Article

Durability Enhancement Effect of Silica Fume on the Bond Behavior of Concrete–PCM Composites under Environmental Conditions

by
Mahmudul Hasan Mizan
1,2,* and
Koji Matsumoto
1
1
Graduate School of Engineering, Hokkaido University, Hokkaido 060-0808, Japan
2
Department of Civil Engineering, Khulna University of Engineering & Technology, Khulna 9203, Bangladesh
*
Author to whom correspondence should be addressed.
Submission received: 23 February 2023 / Revised: 19 April 2023 / Accepted: 25 April 2023 / Published: 26 April 2023
(This article belongs to the Special Issue Sustainable Fiber Reinforced Cementitious Materials)

Abstract

:
The long-term performance of the concrete–polymer cement mortar (PCM) interface under environmental exposure is crucial to the safety of the PCM overlaying method as the environmental exposure of the repaired structures caused further degradation of the interface, leading to a significant reduction in intended service life. This study investigates the durability enhancement effect of silica fume of the concrete–PCM interface, considering an individual action of elevated temperature (e.g., 60 °C) [constant (short and moderate duration) and cyclic conditions] and moisture content [continuous immersion and wetting/drying (W/D) cycle]. Our previous research confirmed that the use of silica fume forms more C-S-H with strong binding force and enhances the interfacial bonding strength due to the denser microstructure at the interface, and it is expected to be utilized for durability purposes under the aforementioned exposure conditions. Under all elevated temperature exposure conditions, the reduction percentage of the interfacial performance corresponding to the respective reference specimens reduced significantly with the inclusion of silica fume with overlay material. The occurrence of interface fracture at lower load and a greater number of pure interface fracture modes observed in normal PCM specimens compared to modified PCM specimens indicates a positive influence of higher adhesion with better durability of modified PCM overlay with substrate concrete. Under both conditions of moisture content, significant reduction in interfacial strength was observed in normal PCM specimens. In all cases, the reducing ratio of interfacial strength was higher in normal PCM compared to modified PCM, indicating a positive influence of silica fume under moisture content. Furthermore, silica fume inclusion shifts the fracture mode from pure interfacial fracture to composite fracture mode, indicating a positive response of silica fume to improve the resistance of interface fracture under moisture content. Conclusively, the use of silica fume improves concrete–overlay layer adhesion and enhances the bonding durability under environmental exposure.

1. Introduction

The performance of mortar or concrete significantly improves with the use of functional polymer materials or admixtures, as observed in several past experimental studies [1,2,3,4,5,6]. Different nanomaterials such as zinc oxide, titanium dioxide, or industrial waste with fibers were also used as a partial replacement of cement to prepare concrete or mortar with long-term strength and durability [7,8]. Recently, PCM (polymer cement mortar) has become the dominant material in the construction industry and is used as a popular repairing material as it possesses very compatible properties with respect to workability, adhesion, frost resistance, durability, permeability, and rate of shrinkage with concrete [9,10,11,12,13,14,15]. The PCM overlaying method has broad application prospects to improve load resistance, reduce deformation, and alleviate stress in existing structures, such as dams, bridge decks, and highway pavement slabs [16,17,18]. The concrete–PCM interfacial bonding properties are considered a very important factor. Many experimental studies in the past [19,20,21] observed a weakest link at the concrete–PCM interface of the PCM overlaying method. In technical literature, many studies revealed that a supplementary cementitious material such as silica fume can be used as a filler, pozzolan, or admixture to improve the performance of mortar and concrete [22,23,24,25]. In the previous study [26,27,28,29,30], it has also been shown that silica fume modified PCM as a repair material significantly improves the concrete–PCM interfacial bond, thus offering a broad prospect for the application of the PCM overlaying method for the strengthening of deteriorated reinforced concrete (RC) structures.
In practice, the strengthened structures are put into immediate service based on achieving adequate substrate concrete–repair materials bond strength in a short duration. In many cases, the short-term strength gain of the strengthened members does not ensure long-lasting and durable repairs because the long-term properties of the substrate concrete and repair material can be significantly different from the properties measured at early ages. The strengthened members are frequently located in harmful media and severe environments in the service life stage, causing early degradation and performance deterioration [31]. The durability issue under environmental conditions considering monolithic samples has been observed via experimental investigation in many previous studies [32,33,34,35,36,37]. In the technical literature, few studies have also been found that observed the durability issue on composite (repaired) samples under a freeze–thaw cycle [38,39,40], elevated temperature [41,42,43,44,45], etc. Severe degradation of the interfacial properties of the composite samples was found during long-term exposure. Therefore, the long-term performance of strengthened members under severe environmental exposure should be achieved along with the short-term bonding strength of the newly overlaid PCM layer with substrate concrete from the viewpoint of practical application of this method.
Temperature and moisture are considered to be one of the major factors affecting the durability of concrete structures. Temperature in some regions of the world, especially in the tropical zone or some parts of North America, rises up to 60 °C in summer. This temperature rise due to global warming or non-sustainable development also accelerates the further deterioration of the concrete structures [46,47]. Concrete structures are also exposed to cyclic temperature instead of constant temperature. In such environmental conditions, mismatched properties between concrete and repair material may occur, and repaired deteriorated RC structures, especially the adhesive interface, become more vulnerable. Both concrete and repair materials must be durable in severe environmental exposure. Many researchers have investigated the change in the microstructure of the concrete [48,49,50] and the mechanical performance degradation of the concrete [51,52,53] after exposure to high temperature. The mechanical behavior of concrete was degraded to different degrees after high-temperature exposure. Repair materials such as PCM are also sensitive to high temperatures. In the previous experimental study [54], a flexural strength reduction of about 91.6% was reported at 90 °C. The bond strength and the constituent properties of the materials are strongly connected [55]. Therefore, the degradation of the properties of concrete and repair materials directly influenced the bonding strength under severe environmental conditions. In the past experimental study [41,42,43], the performance of the concrete–PCM interface at a different temperature levels up to 60 °C was explored experimentally for a short-duration temperature exposure. At a temperature exposure of 60 °C and 40 °C, a significant reduction in interfacial shear strength was reported compared to 20 °C. Reduction in interfacial strength was also observed under different moisture content conditions (continuous immersion in water and wetting/drying cycles) [44,45]. A detrimental influence of elevated-temperature exposure for a short duration on flexural behavior of the PCM-strengthened RC beams, such as a reduction in flexural strength, the occurrence of debonding failure, and an increase in crack width and crack spacing, was also observed experimentally [56,57,58,59]. Additional stress is generated at the bond surface when exposed to a hot and dry environment, leading to failure of the interface at a lower load [9]. Volumetric change in the two constituents’ materials (concrete and overlay materials) with higher moisture absorption also generates additional stress at the interface and creates a condition of generating cracks [13].
Our previous research [28,29,30] confirmed that the modified PCM with silica fume forms more C-S-H with strong binding force and enhances the bonding properties of substrate concrete and the repair material due to the denser microstructure at the interface. It is expected to be utilized to enhance the durability of the interface under harsh environmental conditions that should be taken into consideration for the worldwide application of this overlaying method. Examples of harsh environmental conditions include continuous and cyclic immersion in water, exposure on the hottest day, peak summer season, seasonal temperature variation, and day–night temperature variation. The aforementioned issues should be investigated for long-term design durability. As a repair material, the modified PCM with silica fume is expected to perform better in the long run under harsh environments as silica fume can cause a chemical reaction and form more C-S-H with strong binding force [30]. Due to the extreme fineness of silica fume, it fills the void, resulting in lower porosity at the interface that can hold less moisture at the beginning. Thus, it may reduce the effect of volumetric change under severe environmental conditions.
Although different individual and coupling environmental conditions have an impact on the concrete–PCM interfacial bond, the influence of some of the individual environmental conditions on the concrete–PCM interface was considered as an experimental parameter on a priority basis. Considering the aforementioned issue, Series-I of this study investigates the durability enhancement effect of silica fume of the concrete–PCM interface, considering an individual action of elevated temperature (e.g., 60 °C) for constant [short (at 60 °C for 3 days) and moderate duration (at 60 °C for 36 days)] and cyclic conditions [day–night and seasonal variation] in the laboratory. In Series-II, the performance evaluation of the bond strength considering durability enhancement was explored under different moisture content conditions [continuous immersion in water up to 96 days and up to 24 W/D cycles]. Current experimental data can provide some theoretical foundation to researchers and structural engineers on the PCM overlaying method of deteriorated concrete structure strengthening under harsh environmental conditions. The findings of this research can help the practitioner in selecting a suitable repair overlay material and the manufacturer of PCM to produce new PCM with improved functionality to use under severe environmental conditions.

