Next Article in Journal
Evaluation of the Coupling of a Hybrid Power Plant with a Water Generation System
Next Article in Special Issue
Stressing State Analysis on a Single Tube CFST Arch Under Spatial Loads
Previous Article in Journal
Investigation of the Functional Decline in Proprioceptors for Low Back Pain Using the Sweep Frequency Method
Previous Article in Special Issue
Shear Strength Prediction Equations and Experimental Study of High Strength Steel Fiber-Reinforced Concrete Beams with Different Shear Span-to-Depth Ratios
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Communication

Dynamic Behavior of PET FRP and Its Preliminary Application in Impact Strengthening of Concrete Columns

1
Key Laboratory of Urban Security and Disaster Engineering of Ministry of Education, Beijing University of Technology, Beijing 100124, China
2
Ingram School of Engineering, Texas State University, San Marcos, TX 78667, USA
3
Department of Civil and Environmental Engineering, The Hong Kong Polytechnic University, Hong Kong 999077, China
*
Author to whom correspondence should be addressed.
Submission received: 15 October 2019 / Revised: 13 November 2019 / Accepted: 15 November 2019 / Published: 20 November 2019

Abstract

:
Polyethylene terephthalate (PET) fiber has attracted significant attention for reinforced concrete (RC) structure rehabilitation due to its large rupture strain (LRS; more than 7%) characteristic and recyclability from waste plastic bottles. This study presents a dynamic tensile test of PET fiber bundles performed using a drop-weight impact system. Results showed that the tensile strength and the elastic modulus of the PET fiber bundles increased, whereas the failure strain and the toughness decreased with the increasing strain rate from 1/600 to 160 s−1. In addition, the performance of concrete confined with the PET fiber-reinforced polymer (FRP) under impact loading was investigated based on a 75 mm-diameter split Hopkinson pressure bar (SHPB) device and a drop-weight apparatus. For the SHPB test, owing to the large rupture strain property of PET FRP, the PET FRP-confined concrete exhibited significantly better performance under impact loading compared to its counterpart confined with carbon FRPs (CFRPs). During the drop-weight test, the confinement of the PET FRP composites to the concrete columns as external jackets not only improved the peak impact force, but also prolonged the impact process.

1. Introduction

Fiber-reinforced polymers (FRPs) have been widely used for seismic strengthening of existing reinforced concrete (RC) structures, owing to their advantages of high strength-to-weight ratios, corrosion resistance, and superior durability [1,2,3,4,5,6,7,8,9,10,11,12,13,14]. Considering the fact that the existing RC columns may be subjected to not only seismic loading but also dynamic loading such as vehicle/boat impact during their service life [15], the investigations of impact behaviors of RC structures strengthened with FRP composites are of vital importance for the application of FRPs in the impact-resistant design of RC structures. Although extensive studies of impact-resistant behaviors of conventional concrete and RC structures have been conducted [16,17,18,19,20,21], only a few studies of impact-resistant behaviors of FRP-confined concrete were conducted [22,23,24,25,26,27].
Xiao and Shen [23] conducted the drop-weight test to investigate the impact-resistant behaviors of the concrete-filled steel tube column confined with carbon FRPs (CFRPs) and found that the damage of the specimen could be reduced with the application of CFRPs as external jackets. Huang et al. [26] investigated the impact-resistant behaviors of the glass FRP (GFRP)–SR (spiral reinforcement)-confined concrete columns and found that an increase in the thickness of the GFRP tube led to an increase in the impact-resistant behaviors of the specimen. Yang et al. [27] used a 100 mm-diameter split Hopkinson pressure bar (SHPB) apparatus to investigate the dynamic mechanical behaviors of the concrete confined with aramid FRPs (AFRPs). The experimental results showed that the dynamic compressive strength, ultimate strain, and toughness of the concrete were remarkably increased with the application of the external AFRP jacket to confine the core concrete.
Considering the fact that the FRP mainly bears tensile force in the strengthening of the structures and the fiber bundles are the main load-bearing element in FRP composites, the dynamic tensile mechanical properties of fiber bundles are necessary for studying the failure mechanism between the FRP and the concrete under impact loading. To address this issue, some studies have been reported to date. Ou et al. [28] investigated the strain rate effect on the dynamic tensile mechanical properties of the glass-fiber bundle specimen and found that the tensile strength increased with the increasing strain rate from 1/600 to 160 s−1. Zhu et al. [29] investigated the effect of the strain rate (20 to 100 s−1) on the dynamic tensile mechanical properties of the Kevlar 49 fiber bundle specimen. The experimental results showed that the tensile strength, the elastic modulus, and the toughness increased with the increasing strain rate.
The past decade has witnessed the emergence of a new type of FRP composite, polyethylene terephthalate (PET) [30,31,32,33,34,35,36,37,38,39,40,41,42]. Research has shown that its very large rupture strain (i.e., more than 7%) may lead to enhanced structural ductility and impact energy dissipation in the impact-resistant retrofitting/strengthening of RC structures [43]. This paper briefly presents the authors’ recent studies on the dynamic tensile mechanical properties of PET fiber bundles and the dynamic compressive behavior of concrete confined by the PET FRP. The preliminary results illustrated the great potential of the use of PET FRP in impact strengthening applications of RC structures at the material (i.e., PET fiber bundle and PET FRP-confined concrete) and component (i.e., PET FRP-confined concrete column) levels. It is expected that the results presented here will facilitate further investigation of the impact-resistant behavior of PET FRP-strengthened RC structures.

2. Materials and Methods

2.1. Dynamic Tensile Test of PET Fiber Bundles

A typical specimen was fabricated with a gauge length of 25 mm (Figure 1) according to Ou et al. [28]. A long fiber bundle with a 1800 mm length was extracted from the unidirectional PET fiber fabric and weighed by an electronic balance to obtain a mass of 0.307 g. The linear density (1.7 × 10−3 g/cm) could be calculated by dividing the mass by the length, and the area of the transverse section of the bundle (1.23 × 10−3 cm2) could be obtained by dividing the linear density by the bulk density (1.38 g/cm3) that was provided by the manufacturer (Maeda Kosen Co., Sakai-shi, Japan). A fiber bundle with a length of 60 mm was cut from the extracted long fiber bundle. Two aluminum sheets with a length of 20 mm, a width of 15 mm, and a thickness of 0.2 mm were roughhewed by a serrated steel plate and folded along the long side to catch the fiber bundle using the epoxy resin. After the resin was fully cured and the redundant fiber bundle at both sides was cut off, a fiber bundle specimen with a gauge length of 25 mm was completed.
Five PET fiber bundle specimens were tested for each displacement rate of 1, 2, 3, and 4 m/s with the respective strain rates of 40, 80, 120, and 160 s−1, which is the ratio of the displacement rate to the corresponding gauge length of the specimen, using an Instron drop-weight impact system (Figure 2). The impact height of the system ranged from 0.03 to 1.10 m, and the maximum mass of a drop hammer was 37.5 kg. The drop hammer dropped freely along the guide rail and impacted the specimen after the release of the drop hammer.
For comparison, five PET fiber bundle specimens were also tested under quasi-static conditions at a crosshead speed of 2.5 mm/min (strain rate of 1/600 s−1) using an MTS universal testing machine. The loading capacity of the MTS system ranges from 0.1 to 30 kN with a data sampling rate of 1 kHz. The tension of the PET fiber bundle specimen was measured with a force sensor, of which the maximum range and the data acquisition rate are 1 kN and 20 Hz, respectively. The deformation of the PET fiber bundle specimen was considered as the displacement of the upper beam of the system, due to the fact that the stiffness of the specimen was far lower than that of the loading system [44].

2.2. Split Hopkinson Pressure Bar Test

Concrete cylinders with a diameter of 150 mm and a height of 305 mm were cast with ordinary Portland cement, river sand, and crushed granitic rocks with a particle size ranging from 5 to 10 mm. The average 28-day compressive strength of the concrete was 18.5 MPa.
A total of 9 concrete columns with a 70 mm diameter and a 38 mm height were prepared. Among them, 3 concrete cylinders were wrapped with one layer of the PET FRP, of which the nominal thickness, the tensile strength, and the elastic modulus were 0.841 mm, 751 MPa, and 17.9 GPa, respectively, 3 concrete cylinders were wrapped with two layers of the PET FRP, and 3 specimens were wrapped with one layer of the CFRP, of which the nominal thickness, the tensile strength, and the elastic modulus were 0.165 mm, 4423 MPa, and 240 GPa, respectively, for the purpose of the comparison (Table 1), according to the manual wet layup way [30]. A continuous fiber sheet saturated with the epoxy resin, mixed at a ratio of the main resin component L-500AS to the hardener L-500BS of 2:1 (provided by SANYU Shanghai Company), was wrapped around the concrete cylinder with the fibers orientated in the hoop direction of the cylinder. To prevent the debonding failure, a fiber sheet with a length of 350 mm (i.e., one circumference + half circumference of the overlapping zone) was used for the fabrication of one-layer FRP-confined concrete specimens. To reduce the test scatter, three identical specimens were tested at each impact velocity using a 75 mm-diameter SHPB device to investigate the dynamic compressive behavior of the FRP-confined concrete (Figure 3). The apparatus comprised an energy source, a 600 mm-long projectile, a 5000 mm-long incident bar, a 3000 mm-long transmission bar, a digital oscilloscope, and a velocity testing system that was used to record the initial velocity of the projectile.
The specimen was sandwiched between the incident and transmission bars. The stress wave was reshaped with a rubber shaper (1 mm in thickness and 20 mm in diameter) installed on the impact end of the incident bar. The time histories of the strain ε(t), stress σ(t), and strain rate ε ˙ (t) of the specimen can be obtained by Equations (1)–(3), according to the two-wave theory [27]:
ε ( t ) = 2 C L s 0 t [ ε i ( t ) ε t ( t ) ] d t ,
σ ( t ) = E A A s ε t ( t ) ,
ε ˙ ( t ) = 2 C L s [ ε i ( t ) ε t ( t ) ] ,
where εi(t) and εt(t) are the strain of the incident and transmission bars, respectively; A is the cross-sectional area of bars; As and Ls are the initial cross-sectional area and the height of the specimen, respectively.

2.3. Drop-Weight Test

Twelve concrete cylinders with a diameter of 95 mm, a height of 285 mm, and an average 28-day compressive strength of 58.5 MPa were prepared. The preparation of the concrete column and the fabrication of the FRP-confined concrete column were the same as those presented in Section 2.2. Among them, 8 cylinders were wrapped with one layer of the PET FRP, 2 cylinders were confined with one layer of the AFRP, of which the nominal thickness, the tensile strength, and the elastic modulus are 0.169 mm, 3732 MPa, and 115 GPa, respectively, and 2 remaining unconfined concrete cylinders were tested as control specimens (Table 2). All specimens were denoted as “A-B-C”, where A, B, and C stand for the type of FRP, the number of FRP layers, and the drop height, respectively. Two nominally identical specimens were tested at each drop height to reduce the data scatter.
A large-capacity drop-weight setup was used for the impact test [23], consisting of a hammerhead with a weight of 188 kg, 14 balancing weights each with a weight of 68 kg, a steel frame, a track, a control system, and a lifting device (Figure 4). The maximum drop height was 16 m. Different impact energies can be obtained by adjusting the mass of the drop weight and the drop height. In this test, the drop weight was held the same at 256 kg (the hammerhead + one balancing weight), and different impact energies were achieved by varying the impact height (i.e., 2, 3, 4, and 5 m).

3. Results and Discussion

Figure 5 shows the typical stress–strain curves of the PET fiber bundle specimens at different strain rates. The curves exhibit a bilinear stress–strain relationship and a rapid drop from the peak stress to zero, which indicates a brittle fracture of the PET fiber bundle. The tensile strength, the elastic modulus, the failure strain, and the toughness are sensitive to the strain rate. When the strain rate increased from 1/600 to 160 s−1, there was an increase in the tensile strength, which can be attributed to the fact that there was not enough time for the defects of filaments in the fiber bundle to develop at a high strain rate [45]. The initial elastic modulus and the second elastic modulus (i.e., slopes of the two portions of the stress–strain curve) increased with an increase in the strain rate from 1/600 to 160 s−1. Conversely, there was a decrease in the failure strain and the toughness with the increasing strain rate from 1/600 to 160 s−1. Figure 6 shows the failure modes of the PET fiber bundles at different strain rates. At a low strain rate (e.g., 1/600 s−1), the fracture surface of the fiber bundle had a chaotic appearance with different fracture positions of filaments. At a high strain rate (e.g., 160 s−1), the fiber bundle ruptured with a relatively trim fractography.
Figure 7a shows the failure mode of one layer of the CFRP-confined concrete at a strain rate of 218 s−1 from SHPB tests. At a strain rate of about 220 s−1, one layer of the CFRP-confined concrete was smashed together with the external FRP rupture, whereas, due to its very large rupture strain, two layers of the PET FRP-confined concrete could not be destroyed (Figure 7b). Therefore, to investigate the failure mechanism of the concrete confined with the PET FRP, the specimen was repeatedly impacted under the same impact velocity until failure (Figure 7b). As shown in Figure 7b, only a small piece of the concrete was peeled off the surface of concrete confined with the PET FRP after the second impact with a strain rate of 272 s−1. Under the third impact at a strain rate of 280 s−1, partial concrete was crushed with no rupture of the external PET FRP.
Figure 8 shows the dynamic stress–strain curves of specimens confined with the CFRP and the PET FRP at a strain rate of around 220 s−1. The PET and CFRPs were designed for a comparison based on ultimate jacket strengths (i.e., the product of tensile strength and thickness of FRP jacket). One layer of the CFRP provides an ultimate jacket strength of 729.8 N/mm that falls between the values provided by one layer and two layers of the PET FRPs (631.6 N/mm and 1263.2 N/mm, respectively). The dynamic compressive strength of the specimen confined with one layer of the CFRP was 89.4 MPa, whereas the corresponding value for one layer of the PET FRP-confined concrete was 82.9 MPa with a larger compressive strain of 4.58%. In addition, the dynamic compressive strength and the corresponding strain of two layers of the PET FRP confined-concrete were remarkably higher than those of the CFRP-confined counterpart, indicating the superior impact performance of the PET FRP-confined concrete due to the large rupture strain characteristic.
Figure 9 shows the dynamic compressive stress–strain curves of the specimen confined with two layers of the PET FRP under multiple impacts. The compressive strength of two layers of the PET FRP-confined concrete decreased after the second impact due to the progressive concrete damage, which reveals superior impact-resistant behavior as far as deformability is concerned due to the large rupture strain characteristic.
Figure 10a shows the time histories of specimens with three different confining conditions (i.e., no FRP, one layer of AFRP, and PET FRP) under the same drop height of 2 m from the drop-weight tests. It can be seen that, compared to the unconfined specimen, the application of AFRP led to an increase in the peak impact force. It can also be seen in Figure 10a that the application of PET FRP not only improved the peak impact force, but also prolonged the impact process, leading to a superior impact resistance. Figure 10b shows the time histories of the identical PET FRP-confined specimens tested at different drop heights. As can be seen in Figure 10b, the peak impact force of the specimen slightly increased, and the impact duration gradually decreased with the increasing drop height from 2 to 5 m. It is worth noting that the duration of the specimen impacted under a 4 m drop height was longer than that of the counterpart under a 3 m drop height, which can be considered a test scatter in this study.

4. Conclusions

Based on the dynamic tensile test of PET fiber bundles, the SHPB test, and the drop weight test of the PET FRP-confined concrete, the following conclusions can be drawn:
1. PET fiber bundle is a strain rate-sensitive material. The tensile strength and the elastic modulus increased, whereas the failure strain and the toughness decreased with the increasing strain rate from 1/600 to 160 s−1.
2. Two layers of the PET FRP-confined concrete survived after a single impact compared to its counterpart confined with one layer of the CFRP that can be crushed into pieces under a similar strain rate of about 220 s−1.
3. The dynamic compressive strength of the PET FRP-confined concrete experienced a decrease under multiple impacts with the same impact energy due to the progressive damage of concrete.
4. The application of the PET FRP for the concrete column not only increased the peak impact-resistance force of columns, but also led to a prolonged impact duration.

Author Contributions

J.-F.J., T.O., J.-G.D. and J.-B.J. conceived and designed the experiments; Y.-L.B. and Z.-W.Y. performed the experiment, analyzed the data and wrote the paper; J.-F.J. and T.O. monitored the experimental process; all authors contributed to the authoring of the paper.

Funding

This research was funded by National Key R&D Programs of China (2017YFE0103000) and the National Natural Science Foundation of China (grant numbers: 51778019, 51678014, and 51578030).

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Teng, J.G.; Chen, J.F.; Smith, S.T.; Lam, L. FRP-Strengthened RC Structures; John Wiley & Sons: New York, NY, USA, 2002. [Google Scholar]
  2. Ozbakkaloglu, T.; Jian, C.L.; Vincent, T. FRP-confined concrete in circular sections: Review and assessment of stress–strain models. Eng. Struct. 2013, 49, 1068–1088. [Google Scholar] [CrossRef]
  3. Hollaway, L.C.; Teng, J.G. Strengthening and Rehabilitation of Civil Infrastructures Using Fibre-Reinforced Polymer (FRP) Composites; Woodhead Publishing Ltd.: Cambridge, UK, 2008. [Google Scholar]
  4. Ozbakkaloglu, T.; Saatcioglu, M. Displacement-based model to predict lateral drift capacities of concrete-filled FRP tube columns. Eng. Struct. 2017, 147, 345–355. [Google Scholar] [CrossRef]
  5. Wang, Y.L.; Cai, G.C.; Li, Y.Y.; Waldmann, D.; Larbi, A.S.; Tsavdaridis, K.D. Behavior of Circular Fiber-Reinforced Polymer-Steel-Confined Concrete Columns Subjected to Reversed Cyclic Loads: Experimental Studies and Finite-Element Analysis. J. Struct. Eng. 2019, 145, 04019085. [Google Scholar] [CrossRef]
  6. Wang, G.L.; Dai, J.G.; Bai, Y.L. Seismic retrofit of exterior RC beam-column joints with bonded CFRP reinforcement: An experimental study. Compos. Struct. 2019, 224, 111018. [Google Scholar] [CrossRef]
  7. Guo, Y.C.; Gao, W.Y.; Zeng, J.J.; Duan, Z.J.; Ni, X.Y.; Peng, K.D. Compressive behavior of FRP ring-confined concrete in circular columns: Effects of specimen size and a new design-oriented stress-strain model. Constr. Build. Mater. 2019, 201, 350–368. [Google Scholar] [CrossRef]
  8. Ozbakkaloglu, T.; Saatcioglu, M. Seismic behavior of high-strength concrete columns confined by fiber-reinforced polymer tubes. J. Compos. Constr. 2006, 10, 538–549. [Google Scholar] [CrossRef]
  9. Idris, Y.; Ozbakkaloglu, T. Seismic Behavior of High-Strength Concrete-Filled FRP Tube Columns. J. Compos. Constr. ASCE 2013, 17, 04013013. [Google Scholar] [CrossRef]
  10. Ozbakkaloglu, T.; Idris, Y. Seismic Behavior of FRP-High-Strength Concrete-Steel Double-Skin Tubular Columns. J. Struct. Eng. ASCE 2014, 140, 04014019. [Google Scholar] [CrossRef]
  11. Idris, Y.; Ozbakkaloglu, T. Behavior of square fiber reinforced polymer-high-strength concrete-steel double-skin tubular columns under combined axial compression and reversed-cyclic lateral loading. Eng. Struct. 2016, 118, 307–319. [Google Scholar] [CrossRef]
  12. Wang, Y.L.; Chen, G.P.; Wan, B.L.; Cai, G.C.; Zhang, Y.W. Behavior of circular ice-filled self-luminous FRP tubular stub columns under axial compression. Constr. Build. Mater. 2020, 232, 17287. [Google Scholar] [CrossRef]
  13. Mohammadi, M.; Dai, J.G.; Wu, Y.F.; Bai, Y.L. Development of extended Drucker–Prager model for non-uniform FRP-confined concrete based on triaxial tests. Constr. Build. Mater. 2019, 224, 1–18. [Google Scholar] [CrossRef]
  14. Jiang, J.F.; Li, P.D.; Nisticò, N. Local and global prediction on stress-strain behavior of FRP-confined square concrete sections. Compos. Struct. 2019, 226, 111205. [Google Scholar] [CrossRef]
  15. Ou, Y.F.; Zhu, D.J.; Zhang, H.A.; Yao, Y.M.; Mobasher, B.; Huang, L. Mechanical properties and failure characteristics of CFRP under intermediate strain rates and varying temperatures. Compos. Part B Eng. 2016, 95, 123–136. [Google Scholar] [CrossRef]
  16. Al-Salloum, Y.; Almusallam, T.; Ibrahim, S.M.; Abbas, H.; Alsayed, S. Rate dependent behavior and modeling of concrete based on SHPB experiments. Cem. Concr. Compos. 2015, 55, 34–44. [Google Scholar] [CrossRef]
  17. Grote, D.L.; Park, S.W.; Zhou, M. Dynamic behavior of concrete at high strain rates and pressures: I. experimental characterization. Int. J. Impact Eng. 2001, 25, 869–886. [Google Scholar] [CrossRef]
  18. Chen, X.D.; Wu, S.X.; Zhou, J.K. Compressive Strength of Concrete Cores under High Strain Rates. J. Perform. Constr. Facil. 2015, 29, 06014005. [Google Scholar] [CrossRef]
  19. Zhao, D.B.; Yi, W.J.; Kunnath, S.K. Numerical simulation and shear resistance of reinforced concrete beams under impact. Eng. Struct. 2018, 166, 387–401. [Google Scholar] [CrossRef]
  20. Xie, Z.H.; Duan, Z.J.; Guo, Y.C.; Li, X.; Zeng, J.J. Behavior of Fiber-Reinforced Polymer-Confined High-Strength Concrete under Split-Hopkinson Pressure Bar (SHPB) Impact Compression. Appl. Sci. 2019, 9, 2830. [Google Scholar] [CrossRef]
  21. Ding, Y.; Liu, J.P.; Bai, Y.L. Linkage of multi-scale performances of nano-CaCO3 modified ultra-high performance engineered cementitious composites (UHP-ECC). Constr. Build. Mater. 2020, 234, 117418. [Google Scholar] [CrossRef]
  22. Shan, J.H.; Chen, R.; Zhang, W.X.; Xiao, Y.; Yi, W.J.; Lu, F.Y. Behavior of Concrete Filled Tubes and Confined Concrete Filled Tubes under High Speed Impact. Adv. Struct. Eng. 2007, 10, 209–218. [Google Scholar] [CrossRef]
  23. Xiao, Y.; Shen, Y.L. Impact Behaviors of CFT and CFRP Confined CFT Stub Columns. J. Compos. Constr. 2012, 16, 662–670. [Google Scholar]
  24. Pham, T.M.; Hao, H. Review of concrete structures strengthened with FRP against impact loading. Structures 2016, 7, 59–70. [Google Scholar] [CrossRef]
  25. Pham, T.M.; Hao, H. Axial Impact Resistance of FRP-Confined Concrete. J. Compos. Constr. 2017, 21, 04016088. [Google Scholar] [CrossRef]
  26. Huang, L.; Sun, X.X.; Yan, L.B.; Kasal, B. Impact behavior of concrete columns confined by both GFRP tube and steel spiral reinforcement. Constr. Build. Mater. 2017, 131, 438–448. [Google Scholar] [CrossRef]
  27. Yang, H.; Song, H.W.; Zhang, S. Experimental investigation of the behavior of aramid fiber reinforced polymer confined concrete subjected to high strain-rate compression. Constr. Build. Mater. 2015, 95, 143–151. [Google Scholar] [CrossRef]
  28. Ou, Y.F.; Zhu, D.J.; Zhang, H.A.; Huang, L.; Yao, Y.M.; Li, G.S.; Mobasher, B. Mechanical Characterization of the Tensile Properties of Glass Fiber and Its Reinforced Polymer (GFRP) Composite under Varying Strain Rates and Temperatures. Polymers 2016, 8, 196. [Google Scholar] [CrossRef]
  29. Zhu, D.; Mobasher, B.; Erni, J.; Bansal, S.; Rajan, S.D. Strain rate and gage length effects on tensile behavior of Kevlar 49 single yarn. Compos. Part A Appl. Sci. Manuf. 2012, 43, 2021–2029. [Google Scholar] [CrossRef]
  30. Dai, J.G.; Bai, Y.L.; Teng, J.G. Behavior and Modeling of Concrete Confined with FRP Composites of Large Deformability. J. Compos. Constr. 2011, 15, 963–973. [Google Scholar] [CrossRef]
  31. Bai, Y.L.; Dai, J.G.; Mohammadi, M.; Lin, G.; Mei, S.J. Stiffness-based design-oriented compressive stress-strain model for large-rupture-strain (LRS) FRP-confined concrete. Compos. Struct. 2019, 223, 110953. [Google Scholar] [CrossRef]
  32. Bai, Y.L.; Dai, J.G.; Teng, J.G. Cyclic Compressive Behavior of Concrete Confined with Large Rupture Strain FRP Composites. J. Compos. Constr. 2014, 18, 04013025. [Google Scholar] [CrossRef]
  33. Dai, J.G.; Lam, L.; Ueda, T. Seismic retrofit of square RC columns with polyethylene terephthalate (PET) fibre reinforced polymer composites. Constr. Build. Mater. 2012, 27, 206–217. [Google Scholar] [CrossRef]
  34. Saleem, S.; Hussain, Q.; Pimanmas, A. Compressive Behavior of PET FRP–Confined Circular, Square, and Rectangular Concrete Columns. J. Compos. Constr. 2017, 21, 04016097. [Google Scholar] [CrossRef]
  35. Bai, Y.L.; Dai, J.G.; Teng, J.G. Monotonic Stress-Strain Behavior of Steel Rebars Embedded in FRP-Confined Concrete Including Buckling. J. Compos. Constr. 2017, 21, 04017043. [Google Scholar] [CrossRef]
  36. Bai, Y.L.; Dai, J.G.; Teng, J.G. Buckling of steel reinforcing bars in FRP-confined RC columns: An experimental study. Constr. Build. Mater. 2017, 140, 403–415. [Google Scholar] [CrossRef]
  37. Bai, Y.L.; Dai, J.G.; Ozbakkaloglu, T. Cyclic stress-strain model incorporating buckling effect for steel reinforcing bars embedded in FRP-confined concrete. Compos. Struct. 2017, 182, 54–66. [Google Scholar] [CrossRef]
  38. Anggawidjaja, D.; Ueda, T.; Dai, J.; Nakai, H. Deformation capacity of RC piers wrapped by new fiber-reinforced polymer with large fracture strain. Cem. Concr. Compos. 2006, 28, 914–927. [Google Scholar] [CrossRef]
  39. Ispir, M. Monotonic and Cyclic Compression Tests on Concrete Confined with PET-FRP. J. Compos. Constr. 2014, 19, 04014034. [Google Scholar] [CrossRef]
  40. Huang, L.; Zhang, S.S.; Yu, T.; Wang, Z.Y. Compressive behaviour of large rupture strain FRP-confined concrete-encased steel columns. Constr. Build. Mater. 2018, 183, 513–522. [Google Scholar] [CrossRef]
  41. Bai, Y.L.; Yan, Z.W.; Ozbakkaloglu, T.; Han, Q.; Dai, J.G.; Zhu, D.J. Quasi-static and dynamic tensile properties of large-rupture-strain (LRS) polyethylene terephthalate fiber bundle. Constr. Build. Mater. 2020, 232, 117241. [Google Scholar] [CrossRef]
  42. Zeng, J.J.; Gao, W.Y.; Duan, Z.J.; Bai, Y.L.; Guo, Y.C.; Ouyang, L.J. Axial compressive behavior of polyethylene terephthalate/carbon FRP-confined seawater sea-sand concrete in circular columns. Constr. Build. Mater. 2020, 234, 117383. [Google Scholar] [CrossRef]
  43. Kurihashi, Y.; Mikami, H.; Komuro, M.; Kishi, N. Effect of sheet volume on impact resistant capacity of RC beam strengthened with AFRP sheet. In Proceedings of the 8th Inernational Conference on Fiber-Reinforced Polymer (FRP) Composites in Civil Engineering (CICE 2016), Hong Kong, China, 14–16 December 2016. [Google Scholar]
  44. Ou, Y.F.; Zhu, D.J. Tensile behavior of glass fiber reinforced composite at different strain rates and temperatures. Constr. Build. Mater. 2015, 96, 648–656. [Google Scholar] [CrossRef]
  45. Ou, Y.F.; Zhu, D.J.; Huang, M.Y.; Li, H. The effects of gage length and strain rate on tensile behavior of Kevlar (R) 29 single filament and yarn. J. Compos. Mater. 2017, 51, 109–123. [Google Scholar] [CrossRef]
Figure 1. Schematic diagram of a fiber bundle specimen.
Figure 1. Schematic diagram of a fiber bundle specimen.
Applsci 09 04987 g001
Figure 2. Instron drop-weight impact system.
Figure 2. Instron drop-weight impact system.
Applsci 09 04987 g002
Figure 3. Split Hopkinson pressure bar (SHPB) apparatus.
Figure 3. Split Hopkinson pressure bar (SHPB) apparatus.
Applsci 09 04987 g003
Figure 4. Drop-weight test setup.
Figure 4. Drop-weight test setup.
Applsci 09 04987 g004
Figure 5. Tensile stress–strain curves of the PET fiber bundle at different strain rates.
Figure 5. Tensile stress–strain curves of the PET fiber bundle at different strain rates.
Applsci 09 04987 g005
Figure 6. SEM images of failure modes at the strain rates of 1/600 s−1 (a); 40 s−1 (b); 80 s−1 (c); 120 s−1 (d); 160 s−1 (e).
Figure 6. SEM images of failure modes at the strain rates of 1/600 s−1 (a); 40 s−1 (b); 80 s−1 (c); 120 s−1 (d); 160 s−1 (e).
Applsci 09 04987 g006
Figure 7. Failure modes of the concrete confined with the CFRP (a) and the PET FRP (b).
Figure 7. Failure modes of the concrete confined with the CFRP (a) and the PET FRP (b).
Applsci 09 04987 g007
Figure 8. Comparison of the dynamic compressive stress–strain curves of the specimen at a strain rate of around 220 s−1.
Figure 8. Comparison of the dynamic compressive stress–strain curves of the specimen at a strain rate of around 220 s−1.
Applsci 09 04987 g008
Figure 9. Dynamic compressive stress–strain curves of the specimen confined with two layers of the PET FRP under multiple impacts.
Figure 9. Dynamic compressive stress–strain curves of the specimen confined with two layers of the PET FRP under multiple impacts.
Applsci 09 04987 g009
Figure 10. Impact force time histories of the FRP-confined concrete with different confining conditions (a) and different drop heights (b).
Figure 10. Impact force time histories of the FRP-confined concrete with different confining conditions (a) and different drop heights (b).
Applsci 09 04987 g010
Table 1. Summary of specimens for the SHPB test.
Table 1. Summary of specimens for the SHPB test.
Type of TestD × H (mm)Type of FRPNominal Thickness of FRP (mm)Volume Fraction of FiberTensile Strength of FRP (MPa)Number of LayersInitial Velocity (m/s)Unconfined Concrete Strength (MPa)Number of Identical Specimen
SHPB test70 × 38Carbon FRP (CFRP)0.16515%4423110.918.53
70 × 38Polyethylene terephthalate (PET) FRP0.84131%751111.418.53
70 × 38PET FRP0.84131%751211.118.53
Table 2. Summary of specimens for the drop-weight impact test.
Table 2. Summary of specimens for the drop-weight impact test.
Type of TestD × H (mm)Type of FRPNominal Thickness of FRP (mm)Volume Fraction of FiberTensile Strength of FRP (MPa)Number of LayersImpact Height (m)Unconfined Concrete Strength (MPa)Number of Identical Specimen
Drop-weight test95 × 285-----258.52
95 × 285AFRP0.16919%37321258.52
95 × 285PET FRP0.84131%7511258.52
95 × 285PET FRP0.84131%7511358.52
95 × 285PET FRP0.84131%7511458.52
95 × 285PET FRP0.84131%7511558.52

Share and Cite

MDPI and ACS Style

Bai, Y.-L.; Yan, Z.-W.; Ozbakkaloglu, T.; Dai, J.-G.; Jia, J.-F.; Jia, J.-B. Dynamic Behavior of PET FRP and Its Preliminary Application in Impact Strengthening of Concrete Columns. Appl. Sci. 2019, 9, 4987. https://0-doi-org.brum.beds.ac.uk/10.3390/app9234987

AMA Style

Bai Y-L, Yan Z-W, Ozbakkaloglu T, Dai J-G, Jia J-F, Jia J-B. Dynamic Behavior of PET FRP and Its Preliminary Application in Impact Strengthening of Concrete Columns. Applied Sciences. 2019; 9(23):4987. https://0-doi-org.brum.beds.ac.uk/10.3390/app9234987

Chicago/Turabian Style

Bai, Yu-Lei, Zhi-Wei Yan, Togay Ozbakkaloglu, Jian-Guo Dai, Jun-Feng Jia, and Jun-Bo Jia. 2019. "Dynamic Behavior of PET FRP and Its Preliminary Application in Impact Strengthening of Concrete Columns" Applied Sciences 9, no. 23: 4987. https://0-doi-org.brum.beds.ac.uk/10.3390/app9234987

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop