Next Article in Journal
Reliability and Validity of the Malay Mindful Eating Questionnaire (MEQ-M) among Overweight and Obese Adults
Next Article in Special Issue
Sinus Floor Elevation via an Osteotome Technique without Biomaterials
Previous Article in Journal
Treatment of Stage 2 Medication-Induced Osteonecrosis of the Jaw: A Case Series
Previous Article in Special Issue
Clinical Efficacy of Mesenchymal Stem Cells in Bone Regeneration in Oral Implantology. Systematic Review and Meta-Analysis
Open AccessReview

Digital Impressions in Implant Dentistry: A Literature Review

1
Porto Dental Institute, 4150-518 Porto, Portugal
2
Faculty of Health Sciences, Fernando Pessoa University, 4249-004 Porto, Portugal
3
Department of Periodontology, Universidad de Sevilla, 41009 Seville, Spain
*
Author to whom correspondence should be addressed.
Int. J. Environ. Res. Public Health 2021, 18(3), 1020; https://0-doi-org.brum.beds.ac.uk/10.3390/ijerph18031020
Received: 27 December 2020 / Revised: 15 January 2021 / Accepted: 20 January 2021 / Published: 24 January 2021
(This article belongs to the Special Issue Impact of Dental Implants on Oral Health)
Introduction. Digital impressions in implant dentistry rely on many variables, and their accuracy, particularly in complete edentulous patients, is not well understood. Aim. The purpose of this literature review was to determine which factors may influence the accuracy of digital impressions in implant dentistry. Emphasized attention was given to the design of the intra-oral scan body (ISB) and scanning techniques. Materials and methods. A Medline, PubMed and EBSCO Host databases search, complemented by a hand search, was performed in order to select relevant reports regarding the appliance of digital impressions in implant dentistry. The search subject included but was not limited to accuracy of digital impressions in implant dentistry, digital scanning techniques, the design and material of the ISBs, and the depth and angulation of the implant. The related titles and abstracts were screened, and the remaining articles that fulfilled the inclusion criteria were selected for full-text readings. Results. The literature search conducted for this review initially resulted in 108 articles, among which only 21 articles fulfilled the criteria for inclusion. Studies were evaluated according to five subjects: accuracy of digital impressions in implant dentistry; the design and material of the intra-oral scan bodies; scanning technique; the influence of implants depth/angulations on the digital impression and accuracy of different intra-oral scanner devices. Conclusions. The accuracy of digital impressions in implant dentistry depends on several aspects. The depth/angulation of the implant, the experience of the operator, the intra-oral scanner used, and environmental conditions may influence the accuracy of digital impressions in implant dentistry. However, it seems that ISBs’ design and material, as well as scanning technique, have a major impact on the trueness and precision of digital impressions in implant dentistry. Future research is suggested for the better understanding of this subject, focusing on the optimization of the ISB design and scanning protocols. View Full-Text
Keywords: digital impressions; implant dentistry; intra-oral scan bodies; intra-oral scanner; accuracy; scanning technique; implant depth; implant angulation digital impressions; implant dentistry; intra-oral scan bodies; intra-oral scanner; accuracy; scanning technique; implant depth; implant angulation
Show Figures

Figure 1

MDPI and ACS Style

Marques, S.; Ribeiro, P.; Falcão, C.; Lemos, B.F.; Ríos-Carrasco, B.; Ríos-Santos, J.V.; Herrero-Climent, M. Digital Impressions in Implant Dentistry: A Literature Review. Int. J. Environ. Res. Public Health 2021, 18, 1020. https://0-doi-org.brum.beds.ac.uk/10.3390/ijerph18031020

AMA Style

Marques S, Ribeiro P, Falcão C, Lemos BF, Ríos-Carrasco B, Ríos-Santos JV, Herrero-Climent M. Digital Impressions in Implant Dentistry: A Literature Review. International Journal of Environmental Research and Public Health. 2021; 18(3):1020. https://0-doi-org.brum.beds.ac.uk/10.3390/ijerph18031020

Chicago/Turabian Style

Marques, Simone; Ribeiro, Paulo; Falcão, Carlos; Lemos, Bernardo F.; Ríos-Carrasco, Blanca; Ríos-Santos, José V.; Herrero-Climent, Mariano. 2021. "Digital Impressions in Implant Dentistry: A Literature Review" Int. J. Environ. Res. Public Health 18, no. 3: 1020. https://0-doi-org.brum.beds.ac.uk/10.3390/ijerph18031020

Find Other Styles
Note that from the first issue of 2016, MDPI journals use article numbers instead of page numbers. See further details here.

Article Access Map by Country/Region

1
Search more from Scilit
 
Search
Back to TopTop