2. Experimental Outline

2.1. Materials

Substrate concrete with a target compressive strength of 40 MPa was used in this experimental work. It was fabricated by mixing commercially available normal Portland cement, coarse aggregate, fine aggregate, tap water, water reducer, and air-entraining agent. The specific properties of the different constituents of substrate concrete are mentioned in our previous study [30]. The substrate concrete was chosen with relatively higher compressive strength to achieve brittle/sudden failure mode along the concrete–PCM interface. The interfacial bond strength highly depends on the mechanical properties of the constitutive materials. The reduction in the bond behavior could be more obvious with the higher compressive strength of the substrate concrete. The mix proportion used in this study to prepare one cubic meter of substrate concrete is shown in Table 1.
The second type of material was the pre-mixed PCM containing poly acrylic ester (PAE) provided by the company. All the ingredients were mixed by the manufacturer in a specific ratio to fabricate gray-color PCM powder. At the time of the application, a water–binder ratio of 15% was used in this study as per the company’s recommendation to prepare the PCM mix. X-ray fluorescence (XRF) analysis was performed to evaluate the elemental oxides of the PCM used in this study. The major constituents observed using XRF analysis were Al2O3 (4.07%), SiO2 (16.39%), SO3 (2.57%), CaO (74.07%), and Fe2O3 (2.90%).
The third material was silica fume, which was used to prepare modified PCM for proper adhesion between concrete and PCM. Gray ultrafine silica fume with a specific surface area of 15–20 m2/g, a relative density of 150–700 kg/m3, a specific gravity of 2.2–2.3 and an average particle size of 0.15 µm is used in this study. The use of silica fume causes a need for more water, as the high surface area and small particle size of silica fume demand more water. A small amount of silica fume results in less C-S-H at the interface, whereas material stagnation is caused by using a large amount of silica fume [60]. Based on the findings of previous studies [28], a 5% silica fume of PCM mass was used in this study. Since silica fume powder is not liquid and is difficult to spread in the interface, it was used by mixing into PCM powder right before overlaying and hydrating together. Superplasticizer of 1.0% of the PCM mass was mixed in preparing modified PCM repair material to prevent the formation of silica fume lumps, whereas it was not used to prepare normal PCM repair material (without silica fume) following the outcome of trial flow test by the author and previous group research in our team [28,29,30]. The use of superplasticizer has no impact on the mechanical performance of the composites as observed in the trial test by the author. The mix proportion of repair material is shown in Table 2.

2.2. Specimen Preparation

Cylindrical specimens of size 100 mm × 200 mm and 50 mm × 100 mm were cast and used to measure the compressive strength of concrete and PCM, respectively. A polythene sheet was used to wrap the molds to avoid the moisture evaporation. Twenty-four hours after casting, all the formworks were demolded, and the concrete specimens were submerged in a tub of water for 28 days for proper curing. The PCM specimens were cured in water for 7 days followed by dry curing for 21 days to achieve better strength of the PCM specimens. Wet curing helps the hydration process, whereas dry conditions curing benefits the formation of polymer films [61].
The composite specimens were prepared by casting concrete and PCM on different dates. A portion of the concrete specimens (100 mm × 100 mm × 50 mm) was cast first, followed by pouring PCM (100 mm × 100 mm × 25 mm) to prepare the specimens of size 100 mm × 100 mm × 75 mm. Taking a large number of composite specimens into account, wooden molds were prepared for the casting of concrete of sizes 100 mm × 100 mm × 50 mm. In past research [62,63,64], the surface roughness of the concrete substrate has been extensively studied for improving the interlocking of the overlay, and a positive influence has been observed. One surface of the concrete specimens with dimensions 100 mm × 100 mm was treated to prepare a rough surface for better bonding. Following the previous studies [30,56], some amount of retarder was spread at the bottom of the molds before pouring concrete to prepare the surface roughness. It is possible to obtain a uniform rough surface with less/no damage of the substrate concrete using this method of surface roughness preparation. Before demolding, the bottom layer of the mold was removed first, and the concrete surface was exposed to the environment after 24 of casting. Due to the use of a retarder, the exposed concrete surface was not fully hard. The soft concrete surface was then sprayed with a strong jet of water until coarse aggregates were exposed to resemble a rough substrate concrete surface as shown in Figure 1a.
After demolding, the concrete was cured in wet condition for two weeks followed by dry curing for three months to resemble the existing concrete of the real infrastructure. To prepare composite specimens, cured concrete specimens of size 100 mm × 100 mm × 50 mm were put into the mold of 100 mm × 100 mm × 75 mm. The treated rough substrate concrete surface was kept upright in the mold. Good attention was paid in the following conditions before casting PCM: (i) removing of any dust with high air pressure on the treated surface and (ii) saturated concrete substrate with a dry surface for adequate bonding. Details of the procedure of the cleaning of the dust and achieving saturated surface dry condition is explained in our previous study [30]. The overlay material was mixed using a hand mixer for 1.5 min as shown in Figure 1b and troweled in two layers as shown in Figure 1c, with a time interval of 180 min to prepare composite specimens of size 100 mm × 100 mm × 75 mm. The curing methodology of the composite specimen was similar to the curing of PCM bulk cylindrical specimens previously mentioned.

2.3. Exposure Condition

Composite specimens were exposed in two series to study the influence of elevated temperature and moisture content in the laboratory, which resemble real environmental conditions. The specific duration of exposure under different conditions was chosen following the previous study [41,42,43,44,45] to keep the exposure duration as long as possible considering the time restraint in the laboratory and to infer longer-term applicability of the mentioned factors.

2.3.1. Elevated Temperature

In some regions of the world, the temperature fluctuates and may reach up to extreme temperature of about 60 °C from an ambient condition of 20 °C. The durability of the bonding of repair material to substrate concrete may be affected by this elevated temperature. In some regions, concrete structures are also exposed to cyclic temperature instead of constant temperature. To investigate this effect in detail, composite specimens were exposed to four different temperature variations in the laboratory as presented in Figure 2a–d.
The first condition was the exposure of composite specimens at a constant temperature of 60 °C for 3 days (Figure 2a), abbreviated as “TSD” (short-duration exposure). In the second condition, the composite specimen was put in an oven at a constant temperature of 60 °C for 36 days to resemble long-term exposure, abbreviated as “TMD” (moderate-duration exposure) (Figure 2b). These conditions were considered to simulate a specific time period in a tropical region such as summer season where temperature may rise up to 60 °C. Concrete structures were also exposed to cyclic temperature conditions instead of constant temperature conditions, which were also adopted in this study to represent real environmental conditions. Temperature change during day and night was considered by putting the composite specimen in a programmed oven at 60 °C for 12 h and at 30 °C for another 12 h, abbreviated as “TDN” (day and night variation) (Figure 2c). Seasonal variation of the temperature was also considered by replacing four seasons of a year with one day in the laboratory. The repaired specimens were exposed for 24 h in each condition of 60 °C in the oven, 20 °C in the water, 5 °C in the oven, and 25 °C in the oven to represent the summer season, rainy season, winter season, and at the ambient condition at 25 °C in the spring season, respectively (Figure 2d). One cycle in seasonal variation exposure was completed in 4 days. In all cases, the testing conditions were kept similar. After every exposure condition, the specimens were cooled down and tested at room temperature after cooling down. The summary of exposure conditions to study the influence of elevated-temperature exposure is shown in Table 3.

2.3.2. Moisture Content

To investigate the influence of moisture on the concrete–PCM interfacial bonding strength, composite specimens repaired with normal and modified PCM were exposed to wetting and drying cycles (W/D cycles). This condition was considered to simulate the simultaneous wet and dry exposure conditions of the RC structures in rain (wet) and summer (dry), respectively. For one W/D cycle, the specimens were submerged in water for 2 days to obtain wetting conditions followed by air exposure in the laboratory for 2 days to obtain the dry condition. Different researchers used different test methods during the wetting and drying cycles [61]. In this research work, the test was performed in a wet state after exposure to 0, 12, and 24 W/D cycles. Some RC structures experienced continuous immersion in water such as dams. Therefore, this exposure condition of continuous immersion in water at room temperature was also adopted in this study. For continuous wet conditions, the specimens were submerged in water continuously. The specimens were taken out from the water after 48 and 96 days of continuous immersion in water just before the testing, and the test was conducted in wet conditions. The process of W/D cycles and continuous immersion in water and the summary of exposure conditions and the number of specimens considered to study the influence of moisture are described in Figure 3 and Table 3, respectively.

2.4. Testing Procedure

The compressive strength of substrate concrete, normal PCM, and modified PCM was evaluated by conducting a compressive strength test after 28 days of curing according to the standard test method ASTM C39 [65]. The compressive strength of 41.6, 42.2, and 54.8 MPa (average of three specimens) was recorded for substrate concrete, normal PCM, and modified PCM, respectively. The modified PCM with silica fume improves compressive strength by about 30%. The compressive strength of the constituent overlay materials was also measured after 90 days of casting. An increase of 17% in strength was observed for modified silica PCM specimens due to the pozzolanic reaction of silica fume, but almost similar strength was obtained for the case of normal PCM specimens.
Different bond strength tests can be found in the technical literature to access the interfacial bond, such as splitting tensile, bi-surface shear, direct single-surface shear, and slant shear [66,67,68]. Among the test methods, single or double shear and slant shear tests have been widely used to evaluate the interface shear strength. Single or double shear have the disadvantages of local compressive failure or bending crack instead of adhesive failure [69]. The slant shear test leads to higher bonding strength due to increase in friction and is greatly influenced by the size and axis at the shear plane [67]. The use of the in-house testing method of interfacial strength was not widely accepted due to the complex test setups. Momayez et al. [68] proposed a bi-surface shear strength test to evaluate interfacial shear strength that does not require any special form, can be fabricated easily, and gives less variation in results. Considering the ease of specimen preparation, simple loading method, and many specimens, the bi-surface shear test (scheme shown in Figure 4) was adopted in this research work. The interfacial shear strength of the composite specimens was evaluated by using Equation (1).
τ m a x = P u 2 A
where τ m a x is the interfacial shear strength, P u is the ultimate load, and A is area of the connected interface.

3. Test Results and Discussion

3.1. Influence of Elevated Temperature

3.1.1. Short- and Medium-Duration Exposure

The composite specimens were exposed to a constant 60 °C temperature for 3 days to study the influence of short-duration exposure (TSD) and for 30 days to study the influence of long time exposure (TMD). After the exposure, the specimens were kept in the laboratory at room temperature for 24 h to cool them down and tested at room temperature. Following the previous study [70], the specimens were cooled down before testing, in which higher bond strength reduction was observed after cooling than at elevated temperature. The maximum stress capacity of the composite specimens under TSD and TMD is shown in Figure 5. The reduction in interfacial shear strength with exposure to TSD conditions compared to without exposure cases (TCON) was observed by approximately 19% and 8% for normal and modified PCM specimens, respectively. The degradation of interfacial strength further increased with the increase of exposure time (TMD condition), approximately 22% and 16% for normal and modified PCM specimens, respectively. The reduction in the bond strength at elevated temperature is consistent with the results of previous studies [41,42,43,70] considering normal PCM overlay material under short- (1 day) and moderate-duration (30 days) exposures. The interface condition is one of the governing factors for the mechanical performance of the composite specimens. In a study by Xie et al. [71], the interface was stated as the most porous layer compared to the rest of the specimens. The porosity further increases and leads to a further reduction in bond strength at an elevated temperature [72]. Different thermal expansion coefficients between concrete and PCM generate high internal thermal stresses and micro-cracks, subsequently causing weak bond strength with a change in temperature [56].
The higher percentage of bond strength reduction in normal PCM specimens might be due to the presence of higher porosity at the normal PCM–concrete interface. During drying at high temperature, some of the fine pores collapsed, resulting in larger pores and reduced strength with an increase in porosity [72,73]. In all exposure conditions, higher bong strength was observed in modified PCM specimens compared to normal PCM specimens (35.3% after TSD exposure and 27.3% after TMD exposure), as presented in Figure 5. The formation of more hydrogen bonds with strong binding force at the interface with silica fume inclusion [30] leads to acquiring a good concrete–PCM bond, thus reducing the damage initiation under elevated temperature. In addition, a denser microstructure with silica fume incorporation improves the structure of the interface with less porosity, thus reducing the influence of elevated temperature and resulting in higher interfacial strength.
The behavior of the composite specimens with silica fume inclusion under exposure to constant elevated temperature was also discussed in light of the fracture mode. The fracture modes are named by identifying the fracture location of the composite specimens during or after the loading test. The possible fracture modes of the composite specimens are shown in Figure 6. The fracture mode of all the composite specimens evaluated after the loading test under TSD and TMD along with TCON is presented in Figure 7a. The specimens were designated as follows: “N” as normal PCM and “M” as PCM modified with 5% silica fume followed by the specific exposure conditions.
Adhesive pure interface (I) fracture mode was observed as a major failure type in composite specimens repaired with normal PCM, both in control (TCON) and exposure conditions (TSD and TMD). Examples of adhesive pure interface (I) fracture mode are shown in Figure 7b. The composite specimens repaired with modified PCM exhibited one “(I)” fracture mode under TSD and TMD, whereas the TCON specimen do not include any “(I)” fracture mode. An example of composite fracture mode (C-P) of the composite specimens repaired with modified PCM is shown in Figure 7c. PCM attachments were found in almost the whole substrate concrete surface, which indicates the degradation of PCM more than the degradation of the adhesive interface as PCM is sensitive to high temperatures [61,74]. The higher number of specimen failures in composite fracture mode in modified PCM cases indicates higher concrete–overlay material adhesion with better durability under short- and long-duration exposure at elevated temperature.

3.1.2. Day–Night and Seasonal Variation Temperature Cycle

The real environmental condition was assumed considering cyclic temperature exposure by simulating the day–night cycle and seasonal variation for the durability of the repaired system and was provided in the laboratory in a programmed oven. The temperature was set at 60 °C for 12 h and 30 °C for another 12 h for the day–night variation case (TDN) and tested after 30 days of exposure. Interfacial strength reduction was observed under TDN in both normal (29%) and modified PCM (15%) specimens compared to its corresponding control specimens (TCON), as presented in Figure 8. Similar trends of bond strength reduction of about 27% from the control specimens were also observed in the previous study [75], considering normal PCM overlay material under TDN exposure for 30 days. A more detrimental influence of elevated temperature under TDN (cyclic temperature cycle) were observed on bond strength than under TSD or TMD (constant temperature exposure) in this study and in the previous study [70,75]. Due to cyclic temperature exposure, it will cause either a contraction or residual expansion at the interface, increase strain, and subsequently reduce bond strength [73].
The percentage reduction in the interfacial strength under TDN compared to TCON was almost half for modified PCM than that of normal PCM specimens. Strength increases of about 42% were observed with silica fume inclusion with PCM under TDN. This indicates durability enhancement of silica fume as a repaired mortar under elevated temperature. The fracture mode was observed as “(I)” for all normal PCM specimens under TDN, whereas two out of three specimens with modified PCM exhibited composite (I-P) fracture mode, as presented in Figure 9a. Even though the PCM is very sensitive to high temperatures [54,74], the occurrence of “(I)” fracture in normal PCM specimens (Figure 9b) indicates that the normal PCM–concrete interface is more vulnerable under cyclic temperature condition exposure. In contrast, in the pictural view of the fracture surface of the modified PCM specimen, the PCM attachment on the concrete side was observed as shown in Figure 9c, which verifies the degradation of PCM more than the adhesive interface at elevated temperature.
The temperature variation of four seasons in a year (summer, rainy, winter, and spring) was simulated by exposing the specimen to each environment for 24 h in the laboratory. The mechanical loading test was performed to evaluate the bonding strength after 12 cycles of exposure (48 days, 4 days to complete one cycle). The strength reductions of 24.7% and 13.5% were observed under TSV for normal and modified PCM, respectively, compared to TCON specimens, as presented in Figure 8. Strength reduction of about 24% was observed in the previous study [75] after the 10th cycle of seasonal variation exposure considering normal PCM overlay material. Higher bond strength reduction was observed in the TSV condition than in TSD or TMD. Similar trends of strength reduction under cyclic and constant temperature exposure were also observed in the previous study [70,75]. This might be due to the fact that the degraded polymers in the PCM cannot recover fully due to the cyclic temperature variation [74]. Owing to cyclic conditions, additional stress may generate at the interface and create a condition of generating micro-cracks, resulting in a reduction in the bond strength. Though the exposure duration under TSV is higher than TDN, the later exposure condition resulted in more degradation of interfacial strength. This might be due to the possibility that during TSV exposure, the deteriorated PCM at elevated temperature may restructure itself after cooling [76], resulting in less detrimental influence of seasonal variation than day–night variation exposure.
The outcome of higher interfacial strength (about 37%), as presented in Figure 8, and a smaller number of “(I)” fracture modes, as presented in Figure 9a, under TSV in modified PCM specimens suggested a positive influence of durability enhancement of silica fume with PCM as a repaired mortar. This might be attributed to the formation of more hydrogen bonds at the interface with a strong binding force, as observed in our previous study [30] and by generating a denser microstructure of the interface (micro-filler effect) due to the incorporation of extremely fine and reactive silica fume with PCM. Conclusively, silica fume improves the durability of the composite specimen under cyclic temperature conditions.

3.2. Influence of Moisture Content

3.2.1. Wetting and Drying Cycles

The composite specimens were exposed to a cycle of 2 days of wetting followed by 2 days of drying conditions to study the influence of simultaneous wetting and drying (W/D) conditions on the interfacial strength. One W/D cycle was completed in four days and the mechanical loading test was performed in wet conditions to evaluate the bonding strength after 0, 12, and 24 cycles of exposure. The interfacial strength was reduced further with the increase in the W/D cycles both in normal and modified PCM specimens, as presented in Figure 10a. About 11% strength reduction after the first W/D cycle and about 15% strength reduction after 12th W/D cycle considering normal PCM overlay material were observed in the previous study [75], indicating similar trends of strength reduction as observed in this study. As the interface is the most porous layer compared to the rest of the specimens, a higher degree of saturation at the interface degrades the mechanical properties and leads to a reduction in the bond strength [77]. The intensified pore water exerts pressure and generates micro-cracks during the external force application, subsequently degrading the strength. Absorbed water within the finest pores of cement gel also generates stress and lowers the energy barrier for bond rupture [73].
In the W/D cycle condition, moisture at the interface exerts water pressure, causing micro-cracks that deteriorate the interfacial bonding during continuous wetting and drying, resulting in a significant reduction in the bonding strength. The strength reduction was only about 15% in the modified PCM specimen, whereas it was more than 30% in the normal PCM specimen compared to its corresponding control specimens tested before any exposure condition (0 cycle). This is due to the higher level of moisture in the normal PCM–concrete interface that exerts pressure from inside during loading and increases the level of damage. To evaluate quantitatively the durability enhancement effect of silica fume, the bond strength with/without silica fume was compared under different W/D cycle exposure and presented in Figure 10b. In all exposure states of W/D cycles, the modified PCM specimens showed higher interfacial strength than normal PCM specimens. The use of silica fume reduces the porosity of the interface due to its extreme fineness, thus reducing the moisture presence in the void space. This will cause less presence of moisture in the void space and reduce the impact of water pressure during continuous W/D, thus decreasing the damage degradation under W/D cycles. In addition, the formation of more C-S-H with strong binding force with silica fume inclusion helps to acquire an adequate bond between the concrete substrate and repair material, thus reducing the damage initiation and propagation along the interface under W/D cycles.
The fracture mode under the influence of moisture is presented in Figure 11. The acronym designation adopted as follows: “N” or “M” refers to normal or modified PCM followed by exposure condition and exposure duration. For example, N_W/D_12C refers to normal PCM specimens exposed under wetting and drying conditions and tested after 12 cycles of exposure. Interface fracture (I) was the dominant fracture mode for normal PCM specimens irrespective of the number of W/D cycles, whereas the specimen with modified PCM exhibited only one “(I)” fracture and two composite, (I-P) or (I-C), fracture modes. As an example, the pictural view of the fracture surface after the loading test of the normal PCM [pure interface fracture (I)] and modified PCM specimen [composite mode fracture (I-C)] is shown in Figure 12a,b, respectively. A higher number of “(I)” fracture modes in normal PCM specimens than in modified PCM specimens indicates higher modified PCM overlay–concrete adhesion with better durability.

3.2.2. Continuous Immersion in Water

The composite specimens were immersed in water to study the influence of continuous immersion in water on the interfacial strength. The specimens were taken out of the curing tank after 48 and 96 days of exposure and the test was conducted immediately in wet conditions. The interfacial strength reduction of about 20% was observed after 96 days of exposure compared to control cases tested before any exposure condition (zero immersion day) of normal PCM specimens, whereas its effects were found marginal in modified PCM specimens, as presented in Figure 13a. The interfacial strength was within 6% of the strength of control specimens in the previous study [75] after 48 days of continuous immersion in water. Similar observations were also found in this study up to 48 days of exposure in normal PCM overlay material.
Extra moisture at the interface of normal PCM specimens due to higher porosity loosens the cohesion of the polymers by swelling and dissolving the polymer films, resulting in strength reduction [78]. This resulted in quite limited absorbed water at the modified PCM–concrete interface during continuous wetting due to the lowering of porosity with silica fume inclusion; thus, its effect on modified specimens is marginal. The durability enhancement effect of silica fume was evaluated after 0, 48, and 96 days of continuous wetting of with/without silica fume specimens, as presented in Figure 13b. The higher interfacial bonding strength in modified PCM than normal PCM specimens at all exposure states indicates that the exposure condition of continuous wetting has very little effect on the modified PCM–concrete interface than the normal PCM–concrete interface, which has a significant effect.
The fracture mode of all the specimens tested under the exposure of continuous immersion is shown in Figure 11. As an example, the pictural view of the fracture surface after the loading test of the normal and modified PCM specimen is presented in Figure 14a,b, respectively. The number of “(I)” fracture modes in modified PCM specimens was less than in normal PCM specimens, which indicates higher modified PCM overlay–concrete adhesion. This might be due to the fact that the environment for the proper hydration and curing improved for the silica fume modified PCM with the continuous immersion in water. In addition, free alkali after the hydration of cement reacts with the silica compound to form an additional C-S-H hydrate under the water-supplied condition, resulting in better bonding performance of the composite under continuous wetting conditions. Conclusively, the modified PCM is very important to achieve a good interfacial bond with concrete under continuous wetting.
The influence of moisture content after the same length of exposure under continuous immersion in water was observed to be lower than the W/D cycle conditions, as shown in Figure 15a,b. The hydration and curing environment improved for PAE PCM with the continuous immersion in water. In addition, in continuous immersion cases, the hydroxyl group in the concrete reacts to form an additional hydrogen bond with the PCM under continuous water supplied conditions [79]. Therefore, it gives extra overlay material–concrete adhesion and improved composite action of the repaired specimens.

3.3. Statistical Analysis

Statistical analyses of the experimental data of interfacial strength obtained from the loading test were performed using a one-way ANOVA. Significant criteria were imposed considering the F-value to evaluate the durability enhancement effect of silica fume PCM as a repair mortar under the influence of influencing factors (elevated temperature and moisture content) on the interface of both normal and modified PCM specimens. The details of the calculation process/formulas of the parameters of the ANOVA table, as shown in Table 4, are presented in the literature [80].
The degree of influence of the considered factor (elevated temperature and moisture under different head) were evaluated by comparing the calculated F-value using the ANOVA table and the critical F-value (Fx) obtained using F distribution at 1% (F0.01), 5% (F0.05), and 10% (F0.1) significance levels. The degree of influence of the considered factor can also be obtained from the p-value at different percentages of significance level. The significance criteria used in this research work are presented in Table 5.
The statistical analyses result of the experimental data using a one-way ANOVA is presented in Table 6 and Table 7 for the moisture content and elevated temperature, respectively. The critical F-value (Fx) was evaluated as 3.46, 5.14, and 10.92 using F distribution at 1% (F0.01), 5% (F0.05), and 10% (F0.1) significance levels, respectively. The calculated F-value for the normal PCM specimens under W/D cycle was 14.92, which was higher than the critical F-value [F0.1 (10.92)], indicating a highly significant effect of the exposure condition on the interfacial bonding strength. Similarly, the level of significance of the other exposure condition under moisture were obtained by comparing the calculated and critical F-value and tabulated in Table 6. The calculated F-value for the modified PCM specimens (5.17) under W/D cycle exposure was smaller than the normal PCM specimens (14.92). This confirmed that the exposure condition of W/D cycle has less effect on the modified PCM–concrete interface compared to the interface of normal PCM–concrete that have a highly significant effect under W/D cycle. The statistical analyses result also confirmed that the exposure condition of continuous wetting (Table 6) and elevated temperature (both constant and cyclic condition) (Table 7) has very little effect on the modified PCM–concrete interface compared to the interface of normal PCM–concrete, which has a significant effect. Conclusively, the statistical analysis results along with experimental data imply the positive influence of modified PCM as a repair material to achieve good interfacial bonding strength under both W/D cycle and continuous immersion in water.

4. Conclusions

The influence of elevated temperature fluctuation and moisture content on the PCM interfacial bonding strength with/without silica fume was investigated. Four temperature exposure conditions with a maximum temperature level of 60 °C to simulate short-duration, moderate-duration and cyclic (day–night and seasonal variation) conditions and two moisture content exposure conditions to simulate continuous immersion in water and simultaneous wetting and drying (W/D) cycle up to 96 days were investigated and the following conclusions can be drawn.
  • The concrete–PCM interfacial bond strength significantly reduces with the exposure at elevated temperature (60 °C).
  • The use of normal PCM (without silica fume) alone as an overlay material results in a higher percentage decrease in bond strength under both short-duration (3 days) and long-duration (30 days) exposure at constant 60 °C temperature. The combined use of PCM and silica fume significantly decreases the reduction percentage of bond strength. A delay in the occurrence of interface fracture (at higher load) and the higher number of specimen failures in composite fracture mode in modified PCM cases indicate higher concrete–overlay material adhesion with better durability under constant temperature exposure.
  • The reduction percentage further increases under day–night and seasonal variation exposure conditions, resulting in more detrimental influence of the cyclic elevated temperature on the interfacial bonding strength. The use of silica fume with PCM led to an optimal solution in terms of bond strength, PCM–concrete adhesion, thus improving the durability of the concrete–PCM interface under cyclic temperature conditions. Both W/D cycle and continuous immersion conditions have a significant effect on the bond properties of the concrete-to-normal PCM interface. Compared to normal PCM mortar, however, use of modified silica PCM mortar significantly improves bond strength and led to more ductile failure due to the multiple cracking behavior, which dispersed more uniformly the shear stress transfer at the concrete–PCM interface under moisture content exposure.
  • The influence of moisture content after the same length of exposure under continuous immersion results in lower a reduction in PCM interfacial strength with and without silica fume compared to the exposure under wetting and drying cycle.
The concrete–PCM interface is the most critical component in the PCM overlaying method. To evaluate the overall performance of the strengthened structures, it is necessary to consider the effects of environmental degradation on the interface. The obtained data confirm the suitability of the PCM overlaying method with silica fume under harsh environments as it provides adequate concrete–overlay material bond and enhances adhesion and durability under elevated temperature and moisture. However, the results from this study are restrained to a limited duration of exposure. Additional data should be developed with a longer duration of exposure of about 2–3 years in the future to infer longer-term applicability and to predict the service life of strengthened structures accurately under harsh environmental conditions.

Author Contributions

Conceptualization, M.H.M. and K.M.; methodology, M.H.M. and K.M.; software, M.H.M.; validation, M.H.M. and K.M.; formal analysis, M.H.M.; investigation, M.H.M.; resources, M.H.M.; data curation, M.H.M.; writing—original draft preparation, M.H.M.; writing—review and editing, M.H.M. and K.M.; visualization, M.H.M.; supervision, K.M.; project administration, K.M.; funding acquisition, K.M. All authors have read and agreed to the published version of the manuscript.

Funding

This research was partially funded by the Japan Society for the promotion of Science (JSPS), Project code—20J2085401.

Institutional Review Board Statement

Not applicable.

Data Availability Statement

All data generated or used during the study appear in the submitted article.

Acknowledgments

The authors would like to acknowledge the scholarship grant provided by the Japan Society for the promotion of Science (JSPS) under the “Research Fellowship for Young Scientists, Project code—20J2085401” program. The authors are also grateful to Denka Company limited for providing valuable advice and materials (polymer cement mortar and silica fume) for this research.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Liu, J.; Wang, D. Influence of Steel Slag-Silica Fume Composite Mineral Admixture on the Properties of Concrete. Powder Technol. 2017, 320, 230–238. [Google Scholar] [CrossRef]
  2. Choi, S.J.; Bae, S.H.; Lee, J.I.; Bang, E.J.; Ko, H.M. Strength, Carbonation Resistance, and Chloride-Ion Penetrability of Cement Mortars Containing Catechol-Functionalized Chitosan Polymer. Materials 2021, 14, 6395. [Google Scholar] [CrossRef] [PubMed]
  3. Jo, B.W.; Park, S.K.; Park, J.C. Mechanical Properties of Polymer Concrete Made with Recycled PET and Recycled Concrete Aggregates. Constr. Build. Mater. 2015, 195, 2191–2198. [Google Scholar] [CrossRef]
  4. Jafari, K.; Tabatabaeian, M.; Joshaghani, A.; Ozbakkaloglu, T. Optimizing the Mixture Design of Polymer Concrete: An Experimental Investigation. Constr. Build. Mater. 2018, 167, 185–196. [Google Scholar] [CrossRef]
  5. Ferdous, W.; Manalo, A.; Wong, H.S.; Abousnina, R.; AlAjarmeh, O.S.; Zhuge, Y.; Schubel, P. Optimal Design for Epoxy Polymer Concrete Based on Mechanical Properties and Durability Aspects. Constr. Build. Mater. 2020, 232, 117229. [Google Scholar] [CrossRef]
  6. Choi, S.-J.; Bae, S.-H.; Lee, J.-I.; Bang, E.J.; Choi, H.Y.; Ko, H.M. Effect of Bio-Inspired Polymer Types on Engineering Characteristics of Cement Composites. Polymers 2022, 14, 1808. [Google Scholar] [CrossRef] [PubMed]
  7. Manjunatha, M.; Dinesh, S.; Balaji, K.V.G.D.; Bharath, A. Engineering properties and environmental impact assessment of green concrete prepared with PVC waste powder: A step towards sustainable approach. Case Stud. Constr. Mater. 2022, 17, e01404. [Google Scholar] [CrossRef]
  8. Reshma, T.V.; Manjunatha, M.; Bharath, A.; Ranjitha, B.T.; Jagadish, V.; Manjunatha, L.R. Influence of ZnO and TiO2 on mechanical and durability properties of concrete prepared with and without polypropylene fibers. Materialia 2021, 18, 101138. [Google Scholar] [CrossRef]
  9. Hassan, K.E.; Brooks, J.J.; Al-Alawi, L. Compatibility of repair mortars with concrete in a hot-dry environment. Cem. Concr. Compos. 2001, 23, 93–101. [Google Scholar] [CrossRef]
  10. Al-Zahrani, M.M.; Maslehuddin, M.; Al-Dulaijan, S.U.; Ibrahim, M. Mechanical properties and durability characteristics of polymer and cement-based repair materials. Cem. Concr. Compos. 2003, 25, 527–537. [Google Scholar] [CrossRef]
  11. Chung, D.D.L. Use of polymers for cement-based structural materials. J. Mater. Sci. 2004, 39, 2973–2978. [Google Scholar] [CrossRef]
  12. Yang, Z.X.; Shi, X.M.; Creighton, A.T.; Peterson, M.M. Effect of styrene-butadiene rubber latex on the chloride permeability and microstructure of Portland cement mortar. Constr. Build. Mater. 2009, 23, 2283–2290. [Google Scholar] [CrossRef]
  13. Park, D.C.; Ahn, J.C.; Oh, S.G.; Song, H.C.; Noguchi, T. Drying effect of polymer-modified cement for patch-repaired mortar on constraint stress. Constr. Build. Mater. 2009, 23, 434–447. [Google Scholar] [CrossRef]
  14. Wang, R.; Wang, P.M. Function of styrene-acrylic ester copolymer latex in cement mortar. Mater. Struct. 2010, 43, 443–451. [Google Scholar] [CrossRef]
  15. Khan, K.A.; Ahmad, I.; Alam, M. Effect of ethylene vinyl acetate (EVA) on the setting time of cement at different temperatures as well as on the mechanical strength of concrete. Arab. J. Sci. Eng. 2019, 44, 4075–4084. [Google Scholar] [CrossRef]
  16. Satoh, K.; Hizukuri, M.; Hida, K.; Hikichi, K. Strengthening effect of strengthened RC slab of highway bridge using polymer cement mortar shot bottom side thickening method. Proc. Jpn. Concr. Inst. 2000, 22, 517–522. [Google Scholar]
  17. Mirza, J.; Mirza, M.S.; Lapointe, R. Laboratory and field performance of polymer-modified cement-based repair mortars in cold climates. Constr. Build. Mater. 2002, 16, 365–374. [Google Scholar] [CrossRef]
  18. Espeche, A.D.; León, J. Estimation of bond strength envelopes for old-to-new concrete interfaces based on a cylinder splitting test. Constr. Build. Mater. 2011, 25, 1222–1235. [Google Scholar] [CrossRef]
  19. Satoh, K.; Kodama, K. Central peeling failure behavior of polymer cement mortar retrofitting of reinforced concrete beam. J. Mater. Civ. Eng. 2005, 17, 126–136. [Google Scholar] [CrossRef]
  20. Zhang, D.; Ueda, T.; Furuuchi, H. Intermediate Crack Debonding of Polymer Cement Mortar Overlay-Strengthened RC Beam. J. Mater. Civ. Eng. 2011, 23, 857–865. [Google Scholar] [CrossRef]
  21. Zhang, D.; Ueda, T.; Furuuchi, H. Concrete cover separation failure of overlay-strengthened reinforced concrete beams. Constr. Build. Mater. 2012, 26, 735–745. [Google Scholar] [CrossRef]
  22. Abdellatief, M.; Alanazi, H.; Radwan, M.K.H.; Tahwia, A.M. Multiscale Characterization at Early Ages of Ultra-High Performance Geopolymer Concrete. Polymers 2022, 14, 5504. [Google Scholar] [CrossRef] [PubMed]
  23. Mehta, A.; Ashish, D.K. Silica fume and waste glass in cement concrete production: A review. J. Build. Eng. 2020, 29, 100888. [Google Scholar] [CrossRef]
  24. Lakhiar, M.T.; Kong, S.Y.; Bai, Y.; Susilawati, S.; Zahidi, I.; Paul, S.C.; Raghunandan, M.E. Thermal and Mechanical Properties of Concrete Incorporating Silica Fume and Waste Rubber Powder. Polymers 2022, 2022, 4858. [Google Scholar] [CrossRef] [PubMed]
  25. Keerio, M.A.; Abbasi, S.A.; Kumar, A.; Bheel, N.; Rehaman, K.U.; Tashfeen, M. Effect of Silica Fume as Cementitious Material and Waste Glass as Fine Aggregate Replacement Constituent on Selected Properties of Concrete. Silicon 2020, 14, 165–176. [Google Scholar] [CrossRef]
  26. Gao, J.M.; Qian, C.X.; Wang, B.; Morino, K. Experimental study on properties of polymer-modified cement mortars with silica fume. Cem. Concr. Res. 2002, 32, 41–45. [Google Scholar] [CrossRef]
  27. Alessandra, A.E.F.D.S.; Sichieri, E.P. Experimental study on polymer-modified mortars with silica fume applied to fix porcelain tile. Build. Environ. 2007, 42, 2645–2650. [Google Scholar]
  28. Hayato, S.; Mizan, M.H.; Tamon, U.; Katsuichi, M.; Jun, T. A study on effect of silica fume and surface penetrant on bonding strength for overlaying. J. Asian Concr. Fed. 2019, 5, 1–14. [Google Scholar]
  29. Mizan, M.H.; Ueda, T.; Matsumoto, K. Enhancement of the concrete-PCM interfacial bonding strength using silica fume. Constr. Build. Mater. 2020, 259, 119774. [Google Scholar] [CrossRef]
  30. Mizan, M.H.; Matsumoto, K. Studying the Influence of Silica Fume on Bond Strength of the PCM-Concrete Interface under Shear Stress Condition. J. Mater. 2022, 15, 1473. [Google Scholar] [CrossRef]
  31. Kim, J.; Moon, J.H.; Shim, J.W.; Sim, J.; Lee, H.G.; Zi, G. Durability properties of a concrete with waste glass sludge exposed to freeze-and-thaw condition and deicing salt. Constr. Build. Mater. 2014, 66, 398–402. [Google Scholar] [CrossRef]
  32. Carlos, R.; Lima, P.R.; Ribeiro, D.V. Effect of Temperature on Mechanical Behavior of Concrete Reinforced with Different Types of GFRP Bar. Polymers 2022, 14, 3437. [Google Scholar]
  33. Patil, S.; Somasekharaiah, H.; Rao, H.S.; Ghorpade, V.G. Durability and micro-structure studies on fly ash and silica fume based composite fiber reinforced high-performance concrete. Mater. Today Proc. 2022, 49, 1511–1520. [Google Scholar] [CrossRef]
  34. Zhao, Z.; Li, W.; Shi, H.; Li, Z.; Li, J.; Zhao, C.; Wang, P. Strength of Coarse-Grained Soil Stabilized by Poly (Vinyl Alcohol) Solution and Silica Fume under Wet–Dry Cycles. Polymers 2022, 14, 3555. [Google Scholar] [CrossRef]
  35. Zhang, P.; Li, Q. Effect of polypropylene fiber on durability of concrete composite containing fly ash and silica fume. Compos. Part B Eng. 2013, 45, 1587–1594. [Google Scholar] [CrossRef]
  36. Zhang, Z.; Ji, Y.; Ji, W. Durability Performance Investigation for Engineering Fiber Cementitious Composites (ECC): Review. Polymers 2023, 15, 931. [Google Scholar] [CrossRef]
  37. Liu, J.; Li, X.; Saffari, P.; Liang, Q.; Li, L.; Chen, W. Developing a Polypropylene Fabric, Silica Fume, and Redispersible Emulsion Powder Cementitious Composite for Dynamic Water Environment. Polymers 2019, 11, 47. [Google Scholar] [CrossRef]
  38. Qian, Y.; Zhang, D.; Ueda, T. Interfacial Tensile Bond between Substrate Concrete and Repairing Mortar under Freeze-Thaw Cycles. J. Adv. Concr. Technol. 2016, 14, 421–432. [Google Scholar] [CrossRef]
  39. Jun, T.; Xiaowei, W.; Yu, Z.; Shaowei, H.; Wei, R.; Yinfei, D.; Wenwei, W.; Can, S.; Jie, M.; Yuxiao, Y. Investigation of damage behaviors of ECC-to-concrete interface and damage prediction model under salt freeze-thaw cycles. Constr. Build. Mater. 2019, 226, 238–249. [Google Scholar]
  40. Ali, S.; Reza, K.K. Bonding durability of polymer-modified concrete repair overlays under freeze–thaw conditions. Mag. Concr. Res. 2017, 69, 1268–1275. [Google Scholar]
  41. Rashid, K.; Ueda, T.; Zhang, D.; Miyaguchi, K.; Nakai, H. Experimental and analytical investigations on the behavior of interface between concrete and polymer cement mortar under hygrothermal conditions. Constr. Build. Mater. 2015, 94, 414–425. [Google Scholar] [CrossRef]
  42. Rashid, K.; Ueda, T.; Zhang, D.; Miyaguchi, K. Study on influence of temperature on bond integrity between polymer cement mortar and concrete. In Proceedings of the International Conference on Advances in Construction Materials, Whistler, BC, Canada, 19–21 August 2015. [Google Scholar]
  43. Tamon, U.; Rashid, K.; Ye, Q.; Dawei, Z. Effects of temperature and moisture on concrete-PCM interface performance. Sustain. Civ. Eng. Struct. Constr. Mater. 2017, 171, 71–79. [Google Scholar] [CrossRef]
  44. Ueda, T.; Justin, S.; Rashid, K. Moisture and temperature effects on interface mechanical properties for external bonding. In Proceedings of the 5th International Conference on Durability of Concrete Structures, Shenzhen, China, 30 June–1 July 2016; pp. 1–12. [Google Scholar]
  45. Ueda, T.; Justin, S.; Rashid, K.; Qian, Y.; Zhang, D. Long-Term Performance of External Bonding under Moisture and Temperature Effects; Springer: Berlin/Heidelberg, Germany, 2018; pp. 1867–1876. [Google Scholar]
  46. Al-Jabri, K.S.; Hago, A.W.; Al-Nuaimi, A.S.; Al-Saidy, A.H. Concrete blocks for thermal insulation in hot climate. Cem. Concr. Res. 2005, 35, 1472–1479. [Google Scholar] [CrossRef]
  47. Al-Gahtani, A.S.R.; AI-Mussallam, A.A. Performance of repair materials exposed to fluctuation of temperature. J. Mater. Civ. Eng. 1995, 7, 9–18. [Google Scholar] [CrossRef]
  48. Henry, M.; Darma, I.S.; Sugiyama, T. Analysis of the effect of heating and re-curing on the microstructure of high strength concrete using X-ray CT. Constr. Build. Mater. 2014, 67, 37–46. [Google Scholar] [CrossRef]
  49. Luo, X.; Sun, W.; Chan, Y.N. Residual compressive strength and microstructure of high performance concrete after exposure to high temperature. Mater. Struct. 2012, 33, 294–298. [Google Scholar] [CrossRef]
  50. Akca, A.H.; Ozyurt, N. Effects of re-curing on microstructure of concrete after high temperature exposure. Constr. Build. Mater. 2018, 168, 431–441. [Google Scholar] [CrossRef]
  51. Chang, Y.F.; Chen, Y.H.; Sheu, M.S.; Yao, G.C. Residual stress–strain relationship for concrete after exposure to high temperatures. Cem. Concr. Res. 2006, 36, 1999–2005. [Google Scholar] [CrossRef]
  52. Chen, B.; Li, C.; Chen, L. Experimental study of mechanical properties of normal-strength concrete exposed to high temperatures at an early age. Fire Saf. J. 2009, 44, 997–1002. [Google Scholar] [CrossRef]
  53. Zhai, Y.; Deng, Z.; Li, N.; Xu, R. Study on compressive mechanical capabilities of concrete after high temperature exposure and thermo-damage constitutive model. Constr. Build. Mater. 2014, 68, 777–782. [Google Scholar] [CrossRef]
  54. Ries, M.L. Effect of Temperature on the Mechanical Properties of Polymer Mortars. Mater. Res. 2012, 15, 645–649. [Google Scholar] [CrossRef]
  55. Hassan, K.E.; Robery, P.C.; Al-Alawi, L. Effect of hot-dry curing environment on the intrinsic properties of repair materials. Cem. Concr. Compos. 2009, 22, 453–458. [Google Scholar] [CrossRef]
  56. Rashid, K.; Zhang, D.; Ueda, T.; Weiliang, J. Investigation on concrete-PCM interface under elevated temperature: At material level and member level. Constr. Build. Mater. 2016, 125, 465–478. [Google Scholar] [CrossRef]
  57. Rashid, K.; Zhang, D.; Ueda, T. Influence of primer on bond integrity between concrete-polymer cement mortar at elevated temperature: In tension, shear and moment. Pak. J. Eng. Appl. Sci. 2017, 20, 94–101. [Google Scholar]
  58. Rashid, K.; Ueda, T.; Zhang, D. Study on Shear Behavior of Concrete-polymer Cement Mortar at Elevated Temperature. Civ. Eng. Dimens. 2016, 18, 93–102. [Google Scholar] [CrossRef]
  59. Zhang, D.; Rashid, K.; Wang, B.; Ueda, T. Experimental and analytical investigation of crack spacing and width for overlaid RC beams at elevated temperatures. J. Struct. Eng. 2017, 143, 04017168. [Google Scholar] [CrossRef]
  60. Kanezuka, T.; Ito, M.; Katori, K. Fresh State, Strength, and Structure System by Changing the Ratio of Mixing Silica Fume; An Investigation by SOC Group: Tokyo, Japan, 2005. [Google Scholar]
  61. Ohama, Y. Handbook of Polymer-Modified Concrete and Mortars-Properties and Process Technology; Noyes Publications: Park Ridge, NJ, USA, 1995. [Google Scholar]
  62. Sahmaran, M.; Yücel, H.E.; Yildirim, G. Investigation of the bond between the concrete substrate and ECC overlays. J. Mater. Civ. Eng. 2013, 26, 167–174. [Google Scholar] [CrossRef]
  63. Wang, B.; Xu, S.; Liu, F. Evaluation of tensile bonding strength between UHTCC repair materials and concrete substrate. Constr. Build. Mater. 2016, 112, 595–606. [Google Scholar] [CrossRef]
  64. Yu, J.T.; Xu, W.L.; Zhang, Y.M. Experiment study on fracture property of ECC-concrete interface. J. Build. Mater. Struct. 2015, 18, 958–963. [Google Scholar]
  65. ASTM C 39-03; Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens. ASTM International: West Conshohocken, PA, USA, 2003.
  66. Santos, P.M.D.; Júlio, E.B.S. Recommended improvements to current shear friction provisions of model code. In Proceedings of the 3rd FIB International Congress, Washington, DC, USA, 29 May–2 June 2010. [Google Scholar]
  67. Santos, P.M.D.; Júlio, E.N.B.S. A state-of-the-art review of roughness quantification methods for concrete surfaces. Constr. Build. Mater. 2013, 38, 912–923. [Google Scholar] [CrossRef]
  68. Momayez, A.; Ramezanianpour, A.; Rajaie, H.; Ehsani, M.R. Bi-Surface Shear Test for Evaluating Bond between Existing and New Concrete. ACI Mater. J. 2004, 101, 99–106. [Google Scholar]
  69. Tanaka, H.; Yoshitake, I.; Yamaguchi, Y.; Hamada, S. A study of prototype of simple loading device giving pure shear force. Proc. Jpn. Concr. Inst. 2003, 25, 1003–1008. [Google Scholar]
  70. Rashid, K.; Wang, Y.; Ueda, T. Influence of continuous and cyclic temperature durations on the performance of polymer cement mortar and its composite with concrete. Compos. Struct. 2019, 215, 214–225. [Google Scholar] [CrossRef]
  71. Xie, H.; Li, G.; Xiong, G. Microstructure model of the interfacial zone between fresh and old concrete. J. Wuhan Univ. Technol.-Mater. Sci. Ed. 2002, 17, 64–68. [Google Scholar]
  72. Galle, C. Effect of drying on cement-based materials pore structure as identified by mercury intrusion porosimetry: A comparative study between oven-, vacuum-, and freeze-drying. Cem. Concr. Res. 2001, 31, 1467–1477. [Google Scholar] [CrossRef]
  73. Bazant, P.; Kaplan, F.M. Effect of Temperature and Humidity on fracture Energy of Concrete. ACI Mater. J. 1988, 85, 262–271. [Google Scholar]
  74. Biswas, M.; Kelsey, R.G. Failure model of polymer Mortar. J. Eng. Mech. 1991, 117, 1088–1104. [Google Scholar] [CrossRef]
  75. Rashid, K. Behaviour of Interface between Concrete-PCM at Elevated Temperature at Material and Member Level. Ph.D. Thesis, Hokkaido University, Sapporo, Japan, 2016. [Google Scholar]
  76. Divya, R.S.; Santhanam, M. Influence of moderately elevated temperatures on engineering properties of concrete used for nuclear reactor vaults. Cem. Concr. Compos. 2012, 34, 917–923. [Google Scholar] [CrossRef]
  77. Shoukry, S.N.; William, G.W.; Downie, B.; Riad, M.Y. Effect of moisture and temperature on the mechanical properties of concrete. Constr. Build. Mater. 2011, 25, 688–696. [Google Scholar] [CrossRef]
  78. Knapen, E.; Gemert, D.V. Effect of under water storage on bridge formation by water-soluble polymers in cement mortars. Constr. Build. Mater. 2009, 23, 3420–3425. [Google Scholar] [CrossRef]
  79. Chen, C.H.; Huang, R.; Wu, J.K. Influence of soaking and polymerization conditions on the properties of polymer concrete. Constr. Build. Mater. 2006, 20, 706–712. [Google Scholar] [CrossRef]
  80. Li, K.; Wei, Z.; Qiaou, H.; Lu, C.; Theogene, H. PCM-Concrete Interfacial Tensile Behavior Using Nano-SiO2 Based on Splitting-Tensile Test. J. Adv. Concr. Technol. 2021, 19, 321–334. [Google Scholar] [CrossRef]
Figure 1. Preparation of composite specimens. (a) Rough concrete surface preparation. (b) PCM mixing using a hand mixer. (c) Casting of PCM in two layers.
Figure 1. Preparation of composite specimens. (a) Rough concrete surface preparation. (b) PCM mixing using a hand mixer. (c) Casting of PCM in two layers.
Polymers 15 02061 g001
Figure 2. Exposure condition used to investigate the effect of elevated temperature. (a) TSD. (b) TMD. (c) TDN. (d) TSV.
Figure 2. Exposure condition used to investigate the effect of elevated temperature. (a) TSD. (b) TMD. (c) TDN. (d) TSV.
Polymers 15 02061 g002
Figure 3. Exposure condition used for W/D cycles and continuous immersion in water.
Figure 3. Exposure condition used for W/D cycles and continuous immersion in water.
Polymers 15 02061 g003
Figure 4. Schematic of the test method used in this research work (unit: mm).
Figure 4. Schematic of the test method used in this research work (unit: mm).
Polymers 15 02061 g004
Figure 5. Bond strength of the composite specimens under constant elevated-temperature exposure.
Figure 5. Bond strength of the composite specimens under constant elevated-temperature exposure.
Polymers 15 02061 g005
Figure 6. Possible fracture modes of the composite specimens. (a) Concrete cohesion (C). (b) Composite fracture (I-C). (c) Adhesive interface (I). (d) Composite fracture (C-P). (e) Composite fracture (I-P).
Figure 6. Possible fracture modes of the composite specimens. (a) Concrete cohesion (C). (b) Composite fracture (I-C). (c) Adhesive interface (I). (d) Composite fracture (C-P). (e) Composite fracture (I-P).
Polymers 15 02061 g006
Figure 7. Fracture mode under constant elevated-temperature exposure. (a) Fracture mode. (b) Pure interface fracture (I) under TMD. (c) Composite fracture mode (C-P) under TSD.
Figure 7. Fracture mode under constant elevated-temperature exposure. (a) Fracture mode. (b) Pure interface fracture (I) under TMD. (c) Composite fracture mode (C-P) under TSD.
Polymers 15 02061 g007
Figure 8. Bond strength under cyclic elevated-temperature exposure.
Figure 8. Bond strength under cyclic elevated-temperature exposure.
Polymers 15 02061 g008
Figure 9. Fracture mode under cyclic temperature exposure (TDN and TSV). (a) Fracture mode under TDN and TSV. (b) Pure interface fracture (I) under TDN. (c) Composite mode fracture (I-P) under TDN.
Figure 9. Fracture mode under cyclic temperature exposure (TDN and TSV). (a) Fracture mode under TDN and TSV. (b) Pure interface fracture (I) under TDN. (c) Composite mode fracture (I-P) under TDN.
Polymers 15 02061 g009
Figure 10. Bonding strength under moisture content (W/D cycles). (a) Degradation of interfacial strength. (b) Influence of silica fume inclusion.
Figure 10. Bonding strength under moisture content (W/D cycles). (a) Degradation of interfacial strength. (b) Influence of silica fume inclusion.
Polymers 15 02061 g010
Figure 11. Fracture mode under influence of moisture.
Figure 11. Fracture mode under influence of moisture.
Polymers 15 02061 g011
Figure 12. Sample fracture mode of the composite specimen under W/D cycle exposure. (a) Pure interface fracture (I) mode. (b) Composite fracture (I-C) mode.
Figure 12. Sample fracture mode of the composite specimen under W/D cycle exposure. (a) Pure interface fracture (I) mode. (b) Composite fracture (I-C) mode.
Polymers 15 02061 g012
Figure 13. Bonding strength under moisture (continuous wetting). (a) Degradation of interfacial strength. (b) Influence of silica fume inclusion.
Figure 13. Bonding strength under moisture (continuous wetting). (a) Degradation of interfacial strength. (b) Influence of silica fume inclusion.
Polymers 15 02061 g013
Figure 14. Sample fracture mode of the composite specimen under continuous wetting conditions. (a) Composite fracture (I-P) mode. (b) Pure interface fracture (I) mode.
Figure 14. Sample fracture mode of the composite specimen under continuous wetting conditions. (a) Composite fracture (I-P) mode. (b) Pure interface fracture (I) mode.
Polymers 15 02061 g014
Figure 15. Influence of exposure types under moisture content on interfacial bond strength: (a) 48 days of exposure and (b) 96 days of exposure.
Figure 15. Influence of exposure types under moisture content on interfacial bond strength: (a) 48 days of exposure and (b) 96 days of exposure.
Polymers 15 02061 g015
Table 1. Mix proportion of one cubic meter of substrate concrete.
Table 1. Mix proportion of one cubic meter of substrate concrete.
W/C
(%)
Amount (kg/m3)Air-Entraining Agent
(mL/m3)
Compressive Strength (MPa)
WaterCementFine AggregateCoarse AggregateWater Reducer
4016040081810188187.541.6
Table 2. Mix proportion of repair material.
Table 2. Mix proportion of repair material.
Overlay MaterialWater/PCM
(%)
Silica Fume
(% of PCM Mass)
Superplasticizer
(% of PCM Mass)
Normal PCM 15.000
Modified 5% silica PCM 15.051
Table 3. Summary of exposure conditions and the number of specimens.
Table 3. Summary of exposure conditions and the number of specimens.
Specimen LevelOverlay Constituents
Normal PCMModified 5% Silica PCM
Exposure conditionsElevated temperature
(Series-I)
0 dayTCon33
3 daysTSD33
36 daysTMD33
30 cycleTDN33
12 cycleTSV33
Moisture content
(Series-II)
0 cycle W/D cycle33
12 cycle33
24 cycle33
0 dayContinuous immersion33
48 days33
96 days33
Table 4. Calculation procedure of one-way ANOVA.
Table 4. Calculation procedure of one-way ANOVA.
Source of VariationSum of Squares Deviation (SS)Degree of Freedom (DF)Mean Square Deviations (MS)F-Value
Between groupsSAr-1MSA = SA/(r-1)MSA/MSE
Within groupsSEn-rMSE = SE/(n-r)
Total varianceSTn-1
Note: “r” refers to levers number of influencing factor, and “n” refers to the total outcomes of different levers for influencing factor.
Table 5. Significant criteria of each influencing factors.
Table 5. Significant criteria of each influencing factors.
CriteriaResult
If F > F0.01 (r-1,n-r)Highly significant effect
If F0.01 (r-1,n-r) > F > F0.05 (r-1,n-r) Significant effect
If F0.05 (r-1,n-r) > F > F0.1 (r-1,n-r) Little effect
If F < F0.10 (r-1,n-r)No or very little effect
Table 6. Statistical analysis to evaluate the influence of moisture content under different heads.
Table 6. Statistical analysis to evaluate the influence of moisture content under different heads.
Factors and Exposure ConditionsInterfacial Shear Strength (MPa)SSDFMSF-ValueFxLevel of Significance
W/D cyclesNPCM0 cycle5.604.276.055.9815.9814.92F0.1 = 3.46
F0.05 = 5.14
F0.01 = 10.92
Highly significant
12 cycle3.903.363.612.8070.40
24 cycle3.283.373.27------
SPCM0 cycle6.276.305.112.7012.705.17Significant
12 cycle4.526.055.293.6670.52
24 cycle5.474.463.72------
Continuous immersionNPCM0 day5.604.276.055.2015.209.92Significant
48 days3.933.924.783.6770.53
96 days4.143.672.51------
SPCM0 day6.276.305.110.0710.070.31No or very little
48 days5.416.225.631.4670.21
96 days5.485.546.03------
Note: “NPCM” denotes normal PCM specimens, and “SPCM” denotes modified 5% silica PCM specimens.
Table 7. Statistical analysis to evaluate the influence of elevated temperature under different heads.
Table 7. Statistical analysis to evaluate the influence of elevated temperature under different heads.
Factors and Exposure ConditionsInterfacial Shear Strength (MPa)SSDFMSF-ValueFxLevel of Significance
Constant temperature ExposureNPCMTCON5.604.276.053.1413.148.07F0.1 = 3.46
F0.05 = 5.14
F0.01 = 10.92
Significant
TSD6.513.934.072.7270.39
TMD3.833.474.28------
SPCMTCON6.276.305.111.4411.443.62No or very little
TSD6.045.574.622.8070.40
TMD4.504.585.65------
Cyclic temperature NPCMTCON5.604.276.053.8013.805.59Significant
TDN3.423.973.114.7570.68
TSV4.083.993.07------
SPCMTCON6.276.305.110.9510.950.31No or very little
TDN4.605.392.501.7770.25
TSV5.035.255.01------
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Mizan, M.H.; Matsumoto, K. Durability Enhancement Effect of Silica Fume on the Bond Behavior of Concrete–PCM Composites under Environmental Conditions. Polymers 2023, 15, 2061. https://0-doi-org.brum.beds.ac.uk/10.3390/polym15092061

AMA Style

Mizan MH, Matsumoto K. Durability Enhancement Effect of Silica Fume on the Bond Behavior of Concrete–PCM Composites under Environmental Conditions. Polymers. 2023; 15(9):2061. https://0-doi-org.brum.beds.ac.uk/10.3390/polym15092061

Chicago/Turabian Style

Mizan, Mahmudul Hasan, and Koji Matsumoto. 2023. "Durability Enhancement Effect of Silica Fume on the Bond Behavior of Concrete–PCM Composites under Environmental Conditions" Polymers 15, no. 9: 2061. https://0-doi-org.brum.beds.ac.uk/10.3390/polym15092061

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop