Next Article in Journal
Influence of C and N on Strain-Induced Martensite Formation in Fe-15Cr-7Mn-4Ni-0.5Si Austenitic Steel
Next Article in Special Issue
Topology Optimisation for Compliant Hip Implant Design and Reduced Strain Shielding
Previous Article in Journal
External Corrosion Behavior of Steel/GFRP Composite Pipes in Harsh Conditions
Previous Article in Special Issue
Double-Level Energy Absorption of 3D Printed TPMS Cellular Structures via Wall Thickness Gradient Design
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Flexible Pressure Sensor with Micro-Structure Arrays Based on PDMS and PEDOT:PSS/PUD&CNTs Composite Film with 3D Printing

State Key Laboratory for Manufacturing Systems Engineering, School of Mechanical Engineering, Xi’an Jiaotong University, Xi’an 710049, China
*
Authors to whom correspondence should be addressed.
Submission received: 23 September 2021 / Revised: 27 October 2021 / Accepted: 28 October 2021 / Published: 29 October 2021
(This article belongs to the Special Issue Design and Application of Additive Manufacturing)

Abstract

:
Flexible pressure sensors are widely used in different fields, especially in human motion, robot monitoring and medical treatment. Herein, a flexible pressure sensor consists of the flat top plate, and the microstructured bottom plate is developed. Both plates are made of polydimethylsiloxane (PDMS) by molding from the 3D printed template. The contact surfaces of the top and bottom plates are coated with a mixture of poly (3,4-ethylenedioxythiophene) poly (styrene sulfonate) (PEDOT:PSS) and polyurethane dispersion (PUD) as stretchable film electrodes with carbon nanotubes on the electrode surface. By employing 3D printing technology, using digital light processing (DLP), the fabrication of the sensor is low-cost and fast. The sensor models with different microstructures are first analyzed by the Finite Element Method (FEM), and then the models are fabricated and tested. The sensor with 5 × 5 hemispheres has a sensitivity of 3.54 × 10−3 S/kPa in the range of 0–22.2 kPa. The zero-temperature coefficient is −0.0064%FS/°C. The durability test is carried out for 2000 cycles, and it remains stable during the whole test. This work represents progress in flexible pressure sensing and demonstrates the advantages of 3D printing technology in sensor processing.

1. Introduction

Due to the wide application of flexible pressure sensors in human motion [1,2,3], robot monitoring [4,5] and medical treatment [6,7,8,9], research on flexible pressure sensors has become popular in the past decade. Such sensors with high flexibility can convert pressure information input into an electrical signal output. Among them, capacitive and piezoresistive sensors are mostly reported. Capacitive sensors usually have two electrodes, sandwiching a dielectric layer. When pressure is applied, the distance between the electrodes changes, the dielectric constant of the dielectric layer changes or the electrode area changes [1,9,10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25]. By using different dielectric materials, changing the electrode size, etc., capacitive sensors meeting different requirements can be designed. However, due to the limitation of the size of electrodes, the capacitance is small, and the stray capacitance is relatively large, which is susceptible to external interference and affects the measurement accuracy.
The piezoresistive sensor has a simple structure, and the circuit design is easy [6]. This kind of sensor usually deforms under pressure and detects the pressure by the resistance change in three different ways: (1) The piezoresistive characteristics of the material itself [2,4,26]; (2) Doped carbon nanotubes, graphene, silver nanowires and other conductive fillers form more electrical contacts or a tunneling effect [3,5,27,28,29,30,31,32]; (3) The contact resistance of the contact area between the two electrodes changes [6,8,33,34,35,36,37]. For the third type of piezoresistive sensors, the common way to improve performance is to add fine microstructures onto the electrode contact surface. Compared with a device without microstructures [32], when an external pressure is applied within a certain range, the microstructure increases the change in the contact area between the two electrodes, improving the sensitivity of the sensor. By adjusting the shape and size of the microstructure, different performance sensors can be easily obtained. Micro pyramids are the most common microstructure in pressure sensors [6,33,34,36]. As reported by Choong’s work in 2014, a piezoresistive pressure sensor was achieved by coating a compressible substrate containing an array of micro pyramids, which was obtained by replication of silicon process templates, and had a sensitivity of 4.88 kPa−1 over a wide range of pressures from 0.37 to 5.9 kPa [6]. Moreover, microcylindrical and other structures were also reported and fabricated in a similar method [22,35,37].
Although the performance of these sensors is excellent and the silicon process is mature and precise, the fabrication process has its disadvantages. The silicon process is not only time-consuming and costly but can also generally only process planar structures. Complex surface structures, such as curved surfaces, are hard to process. It is necessary to study other fabrication processes, such as three-dimensional (3D) printing technologies [38]. Three-dimensional printing can directly generate parts of any shape from computer graphics data without machining, thereby greatly shortening the product development cycle and reducing costs. Moreover, 3D printing can also print some complicated appearances, such as curved surfaces and inclined surfaces, which are hard to fabricate by traditional silicon processes, expanding more ideas to design novel sensors.
Here, by 3D printing, the reasonable design and manufacturing method of a flexible pressure sensor is proposed. FEM is applied to simulate the stress distribution and resistance of sensors with different microstructures and density distributions. The results show that the sensor performance is dependent on the shape of microstructures, and the hemisphere is found to be a proper geometric structure that achieves the best sensor performance in terms of sensitivity and measurement range compared to pyramid and cone, while sensors with different hemisphere density distributions have similar responses but different measurement ranges. To simplify the manufacturing process, the templates with microstructures are fabricated by 3D printing. By molding the templates with microstructures, PDMS bottom plates with microstructures are created, and flat top plates without microstructures are obtained in the same way. Then, a thin layer of PEDOT:PSS and PUD mixture is evenly applied to the contact surface of the top and bottom plates and CNTs are distributed on the top of this layer of film electrode. Finally, the flat top plate and microstructured bottom plate are assembled to form the pressure before testing.

2. Materials and Methods

2.1. Sensor Design

The schematic diagram of the proposed flexible pressure sensors is shown in Figure 1a. The sensor was composed of upper and lower parts. The main body of the two parts was a flat square plate with a thickness of 1.3 mm and a side length of 15.0 mm. The surface of the lower part was evenly distributed with micro-structure protrusions, while the upper part was a completely flat plate.
Here we designed 6 different structures for the lower part: 2 × 2 hemispheres, 3 × 3 hemispheres, 4 × 4 hemispheres, 5 × 5 hemispheres with a diameter of 2.0 mm, 5 × 5 cones with a diameter of 2.0 mm on the bottom and 5 × 5 pyramids with a side length of 2.0 mm on the bottom, as shown in Figure 2.
To analyze the change trend of resistance under pressure, the sensor model was simplified [6], as shown in Figure 1b. The total resistance (R) consists of top plate resistance (Rt), contact resistance (Rc) and bottom plate resistance (Rb):
R = R t + R c + R b
When the pressure is applied, the change of resistance could be described:
Δ R = R R 0 = R t + R c + R b R t 0 + R c 0 + R b 0
Since the top plate resistance was almost invariable, Equation (2) could be simplified to Equation (3):
Δ R R c R c 0 + R b R b 0
According to Ohm’s law,
R = ρ L A
where L was the length of the resistor, A was the cross-sectional area and ρ was the resistivity.
Equation (3) was rewritten to Equation (5):
Δ R = ρ c L c A c L c0 A c0 + ρ b L b D b C b L b0 D b0 C b0
where Ac was the contact area, Lc was the film electrodes thickness at the contact area, Db was the film thickness at the side of micro-structure, Lb was the film length at the side of micro-structure and Cb was the perimeter of the contact area.
When the pressure was applied, Lc and Lb decreased, and Ac, Db and Cb increased, resulting in the resistance of the sensor decreasing.

2.2. Sensor Simulation

To analyze the influence of microstructure protrusions of different shapes and sizes on the performance of the sensor, the finite element method was introduced. The software used for simulation was COMSOL 5.6. Six sensor models with the different microstructures mentioned above were imported into the software, both top and bottom plates were modeled by hyperelasticity and the material model was the Mooney–Rivlin model, two parameters, with C10 2.4 × 105 Pa, C01 6.6 × 104 Pa and bulk modulus κ 1.25 × 107 Pa. Then external displacement was applied, pushing the top plate downward to make contacts with the microstructures on the bottom plate. The pressure distance increased from 0 to 0.6 mm, and the change curve between displacement and force and resistance was obtained. The specific results were as follows.
In the simulation results of the pressure change with the displacement of the depression, the protrusions of different structures were compared. As shown in Figure 3a, when the number of protrusions was 5 × 5, different structures had different pressure curves. In the same depression displacement of 0.6 mm, the sensor with hemispherical structures had the largest range of 44.09 kPa, while the sensor with pyramidal structures and the conical structures had a similar range, which is less than a quarter of that of the sensor with hemispherical structures.
Next, we studied the hemispheric protrusions with different distribution densities on the bottom plate surface of the same size. As shown in Figure 3d, it was obvious that as the number of hemispheres increases, the pressure also increases. Analysis of the data showed that the pressure was proportional to the number of hemispheres, and each hemisphere provided a pressure of approximately 1.76 kPa when the pressure displacement was 0.6 mm. This was also in line with common sense, and the sensor can be regarded as a parallel connection of different numbers of single hemispherical structure sensors. In this way, the higher the number of hemispheres, the larger the measurement range of the sensor.
Then the change of the sensor’s resistance with pressure was studied. As shown in Figure 3b,e, 6 types of sensors with different types and numbers of protrusions were compared. Although the structure and number of protrusions cause a huge difference in range, the resistance-pressure curves of all sensors in the same range were very similar. In the range of 0–5 kPa, the resistance rapidly decreased from the maximum value to 20 Ω. When the pressure was higher than 5 kPa, the resistance decreased very slowly. The inverse of the resistance was used to get the conductance. As shown in Figure 3c,f, the conductance changed almost linearly with pressure. The conductance-pressure curves of 5 × 5 hemispheres, pyramids and cones were relatively similar, while the conductance-pressure curves of sensors with different numbers of hemisphere protrusions almost overlap. No matter how the number of hemispheres changed, the output resistance of the sensor remained unchanged under pressure. Therefore, we could design sensors with different hemispherical density distributions according to the different ranges required by the measurement requirements, without the need for major modifications to the subsequent circuit.
Meanwhile, the stress of the sensors with pyramid and cone structures was concentrated on the top of the microstructure, where the top plate and the microstructures on the bottom plate were in contact. The stress of the sensor with a hemispherical structure was relatively dispersed, and the maximum stress was much smaller than that of the sensor with pyramid and cone structures. When the applied displacement was 0.6 mm, the maximum von Mises stress of pyramid, cone and hemisphere structures were 6.40 × 105, 7.24 × 105 and 2.15 × 105 Pa, respectively, as shown in Figure 4. Larger stress would cause the conductive film to be easily damaged.

2.3. Sensor Fabrication

The templates with micro-structure were designed, as shown in Figure 5 below.
The templates were divided into two parts, one part was the top plate, and the other was the bottom plate with different structure depressions. High-temperature-resistant resin (High Temp, Formlabs, Somerville, MA, USA) was used for processing the template with a 3D Digital Light Processing (DLP) printer (M-Jewelry U50, MAKEX, Ningbo, China). This printer is a desktop 3D printer with a lateral resolution of 50 µm and a thickness resolution of 5 µm. The high-temperature resin offers a heat deflection temperature (HDT) of 238 °C at 0.45 MPa. During printing, the template is printed from bottom to top in a vertical orientation.
After printing, we rinsed the template thoroughly with isopropanol and ethanol to remove resin residue. Then, the template was exposed to ultraviolet (UV) light in a UV curing machine (Cure3D, MAKEX, Ningbo, China) for 1 h to ensure complete curing. After that, the template was placed in an air convection oven (PG-2J, ESPEC, Osaka, Japan) and heated to 120 °C for 3 h and cooled with the oven to eliminate the internal stress of the template and prevent deformation in the pouring process, as shown in Figure 6a.
Next, the PDMS elastomer and curing agent (Sylgard 184, Dow Corning, Midland, MI, USA) were mixed evenly at a ratio of 10:1 and vacuumed to remove bubbles. The 3D printed template was heated to 100 °C in the oven for 4 h after the mixture was cast. After that, the top and bottom plates were obtained by peeling off the cured PDMS from the template, as shown in Figure 6b.
Then oxygen plasma was used to clean the top and bottom plates to enhance the hydrophilicity of the PDMS surface by the low-pressure plasma system (V6-G, Pink, Wertheim, Germany). Subsequently, a mixture of PEDOT:PSS (P Jet 700 N, Clevios, Hanau, Germany) and PUD (Tekspro 7360, WANHUA, Yantai, China), with a ratio of 9: 1, was spread evenly by drop-casting to the top and bottom plate surfaces and cured completely at 70 °C for 30 min, as shown in Figure 6c. Then the carbon nanotube’s water-based coating (XFEC01, XFnano, Nanjing, China) was diluted to 1%wt and applied on the PEDOT:PSS/PUD films in the same way to achieve a double-layer conductive film, as shown in Figure 6d.
Finally, the top and bottom plates were tied together by the Kapton tape, and the fabricated pressure sensor is shown in Figure 6e,f.
To measure the thickness of the film, the film step was prepared, and the film thickness was observed and measured with a 3D measuring laser microscope (LEXT OLS4100, OLYMPUS, Tokyo, Japan). Five cross-sections of the film step were measured, as shown in Figure 7a. Due to the unevenness of the film near the step (120–140 μm in the x-axis position), the average film thickness was calculated from the film thickness between 350 and 450 μm in the x-axis position, which was 4.99 ± 0.50 μm, as shown in Figure 7b.

3. Results

3.1. Experimental Setup

The test bench mainly consisted of two parts, a compression test machine (PT-1198G, POOTAB, Dongguan, China) and a high-precision multimeter (8846A, Fluke, Everett, WA, USA) [35], as shown in Figure 8. The sensor was placed on the test machine plate, and the force was applied to the sensor by adjusting the displacement of the squeeze head. The resistance change of the sensor was read through the high-precision multimeter. The experimental setup was put in a 25 °C clean room, where the environmental impact can be minimized.

3.2. Static Test

In order to evaluate the static performance of sensors with different microstructure arrays, we tested the six types of sensors processed above. The test range of the sensor with 2 × 2 hemisphere structure was 0–13.3 kPa, and the range of the rest of the five sensors was 0–22.2 kPa. The force load started from 0 kPa, and increased by 2.22 kPa each time, with each step holding for 20 s. After reaching the maximum range, it decreased by 2.22 kPa each time. The pressure was also held for 20 s, and the resistance change of the whole period was read through the high-precision multimeter. As shown in Figure 9a,b, at low pressure ranges (0–4 kPa), the sensor resistance decreased sharply, but at high pressure (>4 kPa), since the microstructure deformation of the sensor saturated with the increase in pressure, the resistance decrease speed is significantly reduced. This result was consistent with the conclusion of the previous FEM result.
By converting resistance to conductance, as shown in Figure 9c,d, it can be seen that the conductance-pressure curves of the six sensors are almost linear and almost overlap, which is similar to the simulation conclusion. Taking a 5 × 5 hemisphere structure sensor as an example, it can be obtained by the calculation that the sensitivity of the sensor is 3.54 × 10−3 S/kPa in the range of 0–22.2 kPa. The maximum conductance difference between loading and unloading was 0.0023 S at 8.89 kPa, and the hysteresis was 1.41%FS. This was due to the viscoelasticity of the flexible film and the substrate, which could only be minimized but not completely eliminated. The largest deviation of the resistance appeared at 0 kPa; it was considered that the contact between the top and bottom plates was not sufficient, so the deviation was relatively large.

3.3. Temperature Test

The temperature test of the pressure sensor with 5 × 5 hemispheres was conducted within a temperature range from 0 to 80 °C in the air convection oven. The output data is shown in Figure 10, and the maximum change of the output conductance was −0.302 mS at 80 °C. The zero-temperature coefficient was calculated, which was −0.0064%FS/°C. It might be caused by the thermal expansion of the PDMS substrate and the PEDOT:PSS/PUD film electrodes.

3.4. Durability Test

By controlling the movement of the compression test machine, the sensor with 5 × 5 hemispheres had undergone 2000 loading/unloading tests, and each loading/unloading process took 2 s. The data was read by the high-precision multimeter, and the results are shown in Figure 11.
Before 500 cycles, there was an obvious increase in conductance from 0.06 to 0.082 S during loading. The conductance of unloading remained stable at about 0.01 S during the whole test. Judging from the magnified images of 500–510 cycles and 1800–1810 cycles, the conductance change curve of each load/unload cycle was almost the same, which also reflected the good repeatability of the sensor. It can be seen from the rise and fall speed of the resistance that the response speed of the sensor was very fast.

3.5. Effect of Test on Electrode Films

The surfaces of the sensor before and after the test were observed using the scanning electron microscope (SEM) (Hitachi, SU8010, Japan), as shown in Figure 12. Figure 12a–c was the sensor image before the test. Under low magnification, stripes could be seen on the sensor surface, which was due to the 3D printing mold formed layer by layer, and the layer thickness was set to 50 μm during printing. Under high magnification, the distribution of carbon tubes on the surface of the sensor could be clearly seen. It can be seen in the electron microscope image of the sensor after the durability test that although the electrode film seemed intact at low magnification (Figure 12d), slight cracks on the electrode film can be found at high magnification (Figure 12e). At higher magnification, the loose CNTs have been compacted and embedded in the lower PEDOT:PSS/PUD hybrid film (Figure 12f).

4. Conclusions

In this work, we discussed the influence of protrusions with different morphologies and different density distributions on flexible pressure sensors performance and developed a new method of manufacturing sensors based on 3D printing technology. The elastic top and bottom plates of the sensor with micro-structure protrusions were made of PDMS, and the surfaces of the plates were coated with a conductive film, which was made from a mixture of PEDOT:PSS and PUD, and a layer of CNTs covered it. The top and bottom plates were obtained by replicating a 3D printed template. Compared with the previous templates obtained by the silicon process, 3D printing has the advantages of time-saving, low cost and being able to process unique shapes. By using FEM simulation, three sensors with different types of microstructures, including pyramid, cone and hemisphere, were analyzed, and the results show that the sensor with the hemispherical structure had the best performance. Furthermore, sensors with different hemisphere density distributions had similar responses. The difference was that the range of the sensor increased as the hemisphere density increased. All sensors were fabricated and tested. The sensor with 5 × 5 hemispheres had a sensitivity of 3.54 × 10−3 S/kPa and hysteresis of 1.41%FS in the range of 0–22.2 kPa. The zero-temperature coefficient was −0.0064%FS/°C. The durability test was carried out for 2000 cycles, and the sensor remained stable during the test. These results prove that 3D printing has great potential in the field of sensor manufacturing. In future research, higher precision 3D printers and suiTable 3D printing materials will optimize the processing and improve the performance of the sensor.

Author Contributions

Conceptualization, Y.Z.; methodology, Y.Z. and Y.S.; investigation, Y.S., X.P. and M.L.; writing—original draft preparation, Y.S.; writing—review and editing, Q.Z., D.Z. and X.L.; funding acquisition, Y.Z. and Q.Z. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the National Natural Science Foundation of China (Grant No. 51805425 and U20A20296) and the Ningbo major special project of the Plan “Science and Technology Innovation 2025” (Grant No. 2020Z023).

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Data sharing not applicable.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Laszczak, P.; Jiang, L.; Bader, D.L.; Moser, D.; Zahedi, S. Development and validation of a 3D-printed interfacial stress sensor for prosthetic applications. Med. Eng. Phys. 2015, 37, 132–137. [Google Scholar] [CrossRef]
  2. Lu, N.; Lu, C.; Yang, S.; Rogers, J. Highly Sensitive Skin-Mountable Strain Gauges Based Entirely on Elastomers. Adv. Funct. Mater. 2012, 22, 4044–4050. [Google Scholar] [CrossRef]
  3. Amjadi, M.; Pichitpajongkit, A.; Lee, S.; Ryu, S.; Park, I. Highly Stretchable and Sensitive Strain Sensor Based on Silver Nanowire–Elastomer Nanocomposite. ACS Nano 2014, 8, 5154–5163. [Google Scholar] [CrossRef]
  4. Park, Y.L.; Majidi, C.; Kramer, R.; Berard, P.; Wood, R.J. Hyperelastic pressure sensing with a liquid-embedded elastomer. J. Micromech. Microeng. 2010, 20, 6. [Google Scholar] [CrossRef] [Green Version]
  5. Xiao, X.; Yuan, L.; Zhong, J.; Ding, T.; Liu, Y.; Cai, Z.; Rong, Y.; Han, H.; Zhou, J.; Wang, Z.L. High-Strain Sensors Based on ZnO Nanowire/Polystyrene Hybridized Flexible Films. Adv. Mater. 2011, 23, 5440–5444. [Google Scholar] [CrossRef]
  6. Choong, C.L.; Shim, M.B.; Lee, B.S.; Jeon, S.; Ko, D.S.; Kang, T.H.; Bae, J.; Lee, S.H.; Byun, K.E.; Im, J.; et al. Highly Stretchable Resistive Pressure Sensors Using a Conductive Elastomeric Composite on a Micropyramid Array. Adv. Mater. 2014, 26, 3451–3458. [Google Scholar] [CrossRef] [PubMed]
  7. Liu, Z.; Ma, Y.; Ouyang, H.; Shi, B.; Li, N.; Jiang, D.; Xie, F.; Qu, D.; Zou, Y.; Huang, Y.; et al. Transcatheter Self-Powered Ultrasensitive Endocardial Pressure Sensor. Adv. Funct. Mater. 2019, 29, 1807560. [Google Scholar] [CrossRef]
  8. He, K.; Hou, Y.; Yi, C.; Li, N.; Sui, F.; Yang, B.; Gu, G.; Li, W.; Wang, Z.; Li, Y.; et al. High-performance zero-standby-power-consumption-under-bending pressure sensors for artificial reflex arc. Nano Energy 2020, 73, 104743. [Google Scholar] [CrossRef]
  9. Tee, B.C.K.; Chortos, A.; Dunn, R.R.; Schwartz, G.; Eason, E.; Bao, Z. Tunable Flexible Pressure Sensors using Microstructured Elastomer Geometries for Intuitive Electronics. Adv. Funct. Mater. 2014, 24, 5427–5434. [Google Scholar] [CrossRef]
  10. Mannsfeld, S.C.B.; Tee, B.C.K.; Stoltenberg, R.M.; Chen, C.; Barman, S.; Muir, B.V.O.; Sokolov, A.N.; Reese, C.; Bao, Z.N. Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers. Nat. Mater. 2010, 9, 859–864. [Google Scholar] [CrossRef]
  11. Fan, F.R.; Lin, L.; Zhu, G.; Wu, W.Z.; Zhang, R.; Wang, Z.L. Transparent Triboelectric Nanogenerators and Self-Powered Pressure Sensors Based on Micropatterned Plastic Films. Nano Lett. 2012, 12, 3109–3114. [Google Scholar] [CrossRef] [Green Version]
  12. Hu, W.; Niu, X.; Zhao, R.; Pei, Q. Elastomeric transparent capacitive sensors based on an interpenetrating composite of silver nanowires and polyurethane. Appl. Phys. Lett. 2013, 102, 083303. [Google Scholar] [CrossRef]
  13. Schwartz, G.; Tee, B.C.K.; Mei, J.; Appleton, A.L.; Kim, D.H.; Wang, H.; Bao, Z. Flexible polymer transistors with high pressure sensitivity for application in electronic skin and health monitoring. Nat. Commun. 2013, 4, 1859. [Google Scholar] [CrossRef] [PubMed]
  14. Boutry, C.M.; Nguyen, A.; Lawal, Q.O.; Chortos, A.; Rondeau-Gagné, S.; Bao, Z. A Sensitive and Biodegradable Pressure Sensor Array for Cardiovascular Monitoring. Adv. Mater. 2015, 27, 6954–6961. [Google Scholar] [CrossRef]
  15. Kwon, D.; Lee, T.-I.; Shim, J.; Ryu, S.; Kim, M.S.; Kim, S.; Kim, T.-S.; Park, I. Highly Sensitive, Flexible, and Wearable Pressure Sensor Based on a Giant Piezocapacitive Effect of Three-Dimensional Microporous Elastomeric Dielectric Layer. ACS Appl. Mater. Interfaces 2016, 8, 16922–16931. [Google Scholar] [CrossRef] [PubMed]
  16. Li, T.; Luo, H.; Qin, L.; Wang, X.W.; Xiong, Z.P.; Ding, H.Y.; Gu, Y.; Liu, Z.; Zhang, T. Flexible Capacitive Tactile Sensor Based on Micropatterned Dielectric Layer. Small 2016, 12, 5042–5048. [Google Scholar] [CrossRef] [PubMed]
  17. Cho, S.H.; Lee, S.W.; Yu, S.; Kim, H.; Chang, S.; Kang, D.; Hwang, I.; Kang, H.S.; Jeong, B.; Kim, E.H.; et al. Micropatterned Pyramidal Ionic Gels for Sensing Broad-Range Pressures with High Sensitivity. ACS Appl. Mater. Interfaces 2017, 9, 10128–10135. [Google Scholar] [CrossRef] [PubMed]
  18. Lee, K.; Lee, J.; Kim, G.; Kim, Y.; Kang, S.; Cho, S.; Kim, S.; Kim, J.-K.; Lee, W.; Kim, D.-E.; et al. Rough-Surface-Enabled Capacitive Pressure Sensors with 3D Touch Capability. Small 2017, 13, 1700368. [Google Scholar] [CrossRef]
  19. Bae, G.Y.; Han, J.T.; Lee, G.; Lee, S.; Kim, S.W.; Park, S.; Kwon, J.; Jung, S.; Cho, K. Pressure/Temperature Sensing Bimodal Electronic Skin with Stimulus Discriminability and Linear Sensitivity. Adv. Mater. 2018, 30, 1803388. [Google Scholar] [CrossRef]
  20. Boutry, C.M.; Kaizawa, Y.; Schroeder, B.C.; Chortos, A.; Legrand, A.; Wang, Z.; Chang, J.; Fox, P.; Bao, Z. A stretchable and biodegradable strain and pressure sensor for orthopaedic application. Nat. Electron. 2018, 1, 314–321. [Google Scholar] [CrossRef]
  21. Boutry, C.M.; Beker, L.; Kaizawa, Y.; Vassos, C.; Tran, H.; Hinckley, A.C.; Pfattner, R.; Niu, S.; Li, J.; Claverie, J.; et al. Biodegradable and flexible arterial-pulse sensor for the wireless monitoring of blood flow. Nat. Biomed. Eng. 2019, 3, 47–57. [Google Scholar] [CrossRef] [PubMed]
  22. Yang, J.; Luo, S.; Zhou, X.; Li, J.; Fu, J.; Yang, W.; Wei, D. Flexible, Tunable, and Ultrasensitive Capacitive Pressure Sensor with Microconformal Graphene Electrodes. ACS Appl. Mater. Interfaces 2019, 11, 14997–15006. [Google Scholar] [CrossRef]
  23. Yang, J.C.; Kim, J.-O.; Oh, J.; Kwon, S.Y.; Sim, J.Y.; Kim, D.W.; Choi, H.B.; Park, S. Microstructured Porous Pyramid-Based Ultrahigh Sensitive Pressure Sensor Insensitive to Strain and Temperature. ACS Appl. Mater. Interfaces 2019, 11, 19472–19480. [Google Scholar] [CrossRef]
  24. Asghar, W.; Li, F.; Zhou, Y.; Wu, Y.; Yu, Z.; Li, S.; Tang, D.; Han, X.; Shang, J.; Liu, Y.; et al. Piezocapacitive Flexible E--Skin Pressure Sensors Having Magnetically Grown Microstructures. Adv. Mater. Technol. 2020, 5, 1900934. [Google Scholar] [CrossRef]
  25. Ruth, S.R.A.; Beker, L.; Tran, H.; Feig, V.R.; Matsuhisa, N.; Bao, Z. Rational Design of Capacitive Pressure Sensors Based on Pyramidal Microstructures for Specialized Monitoring of Biosignals. Adv. Funct. Mater. 2020, 30, 1903100. [Google Scholar] [CrossRef]
  26. Ma, X.; Zhang, Q.; Guo, P.; Tong, X.; Zhao, Y.; Wang, A. Residual Compressive Stress Enabled 2D-to-3D Junction Transformation in Amorphous Carbon Films for Stretchable Strain Sensors. ACS Appl. Mater. Interfaces 2020, 12, 45549. [Google Scholar] [CrossRef] [PubMed]
  27. Cai, J.-H.; Li, J.; Chen, X.-D.; Wang, M. Multifunctional polydimethylsiloxane foam with multi-walled carbon nanotube and thermo-expandable microsphere for temperature sensing, microwave shielding and piezoresistive sensor. Chem. Eng. J. 2020, 393, 124805. [Google Scholar] [CrossRef]
  28. Gong, S.; Schwalb, W.; Wang, Y.; Chen, Y.; Tang, Y.; Si, J.; Shirinzadeh, B.; Cheng, W. A wearable and highly sensitive pressure sensor with ultrathin gold nanowires. Nat. Commun. 2014, 5, 3132. [Google Scholar] [CrossRef] [Green Version]
  29. Amjadi, M.; Yoon, Y.J.; Park, I. Ultra-stretchable and skin-mountable strain sensors using carbon nanotubes-Ecoflex nanocomposites. Nanotechnology 2015, 26, 11. [Google Scholar] [CrossRef] [PubMed]
  30. Zheng, Y.; Li, Y.; Dai, K.; Liu, M.; Zhou, K.; Zheng, G.; Liu, C.; Shen, C. Conductive thermoplastic polyurethane composites with tunable piezoresistivity by modulating the filler dimensionality for flexible strain sensors. Compos. Part A Appl. Sci. Manuf. 2017, 101, 41–49. [Google Scholar] [CrossRef]
  31. Tallman, T.N.; Gungor, S.; Wang, K.W.; Bakis, C.E. Tactile imaging and distributed strain sensing in highly flexible carbon nanofiber/polyurethane nanocomposites. Carbon 2015, 95, 485–493. [Google Scholar] [CrossRef] [Green Version]
  32. Wang, Y.; Wang, L.; Yang, T.T.; Li, X.; Zang, X.B.; Zhu, M.; Wang, K.L.; Wu, D.H.; Zhu, H.W. Wearable and Highly Sensitive Graphene Strain Sensors for Human Motion Monitoring. Adv. Funct. Mater. 2014, 24, 4666–4670. [Google Scholar] [CrossRef]
  33. Li, H.; Wu, K.; Xu, Z.; Wang, Z.; Meng, Y.; Li, L. Ultrahigh-Sensitivity Piezoresistive Pressure Sensors for Detection of Tiny Pressure. ACS Appl. Mater. Interfaces 2018, 10, 20826–20834. [Google Scholar] [CrossRef]
  34. Chou, H.-H.; Nguyen, A.; Chortos, A.; To, J.W.F.; Lu, C.; Mei, J.; Kurosawa, T.; Bae, W.-G.; Tok, J.B.H.; Bao, Z. A chameleon-inspired stretchable electronic skin with interactive colour changing controlled by tactile sensing. Nat. Commun. 2015, 6, 8011. [Google Scholar] [CrossRef]
  35. Park, H.; Jeong, Y.R.; Yun, J.; Hong, S.Y.; Jin, S.; Lee, S.J.; Zi, G.; Ha, J.S. Stretchable Array of Highly Sensitive Pressure Sensors Consisting of Polyaniline Nanofibers and Au-Coated Polydimethylsiloxane Micropillars. ACS Nano 2015, 9, 9974–9985. [Google Scholar] [CrossRef] [PubMed]
  36. Kim, K.; Jung, M.; Kim, B.; Kim, J.; Shin, K.; Kwon, O.S.; Jeon, S. Low-voltage, high-sensitivity and high-reliability bimodal sensor array with fully inkjet-printed flexible conducting electrode for low power consumption electronic skin. Nano Energy 2017, 41, 301–307. [Google Scholar] [CrossRef]
  37. Jeong, C.; Ko, H.; Kim, H.-T.; Sun, K.; Kwon, T.-H.; Jeong, H.E.; Park, Y.-B. Bioinspired, High-Sensitivity Mechanical Sensors Realized with Hexagonal Microcolumnar Arrays Coated with Ultrasonic-Sprayed Single-Walled Carbon Nanotubes. ACS Appl. Mater. Interfaces 2020, 12, 18813–18822. [Google Scholar] [CrossRef] [PubMed]
  38. Liu, M.; Zhang, Q.; Zhao, Y.; Liu, C.; Shao, Y.; Tong, X. A high sensitivity micro-pressure sensor based on 3D printing and screen-printing technologies. Meas. Sci. Technol. 2020, 31, 035106. [Google Scholar] [CrossRef]
Figure 1. The proposed pressure sensor: (a) basic structure; (b) simplified sensor model.
Figure 1. The proposed pressure sensor: (a) basic structure; (b) simplified sensor model.
Materials 14 06499 g001
Figure 2. Schematic diagram of the designed sensors with 6 different structures: (a) 2 × 2 hemispheres; (b) 3 × 3 hemispheres; (c) 4 × 4 hemispheres; (d) 5 × 5 hemispheres; (e) 5 × 5 cones; (f) 5 × 5 pyramids.
Figure 2. Schematic diagram of the designed sensors with 6 different structures: (a) 2 × 2 hemispheres; (b) 3 × 3 hemispheres; (c) 4 × 4 hemispheres; (d) 5 × 5 hemispheres; (e) 5 × 5 cones; (f) 5 × 5 pyramids.
Materials 14 06499 g002
Figure 3. FEM results of the sensors with different microstructures: (ac) Sensors with 5 × 5 hemispheres, pyramids and cones; (df) Sensors with different density distribution of hemispheres.
Figure 3. FEM results of the sensors with different microstructures: (ac) Sensors with 5 × 5 hemispheres, pyramids and cones; (df) Sensors with different density distribution of hemispheres.
Materials 14 06499 g003
Figure 4. Von Mises stress of (a) pyramid, (b) cone and (c) hemisphere structures under 0.6 mm of displacement.
Figure 4. Von Mises stress of (a) pyramid, (b) cone and (c) hemisphere structures under 0.6 mm of displacement.
Materials 14 06499 g004
Figure 5. Designed templates.
Figure 5. Designed templates.
Materials 14 06499 g005
Figure 6. The fabrication process of sensors: (a) Template printing; (b) Template after cleaning and curing; (c) Top and bottom plates; (d) Plates with film electrodes; (e,f) Assembled sensor.
Figure 6. The fabrication process of sensors: (a) Template printing; (b) Template after cleaning and curing; (c) Top and bottom plates; (d) Plates with film electrodes; (e,f) Assembled sensor.
Materials 14 06499 g006
Figure 7. (a) The thickness of five cross-sections of the film; (b) Average thickness of the film between 350–450 μm in the x-axis position.
Figure 7. (a) The thickness of five cross-sections of the film; (b) Average thickness of the film between 350–450 μm in the x-axis position.
Materials 14 06499 g007
Figure 8. Experimental Setup.
Figure 8. Experimental Setup.
Materials 14 06499 g008
Figure 9. Sensors static test results: (a,c) Sensors with different hemispheres distribution densities; (b,d) Sensors with different structures.
Figure 9. Sensors static test results: (a,c) Sensors with different hemispheres distribution densities; (b,d) Sensors with different structures.
Materials 14 06499 g009
Figure 10. Thermal zero drift of the sensor.
Figure 10. Thermal zero drift of the sensor.
Materials 14 06499 g010
Figure 11. Durability test results.
Figure 11. Durability test results.
Materials 14 06499 g011
Figure 12. SEM images of sensors before (ac) and after (df) the test: (a,d) Surface of the structure; (b,c,e,f) Top of the hemisphere under higher magnification.
Figure 12. SEM images of sensors before (ac) and after (df) the test: (a,d) Surface of the structure; (b,c,e,f) Top of the hemisphere under higher magnification.
Materials 14 06499 g012
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Shao, Y.; Zhang, Q.; Zhao, Y.; Pang, X.; Liu, M.; Zhang, D.; Liang, X. Flexible Pressure Sensor with Micro-Structure Arrays Based on PDMS and PEDOT:PSS/PUD&CNTs Composite Film with 3D Printing. Materials 2021, 14, 6499. https://0-doi-org.brum.beds.ac.uk/10.3390/ma14216499

AMA Style

Shao Y, Zhang Q, Zhao Y, Pang X, Liu M, Zhang D, Liang X. Flexible Pressure Sensor with Micro-Structure Arrays Based on PDMS and PEDOT:PSS/PUD&CNTs Composite Film with 3D Printing. Materials. 2021; 14(21):6499. https://0-doi-org.brum.beds.ac.uk/10.3390/ma14216499

Chicago/Turabian Style

Shao, Yiwei, Qi Zhang, Yulong Zhao, Xing Pang, Mingjie Liu, Dongliang Zhang, and Xiaoya Liang. 2021. "Flexible Pressure Sensor with Micro-Structure Arrays Based on PDMS and PEDOT:PSS/PUD&CNTs Composite Film with 3D Printing" Materials 14, no. 21: 6499. https://0-doi-org.brum.beds.ac.uk/10.3390/ma14216499

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop