Article

Development of Antibacterial Ti-Cux Alloys for Dental Applications: Effects of Ageing for Alloys with Up to 10 wt% Cu

1
Division of Applied Materials Science, Department of Engineering Sciences, The Ångström Laboratory, Uppsala University, Box 534, 751 21 Uppsala, Sweden
2
Advanced Materials Division, Mintek, Randburg 2124, South Africa
3
School of Chemical and Metallurgical Engineering, and DST-NRF Centre of Excellence in Strong Materials, hosted by the University of the Witswatersrand, Johannesburg 2000, South Africa
*
Author to whom correspondence should be addressed.
Submission received: 29 October 2019 / Revised: 27 November 2019 / Accepted: 28 November 2019 / Published: 3 December 2019
(This article belongs to the Special Issue Ti-Based Biomaterials: Synthesis, Properties and Applications)

Abstract

:
Peri-implantitis, a disease caused by bacteria, affects dental implants in patients. It is widely treated with antibiotics, however, with growing antibiotic resistance new strategies are required. Titanium-copper alloys are prospective antibacterial biomaterials, with the potential to be a remedy against peri-implantitis and antibiotic resistance. The aim of this study was to investigate Ti-Cux alloys, exploring how Cu content (up to 10 wt%) and ageing affect the material properties. Electron microscopy, X-ray diffraction, hardness testing, bacteriological culture, and electrochemical testing were employed to characterize the materials. It was found that alloys with above 3 wt% Cu had two phases and ageing increased the volume fraction of Ti2Cu. An un-aged alloy of 5 wt% Cu showed what could be Ti3Cu, in addition to the α-Ti phase. The hardness gradually increased with increased Cu additions, while ageing only affected the alloy with 10 wt% Cu (due to changes in microstructure). Ageing resulted in faster passivation of the alloys. After two hours the aged 10 wt% Cu alloy was the only material with an antibacterial effect, while after six hours, bacteria killing occurred in all alloys with above 5 wt% Cu. In conclusion, it was possible to tune the material and antibacterial properties of Ti-Cux alloys by changing the Cu concentration and ageing, which makes further optimization towards an antibacterial material promising.

1. Introduction

Peri-implantitis is a disease caused by bacterial population of an implant surface, which results in local inflammation of soft tissue and ultimately implant loosening and failure [1]. The loss of bone tissue is often associated with the inflammation surrounding the implants, leading to revision surgeries often being troublesome to successfully accomplish [1]. The prevalence of peri-implantitis in the general population is estimated to be between 19% [2] and 28% [3]. Despite the discrepancy in prevalence data, it is generally agreed that the prevalence is under-estimated at present [1,3]. Nevertheless, the importance of the problem is clear and increasing, considering that the dental implant industry is estimated to have reached USD 5 billion in 2018 [1]. The bacteria responsible for the disease include: Peptostreptococcus micros, Porphyromonas ginigivalis and Treponema denticola, among others [4,5]. The fact that these bacteria have virulent characteristic behavior [6], coupled with the increasing problems with antibiotic resistance [7], corroborate that an effective antibacterial solution is needed.
The effectiveness of bacterial colonization lies in the creation of biofilms [8], which have the ability to survive antibiotic treatments due to a multifaceted strategy of slower growth in the biofilm, poor penetration of antibiotics, and genetic variations in the bacteria [9,10]. The gram-positive Staphylococcus epidermidis is a biofilm forming bacteria, and is one of the most common bacteria in implant infections [11], making the bacteria a suitable strain for testing the antibacterial ability of biomaterials.
To date, much research has been focused on various approaches to reduce the bacterial burden correlated to implants, which include: surface treatments [12], the use of photochemical reactions [13], alloying of silver to titanium [14], and recently, the alloying of copper to titanium [15,16,17]. The antibacterial effect of Cu additions was found to be superior compared to silver [18]. The Ag appears to be effectual only at elevated temperatures [19], whereas Cu was found—using in vitro tests—to have antibacterial ability at ambient conditions [20]. For this reason, Cu is being investigated as an antibacterial element with increased frequency in thin films [21,22], ionic form [23,24], and in alloys [17,25,26]. In particular, Zhang et al. [27] have investigated the addition of Cu in titanium and found that there are discrepancies in the literature regarding required copper content and the mechanisms causing bacterial reduction. While success in antibacterial applications has been achieved with copper, the molecular process of bacterial death is not clear. However, it is hypothesized to be caused by Cu ions creating reactive oxygen species (ROS) via the Fenton reaction ( Cu +   +   H 2 O 2     Cu 2 +   +   OH   + · OH ) [24], where ROS plays a role in the prohibition of bacteria 16SrRNA replication, resulting in bacteria death [28].
While it is important to understand the biological interactions in these systems, the antibacterial effect is only one aspect of successfully functioning antibacterial biomaterials. The mechanical properties are also important and should be considered, since implants experience mechanical loading in vivo. When excessive Cu is alloyed to Ti, intermetallic compounds (Ti2Cu [29] and Ti3Cu [30]) form, which can lead to brittleness [31]. While heat treatments of Ti alloys does allow some degree of ductility to be achieved in initially brittle materials, the resultant effect on microstructure and antibacterial properties must be assessed and understood. This inter-relationship between the various choices of compositions and heat treatments, and their impacts on mechanical properties and antibacterial effects, provide an opportunity for optimization of the final alloy. Therefore, the aim of the present study was to investigate these aspects (microstructural, mechanical and antibacterial) for different Ti-Cu alloys, to contribute to the understanding of these materials, and facilitate their future use as antibacterial biomaterials. The investigation only focused on alloys in the range 0 to 10 wt% Cu, since Cu ions released in this range of alloys did not show notable toxicity effects in previous works [15,23].

2. Materials and Methods

2.1. Production and Preparation of Alloys

Alloys of titanium and copper were produced in a range from 0 to 10 wt% Cu (Table 1). Titanium grade 4 (Sandvik AB, Stockholm, Sweden), “CPTi”, and 99.9999% pure copper rods (365327-21.5G, Sigma Aldrich, St. Louis, MO, USA) were used to produce the alloy mixtures. Alloys were re-melted five times in an arc furnace, then re-melted and cast into rods in the same furnace (Series 5 Bell Jar, Centorr Vacuum industries, Nashua, New Hampshire, USA). Partial homogenization was achieved by turning over the melted alloys between each of the five melting events. Complete homogenization was achieved by heat treatments of the rods at 900 °C for 18 h, then 798 °C for 24 h and then finally, for half of the produced alloys, ageing at 400 °C for six hours. The annealing was done in vacuumed ampoules to reduce the oxygen contamination in the alloys, at a pressure of 1.333 mbar. All alloys were quenched into salt brine water by breaking the ampoules, to allow faster cooling. The alloy samples were cut into slices for analysis using a silicon carbide disk (150s, Struers, Ballerup, Denmark), to minimize cutting damage. Following sectioning, the samples were embedded in Bakelite resin (PolyFast, Stuers, Ballerup, Denmark) for metallographic preparation.
The metallographic preparation of the samples included grinding and polishing for subsequent microstructural studies. The three-step metallographic procedure developed by Vander Voort [32] was adapted for the present study, further details are given in Table 2.

2.2. Microstructural Studies

The microstructures of the materials were studied by scanning electron microscopy (SEM)—using a LEO1550 SEM (ZEISS group, Oberkochen, Germany) equipped with an INCA AZtec Energy Dispersive X-ray Spectroscopy (EDX) system (Oxford Instruments, High Wycombe, UK). Images were taken with an Everhart-Thornley (HE-SE2 detector, ZEISS group, Oberkochen, Germany) and backscattered electron detector (BSD). To ensure that the microstructure was discernible in the SEM, the samples were etched in Kroll’s Etchant: 2 mL HF, 4 mL HNO3 and 100 mL distilled water, with etching times of 30 s using cotton swabbing [33].
The energy dispersive x-ray spectroscopy (EDX) analysis of the 5Cu798 sample was performed on a Merlin SEM (ZEISS group, Oberkochen, Germany) equipped with an Ultim-Max 100 mm2 Silicon Drift Detector (Oxford Instruments, High Wycombe, UK) at a voltage of 15 kV and 8.5 mm working distance.

2.3. Hardness Studies

The hardness of the Ti-Cux alloys was measured using a Vickers Hardness tester (Duravision EMCO, Prufmaschinen GmbH, Kuchl, Austria) with a 9.8 centinewton load. The machine was calibrated before testing with a standard Vickers sample, and an average was taken from three indentations.

2.4. Phase Identification

All samples studied by X-ray diffraction were polished as specified by Vander Voort [32] (Table 2). X-ray diffraction (XRD) was performed on a D8 Advance TWIN-TWIN diffractometer (Bruker, AXS GmbH, Karlsruhe, Germany) with Cu Kα radiation (Kα1 = 1.540598 Å with a Ni filter) and using the Bragg-Bretano experimental set-up. The detector system was a LynxEye XE PSD detector (Bruker, AXS GmbH, Karlsruhe, Germany). The EVA software suite (2015, Bruker) was used for phase analysis, while diffractogram plotting was done in Origin (2018b, OriginLab Corp., Northhampton, MA, USA). All crystallographic data were retrieved from the ICDD database PDF–4 + 2019 [34] and included PDF# 00-044-1294 (HCP-Ti), PDF# 00-015-0717 (Ti2Cu) [35] and PDF# 00-055-0296 (Ti3Cu).

2.5. Bacterial Luminescence by Direct Contact Test

The bacteria direct contact test has already been described [17], so only a summary is provided here. Staphylococcus epidermidis (XEN43) is a genetically modified bacterial strain that is bioluminescent due to the luxABCDE gene being bio-engineered into the bacterial genome [36,37]. Overnight bacterial inoculum of XEN43 was prepared a priori then seeded on the surface of sterile 5 mm diameter Ti-Cux alloys (both aged and un-aged) and allowed to attach. Tryptic soy broth (TSB, Fluke-Sigma Aldrich, Stockholm, Sweden) was then carefully added to the test wells. Periodic measurements of luminescence were recorded for the samples on a Hidex plate CHAMELEON V (425-106, Multilabel counter, Turku, Finland), and the mean was used to determine the antibacterial rate (R) after two- and six-hours of exposure, using Equation 2 [38]:
R =   N c o n t r o l N s a m p l e N c o n t r o l ×   100 %
where Ncontrol = mean luminescence from the CPTi sample, and Nsample = mean luminescence for the Ti-Cux alloys [38].

2.6. Corrosion Testing

The corrosion testing was performed on all the samples at 37 ± 1 °C in a phosphate buffered saline (PBS) solution (containing 8 g/L sodium chloride, 0.2 g/L potassium chloride, 1.44 g/L sodium hydrogen phosphate, and 0.24 g/L potassium di-hydrogen phosphate) maintained at a pH of 7.4.
The sample preparation for the corrosion studies included mounting the samples (CPTi and Ti–Cux) of approximately 1 cm2 in area, in non-conductive epoxy resin with a copper wire soldered to the samples for electrical connection. The samples were ground to 120 grit surface finishes using a SiC paper, then rinsed with de-mineralized water and degreased in acetone.
The electro-chemical testing was performed using a computer-driven Potentiostat (AutoTafel, ACM Instruments, Cark, Cumbria, England). Two graphite rods acted as counter-electrodes and a Haber-Luggin capillary made the junction with a saturated calomel reference electrode (SCE). All potential values were with respect to the SCE. Nitrogen was bubbled continuously during testing in order to remove all the oxygen and maintain an anaerobic condition.
After each sample was immersed in the solution, the open circuit potential against time curve was recorded for up to 4 h to determine the open-circuit potential (OCP). When the potential had reached a sufficiently stable value at four hours, a cyclic polarization scan was recorded from −250 mV to 1500 mV versus the corrosion potential at a scanning speed of 10 mV/min. The scan direction was not reversed.

2.7. Statistical Analysis

The statistical analysis for the bacterial luminescence measurements was done in Origin software (2018b, OriginLab Corp., Northhampton, MA, USA) at two and six hours, using a One-way ANOVA with a Tukey HSD Post-Hoc test, and with Levene’s homogeneity of variance test. The same statistical test was also performed for the hardness with the exception that a Brown-Forsythe test for homogeneity of variance was performed. All tests had a statistical significance setting of p = 0.05.

3. Results

3.1. Microstructural Studies

Microstructures for the alloys were compared to determine any differences due to ageing. The microstructures of the alloys (both aged and un-aged) with less than 3 wt% Cu had a single-phase structure of α-Ti (the hcp solid solution of titanium) (Figure 1). However, the 1Cu798 showed peaks for the 2θ diffraction angle of the Ti3Cu phase, at 20.9° and 23.4° (Figure 2). Those with equal to and greater than 3 wt% Cu were all two-phased: Ti2Cu and α-Ti (Figure 1). X-ray diffraction studies confirmed these findings (Figure 2), where HCP-Ti and Ti2Cu peaks were identified, but peaks for the Ti3Cu crystals were also observed at the 2θ diffraction angles of 20.9° and 23.4° for the alloys: 1Cu798, 3Cu798, 5Cu798, and 3Cu400.
Comparison of the 10 wt% Cu before and after ageing displayed that a larger volume fraction of Ti2Cu precipitated due to this heat treatment. While an increase in Ti2Cu with ageing was also found for the 5 and 3 wt% Cu, the volume fraction of precipitated Ti2Cu was lower. In addition, these alloys had lamellar microstructures of Ti2Cu and α-Ti (Figure 1).

3.2. EDX Study of Precipitates

Precipitates in the 5Cu798 sample were studied to determine the presence of variations in the Cu content for the individual phases in the alloy. Since it is known that the Ti2Cu and Ti3Cu crystals have an atomic % Cu concentration of 33% and 25%, respectively [29,30], point analysis of individual crystals was performed to ascertain which phase was present. For sample area 1 (Figure 3a), the atomic concentrations for precipitates 1 and 2 were 33.2 ± 1.1 and 34.1 ± 0.3, respectively (Table 3). For sample area 2 (Figure 3b), the atomic concentrations for precipitates 3 and 4 were 31.5 ± 2.6 and 24.6 ± 0.5, respectively (Table 3).

3.3. Bacterial Luminescence

At two hours, no significance in luminescence was found among the samples, except between CPTi-798 and the 1Cu400 and 3Cu400 samples, which had significantly higher values (Figure 4). However, the antibacterial rate of 10Cu400 (R = 12%) was higher than the other aged alloys at this time point. All other alloys had a negative R at this time point, indicating that more bacteria were found on these alloys than on the respective control.
For the un-aged alloys, it was found that after six-hours of exposure (Figure 5) the R for 10Cu798 (42%) was higher than that for 5Cu798 (7%). The alloys with lower Cu content still had negative R-values. The 10Cu798 alloy also had significantly lower luminescence than alloys 1Cu798, 3Cu798 and 1Cu400 (p < 0.022). At this time point, the 10Cu400 had lower luminescence than the samples CPTi-798, 1Cu798, 1Cu400, 3Cu798, and 3Cu400 (p < 0.036). Within the aged alloys, it was found that R for 10Cu400 (45%) was greater than that for the 5Cu400 (15%). As for the un-aged alloys, the 3Cu400 and 1Cu400 had negative R-values.

3.4. Hardness Tests

The effects of alloying Cu to Ti and ageing on hardness were investigated (Figure 6). The 10Cu798 alloy had the highest hardness (350 ± 12 Hv) of the alloys while the CPTi-400 alloy had the lowest (120 ± 3 HV). The increased Cu addition to the CPTi correlated with a gradual augmentation in the Vicker’s hardness, except for the 10Cu798 alloy with a hardness twice that of the 5Cu798 alloy (171 ± 7 HV, p < 0.0001 in comparison with all other alloys). Ageing did not significantly affect the hardness of the alloys, except for 10Cu798, which was 1.9 times (p < 0.0001) harder than 10Cu400 (182 ± 1 HV), and CPTi798 which had a 14% (p < 0.021) increase in HV after ageing.

3.5. Corrosion Tests

Corrosion studies were performed to determine the effect of the copper additions on the corrosion resistance, as well as the effect of ageing. The alloys were plotted in a single graph (Figure 7). The alloys aged at 400 °C showed a distinct corrosion profile after the anodic reaction took place. The aged alloys tended to passivate rapidly after the anodic reaction commenced. The un-aged alloys (quenched from 798 °C) clearly had a different corrosion profile trend, which indicated a gradual change in the passivation after the anodic reaction.

4. Discussion

The present investigation focused on alloying up to 10 wt% of Cu into commercially pure titanium (a well-known implant material), where Cu has shown antibacterial potential in previous studies [17,20,38,39]. Its purpose was to determine the resultant microstructural and antibacterial characteristics of the materials, as a function of Cu addition and ageing heat treatments.
Microstructural and X-ray diffraction observations indicated no β-Ti in any of the alloys, despite a rapid quench (Figure 2). The reasons for this could be the active eutectoid transformation kinetics that drive transformation from β     Ti     α     Ti   +   Ti 2 Cu [40]. The two phases of α-Ti (HCP-Ti) and Ti2Cu were observed as predicted in phase calculations [17]. The CPTi and 1Cu–except the 1Cu798 alloy that could have Ti3Cu present−alloys were single-phase α-Ti alloys (Figure 1 and Figure 2), while in alloys with higher Cu content (aged and un-aged) both α-Ti and Ti2Cu were found. The ageing had a major effect on the microstructure and the Ti2Cu precipitates had a larger volume fraction in the aged alloys. The ageing of the 10Cu798 alloy coarsened the Ti2Cu from small precipitates to larger lamellar microstructures (Figure 1). A similar change occurred with ageing in the other two-phased alloys (5Cu798 and 3Cu798), but with coarsening of uniform lamellae of Ti2Cu in the α-Ti phase.
α-Ti and Ti2Cu were observed by X-ray diffraction, in addition to Ti3Cu at 2θ angles of 20.9° and 23.4° for the 1Cu798, 3Cu798, 3Cu400, and 5Cu798 alloys. EDX measurements on a 5Cu798 sample confirmed that some of the precipitates had the expected 33 at% Cu for Ti2Cu [35], while at least one precipitate had compositions closer to 25 at% Cu, which is the expected composition for Ti3Cu [30]. However, the results might have been affected by analyzing small areas, which resulted in collecting the signal from the surrounding phases. Although this study did not make use of a standard reference material for the analysis, the results gave insight into the variation of composition for the precipitates with Cu in the Ti-Cux alloys. It should however be noted that the precipitates with compositions closer to Ti3Cu were in lower volume fractions—for the 5Cu798 alloy—relative to the precipitates with compositions close to 33 at% Cu. This lower volume fraction could be the reason for the absence of Ti3Cu by X-ray diffraction in the 10 wt% Cu alloys, since it could have been below the detection limit for the technique. However, this was only a preliminary study on one alloy and further studies are needed to confirm the general presence of Ti3Cu in Ti-Cux alloys.
As well as the microstructure, the hardness was also affected by Cu additions and ageing, and the 10Cu798 was twice as hard as the 10Cu400 alloy. The mechanism causing this could be the coarser lamellar structure in the 10Cu400 [41]. Ageing had a hardening effect on the CPTi-798 alloy as well, because the hardness was significantly higher for the CPTi-400 alloy.
The bacteria test gave an interesting result after two hours of exposure for the alloys, and 10Cu400 had an antibacterial rate R of 11%, while all the other Ti-Cux alloys had higher mean luminescence than CPTi. The reason for the higher luminescence could be that the bacteria underwent a stress response, which caused a rapid increase in population [23]. Comparison of the aged alloys at two hours and at six hours gave a similar trend for antibacterial rate (R). The 10Cu400 alloys seemed to be effectual at bacteria reduction already from two hours and thereafter increased, and at six hours the R was 46%. The 5Cu798 and 5Cu400 alloys after six hours had R values of 7% and 15%, respectively, although this was not significantly different from alloys with lower Cu content. The greater R at six hours for both aged (45%) and un-aged (42%) 10 wt% Cu alloys agreed with previous findings where a higher Cu content has been reported to yield a stronger antibacterial material [17,38]. The difference in R for the 10 wt% Cu alloys at two hours could be due to the larger amounts of Ti2Cu in the aged alloy leading to higher Cu ion release rates as has been observed in studies on Ti-6Al-4V-5Cu alloys [28]. However, further studies on ion release from Ti-Cux are needed to support this conclusion. Additionally, direct contact of bacteria with a Cu rich surface—such as the 10Cu400 with higher volume fraction Ti2Cu—could also have played a role in the antibacterial effect [24]. Thus, Cu ions and direct contact killing contributed to the antibacterial effect, and future studies could investigate how the amount and size of the Ti2Cu phase influences copper ion release and the contact killing of bacteria.
The corrosion results indicated that alloying with Cu and ageing affected the corrosion rates and passivation rates. Alloying and ageing induced faster passivation for higher Cu contents, and decreased the corrosion rates. These results are in agreement with the findings of Zhang et al. [38] for an aged 4 wt% Cu alloy.
A limitation to the present study is that only alloys in the range of 0 to 10 wt% Cu were investigated. It has been demonstrated that a higher Cu content yields a better antibacterial response [17], however, an excess of copper can be harmful to the human body [42]. Previous studies [15,23] have reported that the Cu ions released from alloys with up to 10 wt% Cu did not have any notable toxic effects and were therefore the focus of the present study. Moreover, only two heat treatments were studied due to a necessary delimitation of the study. There are other heat treatments that could be tested, and future studies should further optimize the alloying process. The investigation on the presence of Ti3Cu was a preliminary study and the results should not be viewed as conclusive due to only one alloy being characterized, the low number of precipitates characterized and the low resolution of the EDX technique. Another limitation is that the antibacterial ability of the alloys was only tested with one type of bacteria. However, the bacterium used, Staphylococcus epidermidis, is one of the most prevalent bacteria in implant infections and its use additionally allowed comparison with previous studies [23].

5. Conclusions

Both Ti2Cu and Ti3Cu were detected in Cu alloys using X-ray diffraction. A preliminary EDX study on the un-aged 5 wt% Cu alloy also indicated the presence of Ti3Cu, however with the Ti2Cu in majority. While the study of the Ti3Cu was not quantitative in this investigation, it is recommended that future works focus on determination of this phase.
The hardness was reduced after ageing of the 10Cu798 alloy, as the microstructure changed from small precipitates to coarser lamellar microstructures. The alloys had good antibacterial rates above 5 wt% Cu (aged and un-aged) after six-hours of exposure, and the two-hour exposure was probably too short a duration for bacterial reduction to occur in most of the alloys. Ageing the alloys only ensured faster antibacterial rates after 2 hours, when the concentration of Cu was greater than 10 wt% Cu. The addition of Cu to Ti and ageing increased the corrosion resistance of the alloys, which could protect the biomaterial in vivo. However, since the ageing also lowered the hardness of the higher Cu content alloys, care should be taken to avoid over-ageing, and hence softening.
In conclusion, the un-aged 10 wt% Cu alloy was considered a suitable candidate material, which provided a good antibacterial effect, with superior hardness and corrosion protection. The ideal composition and heat treatment of these materials will however depend on the specific application envisioned, and will require further optimization.

Author Contributions

Conceptualization, H.E., S.N. and C.Ö.-M; Formal analysis, L.F., N.M., S.N. and C.Ö.-M; Funding acquisition, L.A.C., L.H.C., S.N. and C.Ö.-M; Investigation, L.F. and N.M.; Methodology, S.N. and C.Ö.-M; Project Administration, L.A.C., L.H.C., H.E., S.N. and C.Ö.-M; Resources, L.A.C., H.E., S.N. and C.Ö.-M; Supervision, L.A.C., L.H.C., H.E., S.N. and C.Ö.-M; Validation, L.F. and N.M.; Visualization, L.F. and N.M.; Writing-original draft, L.F.; Writing-review & editing, L.F., N.M., L.A.C., L.H.C., H.E., S.N. and C.Ö.-M.

Funding

This research was funded by the South African-Sweden Bilateral Scientific Research Cooperation program funded by the Swedish Foundation for International Cooperation in Research and Higher Education (STINT, GA SA2017-7127) and the South African National Research Foundation (NRF funding through STNT170905261815).

Acknowledgments

The authors thank Victoria Sternhagen for help with SEM imaging.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Alani, A.; Kelleher, M.; Bishop, K. Peri-implantitis. Part 1: Scope of the problem. Br. Dent. J. 2014, 217, 281–287. [Google Scholar] [CrossRef] [PubMed]
  2. Atieh, M.A.; Alsabeeha, N.H.M.; Faggion, C.M.; Duncan, W.J. The frequency of peri-implant diseases: A systematic review and meta-analysis. J. Periodontol. 2013, 84, 1586–1598. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  3. Fransson, C.; Lekholm, U.; Jemt, T.; Berglundh, T. Prevalence of subjects with progressive bone loss at implants. Clin. Oral Impl. Res. 2005, 16, 440–446. [Google Scholar] [CrossRef] [PubMed]
  4. Norowski, P.A.; Bumgardner, J.D. Biomaterial and antibiotic strategies for peri-implantitis: A review. J. Biomed. Mater. Res. 2009, 88B, 530–543. [Google Scholar] [CrossRef]
  5. Hultin, M.; Gustafson, A.; Hallström, H.; Johansson, L.-Å.; Ekfeldt, A.; Klinge, B. Microbiological findings and host response in patients with peri-implantitis. Clin. Oral Impl. Res. 2002, 13, 349–358. [Google Scholar] [CrossRef] [PubMed]
  6. Ladomersky, E.; Petris, M.J. Copper tolerance and virulence in bacteria. Metallomics 2015, 7, 957–964. [Google Scholar] [CrossRef] [Green Version]
  7. Hawkey, P.M. The growing burden of antimicrobial resistance. J. Antimicrob. Chemother. 2008, 62, i1–i9. [Google Scholar] [CrossRef]
  8. Arciola, C.R.; Campoccia, D.; Speziale, P.; Montanaro, L.; Costerton, J.W. Biofilm formation in Staphylococcus implant infections. A review of molecular mechanisms and implications for biofilm-resistant materials. Biomaterials 2012, 33, 5967–5982. [Google Scholar] [CrossRef]
  9. Stewart, P.S. Mechanisms of antibiotic resistance in bacterial biofilms. Int. J. Med. Microbiol. 2002, 292, 107–113. [Google Scholar] [CrossRef]
  10. Vasudevan, S.; Joseph, H.A.; Swamy, S.S.; Solomon, A.P. Antibiotic Resistance in Biofilms; ACS Symposium Series; Rathinam, N.K., Sani, R.K., Eds.; American Chemical Society: Washington, DC, USA, 2019; pp. 205–224. [Google Scholar] [CrossRef]
  11. Zhang, Y.-Q.; Ren, S.-X.; Li, H.-L.; Wang, Y.-X.; Fu, G.; Yang, J.; Qin, Z.-Q.; Miao, Y.-G.; Wang, W.-Y.; Chen, R.-S.; et al. Genome-based analysis of virulence genes in a non-biofilm-forming Staphylococcus epidermidis strain (ATCC 12228). Mol. Microbiol. 2003, 49, 1577–1593. [Google Scholar] [CrossRef] [Green Version]
  12. Spriano, S.; Bosetti, M.; Bronzoni, M.; Vernè, E.; Maina, G.; Bergo, V.; Cannas, M. Surface properties and cell response of low metal ion release Ti-6Al-7Nb alloy after multi-step chemical and thermal treatments. Biomaterials 2005, 26, 1219–1229. [Google Scholar] [CrossRef]
  13. Unosson, E.; Tsekoura, E.K.; Engqvist, H.; Welch, K. Synergetic inactivation of Staphylococcus epidermidis and Streptococcus mutans in a TiO2/H2O2/UV system. Biomatterials 2013, 3, e26727. [Google Scholar] [CrossRef] [Green Version]
  14. Unosson, E.; Morgenstern, M.; Engqvist, H.; Welch, K. In vitro antibacterial properties and UV induced response from Staphylococcus epidermidis on Ag/Ti oxide thin films. J. Mater. Sci. Mater. Med. 2016, 27, 49. [Google Scholar] [CrossRef]
  15. Bai, B.; Zhang, E.; Dong, H.; Liu, J. Biocompatibility of antibacterial Ti–Cu sintered alloy: In vivo bone response. J. Mater. Sci. Mater. Med. 2015, 26, 265. [Google Scholar] [CrossRef]
  16. Zhang, E.; Li, F.; Wang, H.; Liu, J.; Wang, C.; Li, M.; Yang, K. A new antibacterial titanium–copper sintered alloy: Preparation and antibacterial property. Mater. Sci. Eng. C. 2013, 33, 4280–4287. [Google Scholar] [CrossRef]
  17. Fowler, L.; Janson, O.; Engqvist, H.; Norgren, S.; Öhman-Mägi, C. Antibacterial investigation of titanium-copper alloys using luminescent Staphylococcus epidermidis in a direct contact test. Mater. Sci. Eng. C. 2019, 97, 707–714. [Google Scholar] [CrossRef]
  18. Codiţă, I.; Caplan, D.M.; Drăgulescu, E.-C.; Lixandru, B.-E.; Coldea, I.L.; Dragomirescu, C.C.; Surdu-Bob, C.; Bădulescu, M. Antimicrobial activity of copper and silver nanofilms on nosocomial bacterial species. Roum. Arch. Microbiol. Immunol. 2010, 69, 204–212. [Google Scholar]
  19. Russel, A.D.; Hugo, W.B. 7 Antimicrobial activity and action of silver. Progr. Med. Chem. 1994, 31, 351–370. [Google Scholar] [CrossRef]
  20. Michels, H.T.; Noyce, J.O.; Keevil, C.W. Effects of temperature and humidity on the efficacy of methicillin-resistant Staphylococcus aureus challenged antimicrobial materials containing silver and copper. Lett. Appl. Microbiol. 2009, 49, 191–195. [Google Scholar] [CrossRef] [Green Version]
  21. Stranak, V.; Wulff, H.; Rebl, H.; Zietz, C.; Arndt, K.; Bogdanowicz, R.; Nebe, B.; Bader, R.; Podbielski, A.; Hubicka, Z.; et al. Deposition of thin titanium–copper films with antimicrobial effect by advanced magnetron sputtering methods. Mater. Sci. Eng. C 2011, 31, 1512–1519. [Google Scholar] [CrossRef]
  22. Jäger, E.; Schmidt, J.; Pfuch, A.; Spange, S.; Beier, O.; Jäger, N.; Jantschner, O.; Daniel, R.; Mitterer, C. Antibacterial silicon oxide thin films doped with zinc and copper grown by atmospheric pressure plasma chemical vapor deposition. Nanomaterials 2019, 9, 255. [Google Scholar] [CrossRef] [Green Version]
  23. Fowler, L.; Engqvist, H.; Öhman-Mägi, C. Effect of Cu ion concentration on bacteria and cells. Materials 2019, 12, 3798. [Google Scholar] [CrossRef] [Green Version]
  24. Mathews, S.; Hans, M.; Mücklich, F.; Solioz, M. Contact killing of bacteria on copper is suppressed if bacterial-metal contact is prevented and is induced on iron by copper ions. Appl. Environ. Microbiol. 2013, 79, 2605–2611. [Google Scholar] [CrossRef] [Green Version]
  25. Ke, Z.; Yi, C.; Zhang, L.; He, Z.; Tan, J.; Jiang, Y. Characterization of a new Ti-13Nb-13Zr-10Cu alloy with enhanced antibacterial activity for biomedical applications. Mater. Lett. 2019, 253, 335–338. [Google Scholar] [CrossRef]
  26. Liu, C.; Zhang, E. Biocorrosion properties of antibacterial Ti–10Cu sintered alloy in several simulated biological solutions. J. Mater. Sci. Mater. Med. 2015, 26, 142. [Google Scholar] [CrossRef]
  27. Zhang, E.-L.; Fu, S.; Wang, R.-X.; Li, H.-X.; Liu, Y.; Ma, Z.-Q.; Liu, G.-K.; Zhu, C.-S.; Qin, G.-W.; Chen, D.-F. Role of Cu element in biomedical metal alloy design. Rare Met. 2019, 38, 476–494. [Google Scholar] [CrossRef]
  28. Li, M.; Ma, Z.; Zhu, Y.; Xia, H.; Yao, M.; Chu, X.; Wang, X.; Yang, K.; Yang, M.; Zhang, Y.; et al. Toward a molecular understanding of the antibacterial mechanism of copper-bearing titanium alloys against staphylococcus aureus. Adv. Healthc. Mater. 2016, 5, 557–566. [Google Scholar] [CrossRef] [Green Version]
  29. Kumar, K.C.H.; Ansara, I.; Wollants, P.; Delaey, L. Thermodynamic optimisation of the Cu-Ti system. Zeitschrift Für Metallkunde 1996, 87, 666–672. [Google Scholar]
  30. Canale, P.; Servant, C. Thermodynamic assessment of the Cu–Ti system taking into account the new stable phase CuTi3. MEKU 2002, 93, 273–276. [Google Scholar] [CrossRef]
  31. Appel, F.; Oehring, M. γ-titanium aluminide alloys: Alloy design and properties. In Titanium and Titanium Alloys, 1st ed.; Leyens, C., Peters, M., Eds.; Wiley-VCH Verlag GmbH & Co. KGaA: Weinheim, Germany, 2003; pp. 89–152. [Google Scholar] [CrossRef]
  32. Voort, G.V. Materials characterization & testing: Microstructure of titanium and its alloys. Ind. Heat. 2006, 73, 82–84. [Google Scholar]
  33. Nadai, L.; Katona, B.; Terdik, A.; Bognar, E. Chemical etching of titanium samples. Periodica Polytechnica Mech. Eng. 2013, 57, 57. [Google Scholar] [CrossRef] [Green Version]
  34. PDF-4+ 2019, ICDD. (n.d.). Available online: http://www.icdd.com/index.php/pdf-4/ (accessed on 10 May 2019).
  35. Mueller, M.H.; Knott, H.W. The crystal structures of Ti2 Cu, Ti2 Ni, Ti4 Ni2 O, and Ti4 Cu2 O. Trans. Metallurg. Soc. AIME 1963, 227, 674–678. [Google Scholar]
  36. Vuong, C.; Kocianova, S.; Yu, J.; Kadurugamuwa, J.L.; Otto, M. Development of real-time in vivo imaging of device-related staphylococcus epidermidis infection in mice and influence of animal immune status on susceptibility to infection. J. Infect. Dis. 2008, 198, 258–261. [Google Scholar] [CrossRef] [Green Version]
  37. Wiedmer, D.; Petersen, F.C.; Lönn-Stensrud, J.; Tiainen, H. Antibacterial effect of hydrogen peroxide-titanium dioxide suspensions in the decontamination of rough titanium surfaces. Biofouling 2017, 33, 451–459. [Google Scholar] [CrossRef] [Green Version]
  38. Zhang, E.; Ren, J.; Li, S.; Yang, L.; Qin, G. Optimization of mechanical properties, biocorrosion properties and antibacterial properties of as-cast Ti–Cu alloys. Biomed. Mater. 2016, 11, 065001. [Google Scholar] [CrossRef]
  39. Bai, B.; Zhang, E.; Liu, J.; Zhu, J. The anti-bacterial activity of titanium-copper sintered alloy against Porphyromonas gingivalis in vitro. Dent. Mater. J. 2016, 35, 659–667. [Google Scholar] [CrossRef] [Green Version]
  40. Donthula, H.; Vishwanadh, B.; Alam, T.; Borkar, T.; Contieri, R.J.; Caram, R.; Banerjee, R.; Tewari, R.; Dey, G.K.; Banerjee, S. Morphological evolution of transformation products and eutectoid transformation(s) in a hyper-eutectoid Ti-12 at% Cu alloy. Acta Mater. 2019, 168, 63–75. [Google Scholar] [CrossRef]
  41. Soffa, W.A.; Laughlin, D.E. High-strength age hardening copper–titanium alloys: Redivivus. Progr. Mater. Sci. 2004, 49, 347–366. [Google Scholar] [CrossRef]
  42. Bull, P.C.; Thomas, G.R.; Rommens, J.M.; Forbes, J.R.; Cox, D.W. The Wilson disease gene is a putative copper transporting P–type ATPase similar to the Menkes gene. Nat. Genet. 1993, 5, 327–337. [Google Scholar] [CrossRef]
Figure 1. Secondary electron images of: (a) CPTi-798, (b) CPTi-400, and backscattered electron images of: (c) 1Cu798, (d) 1Cu400, (e) 3Cu798, (f) 3Cu400, (g) 5Cu798, (h) 5Cu400, (i) 10Cu798, and (j) 10Cu400.
Figure 1. Secondary electron images of: (a) CPTi-798, (b) CPTi-400, and backscattered electron images of: (c) 1Cu798, (d) 1Cu400, (e) 3Cu798, (f) 3Cu400, (g) 5Cu798, (h) 5Cu400, (i) 10Cu798, and (j) 10Cu400.
Materials 12 04017 g001
Figure 2. X-ray diffraction patterns of Ti-Cux alloys heat-treated at 798 °C, some aged at 400 °C: blue triangles indicate HCP-Ti, red triangles indicate Ti2Cu and green triangles indicate Ti3Cu. Note the peaks for Ti3Cu at 20.9° and 23.4°.
Figure 2. X-ray diffraction patterns of Ti-Cux alloys heat-treated at 798 °C, some aged at 400 °C: blue triangles indicate HCP-Ti, red triangles indicate Ti2Cu and green triangles indicate Ti3Cu. Note the peaks for Ti3Cu at 20.9° and 23.4°.
Materials 12 04017 g002
Figure 3. Positions of EDX spectral analyses of sample 5Cu798: (a) Sample area 1 with precipitate 1 (48, 49, 50) and precipitate 2 (51, 52, 53, 54, 55). (b) Sample area 2 with precipitate 3 (65, 66, 67) and precipitate 4 (68, 79, 80).
Figure 3. Positions of EDX spectral analyses of sample 5Cu798: (a) Sample area 1 with precipitate 1 (48, 49, 50) and precipitate 2 (51, 52, 53, 54, 55). (b) Sample area 2 with precipitate 3 (65, 66, 67) and precipitate 4 (68, 79, 80).
Materials 12 04017 g003
Figure 4. Mean luminescence counts (bars for standard deviation) of XEN 43 bacteria after two hours for all alloys, the negative controls were (CPTi), and the corresponding antibacterial rates are shown in black. Levene’s Test: F (9,20) = 1.83, p = 0.123. One-way Anova: F = 3.176 (p = 0.015) with Tukey Test. Note: The same letters (e.g, “A” compared to “A”) denotes being non-significantly different, while different letters (e.g. “A” compared to “B”) denotes being statistically significantly different.
Figure 4. Mean luminescence counts (bars for standard deviation) of XEN 43 bacteria after two hours for all alloys, the negative controls were (CPTi), and the corresponding antibacterial rates are shown in black. Levene’s Test: F (9,20) = 1.83, p = 0.123. One-way Anova: F = 3.176 (p = 0.015) with Tukey Test. Note: The same letters (e.g, “A” compared to “A”) denotes being non-significantly different, while different letters (e.g. “A” compared to “B”) denotes being statistically significantly different.
Materials 12 04017 g004
Figure 5. Mean luminescence counts (bars for standard deviation) of XEN 43 bacteria after six hours for all alloys, the negatives controls were CPTi, and the corresponding antibacterial rates are shown in black. Levene’s Test: F (9,20) = 2.21, p = 0.066. One-way Anova: F = 5.697 (p < 0.001) with Tukey Test. Note: The same letters (e.g, “A” compared to “A”) denotes being non-significantly different, while different letters (e.g. “A” compared to “B”) denotes being statistically significantly different.
Figure 5. Mean luminescence counts (bars for standard deviation) of XEN 43 bacteria after six hours for all alloys, the negatives controls were CPTi, and the corresponding antibacterial rates are shown in black. Levene’s Test: F (9,20) = 2.21, p = 0.066. One-way Anova: F = 5.697 (p < 0.001) with Tukey Test. Note: The same letters (e.g, “A” compared to “A”) denotes being non-significantly different, while different letters (e.g. “A” compared to “B”) denotes being statistically significantly different.
Materials 12 04017 g005
Figure 6. Mean Vickers hardness (bars for standard deviation) of all samples. Brown-Forsythe: F (9,20) = 1.413, p = 0.2476. One-way Anova: F = 368.92 (p < 0.001) with Tukey test. Note: The same letters (e.g, “A” compared to “A”) denotes being non-significantly different, while different letters (e.g. “A” compared to “B”) denotes being statistically significantly different.
Figure 6. Mean Vickers hardness (bars for standard deviation) of all samples. Brown-Forsythe: F (9,20) = 1.413, p = 0.2476. One-way Anova: F = 368.92 (p < 0.001) with Tukey test. Note: The same letters (e.g, “A” compared to “A”) denotes being non-significantly different, while different letters (e.g. “A” compared to “B”) denotes being statistically significantly different.
Materials 12 04017 g006
Figure 7. Corrosion plots for the aged (at 400 °C) and un-aged (quenched from 798 °C) alloys. The aged alloys are indicated with triangles to indicate the profile. Note: the 10Cu798 alloy was not included in the corrosion study.
Figure 7. Corrosion plots for the aged (at 400 °C) and un-aged (quenched from 798 °C) alloys. The aged alloys are indicated with triangles to indicate the profile. Note: the 10Cu798 alloy was not included in the corrosion study.
Materials 12 04017 g007
Table 1. Ti-Cux samples used in the study.
Table 1. Ti-Cux samples used in the study.
Nominal wt% CuCPTi1 wt% Cu3 wt% Cu5 wt% Cu10 wt% Cu
Alloys heat treated at 798 °C (un-aged)CPTi-7981Cu7983Cu7985Cu79810Cu798
Alloys aged at 400 °CCPTi-4001Cu4003Cu4005Cu40010Cu400
Table 2. Three-step metallographic preparation of Ti-Cu (All products sourced from Struers, except H2O2 sourced from BASF SE, Ludwigshafen, Germany).
Table 2. Three-step metallographic preparation of Ti-Cu (All products sourced from Struers, except H2O2 sourced from BASF SE, Ludwigshafen, Germany).
Steps1–Grind2–Rough Polish3–Final Polish
Surface SiC–320P MD–Dur cloth MD–Floc cloth
Abrasive-6 µm diamond suspension OP-S Si-Colloids and H2O2 (5:1) solution
LubricantWaterDP Lubricant Red -
Speed (rpm)200 contra150 contra150 contra
Duration (min)Until planar15 min15 min
Table 3. EDX point spectral analyses of sample areas 1 and 2 (point spectral analysis correspond to points in Figure 3).
Table 3. EDX point spectral analyses of sample areas 1 and 2 (point spectral analysis correspond to points in Figure 3).
Precipitate (EDX Point Analyzed)Atomic % Copper
(Balance % Titanium)
Possible Phases
Precipitate 1 (48, 49, 50)33.2 ± 1.1Ti2Cu
Precipitate 2 (51, 52, 53, 54, 55)34.1 ± 0.3Ti2Cu
Precipitate 3 (65, 66, 67)31.5 ± 2.6Ti2Cu
Precipitate 4 (68, 79, 80)24.6 ± 0.5Ti3Cu

Share and Cite

MDPI and ACS Style

Fowler, L.; Masia, N.; Cornish, L.A.; Chown, L.H.; Engqvist, H.; Norgren, S.; Öhman-Mägi, C. Development of Antibacterial Ti-Cux Alloys for Dental Applications: Effects of Ageing for Alloys with Up to 10 wt% Cu. Materials 2019, 12, 4017. https://0-doi-org.brum.beds.ac.uk/10.3390/ma12234017

AMA Style

Fowler L, Masia N, Cornish LA, Chown LH, Engqvist H, Norgren S, Öhman-Mägi C. Development of Antibacterial Ti-Cux Alloys for Dental Applications: Effects of Ageing for Alloys with Up to 10 wt% Cu. Materials. 2019; 12(23):4017. https://0-doi-org.brum.beds.ac.uk/10.3390/ma12234017

Chicago/Turabian Style

Fowler, Lee, Nomsombuluko Masia, Lesley A. Cornish, Lesley H. Chown, Håkan Engqvist, Susanne Norgren, and Caroline Öhman-Mägi. 2019. "Development of Antibacterial Ti-Cux Alloys for Dental Applications: Effects of Ageing for Alloys with Up to 10 wt% Cu" Materials 12, no. 23: 4017. https://0-doi-org.brum.beds.ac.uk/10.3390/ma12234017

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop