Next Article in Journal
Performance Evaluation of Sinusoidal Power Supplies for Ozone Generation in Water Purification Applications
Previous Article in Journal
Determination of Partial Propagation Velocity and Partial Isentropic Compressibility Coefficient in Water–Ethanol System
Previous Article in Special Issue
Advanced Image Analytics for Mobile Robot-Based Condition Monitoring in Hazardous Environments: A Comprehensive Thermal Defect Processing Framework
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
This is an early access version, the complete PDF, HTML, and XML versions will be available soon.
Article

Distributed Vibration Monitoring System for 10 kV-400 kVA 3D Wound Core Transformer under Progressive Short-Circuit Impulses

Electrical Power Academy of Sciences, State Grid of Jiangsu Electric Power Co., Ltd., Nanjing 210024, China
*
Author to whom correspondence should be addressed.
Submission received: 15 May 2024 / Revised: 9 June 2024 / Accepted: 19 June 2024 / Published: 21 June 2024

Abstract

As large-scale, high-proportion, and efficient distribution transformers surge into the grids, anti-short circuit capability testing of transformer windings in efficient distribution seems necessary and prominent. To deeply explore the influence of progressively short-circuit shock impulses on the core winding deformation of efficient power transformers, a finite element theoretical model was built by referring to a three-phase three-winding 3D wound core transformer with a model of S20-MRL-400/10-NX2. The distributions of internal equivalent force and total deformation of the 3D wound core transformer along different paths under progressively short-circuit shock impulses varying from 60% to 120% were investigated. Results show that the equivalent stress and total deformation change rate reach their maximum as the short-circuit current increases from 60% to 80%, and the maximum and average variation rate for the equivalent stress reach 177.75% and 177.43%, while the maximum and average variation rate for the total deformation corresponds to 178.30% and 177.45%, respectively. Meanwhile, the maximum equivalent stress and maximum total deformation reach 29.81 MPa and 38.70 μm, respectively, as the applied short-circuit current increased to 120%. In light of the above observations, the optimization and deployment of wireless sensor nodes was suggested. Therefore, a distributed monitoring system was developed for acquiring the vibration status of the windings in a 3D wound core transformer, which is a beneficial supplement to the traditional short-circuit reactance detection methods for an efficient grid access spot-check of distribution transformers.
Keywords: 3D wound core transformer; windings deformation; progressive short-circuit impulse; wireless monitoring system; wireless sensor node 3D wound core transformer; windings deformation; progressive short-circuit impulse; wireless monitoring system; wireless sensor node

Share and Cite

MDPI and ACS Style

Tao, J.; Zhang, S.; Dai, J.; Zhu, J.; Zhao, H. Distributed Vibration Monitoring System for 10 kV-400 kVA 3D Wound Core Transformer under Progressive Short-Circuit Impulses. Sensors 2024, 24, 4062. https://0-doi-org.brum.beds.ac.uk/10.3390/s24134062

AMA Style

Tao J, Zhang S, Dai J, Zhu J, Zhao H. Distributed Vibration Monitoring System for 10 kV-400 kVA 3D Wound Core Transformer under Progressive Short-Circuit Impulses. Sensors. 2024; 24(13):4062. https://0-doi-org.brum.beds.ac.uk/10.3390/s24134062

Chicago/Turabian Style

Tao, Jiagui, Sicong Zhang, Jianzhuo Dai, Jinwei Zhu, and Heng Zhao. 2024. "Distributed Vibration Monitoring System for 10 kV-400 kVA 3D Wound Core Transformer under Progressive Short-Circuit Impulses" Sensors 24, no. 13: 4062. https://0-doi-org.brum.beds.ac.uk/10.3390/s24134062