang, M.; Ren, Z.; Hu, B.; He, Z. Highly sensitive metal ion sensing by graphene oxide functionalized micro-tapered long-period fiber grating. Analyst 2022, 147, 3025–3034. [Google Scholar] [CrossRef]
  111. Ariga, K.; Yamauchi, Y.; Rydzek, G.; Ji, Q.; Yonamine, Y.; Wu, K.C.-W.; Hill, J.P. Layer-by-layer nanoarchitectonics: Invention, innovation, and evolution. Chem. Lett. 2014, 43, 36–68. [Google Scholar] [CrossRef]
  112. Tian, F.; Kanka, J.; Sukhishvili, S.A.; Du, H. Photonic crystal fiber for layer-by-layer assembly and measurements of polyelectrolyte thin films. Opt. Lett. 2012, 37, 4299–4301. [Google Scholar] [CrossRef] [PubMed]
  113. Lee, T.; Min, S.H.; Gu, M.; Jung, Y.K.; Lee, W.; Lee, J.U.; Seong, D.G.; Kim, B.-S. Layer-by-Layer Assembly for Graphene-Based Multilayer Nanocomposites: Synthesis and Applications. Chem. Mater. 2015, 27, 3785–3796. [Google Scholar] [CrossRef]
  114. Chen, R.; Liu, W.; Huang, G.; Wang, D.; Qin, X.; Feng, W. Hydrogen sulfide sensor based on tapered fiber sandwiched between two molybdenum disulfide/citric acid composite membrane coated long-period fiber gratings. Appl. Opt. 2018, 57, 9755–9759. [Google Scholar] [CrossRef]
  115. Xu, B.; Huang, J.; Ding, L.; Zhang, H.; Zhang, H. A Sensitive Ammonia Sensor Using Long Period Fiber Grating Coated With Graphene Oxide/Cellulose Acetate. IEEE Sens. J. 2021, 21, 16691–16700. [Google Scholar] [CrossRef]
  116. Furukawa, H.; Cordova, K.E.; O’Keeffe, M.; Yaghi, O.M. The chemistry and applications of metal-organic frameworks. Science 2013, 341, 1230444. [Google Scholar] [CrossRef] [Green Version]
  117. Zhou, H.-C.; Long, J.R.; Yaghi, O.M. Introduction to Metal–Organic Frameworks. Chem. Rev. 2012, 112, 673–674. [Google Scholar] [CrossRef] [PubMed]
  118. Mueller, U.; Schubert, M.; Teich, F.; Puetter, H.; Schierle-Arndt, K.; Pastré, J. Metal–organic frameworks—Prospective industrial applications. J. Mater. Chem. 2006, 16, 626–636. [Google Scholar] [CrossRef]
  119. Zhang, J.; Tang, X.; Dong, J.; Wei, T.; Xiao, H. Zeolite thin film-coated long period fiber grating sensor for measuring trace organic vapors. Sens. Actuators B Chem. 2009, 135, 420–425. [Google Scholar] [CrossRef]
  120. Lu, G.; Hupp, J.T. Metal−Organic Frameworks as Sensors: A ZIF-8 Based Fabry−Pérot Device as a Selective Sensor for Chemical Vapors and Gases. J. Am. Chem. Soc. 2010, 132, 7832–7833. [Google Scholar] [CrossRef] [Green Version]
  121. Hromadka, J.; Tokay, B.; James, S.; Tatam, R.P.; Korposh, S. Optical fibre long period grating gas sensor modified with metal organic framework thin films. Sens. Actuators B Chem. 2015, 221, 891–899. [Google Scholar] [CrossRef]
  122. Mehta, J.; Bhardwaj, N.; Bhardwaj, S.K.; Kim, K.-H.; Deep, A. Recent advances in enzyme immobilization techniques: Metal-organic frameworks as novel substrates. Coord. Chem. Rev. 2016, 322, 30–40. [Google Scholar] [CrossRef]
  123. Quero, G.; Zuppolini, S.; Consales, M.; Diodato, L.; Vaiano, P.; Venturelli, A.; Santucci, M.; Spyrakis, F.; Costi, M.P.; Giordano, M.; et al. Long period fiber grating working in reflection mode as valuable biosensing platform for the detection of drug resistant bacteria. Sens. Actuators B Chem. 2016, 230, 510–520. [Google Scholar] [CrossRef]
  124. Pieter, L.S. Long-period grating Michelson refractometric sensor. Meas. Sci. Technol. 2004, 15, 1576–1580. [Google Scholar]
  125. Kim, D.W.; Shen, F.; Chen, X.; Wang, A. Simultaneous measurement of refractive index and temperature based on a reflection-mode long-period grating and an intrinsic Fabry–Perot interferometer sensor. Opt. Lett. 2005, 30, 3000–3002. [Google Scholar] [CrossRef]
  126. Jiang, M.; Guan, Z.G.; He, S. Multiplexing Scheme for Self-Interfering Long-Period Fiber Gratings Using a Low-Coherence Reflectometry. IEEE Sens. J. 2007, 7, 1663–1667. [Google Scholar] [CrossRef]
  127. Jiang, M.; Zhang, A.P.; Wang, Y.-C.; Tam, H.-Y.; He, S. Fabrication of a compact reflective long-period grating sensor with a cladding-mode-selective fiber end-face mirror. Opt. Express 2009, 17, 17976–17982. [Google Scholar] [CrossRef] [Green Version]
  128. Sohel, R.; Nirmala, K.; Harish, S. Reflective long period grating based temperature sensor. Opt. Compon. Mater. 2021, 11682, 1168219. [Google Scholar]
  129. Yuan, J.; Zhao, C.-L.; Zhou, Y.; Yu, X.; Kang, J.; Wang, J.; Jin, S. Reflective long-period fiber grating-based sensor with Sagnac fiber loop mirror for simultaneous measurement of refractive index and temperature. Appl. Opt. 2014, 53, H85–H90. [Google Scholar] [CrossRef] [PubMed]
  130. Kim, D.W.; Zhang, Y.; Cooper, K.L.; Wang, A. In-fiber reflection mode interferometer based on a long-period grating for external refractive-index measurement. Appl. Opt. 2005, 44, 5368–5373. [Google Scholar] [CrossRef] [Green Version]
  131. Dey, T.K.; Biswas, P.; Basumallick, N.; Bandyopadhyay, S.; Bandyopadhyay, S. Realization of Long Period Fiber Grating in Reflection Mode Operating Near Turn Around Point. IEEE Sens. J. 2017, 17, 4100–4106. [Google Scholar] [CrossRef]
  132. Jie, H.; Xinwei, L.; Amardeep, K.; Hanzheng, W.; Lei, Y.; Hai, X. Reflection-based phase-shifted long period fiber grating for simultaneous measurement of temperature and refractive index. Opt. Eng. 2013, 52, 014404. [Google Scholar]
  133. Villar, I.D.; Socorro, A.B.; Corres, J.M.; Matias, I.R.; Cruz, J.L.; Rego, G. Etched LPFGs in Reflective Configuration for Sensitivity and Attenuation Band Depth Increase. IEEE Photonic Technol. Lett. 2016, 28, 1077–1080. [Google Scholar] [CrossRef]
Figure 1. The growth of publications as a function of years for OFBS. Data from Web of Science.
Figure 1. The growth of publications as a function of years for OFBS. Data from Web of Science.
Sensors 23 00542 g001
Figure 2. Schematic illustration of OFBS based on an LPFG.
Figure 2. Schematic illustration of OFBS based on an LPFG.
Sensors 23 00542 g002
Figure 3. Calculated variation of mode resonance wavelength with LPFG period. (a) Modes m = 1 to m = 10. (b) Modes m = 11 to m = 20. (c) Modes m = 21 to m = 30. The small circles locate the turning points of the slopes of the curves, and the LPFG exhibits greatest sensitivity in the region between the two dotted lines. Adopted with from [18]. Under a Creative Commons license.
Figure 3. Calculated variation of mode resonance wavelength with LPFG period. (a) Modes m = 1 to m = 10. (b) Modes m = 11 to m = 20. (c) Modes m = 21 to m = 30. The small circles locate the turning points of the slopes of the curves, and the LPFG exhibits greatest sensitivity in the region between the two dotted lines. Adopted with from [18]. Under a Creative Commons license.
Sensors 23 00542 g003
Figure 4. (a) PMC for LP0,12 cladding mode as a function of the fiber diameter with a grating period of 165 mm (solid black line corresponds to the non-etched fiber, whereas solid dark gray line corresponds to the closest curve to the DTP condition). (b) Simulated spectra of LPFG with grating period of 165 µm for decreasing thickness of the fiber diameter dclad from 125 µm up to 123.4 µm, detailing the evolution of the dual resonance bands up to DTP (solid dark grey line). Reprinted with permission from [42]. Copyright © 2014 Elsevier B.V.
Figure 4. (a) PMC for LP0,12 cladding mode as a function of the fiber diameter with a grating period of 165 mm (solid black line corresponds to the non-etched fiber, whereas solid dark gray line corresponds to the closest curve to the DTP condition). (b) Simulated spectra of LPFG with grating period of 165 µm for decreasing thickness of the fiber diameter dclad from 125 µm up to 123.4 µm, detailing the evolution of the dual resonance bands up to DTP (solid dark grey line). Reprinted with permission from [42]. Copyright © 2014 Elsevier B.V.
Sensors 23 00542 g004
Figure 5. Schematic illustration of the layer-by-layer deposition of a (PAH/SiO2:Au)2 film onto an LPFG. Adopted from [43]. Under a Creative Commons license.
Figure 5. Schematic illustration of the layer-by-layer deposition of a (PAH/SiO2:Au)2 film onto an LPFG. Adopted from [43]. Under a Creative Commons license.
Sensors 23 00542 g005
Figure 6. (a) The structure of multilayer fibers. (b) Numerical wavelength shift of the attenuation band versus PC overlay thickness. Reprinted with permission from [51]. Copyright © 2018 Elsevier B.V.
Figure 6. (a) The structure of multilayer fibers. (b) Numerical wavelength shift of the attenuation band versus PC overlay thickness. Reprinted with permission from [51]. Copyright © 2018 Elsevier B.V.
Sensors 23 00542 g006
Figure 7. Schematic picture for the detection of vitamin D based on an LPFG in DCF with GO layer. (a) Overall schematic picture of the device; (b) Details regarding biofunctionalized fiber surface and sensing mechanism (not to scale). Adopted from [57]. Copyright © 2021, Elsevier.
Figure 7. Schematic picture for the detection of vitamin D based on an LPFG in DCF with GO layer. (a) Overall schematic picture of the device; (b) Details regarding biofunctionalized fiber surface and sensing mechanism (not to scale). Adopted from [57]. Copyright © 2021, Elsevier.
Sensors 23 00542 g007
Figure 8. Transmission spectra and resonance wavelength shift in different range of SRI. (a) 65 nm TiO2 nanofilm, Λ = 230.5 μm. (b) 15 nm TiO2 nanofilm, Λ = 237 μm. (c,d) 50 nm TiO2 nanofilm, Λ = 230 μm. Adopted from [61]. Under a Creative Commons license.
Figure 8. Transmission spectra and resonance wavelength shift in different range of SRI. (a) 65 nm TiO2 nanofilm, Λ = 230.5 μm. (b) 15 nm TiO2 nanofilm, Λ = 237 μm. (c,d) 50 nm TiO2 nanofilm, Λ = 230 μm. Adopted from [61]. Under a Creative Commons license.
Sensors 23 00542 g008
Figure 9. Immobilization of enzymes to create the bio-recognition layer on the optical fiber probe. Reprinted with permission from [80]. Copyright © 2015 Elsevier B.V.
Figure 9. Immobilization of enzymes to create the bio-recognition layer on the optical fiber probe. Reprinted with permission from [80]. Copyright © 2015 Elsevier B.V.
Sensors 23 00542 g009
Figure 10. Schematic of GO deposition on LPFG-based device. (a) The process of alkaline treatment, (b) APTES silanization, (c) the epoxy group of GO reacted with amino group of APTES-silanized fiber surface, and (d) GO nanosheets were deposited onto fiber surface. Reprinted with permission from [85]. Copyright © 2018 Elsevier B.V.
Figure 10. Schematic of GO deposition on LPFG-based device. (a) The process of alkaline treatment, (b) APTES silanization, (c) the epoxy group of GO reacted with amino group of APTES-silanized fiber surface, and (d) GO nanosheets were deposited onto fiber surface. Reprinted with permission from [85]. Copyright © 2018 Elsevier B.V.
Sensors 23 00542 g010
Figure 11. Fabrication of a q37P4VP hydrogel coating. Adopted from [91]. Under a Creative Commons license.
Figure 11. Fabrication of a q37P4VP hydrogel coating. Adopted from [91]. Under a Creative Commons license.
Sensors 23 00542 g011
Figure 12. SEM images of (a) the side surface of the LPFG and (b) cross section of the composite membrane-coated LPFG. Reprinted with permission from [96]. Copyright © 2018 Elsevier B.V.
Figure 12. SEM images of (a) the side surface of the LPFG and (b) cross section of the composite membrane-coated LPFG. Reprinted with permission from [96]. Copyright © 2018 Elsevier B.V.
Sensors 23 00542 g012
Figure 13. (a) ZIF-8 fabrication methodology. (b) Top view and cross-sectional SEM images of ZIF-8 films grown on glass substrates. Adopted from [121]. Under a Creative Commons license.
Figure 13. (a) ZIF-8 fabrication methodology. (b) Top view and cross-sectional SEM images of ZIF-8 films grown on glass substrates. Adopted from [121]. Under a Creative Commons license.
Sensors 23 00542 g013
Figure 14. (a) Schematic view of the final reflective LPFG transducer; (b) the experimental and numerical SRI sensitivity; (c) a photograph showing the reflective LPFG biosensor probe developed in this work. Reprinted with permission from [123]. Copyright © 2016 Elsevier B.V.
Figure 14. (a) Schematic view of the final reflective LPFG transducer; (b) the experimental and numerical SRI sensitivity; (c) a photograph showing the reflective LPFG biosensor probe developed in this work. Reprinted with permission from [123]. Copyright © 2016 Elsevier B.V.
Sensors 23 00542 g014
Table 1. Comparison different methods to enhance LPFG-based biosensors.
Table 1. Comparison different methods to enhance LPFG-based biosensors.
Enhanced MethodConfigurationTargetRangeLOD or SensitivityRef.
DTPSM, etched fiber claddingAnti-IgG1–100 μg/mL70 ng/mL[42]
DTPB-Ge co-doped fiberSV0.3–2.7 μM2.5 nM[43]
DTPSM, etched fiber cladding-RI: 1.353–1.4138734 nm/RIU[44]
DTPSM, Λ = 226.8 μm, 358 μm-RI: 1.333–1.3531929 nm/RIU[45]
DTPSM, Λ = 162 μm-RI: 1.333–1.3472538 nm/RIU[46]
DTPSM, thin cladding fiber--4298.2 nm/RIU[32]
DTPSM, etched fiber cladding.-RI: 1.3333–1.33997200 nm/RIU[16]
DTPEtched fiber cladding-RI: 1.333–1.33358751 nm/RIU[47]
DTPSM, etched fiber cladding.Anti-IgG0.1–100 μg/mL0.16 ng/mL[48]
MTPC/cryptophane A overlay--3500 nm/RIU[49]
MTAtactic polystyrene overlayButane~1.0 vol%−2.2 nm/vol%[50]
MTPC/GO overlayBSA0.1–1000 aM0.2 aM[51]
MTTaOx overlay-RI: 1.335–1.34511,500 nm/RIU[52]
MTSi3N4 overlay-RI: around 1.3310,000 nm/RIU[53]
MTAu-Si overlay-RI: around 1.3157267.7 nm/RIU[54]
MTDCF-RI: water-like420 nm/RIU[55]
MTDCFC-reactive protein1–100 μg/mL0.15 ng/mL[56]
MTDCFvitamin D1–1000 ng/mL1 ng/mL[57]
DTP+MTTiO2 overlay-RI: 1.334–1.3406200 nm/RIU[58]
DTP+MTDiamond-like carbon nano overlay-RI: 1.3344–1.335512,000 nm/RIU[59]
RI: 1.340–1.3562000 nm/RIU
DTP+MTThin film with RI of 1.55-RI: 1.330–1.331143000 nm/RIU[60]
DTP+MTTiO2 overlay-RI: 1.336–1.339710,000 nm/RIU[61]
RI: 1.392–1.397115,000 nm/RIU
RI: 1.44–1.443623,000 nm/RIU
RI: 1.4526–1.456142,000 nm/RIU
Abbreviations: dispersion turning point (DTP), mode transition (MT), single mode (SM), double cladding fiber (DCF).
Table 2. Comparison of different reports of the functionalization of LPFG-based biosensors.
Table 2. Comparison of different reports of the functionalization of LPFG-based biosensors.
Functionalization MethodBioreceptorTargetRangLOD or SensitivityRef.
APTES silanizationLipase enzymeTriacylglycerides-0.2 mM[80]
APTES silanizationGlucose oxidaseGlucose0∼1 wt%6.229 dB/wt%[81]
APTES silanizationIgYStaphylococcus aureus102–107 CFU/ml33 CFU/mL[39]
APTES silanizationT4 bacteriophageEscherichia coli-100 CFU/mL[45]
APTES silanizationAnti-E. coli antibodyEscherichia coli-7 CFU/mL[82]
APTES silanizationDNADNA-4 nM[68]
APTES silanizationDNA aptamerEscherichia coli-10 nM[83]
APTES silanizationGlucose oxidaseAspergillus niger-1000 CFU/mL[84]
GO functionalizationIgGAnti-IgG-7 ng/mL[46]
GO functionalizationGOHemoglobin0–1 mg/mL0.05 mg/mL[85]
GO functionalizationGOHemoglobin0–2 mg/mL0.02 mg/mL[86]
GO functionalizationGOBSA0–2 mg/mL0.043 mg/mL[87]
GO functionalizationGO/polydopamineCo2+ ions1 ppb to 107 ppb0.17 ppb[88]
GO functionalizationGONi2+ ions1 ppb to 107 ppb0.27 ppb[89]
LbL assemblyCHI/PAANaCl0.5–0.8 M36 nm/M[90]
LbL assemblyqP4VPNaCl0.4–0.8 M7 nm/M[91]
LbL assemblyPDDA/TSPPNH3-0.67 ppm[92]
LbL assemblyPDDA/PSS-AuHg2+0.5 ppm–10 ppm0.5 ppm[93]
LbL assemblyPAH-Au:SiO2Streptavidin1.25 Nm–2.7 μM1.25 nM[64]
LbL assemblyPEI/PAApHpH: 2–130.83 dB/pH[94]
LbL assemblyPAH/PAAStaphylococcus aureus-224 CFU/mL[95]
Dip-coating techniqueMoS2/citric acidH2S0–70 ppm0.5 ppm[96]
Dip-coating techniqueGONO0–400 ppm63.65 pm/ppm[97]
In situ crystallizationZIF-8 filmsAcetone6.67 ppm0.015 nm/ppm[98]
Ethanol5.56 ppm0.018 nm/ppm
In situ crystallizationHKUST-1 filmCO2 401 ppm[99]
In situ crystallizationGOx/ ZIF-8Glucose1–8 mM0.5 nm/mM[100]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Cai, J.; Liu, Y.; Shu, X. Long-Period Fiber Grating Sensors for Chemical and Biomedical Applications. Sensors 2023, 23, 542. https://0-doi-org.brum.beds.ac.uk/10.3390/s23010542

AMA Style

Cai J, Liu Y, Shu X. Long-Period Fiber Grating Sensors for Chemical and Biomedical Applications. Sensors. 2023; 23(1):542. https://0-doi-org.brum.beds.ac.uk/10.3390/s23010542

Chicago/Turabian Style

Cai, Jintao, Yulei Liu, and Xuewen Shu. 2023. "Long-Period Fiber Grating Sensors for Chemical and Biomedical Applications" Sensors 23, no. 1: 542. https://0-doi-org.brum.beds.ac.uk/10.3390/s23010542

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop