Correction

Correction: Borecka et al. Development of the Latanoprost Solid Delivery System Based on Poly(l-lactide-co-glycolide-co-trimethylene carbonate) with Shape Memory for Glaucoma Treatment. Appl. Sci. 2023, 13, 7562

1
Centre of Polymer and Carbon Materials, Polish Academy of Sciences, M. Curie-Skłodowskiej 34, 41-819 Zabrze, Poland
2
Department of Biotechnology and Genetic Engineering, Faculty of Pharmaceutical Sciences in Sosnowiec, Medical University of Silesia, Katowice, Jedności 8, 41-200 Sosnowiec, Poland
3
Chair and Department of Biopharmacy, Faculty of Pharmaceutical Sciences in Sosnowiec, Medical University of Silesia, Katowice, Jedności 8, 41-200 Sosnowiec, Poland
4
Department of Mechanics, Materials and Biomedical Engineering, Faculty of Mechanical Engineering, Wrocław University of Science and Technology, Wybrzeże Wyspiańskiego 27, 50-370 Wrocław, Poland
5
Department of Experimental Pharmacology, Mossakowski Medical Research Centre, Polish Academy of Sciences, A. Pawińskiego 5, 02-106 Warsaw, Poland
*
Author to whom correspondence should be addressed.
Submission received: 29 November 2023 / Accepted: 30 November 2023 / Published: 7 December 2023
(This article belongs to the Special Issue Advances in Biomaterials and Drug Technology)
In the original publication [1], there was a mistake in Table 3 as published. The commas and periods for numbers are not in the correct place. The corrected Table 3 appears below. The authors state that the scientific conclusions are unaffected. This correction was approved by the Academic Editor. The original publication has also been updated.

Reference

  1. Borecka, A.; Rech, J.; Janeczek, H.; Wilińska, J.; Kasperczyk, J.; Kobielarz, M.; Grieb, P.; Turek, A. Development of the Latanoprost Solid Delivery System Based on Poly(l-lactide-co-glycolide-co-trimethylene carbonate) with Shape Memory for Glaucoma Treatment. Appl. Sci. 2023, 13, 7562. [Google Scholar] [CrossRef]
Table 3. Heterogeneity, circularity, and solidity of the surface of P(l-LA:GA:TMC) matrix-LTP and EB-P(l-LA:GA:TMC) matrix-LTP during degradation, calculated using ImageJ®.
Table 3. Heterogeneity, circularity, and solidity of the surface of P(l-LA:GA:TMC) matrix-LTP and EB-P(l-LA:GA:TMC) matrix-LTP during degradation, calculated using ImageJ®.
P(l-LA:GA:TMC) Matrix-LTP
Time (Days)Area (µm2)Heterogeneity (%)CircularitySolidity
04,796.116.50.0390.81
14,454.817.40.1370.82
154,739.129.70.3520.75
294,364.128.90.3490.78
434,677.241.30.6840.51
574,673.853.30.4910.45
714,678.258.40.4140.50
854,220.969.00.1620.31
994,772.566.10.1420.35
1134,564.281.70.6520.19
EB-P(l-LA:GA:TMC) Matrix-LTP
Time (Days)Area (µm2)Heterogeneity (%)CircularitySolidity
04,583.716.80.0360.83
14,671.816.70.0370.83
154,096.138.80.4990.74
294,568.238.60.4160.75
434,091.438.50.2100.75
574,527.138.70.2020.73
714,884.063.60.1520.49
854,628.560.70.5620.43
994,844.768.50.1470.29
1134,533.178.70.7190.21
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Borecka, A.; Rech, J.; Janeczek, H.; Wilińska, J.; Kasperczyk, J.; Kobielarz, M.; Grieb, P.; Turek, A. Correction: Borecka et al. Development of the Latanoprost Solid Delivery System Based on Poly(l-lactide-co-glycolide-co-trimethylene carbonate) with Shape Memory for Glaucoma Treatment. Appl. Sci. 2023, 13, 7562. Appl. Sci. 2023, 13, 13043. https://0-doi-org.brum.beds.ac.uk/10.3390/app132413043

AMA Style

Borecka A, Rech J, Janeczek H, Wilińska J, Kasperczyk J, Kobielarz M, Grieb P, Turek A. Correction: Borecka et al. Development of the Latanoprost Solid Delivery System Based on Poly(l-lactide-co-glycolide-co-trimethylene carbonate) with Shape Memory for Glaucoma Treatment. Appl. Sci. 2023, 13, 7562. Applied Sciences. 2023; 13(24):13043. https://0-doi-org.brum.beds.ac.uk/10.3390/app132413043

Chicago/Turabian Style

Borecka, Aleksandra, Jakub Rech, Henryk Janeczek, Justyna Wilińska, Janusz Kasperczyk, Magdalena Kobielarz, Paweł Grieb, and Artur Turek. 2023. "Correction: Borecka et al. Development of the Latanoprost Solid Delivery System Based on Poly(l-lactide-co-glycolide-co-trimethylene carbonate) with Shape Memory for Glaucoma Treatment. Appl. Sci. 2023, 13, 7562" Applied Sciences 13, no. 24: 13043. https://0-doi-org.brum.beds.ac.uk/10.3390/app132413043

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop